Professional Documents
Culture Documents
INSTALACIONES ELECTRICAS
AREA CONSTRUIDA
1ER. PISO = 112.52 m2
112.52
AREA LIBRE = 30 m2
CARGA
FD MD
INSTALADA
MD1 2000 100% 2000
813 35% 284.55
MD2 150 100% 150
MD3 1500 100% 1500
MD4 1500 100% 1500
MD5 8000 80% 6400
∆V< 2.5%(220v) K= 2
ρ = 0.0175
L= 4.2
∆V = 1.0983 volt.
CALCULO DEL FLUJO LUMINOSO TOTAL NECESARIO
POR AMBIENTES
Largo = 5 m
Ancho = 3.45 m
S = 17.25 m
2
h = 1.8 m
limpio = 0.8
sucio = 0.6
Cm = 0.8
6.- CALCULO DEL INDICE DEL LOCAL.
K = 1.13412
7.- FACTOR DE REFLEXION.
Techo = 0 0
Pared = 0 0
Suelo = 0 0
Cu = 0.30
Cu
limite inf. 1 0.28
limite sup. 1.2 0.31
valor 1.13412 0.300
Nancho = 1.74 ~ 2
Nlargo = 2.52 ~ 3
1.8
0.8
Subestaciones electricas al interior
alumbrado gener 200 B-C
alumbrado local 500 A-B
alumbrado de em 50 B-C
luminancia en calidad
servIcio (lux)
500 A-B
750 A-B
1000 A-B
300 B-C
500 A-B
1000 A-B
1000 A-B
1500 A-B
200 D-E
300 C-D
500 A-B
150 D-E
300 C-D
300 B-C
500 B-C
750 A-B
1000 A-B
50 D-E
200 D-E
300 D-E
500 A-B
Nivel de
AMBIENTES luminancia(l TIPO DE LUMINARIA
ux)
SALA COMEDOR 200 foco ahorrador en espiral de 65 watts
COCINA COMEDOR 300 foco ahorrador en espiral de 65 watts
RECEPCION DE ADMINISTARCION 100 foco ahorrador en espiral de 65 watts
ESTUDIO 300 foco ahorrador en espiral de 65 watts
2 DORMITORIOS 50 foco ahorrador en espiral de 65 watts
2 BAÑOS 100 foco ahorrador en espiral de 65 watts
PATIO INTERIOR 50 foco ahorrador LED de 50 watts
HALL 50 foco ahorrador en espiral de 65 watts
lumenes cantidad de
focos
3250 6
3250 3
3250 2
3250 2
3250 1
3250 1
1310 2
3250 5