Cálculo del Torque producido por el motor

P ≔ 150 W

W ≔ 2850 rpm
P
T≔―
W
T = 0.503 J

Torque disponible

De acuerdo al tipo de transmisión

n ≔ 0.9

Td ≔ n ⋅ T

Td = 0.452 J

Potencia suministrada por la bomba a la máquina

Ps ≔ Td ⋅ W

Ps = 135 W

Cálculo de caudal

N
γa ≔ 10000 ――
3
m
h≔1 m
Ps
Q ≔ ――
h ⋅ γa
3
m
Q = 0.014 ――
s

Cálculo del diametro de la tuberia

m
v≔8 ―
s
Q
A≔―
v
2
A = 0.002 m
‾‾
A
r≔ ―
π
r = 0.023 m
v
rrot ≔ ―
W

rrot = 26.805 mm

Longitud de la manguera
L ≔ π ⋅ rrot

L = 0.084 m

Perdidas Primarias

Datos del agua

kg
ρ ≔ 1000 ――
3
m

−3 s
u ≔ 1.102 ⋅ 10 N ⋅ ――
2
m

ρ⋅v⋅2⋅r
Re ≔ ―――
u

5
Re = 3.365 ⋅ 10

E ≔ 0.0015 mm
E
Er ≔ ――
2r

−5
Er = 3.236 ⋅ 10

−2
⎛ ⎛ Re ⎞⎞
f ≔ 1.42 ⋅ ⎜log ⎜――
⎝ ⎝ Er ⎟⎠⎟⎠

f = 0.014

m
g ≔ 9.81 ―
2
s
m
g ≔ 9.81 ―
2
s

2
L v
Hr ≔ f ⋅ ―― ⋅ ――
2 r 2⋅g

Hr = 0.084 m

Pérdidas primarias expresadas en potencia

Pper ≔ Hr ⋅ γa ⋅ Q

Pper = 11.322 W