You are on page 1of 28

Safety Standard ISO13849-1 Certified*2(Corresponding to Category 2 to 4)

® *1

3 Port Solenoid Valve/ *1. Refer to page 2 for


compliant products.

Residual Pressure Release Valve RoHS


with Detection of Main Valve Position *2. Refer to page 2 for certified products.

With Detection of
Residual pressure
release valve

Main Valve Position


Category 2

The detecting function of the main valve position detects a Safety limit switch
mismatch between the input signal and valve operation.
VP542-X536

Redundant system can be When the dual residual pressure release valve is
used, if one of the valves fails to operate, the
constructed easily. other one releases residual pressure.
Category 3, 4

Dual Residual Pressure Release Valve With Soft Start-up Function Dual Residual Pressure Release Valve
VP544-X538 VP544-X555 VG342-X87
Residual pressure Residual pressure
release valve w release valve w
Residual pressure
Residual pressure
release valve q
release valve q

Safety limit
switch
Soft start-up
valve

Redundant System
A system in which even if one part fails, the whole system
will fulfill its required function. This is usually achieved by
having dual channels of operation, such as dual valves, dual
wiring, dual guard switches etc.

SeriesVP/VG
CAT.ES11-111A
Safety Standard ISO13849-1 Certified
3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG

With Detection of Main Valve Position (Category 2) Redundant system can be constructed easily. (Category 3, 4)
Category 2 S
 afety function can be accomplished by single channel and is automatically Category 3 It has redundancy so there is no loss of safety function with a single failure.
checked. The safety function must be checked before each use. An accumulation of
undetected faults can cause loss of safety function.
Category 4 It has redundancy so there is no loss of safety function with a single failure. The
safety function must be checked before each use. An accumulation of undetected
faults does not affect the safety function. (Higher DC and MTTFd than Category 3.)

Monitoring
I Input signal L O I1 Input signal L1 O1
Logical operation Logical operation
Input equipment Output signal Output equipment Input equipment Output equipment
equipment equipment Output signal
Monitoring
Cross monitoring
Monitoring
TE OTE I2 Input signal L2 O2
Logical operation
Testing equipment Output signal Output of test result Input equipment Output equipment
equipment Output signal

The detecting function of the main valve position detects a When the dual residual pressure release valve is used, if one of the
mismatch between the input signal and valve operation. valves fails to operate, the other one releases residual pressure.
Input equipment (I) : Detection equipment (sensor) of starting event Input equipment (I1, I2): Detection equipment (sensor) of starting event
Logical operation equipment (L) : Relay sequence circuit, PLC control program Logical operation equipment (L1, L2): Relay sequence circuit, PLC control program
Output equipment (O) : Solenoid valve, Electromagnetic switch, Output relay Output equipment (O1, O2): S  olenoid valve, Electromagnetic switch, Output relay
Recommended valve : VP542/742-X536 Recommended valve: VP544/744-X538, VG342-X87

Residual pressure release valve Residual pressure release valve w

Safety limit Safety limit


switch switch
Residual pressure
release valve q
VP542-X536 VP544-X538
* This product is component which is a part of a safety system and safety equipment is not guaranteed by this single unit alone.

Highly reliable construction Safety limit switch can be selected.


q The main valve position is detected by transferring the
main valve movement directly to the reed safety limit switch
with the rod.

Main valve Rod


Safety limit switch

Made by OMRON Made by Rockwell Automation

Conduit (VP series only) and M12 connector with 6 pins is


M12 connector (4 pin) types available.
w Long service life: B10d: 10 million times*
are available.
e The return spring releases the residual pressure securely
regardless of pressure level.
* For VP500/700, safety limit switch made by OMRON

With soft start-up function (-X555)


 A function to gradually increase the initial pressure Output Pressure (P2) vs Time Graph
of the pneumatic system has been added to the dual
Output

residual pressure release valve. P1


 Fixed orifice and variable throttle are available as a P2 reaches half of P1, and
then the main valve of the
throttle for adjusting the pressure increase. (ø1, ø1.5, ø2) soft start-up valve turns on.

Throttle Main valve Valve 1 Valve 2


Soft start-up valve: ON
P2 Valve 1, Valve 2: ON
1/2P1
P2

Soft start-up 1(P) Start supplying flow ad-


2(A) justed air with the throt-
valve tle by energizing valve 1
and valve 2.
VP544-X555 P1 Soft start-up valve: OFF
Valve 1, Valve 2: ON
Soft start-up
valve 0
Time
3(R) 3(R)

1
Safety Standard ISO13849-1 Certified
3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG

Standards and Enclosure


Standards
Safety limit switch Machinery Directive 2006/42/EC
Series Category
manufacturer
Enclosure
Harmonized EN ISO13849-1: 2008 EN ISO4414: EN983: 1996 + CE cUL RoHS
standards EN ISO13849-2: 2008 2010 A1: 2008
Residual Pressure OMRON Corporation
Release Valve 2 IP65
VP542/742-X536 Page 3 Rockwell Automation, Inc.

Dual Residual Pressure OMRON Corporation


Release Valve 3, 4 IP65
VP544/744-X538 Page 3 Rockwell Automation, Inc.

Dual Residual Pressure Release Valve OMRON Corporation


with Soft Start-up Function 3, 4 IP65
VP544/744-X555 Page 3 Rockwell Automation, Inc.
*
Dual Residual Pressure OMRON Corporation
Release Valve 3, 4 IP40
VG342-X87 Page 19 Rockwell Automation, Inc.

* Only port size 3/4"

Series Variations
Flow rate characteristics
Port C [dm3/(s·bar)]  1R2 (PRA)
Series Category Thread
size
5 10 15 20 25
Residual Pressure
Release Valve 3/8"
Rc,
8.9
VP542-X536
2 G,
Residual Pressure NPT
Release Valve 1/2" 15.1
VP742-X536
Dual Residual Pressure
Release Valve 3/8" 6.5
VP544-X538 Rc,
G,
Dual Residual Pressure NPT
Release Valve 1/2" 10.3
VP744-X538
Dual Residual Pressure Release
Valve with Soft Start-up Function 3, 4 3/8"
Rc,
5.2
VP544-X555
G,
Dual Residual Pressure Release NPT
Valve with Soft Start-up Function 1/2" 9.8
VP744-X555
Dual Residual Pressure Rc,
Release Valve 3/4" G, 26.6
VG342-X87 NPT

For details about Safety


Can be connected to Modular type Standard ISO13849-1,
refer to “Guide to Prod-
F.R.L. units.  Page 17 ucts Conforming to Inter-
national Standards” on
Applicable models* the SMC website.
OVP544/744-X538
OVP544/744-X555
* Please contact SMC for the VP542/742-X536.

Filter regulator Dual residual pressure


(Optional release valve with soft
accessory) start-up function

2
Safety Standard ISO13849-1 Certified
*

3 Port Solenoid Valve/Residual Pressure Release *R


 efer to page 2 for
compliant products.

Valve with Detection of Main Valve Position


VP500/700-X536, X538, X555
How to Order

Residual pressure release valve VP 5 4 2 R 5 D Z 1 03 M X536

Dual residual pressure release valve VP 5 4 4 R 5 D Z 1 03 MA X538

Dual residual pressure release


valve with soft start-up function VP 5 4 4 5 D Z 1 03 M X555
Thread Throttle
Series Nil Variable throttle
Nil Rc
5 VP500 10 ø1 fixed orifice
Body F G
7 VP700 15 ø1.5 fixed orifice
2 Body ported N NPT
20* ø2 fixed orifice
4 Base mounted
* VP700 only

Pilot
Nil Internal pilot
Voltage
R External pilot
5 24 VDC Safety limit switch/Wiring
Nil G1/2 (Made by OMRON)
Electrical entry M M12 connector (Made by OMRON)
D DIN terminal M12 connector
S1 (Made by Rockwell Automation)
Y DIN (EN175301-803) terminal
* Refer to page 18 for details about type Y.
With check valve (Only external pilot)
Light/surge voltage suppressor Check Applicable Thread
Z With light/surge voltage suppressor valve tube O.D. Rc G NPT
Nil None — V V V
Port size A ø6 V — —
Yes
B ø1/4* — — V
Port size VP500 VP700
03 3/8" V — * For internal pilot, the symbol is nil.
* Refer to “Piping for External Pilot Type” on page 4 for
04 1/2" — V
selection of the check valve.

Made to Order

1 Series Compatible with Secondary Batteries


For details about 25A-, refer to the WEB catalog “Series Compatible with Secondary Batteries/Series 25A-.”

How to Order X536


25A–VP 4  – 5DZ1 –  –  – X538
X555
Fill in according to How to Order above. Note) Electrical entry can be selected only for D type.
Check valve type is available only when the thread
Secondary battery compatible type is Rc.
3
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X536, X538, X555

Valve Specifications

VP500/700
Fluid Air
Type of actuation N.C. (Spring return)
Operation Internal pilot External pilot
Operating pressure range 0.25 to 0.7 MPa 0.25 to 0.7 MPa
External pilot pressure — 0.25 to 0.7 MPa (Same as operating pressure)
Maximum operating frequency 30 times/minute
Minimum operating frequency 1 time/week
Operating and ambient temperature −10 to 50°C (No freezing)
Ambient humidity 20 to 90%RH (No condensation)

Symbols
Manual override None
Pilot exhaust Individual exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance 150/30 m/s2

X536
Enclosure IP65
Operating environment Indoors
10000000 times (for the safety limit switch made by OMRON)
B10d (MTTFd calculation)
  1000000 times (for the safety limit switch made by Rockwell Automation)

X538
Internal Pilot Type Piping for External Pilot Type
Caution Caution
Valve may not operate properly when air sup- The product may not operate when the exter-
ply to P port is not adequate and the supply nal pilot pressure is insufficient due to simul-

X555
pressure to the valve is lower than 0.25 MPa, taneous operation or restricted air piping. In
the minimum operating pressure. Be careful this case, use the check valve (AKH series)
with insufficient supply pressure. with the external pilot port, change the piping
size or adjust the set pressure to provide a
constant pressure of 0.25 MPa or more.

Accessories
Flow Rate Characteristics / Weight

Optional
Flow rate characteristics
Weight
Series 1R2 (PRA) 2R3 (ARR)
[g]

Specific Product
C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv

Precautions
VP542-X536 8.9 0.16 2.2 8.9 0.20 2.1 350
VP742-X536 15.1 0.21 3.6 15.3 0.22 3.7 590
VP544-X538 6.5 0.08 1.3 6.7 0.10 1.3 930
VP744-X538 10.3 0.08 2.3 9.7 0.08 2.1 1510
VP544-X555 5.2 0.06 1.1 6.7 0.10 1.3 1105
VP744-X555 9.8 0.08 2.1 9.7 0.08 2.1 2000

VG342
Needle Valve / Flow Rate Characteristics (VP544/744-X555)

600
ø1 ø1.5 ø2
Flow rate (L/min [ANR])

500
0.7 MPa Symbols
400
0.5 MPa
300
0.25 MPa
200
X87

100

0
0 0.5 1 1.5 2 2.5 3 3.5 4
Number of needle rotations (Turns)
Specific Product
Precautions

Solenoid Specifications Safety Limit Switch Specifications

Electrical entry DIN terminal Manufacturer OMRON Rockwell Automation


Rated voltage 24 VDC Electrical wiring G1/2, M12 connector M12 connector
Allowable voltage fluctuation ±10% Contact resistance 25 mΩ or less 50 mΩ or less
Power consumption 0.45 W Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance)
Surge voltage suppressor Varistor Max. voltage 24 VDC
Indicator LED Max. load current 50 mA
Max. load inductance 0.5 H
Insulation voltage 300 V 600 V
Protection against electric shock Class II (EN60947-5-1: 2004)
4
VP500/700-X536, X538, X555

Symbols
Safety limit switch
Made by
OMRON

Symbol Terminal/Pin Numbers (Built-in switch  2N.C.)


w r M12 connector G1/2
(12) (32) Wiring specification Wiring specification
pin number terminal number

q (11)
11 12
w e w (12)

(11) (31) e r q (31) 31 32


q e
r (32)

VP542(R) /742(R)-X536
Internal pilot External pilot External pilot/With check valve
w r w r w r
2(A) (12) (32) 2(A) (12) (32) 2(A) (12) (32)

1(P) 3(R) (11) (31) 1(P) 3(R) (11) (31) 1(P) 3(R) (11) (31)
q e q e q e

Safety limit switch terminal [N.C.] X X


M12 connector pin number
G1/2 terminal number

VP544(R) /744(R)-X538
Internal pilot External pilot External pilot/With check valve
w r w r w r
2(A) (12) (32) 2(A) (12) (32) 2(A) (12) (32)

3(R) (11) (31) 3(R) (11) (31) 3(R) (11) (31)


q e q e q e
w r w r w r
(12) (32) (12) (32) (12) (32)

3(R) (11) (31) 3(R) (11) (31) 3(R) (11) (31)


q e q e q e

1(P) X 1(P) 1(P)


X

VP544(R) /744(R)-X555
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)

w r w r w r
(12) (32) (12) (32) (12) (32)

(11) (31) (11) (31) (11) (31)


q e q e q e
3(R) 3(R) 3(R)
w r w r w r
(12) (32) (12) (32) (12) (32)

(11) (31) (11) (31) (11) (31)


q e q e q e
3(R) 3(R) 3(R)

1(P) X 1(P) X 1(P)

5
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X536, X538, X555

Symbols

VP500/700
Safety limit switch
Made by
Rockwell Automation

Symbol Pin Numbers (Built-in switch  3N.C.)


t y r M12 connector
Wiring specification
pin number

Symbols
q
e
t y

q w e w r w
y

X536
e t q
r

X538
VP542(R)/742(R)-X536
Internal pilot External pilot External pilot/With check valve

X555
2(A) tyr 2(A) tyr 2(A) tyr

1(P) 3(R) qwe 1(P) 3(R) qwe 1(P) 3(R) qwe

Accessories
Optional
Safety limit switch terminal [N.C.] X X
M12 connector pin number

VP544(R)/744(R)-X538

Specific Product
Precautions
Internal pilot External pilot External pilot/With check valve
2(A) tyr 2(A) tyr 2(A) tyr

3(R) qwe 3(R) qwe 3(R) qwe

VG342
tyr tyr tyr

3(R) qwe 3(R) qwe 3(R) qwe

1(P) X 1(P) X 1(P)


Symbols
VP544(R)/744(R)-X555
Internal pilot External pilot External pilot/With check valve
2(A) 2(A) 2(A)

tyr tyr tyr


X87

qwe qwe qwe


3(R) 3(R) 3(R)
Specific Product
Precautions

tyr tyr tyr

qwe qwe qwe


3(R) 3(R) 3(R)

1(P) X 1(P) X 1(P)

6
VP500/700-X536

Dimensions Residual Pressure Release Valve (-X536)

VP542(R)-5 DY Z1-03l-l-X536
VP542(R)-5 DY Z1-03l-Ml-X536 3/8"
Port size: 1/8" (Without check valve)
[2(A) port]
Safety limit switch Applicable tube O.D.: ø6, ø1/4" (With check valve)
2 x ø4.2 31 (External pilot port)
Made by

3.5
(For mounting)

4.5
OMRON 26

22.1
118.9
(Max. 10) 201.8
Applicable cable O.D.
ø3.5 to ø7 Safety limit switch (made by OMRON)
Part number: D4N-2B31 (G1/2)
: D4N-9B31 (M12 connector)
2 x ø4.2

(25.7)
(For mounting) G1/2
70.8
63.3

(With check valve)


A
31.5

45
40

(22.9)
23.5 117.4
4

202.4 (14) (M12 connector)

(31.5
)
(Distan
ce
betwee
3/8" n ports View A
)
[1(P), 3(R) port] For M12 connector

e w
32
7

Pin
Vent port 30.7 r q
number
(ø6.2) 54.9 103.4

VP542(R)-5 DY Z1-03l-S1l-X536
3/8"
Port size: 1/8" (Without check valve)
Safety limit switch [2(A) port]
Applicable tube O.D.: ø6, ø1/4" (With check valve)
2 x ø4.2 31
Made by (External pilot port)
3.5

(For mounting)
Rockwell Automation
4.5
26

22.1
133.2
(Max. 10) 216.1
Applicable cable O.D.
ø3.5 to ø7 Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6

2 x ø4.2
(For mounting)
70.8
63.3

(With check valve)

A
31.5

45
40

25.2
(22.9)

23.5 131.7 M12 connector


4

216.7 8

(31.5
)
(Distan
ce
betwee
3/8" n ports View A
)
[1(P), 3(R) port] M12 connector
ye
32
7

r w

Vent port 30.7 Pin t q


(ø6.2) number
54.9 117.7

7
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X536

Dimensions Residual Pressure Release Valve (-X536)

VP742(R)-5 DY Z1-04l-l-X536

VP500/700
1/2"

VP742(R)-5 DY Z1-04l-Ml-X536 [2(A) port]


Port size: 1/8" (Without check valve)
44.5
Applicable tube O.D.: ø6, ø1/4" (With check valve)
Safety limit switch ø5.2 3.5 (External pilot port)
(For mounting)
Made by

7.5
OMRON 4.5

33
20.5 108.4

3.5

Symbols
(Max. 10) 224.2
Applicable cable O.D.
Safety limit switch (made by OMRON)
ø3.5 to ø7
Part number: D4N-2B31 (G1/2)
: D4N-9B31 (M12 connector)

X536
ø5.2
(For mounting)
G1/2
88.8
81.3

(With check valve)


A
38.5

56.5
63

(34.7)

X538
(22.9)
31 128.9 (14) (M12 connector)
9.4

224.8
(43)

X555
(Distanc
e
between
1/2" ports)
[1(P), 3(R) port] View A
For M12 connector

Accessories
40

Optional
9

e w

Vent port 42 Pin


r q
(ø6.2) number
73.5 107.9

Specific Product
Precautions
VP742(R)-5 DY Z1-04l-S1l-X536
1/2"
[2(A) port] Port size: 1/8" (Without check valve)
Safety limit switch
Applicable tube O.D.: ø6, ø1/4" (With check valve)
Made by 2 x ø5.2 41 (External pilot port)
4.5

(For mounting)
Rockwell Automation

VG342
7.5
33

24
143.2
(Max. 10) 238.5
Symbols
Applicable cable O.D.
ø3.5 to ø7 Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6
2 x ø5.2
(For mounting)
X87
88.8
81.3

(With check valve)

A
38.5

56.5
63

34.2
(22.9)

Specific Product
Precautions

31 143.2 8 M12 connector


9.4

239.1
(43)
(Distanc
e
between
1/2" ports)
View A
[1(P), 3(R) port]
M12 connector

ye
40
9

r w

Vent port 42 Pin t q


(ø6.2) number
73.5 122.2

8
VP500/700-X538

Dimensions Dual Residual Pressure Release Valve (-X538)

VP544(R)-5 DY Z1-03l-l-X538
VP544(R)-5 DY Z1-03l-Ml-X538

17.5
Safety limit switch 3/8" 28.5
[2(A) port]
Made by Safety limit switch (made by OMRON)
OMRON Part number: D4N-2B31 (G1/2)
: D4N-9B31 (M12 connector)

Port size: 1/8" (Without check valve)


Applicable tube O.D.: ø6, ø1/4" (With check valve) 2 x 3/8"
(External pilot port) [3(R) port]
47 5 (M12 connector)
Applicable cable O.D. 2 x ø5.2 G1/2
ø3.5 to ø7 (For mounting)

Channel 2
33.5

75.5
91.5

62.5
Channel 1
29

29
18

11.3 (90.4) 17.5

8
97.3 (Max. 10) 201.8 (14) 28.2
(59.7)

A
104.8
79

34

View A
Vent port For M12 connector
17.5

(ø6.2) e w
28.5 3/8"
(22.9) 57 [1(P) port] Pin
r q
(With check valve) number
112 90.4

9
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X538

Dimensions Dual Residual Pressure Release Valve (-X538)

VP544(R)-5 DY Z1-03l-S1l-X538

VP500/700
Safety limit switch

17.5
3/8" 28.5
Made by
[2(A) port]
Rockwell Automation
Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6

Symbols
Port size: 1/8" (Without check valve)
Applicable tube O.D.: ø6, ø1/4" (With check valve)
(External pilot port)
47 5 (104.7) 8 2 x 3/8"

X536
2 x ø5.2 M12 connector
Applicable cable O.D. [3(R) port]
ø3.5 to ø7 (For mounting)

Channel 2
33.5

75.5
91.5

X538
62.5
Channel 1
29

29
18

11.3 (Max. 10) 216.1 17.5

X555
97.3 28.2
59.2

Accessories
Optional
A
104.8
79

Specific Product
View A
34

Precautions
M12 connector
Vent port
ye
17.5

(ø6.2) r w
28.5 3/8"
(22.9) 57 [1(P) port] Pin t q
(With check valve) number
112 104.7

VG342Symbols
X87
Specific Product
Precautions

10
VP500/700-X538

Dimensions Dual Residual Pressure Release Valve (-X538)

VP744(R)-5 DY Z1-04l-l-X538
VP744(R)-5 DY Z1-04l-Ml-X538
1/2" 40
Safety limit switch
[2(A) port]
Made by

18
Safety limit switch (made by OMRON)
OMRON
Part number: D4N-2B31 (G1/2)
: D4N-9B31 (M12 connector)

Port size: 1/8" (Without check valve)


Applicable tube O.D.: ø6, ø1/4" (With check valve) 2 x 1/2"
(External pilot port) [3(R) port]
2 x ø6.2 67 6.5 (M12 connector)
Applicable cable O.D. G1/2
(For mounting)
ø3.5 to ø7

Channel 2

113.5
41.5

94.5

77.5
Channel 1
36

36
21

9.5
16 (88.9) 18
117.3 (Max. 10) 224.2 (14) 27.2
(70.7)

A
124.8

99

View A
36

For M12 connector


18

Vent port e w
1/2"
(ø6.2) 40 [1(P) port]
(22.9) 80 88.9 r q Pin
number
(With check valve) 224.8

11
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X538

Dimensions Dual Residual Pressure Release Valve (-X538)

VP744(R)-5 DY Z1-04l-S1l-X538

VP500/700
Safety limit switch
1/2" 40
Made by [2(A) port]
Rockwell Automation

18
Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6

Symbols
Port size: 1/8" (Without check valve)

X536
Applicable tube O.D.: ø6, ø1/4" (With check valve) (103.2)
(External pilot port)
2 x ø6.2 67 6.5 M12 connector 2 x 1/2"
Applicable cable O.D. (For mounting) [3(R) port]
ø3.5 to ø7

X538
Channel 2

113.5
41.5

94.5

77.5
Channel 1

X555
36

36
21

9.5
16 18

Accessories
117.3 (Max. 10) 238.5 8 27.2

Optional
70.2

Specific Product
Precautions
A
124.8

99

View A
M12 connector
36
18

y e

VG342
Vent port 1/2" r w
(ø6.2) 40 [1(P) port]
(22.9) 80 Pin t q
number
(With check valve) 135.9 103.2

Symbols
X87
Specific Product
Precautions

12
VP500/700-X555

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555)

VP544(R)-5 DY Z1-03l-ll-X555
VP544(R)-5 DY Z1-03l-Mll-X555
3/8" 28.5
Safety limit switch [2(A) port]
Safety limit switch (made by OMRON)
Made by

(15)

15
Part number: D4N-2B31 (G1/2)
OMRON : D4N-9B31 (M12 connector)

Port size: 1/8" (Without check valve)


Applicable tube O.D.: ø6, ø1/4" (With check valve) 2 x 3/8"
(External pilot port) [3(R) port]
47 5 (M12 connector)
Applicable cable O.D. 2 x ø5.2 G12
(ø3.5 to ø7) (For mounting)
33.5

109
125

96
62.5

62.5
35

15 (Variable throttle type) (90.4) 15.5 Vent port

8
93.8 (Max. 10) 201.8 (14) 24.2 (ø6.4)
56.2
101.3
75.5

View A
30.5
24.2

For M12 connector


(15)

15

Vent port 3/8" e w


(ø6.2) [1(P) port]
(22.9) 28.5 90.4 r q Pin
(With check valve) number
202.4

13
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X555

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555)

VP544(R)-5 DY Z1-03l-S1ll-X555

VP500/700
Safety limit switch 3/8" 28.5
[2(A) port]
Made by
Safety limit switch (made by Rockwell Automation)

(15)

15
Rockwell Automation Part number: 440P-CDPB03R6

Symbols
Port size: 1/8" (Without check valve)
Applicable tube O.D.: ø6, ø1/4" (With check valve)

X536
(External pilot port) 2 x 3/8"
2 x ø5.2 M12 connector
Applicable cable O.D. [3(R) port]
(ø3.5 to ø7) (For mounting)

X538
33.5

109
125

96
62.5
62.5

X555
35

15 (Variable throttle type) (90.4) 15.5 Vent port

8
93.8 (Max. 10) 216.1 8 24.2 (ø6.4)

Accessories
Optional
55.7

Specific Product
Precautions
101.3
75.5

View A
M12 connector
30.5
24.2

y e
(15)

15

Vent port 3/8" r w

VG342
(ø6.2) [1(P) port]
(22.9) Pin t q
28.5 90.4
number
(With check valve) 216.7

Symbols
X87
Specific Product
Precautions

14
VP500/700-X555

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555)

VP744(R)-5 DY Z1-04l-ll-X555
VP744(R)-5 DY Z1-04l-Mll-X555
Safety limit switch 1/2" 40
[2(A) port]
Made by

18
OMRON Safety limit switch (made by OMRON)
Part number: D4N-2B31 (G1/2)
: D4N-9B31 (M12 connector)

Port size: 1/8" (Without check valve)


Applicable tube O.D.: ø6, ø1/4" (With check valve)
2 x 1/2"
(External pilot port)
2 x ø6.2 67 6.5 (M12 connector) [3(R) port]
Applicable cable O.D.
(For mounting) G1/2
ø3.5 to ø7
41.5

136
155

119
77.5

77.5
44.4

18 18.5 Vent port


9.5

117.3 (Variable throttle type) (88.9) 27.2 (ø6.4)


(Max. 10) 224.2 (14) 70.7
124.8
99

View A
36
27.2

For M12 connector


18

e w
Vent port 1/2"
(ø6.2) [1(P) port]
(22.9) 40 88.9 r q Pin
number
(With check valve) 224.8

15
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VP500/700-X555

Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555)

VP744(R)-5 DY Z1-04l-S1ll-X555

VP500/700
Safety limit switch
Made by
Rockwell Automation 1/2" 40
[2(A) port]

18
Safety limit switch (made by Rockwell Automation)
Part number: 440P-CDPB03R6

Symbols
A

X536
Port size: 1/8" (Without check valve)
Applicable tube O.D.: ø6, ø1/4" (With check valve)
(External pilot port) 2 x 1/2"

X538
2 x ø6.2 67 6.5 M12 connector
Applicable cable O.D. [3(R) port]
(For mounting)
ø3.5 to ø7

X555
41.5

136
155

119

Accessories
Optional
77.5

77.5
44.4

Specific Product
18 18.5 Vent port

Precautions
9.5

117.3 (Variable throttle type) (86.3) 27.2 (ø6.4)


(Max. 10) 236.4 8 70.2

VG342
124.8
99

View A
M12 connector
36
27.2
18

y
e Symbols
Vent port 1/2" r w
(ø6.2) [1(P) port]
(22.9) 40 86.3 Pin t q
(With check valve) number
245
X87
Specific Product
Precautions

16
VP500/700-X538, X555
Optional Accessories
For details about optional accessories, refer to the WEB catalog.

Piping Adapter: 3/8, 1/2 Spacer with Bracket


A piping adapter allows installation/removal of the component D
without removing the piping and thus makes maintenance easier. H K
F J
Port size

G
Center of
Center of F.R.L.
B

C
body

E
F.R.L.
body

B
A D

E
Part no. Note) Port size A B D
E300-l03-A 3/8 31.8 30 30
Seal
E400-l04-A 1/2 31.8 36 36
A
Note) l in part numbers indicates a pipe thread type. (Spacer width)
No indication is necessary for Rc; however,
indicate N for NPT, and F for G. Part no. A B C D E F G H J K
∗ Separate interfaces are required for modular unit. Y300T-A 4.2 82 41 71.5 35 14 7 19 4 41
Y400T-A 5.2 96 48 86.1 40 18 9 26 5 50

Ordering Example∗ Dual residual pressure release valve


with soft start-up function
VP544-5DZ1-03-X538 ········ 1 pc.
Filter regulator
AW30-03G-A · ···················· 1 pc.
Spacer with bracket
Spacer with bracket
Y300T-A ····························· 3 pcs.
Piping adapter
E300-03-A ·························· 2 pcs.

* Each product is not assembled.


Piping
adapter

Spacer with Bracket Mounting Position


Dual residual pressure release valve (-X538) Dual residual pressure release valve with soft start-up function (-X555)
(Max. 10)

(Max. 10)
82.9

82.9

IN OUT IN OUT
201.8

201.8

a b c a b c
(14)

(14)

d d

Model a b c d Note Model a b c d Note


AW30-03G-A AW30-03G-A
VP544-5DZ1-03-X538 33.9 57.2 95.7 220.7 Y300T-A VP544-5DZ1-03-X555 33.9 57.2 129.2 254.2 Y300T-A
E300-03-A E300-03-A
AW40-04G-A AW40-04G-A
VP744-5DZ1-04-X538 34.4 75.2 118.7 262.7 Y400T-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 Y400T-A
E400-04-A E400-04-A
17
VP500/700-X536, X538, X555
Specific Product Precautions
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

VP500/700
How to Use DIN Terminal Connector Light/Surge Voltage Suppressor
DIN Terminal
Caution With light (DZ)
Connection (YZ)
1. Loosen the holding screw and pull the connector out of the No.1
solenoid valve terminal block. (–)(+)

Symbols
2. After removing the holding screw, insert a flat blade
screwdriver etc. into the notch on the bottom of the terminal Varistor Coil
block and pry it open, separating the terminal block and the No.2
housing. (+)(–) LED
3. Loosen the screw (slotted screws) in the terminal block. Insert There is no polarity.
the lead core wires to the terminals according to the connection

X536
method, and secure the wires by re-tightening the terminal Note) Surge voltage suppressor of varistor has residual voltage
screw. corresponding to the protective element and rated voltage;
4. Secure the cord by fastening the ground nut. therefore, protect the controller side from the surge voltage.

Caution

X538
Limit Switch Cable
When making connections, please note that using other than the
supported size (ø3.5 to ø7) heavy-duty cord will not satisfy IP65 OMRON or Rockwell Automation M12 connector limit switch ca-
(enclosure) standards. Also, be sure to tighten the ground nut ble is available.
and holding screw within their specified torque ranges. M12 Connector Cable (4 Pins) Made by OMRON

X555
Changing the entry direction Part number Cable length [mm]
ZS-37-L 300
After separating the terminal block and housing, the cord entry
can be changed by attaching the housing in the desired direction ZS-37-M 500
ZS-37-N 1000

Accessories
(4 directions at 90° intervals).

Optional
ZS-37-P 2000
* When equipped with a light, be careful not to damage the light
ZS-37-C 5000
with the cord’s lead wires.

Precautions M12 Connector Cable (6 Pins) Made by Rockwell Automation

Specific Product
Plug in and pull out the connector vertically without tilting to one Part number Cable length [mm]

Precautions
side. VP500-231-1 2000

Compatible cable
Cord O.D.: ø3.5 to ø7
(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306 Installation
Use the external pilot type when using VP500/700-X536 or X538
with AV series. Install the AV series to the primary side.

VG342
Ground nut
Tightening torque
1.65 to 2.5 N·m
Holding screw
Tightening torque
Washer 0.4 N·m

Grommet
(Rubber) Housing
Symbols
Voltage symbol (Position for light
Type D: 24 V mounting)
Type Y: 24 VN
Terminal block
Terminal screw Notch
(3 locations)
X87

Tightening torque
0.2 to 0.25 N·m

Type “Y”
Specific Product
Precautions

DIN connector type Y is a DIN connector that confirms to the DIN


pitch 8-mm standard.
• D type DIN connector with 9.4 mm pitch between terminals is
not interchangeable.
• To distinguish from the D type DIN connector, “N” is listed at the
end of voltage symbol.
• Dimensions are completely the same as D type DIN connector.

18
Safety Standard ISO13849-1 Certified
*

3 Port Solenoid Valve/Residual Pressure Release *R


 efer to page 2 for
compliant products.

Valve with Detection of Main Valve Position


VG342-X87

How to Order

Dual residual pressure release valve VG342 R 5 D Z 06 M X87

Pilot Safety limit switch/Wiring


Nil Internal pilot M12 connector
M (Made by OMRON)
R External pilot
M12 connector
S1 (Made by Rockwell Automation)
Voltage
5 24 VDC
Thread
Electrical entry Nil Rc
D DIN terminal F G
N NPT

Light/surge voltage suppressor


Z With light/surge voltage suppressor With check valve (Only external pilot)
Check Applicable Thread
valve tube O.D. Rc G NPT
Port size
06 3/4" Nil None — V V V
10 1" A ø8 V — —
Yes
B ø5/16" — — V
* For internal pilot, the symbol is nil.
* Refer to “Piping for External Pilot Type” on page 20 for
selection of the check valve.

Made to Order

1 Series Compatible with Secondary Batteries


For details about 25A-, refer to the WEB catalog “Series Compatible with Secondary Batteries/Series 25A-.”

How to Order

25A–VG342 – 5DZ –  – M – X87

Fill in according to How to Order above. Note) Electrical entry can be selected only for D type.
Check valve type is available only when the thread
Secondary battery compatible type is Rc.

19
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VG342-X87

Valve Specifications

VP500/700
Fluid Air
Type of actuation N.C. (Spring return)
Operation Internal pilot External pilot
Operating pressure range 0.25 to 0.7 MPa 0.25 to 0.7 MPa
0.25 to 0.7 MPa
External pilot pressure —
(Same as operating pressure)
Maximum operating frequency 30 times/minute
Minimum operating frequency 1 time/week

Symbols
Operating and ambient temperature −10 to 50°C (No freezing)
Ambient humidity 95%RH or less (No condensation)
Manual override None
Pilot exhaust Individual exhaust

X536
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance 150/50 m/s2
Enclosure IP40
Operating environment Indoors

X538
Weight 2.8 kg 2.9 kg
B10d (MTTFd calculation) 900000 times

Internal Pilot Type

X555
Caution
Valve may not operate properly when air supply to P port is not adequate and the supply pressure
to the valve is lower than 0.25 MPa, the minimum operating pressure. Be careful with insufficient
supply pressure.

Accessories
Optional
Piping for External Pilot Type
Caution
The product may not operate when the external pilot pressure is insufficient due to simultaneous

Specific Product
operation or restricted air piping. In this case, use the check valve (AKH series) with the external

Precautions
pilot port, change the piping size or adjust the set pressure to provide a constant pressure of 0.25
MPa or more.

Flow Rate Characteristics

VG342
Flow rate characteristics
1R2 (PRA) 2R3 (ARR)
Series
C C
b Cv b Cv
[dm3/(s·bar)] [dm3/(s·bar)]
VG342-X87 26.6 0.04 5.5 28.6 0.03 5.6

Symbols

Solenoid Specifications Safety Limit Switch Specifications

Electrical entry DIN terminal Manufacturer OMRON Rockwell Automation


X87

Rated voltage 24 VDC Electrical wiring M12 connector


Allowable voltage –15% to +10% of Contact resistance 25 mΩ or less 50 mΩ or less
fluctuation rated voltage Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance)
Power consumption 2.2 W Max. voltage 24 VDC
Specific Product
Precautions

Suppressor Diode Max. load current 50 mA


Indicator LED Max. load inductance 0.5 H
Insulation voltage 300 V 600 V
Protection against electric shock Class II (EN60947-5-1: 2004)

20
VG342-X87

Symbols
Safety limit switch
Made by
OMRON

Symbol Pin Numbers (Built-in switch  2N.C.)


w r M12 connector
Wiring specification
pin number

w e w

q e
e r q

VG342(R)-X87
Internal pilot External pilot External pilot/With check valve
2(A) wr 2(A) wr 2(A) wr

3(R) qe 3(R) qe 3(R) qe

wr wr wr

3(R) qe 3(R) qe 3(R) qe

1(P) Safety limit switch terminal [N.C.] X 1(P) 1(P)


M12 connector pin number X

Safety limit switch


Made by
Rockwell Automation

Symbol Pin Numbers (Built-in switch  3N.C.)


t y r M12 connector
Wiring specification
pin number
q
e
t y

q w e w r w
y
e t q
r

VG342(R)-X87
Internal pilot External pilot External pilot/With check valve
2(A) tyr 2(A) tyr 2(A) tyr

3(R) qwe 3(R) qwe 3(R) qwe

tyr tyr tyr

3(R) qwe 3(R) qwe 3(R) qwe

1(P) X 1(P) X 1(P)

21
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VG342-X87

Dimensions Dual Residual Pressure Release Valve (-X87)

VP500/700
VG342(R)-5DZ-06l-Ml-X87
Safety limit switch 75 42.3

Made by
OMRON

34
74

Symbols
Port size: 1/8" (Without check valve)
Applicable tube O.D.: ø8, ø5/16" (With check valve)

X536
(External pilot port)
64.5 Channel 2 Channel 1
Safety limit switch (made by OMRON)
34 A
Part number: D4N-9B31
M12 x 1
Pg9 Applicable cable O.D.

X538
ø4.5 to ø7

X555
(190.9: For external pilot)
Vent port (75) (48.2)
214.1

Should be normally open.

175.9
3 x ø8.5

Accessories
Optional
(Mounting hole)
(Max. 3) 3 3
(27.7) (106.6)
57.6

41.5
(69.5)

2 1

Specific Product
56
43.8

43.8

Precautions
(11.4)
28
21

37.5 73 73 10 37.5
77 75 45.5 3/4"
3/4" 2 x 3/4" [3(R) port] 164.5 [1(P) port]
[2(A) port] Should be normally open.

VG342
View A
M12 connector

e w
Symbols
r q Pin
number
X87
Specific Product
Precautions

22
VG342-X87

Dimensions Dual Residual Pressure Release Valve (-X87)

VG342(R)-5DZ-10l-Ml-X87
Safety limit switch 75 75.3

Made by
OMRON

34
74

Port size: 1/8" (Without check valve)


Applicable tube O.D.: ø8, ø5/16" (With check valve)
(External pilot port)
64.5 Channel 2 Channel 1
Safety limit switch (made by OMRON)
34 A
Part number: D4N-9B31
M12 x 1
Pg9 Applicable cable O.D.
ø4.5 to ø7

16.6

(190.9: For external pilot)


Vent port (75) (76.2)
Should be normally open.
214.1

175.9
3 x ø8.5
(Mounting hole)
(Max. 3) 3 3 (106.6)
(27.7)
41.5
(69.5)

2 1
56
43.8

43.8
28

37.5 Adapter 73 73 38 37.5


18.6

77 75 43.5 30 (5) 1"


1" 2 x 1" [3(R) port] 30 160.5 [1(P) port]
[2(A) port] Should be normally open. 220.5
230.5

View A
M12 connector

e w

r q Pin
number

23
Safety Standard ISO13849-1 Certified  3 Port Solenoid Valve/
Residual Pressure Release Valve with Detection of Main Valve Position VG342-X87

Dimensions Dual Residual Pressure Release Valve (-X87)

VP500/700
VG342(R)-5DZ-06l-S1l-X87
75 42.3
Safety limit switch
Made by
Rockwell Automation

34
74

Symbols
Port size: 1/8" (Without check valve)
Applicable tube O.D.: ø8, ø5/16" (With check valve)

X536
(External pilot port)
64.5 Channel 2 Channel 1 Safety limit switch
A (made by Rockwell Automation)
34
M12 x 1 Part number: 440P-CDPB03R6
Pg9 Applicable cable O.D.

X538
ø4.5 to ø7

X555
(190.9: For external pilot)
Vent port (75) (48.2)
218.7

Should be normally open.

175.9
3 x ø8.5

Accessories
Optional
(Mounting hole)
(Max. 3) 3 3
(27.7) (106.6)
57.6

41.5
(69.5)

2 1

Specific Product
56
43.8

43.8

Precautions
(11.4)
28
21

37.5 73 73 10 37.5
77 75 45.5 3/4"
3/4" 2 x 3/4" [3(R) port] 164.5 [1(P) port]
[2(A) port] Should be normally open.

VG342
View A
M12 connector

y e
r w Symbols
Pin
q
number t
X87
Specific Product
Precautions

24
VG342-X87

Dimensions Dual Residual Pressure Release Valve (-X87)

VG342(R)-5DZ-10l-S1l-X87
75 75.3
Safety limit switch
Made by
Rockwell Automation

34
74

Port size: 1/8" (Without check valve)


Applicable tube O.D.: ø8, ø5/16" (With check valve)
(External pilot port)
Channel 2 Channel 1 Safety limit switch
64.5
A (made by Rockwell Automation)
34 Part number: 440P-CDPB03R6
M12 x 1
Pg9 Applicable cable O.D.
ø4.5 to ø7

(13.4)

175.9: For internal pilot


Vent port (75) (76.2)
218.7

Should be normally open.

190.9
3 x ø8.5
(Mounting hole)
(Max. 3) 3 3
(27.7) (106.6)
41.5
(69.5)

N
2 1
56
43.8

43.8
28

37.5 73 73 38 37.5
18.6

77 75 43.5 30 (5) 1"


1" 2 x 1" [3(R) port] 30 160.5 [1(P) port]
[2(A) port] Should be normally open. 220.5
230.5

View A
M12 connector

y e
r w
Pin
t q
number

25
VG342-X87
Specific Product Precautions
Be sure to read this before handling. Refer to the back cover for Safety Instructions.
For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC
Products” and the Operation Manual on the SMC website, http://www.smcworld.com

VP500/700
How to Use DIN Terminal Connector Light/Surge Voltage Suppressor

Caution Terminal number 1


(+)
Connection Coil
1. Loosen the holding screw and pull the connector out of the
solenoid valve terminal block. Terminal number 2

Symbols
2. After removing the holding screw, insert a flat blade (–)
screwdriver etc. into the notch on the bottom of the terminal
block and pry it open, separating the terminal block and the
housing.
3. Loosen the screw in the terminal block. Insert the lead core Limit Switch Cable
wires to the terminals, and secure the wires by re-tightening

X536
OMRON or Rockwell Automation M12 connector limit switch ca-
the terminal screw. ble is available.
As the product has polarity, referring to the electric circuit
diagram, wire the product correctly as per the symbol of the M12 Connector Cable (4 Pins) Made by OMRON
terminal No. of the terminal block. Part number Cable length [mm]
4. Secure the cord by fastening the ground nut.

X538
ZS-37-L 300
Tighten the ground nut and holding screw within the specified ZS-37-M 500
range of torque. ZS-37-N 1000
Changing the entry direction ZS-37-P 2000
ZS-37-C 5000
After separating the terminal block and housing, the cord entry

X555
can be changed by attaching the housing in the opposite direction
180°. M12 Connector Cable (6 Pins) Made by Rockwell Automation
* Be careful not to damage the element etc. with the cord’s lead Part number Cable length [mm]
wires. VP500-231-1 2000

Accessories
Optional
Precautions
Plug in and pull out the connector vertically without tilting to one
side.

Specific Product
Compatible cable

Precautions
Cord O.D.: ø4.5 to ø7 (Reference) 0.5 to 1.5 mm 2, 2-core or
3-core, equivalent to JIS C 3306

Applicable crimped terminals


O-terminals: Equivalent to R1.25-4M defined in the JIS C 2805
Y-terminals: Equivalent to 1.25-3L made by J.S.T. Mfg. Co., Ltd.
Rod-terminals: Up to size 1.5

VG342
Ground nut
Holding screw
Tightening torque
2.5 to 3.75 N·m Tightening torque
0.5 to 0.6 N·m

Washer Housing
Grommet
(Rubber)
Symbols

Terminal block
Terminal number
Terminal screw
3 locations
X87

Tightening torque
0.4 to 0.5 N·m
Specific Product
Precautions

26
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.

Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

You might also like