Data Cables Catalog TEC Division

Cat 5e UTP Horizontal Cables, 100 MHz


4x2x24 AWG and 2x(4x2x24 AWG)

COMPLIANCE WITH
• ISO/IEC 11801:2002 Class D
• CENELEC EN 50173:2002
• ANSI/TIA/EIA-568-B.2
• IEC-60332-1
• UL 1581 VW-1
CABLE STANDARDS
• IEC 61156-5 Cat. 5e
• EN 50288-2-1

CONSTRUCTION

Conductor: 24 AWG bare copper


Insulation: Solid polyolefin. Nominal diameter over
insulation 0.93 mm
Pairs: Two wires twisted into pairs with
different lays (lay direction left)
Color code: Blue white-blue, orange white-orange,
green white-green and brown white-
brown
Cabling: 4 twisted pairs cabled
Outer jacket PVC or HFFR (LS0H)
HIGH FREQUENCY ELECTRICAL PROPERTIES
material:
Fig 8 Two cable with a connecting
construction: web forming a detachable cable pair. Mean characteristic Ω 100 ± 5
impedance (4-100 MHz)
Nom. Velocity of Propagation 0.67C
TRANSMISSION PROPERTIES Phase delay @ 100 MHz ns/100 m <536
Delay skew (4-100 MHz) ns/100 m <30

ELFEXT Return
Attenuation NEXT
Freq. pp Loss
dB/100m pp dB LOW FREQUENCY AND D.C. ELECTRICAL
MHz dB/100m dB PROPERTIES
Max. Min. Min. Min.
4 4.1 56 52 23.0
10 6.5 50 44 25.0
Mutual Capacitance @ 1 KHz nF/km 52
16 8.3 47 40 25.0
DC resistance Ω/km <95
20 9.3 46 38 25.0
Capacitance unbalance to ground pF/km <1500
31.25 11.7 43 34 23.6
Resistance unbalance % <2
62.5 17.0 38 28 21.5
Insulation resistance MΩ.m > 5000
100 22.0 35 24 20.1
Dielectric strength kV d.c./1min 1
PSNEXT=pair to pair NEXT-3
PSELFEXT=pair to pair ELFEXT-3
Operating voltage Volts 60
ACR=pair to pair NEXT-Attenuation [dB/100m]
PSACR=pair to pair ACR-3 [dB/100m]

Synergy Cables Ltd. E-Mail: export@synergy-cables.com Website: www.synergy-cables.com

Page 3
TEC Division Data Cables Catalog

Cat 5e UTP Horizontal Cables, 100 MHz


4x2x24 AWG and 2x(4x2x24 AWG)

ENVIRONMENTAL AND OTHER PROPERTIES MARKING


Cables are typically marked as follows
Operating temperature range °C -20 to +60
Synergy Cables SuperLan 5e, Part Number, UTP
Installation temperature range °C -5 to +50 4x2/24 AWG 100 MHz, PVC, IEC 61156-5 Cat. 5e,
Max installation tensile load kg 8 IEC 60332-1, RoHS, length in m
Min installation bend radius 12*cable OD
Min long term bend radius 8*cable OD or per customer request.
Flame retardancy (all cables) IEC 60332-1 ORDERING
UL-1581 VW-1
Halogen content (HFFR cables) IEC 60754-2 Consult the standard cable Part Numbers Table. Standard
packaging: 500 meters on a wooden drum. Other
Smoke emission (HFFR cables) IEC 61034
packaging options, constructions and materials may be
available. Please contact the Synergy Cables Marketing
Department.

Cable Part Numbers and Description

No. Caloric
Part Cable Wire Weight Dimension Jacket Jacket *
of Value
Number Geometry Gage kg/km mm Material RAL/color
Pairs MJoule/km
611277 Circular simplex 4 24 33 5.2 PVC 7032 Grey 480
611447 Circular simplex 4 24 34 5.2 HFFR 7032 Grey 390
604900 Fig. “8” duplex 8 24 67 5.4x11 PVC 7032 Grey 960
611450 Fig. “8” duplex 8 24 69 5.4x11 HFFR 7032 Grey 780

* Other jacket colors are available. Please specify.