PT PLN (PERSERO) P3B SUMATERA

BIDANG TRANSMISI

GENERATOR DATA

1. TECHNICAL DATA
1.1. GENERATOR

GENERAL DATA
Manufacturer : Type : (Round-Rotor/Salient-Pole)
Nr. of Phase : Frequency : Year :
Rated MVA : Rated Voltage : PF :
Phase Conn. : Rated Current : RPM :
Field Current : Field Voltage :

REACTANCE DATA (PER UNIT) DIRECT AXIS QUADRATURE AXIS


Saturated Synchronous (Xdv) (Xqv)
Unsaturated Synchronous (Xdi) (Xqi)
Saturated Transient (X’dv) (X’q)
Unsaturated Transient (X’di)
Saturated Subtransient (X”dv) (X”qv)
Unsaturated Subtransient (X”di) (X”qi)
Saturated Negative Sequence (X2v)
Unsaturated Negative Sequence (X2i)
Saturated Zero Sequence (X0v)
Unsaturated Zero Sequence (X0i)
Leakage Reactance (XLM, OEX) (XLM,UEX)

Saturation Factor at 100% Terminal Voltage (S100)


Saturation Factor at 120% Terminal Voltage (S120)
If
(Saturation factor at n% are calculated by formula S n  n ; If is field current corresponding to n% terminal
If
voltage on the air gap line/no saturation; Ifn is field current corresponding to n% terminal voltage on open circuit
saturation curve)
Dumping is shaft mechanical dumping term in percent MW change due to 1 Hz deviation in speed (% MW/Hz).
Typical values range from 2% for short shaft to 10% for long shaft.

FIELD TIME CONSTANT (SECOND)


Transient Open Circuit (T’d0) (T’q0)
Three Phase Short Circuit Transient (T’d3) (T’q)
Line to line Short Circuit Transient (T’d2)
Line to Neutral Short Circuit Transient (T’d1)
Short Circuit Subtransient (T”d) (T”q)
Subtransient Open Circuit (T”d0) (T”q0)

1/ 3
PT PLN (PERSERO) P3B SUMATERA
BIDANG TRANSMISI

ARMATURE DC COMPONENT CONSTANT (SECOND)


Three Phase Short Circuit (Ta3)
Line to line Short Circuit (Ta2)
Line to Neutral Short Circuit (Ta1)

PER UNIT ARMATURE WINDING SEQUENCE RESISTANCE


Positive (R1)
Negative (R2)
Zero (R0)
Saturated Armature X/R ratio (X”dv/R1)
Unsaturated Armature X/R ratio (X”di/R1)

Turbine and Generator Combined Inertia Constant (H) kW sec./KVA


Three Phase Armature Winding Capacitance Nanofarads
Armature Winding DC Resistance (per phase) Ohm ( ºC )
Field Winding DC Resistance Ohm ( ºC )
Field Current at Rated KVA, Rated Armature Volt,. Rated PF Amp.
Field Current at Rated KVA, Rated Armature Volt., 0 PF Lagging Amp.*

Inertia constant H is related to the shaft moment inertia, square of generator synchronous speed in RPM, and
generator rated MVA. Total inertia of the generator shaft including the primer-mover and coupling gear in MW-
sec/MVA can be calculated by formula H  2.31  10 10  WR 2  RPM 2 / MVA with WR 2 is moment of inertia
in lb-ft2 or H  5.48  10 9  WR 2  RPM 2 / MVA with WR 2 in kg-m2 or.

1.2. TURBIN
GENERAL DATA
Manufacturer : Year :
Serial No. : Type :
Speed : Rated Head :
Rated output :

1.3. GOVERNOR
GENERAL DATA
Manufacturer : Type :
Serial No. : Frequency :
SETTING
Dead Band : Type :
Nr. of Phase : Frequency :
Rated MVA : Rated Voltage :

2/ 3
PT PLN (PERSERO) P3B SUMATERA
BIDANG TRANSMISI

1.4. GENERATOR TRANSFORMER


GENERAL DATA
Manufacturer : Year :
Type : Serial No. :
Vector group : Rated MVA :
Rated Current : Primary Voltage :
Rated Current : Secondary Voltage :
Rated Current : Tertiary Voltage :
Frequency : Impedance (Z%) :
Cooling System :

TAP CHANGER DATA


Manufacturer : Year :
Type : Serial No. :
Tap Position Data
Tap Primary Side Secondary Side
Position Voltage Current Impedance Voltage Current

Additional Data