You are on page 1of 132

BTicino SpA

Viale Borri, 231

www.bticino.com
21100 Varese - Italy

BTicino SpA reserves at any time the right to modify the contents of this booklet and to
communicate, in any form and modality, the changes brought to the same. AD-EXOD15SAG/GB - Version 07/2015
GUEST ROOM
Guide for design and installation
MANAGEMENT SYSTEM

TECHNOLOGY
WITH SCS-BUS
INTEGRATED SOLUTIONS
BTicino offers a specific system
solution for all needs.
GUEST ROOM Designed to guarantee the best
MANAGEMENT SYSTEM welcoming and control service without
overlooking the environmental
A complete aspect, Guest Room Management

range meeting System brings together two aspects:


the supervision, managed by Hotel
all specific needs personnel, and the management of the
room by the Customer. Two separate
worlds, that are however in constant
communication.

2
Contents

4-5
Numerical index Index by item code - page of reference 4

6-21
General A solution for hotels 6
features The functions in the room 8
The supervision: the management of the common areas 10
The system components 12
Integration with solutions of other brands 14
Customisation of the offer: Air, Axolute and Livinglight 16
The customisation of cover plates, key cards and glass controls 18

22-32
General rules Configuration 22
for installation “Hotelsupervision” supervision software 23
Maximum distances and absorptions 24
Typical hotel system 28

33-45
Installation and Typical wiring diagram for hotel room and common areas 34
configuration Variations of room diagrams 40
Procedure for starting a system 44

46-71
Catalogue Axolute 48
Dimensional data 59
Livinglight 60
Dimensional data 71

72-127
Technical Sheets Technical and dimensional data, standards, mounting and installation 74

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 3


WWW.BTICINO.COM
Numerical index

Item Technical sheet page Catalogue page Item Technical sheet page Catalogue page
3475 51 - 63 F416U1 53 - 65
3476 51 - 63 F418 53 - 65
3477 118 55 - 67 F418U2 53 - 65
3510 55 - 67 F420 100 49 - 61
3511 55 - 67 F428 108 55 - 67
3512 55 - 67 F429 53 - 65
3513 55 - 67 F430/2 54 - 66
3515 55 - 67 F430/4 54 - 66
3541 50 - 62 F430R3V10 54 - 66
3542 50 - 62 F430R8 54 - 66
3547 49 - 61 F430V10 54 - 66
336904 126 56 - 68 F458 102 49 - 61
346020 76 F459 49 - 61
348402 49 - 61 FC2A4/230N 58 - 70
3501/0 56 - 68 FC2A4/24N 58 - 70
3501/1 56 - 68 FC3A4/230N 58 - 70
3501/2 56 - 68 FC4A4/230N 58 - 70
3501/3 56 - 68 FC4A4/24N 58 - 70
3501/4 56 - 68 FC4A6/230N 58 - 70
3501/5 56 - 68 FC4A6/24N 58 - 70
3501/6 56 - 68 FT1A1N230M 58 - 70
3501/7 56 - 68 FT1A1N230S 58 - 70
3501/8 56 - 68 FT1A1N24S 58 - 70
3501/9 56 - 68 FT1A2N230 58 - 70
3501/AMB 56 - 68 FT1A2N230M 58 - 70
3501/AUX 56 - 68 FT1A2N230S 58 - 70
3501/CEN 56 - 68 FT1A2N24 58 - 70
3501/GR 56 - 68 FT1A2N24M 58 - 70
3501/OFF 56 - 68 FT1A2N24S 58 - 70
3501/OI 56 - 68 FT1AC1N230 58 - 70
3501/ON 56 - 68 FT1AC1N24 58 - 70
3501/PUL 56 - 68 FT1C2N230 58 - 70
3501/SLA 56 - 68 FT2A3N230 58 - 70
3501/T 56 - 68 FT2A4N230 58 - 70
3501/TM 56 - 68 FT2A4N230M 58 - 70
3501K 56 - 68 FT2A4N24 58 - 70
3501K/1 56 - 68 FT2AC2N230 58 - 70
3510M 55 - 67 FT2C4N230 58 - 70
3510PB 55 - 67 H4372V230H 57
3544SW 49 - 61 H4548 57
3546SW 49 - 61 H4549 57
BMDI1001 53 -65 H4648 80 49
BMDI1002 52 - 64 H4649 77 49
BMSW1002 52 - 64 H4650 86 49
BMSW1003 52 - 64 H4651 89 49
BMSW1005 52 - 64 H4651M2 50
E46ADCN 75 55 - 67 H4652 93 50
E49 74 55 - 67 H4652/2 50
F401 51 - 63 H4652/3 50
F411/1NC 52 - 64 H4653 83 49
F411/4 52 - 64 H4660M2 50
F411U1 52 - 64 H4661M2 51
F411U2 52 - 64 H4671/1 51
F413N 53 - 65 H4671M2 51
F414 53 - 65 H4678 51

4
Item Technical sheet page Catalogue page Item Technical sheet page Catalogue page
H4691 106 54 L4547 69
HC4033 57 L4551 69
HC4177 57 L4651M2 62
HC4285C 57 L4652/2 62
HC4285C2 57 L4652/3 62
HC4547 57 L4669 125 56 - 68
HC4657M3 50 L4669/500 125 56 - 68
HC4657M4 50 L4669HF 127 56 - 68
HC4680 50 L4669KM1 56 - 68
HC4915BL 57 L4671/1 63
HC4915DD 57 L4678 63
HC4915M2BL 57 L4680 62
HC4915M2DD 57 L4915DD 69
HC4915MR 57 L4915M2DD 69
HC4921BL 57 L4915MR 69
HC4921DD 57 L4915SETBL 69
HC4921M2BL 57 L4915TN 69
HC4921MR 57 LN4548 69
HD4033 57 LN4549 69
HD4177 57 LN4648 80 61
HD4285C 57 LN4649 77 61
HD4285C2 57 LN4650 86 61
HD4547 57 LN4651 89 61
HD4657M3 50 LN4652 93 62
HD4657M4 50 LN4653 84 61
HD4680 50 LN4660M2 62
HD4915BL 57 LN4661M2 63
HD4915DD 57 LN4671M2 63
HD4915M2BL 57 LN4691 106 66
HD4915M2DD 57 MH201 96 49 - 61
HD4915MR 57 69
HD4921BL 57 69
HD4921DD 57 N4373H 69
HD4921M2BL 57 N4547 69
HD4921MR 57 N4551 69
HS4033 57 N4680 62
HS4177 57 N4915DD 69
HS4285C 57 N4915M2DD 69
HS4285C2 57 N4915MR 69
HS4547 57 N4915SETBL 69
HS4657M3 50 N4915TN 69
HS4657M4 50 NT4033 69
HS4680 50 NT4177 69
HS4915BL 57 NT4373H 69
HS4915DD 57 NT4547 69
HS4915M2BL 57 NT4551 69
HS4915M2DD 57 NT4680 62
HS4915MR 57 NT4915DD 69
HS4921BL 57 NT4915M2DD 69
HS4921DD 57 NT4915MR 69
HS4921M2BL 57 NT4915SETBL 69
HS4921MR 57 NT4915TN 69
L4033 69
L4177 69
L4373H 69

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 5


WWW.BTICINO.COM
01

02
03
04

INSIDE THE ROOM IN THE COMMON AREAS FOR CUSTOMERS

01 02

Access control CCTV


From access control Temperature management Temperature management
to home automation, (heating and cooling) (heating and cooling)
BTicino offers all the Lighting control Access control
technological solutions Automation management Lighting control
for the hotel sector Structured cabling devices Automation management
Traditional devices Sound system
(energy sockets, etc...) Data network management
Traditional devices
(energy sockets, etc...)

6
A
SOLUTION
FOR HOTELS
Specific GUEST ROOM MANAGEMENT

products and MANAGEMENT OF THE COMMON AREAS (HALL,


RECEPTION, CORRIDORS, CUCINE, CONFERENCE
systems for ROOMS, ETC…)

the various SUPERVISION OF THE HOTEL FROM THE RECEPTION


USING SPECIFIC SOFTWARE
areas INTEGRATION OF THE SCS-BUS SYSTEM WITH SOLUTIONS
AND SYSTEMS OF OTHER BRANDS

AT THE RECEPTION IN THE REST OF THE BUILDING

03 04

THE SOFTWARE Energy transformation CCTV


PROVIDES: Energy distribution Access control
Supervision and management Service continuity (UPS) Lighting control
of functions installed in the Energy management (measurement) Automation management
hotel VDI (video data) infrastructure
Control and management of Temperature management
the functions inside the rooms (heating and cooling).
and the common areas
Management of the room
status (free, occupied,
customer present, etc.)
Access control management:
programming of key cards and
saving of accesses
Management of bookings
using specific software (PMS)
GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 7
WWW.BTICINO.COM
DND AND MUR DND AND MUR CONTROL:
NOTIFICATIONS: DND (do not disturb)
DND (do not disturb) MUR (make up the room)
MUR (make up the room)

DIGITAL THERMOSTAT UP TO

SAVINGS

IMMEDIATE COMFORT
Thanks to the new MyHOME devices
- 8-key control (customisable)
- digital thermostat,
installed at the side of the bed,
with one single touch it is possible
to create the desired atmosphere,
8-KEY CONTROL adjusting the light, the temperature,
and the shutters.
8
UP TO
30%
SAVINGS
COMFORT RESPECT SAFETY
MANAGEMENT OF USERS OF THE ENVIRONMENT Thanks to the RFDI
Guest Room Management System ENERGY MANAGEMENT technological devices,
enables the customer to be perfectly Guest Room Management System maximum safety in the control
in tune with the room, thanks to gives the hotel establishment of accesses to rooms and other
a range of devices used to create the possibility of reducing energy zones.
the desired atmosphere as far as consumptions thanks to the possibility
lights, music, and temperature are of disabling the devices inside the
concerned. room when the customer is absent.

ENTERTAINMENT SAFETY AT THE TOP


A range of products dedicated to Protected shaver socket, step
Audio/ Video connections, to the marker lamps for the night, and
recharge of technological devices bathroom pull cords. Guarantee of
(Smart-phone, Tablet, etc.), and maximum safety at any time during
to the transmission of Wi-Fi data, the stay.
enables to provide the desired level of
entertainment and enjoyment.

A/V SOCKETS USB CHARGER STEP MARKER LAMPS KEY CARD READER
SOCKET OUTSIDE THE DOOR

THE FUNCTIONS
IN THE
ROOM
Guest Room Management System is a solution
for the management and supervision of hotel and
welcoming establishments. Designed to guarantee
the best welcoming and control service without
overlooking the environmental aspect, Guest Room
Management System brings together two aspects:
The complete system, the supervision, managed by Hotel personnel, and
for maximum efficiency the management of the room by the Customer.
Two separate worlds, that are however in constant
of the whole hotel irrespective communication.
of the technology selected

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 9


WWW.BTICINO.COM
ROOM ROOM

ROOM ROOM

HALL

RECEPTION

THE SUPERVISION:
the management
ROOMS
of the
and the COMMON AREAS
10
The Guest Room
Management System
offer gives the
possibility of supervising
and controlling in real
time the status of the
rooms, and interact
with them.
Using the supervision software
installed in the PC of the
reception, it is possible to
interact with the following room
parameters:
Presence of guests
Temperature display and modification
of the adjustment values
Programmed scenario activation
Alarm notifications and management of the
contacts (window, door, ...)

The software gives the possibility of managing


and programming the key cards with RFID
(Mifare) technology for access to rooms and
common areas.

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 11


WWW.BTICINO.COM
THE MAIN SYSTEM COMPONENTS

SOLUTION

In the corridor - outside the door

KEY CARD READER KEY CARD DND - MUR NOTIFICATIONS


RFID (Mifare classic ISO14443) RFID (Mifare classic ISO14443 DND (do not disturb)
technology, with type A) technology, credit card MUR (make up the room), and
DND (do not disturb) and format, for access to the bell pushbutton
MUR (make up the room) rooms
notifications, and
bell pushbutton

Inside the room

DND AND MUR CONTROL KEY CARD SWITCH DIGITAL THERMOSTAT 8-KEY CONTROL
DND (do not disturb) with possibility of RFID to set and adjust the to recall the scenarios
MUR (make up the room) technology recognition, temperature simply and (lighting, automation,
for the activation of the intuitively inside the room. climate, ...) inside the
functions inside the room.
room

12
At the room switchboard

IP SCENARIO MODULE DIN MODULAR DEVICES


manages and saves the scenarios (max. 50) for management of the functions inside the
of the room or common zone, and acts as rooms
interface with the rest of the system and the
functions of the Hotel.
It connects to the rest of the hotel using the
Ethernet network (RJ45).

At the reception

SUPERVISION SOFTWARE
Using one or more PC, it is possible to control
the status of the rooms with the corresponding
notifications, and manage the available functions. The
software also perform functions connected with the
programming of the key cards.
2 types of license available: KEY CARD PROGRAMMER
Management of up to 20 rooms or common areas to connect to the reception
Management of over 20 rooms or common areas PC through USB connection.
The key cards must have the following features:
RFID Mifare classic ISO14443 type A

IP SERVER
to be used in systems with over
100 rooms or common zones
(over 100 MH201 installed).

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 13


WWW.BTICINO.COM
INTEGRATION
WITH
SOLUTIONS
OF
OTHER BRANDS
SPECIFIC DRIVER

DRIVER

SCS-BUS SYSTEM DRIVER MANAGER

F459

14
BTicino has developed and The DRIVER MANAGER device
The SCS-BUS solution
makes available the new DRIVER can interface the SCS-BUS
can be integrated with MANAGER integration platform, system with the systems of other
systems and products based on the F459 device and on brands by means of specific
of other brands. various drivers. drivers tested in collaboration
It can manage systems or with the various companies.
products of other brands. Contact the System Integration
It is now possible, by means of Service to check the feasibility
the SCS-BUS devices to control, of specific integrations and to
for example, the VRV, VRF and request the licence needed to
air conditioning systems of the use the Driver manager (Toll free
main producers on the market. number 800.837035)

OTHER BRAND SOLUTIONS EXAMPLES

TEMPERATURE CONTROL

AUTOMATION

SECURITY

SAFETY

OTHER
Mitsubishi Electric
VRF City Multi system

Hitachi
VRF system

For more information please contact the System Integration Service (Toll free number 800.837035)

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 15


WWW.BTICINO.COM
CUSTOMISATION

Several shapes and


materials to conceive
and design your Hotel. and

Thermostat
completed with the Axolute
square cover plate
Shaver socket available
in three colours: white, tech and anthracite.
The tech version is used together with the Axolute Air.
16
OF THE OFFER

and

Countless finishes in the


versions: Living International,
Round, Square and Air.

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 17


WWW.BTICINO.COM
CUSTOMISATION
OF
COVER PLATES,
KEY CARDS
AND
GLASS CONTROLS
To further improve the aesthetic value
of the offer, it is possible to customise
both the cover plates and the key cards
with the logo of the Hotel.

White key card switch


with Livinglight Air
cover plate.
Excelsium
Hotel
Excelsium
Hotel

Anthracite 8-key control used


with the Axolute cover plate
Excelsium
Hotel

Excelsiu
m
Hotel

Key card switch available in three


colours: white, tech and anthracite.
The tech version is used together with
the Axolute elliptical cover plate.

Key card customisation

18
The glass controls can be
customised with symbols by
means of silk screen printing

White glass control


with 6 capacitive touch keys.

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 19


WWW.BTICINO.COM
20
Contents
22-32
General rules for Configuration 22
installation “Hotelsupervision” supervision software 23
Maximum distances and absorptions 24
Typical hotel system 28

33-45
Installation and Typical wiring diagram for hotel room and common areas 34
configuration Variations of room diagrams 40
Procedure for starting a system 44

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 21


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

PERFORMANCE AND CONFIGURATION

The hotel supervision system must be


installed in a dedicated LAN network or
in a dedicated VLAN

SYSTEM PERFORMANCE:
Number of zones (rooms and common areas)
which can be made = 500 MAX.
Number of supervision PC which can be installed
= 10 MAX
Install only one MH201 per zone
(room or common area).
Install only one F458 IP server on the same network
Install up to 9 thermostats, 8 outside-door readers
and one key card switch per room or common area.

DEVICE CONFIGURATION:
The IP Server F458 devices and the MH201 IP scenario
module must be configured using the MyHOME_Suite
software, which can be downloaded free of charge
from the website:
www.homesystems-legrandgroup.com.

While all the other devices in SCS-BUS technology can


be configured in two different modes:

- Physical configuration
This is completed using the green and blue
configurators, which must be connected to the
appropriate sockets found on the devices.

- Software configuration PHYSICAL CONFIGURATION

This is performed using a PC with the appropriate


MyHOME_Suite application installed. This solution has
the advantage of offering many more options when
compared with the physical configuration.

The software can be downloaded free of charge


from the website:
www.homesystems-legrandgroup.com

Download the software


free of charge
(QR code)

SOFTWARE CONFIGURATION

22
“Hotelsupervision” SUPERVISION SOFTWARE

The HotelSupervision software has been purposely The software can be activated using two types of
designed for the management and supervision of the hotels. license:
All the management operations can be performed from
reception, from where it is possible to have a complete view 3544SW
of what happens in the individual rooms and the common Management and supervision of up to 20 rooms
areas. or common areas

Some functions: 3546SW


Presence of guest display. Management and supervision of over 20 rooms or
Temperature management with direct control of common areas
thermostats, but giving guests the possibility of
adjusting the temperature within the set limits.
The software can be downloaded from the website:
Key card management with the possibility of limiting
access to certain areas of the hotel and monitoring of www.homesystems-legrandgroup.com/
movements using each key card. BtHomeSystems/productDetail.action?productId=003
Control of different types of alarms and notifications
from rooms or common areas.
Control of DND or MUR type notifications
Download the
(do not disturb and make up room). desired version of
The use of different icons and colours helps the operator the HotelSupervision
to immediately identify the status of the room. software
(QR code)

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 23


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

MAXIMUM DISTANCES AND ABSORPTIONS

In this chapter you will find all the During sizing comply with the
details for correct installation of an following rules:
SCS BUS system:
SELV classification
Maximum distances and 1 THE CONNECTION LENGTH BETWEEN THE POWER SUPPLY AND THE
absorptions FURTHEST DEVICE MUST NOT EXCEED 250 m.
Maximum number of
configurable devices
Power supply
For the purpose of the above
calculations, refer to the
Device
TECHNICAL DATA found in the
chapter TECHNICAL SHEETS.
Length of connection
to the furthest device
In calculating the absorption it
will be necessary to also consider Junction box
the current available based on the
length of the cable.

SELV classification
The Automation system belongs to
the SELV (Safety Extra Low Voltage)
class, as it is powered with double
safety insulation independent
devices not connected to the ground,
and has a maximum operating
voltage of 27 Vdc, in accordance
with CEI EN 60065; it therefore
can be compared to a SELV source
as described at point 411.125 of 2 THE TOTAL LENGTH OF THE CONNECTIONS MUST NOT EXCEED 500 m
(CABLE EXTENDED).
CEI 64-8-4. Compliance with SELV
classification is only guaranteed
subject to full compliance with
current installation regulations,
and with the general installation Power supply
regulations for the individual devices
and cables making up the system Device
outlined by BTicino.
Connections

Junction box

Maximum distances of the


BUS cable and absorptions
The maximum number of devices
that can be connected to the BUS
depends on the total absorption of
the same and the distance between
the point of connection and the
power supply. The power supply can
supply up to 1200 mA or 600 mA;
the maximum number of devices
that can be installed will therefore
depend on the sum of their
individual absorptions.

24
3 FOR OPTIMUM DIVISION OF THE CURRENTS ON THE BUS LINE IT IS RECOMMENDED
THAT THE POWER SUPPLY IS INSTALLED IN AN INTERMEDIATE POSITION.

ON ON

OFF OFF

A PRI

A
E49
PRI: 220 – 240 V~
185 – 175 mA
50/60 Hz
SCS: 27 Vdc
600 mA

B SCS B
E46ADCN
E49
1 2 3 4 5 1 2 3 4 5
1 2 3 4 5 1 2 3 4 5

C1 C2 C3 C4 C1 C2 C3 C4

With power supply E46ADCN: With power supply E49:


A = 250 m max A = 250 m max
B = 250 m max B = 250 m max
A + B = 500 m A + B = 500 m

Maximum current provided by Maximum current provided by


the power supply: 1200 mA. the power supply: 600 mA.

NOTE: If a UTP5 cable is used in alternative to the L4669 BUS cable, distances are halved.

automation

FOR MORE INFORMATION ON THE DESIGN AND


INSTALLATION OF THE SCS-BUS SOLUTIONS SEE THE
SPECIFIC MyHOME TECHNICAL GUIDE
www.catalogo-sfogliabile.bticino.it/myhomegb/
DESIGN AND
INSTALLATION
GUIDE

Consult the MyHOME


specific catalogue
(QR code)

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 25


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

MAXIMUM DISTANCES AND ABSORPTIONS

Maximum distances for the EXAMPLE OF CONNECTION WITH ITEM F411U1


connection of actuators
N
based on the load L
In order to correctly manage certain
types of loads, it is necessary to
comply with some installation
requirements, applicable to all the
actuators used. 1 2 3 L N
Fluorescent lamps: the length of MIN 3 m
the connection cable between the
actuator and the load must not be
less than 3 m. Do not connect more
than 15 actuators controlling this
type of lamps to the same line.
Metal halide and sodium vapour
WARNING: Refer to the technical data listed in the technical
lamps: in addition to the indications sheets for each actuator.
provided for fluorescent lamps, also
pay attention to the instructions for line and the power line for these balancing of the phases, and the
use for these lamps (for example types of lamps separated by at least quality of the network.
avoid switching on when hot), do one metre. Failure to comply with the above
not connect dimmers to the same Three-phase networks: in case of requirements can compromise the
line of these lamps, keep the BUS three-phase networks, check the correct operation of the devices.

Maximum distance for the MAXIMUM DISTANCES FOR THE CONNECTION OF THE CONTACT INTERFACE
connection of the contact
interface MAX 50 m
The length of the connection
between the interface (basic or in
DIN module) and the traditional
A
PL1
PL2
M

type device must not exceed 50


SPE

m. Several pushbuttons may be


connected to the interface inputs. PL1 PL2 C

Bathroom
pull-cord
pushbutton

BUS

26
RULES ON THE VLAN NETWORK INFRASTRUCTURE

Below suggestions are made on how to organise the VLAN networks inside the
Ethernet network infrastructure in the hotel.
The services and devices in the hotel should be grouped into sub-networks
(VLAN), as suggested in the example below.

VLAN = Virtual Local Area Network

DSL INTERNET

ROUTER

OTHER AREAS

SWITCH SWITCH SWITCH


LAYER 3 LAYER 3 LAYER 3
AREA 1 AREA 2 AREA 3

Other VLAN Other VLAN

VLAN 1 VLAN 2 VLAN 3 VLAN 4 VLAN 1 VLAN 2 VLAN 3 VLAN 4

Devices of the ∙ IP telephones ∙ Wi-Fi data ∙ CCTV safety Devices of the ∙ IP telephones ∙ Wi-Fi data ∙ CCTV safety
hotel system (VOIP) network system hotel system ∙ PC network system
∙ MH201 ∙ PC ∙ Wire data ∙ MH 201 ∙ Printers ∙ Wire data
∙ F458 ∙ Printers network ∙ Various network
∙ Supervision ∙ Various services
software services ∙ PMS software
∙ PMS software

4 4
3 3
2 2
1 1

VLAN network legend

VLAN 1 = virtual network dedicated to the Bticino/Legrand hotel devices


VLAN 2 = virtual network dedicated to the IP telephony (VOIP) and various services (printers, etc...)
VLAN 3 = virtual network dedicated to the distribution of the WiFi and wired “Internet” signal
VLAN 4 = virtual network dedicated to safety (CCTV, etc...)

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 27


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

EXAMPLE OF A NETWORK INFRASTRUCTURE IN A HOTEL


WITH SUBDIVISION IN VLAN
2ND FLOOR

VLAN 2
VLAN 3

IP telephone
VLAN 1
RJ45
data
network

MH201
ROOM 4

DND MUR 4
Access point 2
3

for floor Wi-Fi


1
BUS/SCS VLAN 3
1ST FLOOR

VLAN 2
VLAN 3

IP telephone
VLAN 1

RJ45
data
network

MH201
ROOM 4

DND MUR 4
3
Access point 1
2

BUS/SCS for floor Wi-Fi VLAN 3


T FLOOR

VLAN 4
IP Server
INTERNET (over 100 zones)

DSL TVCC-IP camera


VLAN 1

VLAN 4
Router

(backbone 1)
TVCC-IP
camera
TECHNICAL

(backbone 2) Interface PMS


ROOM

(backbone 3) VLAN 2

28
OTHER FLOORS

2ND FLOOR
VLAN 2
VLAN 3
Switch layer 3
area 2
IP telephone
VLAN 1
RJ45
data
network

MH201

ROOM 3
TVCC-IP
camera
DND MUR

BUS/SCS

1ST FLOOR
VLAN 2
Switch layer 3 VLAN 3
area 1

IP telephone
VLAN 1
RJ45
data
network

MH201

ROOM 3
TVCC-IP DND MUR

camera
BUS/SCS

T FLOOR
VLAN 1

VLAN 2
Switch layer 3
area Ø

Supervision PC

4
RECEPTION

3
Printer
2
1

Access point
VLAN 3 for floor Wi-Fi
IP telephone

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 29


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

RULES ON THE ETHERNET NETWORK INFRASTRUCTURE


Three different diagrams, with different system types of ethernet network depending on the number of
rooms and areas to be controlled and the monitoring stations in reception, are supplied below.

1ST DIAGRAM
Type of system up to 100 zones (rooms or common areas) and a supervision PC in
Reception and PMS software
Hotel Rooms
ROOM 301 ROOM 310

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 201 ROOM 210

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 101 ROOM 110

MH201 MH201

Switch layer 3

MH201 MH201

Hotel management PMS


supervision software interface

Switch layer 3

Layer 3 switch or Router

Ethernet Network Dedicated BTicino/Legrand VLAN

NOTES FOR THE NETWORK ADMINISTRATORS:


Automatic device search procedures (based on UPnP), for both MH201 and Supervision Software, are associated with this
topology. These allow the association of each area gateway to its own ID.
In this case the network administrator must supply an automatic configuration service of the hosts in network on the Bticino/
Legrand VLAN (recommended solution), or explicitly choose to use the APIPA protocol, isolating the Legrand VLAN with the
other network sections.

30
2ND DIAGRAM
Type of system between 100 and 500 zones (rooms or common areas) and
a supervision PC in Reception and PMS software
Hotel Rooms
ROOM 400 ROOM 450

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 300 ROOM 350

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 100 ROOM 150

MH201 MH201

Switch layer 3

MH201 MH201

Hotel management PMS


supervision software interface

Switch layer 3

Layer 3 switch or Router

230 V

PR I

346020
PRI: 220 - 240V~
175-165mA
50/60Hz
1-2: 27Vdc
600mA

DC
1- 2 Power supply
346020
IP SERVER
F458 Dedicated BTicino/Legrand VLAN
Ethernet Network

NOTES FOR THE NETWORK ADMINISTRATORS:


As the number of rooms increases the functions of the UPnP protocol become inefficient.
Consequently the network administrator must make sure that there are no DHCP/DNS services on the Bticino/Legrand VLAN.
These services will be supplied by F458. The maximum number of rooms supported in this diagram is 500. 

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 31


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

RULES ON THE ETHERNET NETWORK INFRASTRUCTURE

3RD DIAGRAM
Type of system up to 500 areas (rooms or common areas) and 10 supervision PCs
and PMS software.
Hotel Rooms
ROOM 400 ROOM 450

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 300 ROOM 350

10° PC
Hotel
supervision
MH201 MH201

Switch layer 3 software

MH201 MH201

ROOM 100 ROOM 150


1° PC
Supervision Hotel
server supervision
software
MH201 MH201

Switch layer 3

MH201 MH201

PMS
interface

Switch layer 3

230 V Layer 3 switch or Router

PR I

346020
PRI: 220 - 240V~
175-165mA
50/60Hz
1-2: 27Vdc
600mA

DC
1- 2 Power supply
346020
IP SERVER
F458
Ethernet Network Dedicated BTicino/Legrand VLAN

NOTES FOR THE NETWORK ADMINISTRATORS:


As the number of rooms increases the functions of the UPnP protocol become inefficient.
Consequently the network administrator must make sure that there are no DHCP/DNS services on the Bticino/Legrand
VLAN. These services will be supplied by F458. The maximum number of rooms supported in this diagram is 500. 

32
TYPICAL WIRING DIAGRAM FOR HOTEL ROOM AND COMMON AREAS

The typical wiring diagrams to make systems in Hotels and B&B or in farm tourism are presented in
the following pages.

The diagrams presented are: Inside the room are the


following functions:
Basic wiring diagram – stand alone Courtesy light
Entrance door open control
Advanced wiring diagrams for centralised Refrigerator door open control
systems and with the supervision software Safe open control
Bathroom alarm
Entrance door bell
Section with the variants
Entrance door electric door lock controlo
Air conditioning system Eco function
Remote switch function

LEGEND
ITEM DESCRIPTION ITEM DESCRIPTION
E49 Power supply LN4648 Transponder key card switch
F91/12/24 Transformer LN4651 Key card reader outside the door and indicators
F411U1 DIN module 1 relay actuator LN4652 8-key scenario control
F411U2 DIN module 2 relay actuator LN4653 DND and MUR controls
F411/4 DIN module 4 relay actuator LN4691 Thermostat with display
F428 DIN module contact interface MH201 Scenario module IP
F430R8 Air conditioning actuator 3477 Basic contact interface
DIN module 4 relay actuator for temperature 3511 Magnetic sensors
F430/4
control
FT1A2N230 Room remote switch

NOTES
IMPORTANT NOTES
A The general switch GS (TM+EL) must be selected based on the absorption of the services installed.
B The TM switch must be selected based on the power supply used.
C E F The TM switch must be selected based on the loads connected.
D If the current supplied by the E49 is not sufficient to power the SCS system, it is possible to use the E46ADCN
power supply.
G The actuator to be used depends on the type of air conditioning system installed.
H In alternative, it is also possible to only use one actuator with 4 conduits (F411/4) instead of the two: F411U2 and
I F411U1.
Only use the most suitable sensor for the mechanical application. See the specific catalogue.
L
The devices to carry out the required functions must be configured using the MyHOME_Suite software.
M
The room identification number must be saved in the MH201 during the configuration.
N
It is possible to connect the system configuration PC at any point of the data network, and to use the PC at
reception to configure and maintain the system.

NOTE FOR DESIGNERS:


The devices listed in the legend are for the LivingLight series,
for all the other finishings, please refer to the catalogue section.

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 33


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

TYPICAL DIAGRAM OF A BASIC ROOM


- STAND ALONE SOLUTION

DIAGRAM 1
L
230 V
50 Hz N

Transformer
F91/12/24

TMG4 TMG2 TMG3 Room door


electric lock
IG Room remote
1 3 A1 switch

F B E
2 4 A2
FT1A2N230
230 Vac – 25 A Max
F420*
Scenario module
E49 F411U2
A = 1
PL1 = 1
E49
PRI: 220 – 240 V~
PL2 = 2
G = –
185 – 175 mA
50/60 Hz
SCS: 27 Vdc
600 mA
Light and socket power M = –
activated by the presence
inside the room
SCS

A = 9
PL = 9 D

SCS

L1
230 Vac
N2

A = 9 R1 = 0
Bell Transformer PL = 9 R2 = 1
12-24 Vac/dc M1 = 1 M = 0
max 1 A DEL1 = 0
M2 = 0
DEL2 = 1
LN4651 LN4648 LN4653
R1 = 0
R2 = 1
M = 0
L = 0
A = 1
PL = 1 DND MUR
T = 2

Scenarios set in the scenario module MH201:

PUTTING THE KEY CARD ON THE READER OUTSIDE THE ROOM


- Door lock activation for 2 sec (F411U2 C1)
3547
PUTTING THE KEY CARD IN THE SWITCH INSIDE THE ROOM * *Scenario programming, Item F420:
- Activation of the room light and socket remote switch (F411U2 C2) SCENARIO 1 ON 1-2
SCENARIO 9 OFF 1-2
TAKING THE KEY CARD OUT OF THE SWITCH INSIDE THE ROOM *
- Deactivation of the room light and socket remote switch after 60 sec (F411U2 C2)

34
TYPICAL DIAGRAM OF THE ETHERNET INFRASTRUCTURE IN A HOTEL

2ND FLOOR - CORRIDOR


To the other
floors

1ST FLOOR - CORRIDOR

Room 129 Room 128


To the 127 room

Switch layer 3

To the data sockets of room 127

Corridor Wi-Fi access point


Switch layer 3

To the
Technical
room, data N
network VDI
board (BTNET)

Existing hotel
Ethernet network
PC for the device
configuration.

RECEPTION

348402
PC + software
for room management

3547

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 35


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

TYPICAL ROOM DIAGRAM - CENTRALISED SOLUTION


WITH TRADITIONAL ELECTRIC SYSTEM
DIAGRAM 2

L
230 V
50 Hz N
To the floor switch

MH201 TMG4 TMG2 TMG1 NT4033 NT4005


Gateway NO Courtesy light
IG
pushbutton NO pushbutton
for bathroom
(TMG+ emergency
MH201
earth leak.) call
From HUB
Switch F B C
1st FLOOR

F428
E49 L
Wire data
D
C N1 N2

network F42 8

E49
PRI: 220 – 240 V~
185 – 175 mA
Virtual Configuration
Module 1 = contact 1 status
50/60 Hz
SCS: 27 Vdc
600 mA

N1 N2 light control,
SCS Module 2 = cyclic,
point-point,
1-3
Power for lights, sockets
and USB sockets always ON
BUS/SCS

L1
230 Vac
N2
Scenarios set in the scenario module MH201:

PUTTING THE KEY CARD ON THE READER OUTSIDE THE ROOM OPEN ROOM WINDOW Bell outside
- Door lock activation for 2 sec (F411/4 C1) - ECO temperature setting the door Transformer
- switching on the courtesy light for 120sec (F411/4 C3) - Thermostat key block 12-24 Vac/dc F91/12/24
max 1 A
OPEN/CLOSE THE ROOM ENTRANCE DOOR CLOSE ROOM WINDOW
- Activation of “Warning – Door” indication after 12 sec of opening - If room occupied: setting COMFORT temperature and
the door without (on SW). Event saved in the room event history thermostat key unlock
- Automatic reset when the door is closed again - If room not occupied: setting ECO temperature and LN4651
thermostat key lock R1 = 0
R2 = 1
PUTTING THE KEY CARD IN THE SWITCH INSIDE THE ROOM * M = 2
- Activation of the room light and socket remote switch (F411/4 C2) COURTESY LIGHT MANAGEMENT USING THE PUSHBUTTON INSIDE L = 0
- Setting Comfort temperature >only if window closed< THE ROOM (NT4005+F428) A = 1
PL = 1
- Unlock thermostat keys to adjust temperature and fan speed >only if - if there is a key card, step/step management of the courtesy light
T = 2
window closed< (F411/4 C3)
- if there is no key card the switching on is Timed for 120 sec
TAKING THE KEY CARD OUT OF THE SWITCH INSIDE THE ROOM * (F411/4 C3); if in the meantime the key card is put into the switch
- ECO temperature setting the light remains on steadily
- Deactivation of the room light and socket remote switch
after 30 sec (F411/4 C2) BATHROOM SOS ALARM
- switching off the courtesy light after 30sec (F411/4 C3) - Activation of “Alarm – SOS” (on SW) and backlighting flashing 3547
- Thermostat key block reader outside the room (LN/H4651 batch >14W41)
- Manual reset from SW. The local manual reset (CEN control) can
be set with different MH201 programming.

36
L
230 Vac
N
FAN-COIL
Courtesy 3 speeds
light 2 tubes

TMG3
Room remote
1 3 A1 switch Transformer
F91/12/24 M

Room door N L
electric lock
E 2 4 A2

FT1A2N230
230 Vac – 25 A Max

L1
F411/4 F430/4

L 1 2 3 4 5
G L
1 2 3 4 5
1 2 3 4 5
ART. F411/4
ART. F430/4

A = 1 ZA = 0
C1 C2 C3 C4 C1 C2 C3 C4
PL1 = 1 ZB1 = 1
Light and socket power PL2 = 2 ZB2 = 1
activated by the presence PL3 = 3 ZB3 = 1
inside the room PL4 = – ZB4 = 1
MOD = – N = 1

BUS/SCS

LN4691
ZA = 0
MODE
ZB1 = 1
A = 9 TYPE = 1
PL = 9 + HEAT = 3
M1 = CEN COOL = CEN

DEL1 = 0 R1 = 0 PUMP = 0
M2 = 0 R2 = 1 window COMFORT IN = 3
DEL2 = 0 M = 0 closed FAN

Virtual Configuration
LN4648 LN4653 3477 Module 1 = contact 2 status

Magnetic
A

window ECO/OFF*
PL1
PL2

window
M

open
SPE

sensor
* to be defined during
scenario configuration
PL1 PL2 C

DND MUR
on MH201

3510/3511 I
Entrance
door

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 37


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

TYPICAL ROOM DIAGRAM - CENTRALISED SOLUTION


WITH HOME AUTOMATION SYSTEM
DIAGRAM 4

L
230 V
50 Hz N

TMG2 TMG3 Courtesy


Entrance door
light
S1
IG
(TMG+
earth leak.)

E Transformer
B I
NT4033 F91/12/24
NO
pushbutton 1 3 A1 Room door
for bathroom electric lock
To the floor Switch emergency
call

2 4 A2
FT1A2N230
230 Vac
MH201 25 A Max
F428 F411/4
Gateway
E49 Virtual Configuration A = 1
From HUB C N1 N2 Module 1 = contact 1 status 1 2 3 4 5 PL1 = 1
Switch Module 2 = contact 2 status ART. F411/4 PL2 = 2
F42 8
PL3 = 3
1st FLOOR E49
MH201 PRI: 220 – 240 V~
185 – 175 mA
50/60 Hz
C1 C2 C3 C4 PL4 = –
SCS: 27 Vdc
MOD = –
600 mA

N1 N2
Light and socket power
SCS
activated by the presence
inside the room
D L L

L1

Wire data N1
BUS/SCS
network

TMG1

Scenarios set in the scenario module MH201:

PUTTING THE KEY CARD ON THE READER OUTSIDE THE ROOM OPEN ROOM WINDOW
- Door lock activation for 2 sec (F411/4 C1) - ECO temperature setting
- Switching on the courtesy light/s (F411/4 C3) - Thermostat key block C

OPEN/CLOSE THE ROOM ENTRANCE DOOR CLOSE ROOM WINDOW


- Activation of “Warning – Door” indication after 12 sec of opening - If room occupied: setting COMFORT temperature and thermostat key unlock
the door without (on SW). Event saved in the room event history - If room not occupied: setting ECO temperature and thermostat key lock
- Automatic reset when the door is closed again
COURTESY LIGHT MANAGEMENT USING THE PUSHBUTTON INSIDE THE ROOM
PUTTING THE KEY CARD IN THE SWITCH INSIDE THE ROOM * (NT4005+F428)
- Activation of the room light and socket remote switch (F411/4 C2) - if there is a key card, step/step management of the courtesy light (F411/4 C3)
- Setting Comfort temperature >only if window closed< - if there is no key card the switching on is Timed for 120 sec (F411/4 C3); if in
- Unlock thermostat keys to adjust temperature and fan speed >only if the meantime the key card is put into the switch the light remains on steadily
window closed<
BATHROOM SOS ALARM
TAKING THE KEY CARD OUT OF THE SWITCH INSIDE THE ROOM * - Activation of “Alarm – SOS” (on SW) and backlighting flashing reader outside
- ECO temperature setting the room (LN/H4651 batch >14W41)
- Switching off all the room lights after 20 sec of deactivation of the room - Manual reset from SW. The local manual reset (CEN control) can be set with
light and socket remote switch after 30 sec (F411/4 C2) different MH201 programming. Power for lights,
- Thermostat key block sockets and USB
sockets always ON

38
L

N
FAN-COIL
3 speeds
2 tubes - ROOM -
L1

N1

Bathroom Bathroom Room M


and room and room dimmer N L
lights lights
230 Vac
OUT 3
OUT 2
OUT 1
N
OUT 4
L1
F411/4 F411/4 F418 F430/4
A = 2 A = 2 L N
ZA = 0
1 2 3 4 5 PL1 = 1 1 2 3 4 5 PL1 = 5 1 2 3 4 5 ZB1 = 1
1 2 3 4 5
ART. F411/4 PL2 = 2 ART. F411/4 PL2 = 6 ZB2 = 1
ART. F430/4
PL3 = 3 PL3 = 7 A = 2 ZB3 = 1
C1 C2 C3 C4 PL4 = 4 C1 C2 C3 C4 PL4 = 8 PL = 9 C1 C2 C3 C4 ZB4 = 1
MOD = – MOD = – F418 G = N = 1

L L L G

BUS/SCS

L
LN4691
ZA = –
N MODE ZB = 1
TYPE = 1
Transformer window COMFORT +
HEAT = 3
closed COOL = CEN
F91/12/24 –

PUMP = 0
FAN IN = 3
Bell outside
the door window ECO/OFF*
12-24 Vac/dc open
max 1 A
R1 = 0 * to be defined during
R2 = 1 A = 9 scenario configuration
M = 2 PL = 9 on MH201
L = 0 M1 = CEN A = 9
A = 1 DEL1 = – R1 = 0 PL = 8
PL = 1 M2 = – R2 = 1 M = CEN
T = 2 DEL2 = – M = 0 LED = –

LN4651 LN4648 LN4653 LN4652 3510/3511 I

DND MUR

Magnetic window sensor

3547

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 39


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

VARIATIONS OF ROOM DIAGRAMS

Some diagrams which can be used to make and manage the emergency calls of the room
bathrooms or the common areas are supplied below.

VARIANT DIAGRAM 1 MANAGEMENT OF EMERGENCY CALL FROM THE BATHROOM WITH OPTIONAL RESET CONTROL

Notification with flashing of the outside-door reader (if configured)


The alarm is reset by the software or a local pushbutton by means of a scenario (if configured in the MH201
contact management).
A traditional pushbutton linked to the contact interface can be installed instead of the home automation
control.

Dedicated Legrand/BTicino
hotel VLAN network

3547
MH201
Bathroom call
reset control P2
LN4651 (optional) Virtual Configuration NO
Module 1 = contact 1 status pushbutton
3477 for bathroom
MH201
A emergency call
OFF
PL1
PL2
M
SPE

A1 = 9
PL1 = 7
MOD = CEN PL1 PL2 C

To other
BUS/SCS of the room or common areas
devices

40
VARIANT DIAGRAM 2 ROOM WITH INDEPENDENT TEMPERATURE CONTROL IN THE BATHROOM

For each zone (each MH201), common area or room, the system can manage a maximum of one LN/H4691
thermostat with “ECO function” with window contact connected directly to it.
In the same zone there are other thermostats with the management of the “ECO function”. Their contacts
must be managed using the 3477 contact interface, as in the following diagram.

Towel warmer
Low temperature
system

L
230 Va.c.
N

Devices that can be installed in the same 503 box

3477
Virtual Configuration A
PL1

Module 1 = contact n status PL2


M
SPE

PL1 PL2 C

window COMFORT
closed

Magnetic
window
sensor window ECO/OFF*
open
* to be defined during
scenario configuration
LN4691 on MH201
ZA = –
F430/2
MODE ZB = 2 3510/3511 I 1 2 3 4
TYPE = 1 1 2 3 4
+
HEAT = 1 ART. F430/2

– COOL = –
PUMP = – C1 C2 ZA = 0
FAN IN = – ZB1 = 2
N1 = 1
ZA = –
ZB2 = –
N2 = –

To other
BUS/SCS already present in the room
devices

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 41


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

VARIATIONS OF ROOM DIAGRAMS

VARIANT DIAGRAM 3 MANAGEMENT AND CONTROL OF COMMON ENTRANCES (MAX 8)

- Maximum number 8 manageable inputs cannot be discriminated.


- Can have progressive inputs every time the card touches the reader
(e.g. entries to the swimming pool or sauna).
- The transponder module item 353200 must have firmware 020015 or higher.

L
230 V
50 Hz
N

Courtesy Courtesy Courtesy


light light light

Transformer Transformer Transformer


F91/12/24 F91/12/24 F91/12/24

Room door Room door Room door


electric lock electric lock electric lock

F411U2 F411U2 F411U2


A = 1 A = 2 A = 3
PL1 = 1 PL1 = 1 PL1 = 1
PL2 = 2 PL2 = 2 PL2 = 2
G = – G = – G = –
M = PUL M = PUL M = PUL
C = – C = – C = –

BUS/SCS
already present in To other
the common area devices

R1 = 0
R2 = 1
M = 2 A = 0 A = 0
L = 4 B = 0 B = 0
A = 1 C = 2 C = 3
PL = 1 M = 2 M = 2
T = 1 T = – T = –

LN4651 353200 353200

Complete the Complete the


entrance panel with entrance panel with
SFERA accessories SFERA accessories

1° PASSAGE 2° PASSAGE 3° PASSAGE

3547 3547 3547

42
VARIANT DIAGRAM 3 MANAGEMENT AND CONTROL OF 3-SPEED AND 4-TUBE FAN-COIL

This variant proposes the diagram to manage a temperature control system with 4 tubes,
3-speed FAN-COIL and the use of a single 8-output actuator.

BUS/SCS BUS/SCS
already present To other
devices

L
230 Vac 230 Vac
N

LN4691
ZA = –
MODE ZB = 1
TYPE = 1
OUT 3
+
HEAT = 7
– COOL = CEN OUT 2
window CONFORT PUMP = –
OUT 1
closed FAN IN = 3
OUT 5
OUT 4
Magnetic
window N L
window ECO/OFF*
open sensor

* to be defined during L1 L2
scenario configuration F430R8
on MH201
3510/3511 G
I
OUT 3 ZA = –
ZB = 1
OUT 2 N = 1
OUT 1 LAOD = –

N
OUT 5
Magnetic window sensor OUT 4

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 43


WWW.BTICINO.COM
GENERAL RULES FOR INSTALLATION

PROCEDURE FOR STARTING A SYSTEM

The following procedure is an example of the starting of a system.


in the case of a system with fewer than 100 zones; rooms/common areas (without IP Server F458) the passages
shown in red must be omitted.
There are alternative methods (such as the creation of the project by scanning the system) which can be used as
needed.

1. Install the electric system in the rooms / common areas

2. Install the device IP Server F458

3. Install and run MyHOME_Suite (not necessarily on hotel reception PC)

4. Open MyHOME_Suite and create a new HOTEL project:

5. Select “IP Server F458” in the “project information” section

6. Enter in “structure”

7. Configure the F458 (see the corresponding manual)

a. After sending the F458 configuration wait for 1 minute and SWITCH THE HOTEL SYSTEM ON
AND OFF AGAIN (F458+MH201)
The system is up to speed with the assignment of the IP addresses in a few minutes.
In the mean time one can continue with the next steps.

8. Always in the “Structure” section, add buildings and floors by means of the “Edit” menu

9. Create a room/common area in the corresponding floor

10. For each room/common area created, customise Type, Name and Category (the MAC address field will be
configured in the next steps).
a. With F458 select DHCP

11. For each room/common area created, edit from the “Properties” window
a. Configure the MH201 (see the corresponding manual)

b. Add the necessary SCS devices and configure them appropriately

44
PROCEDURE FOR STARTING A SYSTEM

12. Return to the “Structure” section


13. The already created rooms/common areas can be “copied” and “pasted”.
In this case the following information must be customised


a. type, name and category


b. Unique code of the MH201


c. The ID of the SCS devices

d. Any other customisations of the individual room/common area (e.g. contacts, scenarios,
access control etc.)

14. In the “Structure” area enter the properties window, select “search on network” and search
for the IP devices

15. Drag the MH201 devices found in the network to the corresponding rooms/common areas based on
ID / MAC ADDRESS (be careful that the correspondence is correct)

16. At this point the configurations can be sent to the devices of each room/common area (by means of the
“edit room/area” function)


a. Send the configuration of the MH201

b. Connect to the MH20e entering the IP address in the template at the top left and sending
the configuration of the SCS devices

17. Save the MyHOME_Suite project file just completed by File → Save system
18. Create the project file of the supervision software from File → Create hotel file
19. Install and configure the Hotel Supervision software (see its manual) in which the file just created will be
loaded.

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 45


WWW.BTICINO.COM
Contents

46
Contents

46-71
Catalogue AXOLUTE + Dimensional data 48
LIVINGLIGHT + Dimensional data 60

72-127
Technical
sheets Technical sheets 74

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 47


WWW.BTICINO.COM
CATALOGUE

AXOLUTE
hotel A complete offer for a state of the
art electric system inside the whole

solutions
welcoming establishment and in
particular inside the hotel room.
All this to ensure that customers
feel immediately at ease. The offer
includes both standard traditional
functions, and more advanced
functions.

DESIGNED TO IMPROVE
THE COMFORT OF THE
CUSTOMER
A solution for all kinds of hotels

EQUIPMENT
INCLUDING SPECIFIC
PRODUCTS FOR
THE SCS-BUS ROOM

STANDARD EQUIPMENT

The BTicino offer for


the rooms, and in wider
terms for the whole
hotel establishment,
includes many more
devices that are
normally also used for
other applications.
UNIQUE AND ORIGINAL
Request or view the
Axolute catalogue

48
AXOLUTE
SCS-BUS devices (specific for the hotel)
This page lists the devices for hotel comfort and access control
solutions.

H4650 H4651 MH201 F458 F459

H4653 348402 3544SW


3546SW

Item KEY CARD SWITCHES Item IP SCENARIO MODULE


H4649 key card switch for function activation in the MH201 it manages scenarios related to hotel rooms - it
hotel room - slot light with built-in lamp - works as a gateway for the Configuration and
SCS-BUS connection - sizes: 2 modules - to be Supervisione software - it is necessary to install
completed with front cover in the desired look one module for each room or zone - SCS-BUS
H4648 key card switch for function activation in the hotel and ethernet network connection - sizes: 1 DIN
room with RFID technology recognition - slot light with module
built-in lamp - SCS-BUS connection - sizes: 2 modules -
SCENARIO MODULE
to be completed with front cover in the desired look
F420 device to save 16 scenarios for the Automation,
CONTROL INDICATORS FOR ROOM Sound system, Temperature control and Video
MANAGEMENT door entry applications
H4650 DO NOT DISTURB – MAKE UP THE ROOM indicator - 2 DIN modules
and bell pushbutton - SCS-BUS connection -
sizes: 2 modules IP SERVER
F458 IP SERVER to be used in systems with over 100
H4651 key card reader in RFID technology + DO NOT DISTURB
rooms or zones (over 100 MH201 installed). Size:
– MAKE UP THE ROOM indicator and bell pushbutton -
6 DIN modules
SCS-BUS connection - sizes: 2 modules
H4653 DO NOT DISTURB – MAKE UP THE ROOM control DRIVER MANAGER
to be completed with key covers - SCS-BUS F459 integration platform with other brand systems.
connection - sizes: 2 modules Size: 6 DIN modules

KEY CARDS AND KEY CARD PROGRAMMER Contact the BTicino System Integration Service to check the feasibility of specific
3547 Credit card key card (ISO 50x80 mm). It uses integrations and to request the licence needed to use the Driver manager (Toll
transponder technology Mifare classic ISO14443 free number 800.837035)
type A. To be used together with the key card
programmer, item code 348402. The key card SOFTWARE
can be customised and is sold in lots of 5 pieces. 3544SW Licence for the software for the room status
Compatible with reader H4651 starting from supervision, the basic management and the
production batch14W40. key card programming for a Hotel with up to 20
348402 Table-top key card programmer to be connected rooms
to the PC in the reception. 3546SW Licence for the software as above – for a Hotel
with more than 20 rooms

NOTE:​To request integration with PMS which use FIAS protocol (e.g. Fidelio) contact the BTicino Sale Service.

NOTE: White device Tech device Anthracite device Neutral item

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 49


WWW.BTICINO.COM
CATALOGUE

AXOLUTE
SCS-BUS devices (lights and automation)

H4651M2 H4652/2 H4652/3

HD4680 HS4680 H4652 HD4657M3 HS4657M3

Item CONTROLS Item GLASS DIGITAL CONTROLS


H4651M2 Special control – can drive an actuator MyHOME control which can control single loads
performing all the standard functions of a or group loads (e.g. lights and rolling shutters).
control and in addition some special functions: The configuration can take place in two different
activation of 4 scenarios saved in module ways: physical (putting the physical configurators
item F420, timings, activation of an actuator in their sockets) or virtual (the control can be
installed on a different bus than the control, configured remotely). It has capacitive keys,
selection of the fixed adjustment level and the which are touch activated. They can be identified
dimmer soft-start and soft-stop speed, sound by LED with light of adjustable intensity.
system, door lock switching on control, call to WHITE GLASS
the floor and switching on staircase light control HD4657M3 6-key control– size: 3 modules
and management of auxiliary channels. To be
completed with 1 or 2-module key covers with
one or two functions - 2 modules HD4657M4 8-key control– size: 4 modules
CONTROLS FOR SINGLE OR DOUBLE LOADS
H4652/2 control which can drive a single actuator for single WHICE
or double loads or two actuators for single loads
or independent double loads – to be completed HC4657M3 6-key control– size: 3 modules
with 1 2-module key cover for controls with one
or two functions or 2 1-module key covers with
one or two functions - 2 modules HC4657M4 8-key control– size: 4 modules
H4652/3 control which can drive three actuators for single
or double loads or two actuators for single loads
NIGHTER
or independent double loads – to be completed
with 3 1-module key covers for controls with one HS4657M3 6-key control– size: 3 modules
or two functions - 3 modules
CONTROL FOR ROLLING SHUTTER MANAGEMENT 8-key control– size: 4 modules
HS4657M4
H4660M2 2 module flush mounted control with reduced
thickness with 3 pushbuttons, only suitable for
operation with advanced actuators H4661M2
NOTE: the glass controls can be customised with symbols by means of silk screen
and F401, specific for the management of rolling
printing. On request as special orders.
shutters. In addition to monostable and bistable
UP/DOWN operation, the device also places the
rolling shutter in a stored (PRESET) position.
SCENARIO CONTROL Installation of the glass digital control Box Support Control
HD4680 customisable scenario control to control 4 503E H4703 HD4657M3
HC4680 independent "room situations" - 2 modules HC4657M3
HS4680 HS4657M3
Box 504E H4704 HD4657M4
H4652 8-KEY control for light management, rolling HC4657M4
shutter automation, sound system and scenarios HS4657M4
- SCS-BUS connection - sizes: 2 modules Support

3541 A5 sheets for the customisation of the symbols of item


3542 H4652
3541 = black;
3542 = white;
The sheets can be customised using the tool found in the
Control
MyHOME_Suite configuration software.
NOTE: White device Tech device Anthracite device Neutral item

50
AXOLUTE
SCS-BUS devices (lights and automation)

H4671M2 H4678 3475

Item ACTUATORS AND FLUSH MOUNTED ACTUATORS/ Item BASIC MODULE ACTUATOR
DIMMERS 3475 1 relay actuator - for single loads: 2 A resistive
H4671M2 actuator/control with 2 independent relays - for or incandescence lamps and 2 A cosϕ 0.5
single, double or mixed loads: 2 A resistive, 2 A for ferromagnetic transformers - suitable for
incandescence lamps, 500 W for reducer motors, 2 installation in ceiling lamps cups or in flush-
A cosϕ 0.5 for ferromagnetic transformers and 70 mounted boxes behind the control devices.
W for fluorescent lamps - logic relay interlock via 3476 1 relay actuator - for single loads: 2 A resistive
configuration. The device can be also configured or incandescence lamps, 2 A cosϕ 0.5 for
to manage a remote actuator - 2 modules ferromagnetic transformers - a traditional
H4671/1 1 relay actuator with control key - for single pushbutton with NO contact accepted in input
loads: 6 A resistive or incandescence lamps, 2
A cosϕ 0.5 for ferromagnetic transformers and ACTUATORS FOR ROLLING SHUTTER
MANAGEMENT
150 W fluorescent lamps - to be completed with
H4661M2 Flush-mounted 2-module actuator with 2
2-module key covers for single or double function
internal relays and 4 pushbuttons made to work
H4678 dimmer actuator for incandescence lamps and with the H4660M2 control devices to manage the
ferromagnetic transformers - 60 - 300 VA 230 rolling shutters. In addition to monostable and
Va.c. - to be completed with 2-module key covers bistable UP/DOWN operation, the actuator also
for single or double function - 2 modules places the rolling shutter in a stored (PRESET)
position.
F401 as above - with 3 pushbuttons - 2 DIN modules

LOADS THAT CAN BE DRIVEN (230 Va.c. 50/60 Hz)


Actuators Type

Energy saving LED lamps Linear fluorescent Compact fluorescent Electronic Ferromagnetic Reducer motors for
incandescence lamps 1) lamps transformers 3) transformers 2) 3) rolling shutters 4)
and halogen lamps
H4671M2 2A 70 W 0.3 A 70 W 0.3 A 2 A cosφ 0.5 2A
460 W Max 2 lamps 70 W Max 2 lamps 70 W 460 VA 460 W
H4671/1 6A 150 W 0.65 A 150 W 0.65 A 2 A cosφ 0.5 -
1380 W Max 3 lamps 150 W Max 3 lamps 150 W 460 VA -
H4678 0.25 - 1.30 A - - - - 0.25 - 1.30 A -
60 - 300 W - - - - 60 - 300 VA -
3475 2A 40 W - 40 W - 2 A cosφ 0.5 -
3476 460 W Max 1 lamp - Max 1 lamp - 460 VA -
H4661M2 - - - - - - 2 A 250 Va.c.
F401

Notes:
1) Power factor corrected fluorescent lamps, discharge lamps.
2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The symbol on the actuators refers to the rolling shutter reducer motors.

NOTE: White device Tech device Anthracite device Neutral item

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 51


WWW.BTICINO.COM
CATALOGUE

AXOLUTE
SCS-BUS devices (lights and automation)

F411U1 F411U2 F411/4 F411/1NC BMSW1002 BMSW1003


Item ACTUATORS FOR CENTRALISATIONS Item ACTUATORS FOR CENTRALISATIONS
F411U1 actuator with 1 two-way relay – for single loads: BMSW1002 ON/OFF actuator, 2 independent outputs
16 A resistive, 10 A incandescence lamps, 4 A with maximum load 16 A at 230 Va.c.,
cosϕ 0.5 for ferromagnetic transformers and 4 clamp connection and RJ45, IP20 protection
A for fluorescent lamps - it has ¨Zero crossing¨ index, power supply 100/240 Va.c. 50/60 Hz,
technology - 2 DIN modules pushbuttons for load direct control - zero-
F411U2 actuator with 2 independent relays – for crossing function - 4 DIN modules
single and double loads: 10 A resistive and 6 A BMSW1003 ON/OFF actuator, 4 independent outputs
incandescence lamps, 500 W for reducer motors, with maximum load 16 A at 230 Va.c.,
2 A cosϕ 0.5 for ferromagnetic transformers clamp connection and RJ45, IP20 protection
and 250 W for fluorescent lamps - logic relay index, power supply 100/240 Va.c. 50/60 Hz,
interlock via configuration - it has ¨Zero crossing¨ pushbuttons for load direct control - zero-
technology - 2 DIN modules crossing function - 6 DIN modules
F411/4 actuator with 4 independent relays - for BMDI1002 1/10V dimmer, “Zero Crossing” technology, 4
single, double or mixed loads: 2 A resistive, 2 A outputs with maximum load 4.3 A at 230 V a.c.,
incandescence lamps, 500 W for reducer motors, clamp connection, IP20 protection index, 10 DIN
2 A cosϕ 0.5 for ferromagnetic transformers and modules, power supply100/240 V a.c. 50/60 Hz,
70 W for fluorescent lamps - logic relay interlock pushbuttons for load direct control
via configuration - 2 DIN modules BMSW1005 ON/OFF actuator, “Zero Crossing” technology, 8
F411/1NC actuator with 1 two-way NC relay for single loads independent outputs with maximum load 16 A
16 A resistive, 10 A for incandescence lamps and at 230 V a.c., clamp connection, IP20 protection
4 A for fluorescent lamps. On switching on the index, 10 DIN modules, power supply100/240 V
device always has the contact closed (ON status) a.c. 50/60 Hz, pushbuttons for load direct control
and the contact is opened with an OFF command.
In this way there would be no voltage from the
BUS, the device would remain in the ON state,
keeping the load on – 2 DIN modules
LOADS THAT CAN BE DRIVEN (250 Va.c. 50/60 Hz)
Actuators Type

Energy saving incandescence LED lamps Linear Compact fluorescent Electronic Ferromagnetic Reducer motors for
and halogen lamps fluorescent lamps 1) lamps transformers 3) transformers 2) 3) rolling shutters 4)
F411U1 10 A 500 W 4A 500 W 4A 4 A cosφ 0.5 -
2300 W Max 10 lamps 920 W Max 10 lamps 920 W 920 VA -
F411U2 10 A 250 W 4A 250 W 4A 4 A cosφ 0.5 2A
1380 W Max 4 lamps 230 W Max 4 lamps 230 W 460 VA 460 W
F411/4 2A 70 W 0.3 A 70 W 0.3 A 2 A cosφ 0.5 2A
460 W Max 2 lamps 70 W Max 2 lamps 70 W 460 VA 460 W
F411/1NC 10 A 500 W 4A 500 W 4A 4 A cosφ 0.5 -
2300 W Max 10 lamps 920 W Max 10 lamps 920 W 920 VA -
BMSW1002 16 A 2.1 A 10 X (2 X 36 W) 1150 W 16 A 16 A -
3680 W 500 VA 4.3 A 5A 3680 W 3680 W -
BMSW1003 16 A 2.1 A 10 X (2 X 36 W) 1150 W 16 A 16 A -
3680 W 500 VA 4.3 A 5A 3680 W 3680 W -
BMDI1002 Dimmer for ballast - 4 x 4.3 A outputs
4x 1000VA@ 230 Vac
4x500VA@ 230 Vac
BMSW1005 16 A 2.1 A 4.3 A 5A 16 A 16 A -
3680 W 500 VA 10X2X36 W 1150 VA 3680 W 3680 W -
Notes:
1) Power factor corrected fluorescent lamps, discharge lamps.
2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The symbol on the actuators refers to the rolling shutter reducer motors.

52 NOTE: White device Tech device Anthracite device Neutral item


AXOLUTE
SCS-BUS devices (lights and automation)

F413N BMDI1001 F414 F416U1 F418U2 F429


Item DIMMERS FOR CENTRALISATIONS Item MULTI-LOAD DIMMERS FOR CENTRALISATIONS
BMDI1001 1/10V dimmer, 1 output with maximum load 4.3 F416U1 Multi-load dimmer, 1 output with maximum
A at 230 Va.c., clamp connection and RJ45, IP20 load 4.3 A at 230 Va.c., clamp connection and
protection index, 6 DIN modules, power supply RJ45, IP20 protection index, power supply
100/240 Va.c. 50/60 Hz, pushbutton for load 100/240 Va.c. 50/60 Hz, pushbutton for
direct control - 6 modules load direct control - 6 DIN modules
F413N 1-output dimmer to supply fluorescent F418 dimmer for the management of dimmer LEDs,
lamps or LED sources with input 1-10 V for compact fluorescent lamps (CFL), energy saving
single loads up to 2.5 A at 230 Va.c. – type of halogen lamps and electronic transformers at
screw connection - power supply 27 Vd.c. – 110-230 V. Power supply 27 Vd.c., absorption
absorption 30 mA – maximum 10 mA - version for fastening on DIN rail - 4
10 ballast that can be connected modules
(clamps 1-2) - with pushbutton for load direct F418U2 two-channel dimmer for the management of
control - version for fastening on DIN rail - 2 dimmer LEDs, compact fluorescent lamps (CFL),
modules energy saving halogen lamps and electronic
F414 1-output dimmer to supply incandescence and transformers at 110-230V. Possibility of
halogen lamps with ferromagnetic transformer parallelisation of the two channels to increase
– power supply 27 Vd.c. – absorption 9 mA - the maximum power which can be managed.
with pushbutton for load direct control - version power supply 27 Vd.c., absorption 18 mA -
for fastening on DIN rail - 4 modules version for fastening on DIN rail - 4 modules
F429 DALI dimmer with 8 independent outputs for
the connection of up to 16 DALI reactors for each
output – 230 V a.c. power supply 50/60 Hz; 110
- 240 Vd.c. – absorption 5 mA - with pushbutton
for load direct control - version for fastening on
DIN rail - 6 modules

LOADS THAT CAN BE DRIVEN (230 VA.C. 50/60 HZ)


Actuators Type

Energy saving incandescence LED lamps Linear fluorescent Compact fluorescent Electronic Ferromagnetic Reducer motors for
and halogen lamps lamps 1) lamps transformers 3) transformers 2) 3) rolling shutters 4)
BMDI1001 4.3 A - 4.3 A 4.3 A - - -
1000 VA - 1000 VA 1000 VA - - -
F413N - - 2 A 460 W 5) - - - -
- - Max 10 ballast, type T5, - - - -
T8, compact or driver
for LED
F414 0.25 - 4.3 A - - - - 0.25 - 4.3 A -
60 - 1000 VA - - - - 60 - 1000 VA -
F416U1 4.3 A - - - 4.3 A 4.3 A -
40 - 1000 W - - - 40 - 1000 W 40 - 1000 W -
F418 1-300 W 1-300 VA - 1-300 VA 1-300 VA - -
F418U2 2x300 VA 2x300 VA - 2x300 VA 2x300 VA 2x300 VA -
F429 SCS/DALI dimmer interface - 8 x16 ballast

Notes:
1) Power factor corrected fluorescent lamps, discharge lamps.
2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The symbol on the actuators refers to the rolling shutter reducer motors. 5) Only compatible with lamps with 1/10 V ballast.
NOTE: White device Tech device Anthracite device Neutral item

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 53


WWW.BTICINO.COM
CATALOGUE

AXOLUTE
SCS-BUS devices (temperature control)

H4691 F430R8 F430R3V10 F430V10

Item THERMOSTAT Item DIN ACTUATORS


H4691 flush mounted thermostat with backlit display. F430R8 actuator with 8 independent relays for the control
It can be used to control the temperature of an of on-off valves, motorised valves (open-close
individual zone, irrespective of a temperature and three points), pumps and fan coils with 2 and
control central unit being installed as part of the 4 tubes - 4A resistive, 1A motor valves, pumps
system or not. It features a temperature probe and fan-coils- SCS-bus connection - sizes: 4 DIN
and an input for the connection of a contact modules
line (e.g. window contact). It can be used for F430R3V10 actuator with 3 independent relays and 2 x 0-10
the management of different types of systems, Volts outputs for the control of fan coils with 2 and
and the adjustment of the fan speed when fan 4 tubes with proportional 0-10 Volt valves - 4A
coils are used. Possibility of automatic operation resistive, 1A fan coil - SCS-BUS connection - sizes:
(summer/winter), with compatible systems. SCS- 4 DIN modules
BUS connection - Sizes: 2 modules. F430V10 actuator with 2 x 0-10 Volt outputs for the control
of 0-10 proportional valves - SCS-BUS connection
- sizes: 2 DIN modules
F430/2 2 independent relay actuator for the control of
on-off valves, (open-close) motor valves and
pumps - 6A resistive, 2A motor valves and pumps
- SCS-BUS connection - 2 DIN modules
F430/4 4 independent relay actuator - for the control of
on-off valves, (open-close) motor valves, pumps
and 2-tube fan coil - 4A resistive, 1A motor valves,
pumps and fan-coil - SCS-BUS connection - 2 DIN
modules

NOTE: White device Tech device Anthracite device Neutral item


54
AXOLUTE
SCS-BUS devices (interface and accessories)

E46ADCN 3515

3510M 3511 3512

Item POWER SUPPLIES Item VARIOUS ACCESSORIES


E46ADCN power supply - input 230 Va.c. output 27 3515 spare removable clamp
Vd.c. SELV – maximum consumption 300 mA
– maximum output current: 1.2 A - DIN rail
mounted model - space requirement 8 DIN MAGNETIC CONTACTS
modules – for flush mounted or wall mounted 3510 NC electromagnetic contact interface detectors
switchboards and protection line - flush mounted version
E49 compact power supply - input 230 Va.c. 3510M NC electromagnetic contact interface detectors
- output 27 Vd.c. - maximum current provided and protection line – made of brass with high
600 mA - Sizes: 2 DIN modules mechanical resistance, for installation in non
ferromagnetic material windows and doors, or in
CONTACT INTERFACE low section doors and windows
3477 basic module control interface with 2 3510PB NC electromagnetic contact interface detectors
independent contacts for the control of 2 and protection line – made of brass, with high
actuators for single function loads, or 1 actuator mechanical resistance for installation in all types
for double function loads (shutters) – the inputs of doors and windows and reinforced doors.
accepts two traditional switches or pushbuttons 3511 NC electromagnetic contact interface detectors
with NO and NC contact, or a traditional two-way and protection line - visible mounted version
switch, or interlocked pushbuttons 3512 NC electromagnetic contact interface detectors
F428 Basic module control interface with 2 and protection line – made of die cast aluminium,
independent contacts for the control of 2 for installation on tilting or sliding doors. Preset
actuators for single function loads, or 1 actuator for floor installation.
for double function loads (shutters) – the inputs 3513 NC electromagnetic contact interface detectors
accepts two traditional switches or pushbuttons and protection line - version for visible
with NO and NC contact, or a traditional twoway installation on metal surfaces
switch, or interlocked pushbuttons - 2 DIN
modules

NOTE: White device Tech device Anthracite device Neutral item


GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 55
WWW.BTICINO.COM
CATALOGUE

AXOLUTE
SCS-BUS devices (accessories)

3501/0 3501/1 3501/2 3501/3 3501/4

3501/CEN 3501/GR 3501/AMB 3501/AUX

3501/PUL 3501/SLA 3501/CEN 3501/T 3501K/1 336904 L4669


L4669HF L4669/500
CONFIGURATORS – SINGLE-TYPE PACKAGE OF
Item 10 PIECES Item CONFIGURATOR KIT
3501/0 configurator 0 3501K Configurator kit from No. 0 to No. 9
3501/1 configurator 1
3501/2 configurator 2
3501/3 configurator 3 3501K/1 Kit of configurators AUX, GEN, GR, AMB,ON, OFF,
O/I, PUL, SLA, CEN, , M




3501/4 configurator 4
3501/5 configurator 5
3501/6 configurator 6 CONNECTION CABLES
configurator 7 L4669 sheathed pair made up of 2 flexible wires with
3501/7
unshielded plaited sheath - insulation 300/500 V
3501/8 configurator 8 - complies with standards CEI 46-5 and CEI 20-20
3501/9 configurator 9 - coil length 100 metres
3501/CEN configurator GEN L4669/500 As above, coil length 500 metres
3501/GR configurator GR
3501/AMB configurator AMB
L4669KM1 as above - reel lenght 1000 metres
3501/AUX configurator AUX
3501/ON configurator ON
3501/OFF configurator OFF 336904 specific cable with 2 twisted conductors. It can be
3501/OI configurator OI installed in underground piping, in accordance
with CEI 20-13 and CEI 20-14 standards. - coil
CONFIGURATORS – SINGLE-TYPE PACKAGE OF length 200 metres
10 PIECES
L4669HF as above - low toxicity cable without halogens -
3501/PUL configurator PUL
ideal for application in environments where fire
3501/SLA configurator SLA hazard safety is critical - coil length 200 metres
3501/CEN configurator CEN
3501/T configurator
➝ ➝

3501/TM configurator M

automation

FOR MORE INFORMATION ON THE DESIGN AND


INSTALLATION OF THE SCS-BUS SOLUTIONS SEE THE
SPECIFIC MyHOME TECHNICAL GUIDE
www.catalogo-sfogliabile.bticino.it/myhomegb/ DESIGN AND
INSTALLATION
GUIDE

NOTE: White device Tech device Anthracite device Neutral item

56
AXOLUTE
Traditional devices Finishing accessories for SCS-BUS and
traditional devices

HD4177 HD4285C2 HC4033 HS4547 HC4915DD HC4915MR

H4372V230H H4549

Item KEY CARD SWITCH Item FRONT COVERS FOR KEY CARD SWITCHES
H4549 key card switch for the power supply inside the HD4547 front cover for traditional or SCS key card switch
hotel room - slot light with built-in lamp - 30 HC4547 - 2 modules
second switch-off delay - power supply 230 Va.c. HS4547
- 2 modules - to be completed with front cover in KEY COVERS WITH SYMBOLS FOR SCS CONTROL
the desired look HD4915DD “Do not disturb” key covers
H4548 key card switch for the power supply inside the HC4915DD
hotel room with RFID technology recognition - HS4915DD
slot light with built-in lamp - 30 second switch off “Do not disturb” key covers - 2 modules
HD4915M2DD
delay - power supply 230 Va.c. - 2 modules - to be HC4915M2DD
completed with front cover in the desired look HS4915M2DD
HD4915MR “Make up the room” key covers
HC4915MR
LAMPHOLDER FOR OFF-DOOR NOTIFICATION HS4915MR
H4372V230H off-door lampholder with double optical “Room light” key covers
HD4915BL
notification: do not disturb and make up room – HC4915BL
use 2 LEDs item LN4742V12T (12V) HS4915BL
SHAVER SOCKETS HD4915M2BL “Room light” key covers - 2 modules
HD4177 shaver socket with insulation transformer HC4915M2BL
HC4177 - input voltage 230 Va.c. 50/60 hz HS4915M2BL
HS4177 - output voltage 115/230 Va.c. 20 VA
KEY COVER WITH SYMBOLS FOR
PULL-CORD PUSHBUTTON AXIAL CONTROLS
HD4033 cord pushbutton 1 P NO 10 A for bathroom alarm HD4921BL “Bed light” key covers
HC4033 HC4921BL
HS4033 HS4921BL
USB CHARGERS HD4921M2BL “Bed light” key covers - 2 modules
HD4285C 5 Vdc USB socket for charging electronic devices HC4921M2BL
HC4285C up to 750 mA like mobile phones, smartphones, HS4921M2BL
HS4285C tablets and similar – 230 Vac power supply HD4921DD “Do not disturb” key covers
HD4285C2 5 Vdc USB socket for quick charge of one single HC4921DD
HC4285C2 electronic device (mobile phones, smartphones, HS4921DD
HS4285C2 tablets or similar) up to 1.550 mA or simultaneous HD4921MR “Make up the room” key covers
charging of two devices up to 750 mA – 230 Vac HC4921MR
power supply HS4921MR

RJ45, audio and video sockets


and the other devices, consult
the Axolute catalogue

NOTE: White device Tech device Anthracite device Neutral item


GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 57
WWW.BTICINO.COM
CATALOGUE

AXOLUTE
Room insulation remote switch

The contactors must be used in the system to switch off some loads or devices in the room when the guest is not
present (key card not in the switch).

FT1A2N24 FT2A3N230 FT1A2N24S

Item AC3 CONTACTORS Item AC7A CONTACTORS


In = 25A No. of
Vn (Vac) In (A) Contact
No. of modules
Vn (Vac) In (A) Contact 24 2 NO 1
modules FT1A2N24M
FT1AC1N24 1NO+1NC 1 FT1A1N230M 1NO 1
FT1A2N24 24 2 NO 1 FT1A2N230M 230 25 2 NO 1
FT2A4N24 4 NO 2 FT2A4N230M 4 NO 2
FT1AC1N230 1NO+1NC 1 In = 40-63A
FT1A2N230 2 NO 1 FC2A4/24N 2 NO 2
FT2A3N230 3 NO 2 FC4A4/24N 24 40 4 NO 3
FT2A4N230 25 4 NO 2 FC4A6/24N 63 4 NO 3
230
FT2AC2N230 2NO+2NC 2 FC2A4/230N 2 NO 2
FT1C2N230 2NC 1 FC3A4/230N 40 3 NO 3
FT2C4N230 4 NC 2 FC4A4/230N 230 4 NO 3
FC4A6/230N 63 4 NO 3

SILENT
FT1A1N24S 1NO 1
FT1A2N24S 24 2 NO 1
FT1A1N230S 25 1NO 1
FT1A2N230S 230 2 NO 2

TECHNICAL FEATURES

Reference standards: CEI EN 61095


Rated pulse voltage Uimp (kV): 4
Rated reel voltage Vn (Vac): 24 or 230
Rated insulating voltage Ui (Vac): 500
Rated current In (A) at 30°C: 25-40-63
Conditioned short-circuit current (kA): 3
Rated frequency (Hz): 50/60
Operating temperature (°C): -25 to 40
Max No. of mechanical manoeuvres 1000000
Power consumption for each pole (W): 1.5
Protection index (terminal area/other areas): IP20/IP40
Maximum section of connectable flexible/rigid cable (mm2): see table

58
122 4,5

122 122 144 3,5

AXOLUTE
Dimensional data

131,5
86

86

86
AXOLUTE AIR COVER PLATES 122 122 122 4,5 4,5 4,5 122 4,5

122 122 122 122 122 122


122 144 122 144
144 3,5 3,5 3,5 190,7
144 3,5 4,5

104 127 150

131,5
131,5

131,5

131,5
86
86

86

86
86

86

86

86

86

86

86

86

86

95
95
95
HW4802... HW4803... HW4804... HW4806... HW4826...
190,7 190,7 190,7 4,5 4,5 4,5 190,7 4,5

AXOLUTE RECTANGULAR COVER PLATES


127127 195
127

86
104
104104
86

86

86

127
127127 150150
150
Aluminium Glass-stone Wood

surface-mounted

surface-mounted

surface-mounted
95
95
95
95
95
95
95
95

95
95

141,5
141,5
141,5
HA4802... HA4803... - HC4657M3 HA4804... - HC4657M4 HA4806... 8,3 9,5 8,3
HA4829... - HS4657M3 - HS4657M4 HA4830...

0 127 195
195195
Aluminium Glass-stone Wood
95
95
95
95

141,5

surface-mounted

surface-mounted

surface-mounted

HA4826... 8,3 9,5 8,3

AXOLUTE ELLIPTICAL COVER PLATES

103103 103 126126 126 149149 149 126126 126

TABLE WITH DIN SIZES (mm)


103 126 149 126 No. of A B C
93
93
93
93
93
93
93
93
93

modules
138 ,5
138 ,5
138 ,5

1 17.5 82 66
HB4802... HB4803... HB4804... 2 35 82 66
93
93
93

195195 195 HB4829... 3 52.5 82 66


138 ,5

103 126 149 126 4 70 82 66


Zamak 5 87.5 82 66
195 6 105 82 66
plastic
93
93
93

Zamak wood 7 122.5 82 66


93
93
93

plastic
138 ,5

surface-mounted

8 140 82 66
surface-mounted

wood
9 157.5 82 66
93

10 175 82 66
195
12 210 82 66
HB4806... 9,2 HB4826... 9,29,2 9,2
HB4830...
93

MODULAR DEVICES BASIC INTERFACE MODULE


22,5 45 67,5 40 18
40
45

45

45

3475 - 3476 - 3477


1 module 2 modules 3 modules

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 59


WWW.BTICINO.COM
CATALOGUE

LIVINGLIGHT
hotel A complete offer for a state of the

solutions
art electric system inside the whole
welcoming establishment and in
particular inside the hotel room.
All this to ensure that customers feel
immediately at ease. The offer includes
both standard traditional functions, and
more advanced functions.

DESIGNED TO IMPROVE
THE COMFORT OF THE
CUSTOMER
A solution for all kinds of hotels

EQUIPMENT
INCLUDING SPECIFIC
PRODUCTS FOR THE
SCS-BUS ROOM

STANDARD EQUIPMENT

The BTicino offer for


the rooms, and in wider
terms for the whole
hotel establishment,
includes many more
devices that are
normally also used for
other applications.

Request or view the


Livinglight catalogue

60
LIVINGLIGHT
SCS-BUS devices (specific for the hotel)
This page lists the devices for hotel comfort and access control
solutions.

LN4650 LN4651 MH201 F458 F459

LN4653 348402 3544SW


3546SW

Item KEY CARD SWITCHES Item IP SCENARIO MODULE


LN4649 key card switch for function activation in the MH201 it manages scenarios related to hotel rooms - it
hotel room - slot light with built-in lamp - works as a gateway for the Configuration and
SCS-BUS connection - sizes: 2 modules - to be Supervisione software - it is necessary to install
completed with front cover in the desired look one module for each room or zone - SCS-BUS
LN4648 key card switch for function activation and ethernet network connection - sizes: 1 DIN
in the hotel room with RFID technology module
recognition - slot light with built-in lamp
SCENARIO MODULE
- SCS-BUS connection - sizes: 2 modules -
to be completed with front cover in the desired look F420 device to save 16 scenarios for the Automation,
Sound system, Temperature control and Video
CONTROL INDICATORS FOR ROOM door entry applications
MANAGEMENT - 2 DIN modules
LN4650 DO NOT DISTURB – MAKE UP THE ROOM indicator
IP SERVER
and bell pushbutton - SCS-BUS connection -
F458 IP SERVER to be used in systems with over 100
sizes: 2 modules
rooms or zones (over 100 MH201 installed). Size:
LN4651 key card reader in RFID technology + DO NOT DISTURB 6 DIN modules
– MAKE UP THE ROOM indicator and bell pushbutton -
SCS-BUS connection - sizes: 2 modules DRIVER MANAGER
LN4653 DO NOT DISTURB – MAKE UP THE ROOM control F459 integration platform with other brand systems.
to be completed with key covers - SCS-BUS Size: 6 DIN modules
connection - sizes: 2 modules
Contact the BTicino System Integration Service to check the feasibility of specific
KEY CARDS AND KEY CARD PROGRAMMER integrations and to request the licence needed to use the Driver manager (Toll
3547 Credit card key card (ISO 50x80 mm). It uses free number 800.837035)
transponder technology Mifare classic ISO14443
type A. To be used together with the key card SOFTWARE
programmer, item code 348402. The key card 3544SW Licence for the software for the room status
can be customised and is sold in lots of 5 pieces. supervision, the basic management and the
Compatible with reader H4651 starting from key card programming for a Hotel with up to 20
production batch14W40. rooms
348402 Table-top key card programmer to be connected 3546SW Licence for the software as above – for a Hotel
to the PC in the reception. with more than 20 rooms

NOTE:​To request integration with PMS which use FIAS protocol (e.g. Fidelio) contact the BTicino Sale Service.

NOTE: White device Tech device Anthracite device Neutral item

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 61


WWW.BTICINO.COM
CATALOGUE

LIVINGLIGHT
SCS-BUS devices (lights and automation)

LN4651M2 LN4652/2 LN4652/3 N4680 L4680 LN4652

Item CONTROLS Item CONTROL FOR ROLLING SHUTTER MANAGEMENT


L4651M2 Special control – can drive an actuator LN4660M2 2 module flush mounted control with reduced
performing all the standard functions of a thickness with 3 pushbuttons, only suitable for
control and in addition some special functions: operation with advanced actuators LN4661M2
activation of 4 scenarios saved in module and F401, specific for the management of rolling
item F420, timings, activation of an actuator shutters. In addition to monostable and bistable
installed on a different bus than the control, UP/DOWN operation, the device also places the
selection of the fixed adjustment level and the rolling shutter in a stored (PRESET) position.
dimmer soft-start and soft-stop speed, sound
system, door lock switching on control, call to SCENARIO CONTROL
the floor and switching on staircase light control L4680 customisable scenario control to control 4
and management of auxiliary channels. To be N4680 independent "room situations" - 2 modules
NT4680
completed with 1 or 2-module key covers with
one or two functions - 2 modules LN4652 8-KEY control for light management, rolling
shutter automation, sound system and scenarios
CONTROLS FOR SINGLE OR DOUBLE LOADS - SCS-BUS connection - sizes: 2 modules
L4652/2 control which can drive a single actuator for single 3541 A5 sheets for the customisation of the symbols of item
or double loads or two actuators for single loads 3542 H4652
or independent double loads – to be completed 3541 = black;
with 1 2-module key cover for controls with one 3542 = white;
or two functions or 2 1-module key covers with The sheets can be customised using the tool found in the
one or two functions - 2 modules MyHOME_Suite configuration software.
L4652/3 control which can drive three actuators for single
or double loads or two actuators for single loads
or independent double loads – to be completed
with 3 1-module key covers for controls with one
or two functions - 3 modules

NOTE: White device Tech device Anthracite device Neutral item

62
LIVINGLIGHT
SCS-BUS devices (lights and automation)

LN4671M2 L4678 3475

Item ACTUATORS AND FLUSH MOUNTED ACTUATORS/ Item BASIC MODULE ACTUATOR
DIMMERS 3475 1 relay actuator - for single loads: 2 A resistive
LN4671M2 actuator/control with 2 independent relays or incandescence lamps and 2 A cosϕ 0.5
- for single, double or mixed loads: 2 A resistive, 2 A for ferromagnetic transformers - suitable for
incandescence lamps, 500 W for reducer motors, 2 installation in ceiling lamps cups or in flush-
A cosϕ 0.5 for ferromagnetic transformers and 70 mounted boxes behind the control devices.
W for fluorescent lamps - logic relay interlock via 3476 1 relay actuator - for single loads: 2 A resistive
configuration. The device can be also configured or incandescence lamps, 2 A cosϕ 0.5 for
to manage a remote actuator - 2 modules ferromagnetic transformers - a traditional
L4671/1 1 relay actuator with control key pushbutton with NO contact accepted in input
- for single loads: 6 A resistive or incandescence
lamps, 2 A cosϕ 0.5 for ferromagnetic ACTUATORS FOR ROLLING SHUTTER
MANAGEMENT
transformers and 150 W fluorescent lamps - to be
LN4661M2 Flush-mounted 2-module actuator with 2
completed with 2-module key covers for single or
internal relays and 4 pushbuttons made to work
double function
with the LN4660M2 control devices to manage
L4678 dimmer actuator for incandescence lamps and the rolling shutters. In addition to monostable
ferromagnetic transformers - 60 - 300 VA 230 and bistable UP/DOWN operation, the actuator
Va.c. - to be completed with 2-module key covers also places the rolling shutter in a stored
for single or double function - 2 modules (PRESET) position.
F401 as above - with 3 pushbuttons - 2 DIN modules

LOADS THAT CAN BE DRIVEN (230 VA.C. 50/60 HZ)


Actuators Type

Energy saving LED lamps Linear fluorescent Compact fluorescent Electronic Ferromagnetic Reducer motors for
incandescence and lamps 1) lamps transformers 3) transformers 3) 2) rolling shutters 4)
halogen lamps

LN4671M2 2A 70 W 0.3 A 70 W 0.3 A 2 A cosφ 0.5 2A


460 W Max 2 lamps 70 W Max 2 lamps 70 W 460 VA 460 W
L4671/1 6A 150 W 0.65 A 150 W 0.65 A 2 A cosφ 0.5 -
1380 W Max 3 lamps 150 W Max 3 lamps 150 W 460 VA -
L4678 0.25 - 1.30 A - - - - 0.25 - 1.30 A -
60 - 300 W - - - - 60 - 300 VA -
3475 2A 40 W - 40 W - 2 A cosφ 0.5 -
3476 460 W Max 1 lamp - Max 1 lamp - 460 VA -
LN4661M2 - - - - - - 2 A 250 Va.c.
F401

Notes:
1) Power factor corrected fluorescent lamps, discharge lamps.
2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The symbol on the actuators refers to the rolling shutter reducer motors.

NOTE: White device Tech device Anthracite device Neutral item

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 63


WWW.BTICINO.COM
CATALOGUE

LIVINGLIGHT
SCS-BUS devices (lights and automation)

F411U1 F411U2 F411/4 F411/1NC BMSW1002 BMSW1003


Item ACTUATORS FOR CENTRALISATIONS Item ACTUATORS FOR CENTRALISATIONS
F411U1 actuator with 1 two-way relay – for single loads: BMSW1002 ON/OFF actuator, 2 independent outputs
16 A resistive, 10 A incandescence lamps, 4 A with maximum load 16 A at 230 Va.c.,
cosϕ 0.5 for ferromagnetic transformers and 4 clamp connection and RJ45, IP20 protection
A for fluorescent lamps - it has ¨Zero crossing¨ index, power supply 100/240 Va.c. 50/60 Hz,
technology - 2 DIN modules pushbuttons for load direct control - zero-
F411U2 actuator with 2 independent relays – for crossing function - 4 DIN modules
single and double loads: 10 A resistive and 6 A BMSW1003 ON/OFF actuator, 4 independent outputs
incandescence lamps, 500 W for reducer motors, with maximum load 16 A at 230 Va.c.,
2 A cosϕ 0.5 for ferromagnetic transformers clamp connection and RJ45, IP20 protection
and 250 W for fluorescent lamps - logic relay index, power supply 100/240 Va.c. 50/60 Hz,
interlock via configuration - it has ¨Zero crossing¨ pushbuttons for load direct control - zero-
technology - 2 DIN modules crossing function - 6 DIN modules
F411/4 actuator with 4 independent relays - for BMDI1002 1/10V dimmer, “Zero Crossing” technology, 4
single, double or mixed loads: 2 A resistive, 2 A outputs with maximum load 4.3 A at 230 V a.c.,
incandescence lamps, 500 W for reducer motors, clamp connection, IP20 protection index, 10 DIN
2 A cosϕ 0.5 for ferromagnetic transformers and modules, power supply100/240 V a.c. 50/60 Hz,
70 W for fluorescent lamps - logic relay interlock pushbuttons for load direct control
via configuration - 2 DIN modules BMSW1005 ON/OFF actuator, “Zero Crossing” technology, 8
F411/1NC actuator with 1 two-way NC relay for single loads independent outputs with maximum load 16 A
16 A resistive, 10 A for incandescence lamps and at 230 V a.c., clamp connection, IP20 protection
4 A for fluorescent lamps. On switching on the index, 10 DIN modules, power supply100/240 V
device always has the contact closed (ON status) a.c. 50/60 Hz, pushbuttons for load direct control
and the contact is opened with an OFF command.
In this way there would be no voltage from the
BUS, the device would remain in the ON state,
keeping the load on – 2 DIN modules
LOADS THAT CAN BE DRIVEN (250 Va.c. 50/60 Hz)
Actuators Type

Energy saving incandescence LED lamps Linear fluorescent Compact fluorescent Electronic transformers Ferromagnetic Reducer motors for
and halogen lamps lamps 1) lamps 3)
transformers 2) 3) rolling shutters 4)
F411U1 10 A 500 W 4A 500 W 4A 4 A cosφ 0.5 -
2300 W Max 10 lamps 920 W Max 10 lamps 920 W 920 VA -
F411U2 10 A 250 W 4A 250 W 4A 4 A cosφ 0.5 2A
1380 W Max 4 lamps 230 W Max 4 lamps 230 W 460 VA 460 W
F411/4 2A 70 W 0.3 A 70 W 0.3 A 2 A cosφ 0.5 2A
460 W Max 2 lamps 70 W Max 2 lamps 70 W 460 VA 460 W
F411/1NC 10 A 500 W 4A 500 W 4A 4 A cosφ 0.5 -
2300 W Max 10 lamps 920 W Max 10 lamps 920 W 920 VA -
BMSW1002 16 A 2.1 A 10 X (2 X 36 W) 1150 W 16 A 16 A -
3680 W 500 VA 4.3 A 5A 3680 W 3680 W -
BMSW1003 16 A 2.1 A 10 X (2 X 36 W) 1150 W 16 A 16 A -
3680 W 500 VA 4.3 A 5A 3680 W 3680 W -
BMDI1002 Dimmer for ballast - 4 x 4.3 A outputs
4x 1000VA@ 230 Vac
4x500VA@ 230 Vac
BMSW1005 16 A 2.1 A 4.3 A 5A 16 A 16 A -
3680 W 500 VA 10X2X36 W 1150 VA 3680 W 3680 W -
Notes:
1) Power factor corrected fluorescent lamps, discharge lamps.
2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The symbol on the actuators refers to the rolling shutter reducer motors.

64 NOTE: White device Tech device Anthracite device Neutral item


LIVINGLIGHT
SCS-BUS devices (lights and automation)

F413N BMDI1001 F414 F416U1


Item DIMMERS FOR CENTRALISATIONS Item MULTI-LOAD DIMMERS FOR CENTRALISATIONS
BMDI1001 1/10V dimmer, 1 output with maximum load 4.3 F416U1 Multi-load dimmer, 1 output with maximum
A at 230 Va.c., clamp connection and RJ45, IP20 load 4.3 A at 230 Va.c., clamp connection and
protection index, 6 DIN modules, power supply RJ45, IP20 protection index, power supply
100/240 Va.c. 50/60 Hz, pushbutton for load 100/240 Va.c. 50/60 Hz, pushbutton for
direct control - 6 modules load direct control - 6 DIN modules
F413N 1-output dimmer to supply fluorescent F418 dimmer for the management of dimmer LEDs,
lamps or LED sources with input 1-10 V for compact fluorescent lamps (CFL), energy saving
single loads up to 2.5 A at 230 Va.c. – type of halogen lamps and electronic transformers at
screw connection - power supply 27 Vd.c. – 110-230 V. Power supply 27 Vd.c., absorption
absorption 30 mA – maximum 10 mA - version for fastening on DIN rail - 4
10 ballast that can be connected modules
(clamps 1-2) - with pushbutton for load direct F418U2 two-channel dimmer for the management of
control - version for fastening on DIN rail - 2 dimmer LEDs, compact fluorescent lamps (CFL),
modules energy saving halogen lamps and electronic
F414 1-output dimmer to supply incandescence and transformers at 110-230V. Possibility of
halogen lamps with ferromagnetic transformer parallelisation of the two channels to increase
– power supply 27 Vd.c. – absorption 9 mA - the maximum power which can be managed.
with pushbutton for load direct control - version power supply 27 Vd.c., absorption 18 mA -
for fastening on DIN rail - 4 modules version for fastening on DIN rail - 4 modules
F429 DALI dimmer with 8 independent outputs for
the connection of up to 16 DALI reactors for each
output – 230 V a.c. power supply 50/60 Hz; 110
- 240 Vd.c. – absorption 5 mA - with pushbutton
for load direct control - version for fastening on
DIN rail - 6 modules

LOADS THAT CAN BE DRIVEN (230 VA.C. 50/60 HZ)


Actuators Type

Energy saving incandescence LED lamps Linear fluorescent Compact fluorescent Electronic transformers Ferromagnetic Reducer motors for
and halogen lamps lamps 1) lamps 3)
transformers 2) 3) rolling shutters 4)
BMDI1001 4.3 A - 4.3 A 4.3 A - - -
1000 VA - 1000 VA 1000 VA - - -
F413N - - 2 A 460 W 5) - - - -
- - Max 10 ballast, type T5, - - - -
T8, compact or driver
for LED
F414 0.25 - 4.3 A - - - - 0.25 - 4.3 A -
60 - 1000 VA - - - - 60 - 1000 VA -
F416U1 4.3 A - - - 4.3 A 4.3 A -
40 - 1000 W - - - 40 - 1000 W 40 - 1000 W -
F418 1-300 W 1-300 VA - 1-300 VA 1-300 VA - -
F418U2 2x300 VA 2x300 VA - 2x300 VA 2x300 VA 2x300 VA -
F429 SCS/DALI dimmer interface - 8 x16 ballast

Notes:
1) Power factor corrected fluorescent lamps, discharge lamps.
2) Account must be taken of the transformer yield to calculate the effective power of the load connected to the actuator. For example if a dimmer is connected to a 100 VA ferromagnetic
transformer with yield 0.8, the effective power of the load will be 125 VA.
3) The transformer must be loaded at its rated power and however never less than 90% of this power. It is preferable to use a single transformer rather than several transformers in
parallel. For example it is better to use a single 250 VA transformer with 5 50W spotlights connected rather than use 5 50 VA transformers in parallel each with a 50 W spotlight.
4) The symbol on the actuators refers to the rolling shutter reducer motors. 5) Only compatible with lamps with 1/10 V ballast.
NOTE: White device Tech device Anthracite device Neutral item

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 65


WWW.BTICINO.COM
CATALOGUE

LIVINGLIGHT
SCS-BUS devices (temperature control)

LN4691 F430R8 F430R3V10 F430V10

Item THERMOSTAT Item DIN ACTUATORS


LN4691 flush mounted thermostat with backlit display. F430R8 actuator with 8 independent relays for the control
It can be used to control the temperature of an of on-off valves, motorised valves (open-close
individual zone, irrespective of a temperature and three points), pumps and fan coils with 2 and
control central unit being installed as part of the 4 tubes - 4A resistive, 1A motor valves, pumps
system or not. It features a temperature probe and fan-coils- SCS-bus connection - sizes: 4 DIN
and an input for the connection of a contact modules
line (e.g. window contact). It can be used for F430R3V10 actuator with 3 independent relays and 2 x 0-10
the management of different types of systems, Volts outputs for the control of fan coils with 2 and
and the adjustment of the fan speed when fan 4 tubes with proportional 0-10 Volt valves - 4A
coils are used. Possibility of automatic operation resistive, 1A fan coil - SCS-BUS connection - sizes:
(summer/winter), with compatible systems. SCS- 4 DIN modules
BUS connection - Sizes: 2 modules. F430V10 actuator with 2 x 0-10 Volt outputs for the control
of 0-10 proportional valves - SCS-BUS connection
- sizes: 2 DIN modules
F430/2 2 independent relay actuator for the control of
on-off valves, (open-close) motor valves and
pumps - 6A resistive, 2A motor valves and pumps
- SCS-BUS connection - 2 DIN modules
F430/4 4 independent relay actuator - for the control of
on-off valves, (open-close) motor valves, pumps
and 2-tube fan coil - 4A resistive, 1A motor valves,
pumps and fan-coil - SCS-BUS connection - 2 DIN
modules

NOTE: White device Tech device Anthracite device Neutral item


66
LIVINGLIGHT
SCS-BUS devices (interface and accessories)

E46ADCN 3515

3510M 3511 3512

Item POWER SUPPLIES Item VARIOUS ACCESSORIES


E46ADCN power supply - input 230 Va.c. output 27 3515 spare removable clamp
Vd.c. SELV – maximum consumption 300 mA
– maximum output current: 1.2 A - DIN rail
mounted model - space requirement 8 DIN MAGNETIC CONTACTS
modules – for flush mounted or wall mounted 3510 NC electromagnetic contact interface detectors
switchboards and protection line - flush mounted version
E49 compact power supply - input 230 Va.c. 3510M NC electromagnetic contact interface detectors
- output 27 Vd.c. - maximum current provided and protection line – made of brass with high
600 mA - Sizes: 2 DIN modules mechanical resistance, for installation in non
ferromagnetic material windows and doors, or in
CONTACT INTERFACE low section doors and windows
3477 basic module control interface with 2 3510PB NC electromagnetic contact interface detectors
independent contacts for the control of 2 and protection line – made of brass, with high
actuators for single function loads, or 1 actuator mechanical resistance for installation in all types
for double function loads (shutters) – the inputs of doors and windows and reinforced doors.
accepts two traditional switches or pushbuttons 3511 NC electromagnetic contact interface detectors
with NO and NC contact, or a traditional two-way and protection line - visible mounted version
switch, or interlocked pushbuttons 3512 NC electromagnetic contact interface detectors
F428 basic module control interface with 2 independent and protection line – made of die cast aluminium,
contacts for the control of 2 actuators for single for installation on tilting or sliding doors. Preset
function loads, or 1 actuator for double function for floor installation.
loads (shutters) – the inputs accepts two 3513 NC electromagnetic contact interface detectors
traditional switches or pushbuttons with NO and and protection line - version for visible
NC contact, or a traditional twoway switch, or installation on metal surfaces
interlocked pushbuttons - 2 DIN modules

NOTE: White device Tech device Anthracite device Neutral item


GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 67
WWW.BTICINO.COM
CATALOGUE

LIVINGLIGHT
SCS-BUS devices (accessories)

3501/0 3501/1 3501/2 3501/3 3501/4

3501/CEN 3501/GR 3501/AMB 3501/AUX

3501/PUL 3501/SLA 3501/CEN 3501/T 3501K/1 336904 L4669


L4669HF L4669/500
CONFIGURATORS – SINGLE-TYPE PACKAGE OF
Item 10 PIECES Item CONFIGURATOR KIT
3501/0 configurator 0 3501K Configurator kit from No. 0 to No. 9
3501/1 configurator 1
3501/2 configurator 2
3501/3 configurator 3 3501K/1 Kit of configurators AUX, GEN, GR, AMB,ON, OFF,
O/I, PUL, SLA, CEN, , M




3501/4 configurator 4
3501/5 configurator 5
3501/6 configurator 6 CONNECTION CABLES
configurator 7 L4669 sheathed pair made up of 2 flexible wires with
3501/7
unshielded plaited sheath - insulation 300/500
3501/8 configurator 8 V - complies with standards CEI 46-5 and CEI 20-
3501/9 configurator 9 20 - coil length 100 metres
3501/CEN configurator GEN L4669/500 As above, coil length 500 metres
3501/GR configurator GR
3501/AMB configurator AMB
L4669KM1 as above - reel lenght 1000 metres
3501/AUX configurator AUX
3501/ON configurator ON
3501/OFF configurator OFF 336904 specific cable with 2 twisted conductors. It can be
3501/OI configurator OI installed in underground piping, in accordance
with CEI 20-13 and CEI 20-14 standards. - coil
CONFIGURATORS – SINGLE-TYPE PACKAGE OF length 200 metres
10 PIECES
L4669HF as above - low toxicity cable without halogens -
3501/PUL configurator PUL
ideal for application in environments where fire
3501/SLA configurator SLA hazard safety is critical - coil length 200 metres
3501/CEN configurator CEN
3501/T configurator
➝ ➝

3501/TM configurator M

automation

FOR MORE INFORMATION ON THE DESIGN AND


INSTALLATION OF THE SCS-BUS SOLUTIONS SEE THE
SPECIFIC MyHOME TECHNICAL GUIDE
www.catalogo-sfogliabile.bticino.it/myhomegb/

DESIGN AND
INSTALLATION
GUIDE

NOTE: White device Tech device Anthracite device Neutral item


68
LIVINGLIGHT
Traditional devices Finishing accessories for SCS and
traditional devices

LN4549 L4177 NT4547 NT4915DD NT4915MR

N4033 N4373H NT4915TN N4915SETBL

Item KEY CARD SWITCH Item FRONT COVERS FOR KEY CARD SWITCHES
LN4549 key card switch for the power supply inside the N4547 front cover for traditional or SCS key card switch
hotel room - slot light with built-in lamp - 30 NT4547 - 2 modules
second switch-off delay - power supply 230 Va.c. L4547
- 2 modules - to be completed with front cover in N4551 front cover for traditional or SCS key card switch
the desired look NT4551 - 3 modules
LN4548 key card switch for the power supply inside the L4551
hotel room with RFID technology recognition - KEY COVERS WITH SYMBOLS FOR SCS CONTROL
slot light with built-in lamp - 30 second switch off N4915DD key cover for rocker control devices with ”do not
delay - power supply 230 Va.c. - 2 modules - to be NT4915DD disturb” symbol
completed with front cover in the desired look L4915DD
N4915MR key cover for rocker control devices with ”make
NT4915MR up room” symbol
LAMPHOLDER FOR OFF-DOOR NOTIFICATION L4915MR
N4373H off-door lampholder with double optical N4915M2DD “DO NOT DISTURB” key covers - 2 modules
NT4373H notification: do not disturb and make up room – NT4915M2DD
L4373H use 2 LEDs item LN4742V12T (12V) L4915M2DD
SHAVER SOCKETS KEY COVERS THAT CAN BE CUSTOMISED AND KIT
N4177* shaver socket with insulation transformer OF DIFFUSERS
NT4177 * - input voltage 230 Va.c. 50/60 hz N4915TN key cover for rocker control devices
L4177* - output voltage 115/230 Va.c. 20 VA NT4915TN that can be customised with lightable diffuser
* NOTE: In case of installation using AIR cover plates, the box extension must be L4915TN
used to make wiring easier N4915SETBL kit of 50 lightable diffusers with bed light symbol
PULL-CORD PUSHBUTTON NT4915SETBL
cord pushbutton 1 P NO 10 A for bathroom alarm L4915SETBL
N4033
NT4033
L4033

RJ45, audio and video sockets


and the other devices, consult
the Livinglight catalogue

NOTE: White device Tech device Anthracite device Neutral item


GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 69
WWW.BTICINO.COM
CATALOGUE

LIVINGLIGHT
Room insulation remote switch
The contactors must be used in the system to switch off some loads or devices in the room when the guest is not
present (key card not in the switch).

FT1A2N24 FT2A3N230 FT1A2N24S

Item AC3 CONTACTORS Item AC7A CONTACTORS


In = 25A No. of
Vn (Vac) In (A) Contact
No. of modules
Vn (Vac) In (A) Contact FT1A2N24M 24 2 NO 1
modules
FT1AC1N24 1NO+1NC 1 FT1A1N230M 1NO 1
FT1A2N24 24 2 NO 1 FT1A2N230M 230 25 2 NO 1
FT2A4N24 4 NO 2 FT2A4N230M 4 NO 2
FT1AC1N230 1NO+1NC 1 In = 40-63A
FT1A2N230 2 NO 1 FC2A4/24N 2 NO 2
FT2A3N230 3 NO 2 FC4A4/24N 24 40 4 NO 3
FT2A4N230 25 4 NO 2 FC4A6/24N 63 4 NO 3
230
FT2AC2N230 2NO+2NC 2 FC2A4/230N 2 NO 2
FT1C2N230 2NC 1 FC3A4/230N 40 3 NO 3
FT2C4N230 4 NC 2 FC4A4/230N 230 4 NO 3
FC4A6/230N 63 4 NO 3

SILENT
FT1A1N24S 1NO 1
FT1A2N24S 24 2 NO 1
FT1A1N230S 25 1NO 1
FT1A2N230S 230 2 NO 2

TECHNICAL FEATURES

Reference standards: CEI EN 61095


Rated pulse voltage Uimp (kV): 4
Rated reel voltage Vn (Vac): 24 or 230
Rated insulating voltage Ui (Vac): 500
Rated current In (A) at 30°C: 25-40-63
Conditioned short-circuit current (kA): 3
Rated frequency (Hz): 50/60
Operating temperature (°C): -25 to 40
Max No. of mechanical manoeuvres 1000000
Power consumption for each pole (W): 1.5
Protection index (terminal area/other areas): IP20/IP40
Maximum section of connectable flexible/rigid cable (mm2): see table

70
LIVINGLIGHT
Dimensional data
SQUARE COVER PLATES MODULAR DEVICES
88 10,2 120 9,2 142 9,2
22,5 45 67,5
86

86

86

45

45
LNA4802... LNA4803... LNA4804...
LND4802KR LNA4819... LND4804KR 1 module 2 modules
LND4803KR 120 9,3
LND4819KR
22,5 45 67,5
208 9,2

134

45

45

45
86

LNA4807... LNA4826... 3 modules


LND4807KR LND4826KR

ROUND COVER PLATES DIN DEVICES


102,9 128 128 10 10 150 10 10
102,9 10,310,3 150 A C
89
89

89

89
89

89

LNB4802... LNB4803... LNB4804...

130 10,3
2 DIN modules
130 10,3

216 10

10 TABLE WITH DIN SIZES (mm)


216
No. of A B C
137

modules
137
89

1 17.5 82 66
89

2 35 82 66
LNB4807... LNB4826... 3 52.5 82 66
4 70 82 66
LIVINGLIGHT
88 88
AIR COVER
4,754,75 PLATES 120120 4,754,75 142142 4,754,75 5 87.5 82 66
88 88 88 4,754,754,75 120 120120 4,754,754,75 142 142142 4,754,754,75 6 105 82 66
7 122.5 82 66
86 86
86 86
86 86

8 140 82 66
86 86
86 86

86 86

93 119 93 140 119 140


86
86

86

9 157.5 82 66
10 175 82 66
LNC4802... LNC4803... LNC4804... 12 210 82 66
80

80
80

80

80

4,754,75
120120 BASIC INTERFACE MODULE
120 120120 4,754,754,75
40 18
208208 4,754,75

208 208208 4,754,754,75


134 134
134 134

40
86 86

134
86 86
86

3475 - 3476 - 3477


LNC4807... LNC4826... 118

LIVING INTERNATIONAL COVER PLATES


93 93 93 119 119 119 206 140 140 140 206
127 127
128
80

80
80

80

80

80

80

80

80
80

80

80

L4802.. L4803.. L4804.. L4807.. L4826..

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 71


WWW.BTICINO.COM
72
Contents
72-127
Technical Sheets Technical and dimensional data, standards, mounting and installation 74

The technical sheets in this booklet are only part of the range of
SCS-BUS devices in the catalogue pages.
Only the technical sheets of the basic hotel offer are present.

FOR MORE INFORMATION ON THE DESIGN AND


INSTALLATION OF THE SCS-BUS SOLUTIONS SEE THE
SPECIFIC MyHOME TECHNICAL GUIDE
www.catalogo-sfogliabile.bticino.it/myhomegb/

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 73


WWW.BTICINO.COM
TECHNICAL SHEETS

BUS/SCS E49
compact power supply

Description 1
The power supply can be used to supply power to systems with SCS BUS. On the output,
the unit supplies a 27 Vdc continuous low voltage, with a maximum current of 600
mA. It is protected by an integrated fuse (not replaceable) against short circuit and
overload.
It’s a double insulation safety device in accordance with CEI EN60065, and can therefore
be used in conjunction with a SELV source in accordance with paragraph 4.11.1.2.5 of
CEI 64-8-4. The power supply unit is fitted inside a 2 DIN rail module enclosure, and its
installation must be in accordance with the regulations of the country of use. PRI
In general, the following requirements must be met:
- The power supply must be always installed in appropriate sockets
- It must not be exposed to water drops or splashes. E49
- Do not block the ventilation openings. PRI: 220 – 240 V~
185 – 175 mA
- A two-pole circuit breaker must be installed, with contact separation of at least 3 mm 50/60 Hz
located nearby the power supply. The circuit breaker is used to disconnect the power SCS: 27 Vdc
600 mA
supply from the mains, and to protect it.
2
The device must not be configured.
SCS

Technical data
PRI (AC power supply input)
Rated voltage: 220 – 240 V
Rated current: 175 – 185 mA
Working voltage range: 187 – 265 V
Operating frequency range: 47 – 63 Hz 3
Power consumption - full load: 21.5 W max
Power consumption: 5.3 W max
Full load yield: 80% typ. Legend
Stand by power: lower than 1 W
1. Clamps (PRI) for connection to the supply voltage
Operating temperature: (+5) – (+40) °C
Integrated fuse (PRI side): F1 T2A 250V (NOT REPLACEABLE) 2. LED: – green (power supply ON)
– red (output current overload)
SCS
3. (SCS) clamps for connection to the BUS/SCS
Rated voltage: 27 V +/- 100 mV
Rated current: 0 – 0.6 A
Rated power: 16.2 W

Dimensional data
2 DIN modules

MM00260-a-EN 01/07/2013

74
BUS/SCS E46ADCN
power supply

Description
The power supply can be used to supply power to systems with SCS BUS. The output
provides 27 Vdc continuous low voltage, with maximum current of 1.2 A. It is
electronically protected (without fuse) against overload and short circuit.
It’s a double insulation safety device in accordance with CEI EN60065, and can therefore
be used in conjunction with a SELV source in accordance with paragraph 4.11.1.2.5 of
CEI 64-8-4.
The power supply unit is fitted inside a 8 DIN rail module enclosure, and its installation
230 ±10% V 50-60Hz
must be in accordance with the regulations of the country of use. IMAX =300 mA

In general, the following requirements must be met:


- The power supply must be always installed in appropriate sockets
– It must not be exposed to water drops or splashes.
- Do not block the ventilation openings.
- A two-pole circuit breaker must be installed, with contact separation of at least 3 mm
located nearby the power supply.
The circuit breaker is used to disconnect the power supply from the mains, and to
protect it. 3 2 1

Technical data Legend


Supply voltage: 230 Vac ± 10% @ 50/60 Hz 1. Clamps (1-2) with 27 Vdc output voltage
Max. input absorption: 300 mA 2. Clamps (BUS) for connection to the SCS BUS
Output voltage: 27 Vdc
3. Clamps for connection to the supply voltage
Maximum current provided: 1.2 A
Maximum power consumption: 11 W
Reference standards: EN60065
Protection index: IP30
Operating temperature: (+5) – (+40) °C

Dimensional data
Size: 8 DIN modules

MM00273-b-EN 01/07/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 75


WWW.PROFESSIONISTI.BTICINO.IT
TECHNICAL SHEETS

Additional power supply 230 V 346020

Description
1
2 DIN module devices which allows to:
- locally supply the single video door entry handsets and entrance panels.
- supply some accessories of the Communication and MY HOME catalogues (ex: Web server,
A/V server, scenario programmers, 2WIRE/IP interface, switch 10/100, ADSL modem router,
Hub-TV and SCS modulator).
It is a double insulation safety device.
The power supply unit is fitted inside a 2 DIN rail module plastic enclosure, and its PR I
installation must be in accordance with the regulations of the country of use.
The device must not be configured.
346020
PRI: 220 - 240V~
175-165mA
Technical data 50/60Hz
1-2: 27Vdc
PRI (AC power supply input): 600mA
Rated voltage: 220 – 240 Vac 2
Rated current: 180 – 190 mA
Working voltage range: 187 – 265 V
Operating frequency range: 47 – 63 Hz 1- 2
Power consumption - full load: 20 W max
Power consumption: 3.8 W (max.)
Full load yield: 80% typ.
Stand by power: <1W
Operating temperature: (+5) – (+40) °C
Integrated fuse (PRI side): F1 T2A 250V (NOT REPLACEABLE) 3
1 - 2 (DC output):
Rated voltage: 27 V +/- 100 mV Legend
Rated current: 0 – 0.6 A
Rated power: 16.2 W 1. Input connection clamps 230 Vac
2. Operation status notification LED:
(GREEN ON) – normal operation of the power supply
Standards, certifications, marks (RED ON) – output current overload
Reference standards: CEI EN60065 3. Output 1 – 2 connection clamps

Dimensional data

2 DIN modules

Mounting, installation

Respect the following rules:

- The power supply must be always installed in appropriate sockets;


– It must not be exposed to water drops or splashes;
- Do not block the ventilation openings;
- A two-pole circuit breaker must be installed, with contact separation of at least 3 mm
located nearby the power supply. The circuit breaker is used to disconnect the power
supply from the mains, and to protect it.

BT00659-b-EN 20/09/2013

76
BUS-SCS 0 675 65 H4649
key card switches 5 727 35 LN4649
5 722 35

Description Front view


Key card switch for the power supply inside the hotel room. Thanks to the LED backlit
slot, the device can be found in the dark. An automatic switch off delay can also be set.
It can be used with key cards with sizes between 45 mm and 54 mm (ISO).
The device can be configured in two different ways: 1
- Physical configuration, by inserting the configurators in the appropriate sockets.
-Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration 2
has the advantage of offering many more options when compared with the physical
configuration.
3

Technical data
Power supply from SCS BUS: 18-27 Vdc
Max. absorption: 6 mA Rear view
Absorption in stand by: 5 mA
Operating temperature: (+5) – (+40) °C

Standards, certifications, marks


5
EN 60669-2-1
EN 50491-5-1
EN 50428

Dimensional data
2 flush mounted modules

Legend
1. Programming key: Learn IN
2. Programming key: Learn OUT
3. LED
4. Key card detection microswitch
5. Configurator socket
6. Connector for BUS connection

MM00496-b-EN 02/10/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 77


WWW.PROFESSIONISTI.BTICINO.IT
TECHNICAL SHEETS

BUS-SCS 0 675 65 H4649


key card switches 5 727 35 LN4649
5 722 35

Physical configuration Ethernet connection with the system.

There are two modes: Ethernet


network
- CENTRALIZED (to be used with MH201), to recall scenarios managed by the scenario
programmer. When the key card is inserted and removed, the device forwards
a signal to the scenario programmer, which depending on the scenarios set will MH201
activate the corresponding functions programmed. Switch HUB

A = 1-9 (CEN control address)


PL = 1-9 (CEN control address)
M1 = CEN
MH201

DEL1 = no configurator
M2 = no configurator
DEL2 = no configurator Ethernet
network
Note: the insertion of the key card corresponds to “Pushbutton 1” of the control, while
the removal of the key card corresponds to “Pushbutton 2” of the control. BUS-SCS

- SCENARIO, where by inserting the key card a group of actuators is enabled, and an
entrance scenario is activated (through the scenario module), and by removing the
key card an exit scenario is activated (through the scenario module), thanks to which
all the group actuators will switch off and then disable after a set time delay.
A = 1-9 (as scenario module) PC for the configuration
PL = 1-9 (as scenario module)
M1 = 1-8 (activation of the corresponding scenario: see table B)
DEL1 = 0 - 9 (switching on time delay at the insertion of the key card: see table A) SCENARIO mode programming
M2 = no configurator SCENARIO mode programming
DEL2 = 0 - 9 (switching off time delay after the removal of the key card: see table A) This operation is performed to create a link between the key card switch and the
scenario module. The procedure is as follows:
Table A 1) Power the key card switch. Check that the scenario module is in programming
Configurator value Time mode, with the green LED on;
0 0 2) Press and hold down programming key 1 (Learn IN) or 2 (Learn OUT) until the LED
1 1 min starts flashing (approximately 3 seconds);
2 2 min 3) Create the scenario using the system controls and actuators;
4) Once the scenario has been saved, briefly press programming key 1 (Learn IN) or 2
3 3 min (Learn 2) to exit the programming status;
4 4 min 5) The scenario module will also have to exit programming status (see the scenario
5 5 min module technical information).
6 10 min
7 15 min Cancelling the programming in SCENARIO mode:
1) Power the key card switch. Check that the scenario module is in programming
8 15 sec mode,
9 30 sec with the green LED on;
2) Press and hold down programming key 1 (Learn IN) or 2 (Learn OUT) for 8 seconds.
After 3 seconds the LED will turn on, after a further 5 seconds it will turn off again;
Table B 3) Release the key;
4) The LED flashing, followed by the LED switching off, indicates that the programming
Configurator value Scenario - Group has been cancelled;
1 Scenario-group (Sce1=1, Sce2=9, Gr=1) 5) The scenario module will also have to exit programming status (see the scenario
2 Scenario-group (Sce1=2, Sce2=10, Gr=2) module technical information).
3 Scenario-group (Sce1=3, Sce2=11, Gr=3)
4 Scenario-group (Sce1=4, Sce2=12, Gr=4)
5 Scenario-group (Sce1=5, Sce2=13, Gr=5) 1
6 Scenario-group (Sce1=6, Sce2=14, Gr=6)
7 Scenario-group (Sce1=7, Sce2=15, Gr=7)
8 Scenario-group (Sce1=8, Sce2=16, Gr=8) 2

Note: Sce 1 = scenario activated on insertion 3


Sce 2 = scenario activated on removal
Gr = actuator group 4

Configuration with MyHOME_Suite software


This is performed using the appropriate application MyHOME_Suite, this mode has 1. Programming key: Learn IN
the advantage of offering many more options when compared with the physical 2. Programming key: Learn OUT
configuration. The configuration using the software requires Ethernet connection of 3. LED
the system to the PC, using the MH201 IP scenario module. 4. Key card detection microswitch

MM00496-b-EN 02/10/2013

78
L
230 V L
50 Hz N N
N
BUS-SCS

L To the fan-coil or
V1 temperature

Wiring diagrams
V2 control system

WWW.BTICINO.COM
TMG3 V3
TMG2 TMG1
Heating
key card switches

B C D Cooling
Ethernet
A
network IG (TMG+ Magnet Contact
earth leak.) Magnet F430R8
Contact
E
Switch HUB
Principle and configuration diagram for a hotel room

ZA = 2
MH201

Protection ZB = 7
To other room line NC contact N = 1
services LOAD = –
3513
MH201
Ethernet
network
Other rooms E49 ZA = 2
MODE
PRI
ZB = 7 ROOM
F +
E49 TYPE = 1 CORRIDOR
PRI: 220 – 240 V~
185 – 175 mA
50/60 Hz –

MM00496-b-EN
SCS: 27 Vdc
600 mA HEAT = 7 RECEPTION
WINDOW ON FAN

SCS
COOL = CEN
CLOSED
H4691 PUMP = – ITEM DESCRIPTION
LN4691 IN = 3 E49 Power supply
0 674 59
OPEN ECO LN4650 Outside the door indicator
PC for room management CLOSED LN4649 Key card switch
LN4653 DND and MUR controls

02/10/2013
LN4652 8-key scenario control
BUS SCS LN4691 Thermostat with display
H4649 MH201 Scenario module IP
LN4649 To other
230 Vac H4653 H4652 devices F430R8 Air conditioning actuator
0 675 65
5 727 35 LN4653 LN4652
0 675 93 0 675 92 General note: the devices listed in the legend are for
Bell 5 722 35 the LivingLight series.
12 Vac/dc – 230 Vac Transformer
max 1A
The general switch GS (TM+EL) must
L1 L A be selected based on the absorption of
R1 = 2 DND MUR the services installed.
R2 = 7 B The TM switch must be selected based
on the power supply used.

GUEST ROOM MANAGEMENT SYSTEM


M = 2 H4650
L = 0 A =9 R1 = 2 A = 9 The TM switch must be selected based
LN4650 C D
A = 1 0 675 90 PL = 9 R2 = 7 PL = 8 on the loads connected.
PL = 1 M1 = CEN M = – M = CEN The actuator to be used depends on
5 722 35

T = 2 DEL1= – LED = – E the type of air conditioning system


M2 = – installed.
DEL2= – If the current supplied by the E49 is not
F sufficient to power the SCS system, it
is possible to use the E46ADCN power
supply.
5 727 35 LN4649
0 675 65 H4649

SCS-BUS SYSTEM
79
TECHNICAL SHEETS

BUS-SCS 0 675 66 H4648


RFID key card switches 5 727 36 LN4648
5 722 36

Description Front view


RFID key card switch for the connection of the power supply to the hotel room (13.56
MHz frequency key card detection). Thanks to the LED backlit slot, the device can be
found in the dark. An automatic switch off delay can also be set.
It can be used with key cards with sizes between 45 mm and 54 mm (ISO).
The device can be configured in two different ways:
- Physical configuration, by inserting the configurators in the appropriate sockets.
-Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration 3
1
has the advantage of offering many more options when compared with the physical
configuration.

Technical data
Power supply from SCS BUS: 18-27 Vdc Rear view
Max. absorption: 6 mA
Absorption in stand by: 5 mA
Operating temperature: (+5) – (+40) °C
RFID key card frequency: 13.56 MHz

Standards, certifications, marks


EN 60669-2-1
EN 50491-5-1 5
EN 50428

Dimensional data Legend


2 flush mounted modules 1. Programming key: Learn IN
2. Programming key: Learn OUT
3. LED
4. Configurator socket
5. Connector for BUS connection

MM00771-a-EN 03/10/2013

80
BUS-SCS 0 675 66 H4648
RFID key card switches 5 727 36 LN4648
5 722 36

Physical configuration Ethernet connection with the system.

There are two modes: Ethernet


- CENTRALIZED, to recall scenarios managed by the scenario programmer. When network
the key card is inserted and removed, the device forwards a signal to the scenario
programmer, which depending on the scenarios set will activate the corresponding MH201
functions programmed. Switch HUB
A = 1-9 (CEN control address)
PL = 1-9 (CEN control address)
M1 = CEN
MH201

DEL1 = no configurator
M2 = no configurator
DEL2 = no configurator Ethernet
network
Note: the insertion of the key card corresponds to “Pushbutton 1” of the control, while
the removal of the key card corresponds to “Pushbutton 2” of the control. BUS-SCS

- SCENARIO, where by inserting the key card a group of actuators is enabled, and an
entrance scenario is activated (through the scenario module), and by removing the
key card an exit scenario is activated (through the scenario module), thanks to which
all the group actuators will switch off and then disable after a set time delay.
A = 1-9 (as scenario module) PC for the configuration
PL = 1-9 (as scenario module)
M1 = 1-8 (activation of the corresponding scenario: see table B) SCENARIO mode programming
DEL1 = 0 - 9 (switching on time delay at the insertion of the key card: see table A)
M2 = no configurator SCENARIO mode programming
DEL2 = 0 - 9 (switching off time delay after the removal of the key card: see table A) This operation is performed to create a link between the key card switch and the
scenario module. The procedure is as follows:
Table A 1) Power the key card switch. Check that the scenario module is in programming
Configurator value Time mode, with the green LED on;
0 0 2) Press and hold down programming key 1 (Learn IN) or 2 (Learn OUT) until the LED
1 1 min starts flashing (approximately 3 seconds);
3) Create the scenario using the system controls and actuators;
2 2 min 4) Once the scenario has been saved, briefly press programming key 1 (Learn IN) or 2
3 3 min (Learn 2) to exit the programming status;
4 4 min 5) The scenario module will also have to exit programming status (see the scenario
5 5 min module technical information).
6 10 min
Cancelling the programming in SCENARIO mode:
7 15 min 1) Power the key card switch. Check that the scenario module is in programming
8 15 sec mode,
9 30 sec with the green LED on;
2) Press and hold down programming key 1 (Learn IN) or 2 (Learn OUT) for 8 seconds.
After 3 seconds the LED will turn on, after a further 5 seconds it will turn off again;
3) Release the key;
Table B 4) The LED flashing, followed by the LED switching off, indicates that the programming
Configurator value Scenario - Group has been cancelled;
1 Scenario-group (Sce1=1, Sce2=9, Gr=1) 5) The scenario module will also have to exit programming status (see the scenario
2 Scenario-group (Sce1=2, Sce2=10, Gr=2) module technical information).
3 Scenario-group (Sce1=3, Sce2=11, Gr=3)
4 Scenario-group (Sce1=4, Sce2=12, Gr=4)
5 Scenario-group (Sce1=5, Sce2=13, Gr=5)
6 Scenario-group (Sce1=6, Sce2=14, Gr=6)
7 Scenario-group (Sce1=7, Sce2=15, Gr=7)
8 Scenario-group (Sce1=8, Sce2=16, Gr=8) 3
1
Note: Sce 1 = scenario activated on insertion
Sce 2 = scenario activated on removal
Gr = actuator group

Configuration with MyHOME_Suite software 2

This is performed using the appropriate application MyHOME_Suite, this mode has
1. Programming key: Learn IN
the advantage of offering many more options when compared with the physical
2. Programming key: Learn OUT
configuration. The configuration using the software requires Ethernet connection of the
3. LED
system to the PC, using the MH201 IP scenario module.

MM00771-a-EN 03/10/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 81


WWW.BTICINO.COM
82
L
230 V L
N
50 Hz N
N
L
BUS-SCS

V1 To the fan-coil or
V2 temperature

Wiring diagrams
control system
V3
TMG2 TMG1 TMG3
Heating
B C D Cooling
TECHNICAL SHEETS

Ethernet A
network IG (TMG+ Magnet Contact
RFID key card switches

earth leak.) Magnet F430R8


Contact

Switch HUB E
Principle and configuration diagram for a hotel room

MH201
ZA = 2
Protection ZB = 7
line NC contact
MH201 N = 1
3513 LOAD = –
To other room
Ethernet PRI
services
network E49 E49 ROOM
PRI: 220 – 240 V~
Other rooms 185 – 175 mA
50/60 Hz
ZA = 2
SCS: 27 Vdc
600 mA MODE CORRIDOR
F ZB = 7
+ RECEPTION
SCS
TYPE = 1

HEAT = 7

MM00771-a-EN
WINDOW ON FAN
ITEM DESCRIPTION
COOL = CEN E49 Power supply
CLOSED H4691 PUMP = – Key card reader outside the door and
LN4691 LN4651
0 674 59 IN = 3
indicators
OPEN ECO 3547 Credit card transponder key card
PC for room management CLOSED LN4648 Transponder key card switch
LN4653 DND and MUR controls

03/10/2013
LN4652 8-key scenario control
BUS SCS LN4691 Thermostat with display
H4648 To other MH201 Scenario module IP
230 Vac LN4648 H4653 H4652 F430R8 Air conditioning actuator
0 675 66 devices
Bell 5 727 36 LN4653 LN4652 F411/1N DIN module 1 relay actuator
12 Vac/dc – 230 Vac Transformer Transformer 5 722 36 0 675 93 0 675 92
max 1A Room door electric General note: the devices listed in the legend are for
lock the LivingLight series.

H4651 The general switch GS (TM+EL) must


L1 L LN4651 DND MUR A be selected based on the absorption of
R1 = 2 0 675 91 2 sec. the services installed.
R2 = 7 The TM switch must be selected based
M = 2 A =9 R1 = 2 A = 9 B on the power supply used.
L = 0 PL = 9 R2 = 7 PL = 8
F411/1N The TM switch must be selected based
A = 1 3547 M1 = CEN M = – M = CEN C D
A = 1
on the loads connected.
PL = 1 DEL1= – LED = –
PL = 1
The actuator to be used depends on
5 722 36

T = 2 M2 = – E the type of air conditioning system


M = PUL DEL2= – installed.
If the current supplied by the E49 is not
F sufficient to power the SCS system, it
is possible to use the E46ADCN power
supply.
5 727 36 LN4648
0 675 66 H4648
BUS-SCS 0 675 93 H4653
DND and MUR flush-mounted control LN4653

Description Front view


Flush mounted control for installation inside the room, for the activation of the “Do Not
Disturb” or “Make Up Room” notifications on the indicator outside the door.
The device can be configured in two different ways:
- Physical configuration, by inserting the configurators in the appropriate sockets.
-Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration
has the advantage of offering many more options when compared with the physical
configuration.

Technical data
BUS/SCS power supply: 18 – 27 Vdc
2
Absorption: max. 7.5 mA
Operating temperature: (+5) – (+40) °C Rear view

Standards, certifications, marks


EN 60669-2-1
EN 50491-5-1
EN 50428 3

Dimensional data Legend


Size: 2 flush mounted modules. 1. LED adjustment/disable pushbutton
2. LED:
AXOLUTE/ARTEOR/CÉLIANE: BLUE: message not active
PURPLE: message active
LIVINGLIGHT: GREEN: message not active
ORANGE: message active
3. Clamps for connection to the BUS
4. Configurator socket

MM00775-a-EN 02/10/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 83


WWW.BTICINO.COM
TECHNICAL SHEETS

BUS-SCS 0 675 93 H4653


DND and MUR flush-mounted control LN4653

Physical configuration LED brightness adjustment

R1
R2 30%
M

R1, R2 = Room address (R1 identifies the tenths; R2 identifies the units) DEFAULT
60% 0%
M = 0 DND and MUR active - 2 x 1 module key covers

DND MUR 100%


PUSH t > 2 s

M = 1 DND control only - 1 double key cover

DND

Configuration with MyHOME_Suite software


This is performed using the appropriate application MyHOME_Suite, this mode has
the advantage of offering many more options when compared with the physical
configuration.
The configuration using the software requires Ethernet connection of the system to the
PC, using the MH201 IP scenario module.

Ethernet connection with the system.

Ethernet
network

MH201
Switch HUB

MH201

Ethernet
network

BUS-SCS

PC for the configuration

MM00775-a-EN 02/10/2013

84
L
L N
230 V
N
50 Hz N
L
BUS-SCS

To the fan-coil or
V1 temperature
control system

Wiring diagrams
V2

WWW.BTICINO.COM
V3
TMG2 TMG1 TMG3
Heating
A D Cooling
Ethernet B C
network IG (TMG+ Magnet Contact
earth leak.) Magnet F430R8
Contact

Switch HUB E
Principle and configuration diagram for a hotel room

ZA = 2
MH201

Protection ZB = 7
To other room NC contact
services line N = 1
MH201
3513 LOAD = –
E49
PRI
DND and MUR flush-mounted control

Ethernet
network F E49
Other rooms PRI: 220 – 240 V~
185 – 175 mA ZA = 2 ROOM
50/60 Hz
SCS: 27 Vdc
600 mA MODE
ZB = 7 CORRIDOR
+
SCS TYPE = 1 RECEPTION

MM00775-a-EN
HEAT = 7
WINDOW ON FAN ITEM DESCRIPTION
COOL = CEN
CLOSED E49 Power supply
H4691 PUMP = –
LN4691 IN = 3 Key card reader outside the door and
0 674 59 LN4651
OPEN ECO
indicators
PC for room management CLOSED 3547 Credit card transponder key card
LN4648 Transponder key card switch

02/10/2013
LN4653 DND and MUR controls
BUS SCS LN4652 8-key scenario control
LN4691 Thermostat with display
H4648 To other
230 Vac LN4648 MH201 Scenario module IP
0 675 66 H4653 H4652 devices F430R8 Air conditioning actuator
Bell 5 727 36 LN4653 LN4652
12 Vac/dc – 230 Vac Transformer Transformer 0 675 93 0 675 92 F411/1N DIN module 1 relay actuator
5 722 36
max 1A Room door electric General note: the devices listed in the legend are for
lock the LivingLight series.
L1 L
H4651 The general switch GS (TM+EL) must be
LN4651 DND MUR
R1 = 2 0 675 91 2 sec. A selected based on the absorption of the
R2 = 7 services installed.
R1 = 2 The TM switch must be selected based

GUEST ROOM MANAGEMENT SYSTEM


M = 2 A =9 A = 9 B
L = 0 PL = 9 R2 = 7 PL = 8 on the power supply used.
F411/1N
A = 1 3547 M1 = CEN M = – M = CEN C D The TM switch must be selected based
A = 1 DEL1 = – LED = – on the loads connected.
PL = 1
0 675 93

PL = 1 M2 = – The actuator to be used depends on the


T = 2 E
M = PUL DEL2 = –
type of air conditioning system installed.
If the current supplied by the E49 is not
F sufficient to power the SCS system, it
is possible to use the E46ADCN power
supply.
LN4653
H4653

SCS-BUS SYSTEM
85
TECHNICAL SHEETS

BUS-SCS 0 675 90 H4650


outside the door indicator LN4650

Description Front view


1 2
Outside the door indicator with "Do Not Disturb" or "Make Up Room" notifications; it
also has a call bell pushbutton and white backlit notification to indicate if someone is
in the room, and the presence of alarm conditions.
If the DND function is active, the call pushbutton is disabled.
The white backlight switch on function can be configured for operating in different
modes. See the physical configuration section "L configurator".
The "Visual alarm notification" function outside the door is only available for systems
with the MH201 device installed, and its programming is only possible using the
MyHOME_Suite software.
4 3
This function is only available for devices with lot number 14w40 or later.
The device can be configured in two different ways:
- Physical configuration, by inserting the configurators in the appropriate sockets.
-Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration Rear view
has the advantage of offering many more options when compared with the physical
configuration.

Technical data 7
BUS/SCS power supply: 18 – 27 Vdc
Absorption in Stand by: 10 mA
6
20 mA max
Relay contact
(activated by the front pushbutton): 12 Vac/dc – 230 Vac
1A max
Operating temperature: 5 – 40 °C

Legend
Standards, certifications, marks
1. DND indicator (red LED ON = DO NOT DISTURB)
EN 60669-2-1
EN 50491-5-1 2. MUR indicator (green LED ON = MAKE UP ROOM)
EN 50428 3. Call pushbutton
4. Room number customisable and backlit area with white notification for:
guest in the room and alarm notification.
Dimensional data
5. Configurator socket
Size: 2 flush mounted modules. 6. Clamps for connection to the BUS
7. NO contact for the activation of the bell. The contact is controlled by the front
pushbutton

MM00774-b-EN 15/01/2015

86
BUS-SCS 0 675 90 H4650
outside the door indicator LN4650

Physical configuration Wiring diagrams


Room 127 bell control diagram
R1 The bell is active while the relevant key on the device is pressed.
R2
M 230 Vac

L
Transformer
R1, R2 = Room address (R1 identifies the tenths; R2 identifies the units) Room bell
12 Vac/dc – 230 Vac
M = 0 for use together with F420 1A max

M = 1 for use together with MH200N


M = 2 for use together with MH201

L = LED functions
L1 L2
R1 = 2 H4650
DND RED MUR
L CONFIGURATOR WHITE BACKLIGHTING LED R2 = 7 LN4650
LED GREEN LED 0 675 90
M = 2
0 ON: busy OFF: free Active Active L = 0
1 ON: busy OFF: free Active Disabled
2 ON: free OFF: busy Active Active
3 ON: free OFF: busy Active Disabled
4 Always ON Active Active
5 Always ON Active Disabled
6 Always OFF Active Active BUS-SCS
7 Always OFF Active Disabled

Software configuration
This is performed using the appropriate application MyHOME_Suite, this mode has
the advantage of offering many more options when compared with the physical
configuration. The configuration using the software requires Ethernet connection of
the system to the PC, using the MH201 IP scenario module.

Ethernet connection with the system.

Ethernet
network

MH201
Switch layer 3

MH201

Ethernet
network
BUS-SCS

PC for the configuration

MM00774-b-EN 15/01/2015

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 87


WWW.PROFESSIONISTI.BTICINO.IT
88
L
L N
230 V N
N
50 Hz
L
BUS-SCS

V1 To the fan-coil or
V2 temperature
control system
V3
TMG2 TMG1 TMG3 Heating
B C D Cooling
TECHNICAL SHEETS

Ethernet A
network IG (TMG+ Magnet Contact
Magnet F430R8
earth leak.) Contact
E
outside the door indicator

Switch layer 3
Principle and configuration diagram for a hotel room

ZA = 2
MH201

Protection NC contact ZB = 7
To other room line N = 1
services
MH201 3513 LOAD = –

Ethernet
network
Other E49
MODE ZA = 2 ROOM
rooms PRI

F + ZB = 7 CORRIDOR
E49

MM00774-b-EN
PRI: 220 – 240 V~
185 – 175 mA
50/60 Hz – TYPE = 1 RECEPTION
SCS: 27 Vdc
600 mA

WINDOW ON FAN
HEAT = 7
SCS COOL = CEN
CLOSED ITEM DESCRIPTION
H4691
LN4691 PUMP = – E49 Power supply
0 674 59 IN = 3 LN4650 Outside the door indicator
OPEN ECO LN4649 Key card switch
PC for room management CLOSED LN4653 DND and MUR controls

15/01/2015
LN4652 8-key scenario control
LN4691 Thermostat with display
BUS SCS
MH201 Scenario module IP
H4649 To other F430R8 Air conditioning actuator
230 Vac LN4649 devices
0 675 65 H4653 H4652 General note: the devices listed in the legend are for
Transformer 5 727 35 LN4653 LN4652 the LivingLight series.
Bell 5 722 35 0 675 93 0 675 92
12 Vac/dc – 230 Vac
max 1A The general switch GS (TM+EL)
A must be selected based on the
absorption of the services installed.
DND MUR The TM switch must be selected
L1 L B based on the power supply used.
R1 = 2 The TM switch must be selected
R2 = 7 C D based on the loads connected.
H4650
M = 2 LN4650 The actuator to be used depends on
A =9 R1 = 2 A = 9
0 675 90

L = 0 0 675 90 E the type of air conditioning system


PL = 9 R2 = 7 PL = 8
A = 1 installed.
M1 = CEN M = – M = CEN
PL = 1 If the current supplied by the E49
DEL1= – LED = –
T = 2 F is not sufficient to power the SCS
M2 = – system, it is possible to use the
DEL2= – E46ADCN power supply.
LN4650
H4650
RFID reader and outside the door indicator 0 675 91 H4651
SCS BUS LN4651

Description Front view


1 2 3
Outside the door indicator with "Do Not Disturb" or "Make Up Room" notification,
call bell pushbutton, RFID key card reader (Mlfare classic ISO 14443), white backlit
notification to indicate if someone is in the room, and the presence of alarm conditions.
The white backlight switch on function can be configured for operating in different
modes. See the physical configuration section "L configurator". 
The "Visual alarm notification" function outside the door is only available for systems
with the MH201 device installed, and its programming is only possible using the
MyHOME_Suite software.
This function, and the compatibility with the Mifare classic ISO 14443 key card,
6 4
including 3547 key cards, are only available for devices with lot number 14w40 or later.
The device can be configured in two different ways: 5
- Physical configuration, by inserting the configurators in the appropriate sockets.
-Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration
has the advantage of offering many more options when compared with the physical
Rear view
configuration.

Technical data
7
BUS/SCS power supply: 18 – 27 Vdc
Absorption: in Stand‑by 10 mA 9
with relay active 20 mA
max. with RFID 55 mA
Relay contact (activated 8
by the front pushbutton): 12 Vac/dc – 230 Vac
1A max
Operating temperature: 5 – 40 °C

Standards, certifications, marks Legend


EN 60669-2-1 1. DND indicator (red LED ON = DO NOT DISTURB)
EN 50491-5-1 2. Green LED ON = reading OK
EN 50428 Red LED ON = reading error
LED flashing = stand alone mode key card programming
3. MUR indicator (green LED ON = MAKE UP ROOM)
4. Call pushbutton (it activates the internal relay)
Dimensional data
5. RFID key card reader
Size: 2 flush mounted modules.
6. Room number customisable and backlit area with white notification for: guest in
the room and alarm notification.
7. Configurator socket
8. Clamps for connection to the BUS
9. NO relay contact; the relay can be used to control:
- bell
- electric door lock
The relay is activated by the front pushbutton.

MM00776-b-EN 20/01/2015

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 89


WWW.BTICINO.COM
TECHNICAL SHEETS

RFID reader and outside the door indicator 0 675 91 H4651


SCS BUS LN4651

Physical configuration Software configuration


This is performed using the appropriate application MyHOME_Suite, this mode has
R1 the advantage of offering many more options when compared with the physical
R2 configuration. The configuration using the software requires Ethernet connection of the
system to the PC, using the MH201 IP scenario module.
M
Ethernet connection with the system.
L
A Ethernet
network
PL
T
MH201
Switch layer 3
R1, R2 = Room address (R1 identifies the tenths; R2 identifies the units)

M = 0 for use together with F420


M = 1 for use together with MH200N MH201

M = 2 for use together with MH201

L = LED functions Ethernet


network
DND RED MUR GREEN BUS-SCS
L CONFIGURATOR WHITE BACKLIGHTING LED
LED LED

0 ON: busy OFF: free Active Active

1 ON: busy OFF: free Active Disabled

2 ON: free OFF: busy Active Active

3 ON: free OFF: busy Active Disabled


PC for the configuration
4 Always ON Active Active

5 Always ON Active Disabled

6 Always OFF Active Active

7 Always OFF Active Disabled

A, PL = door lock actuator SCS address

T = door lock relay timer

Configurator Time

0 1/2 sec

1 1 sec

2 2 sec

3 3 sec

4 4 sec

5 5 sec

6 6 sec

7 7 sec

8 8 sec

9 9 sec

MM00776-b-EN 20/01/2015

90
RFID reader and outside the door indicator 0 675 91 H4651
SCS BUS LN4651

Stand-alone mode key card programming Wiring diagrams


Master key card programming Room 110 bell + electric door lock control diagram
If no master key card has been programmed, at the first start up the DND & MUR The bell is activated by the front pushbutton of the reader and indicator outside the
indicator accepts all the key cards. door.
To start the Master key card programming procedure press the call pushbutton for 10 The electric door lock is activated for a period of 2 seconds by the reader and indicator
seconds and then move the key card close to the reader; this key card will be saved as outside the door following a positive reading of the key card.
Master.
The programming of the Master key card cannot be changed; however the device can
be reset as follows: 230 Vac
- Disconnect the power supply from the device.
- Reconnect the power supply while pressing the call pushbutton for 10 seconds.
NOTE: this procedure deletes all the key cards saved by the device. Transformer
Customer key card programming Transformer
Bell
- Move the Master key card close to the reader; the green LED starts flashing slowly.
- Move the customer key card to save close to the reader, the green LED stays on steady Room door
electric lock
for two seconds. 12 Vac/dc – 230 Vac
- Press the call pushbutton to end the operation (the green LED goes off). 1A max

Deleting all the saved customer key cards 2 sec


- Move the Master key card close to the reader; the green LED starts flashing slowly. F411/1N
- Move the key card close to the reader again, the green LED starts flashing quickly. L1 L
H4651 R1 = 1
- Move the key card close to the reader a third time, the green LED comes on steady for LN4651 R2 = 0
five seconds before switching off.
110
0 675 91 M = 2
L = –
Service key card programming A = 1 A = 1
- Move the Master key card close to the reader; the green LED starts flashing slowly. PL = 1 PL = 1
- Press the call pushbutton; the LED starts flashing orange. T = 2 M = PUL
- Move the service key card to save close to the reader, the orange LED stays on steady
for two seconds.
- Press the call pushbutton to end the operation (the orange LED goes off).
BUS-SCS
Deleting all the service key cards
- Move the Master key card close to the reader; the green LED starts flashing slowly.
- Press the call pushbutton; the LED starts flashing orange.
- Move the Master key card close to the reader again, the LED starts flashing quickly.
- Move the key card close to the reader a third time, the orange LED comes on steady
for five seconds before switching off.
Room 115 electric door lock control diagram
The electric door lock is activated for a period of 3 seconds by the RFID reader following
Programming the key card using the PC and the software a positive reading of the key card. In this mode the front pushbutton is disabled.
Programming key cards using the PC and the relevant software provides further
functions in addition to the basic ones available in stand-alone mode programming: 230 Vac
validity settings, guest information, scheduled accesses...
This procedure is only possible using item MH201.
Transformer

Room door electric lock


12 Vac/dc – 230 Vac
1A max R1 = 1
L1 L R2 = 5
M = 2
L = –
H4651 A = –
LN4651 PL = –
0 675 91 T = 3

BUS-SCS

MM00776-b-EN 20/01/2015

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 91


WWW.BTICINO.COM
92
L
L N
230 V N
50 Hz N
L SCS BUS
V1 To the fan-coil or
V2 temperature
control system
V3
TMG2 TMG1 TMG3
Heating
A B C D Cooling
TECHNICAL SHEETS

Ethernet
network IG (TMG+
Magnet Contact
earth leak.) Magnet F430R8
Contact

Switch layer 3
E
ZA = 2
Principle and configuration diagram for a hotel room

MH201
ZB = 7
Protection
To other room line NC contact N = 1
MH201 services LOAD = –
3513
E49
PRI
Ethernet F
network E49
ROOM
PRI: 220 – 240 V~
Other 185 – 175 mA
ZA = 2
50/60 Hz
SCS: 27 Vdc
rooms 600 mA MODE ZB = 7 CORRIDOR
RFID reader and outside the door indicator

+ TYPE = 1 RECEPTION
SCS

MM00776-b-EN
HEAT = 7 ITEM DESCRIPTION
WINDOW ON FAN
COOL = CEN E49 Power supply
CLOSED H4691 PUMP = – Key card reader outside the door and
IN = 3
LN4651
LN4691 indicators
0 674 59 3547 Credit card transponder key card
OPEN ECO LN4648 Transponder key card switch
PC for room management CLOSED
LN4653 DND and MUR controls

20/01/2015
LN4652 8-key scenario control
LN4691 Thermostat with display
BUS SCS MH201 Scenario module IP
H4648 F430R8 Air conditioning actuator
To other
230 Vac LN4648 devices F411/1N DIN module 1 relay actuator
0 675 66 H4653 H4652
Bell Transformer 5 727 36 LN4653 LN4652
12 Vac/dc – 230 Vac Transformer 5 722 36 0 675 93 0 675 92 General note: the devices listed in the legend are for
max 1A Room door electric the LivingLight series.
lock
L1 L The general switch GS (TM+EL) must
R1 = 2 H4651 A be selected based on the absorption of
R2 = 7 LN4651 DND MUR the services installed.
0 675 91 2 sec. The TM switch must be selected based
M = 2 B
L = 0 on the power supply used.
A =9 R1 = 2 A = 9 The TM switch must be selected based
A = 1 PL = 9 R2 = 7 PL = 8 C D on the loads connected.
PL = 1 F411/1N
0 675 91

M1 = CEN M = – M = CEN The actuator to be used depends on


T = 2 3547
A = 1 DEL1= – LED = – E the type of air conditioning system
PL = 1 M2 = – installed.
M = PUL DEL2= – If the current supplied by the E49
F is not sufficient to power the SCS
system, it is possible to use the
E46ADCN power supply.
LN4651
H4651
8-key multifunction control 0 675 92 H4652
SCS BUS LN4652

Description Front view


Flush mounted multifunction control, with 8 backlit keys in the centre section, where
the icons indicating the functions allocated to the keys can be found.
The device can be configured in two different ways:
- Physical configuration, by inserting the configurators in the appropriate sockets.
-Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration
has the advantage of offering many more options when compared with the physical
configuration. 1 1
Irrespective of the mode implemented, an A/PL address must always be assigned to
the control.
In can be programmed in 4 operating modes:
- The self-learning mode (cyclical or non cyclical) gives the possibility of associating
to each key the majority of the typical controls of the automation, sound, and video
2
door entry (staircase lights, door lock, call to the floor, door lock and camera cycling)
systems, in addition to the auxiliary controls.
- The scenario mode gives the possibility of recalling, programming and deleting 8
scenarios of a scenario module. Rear view
- The swivelling mode gives the possibility of driving 4 light points of shutters in
succession (room or group). 4
- CEN mode gives the possibility of using the control together with scenario
programmer MH200N or MH201.

Related items 5
3541 - 0 675 95 A5 sheets with symbol customisations, BLACK 3
3542 - 0 675 96 A5 sheets with symbol customisations, WHITE
4
For the customisation of the sheets, it is possible to use the tool found in the
MyHOME_Suite configuration software, which can be downloaded from the website:
www.homesystems-legrandgroup.com.

Technical data Legend


Power supply from BUS: 18 – 27 Vdc 1. Keys
Absorption: with LEDs OFF: 5 mA 2. Customisable label
with LEDs ON at 100%: 20 mA
3. Clamps for connection to the BUS
Operating temperature: (+5) – (+40) °C
4. Configurator socket
5. Programming pushbutton for self-learning and scenario modes

Standards, certifications, marks


EN 60669-2-1
EN 50491-5-1
EN 50428

Dimensional data
Size: 2 flush mounted modules

MM00778-a-EN 16/09/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 93


WWW.BTICINO.COM
TECHNICAL SHEETS

8-key multifunction control 0 675 92 H4652


SCS BUS LN4652

Physical configuration 3) Scenario module M = 1 – 2


This operating mode can only be used if the system includes a scenario module F420;
the matching is achieved by assigning to both the items the same address, identified
A by A=0-9 and PL=1-9. The user can create, cancel, or modify the scenarios found in the
PL scenario module, and can recall them using the keys.
The procedure gives the possibility of saving up to 16 scenarios using two devices.
M
LED The following table shows the correspondence between the number of the scenario
A room saved in the scenario module, and the keys of the control in the possible configurations:
PL light point
M mode (see the dedicated section)
LED backlight setting Key 1 Key 2
(see the dedicated section)
Key 3 Key 4
Configurator A
room address Key 5 Key 6
Configurator PL
Key 7 Key 8
light point address
Configurator M
Key number M=1 M=2
1) Self-learning mode M=0 Key 1 Scenario 1 Scenario 9
This mode of operation gives the possibility of associating an individual control to any Key 2 Scenario 2 Scenario 10
key of the device. It is possible to create, delete or modify each control. The device Key 3 Scenario 3 Scenario 11
may be configured using any A/PL address already present in the system, or a unique Key 4 Scenario 4 Scenario 12
address not used by other devices.
Key 5 Scenario 5 Scenario 13
Key 6 Scenario 6 Scenario 14
Programming the keys Key 7 Scenario 7 Scenario 15
The procedure to associate each key to a different control is as follows: Key 8 Scenario 8 Scenario 16
1) Press and release the programming key on the back of the device; the backlighting
LEDs will flash slowly; Programming a scenario with the F420
2) Press the key to program within 20 seconds: the LEDs start flashing much quicker, For the programming of the scenario, the procedure is as follows:
indicating the activation of the programming mode; 1) The self-learning configuration of the scenario module, item F420, must be enabled
3) Set the control to associate to the key using the controls and/or the corresponding (to do so press the self-learning pushbutton, so that the corresponding LED turns
actuator; the LEDs will start flashing slowly; green; if the LED is red, self-learning is disabled);
4) At this point it is possible to repeat points 2 and 3 for all the keys, including those 2) Press and release the programming key on the back of the multifunction control; the
that have already been associated, to change their association; LEDS start flashing slowly (1 sec. ON and 1 sec. OFF);
5) Quickly press the programming pushbutton, or wait 20 seconds to exit the 3) Within 20 seconds press the key corresponding to the scenario to program on the
programming procedure. multifunction control; its LEDs start flashing quickly, indicating the activation of the
programming mode;
Cancelling the programming of the keys 4) Set the scenario, using the controls and/or actuators of the system;
1) Press and release the programming key; the backlight LEDs will flash slowly; 5) Press the programming key of the multifunction control again to exit programming
2) Within 20 seconds press and hold down for 4 seconds the key to cancel; from now and complete the procedure: the LEDs start flashing slowly again; it is now possible to
on the key cancelled will no longer activate any control until programmed again; repeat points 2, 3, and 4 for all the scenarios; the same procedure must also be used
3) The LEDs come on at full power for 4 seconds, after which it will be possible to to change the scenarios already set;
repeat point 2 to cancel the programming of other keys; 6) Press and quickly release the self-learning pushbutton on the F420 module, or wait 20
4) Press and quickly release the programming pushbutton, or wait 20 seconds to exit seconds to complete the procedure (red LED on).
the programming procedure.
NOTE: To delete the programming of all the keys at the same time, press and quickly F420
release the programming key; the LEDs start flashing slowly; press and hold down
again for 10 seconds the pushbutton on the back: the LEDs come on for approximately
4 seconds, confirming the cancellation of all programming.

ART.F420

2) Non-cyclical self-learning mode M=6


This mode is a variant of the self-learning mode (M=0), in which, however, the keys DEL
never work cyclically." Therefore, if for example, the ON of an actuator or dimmer is programming block/ scenario cancellation
learnt, the couple of keys is configured automatically to switch on or increase the light release key key
intensity level for the left key, and switch off or decrease the level of intensity for the
scenario/learning
right key. If, on the other hand, a single function is learnt (e.g. recalling of a scenario), reset LED
the other key of the pair remains without function, or retains the previous function. The
programming status LED
device may be configured using any A/PL address already present in the system, or a
unique address not used by other devices.

MM00778-a-EN 16/09/2013

94
8-key multifunction control 0 675 92 H4652
SCS BUS LN4652

Deleting a scenario LED configurator


To delete the scenario, the procedure is as follows: Setting the backlight intensity
1) The F420 scenario module must be in configuration mode with self-learning enabled; The configurator in the LED socket gives the possibility of setting the backlight at the
2) Press and release the programming key of the multifunction control; the LEDS start desired level; see table:
flashing slowly (1 sec. ON and 1 sec. OFF);
3) Within 20 seconds press and hold down for 4 seconds the key of the scenario to be LED configurator Brightness level
cancelled on the multifunction control;
0 default setting = 30%
4) The LEDs flash quickly for 4 seconds, after which it will be possible to repeat point 2 to
delete the other programming. 1 level 10 %
5) Press and quickly release the programming pushbutton on the back of the control, or 2 level 15 %
wait 20 seconds to exit the deleting procedure.
3 level 20 %
NOTE: to reset the whole memory, it will be necessary to directly act on the
scenario module: press “DEL” for ten seconds, after enabling the scenario module for 4 level 25 %
programming. 5 level 30 %
6 level 40 %
4) Swivelling modes M=0/I; ↑↓; ↑↓M 7 level 50 %
These modes ensure quick installation without the need for further learning, or
scenario modules, enabling the control of 4 light points or shutters with consecutive 8 level 60 %
addresses. 9 level 80 %
The A PL address is the light point or shutter controlled by the first pair of keys (the OFF level OFF
keys are paired horizontally), the subsequent pairs controls the subsequent light points
or shutters. ON level 100 %
If the Amb or Gr configurators are connected to A, in the same way, the 4 pairs of
keys control consecutive rooms or groups starting from the one indicated by the PL
configurator.

Possible function Value of M configurator Configuration using the software in a typical hotel system

ON/OFF control: ON control with the left key, OFF control 0/I This is performed using the appropriate application MyHOME_Suite, this mode has
with the right key. the advantage of offering many more options when compared with the physical
For point-to-point controls the key perform the ON/OFF configuration. The configuration using the software requires Ethernet connection of
function with a short pressure and the system to the PC, using the MH201 IP scenario module.
the adjustment with an extended pressure: for the other Ethernet connection with the system.
controls, only ON/OFF are performed
Ethernet
Control (UP/DOWN for shutters): up and down control, ↑↓ network
until fully open or closed

Monostable control (UP/DOWN for shutters): up and ↑↓M


MH201
down control, for the time the key is pressed Switch HUB

MH201

5) Scenario programmer mode, M=CEN


The matching between a scenario configured in the scenario programmer MH200N or
MH201, and the corresponding controls keys of the multifunction control, is completed
during the programming of the scenario itself using the dedicated software. Ethernet
network
Always assign to the control a unique A/PL address on the system (it must not be
used by any other device installed on the BUS); the A=0, PL=0 configuration is not BUS-SCS
acceptable. This operating mode can only be used if the system includes a scenario
programmer (MH200 or MH201).

PC for room
management

MM00778-a-EN 16/09/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 95


WWW.BTICINO.COM
TECHNICAL SHEETS

IP scenario module MH201


BUS-SCS

Description Front view


The IP scenario module is a device of the Hotel range for the management of the room 1
and the common areas.
One MH201 must be used for each room or common area.
For systems with over 100 rooms, or common areas, the IP Server F458 device must
also be used.
It's main functions are: 2
- Key card management: 3
1) room access management (key cards saved). Using the supervision software, it
is possible to manage the saving of the key cards (if the external reader is present)
used for opening the door with two different profiles (Users or Service). For each
key card saved, it is possible to associate a validity end date, 3 access time profiles,
and a maximum number of accesses. MH201

The date of validity can only be associated for user key cards, not for service ones.
The access time profiles and the maximum number of accesses can only be
associated to common areas.
For more details refer to the supervision software manual.
- Management of the room functions:
1) MAKE UP ROOM. If inside the room MUR is pressed on the appropriate
control (LN4653-H4653-0 675 93), the IP scenario module updates the notification
to all the display units (LN4651-H4651-0 675 91), also notifying the event occurred 4
to the supervision software.
Using the CEN operating mode, also other devices can send MUR notifications.
2) DO NOT DISTURB. If inside the room the DND key is pressed on the
appropriate control (LN4653-H4653-0 675 93), the IP scenario module updates the Top view Bottom view
notification to all the display units (LN4651-H4651-0 675 91), also notifying the
event occurred to the supervision software.
Using the CEN operating mode, also other devices can send MUR notifications.
3) Room alarms. If an alarm is activated (e.g. bathroom pull cord), the device
notifies the supervision software, from where it will then be reset.
If enabled, the notification will also be sent to the display outside the door.
4) Management of the room contacts. Technical contact for forwarding 4
information and alarm notifications to the supervision software (e.g. window or
refrigerator door open).
5) Remote thermostat contact. 1
6) Presence management. The presence of someone in the room is notified by
the key card switch (LN4849-H4648-0 675 66-05 727 36-05 722 36); the IP
scenario module sees the notification and forwards it to all the notifying units
(LN4651-H4651-0 675 91), and to the supervision software.
- Gateway for the configuration of the devices installed inside the room. The IP
scenario module performs the gateway function to enable the configuration of the
devices installed inside the room using the MyHOME_Suite.
- Communication with the supervision software
- Scenario management. The device can manage up to 50 scenarios as follows: Legend
a) 5 start triggers.
b) 1 stop trigger. 1. Ethernet data network RJ45 connector
c) 1 condition “ONLY IF”. 2. LED: LED: red/green bi-colour LED
d) 10 actions. Notification: flashing red, 1 sec. ON / 1 sec. OFF, acquiring
The scenarios are saved using the MyHOME_Suite software. the Ethernet network address configuration
- Management of lights as memory module. The device follows the status of the Flashing green, 1 sec. ON / 3 sec. OFF, Ethernet network
actuators, and if no network is detected, the status is reset. configuration acquired
- It saves the events occurred inside the room in a log that can be downloaded using 3. Pushbutton:
the supervision software. - pressure of the pushbutton until it starts flashing green at start-up:
set-up of fixed IP 192.168.1.5, Subnet Mask 255.255.255.0
- extended pressure for 30 seconds:
deletion of the log (all the saved events)
4. Clamps for connection to the SCS BUS

MM00777-b-EN 15/01/2015

96
IP scenario module MH201
BUS SCS

Technical data
Power supply: 18 – 27 Vdc
Absorption: 30 mA
Operating temperature: 5 – 40 °C

Standards, certifications, marks


EN 60669-2-1
EN 50491-5-1
EN 50428

Dimensional data
Size: 1 DIN modules

Configuration
The configuration of the scenarios can be completed using the "MyHOME_Suite"
software:
It is possible to save up to 50 scenarios.
Always using the software, it is possible to change the basic settings of the device:
- Name: max. 16 characters
- Open Password: default 12345 (max 9 characters)

Putting into operation


Pressing the pushbutton until it starts flashing green will set the configuration of the
device with the fixed IP address:
IP 192.168.1.5
Subnet Mask 255.255.255.0

MM00777-b-EN 15/01/2015

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 97


WWW.BTICINO.COM
TECHNICAL SHEETS

IP scenario module MH201


BUS-SCS

Typical wiring diagram (for programs with over 100 rooms or common areas refer to the technical guide)
TO THE OTHER FLOORS

3 FLOOR
rd To the other rooms
H4648 ROOM 301
LN4648
To the floor services 0 675 66 H4653 H4691 H4652
5 727 36 LN4653 LN4691 LN4652
MH201 5 722 36 0 675 93 0 674 59 0 675 92
MODE

DND MUR

Switch layer 3 E49


FAN

PRI: 220 – 240 V~

BUS SCS
185 – 175 mA
50/60 Hz
SCS: 27 Vdc
600 mA
MH201

SCS

H4651
LN4651
E49 301 0 675 91

2nd FLOOR To the other rooms


H4648 ROOM 201
LN4648
To the floor services 0 675 66 H4653 H4691 H4652
5 727 36 LN4653 LN4691 LN4652
MH201 5 722 36 0 675 93 0 674 59 0 675 92
MODE

DND MUR
FAN

E49
Switch layer 3 PRI: 220 – 240 V~
185 – 175 mA
50/60 Hz BUS SCS
SCS: 27 Vdc
600 mA
MH201

SCS

H4651
LN4651
E49 201 0 675 91

1st FLOOR To the other rooms


H4648 ROOM 101
LN4648
To the floor services 0 675 66 H4653 H4691 H4652
5 727 36 LN4653 LN4691 LN4652
MH201 5 722 36 0 675 93 0 674 59 0 675 92
MODE

DND MUR

Switch layer 3
FAN
E49
PRI: 220 – 240 V~

BUS SCS
185 – 175 mA
50/60 Hz
SCS: 27 Vdc
600 mA
MH201

SCS

H4651
LN4651
E49 101 0 675 91

RECEPTION
PC + software for room 348402
Ethernet network management

USB cable
3547

MM00777-b-EN 15/01/2015

98
L
L
230 V N
N
50 Hz N
L
BUS SCS
V1 To the fan-coil or
V2 temperature

Wiring diagrams
control system
V3

WWW.BTICINO.COM
TMG3
TMG2 TMG1 Heating
D Cooling
IP scenario module

Ethernet
A B C
network IG (TMG+ Magnet Contact
earth leak.) Magnet F430R8
Contact

Switch layer 3
E
ZA = 2
Principle and configuration diagram for a hotel room

MH201 ZB = 7
To other room Protection NC contact N = 1
services line
MH201 LOAD = –
3513
E49
PRI ROOM
Ethernet
network F E49
ZA = 2 CORRIDOR
Other PRI: 220 – 240 V~
185 – 175 mA
50/60 Hz RECEPTION
SCS: 27 Vdc
600 mA MODE ZB = 7
rooms
+ TYPE = 1
SCS
ITEM DESCRIPTION
– HEAT = 7

MM00777-b-EN
E49 Power supply
WINDOW ON FAN
COOL = CEN
CLOSED
Key card reader outside the door and
H4691 PUMP = – LN4651
3
indicators
LN4691 IN =
0 674 59 3547 Credit card transponder key card
OPEN ECO LN4648 Transponder key card switch
PC for room management
CLOSED LN4653 DND and MUR controls
LN4652 8-key scenario control

15/01/2015
LN4691 Thermostat with display
BUS SCS MH201 Scenario module IP
H4648 F430R8 Air conditioning actuator
To other
230 Vac LN4648 devices F411/1N DIN module 1 relay actuator
0 675 66 H4653 H4652
Bell Transformer Transformer 5 727 36 LN4653 LN4652
12 Vac/dc – 230 Vac 5 722 36 0 675 93 0 675 92 General note: the devices listed in the legend are for
max 1A Room door electric the LivingLight series.
lock
L1 L
R1 = 2 H4651 The general switch GS (TM+EL) must
R2 = 7 LN4651 DND MUR A be selected based on the absorption of
0 675 91 2 sec. the services installed.
M = 2
The TM switch must be selected based

GUEST ROOM MANAGEMENT SYSTEM


L = 0 A =9 R1 = 2 A = 9 B on the power supply used.
A = 1 PL = 9 R2 = 7 PL = 8
F411/1N C D The TM switch must be selected based
PL = 1 M1 = CEN M = – M = CEN on the loads connected.
3547
T = 2 A = 1 DEL1= – LED = – The actuator to be used depends on
PL = 1 M2 = – E the type of air conditioning system
M = PUL DEL2= – installed.
If the current supplied by the E49
F is not sufficient to power the SCS
system, it is possible to use the
E46ADCN power supply.
MH201

SCS-BUS SYSTEM
99
TECHNICAL SHEETS

Scenario module F420

Description
Up to 16 scenarios may be saved in the scenario module, with up to 100 controls each. The
scenarios can also give door entry and video door entry controls for one-family systems
to switch on the staircase lights and open the door lock. If installed in large systems
with F422 interface in logical expansion, the module can save automation controls for
the system where it is installed. On the front cover of the item there are two keys and
two LEDs. The first key (padlock) locks or unlocks the programming procedure avoiding
involuntary operations such as cancelling the scenarios and the corresponding LED
indicates the status: green programming possible, red programming blocked, orange DEL
temporary block. The second key (DEL) cancels all the scenarios, the LED underneath 6 1
indicates that the cancellation has taken place or that the device is performing the
learning procedure.
5 2

4 3
Technical data
Power supply from SCS BUS: 27 Vdc
Operating power supply with SCS BUS: 18 – 27 Vdc Front view
Absorption: 20 mA
Operating temperature: 0 – 40 °C
Size: 2 DIN modules Legend
1. Scenario cancellation key
2. Scenario/learning reset LED
3. Configurator socket
4. BUS
5. Programming status LED
6. Programming lock/unlock key

MQ00067-d-EN

100
Scenario module F420

Configuration

If the device is installed in a MyHOME system, it can be configured in two ways: completely, press and hold down the corresponding key for approximately 10 seconds. To
- PHYSICAL CONFIGURATION: by connecting the configurators to the appropriate sockets. erase the entire memory keep the DEL pushbutton on the Scenario module pressed for 10
- Configuration performed using MyHOME_Suite software, which can be downloaded seconds, the yellow “reset scenarios” LED flashes quickly. Once the operations have been
from the website www.homesystems-legrandgroup.com. performed lock the programming by pressing the lock/unlock key for at least 0.5 seconds, so
For the list of modes and the corresponding meanings refer to the indications of this that the corresponding LED becomes red.
data sheet, and to the "Function description" section of the MyHOME_Suite software.
NOTES:
The combination of the scenario module with a control device is ensured by assigning Inside the system itself one Scenario module can be programmed at a time as the
to both items the same address. This is identified by the configurators with a numeric other devices are temporarily locked; during this phase the “programming status”
value for position A = 0 – 9 and position PL = 1 – 9. Several scenario modules may be LED becomes orange signalling the temporary Lock. During the learning procedure
installed in one system, allocating a different address to each module. and when there are timed controls or group controls, the Scenario module does not
save events for 20 seconds. You must thus wait before continuing with creating the
Scenario programming scenario. During the scenario learning procedure only the changes of status are saved.
To program, change or delete a scenario you need to enable programming module It is important to configure the scenario module with a different A and PL address to
F420 so that the status LED is green (press the locking/unlocking key on the scenario that of an actuator. If the configuration is wrong the Programming status LED flashes
module for at least 0.5 seconds) and then continue with the following steps: ORANGE. In case of “virtual” configuration the LED flashes RED.

1) press one of the four control keys to which the scenario should be associated to for
3 seconds and the corresponding LED will start flashing;
2) set the scenario using the corresponding controls for the various Automation,
Temperature control, Sound system, etc. functions;
3) confirm the scenario by briefly pressing the corresponding key on the special
control to exit the programming mode;
4) to change a scenario, or to create new ones to use with the other keys, repeat the
procedure starting from point 1.
To recall an already set scenario, briefly pressing the corresponding key on the control is
enough.

If the module does not receive any input for 30 minutes from the start of the learning
procedure, programming will automatically be interrupted. If you want to delete a scenario

1.1 Addressing

Address type Virtual configuration (MYHOME_Suite) Physical configuration


Point-to-point Room 0-9 A=0-9
Light point 1-9 PL = 1-9

MQ00067-d-EN

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 101


WWW.BTICINO.COM
TECHNICAL SHEETS

BUS-SCS F458
server IP

Description Front view


The server IP device is part of the devices of the hotel offer and must be used when
1
designing or installing systems with over 100 rooms, or areas with over 100 MH201
installed.

Default configuration
Network configuration IP = 192.168.1.51
Netmask: 255.255.255.0 2
DHCP and DNS default range in
the “MyHOME_Suite” software vers. 2.0.91: 192.168.1.52 – 192.168.5.49 3
Password OPEN: 12345

Technical data
Power supply: 18 – 30 Vdc
Absorption: 55 mA max DC
Minimum consumption: 1.3 W
Maximum consumption: 3.3 W
Holding date and time without power supply: 48 hours
Operating temperature: 5 – 45 °C 4

Standards, certifications, marks Legend


EN 60669-2-1 1. RJ45 connector for Ethernet LAN 10/100 Mbit
EN 50491-5-1 2. Mini-USB connector for the configuration using the PC and software update
EN 50428
3. LED notifications
System LED: it comes on when connecting the power supply, and then it goes off.
When it later comes back on steady, it means that the device is
Dimensional data
working correctly
Size: 6 DIN modules Speed LED: speed of connection to the network:
ON = 100 Mbit
OFF = 10 Mbit
Configuration Link LED: when ON, it indicates that the Ethernet network has been found
The device must be configured using the “MyHOME_Suite” software. 4. Power supply connection clamps (recommended 346020)

MM00857-a-EN 15/01/2015

102
BUS-SCS F458
server IP

Wiring diagrams

Typical diagram of a system with less than 100 areas (rooms + common areas) and one supervision PC.

Hotel Rooms
ROOM 99 ROOM 100

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 3 ROOM 4

MH201 MH201

Switch layer 3

MH201

ROOM 1 ROOM 2

MH201 MH201

Switch layer 3

MH201 MH201

Interface PMS
Hotel management
supervision software

Switch layer 3

Layer 3 switch or Router

Dedicated BTicino/Legrand VLAN

Ethernet network

MM00857-a-EN 15/01/2015

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 103


WWW.BTICINO.COM
TECHNICAL SHEETS

BUS-SCS F458
server IP

Wiring diagrams

Typical diagram of a system with 100 to 500 areas (rooms + common areas) and one supervision PC.

Hotel Rooms
ROOM 499 ROOM 500

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 99 ROOM 100

MH201 MH201

Switch layer 3

MH201
MH201

ROOM 1 ROOM 2

MH201 MH201

Switch layer 3

MH201 MH201

Interface PMS
Hotel management
supervision software

Switch layer 3

Layer 3 switch or Router

230 V

PR I

346020
PRI: 220 - 240V~
175-165mA
50/60Hz
1-2: 27Vdc
600mA

DC
1- 2
Power supply
346020
IP SERVER
F458
Dedicated BTicino/Legrand VLAN

Ethernet network

MM00857-a-EN 15/01/2015

104
BUS-SCS F458
server IP

Wiring diagrams

Typical diagram of a system with up to 500 areas (rooms + common areas) and up to 10 supervision PCs.

Hotel Rooms
ROOM 499 ROOM 500

MH201 MH201

Switch layer 3

MH201 MH201

ROOM 99 ROOM 100

10th PC
Hotel management
MH201 MH201
supervision software

Switch layer 3

MH201 MH201

ROOM 1 ROOM 2
1st PC
Hotel management
supervision software
Supervision server

MH201 MH201

Switch layer 3

MH201 MH201

Interface PMS

Switch layer 3

Layer 3 switch or Router


230 V

PR I

346020
PRI: 220 - 240V~
175-165mA
50/60Hz
1-2: 27Vdc
600mA

DC
1- 2
Power supply
346020
IP SERVER
F458
Dedicated BTicino/Legrand VLAN

Ethernet network

MM00857-a-EN 15/01/2015

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 105


WWW.BTICINO.COM
TECHNICAL SHEETS

Thermostat with display H4691 067459


LN4691 64170

Description
Thermostat with display for the control of the room temperature in temperature control 1 2 3
systems.
This device can be used both if a temperature control central unit is present or not
present; when appropriately configured it can be used as:
- MyHOME temperature control system probe;
- Hotel room thermostat; 4
- Residential system thermostat. 12 MODE
It has 4 keys that can be used to select the desired temperature and the various operating
5
modes; when used with fan-coils it can manage the fan speed.
11 +
The thermostat can manage different operating modes: both automatic and manual, in
addition to the Eco, Comfort, Antifreeze/Thermal protection, and OFF. 6
It can also be used in mixed heating/cooling systems, if the two functions are available –
at the same time on the same system.
A contact is also available on the back of the device, to change the operating mode of the 7
thermostat (e.g. window contact, summer/winter switching, etc.). FAN

10 9 8
Technical data 13
Power supply from SCS BUS: 18 – 27 Vdc
Absorption: 14 mA with display off
16 mA with low brightness display
30 mA with high brightness display
Operating temperature: (+5) – (+40) °C
Size: 2 flush mounted modules
Recommended installation height: 150 cm from the ground
Controllable loads: On/Off, Open/Close, 3-point
or 0 – 10 V valves.
2-tube and 4-tube fan-coils with
On/Off, 3-point, or 0 – 10 V valves.
Gateway Climaveneta.
Fil Pilote.

Correlated devices 15 14
The thermostat must be used with the following actuator devices: Legend
- F430/2: ON/OFF 2-relay actuator;
- F430/4: ON/OFF 4-relay actuator; 1. Heating function
- F430R8: ON/OFF 8-relay actuator; 2. Cooling function
- F430R3V10: ON/OFF 3-relay actuator with 2 x 0 – 10 V outputs; 3. Operating mode icons
- F430V10: actuator with 2 x 0 – 10 V outputs; 4. MODE key: a short pressure changes the mode of operation of the device;
- F430FP: actuator for Fil Pilote devices. an extended pressure (unless used as MyHOME probe) changes the function.
5. + key: increase the set value
6. – key: decrease the set value
7. FAN key: set the fan coil speed on 3 levels + automatic
8. Heating/cooling on indicator
9. Fan coil speed indicator, 3 levels
10. Fan coil in automatic mode indicator
11. Measured (thermometer symbol ON) / set (thermometer symbol OFF temperature
indicator
12. Unit of measure: °C or °F
13. Configurator socket
14. Connection to the BUS
15. Local contact

MM00789-a-EN 12/09/2013

106
Thermostat with display H4691 067459
LN4691 64170

Configuration COOL = Cooling load. For the configurations from 1 to 9 configure the correspond-
ing actuator with N=2. In case of CEN configurator the actuator will be N=1.
The thermostat can be configured:
- Through physical configuration, by connecting the configurators to the appropriate Parameter/setting Physical
sockets on the back of the device. This quick mode is ideal for basic functions, and gives configuration
the possibility of setting, in addition to the zone address, also a heating load, a cooling
load, up to 2 system pumps, and a quick function for the remote contact. No device 0
- Using MyHOME_Suite (*), where a dedicated wizard will guide the user through the ON/OFF valve 1
procedure for correctly configuring the device. The MyHOME_Suite software gives the
possibility of customising the device and provides a higher degree of functionality, Open/Close valve 2
such as:
- The possibility of changing some default parameters (select the unit of measure for the 2-tube fan-coil with ON/OFF valve 3
temperature, change the permitted operating temperature, manage the backlighting Gateway 4
level, disable some device pushbuttons, etc.).
- Configure a higher number of loads (up to 9 heating and/or cooling actuators and 9 2-tube fan-coil with 3-point or 0-10V valve 6
pumps), and assign slave probes (max. 9). 4-tube fan-coil with ON/OFF valves 7
- Enable advanced functions, like automatic switching between heating and cooling.
- Manage dedicated fan-coil settings (e.g. fan speed change threshold settings, or fan 4-tube fan-coil with 3-point or 0–10 V valves 8
activation delay, etc.). 3-point or 0-10V valve 9
- Set a delay or a timeout for the actions generated by the status change of the remote
contact (in addition to allowing a higher number of combinations than through the Same load managed for heating and cooling (2) CEN
physical configuration).
(2) in case of common heating/cooling load, the configurator set in the HEAT position
will have to be different from 0 (no device) or 5 (Fil Pilote).
1.1 ADDRESSING
PUMP= Number and types of pumps to control
By connecting two configurators with value 0-9 in the ZA and ZB sockets, it is possible to set
the device address. The controlled actuators will have to be configured with the same address. Parameter/setting Physical
configuration
Socket Function Physical configuration
No device 0
ZA/ZB Zone address from 01 to 99
Pump with N= 1 For heating (3) 1
1.2 OPERATING MODE
Pump with N= 2 For cooling 2
By configuring the positions TYPE, HEAT, COOL, PUMP and IN, it is possible to set the
desired operating modes and the types of loads to manage. Pump with N= 1 For heating + 3
pump with N= 2 For cooling(3)
TYPE = Type of operation
Parameter/setting Physical configuration Pump with N= 1 For both heating and cooling (3) 4
MyHOME temperature control system 0
(3) With this mode it is not possible to define the Fil Pilote device in the HEAT position
probe (1)
(configurator 5)
Hotel room thermostat 1
Residential system thermostat 2 IN= Function activated by the change of status of the contact on the back of the device
(1) If the device is used as a MyHOME system probe with temperature control central Contact status/function Physical
unit, the subsequent positions HEAT, COOL, and PUMP must not be configured. The
configuration
settings for actuators and pumps will be defined directly from the central unit menu.
OPEN CLOSED
HEAT = Heating load. Configure the corresponding actuator with N=1. Contact disabled Contact disabled 0
Parameter/setting Physical Thermal protection Return to the previous status 1
configuration
OFF Return to the previous status 2
No device 0
ON/OFF valve 1 ECO Return to the previous status 3
Open/Close valve 2 COMFORT Return to the previous status 4
2-tube fan-coil with ON/OFF valve 3 Switch to heating (4) Switch to cooling 5
Gateway 4
(4) This function cannot be selected when the device is used as probe in MyHOME
Fil Pilote 5
systems with temperature control central unit.
2-tube fan-coil with 3-point or 0-10V valve 6
4-tube fan-coil with ON/OFF valves 7 Note (*): - software downloadable from the website:
4-tube fan-coil with 3-point or 0–10 V valves 8 www.homesystems-legrandgroup.com
3-point or 0-10V valve 9 - the functions are available from version 1.3.

MM00789-a- EN 12/09/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 107


WWW.BTICINO.COM
TECHNICAL SHEETS

DIN module F428


contact interface

Description
This device lets you integrate traditional control devices (switches, pushbuttons, etc.) in
advanced systems with BUS operating logic.
Therefore, it is possible to extend the use of the Lighting Management system in rooms 1
where traditional systems are already present or in historic and prestigious rooms
whereby the complete or partial remaking of the electric system would entail heavy C N1 N2
masonry work. The old but valuable switch with its no longer compliant wiring can
therefore continue to be used with it, as the connection to the load to be controlled is
carried out safely by connecting it with its respective interface with no-voltage contact.
Contact N1 controls light point PL1, contact N2 controls light point PL2.
It is possible to connect:
- two N/O (normally open) and N/C (normally closed) traditional switches or pushbuttons; 5
- a two-way switch. 4
The device is fitted with 2 LEDs to signal contact closure, programming/deletion, and the N1 N2
status of the control devices.
2

Technical data
Power supply from SCS BUS: 27 Vdc 3
Operating power supply with SCS BUS: 18 – 27 Vdc
Absorption: 9 mA
Dissipated power with maximum load: 0.2 W Legend
1. Clamps for the connection to traditional devices
2. Configurator socket (warning, to be used only in MY HOME systems with physical
Dimensional data configuration).
Size: 2 DIN modules 3. BUS
4. LED
5. Key

Configuration
If the device is installed in a MyHOME system, it can be configured in two ways: - two N/O (normally open) and N/C (normally closed) traditional switches or pushbuttons;
- PHYSICAL CONFIGURATION: by connecting the configurators to the appropriate sockets. - a two-way switch.
- Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration List of functions
has the advantage of offering many more options when compared with the physical
configuration. The device create the following functions:
For the list of modes and the corresponding meanings refer to the indications of this 1. LIGHT CONTROL
data sheet, and to the "Function description" section of the MyHOME_Suite software. 2. AUTOMATION CONTROL
When used as a component of the Lighting Management system, use the specific types 3. LOCK/UNLOCK OF DEVICES
of configuration (Plug&go, Project&Download). 4. SCENARIO MODULE CONTROL
The interface consists of two independent control units, which are identified with the 5. PROGRAMMED SCENARIO ACTIVATION
positions PL1 and PL2 in the physical configuration and the term Module 1 and Module 2 6. PLUS LIGHTING MANAGEMENT SCENARIO ACTIVATION
in the MYHOME_Suite virtual configuration. The two units can send: 7. PLUS PROGRAMMED SCENARIO ACTIVATION
- controls to two actuators for two independent loads (On, Off or adjustment) identified 8. SOUND SYSTEM CONTROL
with the address PL1 and PL2 and the mode specified in M or;
- a control to the F420 scenario module; For the configuration modes see the next pages.
- a double control intended for a single load (motor for shutters Up-Down, curtains Open-
Close) identified with the address PL1=PL2 and specified Configuration mode M. The
interface has an LED for indicating proper operation and three terminals for connection
to traditional devices such as:

MQ00283-c-EN 23/07/2013

108
DIN module F428
contact interface

Physical configuration

The interface consists of two independent control units, which are identified with the positions N1 and N2. The two units can send:
- controls to two actuators for two independent loads (On, Off or adjustment) identified with the address PL1 and PL2 and the mode specified in M
A PL1 PL2 M SPE or;
- a control to the F420 scenario module;
- a double control intended for a single load (motor for shutters Up-Down, curtains Open-Close) identified with the address PL1=PL2 and specified
Configuration mode M.

Selecting the function

To configure the contact numbers use MYHOME_Suite virtual configuration

1. Light control

1.1 Addressing
Address type Virtual configuration (MYHOME_Suite) Physical configuration
Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General General A=GEN

With the virtual configuration, for the room, group and general controls, you can set a You can also configure the "Installation level" and the "Destination level".
light point address for the return of the load status.

1.2 Mode

1.2.1 ON/OFF control missing in XLS


Virtual configuration (MYHOME_Suite) Physical configuration
Function Parameter / setting
Type of contact to N1 and N2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Cyclical SPE=0, M=0
ON SPE=0, M=ON
OFF SPE=0, M=OFF
Cyclical (only NO contact) SPE=1, M=7
Pushbutton SPE=0, M=PUL
ON with key in N2, OFF with key in N1 SPE=0, M=O/I
Timed ON 0.5sec SPE=0, M=8
2sec SPE=8, M=1
30sec SPE=0, M=7
1min SPE=0, M=1
2min SPE=0, M=2
3min SPE=0, M=3
4min SPE=0, M=4
5min SPE=0, M=5
10min SPE=8, M=2
15min SPE=0, M=6

For timed ON with a period of from 0-255 hours, 0-59 minutes and 0-59 seconds, use MyHOME_Suite virtual configuration

MQ00283-c-EN 23/07/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 109


WWW.BTICINO.COM
TECHNICAL SHEETS

DIN module F428


contact interface

1.2.2 ON/OFF control and ADJUSTMENT (Point-to-Point only):


Virtual configuration (MYHOME_Suite) Physical configuration
Parameter / setting
Cyclical ON/OFF and ADJUSTMENT SPE=0, M=O
ON/OFF when pressing briefly and adjustment when holding down
ON with button in N2, OFF with button in N1 and DIMMER when held down SPE=0, M=O/I
ON with adjustment at 10% SPE=3, M=1
ON with adjustment at 20% SPE=3, M=2
ON with adjustment at 30% SPE=3, M=3
ON with adjustment at 40% SPE=3, M=4
ON with adjustment at 50% SPE=3, M=5
ON with adjustment at 60% SPE=3, M=6
ON with adjustment at 70% SPE=3, M=7
ON with adjustment at 80% SPE=3, M=8
ON with adjustment at 90% SPE=3, M=9

For the functions of "Cyclic with custom point-to-point adjustment", "Cyclic with adjustment", "Custom dimmer OFF without adjustment", "ON with custom adjustment",
custom adjustment", "Cyclic dimmer without adjustment", "Custom dimmer ON without "OFF with custom adjustment", use MyHOME_Suite virtual configuration.

1.2.3 Flashing control


When an actuator receives a flashing control, it implements it by closing and opening
the relay for a time equal to T that can be configured as shown in the table.
Combine it with a control configured OFF to switch it off.
Virtual configuration (MYHOME_Suite) Physical configuration
Parameter / setting
Flashing 0.5 s SPE=2, M=0
Flashing 1 s SPE=2, M=1
Flashing 1.5 s SPE=2, M=2
Flashing 2 s SPE=2, M=3
Flashing 2.5 s SPE=2, M=4
Flashing 3 s SPE=2, M=5
Flashing 3.5 s SPE=2, M=6
Flashing 4 s SPE=2, M=7
Flashing 4.5 s SPE=2, M=8
Flashing 5 s SPE=2, M=9

For flashing with a period of from 5.5 to 8 seconds, use MyHOME_Suite virtual configuration

MQ00283-c-EN 23/07/2013

110
DIN module F428
contact interface

2. Automation control

2.1 Addressing

Address type Virtual configuration (MYHOME_Suite) Physical configuration


Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General general A=GEN

With the virtual configuration, for the room, group and general controls, you can set a
light point address for the return of the load status. You can also configure the "Installation
level" and the "Destination level".

missing in XLS
2.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to N1 and N2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Bistable control PL1=PL2 SPE=0 M=
Monostable control PL1=PL2 SPE=0 M=M

3. Lock/Unlock of devices

3.1 Addressing

Address type Virtual configuration (MYHOME_Suite) Physical configuration


Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General General A=GEN

3.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to N1 and N2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Disable SPE=1, M=1
Enable SPE=1, M=2

To configure the "Installation level" and the "Destination level" and use
MYHOME_Suite virtual configuration

MQ00283-c-EN 23/07/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 111


WWW.BTICINO.COM
TECHNICAL SHEETS

DIN module F428


contact interface

3. Lock/Unlock of devices

3.1 Addressing

Address type Virtual configuration (MYHOME_Suite) Physical configuration


Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General General A=GEN

3.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to N1 and N2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Disable SPE=1, M=1
Enable SPE=1, M=2

To configure the "Installation level" and the "Destination level" and use
MYHOME_Suite virtual configuration

MQ00283-c-EN 23/07/2013

112
DIN module F428
contact interface

4. Scenario module control

4.1 Addressing

Function Virtual configuration (MYHOME_Suite) Physical configuration


Room (of scenario module) 0-10 A=1-9
Light point (of scenario module) 0-15 PL1, PL2=0-9

NOTE: PL2 must be equal to PL1, or not be configured (in which case the button connected to
terminal PL2 is disabled)

4.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to N1 and N2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Scenario activation and modification
Scenario No. 1-16 SPE=61), M=1-8
Scenario activation
Scenario No. 1-16 SPE=42), M=1-8

NOTE: For flashing with a period of from 5.5 to 8 seconds, use MyHOME_Suite virtual configuration NOTE 2): With SPE=4 it is only possible to call up the scenario saved in module item F420.
NOTE 1): With SPE=6 you can call and program scenarios within module F420. M=1-8: group of M=1-8: group of scenarios to be controlled (see table).
scenarios to be controlled (see table).

M First PL1 contact Second PL2 contact Scenario programming


1 1 2
To program, change or delete a scenario you need to enable programming module
2 3 4 F420 so that the status LED is green (press the locking/unlocking key on the scenario
3 5 6 module for at least 0.5 seconds) and then continue with the following steps:
4 7 8
1) press one of the four special control keys to which the scenario should be associated
5 9 10 to for 3 seconds and the corresponding LED will start flashing;
6 11 12
2) set the scenario using the corresponding controls for the various Automation,
7 13 14 Temperature control, Sound system, etc. functions;
8 15 16
3) confirm the scenario by briefly pressing the corresponding key on the special control
A=0-9 and PL1=1-9 are the room and the light point of the scenario module to be controlled. PL2 to exit the programming mode;
must be equal to PL1 or not be configured (in which case the second contact is disabled).
4) to change a scenario, or to create new ones to use with the other keys, repeat the
procedure starting from point 1. To recall an already set scenario, briefly pressing
the corresponding key on the control is enough. If you want to delete a scenario
completely, press and hold down the corresponding key for approximately 10 seconds.

MQ00283-c-EN 23/07/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 113


WWW.BTICINO.COM
TECHNICAL SHEETS

DIN module F428


contact interface

5. Programmed scenario activation

Enabling keys for sending a control to the scenario programmer MH200N. the scenario to be activated, the control can be connected at any point in the system
The address of the assigned control in positions A and PL must be unique and match (local bus or riser).

5.1 Addressing

Virtual configuration (MYHOME_Suite) Physical configuration


Addressing type
Room 0-10 A=1-9
Light point 0-15 PL1, PL2=1-9

NOTE: If PL1=PL2 the two buttons connected to the interface activate two different scenarios.
If PL1≠PL2 the two buttons activate the same scenario.

5.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Type of contact to N1 and N2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
N1 pushbutton 0-31 SPE=0 M=CEN
N2 pushbutton 0-31 SPE=0 M=CEN

6. Plus lighting management scenario activation

For the configuration refer to MyHOME_Suite

7. Plus programmed scenario activation

To configure the address 1 - 2047 of the scenario and the number of pushbuttons 0 - 31
on the control device, use MYHOME_Suite virtual configuration

MQ00283-c-EN 23/07/2013

114
DIN module F428
contact interface

8. Sound system control

This mode allows you to control the amplifiers and the sources of the Sound System.

8.1 Addressing

You can manage a single amplifier (point-to-point control), some amplifiers (room control) and all the amplifiers in the system (general control).

Virtual configuration (MYHOME_Suite) Physical configuration


SPE=8
Addressing type Parameter / setting
Point-to-point Room 0-9 0-9
Audio point 0-9 0-9
Room Room 0-9 A=AMB
PF=0-9
General General A=GEN

8.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to N1 and N2 clamps Normally open SPE=7
Normally closed SPE=0
ON/volume + SPE=5, M=0 on N1 pushbutton
OFF/volume - SPE=5, M=0 on N2 pushbutton
Change track SPE=5, M=1 on N1 pushbutton
Click the source SPE=5, M=1 on N2 pushbutton
Follow me YES SPE=5, M=0
PL2=0 follow me, PL2=1-4 source
NO
For the “Cyclical ON/OFF” function and to select sources 1-9 use the MYHOME_Suite virtual configuration

MQ00283-c-EN 23/07/2013

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 115


WWW.BTICINO.COM
TECHNICAL SHEETS

DIN module F428


contact interface

Wiring diagram

M
DIN module Actuator
interface

C N1 N2
1 2 3 4
1 2 3 4

C1 C2

N1 N2

BUS SCS

MQ00283-c-EN 23/07/2013

116
Basic contact interface 3477

Description
This device lets you integrate traditional control devices (switches, pushbuttons, etc.) in A
advanced systems with BUS operating logic. PL1
PL2 1
Therefore, it is possible to extend the use of the BUS system in rooms where traditional M
systems are already present or in historic and prestigious rooms whereby the complete SPE

or partial remaking of the electric system would entail heavy masonry work. The old but
valuable switch with its no longer compliant wiring can therefore continue to be used
2
with it, as the connection to the load to be controlled is carried out safely by connecting
it with its respective interface with no-voltage contact.
Contact PL1 controls light point PL1, contact PL2 controls light point PL2. The interface PL1 PL2 C
has a LED for signalling it is working properly and three cables for connecting to
traditional devices. This device is made in a Basic enclosure and therefore features a
compact size and can be used in flush-mounted boxes, junction boxes, shutter boxes and
ducts. Particularly advantageous is the installation inside junction boxes, positioning
the item at the back of the flush-mounted box, behind lowered automation devices or
behind conventional devices (pushbuttons, switches, etc.). 4 3

Legend
1. Configurator socket (warning, to be used only in MY HOME systems with physical
Technical data configuration)
Power supply from SCS BUS: 27 Vdc 2. LED
Operating power supply with SCS BUS: 18 – 27 Vdc 3. Cables for the connection to traditional devices
Absorption: 3.5 mA 4. BUS

Dimensional data
Size: basic module

Configuration

If the device is installed in a MyHOME system, it can be configured in two ways: List of functions
- PHYSICAL CONFIGURATION: by connecting the configurators to the appropriate sockets.
- Configuration using the MyHOME_Suite software, which can be downloaded from The device create the following functions:
the website www.homesystems-legrandgroup.com; this last type of configuration 1. LIGHT CONTROL
has the advantage of offering many more options when compared with the physical 2. AUTOMATION CONTROL
configuration. 3. LOCK/UNLOCK OF DEVICES
For the list of modes and the corresponding meanings refer to the indications of this data 4. SCENARIO MODULE CONTROL
sheet, and to the "Function description" section of the MyHOME_Suite software. 5. PROGRAMMED SCENARIO ACTIVATION
When used as a component of the Lighting Management system, use the specific types of 6. PLUS PROGRAMMED SCENARIO ACTIVATION
configuration (Plug&go, Project&Download). 7. AUXILIARY CONTROL
The interface consists of two independent control units, which are identified with the 8. SOUND SYSTEM CONTROL
positions PL1 and PL2 in the physical configuration and the term Module 1 and Module 2
in the MYHOME_Suite virtual configuration. The two units can send: For the configuration modes see the next pages.
- controls to two actuators for two independent loads (On, Off or adjustment) identified
with the address PL1 and PL2 and the mode specified in M or;
- a control to the F420 scenario module;
- a double control intended for a single load (motor for shutters Up-Down, curtains Open-
Close) identified with the address PL1=PL2 and specified Configuration mode M. The
interface has an LED for indicating proper operation and three terminals for connection
to traditional devices such as:
- two N/O (normally open) and N/C (normally closed) traditional switches or pushbuttons;
- a two-way switch.

MQ00272-c-EN 07/06/2014

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 117


WWW.BTICINO.COM
TECHNICAL SHEETS

Basic contact interface 3477

Selecting the function

To configure the contact numbers use MYHOME_Suite virtual configuration

1. Light control
1.1 Addressing
Address type Virtual configuration (MYHOME_Suite) Physical configuration
Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General General A=GEN

Installation and destination level:


The special control can also be used in systems where there are SCS/SCS interfaces (F422). or more actuators located on the BUS of another interface (destination level).
By installing the control on the BUS of an interface (installation level), you can control one

Function Virtual configuration (MYHOME_Suite) Physical configuration


Destination level Local Bus 1-15 I= 1-9
Riser Bus riser I=CEN missing in XLS
Complete system all the system I=0

NOTE: With the virtual configuration, for the room, group and general controls, you can set a light
point address for the return of the load status

1.2 Mode

1.2.1 ON/OFF control


Virtual configuration (MYHOME_Suite) Physical configuration
Function Parameter / setting
Type of contact to PL1 and PL2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Cyclical SPE=0, M=0
ON SPE=0, M=ON
OFF SPE=0, M=OFF
Cyclical (only NO contact) SPE=1, M=7
Pushbutton SPE=0, M=PUL
ON with key in PL2, OFF with key in PL1 SPE=0, M=O/I
Timed ON 0.5sec SPE=0, M=8
2sec SPE=8, M=1
30sec SPE=0, M=7
1min SPE=0, M=1
2min SPE=0, M=2
3min SPE=0, M=3
4min SPE=0, M=4
5min SPE=0, M=5
10min SPE=8, M=2
15min SPE=0, M=6

For timed ON with a period of from 0-255 hours, 0-59 minutes and 0-59 seconds, use
MyHOME_Suite virtual configuration
MQ00283-c-EN
MQ00272-c-EN 07/06/2014

118
Basic contact interface 3477

1.2.2 ON/OFF control and ADJUSTMENT (Point-to-Point only):


Virtual configuration (MYHOME_Suite) Physical configuration
Parameter / setting
Cyclical ON/OFF and ADJUSTMENT SPE=0, M=O
ON/OFF when pressing briefly and adjustment when holding down
ON with button in PL2, OFF with button in PL1 and DIMMER when held down SPE=0, M=O/I
ON with adjustment at 10% SPE=3, M=1
ON with adjustment at 20% SPE=3, M=2
ON with adjustment at 30% SPE=3, M=3
ON with adjustment at 40% SPE=3, M=4
ON with adjustment at 50% SPE=3, M=5
ON with adjustment at 60% SPE=3, M=6
ON with adjustment at 70% SPE=3, M=7
ON with adjustment at 80% SPE=3, M=8
ON with adjustment at 90% SPE=3, M=9

For the functions of "Cyclic with custom point-to-point adjustment", "Cyclic with adjustment", "Custom dimmer OFF without adjustment", "ON with custom adjustment",
custom adjustment", "Cyclic dimmer without adjustment", "Custom dimmer ON without "OFF with custom adjustment", use MyHOME_Suite virtual configuration.

1.2.3 Flashing control


When an actuator receives a flashing control, it implements it by closing and opening
the relay for a time equal to T that can be configured as shown in the table.
Combine it with a control configured OFF to switch it off.

Virtual configuration (MYHOME_Suite) Physical configuration


Parameter / setting
Flashing 0.5 s SPE=2, M=0
Flashing 1 s SPE=2, M=1
Flashing 1.5 s SPE=2, M=2
Flashing 2 s SPE=2, M=3
Flashing 2.5 s SPE=2, M=4
Flashing 3 s SPE=2, M=5
Flashing 3.5 s SPE=2, M=6
Flashing 4 s SPE=2, M=7
Flashing 4.5 s SPE=2, M=8
Flashing 5 s SPE=2, M=9

For flashing with a period of from 5.5 to 8 seconds, use MyHOME_Suite virtual configuration

MQ00272-c-EN 07/06/2014

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 119


WWW.BTICINO.COM
TECHNICAL SHEETS

Basic contact interface 3477

2. Automation control

2.1 Addressing

Address type Virtual configuration (MYHOME_Suite) Physical configuration


Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General general A=GEN

Installation and destination level:


The special control can also be used in systems where there are SCS/SCS interfaces (F422). or more actuators located on the BUS of another interface (destination level).
By installing the control on the BUS of an interface (installation level), you can control one

Function Virtual configuration (MYHOME_Suite) Physical configuration


Destination level Local Bus 1-15 I= 1-9
Riser Bus riser I=CEN missing in XLS
Complete system all the system I=0
NOTE: With the virtual configuration, for the room, group and general controls, you can set a light
point address for the return of the load status

2.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to PL1 and PL2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Bistable control PL1=PL2 SPE=0 M=
Monostable control PL1=PL2 SPE=0 M=M

3. Lock/Unlock of devices

3.1 Addressing

Address type Virtual configuration (MYHOME_Suite) Physical configuration


Point-to-point Room 0-10 A=1-9
Light point 0-15 PL1, PL2=0-9
Room 0-10 A=AMB
Group 1-255 A=GR
General General A=GEN

MQ00272-c-EN 07/06/2014

120
Basic contact interface 3477

3.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to PL1 and PL2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Disable SPE=1, M=1
Enable SPE=1, M=2

To configure the "Installation level" and the "Destination level" and use MYHOME_Suite
virtual configuration

4. Scenario module control

4.1 Addressing

Function Virtual configuration (MYHOME_Suite) Physical configuration


Room (of scenario module) 0-10 A=1-9
Light point (of scenario module) 0-15 PL1, PL2=0-9

NOTE: PL2 must be equal to PL1, or not be configured (in which case the button connected to
terminal PL2 is disabled)

4.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to PL1 and PL2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
Scenario activation and modification
Scenario No. 1-16 SPE=61), M=1-8
Scenario activation
Scenario No. 1-16 SPE=42), M=1-8

For flashing with a period of from 5.5 to 8 seconds, use MyHOME_Suite virtual NOTE 1): With SPE=6 you can call and program scenarios within module F420. M=1-8: group of
configuration scenarios to be controlled (see table).
NOTE 2): With SPE=4 it is only possible to call up the scenario saved in module item F420. M=1-8:
group of scenarios to be controlled (see table).

M First PL1 contact Second PL2 contact Scenario programming


1 1 2 To program, change or delete a scenario you need to enable programming module F420
2 3 4 so that the status LED is green (press the locking/unlocking key on the scenario module
for at least 0.5 seconds) and then continue with the following steps:
3 5 6
1) press one of the four special control keys to which the scenario should be associated to
4 7 8
for 3 seconds and the corresponding LED will start flashing;
5 9 10
2) set the scenario using the corresponding controls for the various Automation,
6 11 12 Temperature control, Sound system, etc. functions;
7 13 14
3) confirm the scenario by briefly pressing the corresponding key on the special control
8 15 16 to exit the programming mode;
A=0-9 and PL1=1-9 are the room and the light point of the scenario module to be controlled. PL2 4) to change a scenario, or to create new ones to use with the other keys, repeat the
must be equal to PL1 or not be configured (in which case the second contact is disabled). procedure starting from point 1. To recall an already set scenario, briefly pressing the
corresponding key on the control is enough. If you want to delete a scenario completely,
press and hold down the corresponding key for approximately 10 seconds.

MQ00272-c-EN 07/06/2014

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 121


WWW.BTICINO.COM
TECHNICAL SHEETS

Basic contact interface 3477

5. Programmed scenario activation

Enabling keys for sending a control to the scenario programmer MH200N. scenario to be activated. The control can be connected at any point in the system (local
The address of the assigned control in positions A and PL must be unique and match the bus or riser).

5.1 Addressing

Virtual configuration (MYHOME_Suite) Physical configuration


Addressing type
Room 0-10 A=1-9
Light point 0-15 PL1, PL2=1-9

NOTE: If PL1=PL2 the two buttons connected to the interface activate two different scenarios.
If PL1≠PL2 the two buttons activate the same scenario.

5.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Type of contact to PL1 and PL2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
PL1 pushbutton 0-31 SPE=0 M=CEN
PL2 pushbutton 0-31 SPE=0 M=CEN

6. Plus lighting management scenario activation

For the configuration refer to MyHOME_Suite

7. Plus programmed scenario activation

To configure the address 1 - 2047 of the scenario and the number of pushbuttons 0 - 31
on the control device, use MYHOME_Suite virtual configuration

8. Auxiliary control

For the configuration refer to MyHOME_Suite

MQ00272-c-EN 07/06/2014

122
Basic contact interface 3477

9. Sound system control

This mode allows you to control the amplifiers and the sources of the Sound System.

9.1 Addressing

You can manage a single amplifier (point-to-point control), some amplifiers (room control) and all the amplifiers in the system (general control).

Virtual configuration (MYHOME_Suite) Physical configuration


Addressing type Parameter / setting
Point-to-point Room 0-9 0-9
Audio point 0-9 0-9
Room Room 0-9 A=AMB
PF=0-9
General General A=GEN

9.2 Mode

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Type of contact to PL1 and PL2 clamps Normally Open (NO) SPE=0
Normally Closed (NC) SPE=7
ON/volume + SPE=5, M=0 (for pushbutton in PL1)
OFF/volume - SPE=5, M=0 (for pushbutton in PL2)
Change track SPE=5, M=1 (for pushbutton in PL1)
Click the source SPE=5, M=1 (for pushbutton in PL2)

For the “Cyclical ON/OFF” function and to select sources 1-9 use the MYHOME_Suite virtual configuration

Follow me mode

Enables, upon powering the amplifier, activating the last source switched on.

Virtual configuration (MYHOME_Suite) Physical configuration


Function Parameter / setting
Switch back on from the last source YES YES M=0
NO Definition of the source 1-4 M=1÷4 1)

NOTE 1): indicates the sound source to be activated before switching on the amplifier.

MQ00272-c-EN 07/06/2014

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 123


WWW.BTICINO.COM
TECHNICAL SHEETS

Basic contact interface 3477

Example:

By properly configuring the interface, the following functions are performed:


M=1 Cycle source/Cycle track mode
M=0 ON/OFF mode
N1 contact: source cycling
Contact in PL1: N2 contact: track cycling
Briefly pressing sends out the following sequence:
- ON sources, PL2 indicates the source to be activated before switching on the amplifier. In this operating mode:
If PL2=0 source 1 is turned on (follow-me mode)
- ON of the A/PL1 amplifier Room controls
A=1-9 is the amplifier room
On holding down:
- For point-to-point controls if the amplifier is already on, only the volume is adjusted General controls
(VOL+); if the amplifier is off, the switch-on sequence is sent first. A=GEN for general controls
- For GEN or AMB controls only the volume is adjusted. PL1=PL2=0

Contact in PL2:
Briefly pressing sends the OFF control for the A/PL1 amplifier
Pressing and holding down adjusts the volume (VOL-)

In this operating mode:

Point-Point control
A=1-9 amplifier room
PL1=0-9 audio point of the amplifier

Room control
A=AMB
PL1=1-9 room of amplifiers where the control is directed

General control
A=GEN
PL1=0
PL2=1-4 indicates the source to be activated before switching on the amplifier.
If PL2=0 follow-me mode is turned on

Wiring diagram

A
PL1
Basic interface
PL2
M
SPE
Old type actuator

PL1 PL2 C
1 2 3 4
1 2 3 4

Old type switch C1 C2

BUS SCS

MQ00272-c-EN 07/06/2014

124
SCS/BUS cable (grey) L4669 - L4669/500

Description
This cable is used for the distribution of the power supplies and the operating signals to
all system devices.
The cable consists of a grey external sheathing and two twisted flexible conductors with
a section of 0.35 mm2, one blue and one white.
It is sold in 2 different types of coils:
- 100 m coil item L4669
- 500 m coil item L4669/500
The cable has 300/500 V insulation. Using the clear clamp protections included in all the
devices, the systems can also be installed in the same boxes and ducts as the power lines
(110 Vac, 127 Vac and 230 Vac).

The grey BUS/SCS cable is not suitable for underground installation even in
appropriate conduits.

Technical data Installation notes


Insulation voltage: 300/500 V Although on a construction point of view the grey cable guarantees 300/500 V category
Underground installation: NO electrical insulation, the correct operation of the devices is not guaranteed in the
External sheath colour: grey (RAL 7001) following cases when installed together with the energy cables:
Diameter of the external sheath: 5.5 +/- 0.1 mm - industrial environments,
Thickness of the external sheath: 0.8 mm - in residential/service sector environments, when the power cables provide power
Material of the external sheath: PVC (RZ) supply to:
Number of internal conductors 2 sheathed unshielded twisted flexible conductors. - lifts,
Colour of internal conductors: white and blue - inverters
Thickness of the internal conductor sheath: 0.60 mm - pumps,
Material of the internal conductor sheath: PVC (R2) - motors and controlled motors,
Conductor material: red electrolytic copper - metal iodines lamps.
Conductor section: 0.35 mmq (12 x 0.20 mmq)
Operating temperature: (-15) – (+70) °C
Max. short circuit temperature: 150°C
Coil length: 100 m or 500 m

Standards, certifications, marks


Standards of reference - the cable meets the requirements of the standards: EN60811,
EN50289, EN50290, EN60228, EN50265-2-1, EN50395, EN50396 as described in the IMQ
CPT 062 document.

Marks otained:

BT00289-b-EN

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 125


WWW.BTICINO.COM
TECHNICAL SHEETS

BUS/SCS AV (white) cable 336904

Description
This cable is used to distribute all the power supplies and operating signals to the BUS
devices of the system.
It consists of a white external sheath and two 50 mm2 section brown and brown/white
flexible twisted conductors. It is sold in 200 m coils.
Therefore, it is suitable to be used in:
- Free air installation, inside trunking, trays and conduits
- Inside masonry walls, in appropriate conduits
- Underground, in appropriate conduits

The white SCS-BUS cable is suitable for underground installation in appropriate


conduits.

Technical data Installation notes


Insulation voltage: 450/750 V Cable underground installation
Underground installation: YES (see installation notes) The 336940 BUS/SCS cable can be installed underground (protected inside appropriate
Colour of external sheath: white (RAL 9010) conduits), together with other signal cables, for voltages <50V.
Diameter of the external sheath: 5.0 +/- 0.1 mm Installation of cable 336904 together with power cables with energies >50V is strictly
Thickness of the external sheath: 0.7 mm forbidden. Failure to comply with the installation requirements shall entitle BTicino to
Material of the external sheath: PVC (RZ) reject all liabilities on the operation of the systems installed.
Number of internal conductors 2 sheathed unshielded twisted flexible conductors.
Colour of internal conductors: brown - brown/white Cohabitation with other cables
Thickness of the internal conductor sheath: 0.40 mm Although the construction of the white cable guarantees the necessary electrical
Diameter of the internal conductor sheath: 1.70 mm insulation for cohabitation with 450/750V system cables, there is no guarantee of
Material of the internal conductor sheath: LDPE polyethylene immunity from electromagnetic disturbance, which may occur when the cable is
Conductor material: red electrolytic copper installed inside the same conduits as the energy cables.
Conductor section: 0.50 mmq (16 x 0.20 mmq) It is therefore strongly recommended that the white BUS/SCS cable and the power
Operating temperature: (-15) – (+70) °C cables are installed in different conduits.
Coil length: 200 m

Standards, certifications, marks


Standards of reference - the cable meets the requirements of the standards: EN60811,
EN50289, EN50290, EN60228, EN50265-2-1, EN50395, EN50396 as described in the IMQ
CPT 062 document.

Marks otained:

BT00660-a-EN

126
BUS/SCS AV (white) halogen free cable L4669HF

Description
This white BUS-SCS cable has been purposely designed and manufactured for installation
in areas with particularly strong fire hazards. Produced without halogens, the cable will
burn without releasing toxic substances or heavy, dense smoke, significantly increasing
the safety level.
This cable is used to distribute all the power supplies and operating signals to the BUS
devices of the system.
It consists of a white external sheath and two 50 mm2 section brown and brown/white
flexible twisted conductors. It is sold in 200 m coils.
Therefore, it is suitable to be used in:
- Free air installation, inside trunking, trays and conduits
- Inside masonry walls, in appropriate conduits
- Underground, in appropriate conduits
Installation notes
The white SCS-BUS cable is suitable for underground installation in appropriate
Cable underground installation
conduits.
The 336940 BUS/SCS cable can be installed underground (protected inside appropriate
conduits), together with other signal cables, for voltages <50V.
Technical data Installation of cable 336904 together with power cables with energies >50V is strictly
Insulation voltage: 450/750 V forbidden. Failure to comply with the installation requirements shall entitle BTicino to
Underground installation: YES - protected by appropriate conduits reject all liabilities on the operation of the systems installed.
Colour of external sheath: white (RAL 9010)
Diameter of the external sheath: 5.2 +/- 0.1 mm Cohabitation with other cables
Thickness of the external sheath: 0.8 mm Although the construction of the white cable guarantees the necessary electrical
Material of the external sheath: LDFRPE Thermoplastic quality M1, hardness 95 A Shore insulation for cohabitation with 450/750V system cables, there is no guarantee of
Number of internal conductors 2 sheathed unshielded twisted flexible conductors. immunity from electromagnetic disturbance, which may occur when the cable is
Colour of internal conductors: brown - brown/white installed inside the same conduits as the energy cables.
Thickness of the internal conductor sheath: 0.45 mm It is therefore strongly recommended that the white BUS/SCS cable and the power
Material of the internal conductor sheath: LDPE polyethylene cables are installed in different conduits.
Conductor material: red electrolytic copper
Conductor section: 0.52 mmq (7 x 0.308 mmq)
Operating temperature: (-15) – (+70) °C
Max. short circuit temperature: 150°C
Coil length: 200 m

Standards, certifications, marks


Standards of reference - the cable meets the requirements of the standards: UL13,
UL1581, EN60811, EN50289, EN50290, EN60228, EN50265-2-1, EN50395, EN50396 as
described in the IMQ CPT 062 document.

Marks otained:

BT00522-b-EN

GUEST ROOM MANAGEMENT SYSTEM SCS-BUS SYSTEM 127


WWW.BTICINO.COM
NOTES

128
GUEST ROOM MANAGEMENT SYSTEM NOTES 129
WWW.BTICINO.COM
NOTES

130
BTicino offers a specific system
solution for all needs.
GUEST ROOM Designed to guarantee the best
MANAGEMENT SYSTEM welcoming and control service without
overlooking the environmental
A complete aspect, Guest Room Management

range meeting System brings together two aspects:


the supervision, managed by Hotel
all specific needs personnel, and the management of the
room by the Customer. Two separate
worlds, that are however in constant
communication.

2
BTicino SpA
Viale Borri, 231

www.bticino.com
21100 Varese - Italy

BTicino SpA reserves at any time the right to modify the contents of this booklet and to
communicate, in any form and modality, the changes brought to the same. AD-EXOD15SAG/GB - Version 07/2015
GUEST ROOM
MANAGEMENT SYSTEM
Guide for design and installation

TECHNOLOGY
WITH SCS-BUS
INTEGRATED SOLUTIONS

You might also like