You are on page 1of 2

Rev.No.

Date Responsible
Flow Measurement with Prandtl Tube
4 Sept 09 BES

Nhà máy Xi-măng Tafico Tafico - 471-FN4 inlet Anemometer and Prandtl Tube
Measurements (Rev 4, 2009).xls
Bộ phận Công nghệ sản xuất

Plant Tafico Altitude 25 m


Measuring point loc471-FN4 inlet Ambient pressure 1,010 mbar
Date 17/10/2018 2:50 PM
Remarks

Geometry of Gas Duct Gas Properties


Round ( 8 points ) Static pressure in duct (+/- -3.74 mbar
Circular cross section Absolute static gas pressu 1,006 mbar
Diameter 540 mm Temperature in duct 32.7 °C

Conc. Density
[vol-%] [kg/Nm3]
Cross section 0.229 m2 O2 21.0 1.429
CO2 0.0 1.964
H2O 0.0 0.804
Selected Instrument N2 (sum calc.) 79.0 1.257

Prandtl- or S-Tube (mbar) Average gas density [kg/Nm3] 1.293


[kg/m3] 1.147
Calibration factor 1

Position Axis 1 Axis 2 Average


Measurement Diameter move in move out move in move out corrected Dp
[mm] [mbar] [mbar] [mbar] [mbar] [mbar] [mbar]
1 17 2.51 2.51 1.584
2 57 3.19 3.19 1.786
3 105 3.22 3.22 1.794
4 174 3.02 3.02 1.738
5 366 3.15 3.15 1.775
6 435 3.29 3.29 1.814
7 483 3.70 3.70 1.924
8 523 1.53 1.53 1.237

Average of 8 measuring points 1.71

Gas velocity in the duct 22.53 m/s


Measured gas flowrate 18,580 m3/h
16,480 Nm3/h
4

3.5

2.5

1.5

1
Colum
nG
Colum
nF
0.5

0
1 2 3 4 5 6 7 8