APT-8S / APT-9S SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this timer.

WEEKLY PROGRAMMABLE TIMER WARNING Warnings are indicated when mishandling this controller might result in death or serious injury
to user.
User's Manual Cautions are indicated when mishandling this controller might result in minor injury to the user,
CAUTION or only physical damage to the timer.

WARNING
RESTRICTIONS ON USE
‧Note this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has
When using this product in applications been correctly wired before turning the power ON.
that require particular safety or when ‧Before wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause
using this product in important facilities, electric shock.
please pay attention to the safety of the ‧Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
‧Do not disassemble the controller. Doing so might cause electric shock or faulty operation.
overall system and equipment. Install fail-
safe mechanisms, perform redundancy CAUTION
checks and periodic inspections and
‧Use the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,
adopt other appropriate safety measures
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
when it is necessary. This product is rated ‧Firmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.
at Class Ⅱ . ‧Press reset before use after turning the battery on or replace the battery.

SPECIFICATIONS BUTTON and SWITCH FUNCTIONS


Operating voltage AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V
Allowable operating
‧ DAY : Day of Week Setup ‧ +1H : Daylight-Saving-Time
voltage range 85 ~ 110% of rated operating voltage
‧ HR : Hour Setup ‧ MAN : Manual Override
Rated frequency 50 / 60 Hz
‧ MIN : Minute Setup ‧ RESET : Program Reset
Contact rating 240VAC 7A(N.O.), 240VAC 5A(N.C.) Resistive load
‧ SEC : Second Setup ‧TIMER
TIMER : Timer Control
Status Indicator POWER - Red / RELAY ON - Green
‧ MODE : Mode Selection ‧PULSE
PULSE : Pulse Output
Power consumption Approx. 3.3VA
‧PROG. : Program Selection ‧min
min : Twin Timer Unit - Hr : Min
Life Mechanical : 5,000,000 times / Electrical : 100,000 times
Ambient temperature -10 ~ +50 C
o ‧START : Start Mode ‧sec
sec : Twin Timer Unit - Min : Sec
Ambient humidity MAX 85% RH
‧CLEAR : Clear Setting ‧ON
ON : Power / Battery On
Weight Approx. 170g ‧ 12/24H : 12H or 24H ‧OFF
OFF : Power / Battery Off
OPERATING FLOWCHART
OFF ON RESET

1 BAT. OR
CLOCK MODE
(Day and Time are flashing under this mode.)
DAY HR MIN CLEAR
5S

MO SU MO TU WE TH FR SA TU TU TU TU TU

SET

Start Clearing EEPROM Clearing EEPROM EEPROM Cleared


Clock Setting Set Day of Week Set Hour Set Minute (APT-9S only) (APT-9S only) (APT-9S only)
MODE

2 Switch to START MODE


START MODE
12/24H +1H MAN MAN
3S

MO MO MO + 1h MO MO
CLK CLK CLK ON OFF CLK ON OFF CLK
AM
PM

Manual ON or OFF Manual ON or OFF


Start Set 12H OR 24H Set Daylight-Saving-Time (Override Current Program) (Override all Programs)

MODE

3 Switch to PROGRAM MODE


PROGRAM MODE
TIMER
DAY
For APT-8S
Timer Output PULSE
DAY MAN HR MIN PROG.
For APT-9S

MO SU MO TU WE TH FR SA TU TU TU
ON ON ON ON OFF
SET SET SET SET SET

Timer Setting Set Day of Week Set Hour Set Minute Set OFF Time
HR MIN CLEAR START

TU TU TU MO
OFF OFF OFF CLK
SET SET SET

Set Hour Set Minute Program Enable Or Disable Start Mode


Example :
A machine is turned on at 8:00 AM and turned off at 5:00 PM, from Monday to Friday. In addition, the machine is turned on between
9:00 AM and 11:00 AM on Saturday for inspection. The correct setting is as followed:
MO TU WE TH FR MO TU WE TH FR SA SA
ON OFF ON OFF
AM SET SET AM SET AM SET
PM

TIMER
DAY
For APT-8S
Pulse Output PULSE
SEC PROG. DAY MAN HR
For APT-9S

MO SU MO TU WE TH FR SA MO TU
ON ON ON
SET SET SET SET SET

Pulse Setting Set Pulse Width (Second) Set Program Number Set Day of Week Set Hour
MIN CLEAR START

MO TU MO TU MO
ON ON CLK
SET SET

Set Minute Program Enable Or Disable Start Mode


Example :
A factory has a buzzer to remind workers of their work time and break time . The buzzer is activated at 8:00, 12:00, 13:00, and 17:00,
from Monday to Saturday. The buzzer duration is 10-second. The correct setting is as followed:

MO TU WE TH FR SA MO TU WE TH FR SA MO TU WE TH FR SA MO TU WE TH FR SA
ON ON ON ON
SET SET SET SET SET

MODE

4 Switch to HOLIDAY SUSPENSION MODE


HOLIDAY SUSPENSION MODE
(This step is optional.) Example :
DAY MAN START
9-day holiday suspension
MO SU MO TU WE TH FR SA TU MO starting from Saturday 0:00 9 days
CLK
SET SET SET SA FR SA SU SA SU MO
SET
Holiday setting Set holiday start day Set holiday duration (day) Start holiday suspension
MODE

5 Switch to TWIN TIMER MODE


TWIN TIMER MODE
(This step is optional. Please note, when Twin Timer Mode is enabled, the program will be disabled.)
min min PROG. HR MIN SEC
/ /
sec sec

OFF Twin Timer Unit - Hr : Min Twin Timer Unit - Min : Sec ON OFF ON
Max. is 99 Hr 59 Min OR Max. is 99 Min 59 Sec SET SET
TMR TMR TMR

Twin Timer setting Set ON time duration Set Hr : Min or Min : Sec
PROG HR MIN SEC START
/ /
OFF ON ON OFF
SET
TMR TMR TMR

Set OFF time duration Set Hr : Min or Min : Sec Start or stop timming
MODE

Switch to CLOCK MODE

CONNECTION POWER BACKUP FEATURE


When APT and the load have When APT and the load share
separate power source the same power source The timer can retain clock operation and program
N Type N Type memory when the external power fails. Under any
Program
power failure, the contact position will be held at Power
P RO GRA MM A B L E TIME R P R OGR A MMA B LE TI ME R
OFF position. When the power is restored, the Output failure
output relay will restore contact status according
to the program.(See chart at right)
12/24H +1H MAN 12/24H +1H MAN
DAY HR MIN SEC DAY HR MIN SEC

MODE PROG. START CLEAR MODE PROG. START CLEAR


PROGRAM OVERLAPPING TIMEING CHART
min min
TIMER OFF ON RESET TIMER OFF ON RESET
ON OFF ON OFF
GREEN RED GREEN RED
PULSE BAT. PULSE BAT.
sec APT-9S sec APT-9S
Timer: Pulse: Holiday:
3 days
Program1 Program1
Th Fr Sa Su Mo
Program2 Program2 Program
LOAD LOAD
Output Output Output
LOAD N L N L
SOURCE SOURCE SOURCE

BATTERY CHANGE CONVERT Y TYPE (Flush Mounting) TO N TYPE (Surface Mounting)

① ② ① ② ③
Lithium battery

CR2032
+
3 VOLTS

CONVERT N TYPE (Surface Mounting) TO Y TYPE (Flush Mounting)

① ② ③ ④

ANLY ELECTRONICS CO., LTD. M-APT9-M-A


http://www.anly.com.tw Printed in Taiwan