DSC Technical Note – Contact ID Codes

DSC TECHNICAL SUPPORT


ALARMCOM (02) 9564 5812 or 1800 252 960
If you are required to change a reporting code to the central station, then the Contact ID uses
auto reporting code option must be turned OFF in section [381] zone LED 7 ON. This means
that all required reporting codes will need to be programmed, if no report is required (ie
open/close) then this section does not require programming: :

[320] Alarm Reporting Codes: enter the last 2 digits of the required report in each
location for zone 1, zone 2, zone 3, zone 4, zone 5 and zone 6. Reporting codes would
be one of the following:
Medical *11*
Fire alarm 1*1*, Fire smoke detector 11, Fire heat detector 14,
Fire button 1*1*
Panic alarm 2*1*, Duress alarm 21
Burglary 3*1*, Perimeter 31, Interior 32, 24 hour 33, Entry exit 34, Tamper 37,
For example if the zones are 1- entry/exit, 2 - interior, 3 - burglary, 4 - panic, 5 -
smoke sensor and 6 tamper the codes programmed into [320] & [324] would be :
[34], [32], [3*1*], [2*1*], [1*1*], [37], [#]
_____________________________________________________________________
[324] Alarm Restoral Reporting Codes: same codes are entered as for Alarm
Reporting Codes
_____________________________________________________________________
[328] Miscellaneous Reporting Codes: 21,*1*6, 59, #
_____________________________________________________________________
[329] Priority Alarm & Restorals: 1*1*, *11*, 2*1*, 2*1*, 1*1*, *11* , 2*1*, 2*1*
_____________________________________________________________________
[330] to [337] Tamper Alarm & Restorals: This is only required if Double End of
Line or DSC Wireless is used, if it is then 44 is programmed into each zone location
_____________________________________________________________________
[338] Miscellaneous Tamper Reporting Codes: 45, 45, 21
_____________________________________________________________________
[339] to [348] Opening & Closing Codes: These are only required if the system is
required to report openings and closings. If openings and closings are require then
*1* 2 is programmed into each opening and close location In location 343, 7*1*
must be programmed into 6 to report partial close (Bypass/isolation).
_____________________________________________________________________
[349] Maintenance Alarm Reporting Codes: *1* 2,*1* 1, 21, 73, *11*, 00, 00, 33
_____________________________________________________________________
[350] Maintenance Alarm Restoral Codes: *1*2, *1*1, 21, 73, *11*, 51, 00, 33
_____________________________________________________________________
[351] Miscellaneous Maintenance Reporting Codes: 54, 54, 00, 00, 00, 72, 72,54

[352] Test Transmission Reporting Codes: *1*2, *1*2 #


_____________________________________________________________________
[353] Wireless Maintenance Report Codes: 84, 84
_____________________________________________________________________

1
Reporting Codes for ADT
DSC TECHNICAL SUPPORT (02) 9564 5812 or 1800 252 960
For a PC1565 utilising 6 zones without any opening/closings, single EOL and
without wireless, zone 5 reports fire, zone 6 reports tamper, the necessary input would
be:

320/324- Input zone reporting and restoral codes as required


(example):
320 - [34] [3*1*] [3*1*] [3*1*] [1*1*] [37] [#]
324 - [34] [3*1*] [3*1*] [3*1*] [1*1*] [37] [#]
328 - [21] [*1*6] [#]
329 - [1*1*] [*11*] [2*1*] [2*1*] [ 1*1*] [*11*] [2*1*] [2*1*]
349 - [*1*2] [*1*1] [21] [73] [*11*] [00] [00] [33]
350 - [*1*2] [*1*1] [21] [73] [*11*] [51] [00] [33]
351 - [54] [54] [00] [00] [00] [72] [72] [00]
352 – [*1*2] [*1*1] [#]
381 - Zone LED 7 ON (press button 7)[#]
_______________________________________________________
Note 1:
For zones 1 to 5 reporting as a burglary and zone 6 reporting tamper [320] & [324]
would be:

320 - [3*1*] [3*1*] [3*1*] [3*1*] [3*1*] [37] [#]


324 - [3*1*] [3*1*] [3*1*] [3*1*] [3*1*] [37] [#]
Other locations as above
____________________________________________________________________
Note 2:

Using the PGM2 as a Tamper Zone:


329 - [1*1*] [*11*] [2*1*] [37] [1*1*] [*11*] [2*1*] [37]

Using PGM2 as a Panic Zone:


329 – [1*1*] [*11*] [2*1*] [2*1*] [1*1*] [*11*] [2*1*] [2*1*]

_________________________________________________________
Note 3:
When you are insetting the data which uses a [*] at the start and end of an entry, the
program will annunciate that the information has been correctly entered before you
enter the second [*]. You must still enter the 2nd [*].

Example 320 – 34 , 3*1 (keypad will beep) *, 3*1 (keypad will beep) *, 3 *1
(keypad will beep) *, 1*1 (keypad will beep) *, 37, # (keypad will “beep” “Beep”
beep”)