Straight Through Joints for Plastic Insulated Cables

up to 36KV

Salient Features:
 Pre-designed components for electrical stress control,
reinstatement of insulation, screen and corrosion protection.
 Quick to install.
 Light in weight and hence not affected by soil subsidence.
 Quick re-entry for access to the cores to facilitate cable fault
localisation in urban distribution network.
 Inner extruded cable sheath restored against specific
customer requirement.
 Lends easily to cross bonded connection for 1 core cables.
 Can be energised immediately after completion.
 Type tested to stringent international standards.

 Single kit caters to a range of 3 cable sizes and hence reduces


inventory.
3 Core HT XLPE Cable Straight Through Joint
1.Outer Sheath 2.Black Mastic 3.S.S.Hose Clips 4.Black Mastic 5.Stress Grading Mastic
6.Semi-conductive Tube 7.Insulating Tubes 8. Stress Control Tube 9.Ferrule 10.Stress
Grading Mastic 11.XLPE Insulation 12.Semicon 13.Tinned Copper wire Mesh 14. Metallic
Screen 15. Tinned Copper Braid 16. G.I.Cannister 17. Corrosion Protection Tube 18. Tinned
Copper wire Mesh 19. Bare Copper Braid for Screen Continuity.

1 Core HT XLPE Cable Straight Through Joint


1.Outer Sheath 2.Inner Sheath 3.Black Mastic 4.Semicon 5.Stress Grading Mastic 6.Tinned
Copper Braid 7.XLPE Insulation 8. Tinned Copper wire Mesh 9.Stress Grading Mastic
10.Stress Control Tube 11.Insulating Tube 12.Ferrule 13.Semi-conductive Tube 14.
Corrosion Protection Tube 15. Metallic Screen 16. S.S.Hose Clips 17. Black Mastic

The design of straight joint fulfills the following functional


requirements.
Electrical Stress control
In a radial field (screened) cable, operating on AC system, the
distribution of voltage along the surface of insulation from the
conductor to screen terminating point is not uniform. This result in
occurrence of a high electrical stress at the point of termination of the
screen resulting in degradation of insulation at this point, eventually
leading to premature breakdown.
Occurrence of high electrical stress over ferrule area is eliminated by
filling stress grading mastic all around the ferrule and over the
exposed conductor.
Insulation Build-up
The insulation build up over the connector is achieved by means of
multiple layers of heat shrinkable tubes possessing high dielectric
strength and thermal stability. The number of insulation tubes are
predesigned to achieve an optimum thickness of insulation. This
precludes detrimental field variables related to jointing skill (such as
under application and eccentricity of build up insulation), hence the
system is by far, skill-independent.
Insulation Screen

Insulation screen over built up insulation is provided by means of a


heat shrinkable semi-conductive tube.

Armour and Screen Continuity


A flexible tinned copper wire mesh provides metallic screening over
each core. The wire mesh supplements the semiconducting screening
tube which is shrunk over built up insulation. In addition to this , a
copper braid, which is equivalent in electrical cross section area, to
the metal screen of each cable core, is provided to carry earth fault
currents. Armour continuity arrangement for XLPE cable is designed
to provide a permanent and low contact resistance bond. This limits
rise in temperature at bonding points even during flow of high earth
currents.
Mechanical Protection
Mechanical protection to the joint is provided by means of a metallic
case. The case has a high "impact resistance-to-weight" ratio.
Environmental Sealing and Corrosion Protection
Corrosion protection to the metal parts (case and armour) is provided
by means of heat shrinkable tubes coated internally with hot melt
adhesive for blocking entry of water into the joint. The tubes are
impact and corrosion resistant.