MH-ATS

Automatic Transfer Switch

Automatic Switching for Dual


Power Source Network

The MH-ATS is a compact solenoid


actuated dual power source automatic
transfer switch.
Compliance to IEC 60947-6-1 &
GB/T 14048.11 Standard.
Designed to operate with high switching
speed and support large load current
capacity up to 5,000A.
Product Overview Key Features
MH-ATS is available in two series, the “S2” and “S3”. Mechanical interlock
Special selection switch mechanism to ensure only one
The “S2 series” is a two-stage transfer design with power source is connected.
capacity available from 20A to 500A. When a
switching signal is received, the switch will transfer Multi-leaf contact clapper
power immediately. Extinguished electrical arcing during switching and
minimize arc damage to contact head.
The “S3 series” is a three-stage transfer design with
capacity available from 20A to 5,000A. An OFF Silver alloy contact head
position allows for motor loads to spin down before Higher load handling capability, minimizing overheating
reconnection to a power source. Alternatively, the and provide long service lifespan.
switch may also be configured to transfer power
source immediately after a switching signal is Solenoid driven switching
Received. Rapid transfer between the active power and standby
power. Option to customize transfer delay with an
The MH-ATS may be interfaced with an optional ATS external ATS controller.
Controller “MH-SCT” to configure for delay time
between switching, voltage limit setting, phase lost Compact size
protection, generator start-up and remote Provide ease of handling, installation in tight space
management control. and simplify maintenance effort.

MH-ATS Product Range (S2 series)


MH-ATS Rated Current (A) Short-time Short Circuit
Switching Mode Number of Poles
Models Ith at 40°C & 400VAC Withstand Current Current with fuse

xb1, xb2 = Internal Control Switch


xa1, xa2 = Internal Control Switch
C = Making coil
S1 = Rectifier
AUX = Auxiliary switch
A1- A2 = Power A side making terminal
B1- B2 = Power B side making terminal

Wiring Circuit Diagram of MH-ATS (S2 Series)


MH-ATS Product Range (S3 series)

MH-ATS Rated Current (A) Short-time Short Circuit Number of


Switching Mode Withstand Current Current with fuse
Models Ith at 40°C & 400VAC Poles

C = Making coil AX, BX = Control switch


SC = Selection coil TC = Trip coil AUX = Auxiliary switch
S1 = Rectifier A1- A2 = Power A side making terminal
LS = Selection switch B1- B2 = Power B side making terminal
ATS1, ATS2 = Power A breaking terminal AT1- AT2 = Power A side trip terminal
BTS1, BTS2 = Power B breaking terminal BT1- BT2 = Power B side trip terminal

Wiring Circuit Diagram of MH-ATS (S3 Series)


MH-SCT Controller

The MH-SCT are microprocessor based


controller for the MH-ATS product range. MH­SCT ATS Controller

User configurable settings can be


programmed to customize the MH-ATS ATS CONTROLLER
operation for specific requirements. Control voltage:240V

The MH-SCT-2 is a compact design model


for local control of ATS up to 500A capacity.

The MH-SCT-3 carries advance protection


features and allows remote operation
control via an optional RS-485 interface.
Model: MH-SCT-2 Model: MH-SCT-3
This enables the MH-ATS to be managed
remotely by an external software.

Specification MH-SCT-2 MH-SCT-3


Panel mounted, LED single line display Panel mounted, LED multi segment display
Type
(permanently lit) (auto screen saver)
Operating Condition 230~240VAC, 50Hz 230~240VAC, 50Hz
Panel Cut Out: 130mm (W) x 118mm (H) Panel Cut Out: 187mm (W) x 168mm (H)
Installation Dimension
Bezel Dimension: 142mm (W) x 130mm (H) Bezel Dimension: 196mm (W) x 175mm (H)
Interface to ATS 4x Relay Output for ATS switch control 4x Relay Output for ATS switch control
1x Dry contact input point to transfer switch 1x Dry contact input point to transfer
Remote Interface to OFF state (applicable with MH-S3 ATS switch to OFF state (applicable with MH-S3
models only) ATS models only)
RS-485 communication interface for
Optional Item Not Applicable
remote control upon request
MH-ATS-S3 series MH-ATS-S3 series
ATS Compatibility
MH-ATS-S2 series MH-ATS-S2 series
ATS Capacity Up to 500A Up to 5,000A

Standard Compliance IEC 60947-6-1:1998 IEC 60947-6-1:1998


GB 14048.11-2002 GB 14048.11-2002
Time Delay Adjustment Op
Open Phase Protection
Functions

Automatic Generator Startup


Direct Over-ride Switching
Over Voltage Protection
Under Voltage Protection
Line Voltage Display
RS485 Interface (Optional)
MH-SCT Technical Specification

Parameter Specification

● IEC 60947-6-1 ‘Low voltage switchgear and control gear – Part 6-1 : Multiple
International Standard function equipment – Transfer Switch equipment
Compliance ● GB/T 14048.11

Transfer Time ● Less than or equal to 200ms

● 400VAC (Standard range)


● 660VAC/ 690VAC (Option on request)
Rated Operating Voltage
● 125VDC/ 250VDC (Option on request)

Isolation and Impulse ● Isolation AC 800V


Withstand ● Impulse surge withstand 8kV

● Ambient air temperature: Maximum 40°C and Minimum -5°C


Operating Ambient ● Average maximum relative humidity: Maximum 90%, non-condensing
Conditions ● The operating altitude of the installation site: Maximum 2000m

Pollution Level ● Pollution level conforms to GB/T 14048.1, Level-3

● ATS Switch Module complies with GB/T 14048.1, Category-III


Installation Category ● ATS Controller Module complies with GB/T 14048.1, Category-II

● Both ATS Switch Module and Controller can be installed vertically or horizontally in
Installation Orientation a electrical switch board cabinet

● Rated Source operating voltage of control (Us) for the control device and the
transfer controller is AC 220V / 230V : 50Hz.
Control Circuit ● Operating Source control voltage is between 85% Us and 110% Us.
Factory preset voltage trigger point is Under-voltage 180V, Over-voltage 250V.
User may request other setting when placing order.

● AC-33B: Infrequent Operation. Motor load or composite load inclusive of resistance


load and incandescent lamp load of lower than 30%.
Application Category
● AC-15: Load of controlling alternating electromagnet.
● DC-13: Load of controlling electromagnet.

● The auxiliary contact circuit has a separate electrical structure of 4 normally open
and 4 normally closed contacts.
AUX Circuit ● Rated isolation voltage (Ui) = 300V
● Rated operating current (Ie) = 3A for 220VAC
● Rated operating current (Ie) = 0.2A for 200VDC

● AC-33B (10Ie connected, 10Ie disconnected) cosj =0.35 (When Ie ≤100A, cosj


Disconnection Capacity  =0.45)
● DC-33B (4Ie connected, 4Ie disconnected) L/R=2.5ms
MH-ATS
Dimensions (mm)

Leg en d
A : Width
B : Mounting hole
C : Height
2H : Bar to Bar
J : Depth

Side View Front View

2P 3P 4P
MH-ATS Model
A B C A B C A B C H J
S2/S3 20-63A 185 88 193 227 110 193 229 132 193 112

S2/S3 80-125A 218 103 200 251 133 200 281 163 200 112

S2/S3 160-250A 266 148 197 301 183 197 112

S2/S3 350-500A 355 230 292 415 290 292 132

S3 630-800A 405 375 390 470 440 390 210 160

S3 1000-1200A 450 420 390 530 500 390 250 160

S3 1600A 512 480 390 610 580 390 255 160

S3 2000A 680 595 480 805 748 480 305 170

S3 2500A 680 595 480 805 748 480 335 170

S3 3200A(3P) 915 860 480 335 170

S3 3200A(4P) 1017 956 560 335 215

S3 4000A 915 860 560 1040 940 560 350 215

S3 5000A 1080 1000 560 1160 1040 560 350 215

Note: Picture for illustration only. For detail please refer to Data Sheet.