2-106 Chapter 2 Troubleshooting

2.5 System Data/Component Code List


2.5 System Data/Component Code List
2.5.1 DC131 System Data List
<IIT>
Chain-Link Item Name Sub Initial Value Settings Range Changes Details
710-000 IIT/IPS Device Configuration IIT1 h'0101
710-002 Reserved IIT1
710-003 Reserved IIT1
710-004 Reserved IIT1
h'02: 76.2mm/s (2-pixel parallel output Sets the scan speed for 100% scan.
710-006 Scan Speed Settings (Image Sensor Selection) IIT1 h'02 Hex data
type) This setting is for the image sensor type that is installed.
710-010 Serial Number (5th digit: 10000 figure) IIT1 h'30 ("0") h'30 to h'39 ("0" to "9" in ASCII data) Hex data Sets the 5th digit of the serial number in ASCII data.
710-011 Serial Number (4th digit: 1000 figure) IIT1 h'30 ("0") h'30 to h'39 ("0" to "9" in ASCII data) Hex data Sets the 4th digit of the serial number in ASCII data.
710-012 Serial Number (3rd digit: 100 figure) IIT1 h'30 ("0") h'30 to h'39 ("0" to "9" in ASCII data) Hex data Sets the 3rd digit of the serial number in ASCII data.
710-013 Serial Number (2nd digit: 10 figure) IIT1 h'30 ("0") h'30 to h'39 ("0" to "9" in ASCII data) Hex data Sets the 2nd digit of the serial number in ASCII data.
710-014 Serial Number (1st digit: 1 figure) IIT1 h'30 ("0") h'30 to h'39 ("0" to "9" in ASCII data) Hex data Sets the 1st digit of the serial number in ASCII data.
Sets the last code of the serial number. The setting value is
710-015 Serial Number (Reserve: fixed to 0) IIT1 h'00 Fixed to h'00 Hex data
fixed to h'00.
Sets the magnification fine adjustment value in the Fast
Scan direction.
Fast Scan Magnification Fine Adjustment Uses the result of the magnification setting value multiplied
710-016 IIT1 0 -200 to +200 (-2.00 to +2.00%) 0.01%
Value (ASIC RE Settings) by the fine adjustment value for [ASIC IPS6W RE]
enlargement/reduction ratio setting.
Applied evenly across the ratio of 25% to 400%.
Sets the magnification fine adjustment value in the Slow
Scan direction.
Slow Scan Magnification Fine Adjustment Uses the result of the magnification setting value multiplied
710-018 IIT1 0 -200 to +200 (-2.00 to +2.00%) 0.01%
Value (ASIC RE Settings) by the fine adjustment value for [ASIC IPS6W RE]
enlargement/reduction ratio setting.
Applied evenly across the ratio of 25% to 400%.
Sets the magnification fine adjustment value in the Slow
Scan direction.
Slow Scan Magnification Fine Adjustment Uses the result of the main motor 1-pulse feed amount
710-020 IIT1 0 -200 to +200 (-2.00 to +2.00%) 0.01%
Value (Document Feed Speed) multiplied by the fine adjustment value as the main motor
1-pulse feed amount at 400% enlargement. (Currently Not
in Use)
Sets the side registration adjustment value.
710-022 Side Registration Adjustment Value IIT1 0 -127 to +127 dots 1 dot
The adjustment range is approx. ± 5.4mm.
Sets the detection range of registration sensors.
710-023 Registration Sensor Detection Range IIT1 0 0 to 255 pulses 1 pulse This value and the lead edge registration adjustment value
determine the tail edge registration adjustment value.
Chain-Link Item Name Sub Initial Value Settings Range Changes Details
Sets the top (lead edge) registration adjustment value.
710-024 Top Registration Adjustment Value IIT1 0 -240 to +240 pulses 1 pulse
The adjustment range is approx. ± 10.0mm.
Sets the 1-pulse feed amount of the main motor at 100%
36221 enlargement.
710-026 Main Motor 1-Pulse Feed Amount (at 100%) IIT1 0 to 65535 (0 to 0.065535mm) 0.000001mm
(0.036221mm) Used during enlargement/reduction by document feed and
document length measurement.
Image Sensor Black Scan Level Upper Limit
710-038 IIT1 1023
Determination Value
Dummy Setting Value for Image Sensor Black Sets the dummy values in upper limit determination used
710-040 IIT1 1023 0 to 1023
Scan Upper Limit Determination to overwrite the scan value during black shading.
Image Sensor White Scan Level Lower Limit
710-042 IIT1 0
Determination Value
Dummy Setting Value for Image Sensor White Sets the dummy values in lower limit determination used to
710-044 IIT1 0 0 to 1023
Scan Lower Limit Determination overwrite the scan value during white shading.
711-000 Image Sensor Invalid Pixel Settings IIT2 0
2700
711-002 IPS Process Pixel Settings IIT2
(21600 dots)
711-004 SI Pulse Width Settings IIT2 0
711-005 Scan Operation Settings for Half-Speed Mode IIT2 h'00
711-006 Image Sensor Output Data Logic Settings IIT2 h'01
711-007 Black Correction Value Retrieval Settings IIT2 h'01
711-008 White Correction Value Retrieval Settings IIT2 h'01
Use Black Correction Value at White
711-009 IIT2 h'01
Correction
Black Correction Value Calculation Method
711-010 IIT2 h'02
Settings
White Correction Value Calculation Method
711-011 IIT2 h'01
Settings
711-012 Number of Black Correction Value Retrievals IIT2 3
711-013 Number of White Correction Value Retrievals IIT2 3
White Reference Value (Coefficient of White
711-014 IIT2 h'03DE (990)
Correction LUT Calculation)
Image Sensor White Scan Error Level Lower
711-016 IIT2 h'0100 (256)
Limit
711-024 [ASIC SDC6W] Data Process Order Settings IIT2 h'00
711-025 [ASIC IPS6W] Data Process Order Settings IIT2 h'00
711-027 IPS Reset Timing IIT2 h'00
711-028 Image Sensor Lamp Brightness Stability Time IIT2 56 (0.56sec)
711-029 White Correction Sampling Interval IIT2 0
711-030 White Correction Execution Timing IIT2 h'01

2-107 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-108 Chapter 2 Troubleshooting
2.5 System Data/Component Code List
Chain-Link Item Name Sub Initial Value Settings Range Changes Details
The time taken from when the document was inserted until
the document is detected.
711-032 Document Insertion Detection Time IIT2 7 (0.7sec) 0 to 255 (0 to 25.5sec) 0.1sec
Pre-Feed starts when documents are detected to be
present continuously for the specified portion of time.
711-033 Reserved IIT2
Specifies the minimum time until the scan start is allowed
711-034 Minimum Scan Start Wait Time IIT2 15 (1.5 sec) 0 to 255 (0 to 25.5sec) 0.1sec
after Pre-Feed has been completed.
Sets the document feed speed at Pre-Feed in units of
711-035 Feed Speed at Pre-Feed IIT2 50 15 to 255mm/s 1mm/s 1mm/sec.
If the value is below 15, Feed is operated at 50mm/sec.
Sets the document feed speed at document output in units
711-036 Feed Speed at Document Output IIT2 76 15 to 255mm/s 1mm/s of 1mm/sec.
If the value is below 15, Feed is operated at 50mm/sec.
h'00: Allow detection Specify whether to allow/prohibit the left skew sensor to
711-037 Left Skew Sensor Detection Settings IIT2 h'00 Hex data
h'01: Prohibit detection detect a document skew.
711-038 Document Scan Length Limit Detection Setting IIT2 h'00
The time from when a document output has completed
until it was determined to be a continuous document feed.
The motor stops when this time has passed after output
711-039 Continuous Scan Wait Time IIT2 0 0 to 255 (0 to 25.5sec) 0.1sec
has completed.
If a subsequent document insertion is detected within this
time, no shading is performed.
711-040 Reserved IIT2
711-041 Reserved IIT2
h'00: Clear Jam when document is
removed
h'01: Clear Jam when document is
711-042 Jam Clear Method Settings IIT2 h'01 removed/cover closed is detected Hex data Specifies the document jam clear method.
(Ryoma sequence)
h'02: Clear Jam when cover closed is
detected (Kamatari sequence)
Specifies a limit value for standard document length check.
When the detected document length is longer than
Standard Document Length Determination 0: Prohibit limit determination
711-043 IIT2 30 1mm (standard document length + this setting value) it is
Limit Value 1 to 255: Limit value
determined to be Standard Document Length Over.
Note that no limit check is performed when 0 is specified.
h'00: Allow detection Specify whether to allow/prohibit detection of errors due to
711-044 Document Misload Detection Settings IIT2 h'00 Hex data
h'01: Prohibit detection misloading of documents.
711-056 Operation at USB Overflow IIT2 h'00
711-057 Response Type After USB Image Data Output IIT2 h'01
Chain-Link Item Name Sub Initial Value Settings Range Changes Details
Sets the transition time to power saving for a
single-scanner configuration.
Power Saving Transition Time in Single When the system receives no commands within the setting
711-064 IIT2 15 0 to 255 min. 1 min
Scanner Configuration time in Copy Mode, it enters the power saving mode.
The system returns from the power saving mode when it
receives any command.
711-065 Reserved IIT2
711-076 Log Output Mask Data IIT2 h'0117
712-000 S/W Boot Mode Version Info IIT3 h'0000
712-002 S/W User Mode Version Info IIT3 h'0000
712-004 IPS Data Version Info IIT3 h'0000
[ASIC SDC6W TRC] Register Setup Process
712-008 IIT3 h'00
Settings
[ASIC SDC6W DF] Register Setup Process
712-009 IIT3 h'00
Settings
[ASIC IPS6W BKG] Register Setup Process
712-010 IIT3 h'00
Settings
[ASIC IPS6W RE_1] Register Setup Process
712-011 IIT3 h'00
Settings
[ASIC IPS6W TRC] Register Setup Process
712-012 IIT3 h'00
Settings
[ASIC IPS6W DF] Register Setup Process
712-013 IIT3 h'00
Settings
[ASIC IPS6W SG_1] Register Setup Process
712-014 IIT3 h'00
Settings
Forced Operation Settings: Image Process
712-016 IIT3 h'00
Method
712-017 Forced Operation Settings: Negative Output IIT3 h'00
712-018 Forced Operation Settings: Mirror Image IIT3 h'00
712-019 Forced Operation Settings: Half-Speed Scan IIT3 h'00
Forced Operation Settings: Document Length
712-020 IIT3 h'00
Scan
712-021 Forced Operation Settings: Scan Options IIT3 h'00
713-000 Reserved IPS
713-001 Reserved IPS

2-109 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-110 Chapter 2 Troubleshooting
2.5 System Data/Component Code List
Chain-Link Item Name Sub Initial Value Settings Range Changes Details
Performs gamma correction of image output. 0.01 to
655.35
Can perform density adjustment of the images to be output
to the IOT. Consistent regardless of UI features, such as
0: Do not perform gamma correction document type, etc.
713-002 Output Gamma Correction IPS 0 (=100) 0.01 Example)
1 to 255 - Copy density is light → change to 1.1 to make it darker
- Copy density is dark → change to 0.9 to make it lighter
* However, note that this adjustment is common between
Copy/Scan image quality and individual adjustment is
impossible.
713-020 Contrast Text/Drawing IPS 0 Level You can increase/decrease the default value of contrast
(document mode type).
713-021 Contrast Text/Photo IPS 0 Level Example) The image with "normal" contrast can be
adjusted like:
0: Normal (= 3: default)
713-022 Contrast Printed Photo IPS 0 Level - if contrast is soft → 4
1: Softer (-2) to 5: Stronger (+2)
- if contrast is strong → 2
713-023 Contrast Photograph IPS 0 Level * However, note that this adjustment is common between
Copy/Scan image quality and individual adjustment is
713-024 Contrast Transparency IPS 0 Level
impossible.
713-026 Density Text/Drawing IPS 0 Level You can increase/decrease the default value of density
adjustment (document mode type).
713-027 Density Text/Photo IPS 0 Level Example) Image with "normal" density can be adjusted
like:
0: Normal (= 3: default)
713-028 Density Printed Photo IPS 0 Level - if it is light → 4
1: Lighter (-2) to 5: Darker (+2)
- if it is dark → 2
713-029 Density Photograph IPS 0 Level * However, note that this adjustment is common between
Copy/Scan image quality and individual adjustment is
713-030 Density Transparency IPS 0 Level
impossible.
When the background suppression is ON, the background
Density Limit with Background Suppression detection level can be set up to the upper limit of 255
713-032 IPS 210 Density density level. E.g. Used when you do not want to suppress
On: Text/Drawing
the background of high-density document (document
mode type).
Example) When background suppression is ON:
Density Limit with Background Suppression
713-033 IPS 210 0:White to 255:Black Density - Do not suppress the background of a dark document →
On: Text/Photo
150
- Suppress the background of a very dark document →
230
Density Limit with Background Suppression * However, note that this adjustment is common between
713-036 IPS 210 Density
On: Transparency Copy/Scan image quality and individual adjustment is
impossible.
Chain-Link Item Name Sub Initial Value Settings Range Changes Details
When background suppression is ON, the strength of
Threshold with Background Suppression On: background suppression can be specified (document
713-038 IPS 0 Level
Text/Drawing mode type).
Example) Image with "normal" density can be adjusted
Threshold with Background Suppression On: 0: Normal (= 3: default) like:
713-039 IPS 0 Level
Text/Photo 1: Lower (-2) to 5: Higher (+2) - Suppress the background → 4
- Do not suppress the background → 2
* However, note that this adjustment is common between
Threshold with Background Suppression On:
713-042 IPS 0 Level Copy/Scan image quality and individual adjustment is
Transparency
impossible.
Threshold with Background Suppression OFF: When background suppression is OFF, the strength of
713-044 IPS 0 Level
Text/Drawing background suppression can be specified (document
Threshold with Background Suppression Off: mode type).
713-045 IPS 0 Level
Text/Photo Example) Image with "normal" density can be adjusted
Threshold with Background Suppression Off: 0: Normal (= 3: default) like:
713-046 IPS 0 Level
Printed Photo 1: Lower (-2) to 5: Higher (+2) - Suppress the background → 4
Threshold with Background Suppression Off: - Do not suppress the background → 2
713-047 IPS 0 Level
Photograph * However, note that this adjustment is common between
Threshold with Background Suppression Off: Copy/Scan image quality and individual adjustment is
713-048 IPS 0 Level
Transparency impossible.
713-050 IPS Setting 1 Text/Drawing IPS 0 0 to 255 -
713-051 IPS Setting 1 Text/Photo IPS 0 0 to 255 -
713-054 IPS Setting 1 Transparency IPS 0 0 to 255 -
713-056 IPS Setting 2 Text/Drawing IPS 0 0 to 255 -
713-057 IPS Setting 2 Text/Photo IPS 0 0 to 255 -
713-058 IPS Setting 2 Printed Photo IPS 0 0 to 255 -
713-059 IPS Setting 2 Photograph IPS 0 0 to 255 -
713-060 IPS Setting 2 Transparency IPS 0 0 to 255 -
713-062 IPS Setting 3 Text/Drawing IPS 0 0 to 255 -
713-063 IPS Setting 3 Text/Photo IPS 0 0 to 255 -
713-064 IPS Setting 3 Printed Photo IPS 0 0 to 255 -
713-065 IPS Setting 3 Photograph IPS 0 0 to 255 -
713-066 IPS Setting 3 Transparency IPS 0 0 to 255 -

2-111 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-112 Chapter 2 Troubleshooting
2.5 System Data/Component Code List
<IOT>
Note The following table shows the data list for the IOT firmware V1.0.01.
When a new version of firmware is released in the future, the setting items and default values may be changed.
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-000 Reserved
910-001 Country Code System 1* 2* 1, 2 1 : NACO, 2 : EO *Prohibited to change the value
910-002 Billing Counter Type Settings System 2* 2* 2 : Area and Length *Prohibited to change the value
910-003 Length Counter Counting Unit Settings System 0* 0* 0, 1 0 : 1m, 1 : 0.1m *Prohibited to change the value
910-004 Roll 2 Connection Status System 0 0 0, 1 - 0: No, 1: Yes
910-006 Attention Light Connection Status System 0 0 0, 1 - 0: No, 1: Yes
910-008 Power Saving Cancel Settings at Drawer Open System 0 0 0, 1 - 0: Do not cancel, 1: Cancel
910-009 Max Additional Length/Plain Paper/36" System 0 0 0 to 1000 1mm
910-010 Max Additional Length/Plain Paper/A0, A1 System 0 0 0 to 1000 1mm
910-011 Max Additional Length/Plain Paper/A2, A3 System 0 0 0 to 1000 1mm
910-012 Max Additional Length/Tracing Paper System 0 0 0 to 1000 1mm
910-013 Max Additional Length/Transparency System 0 0 0 to 1000 1mm
910-014 Max Length Control Mode System 0 0
910-015 Reserved System 0 0
910-016 Reserved System 0 0
910-017 Reserved System 0 0
910-019 Reserved System 0 0
910-020 Reserved System 0 0
910-021 Reserved System 0 0
910-022 Attention Light Extended Function System 0 0 - Only for Japanese market.
0: Square Measures, 1: Converted for A4
910-023 Area Counter Type Settings System 0* 0* 0, 1 -
*Prohibited to change the value
910-101 Lead Edge Registration Adjustment Value/RFC/Plain Paper PH 0 0 -100 to 100 0.2mm
910-102 Lead Edge Registration Adjustment Value/RFC/Tracing Paper PH 0 0 -100 to 100 0.2mm
910-103 Lead Edge Registration Adjustment Value/RFC/Transparency PH 0 0 -100 to 100 0.2mm
910-107 Lead Edge Registration Adjustment Value/Bypass/Plain Paper PH 0 0 -100 to 100 0.2mm
910-108 Lead Edge Registration Adjustment Value/Bypass/Tracing Paper PH -2 -2 -100 to 100 0.2mm
910-109 Lead Edge Registration Adjustment Value/Bypass/Transparency PH -6 -6 -100 to 100 0.2mm
Added jam margin corresponding with the paper cut due to
910-110 Jam Margin Addition/Sensor when No Paper Detected PH 0 0 0 to 50 100ms
No Paper detection (Lead Edge jam)
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-112 Cut Length Adjustment Value/Roll 1/a/Plain Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-113 Cut Length Adjustment Value/Roll 1/a/Tracing Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-114 Cut Length Adjustment Value/Roll 1/a/Transparency RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-115 Cut Length Adjustment Value/Roll 1/b/Plain Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-116 Cut Length Adjustment Value/Roll 1/b/Tracing Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-117 Cut Length Adjustment Value/Roll 1/b/Transparency RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-118 Cut Length Adjustment Value/Roll 2/a/Plain Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-119 Cut Length Adjustment Value/Roll 2/a/Tracing Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-120 Cut Length Adjustment Value/Roll 2/a/Transparency RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-121 Cut Length Adjustment Value/Roll 2/b/Plain Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-122 Cut Length Adjustment Value/Roll 2/b/Tracing Paper RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Pulse number = {paper length - (28.9 + 0.2 x b)}/{502.7 +
910-123 Cut Length Adjustment Value/Roll 2/b/Transparency RFC 0 0 -99 to 99 1
0.1 x(a + cut length environment correction value)} x10000
Timing for creating a loop before cutting Roll 1
910-124 Cut Loop Speed Up Timing/Roll 1 RFC 93 93 50 to 200 1mm
Speed Up Start Timing = (paper length - this setting value)
Timing for creating a loop before cutting Roll 2
910-125 Cut Loop Speed Up Timing/Roll 2 RFC 93 93 50 to 200 1mm
Speed Up Start Timing = (paper length - this setting value)
910-126 Home Position Stop Timing RFC 61 61 0 to 200 10ms Paper Lead Edge Wait Position for Roll 1/2
910-127 Paper Stop Wait Time RFC 20 20 0 to 50 10ms Wait time until paper stops completely during cutting
Time used to determine whether Lead Edge cut was
910-128 RFC Blank Paper Output/Rest Time/Plain Paper RFC 6 6 1 to 300 10min
executed or not
Time used to determine whether Lead Edge cut was
910-129 RFC Blank Paper Output/Rest Time/Tracing Paper RFC 6 6 1 to 300 10min
executed or not
Time used to determine whether Lead Edge cut was
910-130 RFC Blank Paper Output/Rest Time/Transparency RFC 6 6 1 to 300 10min
executed or not
910-131 RFC Blank Paper Output/Output Sheets/Plain Paper RFC 0 0 0 to 10 1 sheet Number of sheets output for Lead Edge cutting
910-132 RFC Blank Paper Output/Output Sheets/Tracing Paper RFC 0 0 0 to 10 1 sheet Number of sheets output for Lead Edge cutting
910-133 RFC Blank Paper Output/Output Sheets/Transparency RFC 0 0 0 to 10 1 sheet Number of sheets output for Lead Edge cutting
The time since the Roll 1/2 Set Sensor is turned ON until
910-134 Feed Wait Time When Paper is Loaded RFC 7 7 0 to 20 100ms
Feed starts when paper is loaded.
Enable/disable RFC No Paper detection during printing
910-135 RFC No Paper Detection RFC 1 1 0, 1 -
0: Disable, 1: Enable

2-113 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-114 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
The time since the Roll 1/2 Feeder Motor is turned ON until
No Paper detection starts when the first sheet is fed
910-136 RFC No Paper Detection Start Timing/First Sheet RFC 20 20 0 to 100 100ms
Note that the unit of measurement is different for the
second and subsequent sheets.
The time since the Roll 2/2 Feeder Motor is turned ON until
No Paper detection starts when the second and
910-137 RFC No Paper Detection Start Timing/Second Sheet Onwards RFC 70 70 0 to 100 10ms subsequent sheets are fed
Note that the unit of measurement is different compared to
the first sheet.
910-138 RFC No Paper Detection Pulses RFC 0 0 0 to 10 1 pulse Number of pulses with which No paper is detected
910-139 RFC No Paper Detection Interval RFC 14 14 1 to 20 10ms Interval at which No Paper is detected
No Paper detection end delay time during cutting since
910-140 No Paper Detection End Timing RFC 0 0 0 to 50 10ms Feed stop instruction is issued until the paper completely
stopped.
Jam margin portion added immediately after feed (the time
910-141 RFC Jam Margin Addition/Immediately After Feed RFC 200 200 0 to 500 10ms
for slow up)
910-142 Inter-image for Paper/Roll 1 RFC 149 149 50 to 200 10ms The minimum inter-image time for Roll 1
910-143 Inter-image for Paper/Roll 2 RFC 149 149 50 to 200 10ms The minimum inter-image time for Roll 2
910-145 Inter-image for Paper/Bypass Bypass 150 150 50 to 200 10ms The minimum inter-image time for Bypass
The waiting time until the manual feed motor start after
910-147 Pre-feed Wait Timing (Bypass) Bypass 19 19 0~100 100ms
paper setting.
The time since Feed has started until remaining paper
910-148 RFC Remaining Paper Detection Count Start Timing RFC 50 50 0 to 70 10ms
detection pulse count starts.
Time taken to perform pulse count for remaining paper
910-149 RFC Remaining Paper Detection Interval RFC 150 150 10 to 200 10ms
detection
Number of pulses that is used by the pulse count of
910-150 RFC Remaining Paper Detection Pulses RFC 34 34 10 to 100 1 pulse remaining paper detection to determine that paper is
"getting low".
A temperature that is considered as high temperature
910-169 Cut Length Correction Temperature/High Temperature RFC 30 30 22 to 50 1°C when compared to the cut length environment correction
value.
A temperature that is considered as low temperature when
910-170 Cut Length Correction Temperature/Low Temperature RFC 16 16 0 to 21 1°C
compared to the cut length environment correction value.
The correction value to be added to the cut length
adjustment value (a) when temperature is determined to
910-171 Cut Length Environment Correction Value/High Temperature RFC 5 5 -99 to 99 1 be higher than the cut length correction temperature.
The cut length environment correction value is 0 at a
normal temperature.
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
The correction value to be added to the cut length
adjustment value (a) when temperature is determined to
910-172 Cut Length Environment Correction Value/Low Temperature RFC -8 -8 -99 to 99 1 be lower than the cut length correction temperature.
The cut length environment correction value is 0 at a
normal temperature.
The correction value of feed length (210mm) to be
910-173 RFC No Paper Rewind Feed Length Correction Value RFC 6 6 0 to 20 10mm
rewound (not cut) when No Paper is detected.
910-174 Motion Jam Detection Interval PH 5 5 1 to 15 100ms Stable time of the motion pulses that cause motion jam.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-201 BTR ON Timing XERO -5 -5 -50 to 50 10ms
Sensor (at Bypass feed) is turned ON until the BTR
Transfer Bias is switched.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-202 BTR OFF Timing XERO -10 -10 -50 to 50 10ms
Sensor (at Bypass feed) is turned OFF until the BTR Bias
between papers are switched.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-203 DTS H1 ON Timing XERO -20 -20 -150 to 50 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
turned ON.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-204 DTS L Switching Timing/Roll Paper/Plain Paper XERO 50 50 -50 to 350 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
switched to the DTS L.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-205 DTS L Switching Timing/Roll Paper/Tracing Paper XERO 50 50 -50 to 350 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
switched to the DTS L.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-206 DTS L Switching Timing/Roll Paper/Transparency XERO 50 50 -50 to 350 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
switched to the DTS L.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-207 DTS L Switching Timing/Cut Paper/Plain Paper XERO 50 50 -50 to 350 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
switched to the DTS L.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-208 DTS L Switching Timing/Cut Paper/Tracing Paper XERO 50 50 -50 to 350 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
switched to the DTS L.

2-115 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-116 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-209 DTS L Switching Timing/Cut Paper/Transparency XERO 50 50 -50 to 350 10ms
Sensor (at Bypass feed) is turned ON until the DTS H1 is
switched to the DTS L.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-210 DTS H2 Switching Timing/Roll Paper/Plain Paper XERO -33 -33 -150 to 100 10ms
Sensor (at Bypass feed) is turned OFF until the DTS L is
switched to the DTS H2.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-211 DTS H2 Switching Timing/Roll Paper/Tracing Paper XERO -33 -33 -150 to 100 10ms
Sensor (at Bypass feed) is turned OFF until the DTS L is
switched to the DTS H2.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-212 DTS H2 Switching Timing/Roll Paper/Transparency XERO -37 -37 -150 to 100 10ms
Sensor (at Bypass feed) is turned OFF until the DTS L is
switched to the DTS H2.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-213 DTS H2 Switching Timing/Cut Paper/Plain Paper XERO -33 -33 -150 to 100 10ms
Sensor (at Bypass feed) is turned OFF until the DTS L is
switched to the DTS H2.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-214 DTS H2 Switching Timing/Cut Paper/Tracing Paper XERO -33 -33 -150 to 100 10ms
Sensor (at Bypass feed) is turned OFF until the DTS L is
switched to the DTS H2.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-215 DTS H2 Switching Timing/Cut Paper/Transparency XERO -37 -37 -150 to 100 10ms
Sensor (at Bypass feed) is turned OFF until the DTS L is
switched to the DTS H2.
Adjustment time against the reference time since the Page
Sync Sensor (at RFC feed) or the Manual Page Sync
910-216 DTS INT Switching Timing XERO -10 -10 -50 to 150 10ms
Sensor (at Bypass feed) is turned OFF until the DTS H2 is
switched to the DTS INT.
Whether to perform LPH Duty control, BCR Environment
Temperature control, Deve Bias Density Environment
Image Control (Environment/Density Control) Switch Setting
910-217 Image 1 1 0, 1 - control, BTR Environment Switch control, and DTS
(LPH/BCR/Deve Bias/BTR/DTS)
Contamination control.
0: Disable, 1: Enable
Threshold value for BCR AC switch determination
910-218 BCR Temperature Determination Threshold Value XERO 0 to 30 1°C
temperature.
910-219 BCR AC/Normal Temperature XERO 15 15 70 to 380 0.01mA BCR AC current value at normal temperature BCR
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-220 BCR AC/Low Temperature XERO 150 150 70 to 380 0.01mA BCR AC current value at low temperature BCR
910-221 BCR DC XERO 170 170 206 to 644 -1V BCR DC voltage value BCR
438 to Deve
910-222 Deve Bias AC XERO 400 400 1V Deve Bias AC voltage value
1063 Bias
Deve
910-228 Deve Bias DC 1 XERO 300 300 50 to 550 -1V Deve Bias DC voltage value for "Light"
Bias
Deve
910-229 Deve Bias DC 2 XERO 300 300 50 to 550 -1V Deve Bias DC voltage value for "Lighter"
Bias
Deve
910-230 Deve Bias DC 3 XERO 300 300 50 to 550 -1V Deve Bias DC voltage value for "Normal"
Bias
Deve
910-231 Deve Bias DC 4 XERO 300 300 50 to 550 -1V Deve Bias DC voltage value for "Darker"
Bias
Deve
910-232 Deve Bias DC 5 XERO 300 300 50 to 550 -1V Deve Bias DC voltage value for "Dark"
Bias
910-235 DTS H1/A Zone/Roll Paper/Plain Paper XERO 250 250 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-236 DTS H1/A Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-237 DTS H1/A Zone/Roll Paper/Transparency XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-238 DTS H1/A Zone/Cut Paper/Plain Paper XERO 400 400 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-239 DTS H1/A Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 400 400 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-240 DTS H1/A Zone/Cut Paper/Transparency XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-241 DTS H1/B Zone/Roll Paper/Plain Paper XERO 270 270 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-242 DTS H1/B Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-243 DTS H1/B Zone/Roll Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-244 DTS H1/B Zone/Cut Paper/Plain Paper XERO 350 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-245 DTS H1/B Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 350 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-246 DTS H1/B Zone/Cut Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-247 DTS H1/C Zone/Roll Paper/Plain Paper XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-248 DTS H1/C Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-249 DTS H1/C Zone/Roll Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-250 DTS H1/C Zone/Cut Paper/Plain Paper XERO 350 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-251 DTS H1/C Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 350 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-252 DTS H1/C Zone/Cut Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-253 DTS L/A Zone/Roll Paper/Plain Paper XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-254 DTS L/A Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-255 DTS L/A Zone/Roll Paper/Transparency XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-256 DTS L/A Zone/Cut Paper/Plain Paper XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-257 DTS L/A Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-258 DTS L/A Zone/Cut Paper/Transparency XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-259 DTS L/B Zone/Roll Paper/Plain Paper XERO 250 250 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS

2-117 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-118 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-260 DTS L/B Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-261 DTS L/B Zone/Roll Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-262 DTS L/B Zone/Cut Paper/Plain Paper XERO 250 250 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-263 DTS L/B Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-264 DTS L/B Zone/Cut Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-265 DTS L/C Zone/Roll Paper/Plain Paper XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-266 DTS L/C Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-267 DTS L/C Zone/Roll Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-268 DTS L/C Zone/Cut Paper/Plain Paper XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-269 DTS L/C Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-270 DTS L/C Zone/Cut Paper/Transparency XERO 300 350 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-271 DTS H2/A Zone/Roll Paper/Plain Paper XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-272 DTS H2/A Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-273 DTS H2/A Zone/Roll Paper/Transparency XERO 220 220 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-274 DTS H2/A Zone/Cut Paper/Plain Paper XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-275 DTS H2/A Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-276 DTS H2/A Zone/Cut Paper/Transparency XERO 220 220 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-277 DTS H2/B Zone/Roll Paper/Plain Paper XERO 250 250 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-278 DTS H2/B Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-279 DTS H2/B Zone/Roll Paper/Transparency XERO 240 240 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-280 DTS H2/B Zone/Cut Paper/Plain Paper XERO 250 250 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-281 DTS H2/B Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-282 DTS H2/B Zone/Cut Paper/Transparency XERO 240 240 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-283 DTS H2/C Zone/Roll Paper/Plain Paper XERO 260 260 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-284 DTS H2/C Zone/Roll Paper/Tracing Paper/Slightly Heavy, Heavy XERO 260 260 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-285 DTS H2/C Zone/Roll Paper/Transparency XERO 250 250 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-286 DTS H2/C Zone/Cut Paper/Plain Paper XERO 260 260 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-287 DTS H2/C Zone/Cut Paper/Tracing Paper/Slightly Heavy, Heavy XERO 260 260 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-288 DTS H2/C Zone/Cut Paper/Transparency XERO 250 250 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-289 BTR Control Bias XERO 60 60 0 to 200 0.1μA Current value for BTR environment determination control BTR
910-290 BTR Bias Between Papers XERO 50 50 0 to 200 0.1μA Current value of the bias between papers for BTR BTR
910-291 BTR Cleaning Bias (-ve)/A Zone XERO 175 175 25 to 275 -10V Voltage value of BTR cleaning bias (-ve)
910-292 BTR Cleaning Bias (-ve)/B Zone XERO 160 160 25 to 275 -10V Voltage value of BTR cleaning bias (-ve)
910-293 BTR Cleaning Bias (-ve)/C Zone XERO 125 125 25 to 275 -10V Voltage value of BTR cleaning bias (-ve)
910-294 BTR Cleaning Bias (+ve)/A Zone XERO 120 120 0 to 450 0.1μA Current value of BTR cleaning bias (+ve)
910-295 BTR Cleaning Bias (+ve)/B Zone XERO 120 120 0 to 450 0.1μA Current value of BTR cleaning bias (+ve)
910-296 BTR Cleaning Bias (+ve)/C Zone XERO 120 120 0 to 450 0.1μA Current value of BTR cleaning bias (+ve)
910-297 BTR Transfer Bias/A Zone/Plain Paper/Large Size XERO 150 150 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-298 BTR Transfer Bias/A Zone/Plain Paper/Small Size XERO 150 150 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
BTR Transfer Bias/A Zone/Tracing Paper/Slightly Heavy,
910-299 XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Large Size
BTR Transfer Bias/A Zone/Tracing Paper/Slightly Heavy,
910-300 XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Small Size
BTR Transfer Bias/A Zone/Transparency/Normal, Slightly
910-301 XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Large Size
BTR Transfer Bias/A Zone/Transparency/Normal, Slightly
910-302 XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Small Size
910-303 BTR Transfer Bias/B Zone/Plain Paper/Large Size XERO 150 150 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-304 BTR Transfer Bias/B Zone/Plain Paper/Small Size XERO 150 150 0 to 450 0.1μA Current value of the BTR transfer bias BTR
BTR Transfer Bias/B Zone/Tracing Paper/Slightly Heavy,
910-305 XERO 160 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Large Size
BTR Transfer Bias/B Zone/Tracing Paper/Slightly Heavy,
910-306 XERO 160 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Small Size
BTR Transfer Bias/B Zone/Transparency/Normal, Slightly
910-307 XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Large Size
BTR Transfer Bias/B Zone/Transparency/Normal, Slightly
910-308 XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Small Size
910-309 BTR Transfer Bias/C Zone/Plain Paper/Large Size XERO 150 150 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-310 BTR Transfer Bias/C Zone/Plain Paper/Small Size XERO 150 150 0 to 450 0.1μA Current value of the BTR transfer bias BTR
BTR Transfer Bias/C Zone/Tracing Paper/Slightly Heavy,
910-311 XERO 160 160 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Large Size
BTR Transfer Bias/C Zone/Tracing Paper/Slightly Heavy,
910-312 XERO 160 160 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Small Size
BTR Transfer Bias/C Zone/Transparency/Normal, Slightly
910-313 XERO 110 110 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Large Size
BTR Transfer Bias/C Zone/Transparency/Normal, Slightly
910-314 XERO 110 110 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Heavy/Small Size
Interval for XERO test operation (number of non-working
910-315 Measure Against Bleed/Interval XERO 10 10 0 to 60 1 day days)
0: Prohibit test operation
910-316 Measure Against Bleed/Working Time XERO 60 60 3 to 180 1sec Working time for XERO test operation
Value to determine whether BTR resistance value is low or
910-321 A Zone Determination Value: X BTR 460 460 0 to 1650 1V
not
Value to determine whether BTR resistance value is high
910-322 C Zone Determination Value: Y BTR 820 820 0 to 1650 1V
or not
910-323 LPH1 POWER LPH 0 0 -50 to 50 1% LPH1 Light Density Error Correction
910-324 LPH2 POWER LPH 0 0 -50 to 50 1% LPH2 Light Density Error Correction
910-325 LPH3 POWER LPH 0 0 -50 to 50 1% LPH3 Light Density Error Correction

2-119 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-120 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-326 LPH DUTY/Default LPH 93 93 30 to 700 0.01% Brightness of the whole LPH
910-327 LPH DUTY/Light 2 LPH -20 -20 -90 to 90 1% Increased/decreased brightness against the default Duty
910-328 LPH DUTY/Light 1 LPH -10 -10 -90 to 90 1% Increased/decreased brightness against the default Duty
910-329 LPH DUTY/Dark 1 LPH 10 10 -90 to 90 1% Increased/decreased brightness against the default Duty
910-330 LPH DUTY/Dark 2 LPH 20 20 -90 to 90 1% Increased/decreased brightness against the default Duty
910-331 LPH DUTY/Exposure Up Ratio at Low Humidity/Plain Paper LPH 12 12 0 to 100 0.1%/% Increase in brightness ratio at low humidity
910-332 LPH DUTY/Low Humidity Switch Humidity LPH 55 55 0 to 100 1% The border humidity at which to increase brightness
The increase/decrease of Duty percentage when
910-333 LPH DUTY/Transparency (increasing/decreasing percentage) LPH -15 -15 -50 to 50 1% Transparency is selected (measure against FUSER
Offset)
910-334 LPH POWER/Brightness Up Percentage at Joint LPH 30 30 -30 to 30 1% Brightness of LPH joint dot
910-335 LPH POWER/Brightness Down Percentage at Joint LPH -30 -30 -30 to 30 1% Brightness of LPH joint dot
910-337 Left Image Shift Fast Scan LPH 0 0 -150 to 150 1/3 dot The shift amount of LPH1 image in the Fast Scan direction
910-338 Right Image Shift Fast Scan LPH 0 0 -150 to 150 1/3 dot The shift amount of LPH3 image in the Fast Scan direction
The shift amount of LPH2 image against LPH1in the slow
910-339 Center Image Shift Slow Scan LPH 0 0 -94 to 96 1/2 dot scan direction
Adjustment Range: ±2mm
The shift amount of LPH3 image against LPH1 and LPH2
910-340 Right Image Shift Slow Scan LPH 0 0 -48 to 48 1/2 dot in the slow scan direction
Adjustment Range: ±1mm
910-341 Roll 1 Side Registration Adjustment LPH 0 0 -30 to 30 8 dot Fast Scan direction shift amount at exposure start position
910-342 Roll 2 Side Registration Adjustment LPH 0 0 -30 to 30 8 dot Fast Scan direction shift amount at exposure start position
910-344 Bypass Side Registration Adjustment LPH 0 0 -30 to 30 8 dot Fast Scan direction shift amount at exposure start position
910-345 Lead Edge Erase/During Copy LPH 30 30 0 to 50 0.1mm Erased amount at Lead Edge of images
910-346 Tail Edge Erase/During Copy LPH 20 20 0 to 50 0.1mm Erased amount at Tail Edge of images
910-347 Both Edges Erase/During Copy LPH 6 6 0 to 50 8 dot Erased amount at both edges (sides) of images
910-348 Lead Edge Erase/During Plot LPH 30 30 0 to 50 0.1mm Erased amount at Lead Edge of images
910-349 Tail Edge Erase/During Plot LPH 20 20 0 to 50 0.1mm Erased amount at Tail Edge of images
910-350 Both Edges Erase/During Plot LPH 6 6 0 to 50 8 dot Erased amount at both edges (sides) of images
Specify whether to erase both edges (sides)
910-351 Image Erase Disabled/Both Edges/A0 Width LPH 0 0 0, 1 -
0: Erase enabled, 1: Erase disabled
Specify whether to erase both edges (sides)
910-352 Image Erase Disabled/Both Edges/A1 Width LPH 0 0 0, 1 -
0: Erase enabled, 1: Erase disabled
Specify whether to erase both edges (sides)
910-353 Image Erase Disabled/Both Edges/A2 Width LPH 0 0 0, 1 -
0: Erase enabled, 1: Erase disabled
Specify whether to erase both edges (sides)
910-354 Image Erase Disabled/Both Edges/A3 Width LPH 0 0 0, 1 -
0: Erase enabled, 1: Erase disabled
Specify whether to erase both edges (sides)
910-355 Image Erase Disabled/Both Edges/A4 Width LPH 0 0 0, 1 -
0: Erase enabled, 1: Erase disabled
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-356 Paper Tail Edge ROS OFF Margin/Shorter Than 1.5m LPH 0 0 -20 to 20 10ms Margin during ROS OFF with paper Tail Edge as reference
910-357 Paper Tail Edge ROS OFF Margin/1.5m or Longer LPH 0 0 -20 to 20 10ms Margin during ROS OFF with paper Tail Edge as reference
18K pixel count: Approx. 128m for A0 Portrait (image
910-363 Printable Length After Toner Empty Detection (Pixel Count) Toner 18 18 0 to 300 1K Count
density 3%)
Printable Length After Waste Toner Bottle Full Detection (Pixel 50K pixel count: Approx. 355m for A0 Portrait (image
910-364 Toner 50 50 0 to 300 1K Count
Count) density 3%)
910-365 Deve Bias DC Humidity Correction/Reference Value XERO 15 15 5 to 95 1% Reference humidity for humidity correction
-1000 to
910-366 Deve Bias DC Humidity Correction/Changed Amount XERO 35 35 0.01V Changed amount equivalent to 1% humidity
1000
910-367 Deve Bias DC Temperature Correction/Reference Value XERO 10 10 0 to 40 1°C Reference temperature for temperature correction
-1000 to
910-368 Deve Bias DC Temperature Correction/Changed Amount XERO 100 100 0.01V Changed amount equivalent to 1oC
1000
Logical value and timing correction value for the Manual
910-369 Manual Page Sync Sensor Timing Correction/Bypass XERO 0 0 -100 to 100 0.2mm
Page Sync Sensor
Logical value and timing correction value for the Page
910-370 Page Sync Sensor Timing Correction/RFC XERO 0 0 -100 to 100 0.2mm
Sync Sensor
DTS voltage value to be applied between papers after DTS
910-371 DTS INT/A Zone/Plain Paper XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-372 DTS INT/A Zone/Tracing Paper XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-373 DTS INT/A Zone/Transparency XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-374 DTS INT/B Zone/Plain Paper XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-375 DTS INT/B Zone/Tracing Paper XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-376 DTS INT/B Zone/Transparency XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-377 DTS INT/C Zone/Plain Paper XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-378 DTS INT/C Zone/Tracing Paper XERO 380 380 113 to 487 10V DTS
H2 output
DTS voltage value to be applied between papers after DTS
910-379 DTS INT/C Zone/Transparency XERO 380 380 113 to 487 10V DTS
H2 output
910-389 DTS H1/A Zone/Roll Paper/Tracing Paper/Normal XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-390 DTS H1/A Zone/Cut Paper/Tracing Paper/Normal XERO 400 400 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-391 DTS H1/B Zone/Roll Paper/Tracing Paper/Normal XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-392 DTS H1/B Zone/Cut Paper/Tracing Paper/Normal XERO 350 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-393 DTS H1/C Zone/Roll Paper/Tracing Paper/Normal XERO 300 300 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS

2-121 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-122 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-394 DTS H1/C Zone/Cut Paper/Tracing Paper/Normal XERO 350 350 113 to 487 10V DTS voltage value to be applied to the lead edge of paper DTS
910-395 DTS L/A Zone/Roll Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-396 DTS L/A Zone/Cut Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-397 DTS L/B Zone/Roll Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-398 DTS L/B Zone/Cut Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-399 DTS L/C Zone/Roll Paper/Tracing Paper/Normal XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-400 DTS L/C Zone/Cut Paper/Tracing Paper/Normal XERO 300 300 113 to 487 10V DTS voltage value to be applied to the middle of paper DTS
910-401 DTS H2/A Zone/Roll Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-402 DTS H2/A Zone/Cut Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-403 DTS H2/B Zone/Roll Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-404 DTS H2/B Zone/Cut Paper/Tracing Paper/Normal XERO 280 280 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-405 DTS H2/C Zone/Roll Paper/Tracing Paper/Normal XERO 260 260 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-406 DTS H2/C Zone/Cut Paper/Tracing Paper/Normal XERO 260 260 113 to 487 10V DTS voltage value to be applied to the tail edge of paper DTS
910-407 BTR Transfer Bias/A Zone/Tracing Paper/Normal/Large Size XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-408 BTR Transfer Bias/A Zone/Tracing Paper/Normal/Small Size XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-409 BTR Transfer Bias/B Zone/Tracing Paper/Normal/Large Size XERO 160 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-410 BTR Transfer Bias/B Zone/Tracing Paper/Normal/Small Size XERO 160 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-411 BTR Transfer Bias/C Zone/Tracing Paper/Normal/Large Size XERO 160 160 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-412 BTR Transfer Bias/C Zone/Tracing Paper/Normal/Small Size XERO 160 160 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Switch the determination criteria between Large and Small
size for selecting BTR transfer bias.
0: Small sizes are 350mm wide/A3 (12 inch) Roll width or
smaller. Otherwise, Large size.
910-413 BTR Transfer Bias/Small Size Determination Reference XERO 2 2 0, 1, 2 -
1: Small sizes are 500mm wide/A2 (18inch) Roll width or
smaller. Otherwise, Large size.
2: Small sizes are 670mm wide/A1 (24inch) Roll width or
smaller. Otherwise, Large size.
The increase/decrease of Duty percentage when Tracing
910-414 LPH DUTY/Tracing Paper (increasing/decreasing percentage) LPH 0 0 -50 to 50 1%
Paper is selected (measure against FUSER Offset)
The increase/decrease in Deve Bias DC value when
910-415 Deve Bias DC/Tracing Paper (increasing/decreasing value) XERO 0 0 -200 to 200 -1V Tracing Paper is selected
(measure against FUSER Offset)
The increase/decrease in Deve Bias DC value when
910-416 Deve Bias DC/Transparency (increasing/decreasing value) XERO 0 0 -200 to 200 -1V Transparency is selected
(measure against FUSER Offset)
910-417 BTR Transfer Bias/A Zone/Transparency/Heavy/Large Size XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-418 BTR Transfer Bias/A Zone/Transparency/Heavy/Small Size XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-419 BTR Transfer Bias/B Zone/Transparency/Heavy/Large Size XERO 130 130 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-420 BTR Transfer Bias/B Zone/Transparency/Heavy/Small Size XERO 130 240 0 to 450 0.1μA Current value of the BTR transfer bias BTR
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-421 BTR Transfer Bias/C Zone/Transparency/Heavy/Large Size XERO 110 110 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-422 BTR Transfer Bias/C Zone/Transparency/Heavy/Small Size XERO 110 110 0 to 450 0.1μA Current value of the BTR transfer bias BTR
910-423 LPH DUTY/Exposure Up Ratio at Low Humidity/Tracing Paper LPH 12 12 0 to 100 0.1%/% Increase in brightness ratio at low humidity
910-424 LPH DUTY/Exposure Up Ratio at Low Humidity/Transparency LPH 5 5 0 to 100 0.1%/% Increase in brightness ratio at low humidity
Fusing Temperature/Standard Room Temperature/Plain Paper/A0
910-478 Fuser 15 12 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Normal
Fusing Temperature/Standard Room Temperature/Plain Paper/A0
910-479 Fuser 19 15 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Plain Paper/A0
910-480 Fuser 19 16 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Heavy
Fusing Temperature/Standard Room Temperature/Plain Paper/A1
910-481 Fuser 15 12 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Normal
Fusing Temperature/Standard Room Temperature/Plain Paper/A1
910-482 Fuser 19 15 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Plain Paper/A1
910-483 Fuser 19 12 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Heavy
Fusing Temperature/Standard Room Temperature/Plain Paper/A2
910-484 Fuser 15 12 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Normal
Fusing Temperature/Standard Room Temperature/Plain Paper/A2
910-485 Fuser 19 15 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Plain Paper/A2
910-486 Fuser 19 12 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Side/Heavy
Fusing Temperature/Standard Room Temperature/Tracing
910-487 Fuser 15 9 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A0 Side/Normal
Fusing Temperature/Standard Room Temperature/Tracing
910-488 Fuser 17 11 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A0 Side/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Tracing
910-489 Fuser 19 13 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A0 Side/Heavy
Fusing Temperature/Standard Room Temperature/Tracing
910-490 Fuser 15 9 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A1 Side/Normal
Fusing Temperature/Standard Room Temperature/Tracing
910-491 Fuser 17 11 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A1 Side/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Tracing
910-492 Fuser 19 13 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A1 Side/Heavy
Fusing Temperature/Standard Room Temperature/Tracing
910-493 Fuser 15 9 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A2 Side/Normal
Fusing Temperature/Standard Room Temperature/Tracing
910-494 Fuser 17 11 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A2 Side/Slightly Heavy

2-123 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-124 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Fusing Temperature/Standard Room Temperature/Tracing
910-495 Fuser 19 13 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Paper/A2 Side/Heavy
Fusing Temperature/Standard Room
910-496 Fuser 16 6 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A0 Side/Normal
Fusing Temperature/Standard Room
910-497 Fuser 16 6 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A0 Side/Slightly Heavy
Fusing Temperature/Standard Room
910-498 Fuser 18 8 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A0 Side/Heavy
Fusing Temperature/Standard Room
910-499 Fuser 16 6 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A1 Side/Normal
Fusing Temperature/Standard Room
910-500 Fuser 16 6 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A1 Side/Slightly Heavy
Fusing Temperature/Standard Room
910-501 Fuser 18 8 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A1 Side/Heavy
Fusing Temperature/Standard Room
910-502 Fuser 16 6 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A2 Side/Normal
Fusing Temperature/Standard Room
910-503 Fuser 16 6 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A2 Side/Slightly Heavy
Fusing Temperature/Standard Room
910-504 Fuser 18 8 0 to 22 5°C Fuser fusing temperature = 90oC + (setting value x 5°C)
Temperature/Transparency/A2 Side/Heavy
Correction Coefficient/Low Room Temperature/Plain Paper/A0 Correction coefficient at low room temperature against
910-505 Fuser 10 10 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A0 Correction coefficient at low room temperature against
910-506 Fuser 10 15 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A0 Correction coefficient at low room temperature against
910-507 Fuser 10 15 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A1 Correction coefficient at low room temperature against
910-508 Fuser 10 10 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A1 Correction coefficient at low room temperature against
910-509 Fuser 10 15 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A1 Correction coefficient at low room temperature against
910-510 Fuser 10 10 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A2 Correction coefficient at low room temperature against
910-511 Fuser 10 10 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A2 Correction coefficient at low room temperature against
910-512 Fuser 10 15 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Paper/A2 Correction coefficient at low room temperature against
910-513 Fuser 10 10 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A0 Correction coefficient at low room temperature against
910-514 Fuser 10 20 0 to 30 -
Side/Normal Fuser fusing temperature
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Correction Coefficient/Low Room Temperature/Tracing Paper/A0 Correction coefficient at low room temperature against
910-515 Fuser 15 20 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A0 Correction coefficient at low room temperature against
910-516 Fuser 10 20 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A1 Correction coefficient at low room temperature against
910-517 Fuser 10 20 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A1 Correction coefficient at low room temperature against
910-518 Fuser 15 20 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A1 Correction coefficient at low room temperature against
910-519 Fuser 10 20 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A2 Correction coefficient at low room temperature against
910-520 Fuser 10 20 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A2 Correction coefficient at low room temperature against
910-521 Fuser 15 20 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Paper/A2 Correction coefficient at low room temperature against
910-522 Fuser 10 20 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A0 Correction coefficient at low room temperature against
910-523 Fuser 10 10 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A0 Correction coefficient at low room temperature against
910-524 Fuser 10 10 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A0 Correction coefficient at low room temperature against
910-525 Fuser 10 20 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A1 Correction coefficient at low room temperature against
910-526 Fuser 10 10 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A1 Correction coefficient at low room temperature against
910-527 Fuser 10 10 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A1 Correction coefficient at low room temperature against
910-528 Fuser 10 20 0 to 30 -
Side/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A2 Correction coefficient at low room temperature against
910-529 Fuser 10 10 0 to 30 -
Side/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A2 Correction coefficient at low room temperature against
910-530 Fuser 10 10 0 to 30 -
Side/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Transparency/A2 Correction coefficient at low room temperature against
910-531 Fuser 10 20 0 to 30 -
Side/Heavy Fuser fusing temperature
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-532 Fuser 28 28 0 to 28 5°C
Temperature/Plain Paper/Normal (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-533 Fuser 28 28 0 to 28 5°C
Temperature/Plain Paper/Slightly Heavy (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-534 Fuser 28 28 0 to 28 5°C
Temperature/Plain Paper/Heavy (setting value x 5°C)

2-125 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-126 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-535 Fuser 28 28 0 to 28 5°C
Temperature/Tracing Paper/Normal (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-536 Fuser 28 28 0 to 28 5°C
Temperature/Tracing Paper/Slightly Heavy (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-537 Fuser 28 28 0 to 28 5°C
Temperature/Tracing Paper/Heavy (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-538 Fuser 28 28 0 to 28 5°C
Temperature/Transparency/Normal (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-539 Fuser 28 28 0 to 28 5°C
Temperature/Transparency/Slightly Heavy (setting value x 5°C)
Warm Up Transition Temperature/High-Standard Room Warm Up Transition Temperature = fusing temperature -
910-540 Fuser 28 28 0 to 28 5°C
Temperature/Transparency/Heavy (setting value x 5°C)
Warm Up Transition Temperature/Low Room Temperature/Plain Warm Up Transition Temperature = fusing temperature -
910-541 Fuser 28 28 0 to 28 5°C
Paper/Normal (setting value x 5°C)
Warm Up Transition Temperature/Low Room Temperature/Plain Warm Up Transition Temperature = fusing temperature -
910-542 Fuser 28 28 0 to 28 5°C
Paper/Slightly Heavy (setting value x 5°C)
Warm Up Transition Temperature/Low Room Temperature/Plain Warm Up Transition Temperature = fusing temperature -
910-543 Fuser 28 28 0 to 28 5°C
Paper/Heavy (setting value x 5°C)
Warm Up Transition Temperature/Low Room Temperature/Tracing Warm Up Transition Temperature = fusing temperature -
910-544 Fuser 8 8 0 to 28 5°C
Paper/Normal (setting value x 5°C)
Warm Up Transition Temperature/Low Room Temperature/Tracing Warm Up Transition Temperature = fusing temperature -
910-545 Fuser 8 4 0 to 28 5°C
Paper/Slightly Heavy (setting value x 5°C)
Warm Up Transition Temperature/Low Room Temperature/Tracing Warm Up Transition Temperature = fusing temperature -
910-546 Fuser 8 4 0 to 28 5°C
Paper/Heavy (setting value x 5°C)
Warm Up Transition Temperature/Low Room Warm Up Transition Temperature = fusing temperature -
910-547 Fuser 28 28 0 to 28 5°C
Temperature/Transparency/Normal (setting value x 5°C)
Warm Up Transition Temperature/Low Room Warm Up Transition Temperature = fusing temperature -
910-548 Fuser 8 4 0 to 28 5°C
Temperature/Transparency/Slightly Heavy (setting value x 5°C)
Warm Up Transition Temperature/Low Room Warm Up Transition Temperature = fusing temperature -
910-549 Fuser 8 8 0 to 28 5°C
Temperature/Transparency/Heavy (setting value x 5°C)
Paper Weight to determine the standby temperature
910-551 Fuser Standby Temperature Setting/Paper Weight Fuser 1 1 0, 1, 2 -
0: Normal, 1: Slightly Heavy, 2: Heavy
910-552 Power Saving Mode Control Temperature Fuser 100 100 91 to 150 1°C Control temperature to be applied in Power Saving mode
The lower margin for determining when it is OK to accept a
JOB even when the heater temperature is lower than the
fusing temperature of the received JOB.
910-553 Fuser JOB Accept Temperature Fuser 5 5 1 to 50 1°C
(Except for the conditions in 910-560 and 910-561)
Fuser JOB Accept Temperature = control temperature -
(setting value x 1°C)
910-554 Hysteresis X/Low Temperature Control Fuser 28 28 0 to 50 1 step
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-555 Hysteresis Y/Low Temperature Control Fuser 40 40 1 to 100 1 step
910-556 Hysteresis X/Middle Temperature Control Fuser 4 4 0 to 20 1 step
910-557 Hysteresis Y/Middle Temperature Control Fuser 6 6 1 to 20 1 step
910-558 Hysteresis X/High Temperature Control Fuser 2 2 0 to 20 1 step
910-559 Hysteresis Y/High Temperature Control Fuser 3 3 1 to 20 1 step
The lower margin for determining when it is OK to accept a
JOB even when the heater temperature is lower than the
fusing temperature of the received JOB at standard or high
910-560 Fuser JOB Accept Temperature/Plain Paper/Normal Fuser 5 5 1 to 50 1°C
room temperature.
Fuser JOB Accept Temperature = control temperature -
(setting value x 1°C)
The lower margin for determining when it is OK to accept a
JOB even when the heater temperature is lower than the
fusing temperature of the received JOB at standard or high
910-561 Fuser JOB Accept Temperature/Plain Paper/Slightly Heavy Fuser 5 5 1 to 50 1°C
room temperature.
Fuser JOB Accept Temperature = control temperature -
(setting value x 1°C)
Fuser control temperature to select Hysteresis X/Low
910-566 Hysteresis/Lower Setting Temperature Fuser 140 140 100 to 150 1°C Temperature Control and Hysteresis Y/Low Temperature
Control.
Fuser control temperature to select Hysteresis X/High
910-567 Hysteresis/Higher Setting Temperature Fuser 190 190 170 to 240 1°C Temperature Control and Hysteresis Y/High Temperature
Control.
910-579 Fuser Motor Low Speed/A0 Width/Plain Paper Fuser 1 1 1 to 7 1 step
910-580 Fuser Motor Low Speed/A0 Width/Tracing Paper Fuser 1 1 1 to 7 1 step
910-581 Fuser Motor Low Speed/A0 Width/Transparency Fuser 2 2 1 to 7 1 step
910-582 Fuser Motor Low Speed/A1 Width/Plain Paper Fuser 1 1 1 to 7 1 step
910-583 Fuser Motor Low Speed/A1 Width/Tracing Paper Fuser 1 1 1 to 7 1 step
910-584 Fuser Motor Low Speed/A1 Width/Transparency Fuser 4 4 1 to 7 1 step
910-585 Fuser Motor Low Speed/A2 Width/Plain Paper Fuser 1 1 1 to 7 1 step
910-586 Fuser Motor Low Speed/A2Width/Tracing Paper Fuser 1 1 1 to 7 1 step
910-587 Fuser Motor Low Speed/A2Width/Transparency Fuser 4 4 1 to 7 1 step
910-588 Fuser Motor Low Speed/A3 Width or Smaller/Plain Paper Fuser 2 2 1 to 7 1 step
910-589 Fuser Motor Low Speed/A3 Width or Smaller/Tracing Paper Fuser 2 2 1 to 7 1 step
910-590 Fuser Motor Low Speed/A3 Width or Smaller/Transparency Fuser 5 5 1 to 7 1 step
910-591 Fuser Motor High Speed/A0 Width/Plain Paper Fuser 2 2 1 to 7 1 step
910-592 Fuser Motor High Speed/A0 Width/Tracing Paper Fuser 2 2 1 to 7 1 step
910-593 Fuser Motor High Speed/A0 Width/Transparency Fuser 4 4 1 to 7 1 step
910-594 Fuser Motor High Speed/A1 Width/Plain Paper Fuser 4 4 1 to 7 1 step

2-127 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-128 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
910-595 Fuser Motor High Speed/A1 Width/Tracing Paper Fuser 4 4 1 to 7 1 step
910-596 Fuser Motor High Speed/A1 Width/Transparency Fuser 6 6 1 to 7 1 step
910-597 Fuser Motor High Speed/A2 Width/Plain Paper Fuser 4 4 1 to 7 1 step
910-598 Fuser Motor High Speed/A2 Width/Tracing Paper Fuser 4 4 1 to 7 1 step
910-599 Fuser Motor High Speed/A2 Width/Transparency Fuser 6 6 1 to 7 1 step
910-600 Fuser Motor High Speed/A3 Width or Smaller/Plain Paper Fuser 6 6 1 to 7 1 step
910-601 Fuser Motor High Speed/A3 Width or Smaller/Tracing Paper Fuser 6 6 1 to 7 1 step
910-602 Fuser Motor High Speed/A3 Width or Smaller/Transparency Fuser 7 7 1 to 7 1 step
910-603 Paper Lead Edge High Time/A0 Width/Plain Paper Fuser 0 0 0 to 50 500ms Paper lead edge feed time at high speed
910-604 Paper Lead Edge High Time/A0 Width/Tracing Paper Fuser 18 18 0 to 50 500ms Paper lead edge feed time at high speed
910-605 Paper Lead Edge High Time/A0 Width/Transparency Fuser 18 18 0 to 50 500ms Paper lead edge feed time at high speed
910-606 Paper Lead Edge High Time/A1 Width/Plain Paper Fuser 0 0 0 to 50 500ms Paper lead edge feed time at high speed
910-607 Paper Lead Edge High Time/A1 Width/Tracing Paper Fuser 8 8 0 to 50 500ms Paper lead edge feed time at high speed
910-608 Paper Lead Edge High Time/A1 Width/Transparency Fuser 8 8 0 to 50 500ms Paper lead edge feed time at high speed
910-609 Paper Lead Edge High Time/A2 Width/Plain Paper Fuser 25 24 0 to 50 500ms Paper lead edge feed time at high speed
910-610 Paper Lead Edge High Time/A2 Width/Tracing Paper Fuser 25 24 0 to 50 500ms Paper lead edge feed time at high speed
910-611 Paper Lead Edge High Time/A2 Width/Transparency Fuser 25 24 0 to 50 500ms Paper lead edge feed time at high speed
910-612 Paper Lead Edge High Time/A3 Width or Smaller/Plain Paper Fuser 20 18 0 to 50 500ms Paper lead edge feed time at high speed
910-613 Paper Lead Edge High Time/A3 Width or Smaller/Tracing Paper Fuser 20 18 0 to 50 500ms Paper lead edge feed time at high speed
910-614 Paper Lead Edge High Time/A3 Width or Smaller/Transparency Fuser 20 18 0 to 50 500ms Paper lead edge feed time at high speed
Test operation time after Warm Up
910-615 Fuser Test Operation Settings/Test Operation Time After Warm Up Fuser 0 0 0 to 255 1sec
0: Prohibit test operation
Fuser Test Operation Settings/Test Operation Time Before Test operation time when paper is "slightly heavy" or
910-616 Fuser 0 0 0 to 120 30sec
Heavyweight Job "heavy"
910-617 Fuser Test Operation Settings/Test Operation Time During Wait Fuser 12 12 0 to 600 1sec Test operation time during standby
Fuser Test Operation Settings/Test Operation Start Interval During Time interval between test operations when standby status
910-618 Fuser 15 15 1 to 60 1 min
Wait continues
Time taken since control completion notification is issued
910-619 Fuser Exhaust Fan RH/LH Speed Switch Delay Time Fuser 1 to 1000 1sec until the Fuser Exhaust Fan RH/LH is switched to low
0 0 speed.
Temperature difference between the center and edge of
Wait Settings When Fuser Temperature Difference
910-622 Fuser 15 15 5 to 100 1°C the Heat Roll that executes test operation after small-size
Occurs/Temperature Difference Before Job Start
printing
Fusing Temperature/Standard Room Temperature/Plain
910-634 Fuser 15 14 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Paper/Center/Normal
Fusing Temperature/Standard Room Temperature/Plain
910-635 Fuser 19 17 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Paper/Center/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Plain
910-636 Fuser 19 18 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Paper/Center/Heavy
Initial Value Settings
Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Fusing Temperature/Standard Room Temperature/Tracing
910-637 Fuser 15 15 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Paper/Center/Normal
Fusing Temperature/Standard Room Temperature/Tracing
910-638 Fuser 17 17 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Paper/Center/Slightly Heavy
Fusing Temperature/Standard Room Temperature/Tracing
910-639 Fuser 19 19 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Paper/Center/Heavy
Fusing Temperature/Standard Room
910-640 Fuser 16 10 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Temperature/Transparency/Center/Normal
Fusing Temperature/Standard Room
910-641 Fuser 16 10 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Temperature/Transparency/Center/Slightly Heavy
Fusing Temperature/Standard Room
910-642 Fuser 18 14 0 to 22 5°C Fuser fusing temperature = 90°C + (setting value x 5°C)
Temperature/Transparency/Center/Heavy
Correction Coefficient/Low Room Temperature/Plain Correction coefficient at low room temperature against
910-643 Fuser 10 10 0 to 30 -
Paper/Center/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Correction coefficient at low room temperature against
910-644 Fuser 10 15 0 to 30 -
Paper/Center/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Plain Correction coefficient at low room temperature against
910-645 Fuser 10 15 0 to 30 -
Paper/Center/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Correction coefficient at low room temperature against
910-646 Fuser 10 20 0 to 30 -
Paper/Center/Normal Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Correction coefficient at low room temperature against
910-647 Fuser 15 20 0 to 30 -
Paper/Center/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Temperature/Tracing Correction coefficient at low room temperature against
910-648 Fuser 10 20 0 to 30 -
Paper/Center/Heavy Fuser fusing temperature
Correction Coefficient/Low Room Correction coefficient at low room temperature against
910-649 Fuser 10 25 0 to 30 -
Temperature/Transparency/Center/Normal Fuser fusing temperature
Correction Coefficient/Low Room Correction coefficient at low room temperature against
910-650 Fuser 10 25 0 to 30 -
Temperature/Transparency/Center/Slightly Heavy Fuser fusing temperature
Correction Coefficient/Low Room Correction coefficient at low room temperature against
910-651 Fuser 10 20 0 to 30 -
Temperature/Transparency/Center/Heavy Fuser fusing temperature
Correction coefficient for post-Warm Up test operation
Fuser Test Operation Settings/Correction Coefficient for Test
910-652 Fuser 90 30 0 to 255 1sec time when the environment temperature is lower than
Operation After Warm Up
20oC.
Long Paper Warm Up Transition Temperature Applied Length/Plain Printing length to which the long paper warm up transition
910-662 Fuser 510 510 21 to 2000 10mm
Paper/Normal temperature is applied
Long Paper Warm Up Transition Temperature Applied Length/Plain Printing length to which the long paper warm up transition
910-663 Fuser 510 510 21 to 2000 10mm
Paper/Slightly Heavy temperature is applied
Long Paper Warm Up Transition Temperature Applied Length/Plain Printing length to which the long paper warm up transition
910-664 Fuser 510 510 21 to 2000 10mm
Paper/Heavy temperature is applied

2-129 2.5 System Data/Component Code List


Chapter 2 Troubleshooting
2-130 Chapter 2 Troubleshooting
2.5 System Data/Component Code List

Initial Value Settings


Chain-Link Item Sub Changes Setting Data DC951
NASG XE Range
Long Paper Warm Up Transition Temperature Applied Printing length to which the long paper warm up transition
910-665 Fuser 260 260 21 to 2000 10mm
Length/Tracing Paper/Normal temperature is applied
Long Paper Warm Up Transition Temperature Applied Printing length to which the long paper warm up transition
910-666 Fuser 260 260 21 to 2000 10mm
Length/Tracing Paper/Slightly Heavy temperature is applied
Long Paper Warm Up Transition Temperature Applied Printing length to which the long paper warm up transition
910-667 Fuser 260 260 21 to 2000 10mm
Length/Tracing Paper/Heavy temperature is applied
Long Paper Warm Up Transition Temperature Applied Printing length to which the long paper warm up transition
910-668 Fuser 260 260 21 to 2000 10mm
Length/Transparency/Normal temperature is applied
Long Paper Warm Up Transition Temperature Applied Printing length to which the long paper warm up transition
910-669 Fuser 260 260 21 to 2000 10mm
Length/Transparency/Slightly Heavy temperature is applied
Long Paper Warm Up Transition Temperature Applied Printing length to which the long paper warm up transition
910-670 Fuser 260 260 21 to 2000 10mm
Length/Transparency/Heavy temperature is applied
910-701 Toner Empty Cancel Determination Printing Length Diag 10 10 10 1m
910-702 Printable Length After Waste Toner Bottle Full Cancel Diag 10 10 10 1m
910-753 USB Command Bulk Out Descriptor/End Point Number Driver 3 3 3, 4 -
910-754 USB Response Interrupt In Descriptor/End Point Number Driver 6 6 5, 6 -
910-755 USB Response Interrupt In Descriptor/Interrupt Interval Driver 8 8 6 to 14 -
910-756 USB Image Bulk Out Descriptor/End Point Number Driver 1 1 1, 2 -

<CP-Cont>

Setting
Chain-Link Item Category Initial Value Changes Setting Data Remarks
Range
700-000 Machine Config Info Common 1 1, 5 1: EP, 5: MF
700-005 Country Code Common - 1, 2 1 : NACO, 2 : EO
1, 2, 3, 4, 1: Japanese, 2: Chinese, 3: English (AP), 4: English
700-007 Language Code Common - 5, 6, 7, 8, (NACO), 5: English (EO), 6: French, 7: Italian,
9, 10 8: Garman, 9: Spanish, 10: Portuguese
720-004 Billing Selection Info System 0 Only for Japanese Market
850-000 EP-SV Connection ON/OFF EP-SV 0 Only for Japanese Market
850-001 EP-SV Phone Line Connection ON/OFF EP-SV 0 Only for Japanese Market
850-002 Closing Day Billing Data Display EP-SV 0 Only for Japanese Market
850-004 Optional Counter Notification to EP-SV EP-SV 0 Only for Japanese Market