Dear Mohammed,

Please find below our response to your email –

1. Testing method for welding portion –


a) Visual inspection of all the weld locations
b) Radiographic (X-ray) testing of random weld locations selected by the site engineer.

(Please refer to extract from AWS D1.4/D1.4M:2005 for details regarding weld inspection)

2. Details of coating material


 Fosroc Nitoprime Zincrich (See attached datasheet)

3. Bonding details for old and new concrete prior to avoid any cracks in the joint area.
 Fosroc Nitobond EP (See attached datasheet)

4. Concrete mix design


 Expanding concrete shall be used. Contractor shall select suitable admixture for this
purpose.