You are on page 1of 1

Y1 Y2

2200
APEX OF TRUSS
1200 1000
300 250 400 200 100 250 400 300

300
100
75
SEE SPOT DETAIL

x2
100x100
PEDESTAL COLUMN
CORRUGATED G.I.

100
SHT. ROOFING GA. 24

75
400 400 3"x3"
EAVES 2"x3" good EAVES good lumber
4"∅ OUTLET PIPE TAP lumber RAFTER
1200

400X400 400X400
TO NEAREST EXISTING 2"X3" good
manhole manhole

1500
PUBLIC SEWER lumber girt 10MM∅ RSB
2"x3" GOOD
4"∅ PVC PIPE LUMBER PURLINS
(toilet) 2"x2" wood clip
CLEAN OUT/ CLEAN OUT/
inspection pipe chlorine opening

2"x3" good
x1 lumber COLUMN

SPOT DETAIL
PROJECT LAYOUT PLAN SCALE: 1:20 MILLIMETERS
SCALE: 1:20 MILLIMETERS
4"THK. CHB WALL W/
10MM∅ VERT. AND HOR.

600
2200 BARS SPCD. AT
600MM O.C.
1200 1000
300 100x100 PEDESTAL

100
100

COLUMN W/ 2-10MM∅
4"∅ PVC PIPE clean clean

100
(toilet) NAT.GRD.LN. RSB (SEE SPOT DETAIL)
out out
NAT.GRD.LN.

400
general notes:
300

300

20% AIR
SPACE
4"∅ OUTLET PIPE
4"∅ OUTLET PIPE TAP
100

TAP TO NEAREST
TO NEAREST EXISTING
EXISTING PUBLIC 1. septic tank should be 15.00
PUBLIC SEWER
SEWER meters away from any source of
100MM THK. CHB
water

1400
600
WALL W/ 10MM∅ RSB
1500

10MM∅ MATTING SPCD AT 600MM 4"THK. CHB WALL


1400

1400

W/ 10MM∅ VERT. 2. minimum distance from the


BARS SPCD. AT O.C. ALONG VERT.
AND HOR. BARS outside wall of a building is 2.00
300MM O.C.B.W. & HOR.
SPCD. AT meters
LEACHING 600MM O.C.
DIGESTIVE CHAMBER

200
CHAMBER COARSE
200

AGGREGATES
200
SLOPE=5 %
% SLOPE=5
SLUDGE
200

100

COARSE FOOTING
AGGREGATES
100
100

1200

CROSS SECTION DETAIL


1300

LONGITUDINAL SECTION DETAIL


SCALE: 1:20 MILLIMETERS

SCALE: 1:20 MILLIMETERS

PREPARED BY: PROJECT NAME : CHECKED BY : APPROVED BY : SHEET NO.

V. M. JHEK BUILDERS
SUPPLY OF MATERIALS & SUPERVISION OF 36 UNITS TOILET A
CONTRACTOR
PROJECT LOCATION: BARANGAY TAGANITO, CLAVER, SURIGAO DEL NORTE 22