You are on page 1of 1

Allow for new plasterboard

ceiling with shadow gap


perimeter detail.

All wardrobe doors to be Painted plasterboard above


New timber framed double shopsprayed MDF with suitable doors. Refer to TCA Finishes
glazed window. Refer to TCA concealed, soft close hinges. Schedule for colours.
Window Schedule. All bathroom Allow for full height mirror
windows to be obscured/frosted. behind doors.
East Hampton marble
hexagonal mosaic tiles (Honed).
Allow for all walls to be Full height joinery to master Allow for all substrates as per
replastered and painted. Refer en-suite. manufacturers specifications
to TCA Finishes Schedule for and details.
colours.
Recesed shelf with timber Pocket door
frame, veneer finish and solid Allow for mirrored cupboards
Full height joinery to master lippings. above sinks with demister pads
and recessed handle detail to

2200
en-suite. Recessed handle details.
underside of doors.
Concealed LED strip light.
Drawers Drawers Drawers Toughened glass shower door
with circular cut out handle and
stainless steel / chrome patch
fittings. Majestic or similar Contractor to price for bespoke
Allow for 2no. cantilevered Drawers Drawers Drawers approved. 1400mm W matt white
timber drawers below sink.
shop-sprayed MR MDF vanity
with 2no. drawers. With corian /
Drawers Drawers Drawers high-MAC counter top
incorporating 2no. undermount
Allow for polished concrete
sinks, similar to below image.
screed floor. Skimcoat or similar
Elevation 1 Elevation 2 approved. Elevation 3
1 2 3

Flush mirror.

Marble recessed shelf Carerra Marble recessed shelf


and backsplash. Shelf on keko
push clips, to allow access to
cistern.
1500 x 900mm linear wet deck from
Concealed cistern flush plate
ccl-wetrooms, cut to size. Allow for full height
and wall hung cistern. Refer to
tanking to shower with end drain and Type S

1302
sanitaryware schedule.
stone infill grill, 8mm wide with tiles to match
floor. RIW Tilesafe and FWM membrane or Include for supply and
similar approved, installed to manufacturer's installation of all sanitaryware.
recommendations. Refer to TCA Sanitaryware
Schedule.
Contractor to specify number of traps
required to achieve suitable flow rate.

Elevation 4 Allow for tile finish to shower to finish flush Section AA Section 5
4 with floor - instalng support battens between 5 6
the joists with infill deck between the joists -
refer to floor type details.

5
4
GENERAL NOTES: A A
JOINERY:
Contractor to provide shop drawings for approval following site survey.
REFER TO FINISHES SCHEDULE, SKIRTING DRAWINGS AND DOOR SCHEDULE AND DETAILS.
Samples of proposed finishes to be provided for Architect's and Client approval prior to manufacture, and factored into tender
programme / timetable for all joinery items.
SANITARYWARE:
Generally, unless otherwise stated, all carcasses to be 18mm MDF and doors to be 25mm MDF. All MDF to be moisture resistant.
Refer to Architect's Sanitaryware Schedule. Dual fuel wall mounted towel
All veneered elements to be hard wood lipped and veneered over to avoid visible joints.
Allow for supply and installation of all sanitaryware and brassware throughout in accordance with radiator.
All timber elements to be shop finished using polyurethane varnish finish: matt (to protect the timber against wet coats etc.). All
architect's schedule. Include for all necessary brackets / fixings
shop sprayed finish to be: Morrells Compliant Two Pack Melamine Catalyst Lacquer, 20% sheen, ref 5203/590, colour tbc: shop
kits / back sets and all necessary concealed parts as recommended by manufacturers / suppliers.
spray applied in accordance with manufacturer's written instructions. Colours TBC prior to manufacture.
Compatibility of all specified items to be confirmed
Proposed specifications for all fixtures and fittings to be advised and a sample provided where possible for client approval prior to Polished concrete screed. 3
with suppliers prior to ordering. Allow for all necessary services connections and provisions, to all
orders being placed. All hinges, running gear, and other concealed fixings should be high quality. By Hafele or similar approved.
sanitaryware, brassware, appliances and white goods

1
Include for all internal fittings as indicated, all doors and drawers to be fitted with good quality concealed hinges or running gear, 2
throughout as required.
with soft closers to suit.
Note - all fittings to be installed to manufacturers recommendations.
Allow for polished chrome clothes hanging rails to be installed as indicated, by Hafele or similar approved. 30x25mm oval rail
All chinaware to be WHITE unless noted otherwise on schedule. All brassware to be SATIN CHROME
[801.19.220] with end supports to suit [803.33.723] and centre support as required [802.05.200] REFER TO TCA SANITARYWARE
unless noted otherwise on schedule. All silicon or mastic
Allow for push in shelf supports by Hettich or similar approved, ref. 0 016 181, and for adjustment holes to be drilled at equal SCHEDULE, FINISHES SCHEDULE, WALL
seals to match adjacent colour or finishes and to be confirmed with architects. TYPES, FLOOR TYPES AND DRAINAGE
spacing at approximate 100mm centres.
All pipework to be concealed, running in floor voids and ducts as indicated on drawings. Chase as LAYOUT DRAWINGS.
Allow for all necessary soft wood packers and scribe paanels as indicated on the drawings, or wherever necessary. To be painted
required.
out to match adjacent walls if visible.

152 x 152 x 30 UC Above


Allow here for all necessary cisterns to suit sanitaryware, including also for all necessary studwork boxing
Allow for mitred joints to visible edges unless otherwise indicated. Plan of First Floor Master En-suite
out and any necessary softwood supports to baths, sinks etc. as required. 7
Hafele - tel: 020 8551 8888 (www.hafele.co.uk)
Contractor to confirm with Architect and M+E Engineer the proposed water pressure value. All fixtures and
Hettich UK - tel: 0161 872 9552 (www.hettich.com)
fittings to comply with BREEAM water useage requirements.

ISSUED FOR TENDER

Rev Date Description Project


TIGG+COLL ARCHITECTS
By Chkd App THE COPYRIGHT DESIGN AND PATENTS ACT 1988 THIS DRAWING IS THIS COPYRIGHT OF
- 18.01.17 Issued for Tender PC DT TCA TIGG COLL ARCHITECTS LTD AND MUSTNOT BE COPIED OR REPRODUCED IN WHOLE OR 6 Northumberland Place, London, W2 5BS
PART, BY ANY METHOD WHATSOEVER, WITHOUT THE PRIOR WRITTEN APPROVAL OF
TIGG COLL ARCHITECTS LTD
FIRST FLOOR STUDIO Title
86-87 CAMPDEN STREET
LONDON, W8 7EN First Floor Master En-suite Internal Elevations
ALL SETTING OUT MUST BE CHECKED ONSITE
ALL LEVELS MUST BE CHECKED ONSITE E:INFO@TIGGCOLLARCHITECTS.COM
ALL DIMENSIONS MUST BE CHECKED ONSITE
DO NOT SCALE FROM THIS DRAWING T: 020 3170 6125 Date Scale [A3] 1:50 Drawing no. Rev.
THIS DRAWING MUST NOT BE USED ONSITE UNLESS ISSUED FOR CONSTRUCTION WWW.TIGGCOLLARCHITECTS.COM 18.01.17 Scale [A1] 1:25 265 - 811 -