SERVICES

Steam Turbine Generator


Maintenance Programs
■■ Essential Steam Turbine Maintenance
A properly maintained Elliott steam turbine generator (STG) can operate reliably and efficiently
for decades. The best way to ensure the long-term performance of your Elliott STG is through
a collaborative maintenance agreement with Elliott Field Service. Downtime can be expensive
and unplanned downtime can be extremely disruptive. Following a regular maintenance
program is the only sure way to maximize system uptime and to detect potential problems
before they occur.
An effective STG maintenance program begins with specified preventive maintenance on
a periodic basis – daily, weekly, monthly, and annually. Facility operations and maintenance
personnel can perform many of these routine tasks. Regular inspections, necessary repairs
and overhauls should be performed by Elliott’s expert and experienced service engineers.
Elliott Field Service will tailor an ongoing maintenance agreement specifically to your system
and operating requirements to help you to achieve the STG operating performance you
require.

2
■■ Typical Maintenance Services
Elliott Field Service offers a variety of maintenance services to keep your STG operating
reliably and efficiently for years.

Remote Monitoring Major Overhauls


Remote condition monitoring allows Elliott A major overhaul is a detailed inspection
to see what you see. Elliott personnel can and overhaul of the entire steam turbine
monitor the operating conditions of the unit, generator set including the turbine casing,
trend operating data, set automatic alarm rotor, seals, and bearings; the generator;
and trends limits, and receive notifications and auxiliaries such as the gear, couplings,
through text and email when alarms or trips lubrication system and controls. An STG
occur. should be overhauled every 5 years.

Monthly and Semi-Annual Inspections Service Visits


Many STG operators elect to have an Elliott Elliott service engineers can be available for
service engineer onsite regularly to manage onsite repairs and maintenance in as little
less frequent preventive maintenance as 24 hours.
activities.
Training
Annual Inspections Elliott offers a variety of STG training
Annual inspections give Elliott service programs including online tutorials; onsite,
engineers the opportunity to observe hands-on training for operators; and formal
and evaluate STG performance onsite, classroom training at customer facilities and
discuss operating problems with operators, Elliott’s training center.
troubleshoot problems, review parts
inventory, and discuss training. An Elliott
service engineer should inspect an STG at
least once a year.

Bearing Inspections & Minor Overhauls


Steam turbine bearings and seals should
be physically inspected every two to three
years. This entails opening the bearing
housings; removing and inspecting the
bearings and seals; and replacing any
components as needed. The work is
generally done during a planned shutdown.

3
Recommended STG Maintenance

■■ Daily Maintenance ■■ Weekly Maintenance


❏ Monitor bearing housing oil levels ❏ Check for steam leaks
(on ring oiled setups); refill as needed

❏ Monitor and record: ■■ Monthly Maintenance


❍ Lube, seal, and control oil pressures ❏ Analyze turbine performance
and temperatures
❏ Exercise trip valve; does not require
❍ Bearing metal temperatures shutdown
❍ Bearing case or bearing oil throw off ❏ Sample lubricating oil; renew as
temperatures necessary
❍ Cooling water conditions ❏ Check for hunting
❍ Bearing housing vibration levels: ❏ Drain water and dirt from reservoir/
vertical & horizontal bearing housing; top off oil as needed
❍ 1st stage pressure (if applicable) ❏ Check instrument air & lube oil filters;
replace as needed
❍ Inlet steam pressure and temperature
at flanges ❏ Check generator ventilation openings,
air intake opening and its air filter
❍ Steam flow rates
(if applicable); clean or replace the
❍ Exhaust steam pressure and filter if necessary
temperature at flanges

❍ Governor valve/servo position(s)


❍ Speed
❍ Load
❍ Voltage
❍ Output kW
❍ Current
❏ Walk-around inspection for unusual
noises and leaks

❏ Review operating data for trends


❏ Check boiler feed-water chemistry

4
Recommended STG Maintenance

■■ Semi-Annual Inspection ❏ Visually inspect the turbine generator


string for:
❏ Send oil sample to lab for analysis
(if STG has gearbox) ❍ Evidence of steam, oil or water
leakage

❍ Evidence of steam deposits


■■ Annual Inspection
❍ Proper position of all valves
An annual inspection focuses on specific
sections of the STG in order to avoid ❍ Proper oil level
unplanned outages. The annual inspection
is also helpful for planning of minor and ❍ Condition of all control and trip
linkages
major overhauls.
❏ Visual inspection of seal and bearing ❍ Condition of instrumentation, conduit,
housings, and drain piping for wear, wiring, insulation, etc.
leaks, vibration, and plugged filters.
❏ Review the recorded of number of
Housings are not opened unless a normal starts and stops
potential problem is detected.
❏ Review the record of unit trip outs and
❏ Visual, mechanical, and electrical the reasons
inspection of all instrumentation,
protection, and control systems, ❏ Review the record of oil samples and
including trip assemblies conditioning

❏ Check safety devices ❏ Review the record of operating data:


pressure, temperatures, vibration, etc.
❏ Overspeed the turbine to check the
overspeed trip ❏ Discuss operating problems experienced
since last inspection or repair

❏ Grease generator earings (if applicable)


❏ Inspect spare parts inventory

5
Recommended STG Maintenance

■■ Bearing Inspection & Minor Overhaul


Turbine Scope of Work
❏ Shutdown equipment ❏ Hand lap the valve if signs of uneven
wear exist
❏ Lock Out Tag Out unit
❏ Replace the governor valve stem
❏ Visually inspect the turbine generator packing, if necessary
string for:
❏ Check governor valve setting; adjust
❍ Evidence of steam, oil or water open, closed and span, as necessary
leakage
❏ Check trip valve setting and linkage;
❍ Evidence of steam deposits adjust as necessary
❍ Proper position of all valves ❏ Check and clean water cooling chamber
(if applicable)
❍ Condition of all control and trip
linkages
❏ Clean and inspect trip valve for signs of
leakage
❍ Condition of instrumentation, conduit,
wiring, insulation, etc.
❏ Replace worn parts and hand lap if
necessary
❏ Measure and record turbine axial thrust
float and radial lift
❏ Check shaft alignment
❏ Disassemble and inspect turbine ❏ Remove and clean steam strainer. If
bearings for: strainer is exceptionally dirty, clean every
six months
❏ Visual condition of shaft journals
❏ Journal bearing clearance and condition
❏ Oil seal clearances Generator Scope of Work

❏ Condition of carbon rings or labyrinth ❏ Inspect winding and air filters for dirt,
seals; replace if necessary dust, oil, and salt vapor accumulation

❏ Visually inspect governor and trip valve ❏ Check insulation resistance of stator (and
rotor if synchronous generator); record
❏ Inspect governor valve and valve seat for and trend data
signs of leakage

6
Recommended STG Maintenance

■■ Major Overhaul
Turbine Scope of Work
❏ Perform same scope as bearing ❏ Inspect bearing sleeves, oil seals, and all
inspection and minor overhaul rotating components

❏ Remove upper half casing and record ❏ Inspect cage, laminations, stator core,
“as found” internal clearances slots, and all interior surfaces

❏ Remove rotor and perform visual ❏ Supervise cleaning of stator, rotor, or


inspection frame, as required

❏ Check condition of labyrinth seals; ❏ Perform generator electrical tests:


replace if necessary
❍ Ten-minute insulation resistance with
❏ Hand clean nozzle ring and visually polarization index, stator (and rotor for
inspect in position synchronous generator)

❏ Visually inspect reversing buckets & ❍ Winding copper resistance, stator and
diaphragms rotor

❏ Disassemble, inspect, and reassemble ❍ RTD resistance check, stator


main stop valve, if applicable
❍ AC impedance test, rotor
❏ Dimensional inspection of rotor journal ❍ Megger, stator and rotor
bearings and seal areas
❍ Insulation resistance and PI tests
❏ Check shaft alignment
❍ Current injection test with IR camera
❏ Drain oil reservoir and lube oil coolers (if induction generator)
❍ Inspect oil coolers ❍ Inspect & test exciter at a qualified
❍ Clean oil reservoir service shop; include the results in the
final report
❍ Refill oil reservoir
❏ Inspect generator coolers
❏ Install screens before bearing housings;
flush oil using system pumps and filters ❏ Install replacement bearings and other
parts, as required

❏ Remove, inspect, clean, and re-install


Generator Scope of Work WPII enclosure
❏ Disassemble generator end bells and ❏ Replace hardware, gaskets, cables, lugs,
remove field and other consumables, as required
❏ Hand clean and inspect stator and field ❏ Remove generator cooler ends and rod
out cooler tubes
❏ Inspect bearing journals for surface and
dimensional properties

7
Elliott Group is a global leader in the de-
sign, manufacture and service of tech-
nically advanced centrifugal compres-
sors, steam turbines, power recover
expanders and axial compressors used
in the petrochemical, refining, oil & gas
and process industries, as well as in
power applications. Elliott Group is a
wholly owned subsidiary of Ebara Cor-
poration, a major industrial conglomer-
ate headquartered in Tokyo, Japan.