SattCon OP45/OP45SB

From Program Version 4.0

SattCon OP45 is a unique combination SattCon OP45 can also be used solely ● Programmed using a standard VDU,
of control system and operator interface as an operator interface, communicating or via a personal computer with the
housed in a single unit. Powerful digital with a control system via COMLI. DOX 10 or DOX 5 software package.
and analogue control functions make it SattCon OP45SB has an integral ● Serial ports for VDU, printer, and
suitable for a wide range of machine and SattBus interface instead of COMLI. communication via COMLI or
process control applications. SattBus.
Input/Output signals are connected ● Back-lit LCD displays four lines of 40
using expansion units from the SattCon OP45 delivers these main characters.
SattCon 05 family. Both the original 05 features: ● Numeric keypad plus 11 function
series and the newer Slimline units are ● PID loops and arithmetic functions keys; “Shift” is used to provide a total
compatible with SattCon OP45. for process control. of 22 user-defined keys.
Software Functions in the text. The display can be divided Programming and Backup
PLC Program so that the lowest line is used to display Programming and backup are
The software which controls both the legends for the five top function keys, performed by a standard VDU or with a
process and text output is known as the for use in different operating personal computer using the DOX 10 or
PLC program. As well as logical conditions. DOX 5 program. Software can be
instructions, SattCon OP45 can handle developed off-line using identifiers and
three levels of subroutines, shift comments. Function blocks and library
registers, and sequencers capable of modules make programming easy.
controlling up to 256 sequences of 100 When the program has been transferred
steps each. to the SattCon OP it can be supervised
Execution of a fast loop, which on-line via DOX 10/DOX 5, which still
executes segments of the PLC program Operator Functions shows identifiers etc. Program backup
as fast as 1 ms, can be started via I/O You have full freedom to create your may be made to floppy disc via PC, or
signals. Fast loop is not available in own dialogues and display screens to Flash PROM using the SBUP05
SattCon OP45SB. needed for operator communication. backup unit.
Up to 36 analogue inputs and outputs The built-in keyboard allows manual SattCon OP45SB must be equipped
can be handled. In addition to the start and stop of plant, initiation of text with a DX232 or DX485
control loops provided, the PLC output, menu selections etc. communication board, if it is to be
program can be used to implement Since SattCon OP45 is also a control programmed via a VDU or DOX 10.
alarm points, ramp functions etc. system, it can be used to implement Programming and backup may be
There are instructions for the four process changes very quickly, and can performed over the SattBus network
arithmetic functions, square root rapidly update the operator display. (via an SBC) using PC and the DOX 5
extraction and data handling. For data program.
storage there are 28000 registers.

Timers and Counters


SattCon OP45 has 64 timers and 64
counters.
Communication
Time Channels SattCon OP45 includes an optoisolated
16 programmable time channels can serial interface for programming or Program Documentation
start and stop activities at communication via COMLI. Using the All programmed functions can be
preprogrammed times and days. DX232 (without optic isolation) or shown on the VDU and/or printed out.
DX485G expansion boards two
Controllers separate COMLI channels are provided,
SattCon OP45 has eight control loops as well as a channel for programming. -------------------------------------------------------------------------------------------------
SattCon 05

with P, Pl, PD or PID functions which In addition a printer port is always User:_____________________________________________________

also can be connected in cascade. It is avail-able. Date 98-11-26

Project:___________________________________________________

also possible to have process controlled The text handling includes facilities _________________________________________________________

Controller No.

gain scheduling via the PLC program. for interface to Hayes modem. ---------------------
00 01 xx xx xx xx xx xx

All controller values can be presented Using COMLI, signal status, register Controller No 00
I/O-addresses On/Off 0040
Controller type (P/P1/PD/PID) P1

in bargraph format on the operator values, etc. can be transferred to and Setpoint
Input
(%, AI, R)
(AI, R)
AI100
AI104

display. from other systems which support Sample time


Gain
Integration time
(s)
(..,R)
(s, R)
0.8s
4.50
200.0s

COMLI. COMLI also allows a personal Deadzone: Input-Setpoint


Direct Control
Minimum Out
(%, R)
(Y/N)
(%, R)
0.0%
N
0.0%

Diagnostics computer to transfer programs and data Maximum Out


Digital Output
Output
(%, R)
(Y/N)
(AO, R)
100.0%
N
AO100

The SattCon OP45 has several to and from SattCon OP45. It is also Cascade Controller

Controller No 01
(N/M) N

functions which help fault finding and possible to make changes to the I/O-addresses On/Off
Controller type
Setpoint
(P/P1/PD/PID)
(%, AI, R)
0040
P1
AI100

commissioning, e.g. automatic fault program via the COMLI network (not Input
Sample time
Gain
(AI, R)
(s)
(..,R)
AI104
0.8s
4.50

monitoring of the analogue inputs and valid for DOX 10). Integration time
Deadzone: Input-Setpoint
(s, R)
(%, R)
200.0s
0.0%
Direct Control (Y/N) N

outputs, and dynamic display of SattCon OP45SB communicates via Minimum Out
Maximum Out
(%, R)
(%, R)
0.0%
100.0%
Digital Output (Y/N) N

sequencer steps. SattBus instead of COMLI. SattBus is a Output


Cascade Controller
(AO, R)
(N/M)
AO100
N

two-wire asynchronous token passing


Text Handling and Dialogue bus. A maximum of 120 nodes may be
512 messages of 32 characters can be connected over a maximum length of
used for reports, alarms and dialogue 2000 m. A SattBus network requires
that one of the units is the supervisor. Program documentation can be
messages. Messages can include the enhanced by the inclusion of comments
date, time and process values. SattCon OP45SB does not have this
function and, as a consequence, an SBC and identifiers using a personal
Large numerical values, and values computer with the DOX 5 program.
with up to five decimal places can be (SattBus Converter) must be included
in a SattBus network. You have also the possibility to make
handled if several consecutive registers the documentation in graphical function
are used. In addition to the ability to transfer
and request signal status, register blocks, with the DOX 10 program.
Numerical information may be scaled
automatically and displayed in the values, time etc., programs can also be
correct physical units with up to 5 transferred and requested via SattBus
decimal places. A check of min./max. (not valid for DOX 10).
values is performed at input. The OP45SB can be equipped with a
Any ASCII character can be printed channel for VDU and printer via
out from a register or from the text line. DX232 or DX485G communications
Control codes, for example for board.
positioning the cursor, can be included
Hardware
SattCon OP45 has a low profile and is
designed for mounting on the front of
instrument cabinets and similar
equipment.

Keyboard F1 F2 F3 F4 F5

In addition to the numeric keys for


entering values, there are 11 function 7 8 9 C F6 F7

keys which, used together with the 4 5 6 +/-


F8 F9

SHIFT keys permit 22 memory cells to 1 2 3 E


N
T
E

be accessed. A legend strip can be SHIFT 0 • R


F10 F11

inserted above each key. The keys give


a distinct “mechanical click” to confirm
operation.

Display
The operator interface has a back-lit
LCD display with four rows of 40
characters. The viewing angle can be
adjusted by a potentiometer. Character
sets for seven countries are included,
along with some graphics characters
and functions for horizontal bargraphs.
All ASCII characters can be displayed.

Inputs/Outputs
Up to four expansion units can be
connected to the SattCon OP45 to range may be used. Expansion units are may be ordered as accessory items. All
handle analogue and digital signals. supplied with short connecting cables, I/O units are presented in the data sheet
Any expansion unit in the SattCon 05 however cables with up to 2 m length of SattCon 05 Slimline.

Dimensions

Panel cutout:
205 x 205 mm ±1 mm
203

216

76
216

203
76
Technical Data
CPU Dallas 80C320 or equivalent DOX 5 Software for personal computer. Off-
Program memory 25 kbytes available for the PLC line programming with IDF and
program. CMOS-RAM with battery comments. Some limitations exist
backup, battery life approx. 3 years in DOX 10 Software with off-line-programming
operation, 5 years in storage (25°C). for personal computer. Graphic
Battery type: CR2032 programming is possible
Cycle time Bit instructions: typically 1.2 µs/ Backup Total with SBUP05, DOX 10 and
instruction. DOX 5
Word instructions: typically 20 µs/ Printer connection
instruction
SattCon OP45 RS232 via 25-pole D-type connector
Working memory Total 3072 memory cells, reduced by
the number of inputs and outputs. SattCon OP45SB Via DX232/DX485G
60 memory cells are battery-backed Power supply 24 V -15% +20%. Max. ripple 5%
Timers 64 pcs., 0.1s - 9 h 6 m 7 s (100–120 Hz). Extra power supply is
normally not required for expansion
Counters 64 pcs., 65535 steps, up/down units, although SDA and SACV
counter requires 24 V DC -15% +20% *
16-bit registers 28000 pcs Power consumption 5.7 W (24 VDC) *
Sequencers 256 pcs., with 100 steps each Environment Industrial premises
Time channels 16 pcs. programmable Approvals (when CE-marked and meets EMC directive
Text messages 512 x 32 characters. Time, date and product or packaging 89/336/EEC according to the follow-
process values can be included. is marked) ing standards: EN 50081-2 and
Texts can also be sent to printer. Text EN 50082-2.
handling includes dial-up function via Low Voltage Directive 73/23/EEC
Hayes modem with supplement 93/68/EEC accord-
Controllers 8 pcs. programmable; P, PI, PD or ing to the following standard:
PID EN61131-2
Inputs/outputs Up to 4 expansion units with UL listed according to UL 508
analogue or digital signals or Protection class IP65
combinations of these * Ambient temperature Operating 0–50°C
Pulse input Max 2 kHz. Only when the first I/O Non-operating -25 to +70°C
unit is SD32D or SDA. Not valid for Humidity 10–95%, non-condensing
SattCon OP45SB or if a DX board is
fitted in the OP unit Weight 1.7 kg
Communication Product name Order code
SattCon OP45 1 RS232 or RS485 (galv. separated) SattCon OP45 SCOP45
serial channel, selectable Master/ SattCon OP45/
Slave. With expansion board 2 DX232 SCOP45/DX232
channels are available RS232/ SattCon OP45/
RS485 (DX232 or DX485G) DX485G SCOP45/DX485G
SattCon OP45SB SattBus communication. SattCon OP45SB SCOP45SB
Does not have supervisor function.
120 nodes, max. 2000 m SattCon OP45SB/
DX232 SCOP45SB/DX232
Display Back-lit LCD display 4x40 characters
SattCon OP45SB/
Keyboard 11 keys x 2 for function selection, DX485G SCOP45SB/DX485G
numeric keys etc.
Programming
SattCon OP45 VDU terminal or PC with DOX 10/
DOX 5;
RS232 via 25-pole D-type connector
SattCon OP45SB VDU terminal via DX232/ DX485G or
via SattBus and a SattBus Connector

* For details refer to the Installation and Maintenance manual

Regional Center Sweden Regional Center Americas Regional Center Germany Internet:
Västerås, Sweden Wickliffe, OH, USA Mannheim, Germany www.abb.com
Phone: +46 (0) 21 34 20 00 Phone: +1 (440) 585 8500 Phone: +49 (0) 1805 266776
Fax: +46 (0) 21 13 78 45 Fax: +1 (440) 585 8756 Fax: +49 (0) 1805 776329
Email: Marketing.Control-Products@de.abb.com
Specifications subject to change without notice. 493-0678-11
Printed in Sweden. © 2000 ABB Automation Products AB. All rights to trademarks reside with their respective owners. 9811 Ver. 2-1