You are on page 1of 11

Punching Shear Strength Design of RC Slab According ACI318M-08

Project :- Project Designed by:-


Building :- Building Checked by:-
Element:- Element Date:- 26-Apr-18
Location:- Location

General Input :-
Flat Slab Input
Slab thk t 260 mm fy 420 N/mm2
cover 30 mm fc' 28 N/mm2
d 220 mm fyt 420 N/mm2
Normal weight concrete λ = 1
Column Dimensions
c1 Depth 500 mm
c2 Width 200 mm
Position Interior Column Case B

ᵦ 2.50 ACI 11.11.2.1.a


αs 40 ACI 11.11.2.1.b
Punching Shear Input
Vu 455 KN
Mu1 11 KN.m
Mu2 2 KN.m

a-Calculation of RC punching shear resistance without shear reinforcement (φVn = φVc)


b1 720 mm b2 420 mm bo substracted 0
bo 2280 mm ACI 11.11.1.2
ϕ_𝑠ℎ� 0.75 ACI 9.3.2.3 & ACI 9.3.4.a
𝑎� 0.17(1+2/𝛽)�√
( 〖𝑓′〗 _� ) = 1.619 N/mm2 ACI 11.11.2.1.a

Vc = min. of 0.083 ((�_� 𝑑)/𝑏_𝑜 = 2.574 N/mm2 ACI 11.11.2.1.b


+2) �√( 〖𝑓′〗 _� )
0.33�√
= 1.746 N/mm2 ACI 11.11.2.1.c
( 〖𝑓′〗 _� )
ϕ𝑉_ = 1.214 N/mm2

b-Calculation of unbalanced moment transferred by eccentricity of shear
�_(𝑓_1 )=1/(1+(2⁄3) �_(𝑓_2 )=1/(1+(2⁄3)
√(𝑏_1⁄𝑏_2 )) = 0.534 √(𝑏_2⁄𝑏_1 )) = 0.663 ACI 13.5.3.2

�_(𝑣_1 ) = 0.466 �_(𝑣_2 ) = 0.337 ACI 11.11.7.1


=(1− �_(𝑓_1)) =(1− �_(𝑓_2))
𝐽⁄�_ 1.081E+08 𝐽⁄�_ 8.301E+07 PCA NOTES ON ACI318-08, Fig. 16-13
1 2
c-Calculation of total punching stress
ϕ𝑣_(𝑛 𝑚𝑎𝑥) = = 1.984 N/mm2 ACI 11.11.5.2.a &b
0.5ϕ𝜆√( 〖𝑓′〗 _� )
𝑣_� = 𝑉_�/(�_� 𝑑) + = 0.963 N/mm2 < Φvn max
〖� _(�_1 ) � 〗 _�1/
(�⁄�_1 ) + 〖� _(�_2 )
� 〗 _�2/(�⁄�_2 )
Slab Punching Design, ACI318-08 Page 1 of 11 M.A.S
Punching Shear Strength Design of RC Slab According ACI318M-08
Project :- Project Designed by:-
Building :- Building Checked by:-
Element:- Element Date:- 26-Apr-18
𝑣_� =Location:- Location
𝑉_�/(�_� 𝑑) +
〖� _(�_1 ) � 〗 _�1/
(�⁄�_1 ) + 〖� _(�_2 ) < ΦVc, No need for Shear RFT.
� 〗 _�2/(�⁄�_2 )

Slab Punching Design, ACI318-08 Page 2 of 11 M.A.S


Punching Shear Strength Design of RC Slab According ACI318M-08
Project :- Project Designed by:-
Building :- Building Checked by:-
Element:- Element Date:- 26-Apr-18
Location:- Location

d-Calculation of Shear RFT.


vs = 0.000 N/mm2 ,ACI 11.11.7.2.b 𝑣_(𝑠 𝑚𝑎𝑥) = = 3.492 N/mm2 ,ACI 11.4.7.9
0.66𝜆√( 〖𝑓′〗 _� )
Sstirrup 100 mm OK Smax = 110.0 mm, ACI 11.11.3.3
Av 0.0 mm2 Stirrup Dia. 10 mm
nstirrup branch 6 Total number of branches distributed on all sides No. sides =4
Av/stirrup leg 0.0 mm2/side/leg
Av bar act 79.0 mm2
a distance 328 mm Distance that stirrups shall be extended to it, from the column face in each side

Slab Punching Design, ACI318-08 Page 3 of 11 M.A.S


Punching Shear Strength Design of RC Slab According ACI318M-08
Project :- Project Designed by:-
Building :- Building Checked by:-
Element:- Element Date:- 26-Apr-18
Location:- Location

Slab Punching Design, ACI318-08 Page 4 of 11 M.A.S


rev 1.1

26-Apr-18

mm

PCA NOTES ON ACI318-08, Fig. 16-13

Φvn max

Slab Punching Design, ACI318-08 Page 5 of 11 M.A.S


rev 1.1

26-Apr-18

ΦVc, No need for Shear RFT.

Slab Punching Design, ACI318-08 Page 6 of 11 M.A.S


rev 1.1

26-Apr-18

N/mm2 ,ACI 11.4.7.9


mm, ACI 11.11.3.3

ce that stirrups shall be extended to it, from the column face in each side

Slab Punching Design, ACI318-08 Page 7 of 11 M.A.S


rev 1.1

26-Apr-18

Slab Punching Design, ACI318-08 Page 8 of 11 M.A.S


DIA (mm) Area (mm2) Case
6 29 E For Seismic Cases
8 51 G For Non-seismic Cases
10 79
12 114 Yes
14 154 No
16 201
18 255 External_Calc.
20 314 No.
22 380
25 491
32 804
rev1.0
Date: 6-Nov-14
1- correcting the calculation of cell E30, it was a constant value in pervious rev.
it is now calculating the value of 0.17*(1+2/ᵦ)*SQRT(fc) correctly.
2- All cells equations now are visible even if the sheet is password protected.
3- Modifiying the shear rft. Calculations.
4- adding vs max= Φshear*0.66*SQRT(fc) in cell i42 and compare it with vs calculated, as noted by "Eng. Mohamed elsaw