DRAWING No.

560-000-ST-I-029

IM007
IM007 IM012 IM005
IM012 IM005
IM009

POR CANERIAS
IM010 IM011

IM012 POR CANERIAS IM012


IM011 IM003

FLUSHING FLUSHING

TIPO_A TIPO_B

SERVICIO_DE_PULPAS_ SERVICIOS LIMPIOS Y CORROSIVOS


CONEX._FLANGE_SIN_CAPILAR CONEX._FLANGE_SIN CAPILAR

IM015 1 2" ANSI CLASS 150 SS316 Flange Slip-On RF Class 150. ASME B16.5 Roscado
IM014 1 1/2"F-NPT x 1/2" M-NPT 2000 Psi-g @ 300 °C SS316 Conector Roscado Hembra NPT a Macho NPT
IM012 1 1/4"OD x 1/4" NPT 2000 Psi-g @ 300 °C SS316 Conetor OD a NPT Macho Con Kit Ferula
IM011 1 4 1/2" OD 260 Psi-g @ 530 °C PTFE Packing ASME B16.21 Para Flange Roscado con Rosca para Tuberias de 1"
IM010 1 1" ANSI CLASS 150 SS316 Flange Slip-On RF Class 150. ASME B16.5 Roscado
IM009 4 5/8" x 3" 300 Psi-g SS Pernos tipo Machine, ASTM A193 GR. B7, Con Tuerca Hexagonal y Cabeza Semi Terminada (HD)
IM007 1 1/4"OD 2000 Psi-g @ 300 °C SS316 Tubing SMLS con Espesor de Pared 0.035"
IM005 1 1/2" NPT 2000 Psi-g @ 300 °C SS316 Valvula de Bola Hembra Roscada NPT, Con Asiento y Sellos de PTFE Reforzado
IM003 1 1/2" NPT 2000 Psi-g @ 300 °C SS316 Niple Roscado Macho Con Tuerca Hexagonal Intermedia
SCHEDULE
PART MATERIAL
QUANTITY SIZE OR DESCRIPTION
No. RATING
DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
QUALITY CONTROL

DISCIPLINE MANAGER NAME SIGN


DOCUMENT CONTROL

THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN NAME SIGN & STAMP

REFERENCES REVISIONS REVISIONS SCALE: PROJECT


DWG. NO. TITLE NO. D ESC RIPTI ON BY CHECK APPROVED DATE NO. D ESC RIPTI ON BY CHECK APPROVED DATE
NOTICE
SHEET SIZE

A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL CHANGES HERE TO SHALL BE
PERFORMED USING CADD ONLY.
THIS DRAWING IS THE PROPERTY OF AND EMBODIES PROPRIETARY INFORMATION
BELONGING TO AKER SOLUTIONS AND MUST BE RETURNED IMMEDIATELY UPON
DRAWN BY: EV DATE:
AREA
000 - GENERAL AREA C-560 REVISION
REQUEST. IT MUST NOT BE COPIED IN WHOLE OR IN PART, NOR THE INFORMATION
TITLE CAD NO.
MM INSTALLATION DETAILS
SHOWN THERE ON DISCLOSED TO THIRD PARTIES EXCEPT WI TH THE WRITTEN
PERMISSION. CHECKED BY: DATE:

APPROVED BY: MM DATE:


1
AUTHORIZED BY:
PROCESS DETAILS - PRESSURE DWG. NO.
DATE:
MINERA CHINALCO PERU S.A. PRESSURE GAGE - CORROSIVE SERVICES
1 ISSUED FOR CONSTRUCTION EV MM MM 10/4/2011 MCP APPROVED: DATE:
560-000-ST-I-029
User: $USERNAME$ $DATE$ $TIME$ $FILE$