Professional Documents
Culture Documents
co
v ed
pro
a p
Un Sanitary Centrifugal Pumps
50Hz Curve Book
Table of Contents:
50 Hz Curves:
W+ 10/8 Model……………………………………………………………………8
W+ 22/20 Model………………………………………………………………..7-8
W+ 25/210 Model…………………………………………………………………9
W+ 30/80 Model……………………………………………………………...10-11
W+ 30/120 Model…………………………………………………………….12-13
W+ 35/35 Model……………………………………………………………...16-17
W+ 35/55 Model……………………………………………………………...18-19
W+ 50/8 Model……………………………………………………………….20-21
W+ 55/35 Model……………………………………………………………...22-23
W+ 55/60 Model……………………………………………………………...24-25
W+ 60/110 Model…………………………………………………………….26-27
W+ 65/350 Model…………………………………………………………….28-29
W+ 70/40 Model……………………………………………………………...30-31
W+ 80/80 Model……………………………………………………………...32-33
W+ 110/130 Model…………………………………………………………..34-35
W+ 140/50 Model…………………………………………………………….36-37
CANCELS W+SERIES
DATED
1-1-97
NOTE:
Provisional
ft
4.3"
40
3.9"
30 3.5"
20
10
0 5 10 15 20 25 30 35 40 45 50 55 USGPM
hp
4.3"
0.7
0.6
0.5 3.9"
0.4
3.5"
0.3
0.2
0.1
0 5 10 15 20 25 30 35 40 45 50 55 USGPM
ft
4.3"
2
0 5 10 15 20 25 30 35 40 45 50 55 USGPM
4
CANCELS W+SERIES
DATED 453402 ISS U 10.08
1-1-97
ft
18
5.6"
16 5.3"
5.1"
14
4.9"
12 4.7"
4.5"
4.3"
10
4.1"
8
0
0 10 20 30 40 50 60 USGPM
hp
0.30
5.6"
0.25
5.3"
0.20
5.1"
0.15
4.9"
4.7"
0.10 4.5"
4.3"
0.05 4.1"
0
0 10 20 30 40 50 60 USGPM
5
CANCELS W+SERIES
DATED 453402 ISS U 10.08
1-1-97
ft
75
5.6"
5.3"
60 5.1"
4.9"
4.7"
4.5"
45 4.3"
4.1"
30
15
0
0 20 40 60 80 100 120 USGPM
hp
2.4
5.6"
2.0
5.3"
1.6
5.1"
1.2
4.9"
4.7"
0.8
4.5"
4.3"
4.1"
0,4
0
0 20 40 60 80 100 120 USGPM
6
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
5.6"
%
20 5.1"
62
60
4.7"
55
15
4.3"
50
3.9"
10
3.7"
5 45
40
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 USGPM
hp
5.6"
0.4
5.1"
0.3
4.7"
0.2
4.3"
3.9"
3.7"
0.1
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 USGPM
ft
3.7" 5.6"
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 USGPM
7
CANCELS W+SERIES
DATED A-1-201.210 ISS T
1-1-97
EFFECTIVE 22-04-2010
ft
5.6"
90
%
80 5.1"
62
60
70 4.7"
55
60 4.3" 50
50 3.9"
40
3.7"
30
45
20
40
10
Pressure head
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 USGPM
hp
5.6"
3.5
5.1"
2.5
2 4.7"
1.5 4.3"
3.9"
1 3.7"
0.5
Power consumption
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 USGPM
ft
NPSH required 3.7" 5.6"
20
15
10 Inducer
5
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 USGPM
8
CANCELS W+SERIES
DATED A-1-201.215 ISS T
1-1-97
EFFECTIVE 23-04-2010
ft
11.4"
90 %
11.0"
80 10.6" 74
10.2"
70 70
9.8"
65
60 9.4"
62
9.1" 58
50
8.7"
8.3"
40
30
20
Pressure head
10
0 150 300 450 600 750 900 1050 1200 1350 USGPM
hp
11.4"
25
11.0"
20 10.6"
10.2"
15 9.8"
9.4"
9.1"
10
8.7"
8.3"
5
Power consumption
0
0 150 300 450 600 750 900 1050 1200 1350 USGPM
ft
NPSH required 11.4"
20
15
8.3"
10 Inducer
5
0
0 150 300 450 600 750 900 1050 1200 1350 USGPM
9
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
30 6.7"
%
6.3"
25 5.9"
78
5.5" 75
20 72
5.1" 70
65
15 4.7" 60
4.3"
10
0
0 50 100 150 200 250 300 USGPM
hp
6.7"
1.8
1.6 6.3"
1.4
5.9"
1.2
5.5"
1
0.8 5.1"
0.6 4.7"
4.3"
0.4
0.2
0
0 50 100 150 200 250 300 USGPM
ft
8 6.7"
6 4.3"
4
2
0
0 50 100 150 200 250 300 USGPM
10
CANCELS W+SERIES
DATED A-1-201.220 ISS T
1-1-08
EFFECTIVE 23-04-2010
ft
120 6.7"
6.3" %
100 5.9"
78
5.5" 75
80 72
5.1" 70
65
60 4.7" 60
4.3"
40
20
Pressure head
0
0 100 200 300 400 500 600 USGPM
hp
6.7"
14
5.9"
12
6.3"
10
5.5"
8
5.1"
6
4.7"
4 4.3"
2
Power consumption
0
0 100 200 300 400 500 600 USGPM
ft
NPSH required 6.7"
30
20 4.3"
10
Inducer
0
0 100 200 300 400 500 600 USGPM
11
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
6.9"
30
6.5" %
25 6.1"
76
5.7"
20
74
5.3"
70
15
65
10
60
5
0 50 100 150 200 250 300 USGPM
hp
6.9"
2
6.5"
1,5 6.1"
5.7"
1
5.3"
0,5
0
0 50 100 150 200 250 300 USGPM
ft
6.9"
6
4 5.3"
0
0 50 100 150 200 250 300 USGPM
12
CANCELS W+SERIES
DATED A-1-201.225 ISS T
1-1-97
EFFECTIVE 23-04-2010
ft
6.9"
%
120
6.5"
100 6.1"
76
5.7"
80 74
5.3"
70
60
65
40
60
Pressure head
20
0 100 200 300 400 500 600 USGPM
hp
6.9"
16
6.5"
6.1"
12
5.7"
8
5.3"
Power consumption
0
0 100 200 300 400 500 600 USGPM
ft
NPSH required 6.9"
20
5.3"
Inducer
10
0
0 100 200 300 400 500 600 USGPM
13
CANCELS W+SERIES
DATED 453402 ISS U 10.08
1-1-97
ft
30
6.9"
6.7"
6.5"
25 6.3"
6.1"
5.9"
20 5.7"
5.5"
5.3"
5.1"
15
10
0
0 10 20 30 40 50 60 70 80 90 USGPM
hp
0.7
6.9"
0.6 6.7"
6.5"
0.5
6.3"
0.4
6.1"
5.9"
0.3
5.7"
5.5"
0.2 5.3"
5.1"
0.1
0
0 10 20 30 40 50 60 70 80 90 USGPM
14
CANCELS W+SERIES
DATED 453402 ISS U 10.08
1-1-97
ft
120
6.9"
6.7"
6.5"
100 6.3"
6.1"
5.9"
80 5.7"
5.5"
5.3"
5.1"
60
40
20
0
0 20 40 60 80 100 120 140 160 180 USGPM
hp
5.5
6.9"
5.0
6.7"
6.5"
4.0
6.3"
3.0 6.1"
5.9"
5.7"
2.0
5.5"
5.3"
5.1"
1.0
0
0 20 40 60 80 100 120 140 160 180 USGPM
15
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
6.9"
%
30 6.5"
6.1" 70
25 68
5.7" 65
5.3"
20
4.9"
60
15
55
50
10
5
0 10 20 30 40 50 60 70 80 90 100 110 USGPM
hp
6.9"
1
6.5"
0.8
6.1"
0.6
5.7"
5.3"
0.4 4.9"
0.2
0
0 10 20 30 40 50 60 70 80 90 100 110 USGPM
ft
6.9"
4
4.9"
3
2
1
0 10 20 30 40 50 60 70 80 90 100 110 USGPM
16
CANCELS W+SERIES
DATED A-1-201.230 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
6.9"
6.5"
120
η%
6.1" 70
100 68
5.7"
65
5.3"
80
4.9"
60
60
55
Pressure head
50
40
0 25 50 75 100 125 150 175 200 225 USGPM
hp
Power consumption 6.9"
8
7
6.5"
6
6.1"
5
5.7"
4
5.3"
3 4.9"
1
0 25 50 75 100 125 150 175 200 225 USGPM
ft
NPSH required
20 6.9"
4.9"
10 Inducer
0
0 25 50 75 100 125 150 175 200 225 USGPM
17
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
60 65 70
35 7.1" 74 76
%
6.7"
30
6.3"
25 5.9"
5.5"
20 5.1"
4.7"
15
10
0
0 20 40 60 80 100 120 140 160 180 USGPM
hp
7.1"
1.4
6.7"
1.2
6.3"
1
5.9"
0.8
5.5"
0.6 5.1"
4.7"
0.4
0.2
0
0 20 40 60 80 100 120 140 160 180 USGPM
ft
4.7" 7.1"
5
4
3
2
1
0 20 40 60 80 100 120 140 160 180 USGPM
18
CANCELS W+SERIES
DATED A-1-201.235 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
140 7.1"
6.7" η%
120
6.3"
76
100 5.9"
74
5.5"
80 5.1" 70
4.7" 65
60
60
40
Pressure head
20
0 50 100 150 200 250 300 350 USGPM
hp
12 7.1"
10 6.7"
6.3"
8
5.9"
6 5.5"
5.1"
4
4.7"
Power consumption
0
0 50 100 150 200 250 300 350 USGPM
ft
NPSH required 7.1"
4.7"
20
15
10 Inducer
5
0
0 50 100 150 200 250 300 350 USGPM
19
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
7.9" 20 25 30 35
38
40
45 7.5"
%
40 7.1"
6.7"
35
6.3"
30 5.9"
5.5"
25
20
15
0 5 10 15 20 25 30 35 USGPM
hp
0.9
0.8 7.9"
0.7 7.5"
7.1"
0.6
6.7"
0.5
6.3"
0.4 5.9"
5.5"
0.3
0.2
0.1
0
0 5 10 15 20 25 30 35 USGPM
ft
7.9"
1.4
5.5"
1
0.6
0.2
0 5 10 15 20 25 30 35 USGPM
20
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
20 25 30 35
190 7.9" 38 40 %
7.5"
170
7.1"
150 6.7"
130 6.3"
5.9"
110 5.5"
90
70
50
0 10 20 30 40 50 60 70 USGPM
hp
7
7.9"
6
7.5"
5 7.1"
6.7"
4
6.3"
5.9"
3 5.5"
0
0 10 20 30 40 50 60 70 USGPM
ft
7.9"
6
5.5"
4
0
0 10 20 30 40 50 60 70 USGPM
21
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
8.3"
50
7.9"
45
7.5"
40
7.1"
35
6.7"
30 6.3"
45 50 55 60 62
25 64
64
% 62
20
0 10 20 30 40 50 60 70 80 90 100 110 USGPM
hp
8.3"
1.8
1.6
7.9"
1.4
7.5"
1.2
7.1"
1
6.7"
0.8 6.3"
0.6
0.4
0.2
0
0 10 20 30 40 50 60 70 80 90 100 110 USGPM
ft
5 6.3" 8.3"
4
3
2
1
0
0 10 20 30 40 50 60 70 80 90 100 110 USGPM
22
CANCELS W+SERIES
DATED A-1-201.245 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
210 8.3"
200
190 7.9"
180
170 7.5"
160
150 7.1"
140
6.7"
130
120 6.3"
110 45 50 55 60 62 64
100
η%
90 Pressure head
80
0 25 50 75 100 125 150 175 200 225 USGPM
hp
8.3"
14
12 7.9"
7.5"
10
7.1"
8 6.7"
6 6.3"
2
Power consumption
0
0 25 50 75 100 125 150 175 200 225 USGPM
ft
NPSH required 6.3"
20 8.3"
10
Inducer
0
0 25 50 75 100 125 150 175 200 225 USGPM
23
CANCELS W+SERIES
DATED A-1-201.250 ISS S
1-1-97 PAGE 1 of 4
EFFECTIVE 1-11-08
ft
8.7" 55 60
8.3" 65 h%
50
70
7.9"
45 70
72
7.5"
40
7.1" 65
35
6.7"
30 6.3"
25
20
15
Pressure head
10
0 20 40 60 80 100 120 140 160 180 200 220 240 USGPM
hp
8.7"
3 8.3"
7.9"
2.5
7.5"
2 7.1"
1.5 6.7"
6.3"
1
0.5
Power consumption
0
0 20 40 60 80 100 120 140 160 180 200 220 240 USGPM
ft
NPSH required 6.3" 8.7"
4
3
2
1
0
0 20 40 60 80 100 120 140 160 180 200 220 240 USGPM
24
CANCELS W+SERIES
DATED A-1-201.250 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
55 60
8.7"
65 η%
200 8.3"
8.3" 70
7.9"
180 70
7.9"
7.5"
160
7.5"
7.1" 65
140 7.1"
6.7"
120 6.7"
6.3"
6.3"
100
80
Pressure head
60
0 50 100 150 200 250 300 350 400 450 500 USGPM
hp
8.7"
25
8.3"
20 7.9"
7.5"
15 7.1"
6.7"
10 6.3"
Power consumption
0
0 50 100 150 200 250 300 350 400 450 500 USGPM
ft
NPSH required 6.3" 8.7"
15
10
5 Inducer
0
0 50 100 150 200 250 300 350 400 450 500 USGPM
25
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
9.1" 60
60 65 68
8.7" 70
72 %
73
8.3"
50
73
7.9" 72
74 70
7.5" 68
40
7.1"
6.7"
30 6.3"
20
10
0 50 100 150 200 250 300 350 400 USGPM
hp
9.1"
5 8.7"
8.3"
4
7.9"
7.5"
3
7.1"
6.7"
2 6.3"
0
0 50 100 150 200 250 300 350 400 USGPM
ft
9.1"
8 6.3"
6
4
2
0
0 50 100 150 200 250 300 350 400 USGPM
26
CANCELS W+SERIES
DATED A-1-201.255 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
9.1" 60 65
68
70
220 8.7" 72
73 η%
8.3" 73
190
72
7.9" 74 70
160 68
7.5"
7.1"
130
6.7"
100 6.3"
70
Pressure head
40
0 100 200 300 400 500 600 700 USGPM
hp
9.1"
40 8.7"
8.3"
30 7.9"
7.5"
7.1"
20
6.7"
6.3"
10
Power consumption
0
0 100 200 300 400 500 600 700 USGPM
ft
NPSH required 9.1"
6.3"
30
20
10 Inducer
0
0 100 200 300 400 500 600 700 USGPM
27
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
10.2" 60 65
70
62.5 9.8" 75
78 %
9.4"
9.1"
50 8.7"
8.3"
37.5 7.9"
7.5"
25
12.5
0
0 100 200 300 400 500 600 700 800 900 1000 USGPM
hp
12.5 10.2"
9.8"
9.4"
10
9.1"
8.7"
7.5
8.3"
7.9"
5 7.5"
2.5
0
0 100 200 300 400 500 600 700 800 900 1000 USGPM
ft
7.5"
7.5
10.2"
5
2.5
0
0 100 200 300 400 500 600 700 800 900 1000 USGPM
28
CANCELS W+SERIES
DATED A-1-201.260 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
10.2" 60 65
280 70
9.8" 75
78 η%
240 9.4"
9.1"
200 8.7"
8.3"
160 7.9"
7.5"
120
80
Pressure head
40
0 200 400 600 800 1000 1200 1400 1600 1800 USGPM
hp
10.2"
100
9.8"
90
9.4"
80 9.1"
70 8.7"
60 8.3"
50 7.9"
40 7.5"
30
20
Power consumption
10
0 200 400 600 800 1000 1200 1400 1600 1800 USGPM
ft
7.5"
NPSH required
30 10.2"
20
Inducer
10
0
0 200 400 600 800 1000 1200 1400 1600 1800 USGPM
29
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
9.4"
65
9.1"
60
8.7"
55
8.3"
50
7.9"
45
7.5"
40 40 45 50 52
54 55
35
%
30
0 10 20 30 40 50 60 70 80 90 USGPM
hp
9.4"
9.1"
2
8.7"
8.3"
1.5
7.9"
7.5"
1
0.5
0
0 10 20 30 40 50 60 70 80 90 USGPM
ft
7.5" 9.4"
3
0
0 10 20 30 40 50 60 70 80 90 USGPM
30
CANCELS W+SERIES
DATED A-1-201.265 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
9.4"
260
9.1"
240
8.7"
220
8.3"
200
7.9"
180
7.5"
160 40 45 50 52
54 55
140
η%
Pressure head
120
0 20 40 60 80 100 120 140 160 180 USGPM
hp
Power consumption
9.4"
20
9.1"
15 8.7"
8.3"
7.9"
10 7.5"
0
0 20 40 60 80 100 120 140 160 180 USGPM
ft
NPSH required 7.5" 9.4"
10
5 Inducer
0
0 20 40 60 80 100 120 140 160 180 USGPM
31
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
10.0" 50 55 %
75 60 62
63 64
70 9.6"
64
65 63
9.3"
60 62 60
8.9"
55
8.5"
50
8.1"
45 7.7"
40
35
30
25
20
0 20 40 60 80 100 120 140 160 180 200 220 240 USGPM
hp
10.0"
6
5 9.6"
9.3"
4
8.9"
8.5"
3
8.1"
7.7"
2
0
0 20 40 60 80 100 120 140 160 180 200 220 240 USGPM
ft
10.0"
6 7.7"
0
0 20 40 60 80 100 120 140 160 180 200 220 240 USGPM
32
CANCELS W+SERIES
DATED A-1-201.270 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
10.0" 50 55 η%
300 60
62 63
280 9.6" 64
260 64
9.3" 63
240 62
8.9" 60
220
8.5"
200
8.1"
180 7.7"
160
140
120
100
Pressure head
80
0 50 100 150 200 250 300 350 400 450 500 USGPM
hp
10.0"
45
9.6"
40
35 9.3"
30 8.9"
8.5"
25
8.1"
20 7.7"
15
10
5
Power consumption
0
0 50 100 150 200 250 300 350 400 450 500 USGPM
ft
25 NPSH required 10.0"
7.7"
20
15
10
5 Inducer
0
0 50 100 150 200 250 300 350 400 450 500 USGPM
33
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
50 55 60 65
11.4" 70
100 72
11.0" %
90
10.6"
80 10.2"
9.8"
70
9.4"
60 9.1"
8.7"
50 8.3"
40
30
20
0 50 100 150 200 250 300 350 400 450 USGPM
hp
11.4"
12.5 11.0"
10.6"
10
10.2"
9.8"
7.5
9.4"
9.1"
5 8.7"
8.3"
2.5
0
0 50 100 150 200 250 300 350 400 450 USGPM
ft
8.3" 11.4"
5
2.5
0
0 50 100 150 200 250 300 350 400 450 USGPM
34
CANCELS W+SERIES
DATED A-1-201.275 ISS T
1-1-97
EFFECTIVE 26-04-2010
ft
11.4" 50 55 60
65
70 72 η%
400 11.0"
10.6"
350
10.2"
300 9.8"
9.4"
250 9.1"
8.7"
200 8.3"
150
Pressure head
100
0 100 200 300 400 500 600 700 800 900 USGPM
hp
Power consumption 11.4"
11.0"
100
10.6"
80 10.2"
9.8"
60 9.4"
9.1"
40 8.7"
8.3"
20
0
0 100 200 300 400 500 600 700 800 900 USGPM
ft
NPSH required 8.3" 11.4"
20
10 Inducer
0
0 100 200 300 400 500 600 700 800 900 USGPM
35
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
I
325 II
300
III
275 40 50
60
65
250
68
Impellers:
225
%
200
25 75 125 175 225 275 325 USGPM
hp
40 I
35 II
30
III
25
20
15
10
25 75 125 175 225 275 325 USGPM
ft
III II I
10
0
25 75 125 175 225 275 325 USGPM
36
CANCELS W+SERIES
DATED
1-1-97
NOTE:
ft
I
450
II
400
III
40 50
350 55
60
62
64
66
300 Impellers:
%
250
25 75 125 175 225 275 325 USGPM
hp
55
II
45
III
35
25
15
25 75 125 175 225 275 325 USGPM
ft
III II
10 I
0
25 75 125 175 225 275 325 USGPM
37
Your local contact:
For more information about our worldwide locations, approvals, certifications, and local representatives, please visit www.apv.com.
SPX Corporation reserves the right to incorporate our latest design and material changes without notice or obligation.
Design features, materials of construction and dimensional data, as described in this bulletin, are provided for your information only and should
not be relied upon unless confirmed in writing.