You are on page 1of 25

Cat Electronic Technician 2017A v1.

0
Product Status Report

28/01/2018 08:36

Product Status Report


Parameter Value
Product ID YEE00638
Equipment ID NOT PROGRAMMED
Comments

Machine Control 345D (YEE00638)


Parameter Value
Product ID YEE00638
ECM Part Number 2218874-07
ECM Serial Number 01429135EM
Software Group Part Number 3386865-00
Software Group Release Date FEB2009
Software Group Description 345D HEX CONTROL
Active Diagnostic Codes Present No

Logged Diagnostic Codes [Diagnostic Clock = 9124 hours] - Machine Control 345D (YEE00638)
Code Description Occ. First Last
374- 5 Swing Brake Solenoid : Current Below Normal 3 9119 9119
581- 5 Power Shift Solenoid : Current Below Normal 3 9119 9119

Logged Event Codes [Diagnostic Clock = 9124 hours] - Machine Control 345D (YEE00638)
Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - Machine Control 345D (YEE00638)


Code Description
No Active
Diagnostic
Codes

Current Totals - Machine Control 345D (YEE00638)


Description Value Unit
Total Operating Hours 9125 hours
Engine Maintenance Hours 9123 hours
Engine Oil Hours 9123 hours
Engine Oil Filter Hours 9123 hours
Engine Coolant Hours 9123 hours
Fuel/ Water Separator Hours 9123 hours
Fuel Filter Hours 0 hours
Hydraulic Pump Hours 9123 hours
Hydraulic Pilot Oil Filter Hours 9123 hours
Hydraulic Case Drain Oil Filter 9123 hours
Hours
Return Hydraulic Oil Filter 9123 hours
Hours
Attachment Hydraulic Oil Filter 0 hours
Hours
Hydraulic Oil Hours 9123 hours
Final Drive Oil Hours 9123 hours
Swing Drive Oil Hours 9123 hours
Travel Motor Hours 1292 hours
Tool #1 Hours 0 hours
Tool #2 Hours 0 hours
Tool #3 Hours 0 hours
Tool #4 Hours 0 hours
Tool #5 Hours 0 hours
Tool #6 Hours 0 hours
Tool #7 Hours 0 hours
Tool #8 Hours 0 hours
Tool #9 Hours 0 hours
Tool #10 Hours 0 hours
Return Hydraulic Oil Filter 1.7 hours
Bypass Hours
Return Hydraulic Oil Filter 1.7 hours
Bypass at Cold Temperature
Hours
Hours of Operation at High 512.9 hours
Hydraulic Pressure
Hours of Operation at Relief 58.8 hours
Hydraulic Pressure

Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Product ID YEE00638
Main Pump Initial Maximum Working 48.0 %
Torque Percentage Configuration
Hydraulic Power Mode High
Power Management Mode Engine Speed High Speed
Limit Configuration
Fuel Economy Mode Enable Status Disabled
Economy Mode Disabled or Not Installed
Travel Alarm Installation Status Installed
Water Separator Level Switch Normally Closed (to Ground)
Configuration
Fuel Filter Differential Pressure Switch Not Installed
Config
Secondary Fuel Filter Differential Pressure Not Installed
Switch Config
Attachment Hydraulic Oil Filter Switch Not Installed
Configuration
Machine Overload Pressure Sensor Not Installed
Installation
Machine Overload Pressure Threshold Disabled or Not Installed kPa
Engine Fan Reversing Feature Installation Not Installed
Status
Engine Fan Reverse Operation Time Disabled or Not Installed sec
Heavy Lift System Installation Status Installed
Engine Cooling Fan Map High Ambient
Boom Low Pressure Relief System Not Installed
Installation Status
Quick Coupler Installation Status Unavailable
Quick Coupler Constant Engagement Unavailable
Pressure System Installation Status
Machine Application Configuration EAME Hammer
Main Pump Flow Limitation Pressure Installed
Solenoid Installation Status
Attachment Valve #1 Configuration F2 - One Way
Attachment Valve #3 Configuration Attachment Pump Valve - Two Way
Attachment Valve #4 Configuration Not Installed
Attachment Valve #1 Control Type Electrical
Configuration
Attachment Valve #3 Control Type Hydraulic
Configuration
Attachment Valve #4 Control Type Disabled or Not Installed
Configuration
Auxiliary Circuit Flow Combining Solenoid Not Installed
Installation Status
Variable Relief Valve #1 Configuration Not Installed
Variable Relief Valve #2 Configuration Not Installed
F2 Type Valve Load Sense Pres Sensor Not Installed
Installation
Left Attachment Pedal Installation Status Not Installed
Foot Switch Installation Status Not Installed
Joystick Handle Configuration Joystick Switch
Left Joystick Switch #1 Control Mode No valve controlled
Left Joystick Switch #2 Control Mode No valve controlled
Left Joystick Switch #4 Control Mode No valve controlled
Right Joystick Switch #1 Control Mode No valve controlled
Right Joystick Switch #2 Control Mode No valve controlled
Right Joystick Switch #4 Control Mode Momentary - Valve #1 Extend
Foot Switch Control Mode Disabled or Not Installed
Left Joystick Thumbwheel Control Mode Disabled or Not Installed
Right Joystick Thumbwheel Control Mode Disabled or Not Installed
Left Attachment Pedal Control Mode Disabled or Not Installed
Travel Speed Shift Low Delay 0.4 sec
Travel Speed Shift High Delay 0.4 sec
Travel Speed Shift Low Pres 18000 kPa
Travel Speed Shift High Pressure 32000 kPa
One Touch Engine Speed Setting 1100 rpm
AESC Setting 1300 rpm
AESC Delay Time 5.0 sec
Throttle Dial Position 1 Engine Speed 1000 rpm
Throttle Dial Position 2 Engine Speed 1100 rpm
Throttle Dial Position 3 Engine Speed 1200 rpm
Throttle Dial Position 4 Engine Speed 1300 rpm
Throttle Dial Position 5 Engine Speed 1470 rpm
Throttle Dial Position 6 Engine Speed 1590 rpm
Throttle Dial Position 7 Engine Speed 1700 rpm
Throttle Dial Position 8 Engine Speed 1800 rpm
Throttle Dial Position 9 Engine Speed 1900 rpm
Throttle Dial Position 10 Engine Speed 1980 rpm
Throttle Dial Position 1 Hydraulic System 25.0 %
Torque Percentage
Throttle Dial Position 2 Hydraulic System 40.0 %
Torque Percentage
Throttle Dial Position 3 Hydraulic System 61.0 %
Torque Percentage
Throttle Dial Position 4 Hydraulic System 69.0 %
Torque Percentage
Throttle Dial Position 5 Hydraulic System 78.0 %
Torque Percentage
Throttle Dial Position 6 Hydraulic System 84.0 %
Torque Percentage
Throttle Dial Position 7 Hydraulic System 84.0 %
Torque Percentage
Throttle Dial Position 8 Hydraulic System 84.0 %
Torque Percentage
Throttle Dial Position 9 Hydraulic System 92.0 %
Torque Percentage
Throttle Dial Position 10 Hydraulic System 100.0 %
Torque Percentage
Engine Oil Recommended Maintenance 500 hours
Interval
Engine Oil Filter Recommended 500 hours
Maintenance Interval
Engine Coolant Recommended 3000 hours
Maintenance Interval
Fuel/ Water Separator Recommended 500 hours
Maint Interval
Fuel Filter Recommended Maintenance 0 hours
Interval
Hydraulic Pilot Oil Filter Recommended 1000 hours
Maintenance Interval
Hydraulic Case Drain Oil Filter 1000 hours
Recommended MI
Return Hyd Oil Filter Recommended Maint 2000 hours
Interval
Attachment Hydraulic Oil Filter 0 hours
Recommended Maintenance Interval
Final Drive Oil Recommended 2000 hours
Maintenance Interval
Hydraulic Oil Recommended Maintenance 5000 hours
Interval
Swing Drive Oil Recommended 1000 hours
Maintenance Interval
Advanced Machine Security System Not Installed
Installation Status
Sunday Security System Bypass Start Disabled or Not Installed
Time
Sunday Security System Bypass Stop Time Disabled or Not Installed
Monday Security System Bypass Start Disabled or Not Installed
Time
Monday Security System Bypass Stop Disabled or Not Installed
Time
Tuesday Security System Bypass Start Disabled or Not Installed
Time
Tuesday Security System Bypass Stop Disabled or Not Installed
Time
Wednesday Security System Bypass Start Disabled or Not Installed
Time
Wednesday Security System Bypass Stop Disabled or Not Installed
Time
Thursday Security System Bypass Start Disabled or Not Installed
Time
Thursday Security System Bypass Stop Disabled or Not Installed
Time
Friday Security System Bypass Start Time Disabled or Not Installed
Friday Security System Bypass Stop Time Disabled or Not Installed
Saturday Security System Bypass Start Disabled or Not Installed
Time
Saturday Security System Bypass Stop Disabled or Not Installed
Time

Calibration Status - Machine Control 345D (YEE00638)


Calibration Status Last Successful Completion
Attachment Valve #1 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #1 Retract Not Calibrated Never Successfully Calibrated
Attachment Valve #2 Extend Failed Never Successfully Calibrated
Attachment Valve #2 Retract Failed Never Successfully Calibrated
Attachment Valve #3 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #3 Retract Not Calibrated Never Successfully Calibrated
Attachment Valve #4 Extend Not Calibrated Never Successfully Calibrated
Attachment Valve #4 Retract Not Calibrated Never Successfully Calibrated
Engine Cooling Fan Calibration Success 8609.5 hours
Engine Speed Calibration Success 0.4 hours
Left Joystick Thumbwheel Not Calibrated Never Successfully Calibrated
Calibration
Right Joystick Thumbwheel Not Calibrated Never Successfully Calibrated
Calibration
Left Attachment Pedal Not Calibrated Never Successfully Calibrated
Calibration
Right Attachment Pedal Not Calibrated Never Successfully Calibrated
Calibration
PRV - Attachment Valve #1 Not Calibrated Never Successfully Calibrated
Flow Limit
PRV - Combined Attachment Failed Never Successfully Calibrated
Valve Flow Limit
PRV - Combined Attachment Failed Never Successfully Calibrated
Valve Flow Limit
PRV - Pressure Gauge Not Calibrated Never Successfully Calibrated
PRV - Main Pump Flow Limit Success 0.6 hours
Calibration - Flow Meter
Method
PRV - Power Shift Pressure Success 0.4 hours
Calibration
Boom Cylinder Extend Pilot Not Calibrated Never Successfully Calibrated
Pressure Limit Solenoid Cal
Stick Cylinder Retract Pilot Not Calibrated Never Successfully Calibrated
Pressure Limit Solenoid Cal
PRV - Variable Relief Pressure Not Calibrated Never Successfully Calibrated
Calibration Solenoid 1
PRV - Variable Relief Pressure Not Calibrated Never Successfully Calibrated
Calibration Solenoid 2

Lifetime: Time vs Hydraulic Oil Temperature - Machine Control 345D (YEE00638)


Hydraulic Oil Temperature( Deg hours %
C)
<20 353.75 3.88
20-29 764.80 8.38
30-39 1020.45 11.18
40-49 1749.55 19.17
50-59 1785.15 19.56
60-69 2286.30 25.06
70-79 1060.40 11.62
80-89 100.30 1.10
90-99 4.30 0.05
100-109 0.00 0.00
110-119 0.00 0.00
>120 0.00 0.00

Lifetime: Time vs Unknown - Machine Control 345D (YEE00638)


Unknown( ) hours %
<20000 6782.60 74.33
20000-21999 719.70 7.89
22000-23999 572.80 6.28
24000-25999 382.55 4.19
26000-27999 239.85 2.63
28000-29999 159.85 1.75
30000-31999 129.55 1.42
32000-33999 102.40 1.12
34000-35999 27.65 0.30
36000-37999 4.70 0.05
38000-39999 0.90 0.01
>40000 2.35 0.03
Lifetime: Time vs Unknown - Machine Control 345D (YEE00638)
Unknown( ) hours %
<20000 7004.15 76.76
20000-21999 547.70 6.00
22000-23999 390.25 4.28
24000-25999 284.75 3.12
26000-27999 297.80 3.26
28000-29999 256.35 2.81
30000-31999 176.15 1.93
32000-33999 123.85 1.36
34000-35999 36.60 0.40
36000-37999 3.95 0.04
38000-39999 1.00 0.01
>40000 2.35 0.03

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name H130S
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 80.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 190 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name H140DS
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 80.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 200 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name H160DS
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 80.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 260 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction
Tool Configuration - Machine Control 345D (YEE00638)
Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

Tool Configuration - Machine Control 345D (YEE00638)


Description Value Unit
Tool Program Name 0
Maximum Throttle Dial 10
Minimum Throttle Dial Position 1
Underspeed Enable Enabled
Implement Priority Flow Mode Disabled or Not Installed
Enable Status
Hydraulic Temperature High 126.0 Deg C
Warning Event Threshold
Two Pump Flow Combine Disabled or Not Installed
Enable
Initial Tool Program Medium 5 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 50 %
Pressure Circuit Main Pump
Torque Reduction
One Way/ Two Way Valve Disabled or Not Installed
Mode
Variable Relief Valve #1 Disabled or Not Installed kPa
Pressure
Variable Relief Valve #2 Disabled or Not Installed kPa
Pressure
F2 Type Valve Max Flow Disabled or Not Installed kPa
Derate Pressure
F2 Type Valve Flow Derate Disabled or Not Installed kPa
Start Pressure
F2 Type Valve Flow Derate End Disabled or Not Installed kPa
Pressure
Multiple Operation Maximum 4000 kPa
Extend Pilot Pressure for
Attachment Valve #1
Multiple Operation Maximum Disabled or Not Installed kPa
Retract Pilot Pressure for
Attachment Valve #1
Attachment Valve #1 Flow 0 L/min
Setting
Attachment Valve #1 Multi- 0 L/min
Operation Additional Flow
Valve #1 Nominal Pressure 16000 kPa
Attachment Valve #1 Maximum 4000 kPa
Extend Pressure
Attachment Valve #1 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #1 Open 0.20 sec
Time
Attachment Valve #1 Close 0.20 sec
Time
Attachment Valve #1 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #3 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #3 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #3 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #3 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #3 Open Disabled or Not Installed sec
Time
Attachment Valve #3 Close Disabled or Not Installed sec
Time
Attachment Valve #3 Tool Flow Disabled or Not Installed
Direction
Attachment Valve #4 Flow Disabled or Not Installed L/min
Setting
Attachment Valve #4 Multi- Disabled or Not Installed L/min
Operation Additional Flow
Valve #4 Nominal Pressure Disabled or Not Installed kPa
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Extend Pressure
Attachment Valve #4 Maximum Disabled or Not Installed kPa
Retract Pressure
Attachment Valve #4 Open Disabled or Not Installed sec
Time
Attachment Valve #4 Close Disabled or Not Installed sec
Time
Attachment Valve #4 Tool Flow Disabled or Not Installed
Direction

C13 345C (MHX11826)


Parameter Value
Equipment ID NOT PROGRAMMED
Engine Serial Number MHX11826
ECM Part Number 2622879-01
ECM Serial Number 27606334JM
Personality Module Part Number 3135624-00
Personality Module Release Date MAY07
Personality Module Description C13-HEX-345D

Logged Diagnostic Codes [Diagnostic Clock = 9120.6695 hours] - C13 345C (MHX11826)
Code Description Occ. First Last
1785- 3 Intake Manifold Pressure Sensor : Voltage Above 3 9120 9120
Normal
274- 3 Atmospheric Pressure Sensor : Voltage Above 24 9106 9120
Normal
91- 8 Throttle Position Sensor : Abnormal Frequency, 5 9115 9118
Pulse Width, or Period
274- 4 Atmospheric Pressure Sensor : Voltage Below 1 9110 9110
Normal

Logged Event Codes [Diagnostic Clock = 9120.6695 hours] - C13 345C (MHX11826)
Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - C13 345C (MHX11826)


Code Description
274- 3 Atmospheric Pressure Sensor : Voltage Above Normal

Active Event Codes - C13 345C (MHX11826)


Code Description
No Active
Event Codes

Current Totals - C13 345C (MHX11826)


Description Value Unit
Engine Lifetime Hours Unavailable hours
Total Operating Hours 9121 hours
Total Fuel 265262 L
Engine Starts 4710
Lifetime Total Engine 873471720 rev
Revolutions
Total Idle Time 2104:18 hours
Total Idle Fuel 7826 L
Total Max Fuel 744044 L
Average Load Factor 34 %
Overall Load Factor 35 %

Configuration - C13 345C (MHX11826)


Description Value Unit
Equipment ID NOT PROGRAMMED
Engine Serial Number MHX11826
ECM Part Number 2622879-01
ECM Serial Number 27606334JM
Personality Module Part Number 3135624-00
Personality Module Release Date MAY07
Personality Module Description C13-HEX-345D
Rated Power 305 kW at 1800 rpm
Rated Peak Torque 1755 N-m at 1400 rpm
Test Spec 0K8247
Top Engine Speed Range 1980 - 1980 rpm
Ether Solenoid Configuration Continuous Flow Solenoid
FLS 34
FTS -41
Security System Immobilizer Installation Disabled or Not Installed
Status
Total Tattletale 0

Lifetime: Time vs Engine Coolant Temperature - C13 345C (MHX11826)


Engine Coolant Temperature( hours %
Deg C )
<50 224.65 2.47
50-54 61.50 0.68
55-59 85.20 0.94
60-64 153.05 1.69
65-69 209.70 2.31
70-74 446.55 4.92
75-79 2422.20 26.68
80-84 4718.25 51.96
85-89 685.35 7.55
90-94 65.30 0.72
95-99 7.85 0.09
100-104 0.80 0.01
105-109 0.00 0.00
110-114 0.00 0.00
115-119 0.00 0.00
>120 0.00 0.00

Lifetime: Time vs Inlet Air Temperature - C13 345C (MHX11826)


Inlet Air Temperature( Deg C ) hours %
<40 2717.55 84.29
40-44 390.85 12.12
45-49 102.45 3.18
50-54 12.10 0.38
55-59 0.85 0.03
60-64 0.05 0.00
65-69 0.05 0.00
70-74 0.00 0.00
75-79 0.00 0.00
80-84 0.00 0.00
85-89 0.00 0.00
90-94 0.00 0.00
95-99 0.00 0.00
>100 0.00 0.00

Lifetime: Time vs Boost Pressure - C13 345C (MHX11826)


Boost Pressure( kPa ) hours %
<80 991.15 30.74
80-89 446.20 13.84
90-99 556.55 17.26
100-109 563.80 17.49
110-119 472.95 14.67
120-129 119.60 3.71
130-139 59.10 1.83
140-149 8.60 0.27
150-159 4.80 0.15
160-169 1.10 0.03
170-179 0.00 0.00
180-189 0.00 0.00
190-199 0.00 0.00
>200 0.00 0.00

Lifetime: Time vs Engine Speed And Engine Load Factor - C13 345C (MHX11826)
rpm <1100 1100- 1300- 1500- 1700- 1900- 2100- >2300 Total
1299 1499 1699 1899 2099 2299
%
<50 1005.30 379.90 870.25 220.60 493.90 376.45 0.00 0.00 3346.40
50-60 0.05 0.10 1.80 13.70 189.75 64.20 0.00 0.00 269.60
60-70 0.00 0.15 1.70 10.45 146.95 57.40 0.00 0.00 216.65
70-80 0.00 0.00 0.55 10.20 138.65 69.55 0.00 0.00 218.95
80-90 0.00 0.00 0.15 5.10 344.95 143.50 0.00 0.00 493.70
>90 0.05 0.00 0.05 3.10 2432.85 926.50 0.00 0.00 3362.55
Total 1005.40 380.15 874.50 263.15 3747.05 1637.60 0.00 0.00 7907.85

Lifetime: Total Occurrences vs Engine Speed - C13 345C (MHX11826)


Engine Speed( rpm ) %
<2500 0.00 0.00
2500-2599 0.00 0.00
2600-2699 1.00 10.00
2700-2799 0.00 0.00
2800-2899 0.00 0.00
2900-2999 1.00 10.00
3000-3099 0.00 0.00
3100-3199 0.00 0.00
3200-3299 1.00 10.00
>3300 7.00 70.00

Injector Trim Calibration - C13 345C (MHX11826)


Injector Serial Number File Version
Injector1 000000005E0102758604 0
Injector2 000000005E010275882E 0
Injector3 000000005E0102759716 0
Injector4 000000005E010275920D 0
Injector5 000000005E0102760104 0
Injector6 000000005E010275930A 0

Monitor
Parameter Value
ECM Serial Number 109J2583AJ
Personality Module Part Number 3495410-00