Professional Documents
Culture Documents
Technical data
nach VDI 3267
General parameters Hydraulic parameters Electrical parameters
Designation: Operating pressure Actuation: Degree of protection for
Directional control valve p [bar] VH solenoid and electrical
Symbol: X = extern: 350 Switching times 3) connection to DIN 40050:
See type key at port P, A, B: Pilotventil [ms]: IP 65
X = intern: 350 te: 50 Electrical connection:
Design:
at port T: ta: 30 See type key
Spool-type valve
X = extern: 350
Type of mounting: Number of switchings/h,
Y = intern: 160
Flange approx.:
Control pressure pSt [bar] 2): 15000 1)
Line connection: 8,5 to 350
1) VSt min 10 bar for symbol 013
Subplate Rated voltage connector input 2)
or symbols 011 and 013 the control
F
Control volume VSt [cm3]: UN [V]: pressure is achieved by the
Line connection: Symbol 019, 020: 8.4 Standard voltages: precharge cartridge valve in P.
any Symbol 008, 009: 4.2 3)
24 DC 230 AC 40...60 Hz he main valve switching time is
T
Weight of valve with: Symbol 013: 4.9 +5%/-10% +5%/-10% dependant on the control oil supply.
1 actuator [kg]: 9.7 Pressure fluid temperature Special voltages on request
2 actuators [kg]: 10.3 Ju max. [°C]:
Power consumption
Weight of subplate: +70
P20 [W]:
G 3/4 [kg]: 9.0 Viscosity range: n [mm2/s]: 31
G 1 [kg]: 9.0 12 to 500
Duty cycle [%]:
Weight of non-return valve Flow Qmax [l/min]: 100
double-throttle [kg]: See characteristic curves
1.7
Ambient temperature range
Ju [°C]:
-20 to +50
Size:
DN 16
7500901.06.04.13 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
1
Directional control valves DN 16
1)
Symbols are shown in operation type: electro-hydraulic
with control type: 17
Connecting plate
Type Cat. No.
G 3/4 P S 16 G 5 001 2 O O 1065186
G1 P S 16 G 6 001 2 O O 1065187
Ordering
The units are designated by their type number. The composition of Flanged valves are provided with O-rings and mounting screws.
this number can be drawn from the type code. The standard ver- Subplate must be ordered separately.
sions are listed in the type survey. When ordering any of the stan-
dard versions, please state type number as well as catalog number
to preclude possible misinterpretations.
Further valve versions can be composed via combination of types -
order numbers on request.
2 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7500901.06.04.13
Directional control valves DN 16
Type key
Directional control valve 4 Symbol:
S 16 ... ... ... G ... 0016 ... ... Symbol Symbol Overlap
No.
1 2 3 4 5 6
020 +
1 Actuation: VH – DC-type solenoid,
pressure-tight, with manual
override 019 1) +
Y – Hydraulic
2 Control type:
008 +
Pilot Control oil- Control oil- Timed
inlet X outlet Y settings
17- S 6 internal external none 009 +
18- S 6 external external none
19- S 6 internal external available
20- S 6 external external available 013 2) -
21- S 6 internal internal none
22- S 6 external internal none
23- S 6 internal internal available For the symbols shown: Solenoid operated valve with control pattern 17
24- S 6 external internal available Locking not possible with hydraulic and direct pneumatic operation.
1)
1)
Y = control oil supply 5 Additional data: O – Standard design
M – mechanical detend of the
pilot valve
R – Pilot cartridge in port P 2)
3 Electrical connection: (main valve)
6 Sealing material: O – Perbunan
00- Operation without
V – Viton
electrical connection
10- PG 11 socket according
to DIN 43650 mounted
on solenoid
11- PG 11 socket according
to DIN 43650 mounted
on solenoid with integrated
rectifier
12- PG 11 socket according
to DIN 43650 mounted Subplate
on solenoid with integrated
rectifier P S 16 G ... 001 ... O O
signal indicator mounted on socket 1 2
13- PG11 socket according
to DIN 43650 mounted 1 Line connection: 5 – G 3/4 (internal thread
on solenoid, signal indicator 6 – G1 to DIN ISO 228/1)
mounted on socket 2 Engineering version: 2
7500901.06.04.13 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
3
Directional control valves DN 16
Ordering example
4/3-way NG 16 directional valve, Directional control valve: 4/3-way NG 16 directional valve, Directional control valve:
pilot operated; AC 230V 50 Hz, Type No.: pilot opersted; DC 24V; Electrical Type No.:
Electrical connection: Connector S 16 VH 17 11 G 008 001 6 O O connection: Connector with S 16 VH 17 10 G 008 001 6 O O
with rectifier on solenoid, Cat. No.: rectifier on solenoid, symbol 008, Cat. No.:
symbol 008, internal control oil 5205599.7234.20500 internal control oil flow, external 5205598.7234.02400
flow, external control oil return, control oil return, with G 3/4"
with G 3/4" subplate. subplate.
Subplate:
Type No.:
P S 16 G 5 001 2 O O
Cat. No.:
1065186
4 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7500901.06.04.13
Directional control valves DN 16
Control modes
Control type: 17
detailed symbol simple symbol
Internal control oil feed:
4/2-
Port “X“ in subplate closed.
Control
Port “p“ in main valve opened.
valve
020
External control oil feed:
Connector for control oil return in “Y“
in subplate. Port “t“ in main valve closed.
4/2-
Control
valve
019
4/3-
Control
valve
008
7500901.06.04.13 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
5
Directional control valves DN 16
Dimensional drawings
Directional valve: See subplate dimensioned drawing for the dimensions of the connection layout.
Interface S 16
DIN 24340 - A 16 / ISO 4401
Tightening torque:
M 15 DIN 912 - 10.9 = 7.6 Nm
M 16 DIN 912 - 10.9 = 13 Nm
M 10 DIN 912 - 10.9 = 62 Nm
6 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7500901.06.04.13
Directional control valves DN 16
Dimensional drawings
Switching times set
by double throttle
non-return valve
MU 2 S6 ...
Control type
19, 20, 23, 24, 29
7500901.06.04.13 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7
Directional control valves DN 16
Dimensional drawings
Subplate with interface according to DIN 24 340-A 16 and ISO 4401-AD-07-4-A
Aperture for
connection in
control panel
8 depth
Section A-B
Cat. No. a b c
10 651 86 G 3/4 ø 41 16.5
10 651 81 G1 ø 47 18.5
8 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7500901.06.04.13
Directional control valves DN 16
Characteristic curves
7500901.06.04.13 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
9
Directional control valves DN 16
Pilot valve
S 6 ...
Main valve
S 16 ...
Subplate
Electrical connection
11 and 13
Pilot valve
Double throttle
non-return valve MU
2 S6 ... Throttle 2
Throttle 1
Main valve
10 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7500901.06.04.13
Directional control valves DN 16
10 1)
Pilot valve complete
1)
Pilot valve complete For 2-position valves with spring = 1 off or S6VH10G0200011OV 5203541.7234.024
return 1 off S6SH11G0200011OV 5204082.7234.209
For 2-position valves with = 1 off or S6VH10G0190011MV 5203942.7234.024
ocking 1 off S6VH11G0190011MV 5204089.7234.205
For 3-position valves with spring = 1 off or S6VH10G0090011OV 5203940.7234.024
return to central 0 position 1 off S6SH11G0090011OV 5204093.7234.203
7500901.06.04.13 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
11
Directional control valves DN 16
12 Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
7500901.06.04.13