You are on page 1of 3

Switch Alcatel OS6450-P24

=========================

Visualizar Configuración del Switch


===================================
show configuration snapshot
show configuration snapshot all

Visualizar Conexiones de Stack


==============================
show stack topology

Visualizar la MAC
=================
show mac-address-table

Visualiza VLAN
==============
show vlan

Visualizar Stack por Puerto


===========================
show stacking interfaces status

Apagar y encencer un puerto de red


===================================
interfaces 1/1 admin down
interfaces 1/1 admin up

verificar IP de Vlan
====================
show ip interface vlan <Numero de Vlan>

Acceso por SSH desde el Switch


=============================

ip service ssh
aaa authentication ssh local
Show ssh config

Visualiza Imagen del Switch


===========================

show microcode

Visualizar Direcciones IP Dhcp en el Switch


============================================

show dhcp-server leases

Configuración Dhcp en switch ingresar por WINSCP al directorio \flash\switch


============================================================================

#dhcp AP
#dhcp VLAN205

subnet 192.168.25.0 netmask 255.255.255.0


{
dynamic-dhcp range 192.168.25.100 192.168.25.254
{
option subnet-mask 255.255.255.0;
option domain-name-servers 8.8.8.8;
option routers 192.168.25.10;
option dhcp-lease-time 28800; #concesion por 8 horas
}
}

subnet 10.247.0.0 netmask 255.255.255.128


{
dynamic-dhcp range 10.247.0.40 10.247.0.44
{
option subnet-mask 255.255.255.128;
option domain-name-servers 8.8.8.8;
option routers 10.247.0.25;
option dhcp-lease-time 28800; #concesion por 8 horas
}
}
#dhcp VLAN6

subnet 192.168.6.0 netmask 255.255.255.0


{
dynamic-dhcp range 192.168.6.10 192.168.6.20
{
option subnet-mask 255.255.255.0;
option domain-name-servers 8.8.8.8;
option routers 192.168.6.1;
option dhcp-lease-time 28800; #concesion por 8 horas
}
}

#dhcp VLAN7

subnet 192.168.7.0 netmask 255.255.255.0


{
dynamic-dhcp range 192.168.7.10 192.168.7.20
{
option subnet-mask 255.255.255.0;
option domain-name-servers 8.8.8.8;
option routers 192.168.7.1;
option dhcp-lease-time 28800; #concesion por 8 horas
}
}

Guardar informacion del switch


==============================
copy certified working
write memory
copy working certified
Guardar informacion cuando el switch esta con stack
===================================================
write memory flash-shyncro

Verificar configuration de un punto de red en el switch


========================================================
show interfaces gigaethernet 1/25 status

Asignar VLAN a puerto de Switch


===============================
vlan 1 port default 1/24

Verificar IP de VLAN
=====================

show ip interface

Desactivar/Activar Spanning Tree en puerto


==========================================
vlan 255 stp disable
vlan 755 stp enable

Activar trunk en Switch


=======================
vlan 2 802.1q 1/24

Visualizar VLAN por puerto


==========================

show vlan port

Vericar el Gateway del switch


==========================

show ip route

You might also like