1 4 5 6 7
37'-6" 24'-0" 30'-0" 30'-0" 30'-0" 30'-0"
22'-6 1/4" 1'-5 3/4"
KEYNOTE LEGEND
1'-6 1/2" WINDOW FILM TO ALIGN
WITH TOP OF CASEWORK NUMBER DESCRIPTION
3'-6" BACKSPLASH
2'-10 11/16"
2'-2" 74 PIPE BOLLARD
N1 R1
6'-0"
M6 76 OWNER FURNISHED EQUIPMENT
13'-1 11/16"
2
FEC
N1 M6 KINGSFORD/LITTER
14'-5 1/8"
M6 M4 80 MECHANICAL SHAFT, S.M.D.
11'-10"
PSO SPRAY F1 173 CLEAN
FD F1 168
TECHNOLOGY LAB F1 168A F1 168B
F1 171 384 SF 2
J5 CLOROX
4'-8"
4'-8"
277 SF 2
25'-1 9/16"
N1 R1
R1
NEW PLEASANTON CAMPUS
11'-2"
2 2 2
M6 STAIR 2
FEC
N7
33'-6"
6'-8"
6'-8"
10'-8 13/16" 2
F1 170
2
2 KINGSFORD/LITTER 2
BUILDING F
11'-11 7/8"
2 F1 172 285 SF DUST
2'-4" 12'-0"
11'-9"
9'-3" 2'-2" 3'-6" 3'-6" 3'-6" 5"
FD F1 167 8 1/4" TENANT IMPROVEMENTS
11 5/8"
KINGSFORD GRILL LAB F1 167A F1 167B
368 SF
10'-4" 2 2
F1 170
R1
F1 169
5060 JOHNSON DRIVE
5'-0 7/8"
11 5/8"
G4
845 SF R1
2'-8"
2'-8"
FEC
2 2 R1 R1
F1 171
F1 169
FEC FEC
F1 166
A.7 FEC 12'-9"
6'-0"
FEC 2 2 6'-7 1/16" R5 33'-1 11/16"
EQ
N7 11'-8 1/4"
5'-8"
6'-0"
FOR WALK OFF MATT W1
17'-11 7/8" 2 CORRIDOR 9'-8 3/4" FD 12'-0"
2
80 13'-9 7/8" 16'-2 1/8" 2 80
FS W1 F1 160
EQ
F1 130B W1
F1 144C
F1 140B
F1 142B
PARTITION PLAN GENERAL NOTES:
B
5'-5 7/8" 4'-10 9/16"
FEC
T: 415.243.4170
13'-0 3/8"
11'-6"
13'-2 1/2"
F1 141 F1 145
4'-3 1/8" FD 2. ALL NEW PARTITIONS ARE UNDERPINNED WITH BATT F: 415.243.4176
14'-3"
281 SF W2 INSULATION 4' EACH SIDE OF WALL ABOVE CEILING AND 19. ALL PARTITIONS THAT OCCUR ON EXTERIOR WINDOW
18'-11 1/4"
BLEND RAMP INTO F1 145 TO BE PRICED AS CONSTRUCTION U.N.O. SPECIFIC WALL MULLIONS ARE TO BE CENTERED ON THE MULLION U.N.O.
22 35
18'-10"
FLOOR SLOPE CONSTRUCTION TYPES ARE INDICATED ON THE WHEN NEW PARTITION INTERSECTS WINDOW MULLION,
PIPE BOLLARD TYP. A0801 ENSURE THAT ALL OPENINGS HAVE BEEN PROPERLY SEALED Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago
N6 5'-3 7/8" PARTITION PLAN ONLY. DO NOT USE OTHER THAN
BETWEEN ADJOINING SPACES. Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix
N6 PARTITION PLAN TO VERIFY PARTITION TYPES.
5'-5 7/8"
11"
A0801 4. GENERAL CONTRACTOR TO NOTIFY THE ARCHITECT OF 21. ANY EXISTING PARTITIONS ABUTTING PERIMETER MULLIONS
4'-6 15/16" 76 ANY DISCREPANCIES BETWEEN THE DRAWINGS AS SHOWN AND PERIMETER BUILDING COLUMNS SHALL BE REVIEWED
PAINTED STEEL AND THE EXISTING CONDITIONS FOR PROPER AND SEALED BETWEEN ADJOINING SPACES IF EXISTING SEAL
F1 140C
F1 140E
ANGLES COORDINATION PRIOR TO CONTINUING WITH WORK AS IS DEFICIENT OR DAMAGED.
(ANCHORED). SHOWN. 22. PROVIDE MISCELLANEOUS STEEL BACK-UP FRAMING AT
2 10" 10" 10" 76 10" 10"
FD 19'-6" 5. GENERAL CONTRACTOR SHALL BUILD OUT PARTITIONS TO LOCATIONS WHERE CABINETRY, SHELVING, HANDRAILS
TRENCH DRAIN TRENCH DRAIN ACCOMMODATE DEPTH REQUIRED BY FIRE EXTINGUISHER AND MISC. WALL HUNG EQUIPMENT ARE BEING
2 TRENCH DRAIN
EDGE OF CABINETS AND POWER PANELS, COORDINATE WITH FIRE SUPPORTED DIRECTLY FROM PARTITION.
DN 70ºF +/- 2º;
EDGE OF TRENCH EDGE OF PROTECTION DRAWINGS. 23. PROVIDE METAL BACKING FOR WALL MOUNTED PLASMA
WAREHOUSE 9 50%RH +/-5%
TRENCH DRAIN, TYP. TRENCH 6. GENERAL CONTRACTOR TO COORDINATE WITH SCREEN(S). REFER TO COMMUNICATION PLAN FOR LOCATION.
F1 130 A0802 KINGSFORD CONSTANT MILLWORKER AND MILLWORKER'S SHOP DRAWINGS ALL IN-
DRAIN, TYP. DRAIN, TYP. COORDINATE MOUNTING HEIGHT AND REQUIRED PLATE SIZE
1'-0 9/16"
1'-4" STOP MATERIALS TO MAINTAIN THE FIRE RATING 26. PROVIDE METAL BACKING FOR WALL MOUNTED WHITEBOARDS.
A7 2
11" 4'-0" CONTINUITY OF THE FLOOR CONSTRUCTION. MOUNT WITH BOTTOM EDGE @ 30" AFF. WHITE BOARD TO BE
9. G.C. TO IMPLEMENT REROUTING AND UPGRADING OF FURNISHED AND INSTALLED BY FURNITURE DEALER.
F1 142A
FEC
F1 140A
F1 144A
MECHANICAL SYSTEMS TO ACCOMMODATE NEW SYSTEM.
1'-0 9/16"
B.7 10. ALL DOOR OFFSETS TO BE 4" TO OPENING U.N.O.
27. EXISTING PERIMETER WINDOW WALL DRYWALL IS TO REMAIN.
2 10'-7 1/2" 2 8'-5 1/2" ACCESS HATCH ABOVE CT 9'-6 1/2" 6'-7" 7'-10" 12. DOORS WITHOUT DOOR TAGS ARE EXISTING TO REMAIN 28. ELECTRONIC DOOR HARDWARE SHALL BE LATCHING TYPE
2 ROOM CEILING ASSEMBLY. VALVE BOX, S.P.D. AND SHALL BE RETROFITTED WITH ACCESSIBLE DOOR (TO MAINTAIN UL RATING), AND SHALL ALLOW EGRESS
15'-1"
SEE SECOND FLOOR PLAN HARDWARE. WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE IN THE
2 4'-8 1/2"
FD EVENT OF A POWER FAILURE OR ACTIVATION OF EMERGENCY
26 74 13'-7" 2 13. ALL DOORS, NEW, EXISTING TO REMAIN OR RELOCATED
15'-0" 2
7'-4 9/16"
CORRIDOR FIRE ALARM SYSTEM; DOOR SHALL BE POSITIVELY LATCHED
A0801 15'-7 3/4" ARE TO BE ADA/IAC COMPLIANT. IF NOT ADJUST EXISTING DURING POWER FAILURE OR FIRE ALARM ACTIVATION.
W1 F1 132 HARDWARE, REPLACE WITH NEW COMPATIBLE HARDWARE LOCKING SYSTEM USED SHALL HAVE RECEIVED PRIOR Key Plan:
TO MATCH REMAINDER OF PROJECT. APPROVAL OF THE FIRE PREVENTION BUREAU.
F1 124B
F1 124A
F1 122A
80
14. ALL PARTITIONS SHOWN AS "ALIGNED" ARE TO BE SMOOTH
C 29. ALL PARTITION ASSEMBLIES TO COMPLY WITH SEISMIC
1'-7"
11"
C.1 15. EQUIPMENT PLATFORMS SHOWN ARE FOR CONCEPTUAL
1'-9 1/2"
2
EQUIPMENT LAYOUT ONLY AND ARE UNDER SEPARATE
VENT . S.P.D. W1 SUBMITTAL BY OWNER
16. ALL NEW APPLIANCES SHALL BE ENERGY STAR RATED.
A B
. . 17. NOT USED.
16'-6 15/16"
VENT . S.P.D.
TPP
PACKAGING & LEGEND:
F1 124
DYNAMICS LAB
F1 122
C N
FD 2887 SF W2
2563 SF
2'-2"
PROJECT
1'-0"
TRENCH DRAIN TRENCH DRAIN NORTH
NEW PARTITION - REFER TO
EDGE OF PROVIDE SOLID/OPAQUE WINDOW
A1001-A1002 FOR PARTITION
TRENCH FILM
EDGE OF SCHEDULE
SLOPE 1/4" / FT.
. .
73ºF +/- 4ºF;
60%RH +/- 5%
2 2 CORRUGATED
000
2'-7" 15'-9 1/2" CONDITIONING 2 NEW DOOR - REFER TO A1011
37'-1 3/4" 5'-9 1/2" 2 F1 123 9'-2"
W1 2 W1 FOR DOOR SCHEDULE
82 SF
G2
F1 124C
F1 122C
F1 122D
FEC
6 1/2"
2
D
4'-0 1/2"
FEC A0802 1 HOUR RATED PARTITION
7'-9 1/16" FEC
ELECTRICAL PANELS, S.E.D. 2 ELECTRICAL PANELS, S.E.D.
A7 8'-8 1/2" 5'-9 15/16" EQ EQ 4'-8" CORRIDOR
N1 2 8'-0" FD
2 14'-0" 6'-4"
A2
F1 110
2 HOUR RATED PARTITION
F1 119A
F1 115B
F1 115A
F1 116A
N2
FEC
N1 35 38 CMU PARTITION
A0801 A0801
W2
A2
ELECTRICAL ROOM 33
2 2 2 2
33'-6"
F1 116 A0801
CAPPED 2" IW, S.P.D. 2 ISSUED FOR CONSTRUCTION 04/27/2012
HALLWAY 378 SF CENTRAL PACKAGE LAB 8'-7" 12'-5" 12'-7"
4 7/8" N7 1 ADDENDUM 1 11/28/2011
F1 117
24'-9 3/8"
RECEIVING 182 SF
13'-3"
13'-2"
10'-0 13/16"
A7 IDF
F1 119 80 F1 118
F1 118
2423 SF M4
121 SF M4 M4
F1 116B
EQ
3'-7"
A2
A2 2
E
11"
M4
WAREHOUSE M6
F1 130
12'-11"
2
SHIPPING AND A0101C
18'-10 5/8"
2 RECEIVING
Drawing Title:
F1 119
be reproduced or utilized in any form, without prior
written authorization by The Cannon Corporation.
F1 119C
All rights reserved. No part of this document may
BUILDING F
2 1'-7 1/4" 17'-4" 3
LEVEL 01 FLOOR PLAN -
A0100C WEST
FEC
2
6'-6 7/8"
V1
4'-9"
M6 FEC
F1 180H 1/8" = 1'-0"
F
2
A0101A
© Cannon Design 2010