You are on page 1of 31

Kuhnke Technical Data

The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs
and any page number shown is relevant to the original document. The PDF sheets here may
have been combined to provide technical information about the specific product(s) you have
selected.

Hard copy product catalogues, and CDROMs have been published describing Kuhnke
Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of
current publications is available on this web site or from our sales offices. Some may be
available for download, but as substantially larger files.

Contact Details
Kuhnke sales and service in North America

Ellis/Kuhnke Controls
132 Lewis Street
Unit A-2, Eatontown
NJ 07724
USA

T: (800) 221 0714


T: (732) 291 3334
F: (732) 291 8154

Important Note

The information shown in these documents is for guidance only. No liability is accepted for any
errors or omissions. The designer or user is solely responsible for the safe and proper
application of the parts, assemblies or equipment described.
Hochleistungs-
Hubmagnete RM, URM
Heavy Duty Solenoids
Series RM, URM
Hochleistungs-Hubmagnete Heavy Duty Linear Solenoids
Geschlossene Bauweise Fully Encapsulated Design
Technische Beschreibung/ Technical description/
Vorzugstypen Preferred types

Typ RM einfachwirkend Series RM single acting,


Typ URM umkehrwirkend series URM two directional

Die Typen RM und URM sind Hoch- Series RM and URM heavy duty solenoids
leistungshubmagnete in geschlossener are fully enclosed. These specifications
Bauweise. Diese Ausführungen sind be- are designed for maximum durability, this
vorzugt dort einzusetzen, wo höchste being ensured by service-free armature
Lebensdauer gefordert wird. Durch eine bearing on both sides. These solenoids
beidseitige wartungsfreie Ankerlagerung can be mounted at any angle.
wird diese Forderung erfüllt. Sie können
in beliebiger Einbaulage montiert wer- The coil voltage is usually designed for
den. DC (AC on request).

Die Spulenspannung wird in der Regel in Apart from the standard models we offer
Gleichspannung ausgeführt (Wechsel- you a multitude of custom-made linear
spannung auf Anfrage). solenoids (see examples on pages
37-39).
Neben den Standardtypen steht eine
Vielzahl von Sonderhubmagneten zur
Verfügung (siehe Beispiele Seite 37-39).

O-F
-HRR D
W %E
M070 C100
R 4VD
2

O-F
-HRO D
W E
M070 C100%
R 4VD
2

R-F
-ORO D
W E
M070 C100%
R 4VD
-F 2
B OO
W-O ED
M070 C100%
R 4VD
2

Magnet Hauptkatalog 104 Main catalogue


Hochleistungs-Hubmagnete Heavy Duty Linear Solenoids
Geschlossene Bauweise Fully Encapsulated Design
Technische Beschreibung/ Technical description/
Vorzugstypen Preferred types

RM 20 –F– 24 V DC 100 % ED
RM 32 –F– 24 V DC 100 % ED
Vorzugstypen RM 40 –F– 24 V DC 100 % ED Preferred types
Hochleistungs-Hubmagnete RM 050 W*-OBOO –F– 24 V DC 100 % ED Heavy duty linear solenoids
RM 070 W*-OBOO –F– 24 V DC 100 % ED
RM 100 W*-OBOO –F– 24 V DC 100 % ED
* W = waagerechte Kennlinie * W = horizontal characteristics

Die obenstehenden Hochleistungs-Hub- The heavy duty solenoids listed in the


magnete Typ RM werden als Vorzugs- table are preferred types and are always
typen lagermäßig geführt, damit Sie ei- in stock, enabling you to have them
nen schnellen und preisgünstigen Zugriff delivered quickly and at a competitive
für Ihre Versuche haben. price for your tests.

Die Vorzugstypen sind in kleinen Stück- The preferred types can be delivered
zahlen (Zwischenverkauf vorbehalten) within a week (in small numbers) condi-
innerhalb einer Woche lieferbar. tional to no resale. They are designed to
Sie sind ausgelegt für 24 V DC und operate at 24 V DC and 100 % ED.
100 % ED.

Bei Verwendung einer verstellbaren If an adjustable voltage source is used,


Spannungsquelle kann der Magnet über the solenoid can be operated at a higher
die Nennspannung hinaus betrieben wer- voltage than that given in the rating, in
den, um die für die Betätigung erforderli- order to obtain the required power.
che Kraft zu erreichen.

Beachten Sie hierbei bitte, daß bei län- However, these solenoids are subject to
gerem Betrieb an erhöhter Betriebsspan- overheating during long term use with in-
nung diese Magnete überhitzt werden, creased voltage, unless sufficiently long
wenn nicht ausreichende Pausen bei ei- intervals and a maximal operating time
ner max. Spieldauer (Einschaltzeit + Aus- (switch on time + switch off time) of 5
schaltzeit) von 5 Minuten eingehalten min are observed.
werden. Zu Ihrer Information hier der ma-
thematische Zusammenhang:

UN UN
U= U=
2.162 ED 2.162 ED
100 100
U = Betriebsspannung (Anwender) U = applied operating voltage
UN = Nennspannung – bzw. Standard- UN = rated voltage or standard voltage
spannung 24 V DC 24 V DC
ED = relative Einschaltdauer (%) ED = relative duty cycle (%)

Zur Ermittlung der für Ihren Anwendungs- In order to calculate the power required
fall erforderlichen Kraft ist der Spulen- in your case, the coil current has to be
strom zu messen. Die genaue Festlegung measured. The exact determination of
der Spule erfolgt in unserer Entwicklungs- the duty cycle is made in our develop-
abteilung: Geben Sie uns bitte hierzu ment laboratories. We would therefore
den Magnetspulenstrom an, unter Berück- ask you to supply us with the value for
sichtigung der geforderten max. Ein- coil current taking into consideration the
schaltdauer. max. duty cycle requested.

Magnet Hauptkatalog 105 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 13 RM 13

Stoßende und ziehende Ausführung Thrust and pull type

Bestellformel RM 13 –F– 24 V DC 100 % ED Order specifications


Hubmagnet RM Linear solenoid
Bauart 13 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Nennspannung (Standardspannung)1) 24 Nominal voltage (standard voltage)1)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Die Magnete sind auf Anfrage bis 60 V DC Other voltages are available on request up to
lieferbar 60 V DC

Gewicht: Weight:
Magnet: ca. 25 g Complete
solenoid: appr. 25 g
Anker: ca. 4 g Armature: appr. 4 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm Flying leads: 10 cm
Isolierstoffklasse: B (Tgrenz = 130 °C) Insulation class: B (max. permissible
temperature = 130 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 B 75 according to: VDE 0110 B 75
Prüfspannung: 600 V (eff) Test voltage: 600 V (eff)

In Sonderausführung mit eingebauter Return spring optional.


Rückholfeder lieferbar.

≤5
Ø1,5

2,8

Ø2
Ø13
M6
Ø5
2

Maße im bestromten Zustand Dimensions given with armature in fully


3 ≤34 6+0,5
home position
+1
–––––––> 8 50 –––––––>
Hubrichtung 9 Direction of stroke

Zul. rel. Einschaltdauer (ED)2) % 100 50 25 5 % Perm. duty cycle (ED)2)


Nennaufnahme P 20 W 2,9 5,4 10,1 43,3 W Nominal coil power P 20
2) Bei Montage auf eine Kühlfläche ist eine höhere 2) If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is
permissible (please ask for advice)

10 %ED
8
5
F [N]

2 5 Force vs. Stroke diagramm F = f (s)


Kraft-Weg-Diagramm F = f (s)
1
25

0,5
50
Force measured when operating in horizontal
Kraft bei waagerechter Bewegungsrichtung und position, at 90 % rated voltage and with winding at
bei 90 % Nennspannung und betriebswarmer 0,2 operating temperature
100
Wicklung
stroke s = 0 corresponds to armature in
0,1
Hub s = 0 entspricht dem angezogenen, 0 1 2 3 4 5 6 fully home position
bestromten Zustand S [mm]

Magnet Hauptkatalog 106 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 20 RM 20

Stoßende und ziehende Ausführung Thrust and pull type

Bestellformel RM 20 –F– 24 V DC 100 % ED Order specifications


Hubmagnet RM Linear solenoid
Bauart 20 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Steckhülsenanschluß 2,8 DIN 46247 M Terminal box (2.8 DIN 46247)
Nennspannung (Standardspannung)1) 24 Nominal voltage (standard voltage)1)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Die Magnete sind auf Anfrage bis 60 V DC Other voltages are available on request up to
lieferbar 60 V DC

Gewicht: Weight:
Magnet: ca. 60 g Complete
solenoid: appr. 60 g
Anker: ca. 12 g Armature: appr. 12 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm Flying leads: 10 cm
Isolierstoffklasse: B (Tgrenz = 130 °C) Insulation class: B (max. permissible
temperature = 130 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 300 according to: VDE 0110 C 300
Prüfspannung: 800 V (eff) Test voltage: 800 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.
M3

M3

SW14
M6

Maße im bestromten Zustand Dimensions given with armature in fully


8 2 8 Ø12 home position
–––––––> 7 28 8 12 Ø16 –––––––>
Hubrichtung 66,5 Ø20 Direction of stroke

Zul. rel. Einschaltdauer (ED)2) % 100 45 25 15 5 % Perm. duty cycle (ED)2)


Nennaufnahme P 20 W 3,9 8 13,5 21 59 W Nominal coil power P 20
Anzugszeit (ED) ms 11 5 ms Actuation time (ED)
2) 2)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is
permissible (please ask for advice)

100 %ED

50
F [N]

20 Force vs. Stroke diagramm F = f (s)


Kraft-Weg-Diagramm F = f (s)
10 5

5 15
25 Force measured when operating in horizontal
Kraft bei waagerechter Bewegungsrichtung und position, at 90 % rated voltage and with winding at
45
bei 90 % Nennspannung und betriebswarmer 2 operating temperature
Wicklung 100
stroke s = 0 corresponds to armature in
1
Hub s = 0 entspricht dem angezogenen, 0 1 2 3 fully home position
bestromten Zustand S [mm]

Magnet Hauptkatalog 107 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 26 RM 26

Stoßende und ziehende Ausführung Thrust and pull type

Bestellformel RM 26 –F– 24 V DC 100 % ED Order specifications


Hubmagnet RM Linear solenoid
Bauart 26 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Nennspannung (Standardspannung)1) 24 Nominal voltage (standard voltage)1)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) Die Magnete sind auf Anfrage bis 60 V DC 1) Other voltages are available on request up to
lieferbar 60 V DC

Gewicht: Weight:
Magnet: ca. 117 g Complete
solenoid: appr. 117 g
Anker: ca. 24 g Armature: appr. 24 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm Flying leads: 10 cm
Isolierstoffklasse: B (Tgrenz = 130 °C) Insulation class: B (max. permissible
temperature = 130 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 B 150 according to: VDE 0110 B 150
Prüfspannung: 800 V (eff) Test voltage: 800 V (eff)

Wartunsfreie Ankerlagerung (DU-Lager) Service-free DU armature bearing for


für höchste Lebensdauer. maximum durability.
Waagerechte Kennlinie auf Anfrage. Linear force vs. stroke output optional.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.
M3

M3

SW17
M10

Maße im bestromten Zustand Dimensions given with armature in fully


8 2 8 Ø17
home position
–––––––> 7,5 30 10 13 Ø19 –––––––>
Hubrichtung 72 Ø26 Direction of stroke

Zul. rel. Einschaltdauer (ED)2) % 100 40 25 15 5 % Perm. duty cycle (ED)2)


Nennaufnahme P 20 W 5,5 12,2 18,9 35,3 84 W Nominal coil power P 20
2) Bei Montage auf eine Kühlfläche ist eine höhere 2) If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is
permissible (please ask for advice)

100 %ED

50
F [N]

20
Kraft-Weg-Diagramm F = f (s) 5
Force vs. Stroke diagramm F = f (s)
10
15
25
5
40
3
Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 2 100 position, at 90 % rated voltage and with winding at
Wicklung operating temperature
1
Hub s = 0 entspricht dem angezogenen, 0 1 2 3 4 stroke s = 0 corresponds to armature in
bestromten Zustand S [mm] fully home position

Magnet Hauptkatalog 108 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 32 RM 32

Stoßende und ziehende Ausführung Thrust and pull type

Bestellformel RM 32 –F– 24 V DC 100 % ED Order specifications


Hubmagnet RM Linear solenoid
Bauart 32 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Steckhülsenanschluß A 2,8 DIN 46247 M Terminal box 2.8 DIN 46247
Nennspannung (Standardspannung)1) 24 Nominal voltage (standard voltage)1)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Die Magnete sind auf Anfrage bis 60 V DC Other voltages are available on request up to
lieferbar 60 V DC

Gewicht: Weight:
Magnet: ca. 235 g Complete
solenoid: appr. 235 g
Anker: ca. 40 g Armature: appr. 40 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm F Flying leads: 10 cm
32- ED
Isolierstoffklasse: B (Tgrenz = 130 °C) RM 100% Insulation class: B (max. permissible
DC
24V temperature = 130 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 B 150 according to: VDE 0110 B 150
Prüfspannung: 800 V (eff) Test voltage: 800 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Waagerechte Kennlinie auf Anfrage. Linear force vs. stroke output optional.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.
M3
M4
M4

Ø18

Maße im bestromten Zustand Dimensions given with armature in fully


10 4 2 10 Ø18 home position
–––––––> 11 45 24 24 –––––––>
Hubrichtung 94 Ø32 Direction of stroke

Zul. rel. Einschaltdauer (ED)2) % 100 70 45 25 15 5 % Perm. duty cycle (ED)2)


Nennaufnahme P 20 W 65 10 16 24 48 122 W Nominal coil power P 20
Anzugszeit (ED) ms 29 11 ms Actuation time (ED)
2) 2)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is
permissible (please ask for advice)

100 %ED

50
F [N]

5
20 10
Kraft-Weg-Diagramm F = f (s) 15 Force vs. Stroke diagramm F = f (s)
10 25

50
5

Kraft bei waagerechter Bewegungsrichtung und 100


Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 2 position, at 90 % rated voltage and with winding at
Wicklung operating temperature
1
Hub s = 0 entspricht dem angezogenen, 0 2 4 6 8 stroke s = 0 corresponds to armature in
bestromten Zustand S [mm] fully home position

Magnet Hauptkatalog 109 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 40 RM 40

Stoßende und ziehende Ausführung Thrust and pull type

Bestellformel RM 40 –F– 24 V DC 100 % ED Order specifications


Hubmagnet RM Linear solenoid series
Bauart 40 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Steckhülsenanschluß (6,3 DIN 46247) N Terminal box (6.3 DIN 46247)
Nennspannung (Standardspannung)1) 24 Nominal voltage (standard voltage)1)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Die Magnete sind auf Anfrage bis 230 V DC Other voltages are available on request up to
lieferbar 230 V DC

Gewicht: Weight:
Magnet: ca. 380 g Complete
solenoid: appr. 380 g
Anker: ca. 60 g Armature: appr. 60 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm 40
-F D
E
Flying leads: 10 cm
RM 0 %
Isolierstoffklasse: B (Tgrenz = 130 °C) C1
0 Insulation class: B (max. permissible
VD
24 temperature = 130 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 300 according to: VDE 0110 C 300
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Waagerechte Kennlinie auf Anfrage. Linear force vs. stroke output optional.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer (ED)2) % 100 75 45 25 15 5 % Perm. duty cycle (ED)2)


Nennaufnahme P 20 W 11 13,5 21 34 54 165 W Nominal coil power P 20
Anzugszeit (ED) ms 36 11 ms Actuation time (ED)
2) 2)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is
permissible (please ask for advice)

100 %ED

50
F [N]

5
15
20
25
Kraft-Weg-Diagramm F = f (s) Force vs. Stroke diagramm F = f (s)
10 45
75
100
5

Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 2 position, at 90 % rated voltage and with winding at
Wicklung operating temperature
1
Hub s = 0 entspricht dem angezogenen, 0 2 4 6 8 stroke s = 0 corresponds to armature in
bestromten Zustand S [mm] fully home position

Magnet Hauptkatalog 110 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 40 RM 40

Stoßende und ziehende Ausführung Thrust and pull type

Ø22
M5

M5

M4
Ø20
12 5 2 12 Ø22
16 45 32 Ø30
110 Ø40

Maße im bestromten Zustand Dimensions given with armature


in fully home position
–––––––> –––––––>
Hubrichtung Direction of stroke

Magnet Hauptkatalog 111 Main catalogue


Magnet Hauptkatalog 112 Main catalogue
Hochleistungs-Hubmagnete Heavy Duty Linear Solenoids
RM 050 ... RM 100 RM 050 ... RM 100

Bestellformel RM 070 – W – O R O R – N – 24 V DC 100 % ED Order specifications


Hubmagnet RM Linear solenoid series
Bauart ø mm 050 Design type ø mm
060
070
080
090
100
bis 160 mm auf Anfrage 1601) 160 mm optional
Waagerechte Kraft-Weg-Kennlinie W Horizontal frontal force vs. stroke output
Ausführung2) Description2)
Hubbegrenzung ohne O Stroke limit without
mit H with
Stößel rechts3) R Plunger right hand side3)
beidseitig B both sides
Flansch ohne O Flange without
rechts3) R right hand side3)
links4) L left hand side4)
Faltenbalg ohne O Gaiter without
rechts3) R right hand side3)
links4) L left hand side4)
beidseitig5) B both sides5)
Anschlußart Litze (Standardlänge 20 cm) F Coil terminals Flying leads
(20 cm standard length)
Gerätestecker6) N plug-in socket connection6)
Nennspannung 24 V DC 24 Operating voltage 24 V DC
205 V DC (an 230 V AC 205 205 V DC (connected to
nach SI-Gleichrichter- 230 V AC with SI- bridge
brücke) rectifier)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Bis 160 mm auf Anfrage Up to 160 mm optional
2) Siehe unten 2) See below
3) Entgegengesetzt zur elektr. Anschlußseite 3) Opposite to electrical connection
4) An der elektr. Anschlußseite 4) Same side as electrical connection
5) Nur mit Hubbegrenzung lieferbar 5) Available only with stroke limit
6) Für Steckhülse 6,3 DIN 46247 und 6) For plug-in socket 6.3 DIN 46247 and plug

Gerätesteckdose Z 801 und Z 811 Z 801 and Z 811


Zubehör siehe Seite 130-131 Accessories see pages 130-131
ca.12

200 +15

Anschlußarten Coil terminals


ca.12

Beispiele für Ausführungen: N F Examples of design types:


Ohne Anschlagdeckel; without end stop
keine Hubbegrenzung im without stoke limit in the open position
offenen Zustand

–OBOO– –OBLO– –OBOR– –ORRO– –OROR–

–HBOO– –HBLO– –HBOL– –HRRO– –HROR–

Magnet Hauptkatalog 113 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 050 RM 050

Hochleistungs-Hubmagnet RM 050 Heavy duty linear solenoid RM 050

Gewicht: Weight:
Magnet: ca. 610 g Complete
solenoid: appr. 610 g
Anker: ca. 200 g Armature: appr. 200 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 20 cm Flying leads: 20 cm
Isolierstoffklasse: F (Tgrenz = 155 °C) Insulation class: F (max. permissible
temperature = 155 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 450 according to: VDE 0110 C 450
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Bei Ausführung mit Standard-Hubbe- Stroke of version with standard stroke
grenzung Hub 10 mm. limiter: 10 mm.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer (ED)1) % 100 60 35 25 15 5 % Perm. duty Cycle (ED)1)


Nennaufnahme P 20 W 20 30 55 70 115 300 W Nominal coil power P 20
Anzugszeit (ED) ms 40 15 ms Actuation time (ED)
1) 1)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface the duty cycle can be extended (please
ask for advice)

1000 %ED

500

200
Kraft-Weg-Diagramm F = f (s) Force vs. Stroke diagramm F = f (s)
100 5
W = Waagerechte Kennlinie 15 W = horizontal characteristic
50 25
F [N]

35
Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
60
bei 90 % Nennspannung und betriebswarmer 20 position, at 90 % rated voltage and winding at
Wicklung operating temperature
100
10
Hub s = 0 entspricht dem angezogenen, bestromten 0 2 4 6 8 10 stroke s = 0 corresponds to armature in fully home
Zustand S [mm] position

Magnet Hauptkatalog 114 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 050 RM 050

ohne Anschlagdeckel without end stop

M5 Ø34
16
32
5
5

57
50

50

135
5

17
5

Direction of stroke
41
36
16
Hubrichtung

M5
Ø30
Ø4,8
M4
Ø30
Ø50
Ø40

30

42
50
19

mit Anschlagdeckel with end stop

M5 Ø34
16
32
5

Direction of stroke
5

72
65

65
Hubrichtung

32
10
5

7
28
16

M5 Ø34
Ø4,8

Ø30
M4
Ø30
Ø50
Ø40

30

42
50
19

Magnet Hauptkatalog 115 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 060 RM 060

Hochleistungs-Hubmagnet RM 060 Heavy duty linear solenoid RM 060

Gewicht: Weight:
Magnet: ca. 1300 g Complete
solenoid: appr. 1300 g
Anker: ca. 250 g Armature: appr. 250 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 20 cm Flying leads: 20 cm
Isolierstoffklasse: F (Tgrenz = 155 °C) Insulation class: F (max. permissible
temperature = 155 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 450 according to: VDE 0110 C 450
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Bei Ausführung mit Standard-Hubbe- Stroke of version with standard stroke
grenzung Hub 12 mm. limiter: 12 mm.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer (ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)


Nennaufnahme P 20 W 25 60 98 150 381 W Nominal coil power P 20
Anzugszeit (ED) ms 45 17 ms Actuation time (ED)
1) 1)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface the duty cycle can be extended (please
ask for advice)

1000 %ED

500

200
Kraft-Weg-Diagramm F = f (s) 5 Force vs. Stroke diagramm F = f (s)
100
15
W = Waagerechte Kennlinie W = horizontal characteristic
50 25
40
F [N]

Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 20 100 position, at 90 % rated voltage and winding at
Wicklung operating temperature
10
Hub s = 0 entspricht dem angezogenen, bestromten 0 5 10 12 15 stroke s = 0 corresponds to armature in fully home
Zustand S [mm] position

Magnet Hauptkatalog 116 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 060 RM 060

ohne Anschlagdeckel without end stop

M6
M6 Ø36
18
41
5
7

152
72
64
65
7

17
5

Direction of stroke
37

34
29
18
Hubrichtung

M6 Ø36
Ø35
Ø5,8
M5
Ø35
Ø60
Ø45

30

54
67
19

mit Anschlagdeckel with end stop

M6
M6 Ø36
18
41

Direction of stroke
5
7
Hubrichtung

89
82

81
34
10
5

8
29
18

M6 Ø36
Ø35
Ø5,8
M5
Ø35
Ø60
Ø45

30

54
67
19

Magnet Hauptkatalog 117 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 070 RM 070

Hochleistungs-Hubmagnet RM 070 Heavy duty linear solenoid RM 070

Gewicht: Weight:
Magnet: ca. 2000 g Complete
solenoid: appr. 2000 g
Anker: ca. 400 g Armature: appr. 400 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm Flying leads: 10 cm
Isolierstoffklasse: F (Tgrenz = 155 °C) Insulation class: F (max. permissible
temperature = 155 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 450 according to: VDE 0110 C 450
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Bei Ausführung mit Standard-Hubbe- Stroke of version with standard stroke
grenzung Hub 15 mm. limiter: 15 mm.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer (ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)


Nennaufnahme P 20 W 31 78 121 198 472 W Nominal coil power P 20
Anzugszeit (ED) ms 54 25 ms Actuation time (ED)
1) 1)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface the duty cycle can be extended (please
ask for advice)

1000 %ED

500

200
5
Kraft-Weg-Diagramm F = f (s) Force vs. Stroke diagramm F = f (s)
100 15
W = Waagerechte Kennlinie 25 W = horizontal characteristic
50
40
F [N]

Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 20 position, at 90 % rated voltage and winding at
Wicklung 100 operating temperature
10
Hub s = 0 entspricht dem angezogenen, bestromten 0 5 10 15 20 stroke s = 0 corresponds to armature in fully home
Zustand S [mm] position

Magnet Hauptkatalog 118 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 070 RM 070

ohne Anschlagdeckel without end stop

M8
Ø43
20
49
5
8

177
84
74
75
8

20

39 10
543

34

Direction of stroke
20

M8 Ø43
Hubrichtung

Ø38
M5

Ø7
Ø38
Ø70
Ø52

30

62
80
19

mit Anschlagdeckel with end stop

M8 Ø43
20
49
5

Direction of stroke
8
Hubrichtung

103
94

93
39
10

10
534
20

M8 Ø43
Ø38
M5

Ø7
Ø38
Ø70
Ø52

30

62
80
19

Magnet Hauptkatalog 119 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 080 RM 080

Hochleistungs-Hubmagnet RM 080 Heavy duty linear solenoid RM 080

Gewicht: Weight:
Magnet: ca. 2900 g Complete
solenoid: appr. 2900 g
Anker: ca. 500 g Armature: appr. 500 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 20 cm Flying leads: 20 cm
Isolierstoffklasse: F (Tgrenz = 155 °C) Insulation class: F (max. permissible
temperature = 155 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 450 according to: VDE 0110 C 450
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Bei Ausführung mit Standard-Hubbe- Stroke of version with standard stroke
grenzung Hub 20 mm. limiter: 20 mm.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer ED)1) % 100 45 25 15 5 % Perm. duty Cycle (ED)1)


Nennaufnahme P 20 W 37 94 149 226 685 W Nominal coil power P 20
Anzugszeit (ED) ms 75 34 ms Actuation time (ED)
1) 1)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface the duty cycle can be extended (please
ask for advice)

1000 %ED

500

200 5
Kraft-Weg-Diagramm F = f (s) Force vs. Stroke diagramm F = f (s)
100 15
W = Waagerechte Kennlinie 25 W = horizontal characteristic
45
50
100
F [N]

Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 20 position, at 90 % rated voltage and winding at
Wicklung operating temperature
10
Hub s = 0 entspricht dem angezogenen, bestromten 0 5 10 15 20 25 stroke s = 0 corresponds to armature in fully home
Zustand S [mm] position

Magnet Hauptkatalog 120 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 080 RM 080

ohne Anschlagdeckel without end stop

M10
Ø50
30
65
5
9,5

216
85

84

96
23
5

12
9,5

50
45

Direction of stroke
30

M10
M10 Ø50
Hubrichtung

Ø45
Ø9,5
M5
Ø45
Ø80
Ø62

30

90
72
19

mit Anschlagdeckel with end stop

M10 Ø50
30
65
5

Direction of stroke
9,5

241
Hubrichtung

109
110

121
48
25
5

12
10

50
45
30

M10
Ø45 M10 Ø50
Ø9,5
M5
Ø45
Ø80
Ø62

30

90
72
19

Magnet Hauptkatalog 121 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 090 RM 090

Hochleistungs-Hubmagnet RM 090 Heavy duty linear solenoid RM 090

Gewicht: Weight:
Magnet: ca. 4500 g Complete
solenoid: appr. 4500 g
Anker: ca. 800 g Armature: appr. 800 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 20 cm Flying leads: 20 cm
Isolierstoffklasse: F (Tgrenz = 155 °C) Insulation class: F (max. permissible
temperature = 155 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 600 according to: VDE 0110 C 600
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Bei Ausführung mit Standard-Hubbe- Stroke of version with standard stroke
grenzung Hub 25 mm. limiter: 25 mm.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer( ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)


Nennaufnahme P 20 W 51 102 194 303 748 W Nominal coil power P 20
Anzugszeit (ED) ms 85 38 ms Actution time (ED)
1) 1)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface the duty cycle can be extended (please
ask for advice)

2000 %ED

1000
700
500

5
Kraft-Weg-Diagramm F = f (s) 200 Force vs. Stroke diagramm F = f (s)
15
25
W = Waagerechte Kennlinie 100 40 W = horizontal characteristic

50
100
F [N]

Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 20 position, at 90 % rated voltage and winding at
Wicklung operating temperature
10
Hub s = 0 entspricht dem angezogenen, bestromten 0 5 10 15 20 25 30 stroke s = 0 corresponds to armature in fully home
Zustand S [mm] position

Magnet Hauptkatalog 122 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 090 RM 090

ohne Anschlagdeckel without end stop

M12 Ø55
40
80
5
11

251
106
95

94
11

23
5

12

Direction of stroke
66
40

60
55
Hubrichtung

M12
Ø52 Ø55
Ø9,5
M6

100
Ø52
Ø90
Ø68

30

80
19

mit Anschlagdeckel with end stop

M12 Ø55
40
80
5

Direction of stroke
11
Hubrichtung

125

136
124
53
5

12
55
40

12

M12
Ø52 Ø55
Ø9,5
M6

100
Ø52
Ø90
Ø68

30

80
19

Magnet Hauptkatalog 123 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 100 RM 100

Hochleistungs-Hubmagnet RM 100 Heavy duty linear solenoid RM 100

Gewicht: Weight:
Magnet: ca. 6400 g Complete
solenoid: appr. 6400 g
Anker: ca. 1100 g Armature: appr. 1100 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 20 cm Flying leads: 20 cm
Isolierstoffklasse: F (Tgrenz = 155 °C) Insulation class: F (max. permissible
temperature = 155 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 450 according to: VDE 0110 C 450
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Service-free DU armature bearing for


(DU-Lager) für höchste Lebensdauer. maximum durability.
Bei Ausführung mit Standard-Hubbe- Stroke of version with standard stroke
grenzung Hub 30 mm. limiter: 30 mm.
In Sonderausführung mit eingebauter Return spring optional.
Rückholfeder lieferbar.

Zul. rel. Einschaltdauer (ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)


Nennaufnahme P 20 W 69 162 255 400 1071 W Nominal coil power P 20
Anzugszeit (ED) ms 110 45 ms Actution time (ED)
1) 1)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface the duty cycle can be extended (please
ask for advice)

2000 %ED

1000
700
500
5

Kraft-Weg-Diagramm F = f (s) 200 15 Force vs. Stroke diagramm F = f (s)


25
40
W = Waagerechte Kennlinie 100
W = horizontal characteristic

50 100
F [N]

Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer position, at 90 % rated voltage and winding at
20
Wicklung operating temperature
10
Hub s = 0 entspricht dem angezogenen, bestromten 0 10 20 30 40 stroke s = 0 corresponds to armature in fully home
Zustand S [mm] position

Magnet Hauptkatalog 124 Main catalogue


Hochleistungs-Hubmagnet Heavy Duty Linear Solenoid
RM 100 RM 100

ohne Anschlagdeckel without end stop

M12 Ø60
50
95
6
12

294
110

109

122
12

24
6

13

Direction of stroke
71
77

65
50
Hubrichtung

M12 M12 Ø60


Ø58
Ø11,5
M8
Ø100

110
Ø58
Ø76

30

88
19

mit Anschlagdeckel with end stop

M12 Ø60
50
695

Direction of stroke
12
Hubrichtung

143

156
144

58
65 6

14

13
50

M12

Ø58 Ø60
Ø11,5
M8
Ø100

110
Ø58
Ø76

30

88
19

Magnet Hauptkatalog 125 Main catalogue


Hochleistungs-Umkehr-Hubmagnet Heavy Duty Two-Directional
URM 20 Linear Solenoid URM 20

Bestellformel URM 20 –F– 24 V DC 100 % ED Order specifications


Hubmagnet URM Linear solenoid
Bauart 20 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Nennspannung (Standardspannung)1) 24 Nominal voltage (standard voltage)1)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Die Magnete sind auf Anfrage bis 60 V DC Other voltages are available on request up to
lieferbar 60 V DC

Gewicht: Weight:
Magnet: ca. 105 g Complete
solenoid: appr. 105 g
Anker: ca. 19 g Armature: appr. 19 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm Flying leads: 10 cm
Isolierstoffklasse: B (Tgrenz = 130 °C) Insulation class: B (max. permissible
temperature = 130 °C)
Isolationsgruppe Insulation group
nach: VDE 0110 C 75 according to: VDE 0110 C 75
Prüfspannung: 800 V (eff) Test voltage: 800 V (eff)

Wartungsfreie Ankerlagerung Long life expectancy through plastic


(DU-Lager) für höchste Lebensdauer. bobbin armature bearing.

Zul. rel. Einschaltdauer (ED)2) % 100 45 25 15 5 % Perm. duty cycle (ED)2)


Nennaufnahme P 20 W 3,9 8 13,5 21 59 W Nominal coil power P 20
Anzugszeit (ED) ms 11 5 ms Actuation time (ED)
2) 2)
Bei Montage auf eine Kühlfläche ist eine höhere If solenoid is mounted directly onto a flat metal
ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is
permissible (please ask for advice)

100 %ED

50
F [N]

20
Force vs. Stroke diagramm F = f (s)
10 5
Kraft-Weg-Diagramm F = f (s)
5 15
25
45 Force measured when operating in horizontal
2 position, at 90 % rated voltage and with winding at
Kraft bei waagerechter Bewegungsrichtung und operating temperature
100
bei 90 % Nennspannung und betriebswarmer 1
Wicklung 0 1 2 3 stroke s = 0 corresponds to armature in
S [mm] fully home position

Magnet Hauptkatalog 126 Main catalogue


Hochleistungs-Umkehr-Hubmagnet Heavy Duty Two-Directional
URM 20 Linear Solenoid URM 20

21 21
M3

M3

SW14
M8
1 2

9
+0,6
20 2 55 –0,2 2 8 9 Ø16

96 ±0,5 Ø20

Maße gelten, wenn System 1 bestromt Dimensions given when system 1


current-carrying
<–––––––> <–––––––>
Hubrichtung Direction of stroke

Magnet Hauptkatalog 127 Main catalogue


Hochleistungs-Umkehr-Hubmagnet Heavy Duty Two-Directional
URM 50 Linear Solenoid URM 50

Bestellformel URM 50 –N– 24 V DC 100 % ED Order specifications


Hubmagnet URM Linear solenoid
Bauart 50 Design type
Anschlußart Coil terminals
Litze (Standardlänge 10 cm) F Flying leads (10 cm standard length)
Gerätestecker1) N Plug-in socket connection1)
Nennspannung (Standardspannung)2) 24 Nominal voltage (standard voltage)2)
Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)
1) 1)
Für Steckhülsen 6,3 DIN 46247 For socket 6.3 DIN 46247
2) 2)
Die Magnete sind auf Anfrage bis 230 V DC Other voltages are available on request up to
lieferbar 230 V DC

Gewicht: Weight:
Magnet: ca. 1200 g Complete
solenoid: appr. 1200 g
Anker: ca. 180 g Armature: appr. 180 g
Standard: Standard:
Spannung: 24 V DC Voltage: 24 V DC
Litze: 10 cm Flying leads: 10 cm
Isolierstoffklasse: B (Tgrenz = 130 °C) 0-N D Insulation class: B (max. permissible
RM5 % E
U 100 temperature = 130 °C)
=
Isolationsgruppe 24V Insulation group
nach: VDE 0110 C 75 according to: VDE 0110 C 75
Prüfspannung: 2500 V (eff) Test voltage: 2500 V (eff)

Wartungsfreie Ankerlagerung Long life expectancy through plastic


(DU-Lager) für höchste Lebensdauer. bobbin armature bearing.

Zul. rel. Einschaltdauer (ED)3) % 100 70 40 25 15 5 % Perm. duty cycle (ED)3)


Nennaufnahme P 20 W 15 24 38 56 89 280 W Nominal coil power P 20
3) Bei Montage auf eine Kühlfläche ist eine höhere 3) If solenoid is mounted directly onto a flat metal

ED zulässig (bitte anfragen) surface, an increase in relative duty cycle is


permissible (please ask for advice)

1000 %ED

500

200
Kraft-Weg-Diagramm F = f (s) Force vs. Stroke diagramm F = f (s)
5
100
15
50 25
F [N]

40
Kraft bei waagerechter Bewegungsrichtung und Force measured when operating in horizontal
bei 90 % Nennspannung und betriebswarmer 20 70 position, at 90 % rated voltage and with winding at
Wicklung 100 operating temperature
10
Hub s = 0 entspricht dem angezogenen, 0 2 4 6 8 stroke s = 0 corresponds to armature in
bestromten Zustand S [mm] fully home position

Magnet Hauptkatalog 128 Main catalogue


Hochleistungs-Umkehr-Hubmagnet Heavy Duty Two-Directional
URM 50 Linear Solenoid URM 50

30
ca.52 19

15 15
M5

M5

ca.72
ca.60
1 2

M4
30 104 Ø40
156 Ø50

Maße gelten, wenn System 1 bestromt Dimensions given when system 1


current-carrying
<–––––––> <–––––––>
Hubrichtung Direction of stroke

Magnet Hauptkatalog 129 Main catalogue


Hochleistungs-Hubmagnete Heavy Duty Linear Solenoids
Zubehör Typ RM Accessories for Series RM

53
Gerätesteckdose Z 801 Plug-in socket for the appliance
Kabelverschraubung SPG 9 PG9 16 Screw joint PG 9
für Kabeldurchmesser 6-8 mm for lead diameter 6-8 mm

Gerätesteckdose Z 811 Plug-in socket Z 811

Ø22,5
Gerätesteckdose mit eingebautem Plug-in socket with built-in
Si-Brückengleichrichter Si-bridge rectifier

35
Typ GDML 211-GB 1 Type GDML 211-GB 1

Zu beziehen bei: Obtainable from:


Firma Richard Hirschmann Firma Richard Hirschmann
Postfach 110 PO Box 110
73728 Esslingen 73728 Esslingen
M3

3,5
27,5

Flansch Flange
ØI

(Befestigungsschrauben werden (Mounting screws are part of the


mitgeliefert) shipment)
ØG

ØD
ØE
ØF
ØJ

L H
K B
A C

Bestellbezeichnung Order specification

Bestell- Maße (mm) Dimensions (mm) Order


Nr. Typ A B C D E F G H I J K L Type number
Z 839 RM 050 50,0 7,0 12,0 30,0 23,0 30,0 – – 4,8 4,3 42,0 40,0 RM 050 Z 839
Z 840 RM 060 70,0 8,0 13,0 35,0 29,0 35,0 60,5 1,0 5,8 5,3 54,0 45,0 RM 060 Z 840
Z 841 RM 070 80,0 10,0 15,0 38,0 32,5 38,0 70,5 1,0 7,0 5,3 62,0 52,0 RM 070 Z 841
Z 842 RM 080 90,0 12,0 17,0 45,0 38,0 45,0 80,5 1,0 9,5 6,4 72,0 62,0 RM 080 Z 842
Z 843 RM 090 100,0 12,0 17,0 52,0 43,0 52,0 90,5 1,0 9,5 6,4 80,0 68,0 RM 090 Z 843
Z 844 RM 100 110,0 13,0 19,0 58,0 49,0 58,0 100,5 1,0 11,5 8,4 88,0 76,0 RM 100 Z 844

Magnet Hauptkatalog 130 Main catalogue


Hochleistungs-Hubmagnete Heavy Duty Linear Solenoids
Zubehör Typ RM Accessories for Series RM

Anschlagdeckel H End stop


(Befestigungsschrauben werden ØJ G (Mounting screws are part of the
mitgeliefert) shipment)

ØE
ØF
I K
ØB D
ØA C

Bestellbezeichnung Order specification

Bestell- Maße (mm) Dimensions (mm) Order


Nr. Typ A B C D E F G H I J K Type number
Z 838 RM 050 50,0 40,0 20,0 15,0 23,0 30,0 5,5 11,0 M4 4,3 10,0 RM 050 Z 838
Z 845 RM 060 60,0 45,0 22,0 17,0 29,0 35,0 5,5 12,0 M5 5,3 10,0 RM 060 Z 845
Z 846 RM 070 70,0 52,0 24,0 19,0 33,0 38,0 5,5 15,0 M5 5,3 10,0 RM 070 Z 846
Z 847 RM 080 80,0 62,0 30,0 25,0 38,0 45,0 5,5 20,0 M5 5,3 10,0 RM 080 Z 847
Z 848 RM 090 90,0 68,0 35,0 30,0 43,0 52,0 5,5 25,0 M6 6,4 12,0 RM 090 Z 848
Z 849 RM 100 100,0 76,0 40,0 34,0 48,0 58,0 6,5 30,0 M8 8,4 14,0 RM 100 Z 849

E F
Gabelkopf Fork
ØD
C

B
A

Bestell- An-
2)
Nr. schluß
Order- A B C D E F Connec-
number tion G

1) 38.304 12 15 9 2,5 3,1 6 M3 1)


Gabelköpfe, verzinkt und gelb chromatiert, Forks are galvanised and chromed yellow.
werden ohne Mutter geliefert. Sicherung z. B. 37.304 23 29 16 5 5 10 M5 Supplied without a nut. Secure using e.g. Loctite
durch Loctite o.ä. 36.304 27 34 19 6 6 12 M6 or a simular product.
2) 2)
Weitere Ausführungen (> M10) auf Anfrage Further specifications (> M10) optional
35.3041) 32 42 26 8 8 16 M8
34.3042) 40 52 32 10 10 20 M10

Faltenbalge siehe Zubehör-Übersicht, Gaiters see accessories page 9


Seite 9

Magnet Hauptkatalog 131 Main catalogue


Magnet Hauptkatalog 132 Main catalogue