30 | VRF systems

SYSVRF
VRF systems | 31

SYSVRF multi-zone solutions:


light commercial and commercial VRF systems
The SYSVRF modular systems are most valuable for room All SYSVRF systems are equipped with DC Inverter
space from 100 to 1000 sq.m. with large independence compressors and DC Inverter fans which gives enhanced
of climatic zones - hotels, restaurants, retail, office system performance and very low operating noise.
buildings, etc. Up to 4 modular outdoor units can be The new generation of 3-pipe systems are equipped with
combined in one single refrigerant system thus reaching all DC Inverter compressor which delivers outstanding
up to 200kW of cooling capacity and connecting up to 64 comfort pleasure and reduces tremendously the
indoor units. In the same system they are able to fulfill electricity consumption.
the increasing demands of air comfort still having low
operating costs.

SYSVRF of Systemair are available with different


configurations: the typical heat pump Mini and Modular
2-pipe outdoor units or the superior Modular heat
recovery 3-pipe units.

SYSVRF Mini and SYSVRF Modular systems

SYSVRF AIR EVO HP Mini 34 SYSVRF DUCT 54

SYSVRF AIR EVO HP 36 SYSVRF DUCT HP 56

SYSVRF AIR EVO HR 40 SYSVRF HRV 58

SYSVRF WALL 46 SYSCONTROL AHU 60

SYSVRF CASSETTE MINI 48 SYSVRF selection software 61

SYSVRF CASSETTE 50 SYSCONTROL systems 62

SYSVRF CEILING 52 SYSVRF JOINT accessories 64


32 | VRF systems

VRF Systemair- SYSVRF


Multi-zone air conditioning system A balanced lineup
95)V\VWHPVDUHPRVWEHQHʾFLDOIRUVSDFHXSWR The lineup of multizone VRF series are continuously
2000 sq.m. with large independence of climatic zones – optimized. In response to market demands Systemair
KRWHOVUHVWDXUDQWVUHWDLOVSDFHRIʾFHEXLOGLQJVHWF offers several types and sizes of indoor units: wall-
,QWKHVDPHV\VWHPWKH\DUHDEOHWRIXOʾOOWKHLQFUHDVLQJ PRXQWHGFDVVHWWHʿRRUFHLOLQJDQGGXFW
demands of the parameters of air in each room and still Outdoor units Mini, despite the compact dimensions ,
have low operating costs. solve different tasks of air conditioning on small objects.
Six modular outdoor units can be combined in one
refrigerant system thus reaching a total cooling capacity
of up to 200 kW.
Separately, to highlight the 3 Pipe heat recovery system
for indipendent and simultaneous cooling and heating
operation.

&RQWLQXRXVGHYHORSPHQWLQWKHʾHOGRIPDQDJHPHQW
In modern air-conditioning systems the demand for
automation and control systems integrated with other
infrastructure building systems is continuously increasing.
These are exactly the principles on the basic of the
development of the control systems of Systemair.
In addition to the traditional control systems of air
conditioning, the user deals with different possibilities of
The most comfortable temperature control that can solve the various needs of the building
An important advantage of the multi-zone air-conditioning management such as the possibility of control via
is a smooth and rapid achievement of a comfortable personal computer and Internet network connection.
WHPSHUDWXUHDVZHOODVPDLQWDLQLQJWKHVSHFLʾHG
parameters accurate to ± 0,5 °C. Such high performance Simplicity of design
was achieved thanks to an accurate control of the Systemair provides full integration and coordination of
UHIULJHUDQWʿRZDQGWKHPHFKDQLVPRIUHGLVWULEXWLRQRI DOOHOHPHQWVRIDPXOWL]RQHV\VWHPJUHDWO\VLPSOLʾHV
refrigerant between the several units, implemented with the task of the designer. The selection process can be
the help of electronic expansion valves. performed in maximum short period of time by using a
simple and complete selection and designing software.
+LJKHQHUJ\HIʾFLHQF\
7KHHIʾFLHQF\RIPXOWL]RQHV\VWHPVLVYHU\KLJKEHFDXVH
each time the electric power is consumed as much as
necessary to carry out user requirements.
If the indoor units work only in a few areas of the building,
then the power consumption is reduced proportionally by
FKDQJLQJWKHUHIULJHUDQWʿRZ

Low noise
Low noise of both outdoor and indoor units makes the job
a multizone system virtually inconspicuous.
VRF systems | 33

SYSVRF lineup
In 2014 Systemair has launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of
work lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the
high standards set by the industry.
7KURXJKWKHXVHRIPRGHUQWHFKQRORJLHVDQGLPSOHPHQWDWLRQRIWKHLURZQGHYHORSPHQWKDVVLJQLʾFDQWO\LPSURYHGHQHUJ\
HIʾFLHQF\ DQG GHFUHDVHG WKH QRLVH OHYHO ZLWK FRPSDFW GLPHQVLRQV LQFUHDVHG HDVH RI LQVWDOODWLRQ DQG PDLQWHQDQFH
greatly expanded the range of application from light commercial to large commercial spaces.

SYSVRF outdoor units

SYSVRF mini SYSVRF modular SYSVRF modular


2 Pipe Heat Pump 3 Pipe Heat Recovery 2 Pipe Heat Pump
12,0-16,0 kW 25,0-180,0 kW 25,0 - 200,0 kW

SYSVRF WALL SYSVRF CEILING

1,5-5,6 kW 3,6-14,0 kW
SYSVRF Indoor units

SYSVRF CASSETTE MINI SYSVRF CASSETTE

2,2-5,6 kW 2,8-14,0 kW

SYSVRF DUCT SYSVRF DUCT HP

2,2-14,0 kW 7,1-28,0 kW

SYSVRF HRV SYSCONTROL AHU


7,0-73 kW
500-2.000 m /h
3

Compatible outdoor and indoor series


Outdoor units of the SYSVRF Mini, Heat Pump and Heat Recovery series are compatible with all types of SYSVRF indoor
units. There are 6 different types of indoor units available with capacity from 1,5 kW to 28,0 kW, making the total number
of indoor units equal to 40 different types and capacities.
The ventilation function can be provided through the SYSVRF HRV units or through the combination of a Systemair air
handling unit with the control module SYSCONTROL AHU.
34 | Mini VRF

Mini VRF Heat Pump Outdoor Units


SYSVRF AIR EVO HP
Features

Full DC Inverter Mini VRF with DC Inverter compressor


and DC fan motor.
Compact size and long piping system.
High efficiency at partial load.
Inverter Rotary compressor providing wide capacity
output from 10% to 100% evenly.
Centralized control, BMS connection and web access
potential.
Hydrophilic Blue Fin coil enhances durability
and protection against corrosion.
Piping connection in four different directions makes
simple the installation of outdoor unit.
Maximum 7 indoor units connection.
Indoor unit combination total capacity index from 45%
to 130%.

Dimensions
H

A
Model 120 140 160
A 900 900 900
B B 600 600 600
C 348 348 348
D 320 320 320
E 400 400 400
E
D

F
C

F 360 360 360


H 1.327 1.327 1.327
Mini VRF | 35

Technical features

Model Indoor unit SYSVRF 120 AIR EVO HP Q 140 AIR EVO HP R 160 AIR EVO HP R
Art. no. 314089 314092 314094
Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50
Cooling capacity kW 12,3 14,0 15,5
Power Input kW 3,25 3,95 4,52
EER 3,78 3,54 3,43
Heating capacity kW 13,2 15,4 17,0
Power Input kW 3,47 4,16 4,77
COP 3,80 3,70 3,56
Max. current A 36 12
Quantity pcs 1
Compressor
Power Input W 3.010 3.010 4.240
Inverter Rotary
Refrigerant oil ml 870+630 870+630 1.400+250
$LUʿRZ m3/h 6.000
Sound pressure level dB(A) 57
Type R410A
Refrigerant
Refrigerant charge kg 3,3 3,9 3,9
Dimension LxWxH mm 900x320x1.327
Packing LxWxH mm 1.030x435x1.456
Net/gross weight kg 95/106 95/106 102/113
Liquid pipe mm (in) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 15,9 (5/8”)
Max qty. indoor units connection pcs 6 6 7
Operating ambient temp. range °C Cooling -15 ... +48 / Heating -15 ... +27

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m
Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.


100 m
0D[LPXPSLSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.


30 m 8m

Maximum indoor unit to indoor unit drop height. 20 m

Outdoor units SYSVRF AIR EVO HP Permitted value


Total piping lenght (actual) 100 m
Actual lenght 60 m
Maximum piping
Piping lenght Aquivavent lenght 70 m
3LSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLWEUDQFK 
20 m
equivalent lenght

Outdoor unit-indoor Outdoor unit up 30 m


Drop height unit drop height Outdoor unit down 20 m
Indoor unit to indoor unit drop height 8m
36 | VRF Heat Pump

Modular VRF Heat Pump Outdoor Units


SYSVRF AIR EVO HP
SYSVRF 252-280 SYSVRF 335-400-450
AIR EVO HP R AIR EVO HP R
Features

Wide application area due to incredible piping lenght


and wide operating temperature range.
Free modular combination of 6 basic units, up to a total
capacity of maximum 200 kW.
Top class energy efficiency.
DC Inverter Scroll compressor provinding wide capacity
output from 10% to 100% evenly.
DC Inverter fan motor.
SYSVRF 500 AIR EVO HP R
High performance of the new designed heat
exchanger.
External static pressure up to 60 Pa (factory option, 20
Pa standard).
Maximum 64 indoor unit connection.
Indoor unit combination total capacity index from 50%
to 130%.
Centralized control, BMS connection and web access
potential.

Dimensions
SYSVRF 252/280 AIR EVO HP R SYSVRF 335/400/450/500 AIR EVO HP R

1250
1615

1615

960
765

765
VRF Heat Pump | 37

Technical features

252 AIR 280 AIR 335 AIR 400 AIR 450 AIR 500 AIR
Model Indoor unit SYSVRF
EVO HP R EVO HP R EVO HP R EVO HP R EVO HP R EVO HP R
Art. no. 314078 314079 314080 314081 314082 314083
Power Supply V/Ph/Hz 380-415/3/50
Cooling capacity kW 25,2 28,0 33,5 40,0 45,0 50,0
Power Input kW 5,88 7,20 9,05 12,31 14,02 15,20
EER 4,29 3,89 3,7 3,25 3,21 3,29
Heating capacity kW 27,0 31,5 37,5 45,0 50,0 56,0
Power Input kW 6,15 7,61 8,99 11,19 12,79 14,25
COP 4,39 4,14 4,17 4,02 3,91 3,93
Max. current A 20,8 22,1 23,7 31,8 32,8 35,4
Quantity pcs 1
Compressor
Capacity W 31.590 31.590 11.800 31.590 31.590 31.590
Inverter Scroll
Refrigerant oil ml 500 500 500 500 500 500
Quantity pcs - - 1 1 1 1
Compressor
Capacity W - - 17.100 13.390 13.390 20.900
Fixed Scroll
Refrigerant oil ml - - 500 500 500 500
$LUʿRZ m3/h 11.500 15.100 15.600 15.600 15.600
Sound pressure level dB(A) 57 59 60 61
Type R410A
Refrigerant
Refrigerant charge kg 9 11 13 16
Dimension (LxWxH) mm 960x765x1.615 1.250x765x1.615
Packing (LxWxH) mm 1.025x830x1.790 1.305x825x1.790
Net/gross weight kg 198/213 266/288 280/300 300/320
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 19,1 (3/4”)
Piping dimension Gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Oil balance pipe mm (in) 6,35 (1/4”)
Operating ambient temp. range °C Cooling -5 ... +48 / Heating -20 ... +24

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 5m 0m
Heating mode 20°C DB, 19°C WB 7°C DB, 6°C WB 5m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.

0D[LPXPSLSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.

Maximum indoor unit to indoor unit drop height.

Outdoor units SYSVRF 252 to 2000 AIR EVO HP R Permitted value


Total piping lenght (actual) 1.000 m
Actual lenght 175 m
Maximum piping
Piping lenght Aquivavent lenght 200 m
3LSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLWEUDQFK 
40 m/90 m*
equivalent lenght

Outdoor unit-indoor Outdoor unit down 110 m


Drop height unit drop height Outdoor unit up 50 m/70 m**
Indoor unit to indoor unit drop height 30 m

:KHQWKHIDUWKHVWSLSHOHQJWKLVPRUHWKDQPLWQHHGVWRPHHWVSHFLʾFFRQGLWLRQVDFFRUGLQJWRWKHLQVWDOODWLRQSDUWRIWKHWHFKQLFDOPDQXDO
** Level difference: less or equal to 50m is standard; more than 50m is available to be customized.
38 | VRF Heat Pump combination

Outdoor unit combination SYSVRF AIR EVO HP


Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

25,2/27 SYSVRF 252 AIR EVO HP R SYSVRF 252 AIR EVO HP R - 13

28/31,5 SYSVRF 280 AIR EVO HP R SYSVRF 280 AIR EVO HP R - 16

33,5/37,5 SYSVRF 335 AIR EVO HP R SYSVRF 335 AIR EVO HP R - 20

40/45 SYSVRF 400 AIR EVO HP R SYSVRF 400 AIR EVO HP R - 23

45/50 SYSVRF 450 AIR EVO HP R SYSVRF 450 AIR EVO HP R - 26

50/56 SYSVRF 500 AIR EVO HP R SYSVRF 500 AIR EVO HP R - 29

SYSVRF JOINT
56/63 SYSVRF 560 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 33
OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


61,5/69 SYSVRF 615 AIR EVO HP R 36
+ SYSVRF 335 AIR EVO HP R OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


68/76,5 SYSVRF 680 AIR EVO HP R 39
+ SYSVRF 400 AIR EVO HP R OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


73/81,5 SYSVRF 730 AIR EVO HP R 43
+ SYSVRF 450 AIR EVO HP R OUT 02 HP

SYSVRF 280 AIR EVO HP R SYSVRF JOINT


78/87,5 SYSVRF 780 AIR EVO HP R 46
+ SYSVRF 500 AIR EVO HP R OUT 02 HP

SYSVRF 400 AIR EVO HP R SYSVRF JOINT


85/95 SYSVRF 850 AIR EVO HP R 50
+ SYSVRF 450 AIR EVO HP R OUT 02 HP

SYSVRF 400 AIR EVO HP R SYSVRF JOINT


90/101 SYSVRF 900 AIR EVO HP R 53
+ SYSVRF 500 AIR EVO HP R OUT 02 HP

SYSVRF 450 AIR EVO HP R SYSVRF JOINT


95/106 SYSVRF 950 AIR EVO HP R 56
+ SYSVRF 500 AIR EVO HP R OUT 02 HP

SYSVRF JOINT
100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 59
OUT 02 HP
VRF Heat Pump combination | 39

Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

SYSVRF 280 AIR EVO HP R x2 SYSVRF JOINT


106/119 SYSVRF 1060 AIR EVO HP R 63
+ SYSVRF 500 AIR EVO HP R OUT 03 HP

SYSVRF 280 AIR EVO HP R


SYSVRF JOINT
113/126,5 SYSVRF 1130 AIR EVO HP R + SYSVRF 400 AIR EVO HP R 64
OUT 03 HP
+ SYSVRF 450 AIR EVO HP R

SYSVRF JOINT
120/135 SYSVRF 1200 AIR EVO HP R SYSVRF 400 AIR EVO HP R x3 64
OUT 03 HP

SYSVRF 280 AIR EVO HP R


SYSVRF JOINT
123/137,5 SYSVRF 1230 AIR EVO HP R + SYSVRF 450 AIR EVO HP R 64
OUT 03 HP
+ SYSVRF 500 AIR EVO HP R

SYSVRF 280 AIR EVO HP R + SYSVRF JOINT


128/143,5 SYSVRF 1280 AIR EVO HP R 64
SYSVRF 500 AIR EVO HP R x2 OUT 03 HP

SYSVRF 400 AIR EVO HP R


SYSVRF JOINT
135/151 SYSVRF 1350 AIR EVO HP R + SYSVRF 450 AIR EVO HP R 64
OUT 03 HP
+ SYSVRF 500 AIR EVO HP R

SYSVRF 400 AIR EVO HP R + SYSVRF JOINT


140/157 SYSVRF 1400 AIR EVO HP R 64
SYSVRF 500 AIR EVO HP R x2 OUT 03 HP

SYSVRF 450 AIR EVO HP R + SYSVRF JOINT


145/162 SYSVRF 1450 AIR EVO HP R 64
SYSVRF 500 AIR EVO HP R x2 OUT 03 HP

SYSVRF JOINT
150/168 SYSVRF 1500 AIR EVO HP R SYSVRF 500 AIR EVO HP R x3 64
OUT 03 HP

SYSVRF 280 AIR EVO HP R x2 SYSVRF JOINT


156/175 SYSVRF 1560 AIR EVO HP R 64
+ SYSVRF 500 AIR EVO HP R x2 OUT 04 HP

SYSVRF 280 AIR EVO HP R


+ SYSVRF 400 AIR EVO HP R SYSVRF JOINT
163/182,5 SYSVRF 1630 AIR EVO HP R 64
+ SYSVRF 450 AIR EVO HP R OUT 04 HP
+ SYSVRF 500 AIR EVO HP R
SYSVRF 280 AIR EVO HP R
SYSVRF JOINT
168/188,5 SYSVRF 1680 AIR EVO HP R + SYSVRF 400 AIR EVO HP R 64
OUT 04 HP
+ SYSVRF 500 AIR EVO HP R x 2
SYSVRF 280 AIR EVO HP R
SYSVRF JOINT
173/193,5 SYSVRF 1730 AIR EVO HP R + SYSVRF 450 AIR EVO HP R 64
OUT 04 HP
+ SYSVRF 500 AIR EVO HP R x 2

SYSVRF 280 AIR EVO HP R + SYSVRF JOINT


178/199,5 SYSVRF 1780 AIR EVO HP R 64
SYSVRF 500 AIR EVO HP R x 3 OUT 04 HP

SYSVRF 400 AIR EVO HP R +


SYSVRF JOINT
185/207 SYSVRF 1850 AIR EVO HP R SYSVRF 450 AIR EVO HP R + 64
OUT 04 HP
SYSVRF 500 AIR EVO HP R x 2

SYSVRF 400 AIR EVO HP R + SYSVRF JOINT


190/213 SYSVRF 1900 AIR EVO HP R 64
SYSVRF 500 AIR EVO HP R x 3 OUT 04 HP

SYSVRF 450 AIR EVO HP R + SYSVRF JOINT


195/218 SYSVRF 1950 AIR EVO HP R 64
SYSVRF 500 AIR EVO HP R x 3 OUT 04 HP

SYSVRF JOINT
200/224 SYSVRF 2000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x 4 64
OUT 04 HP
40 | VRF Heat Recovery

Modular VRF Heat Recovery Outdoor Units


SYSVRF AIR EVO HR
Features

Simultaneous operation in cooling and heating mode


provides more comfort and reduces power consumption.
Wide application area due to incredible piping lenght
and wide operating temperature range.
Free modular combination of 5 basic units, up to a total
capacity of maximum 180 kW.
Top class energy efficiency.
All DC Inverter Scroll compressors providing wide
capacity output from 10% to 100% evenly.
DC fan motor.
High performance of the new designed heat
exchanger with double refrigerant circuit.
External static pressure up to 40 Pa (20 Pa standard).
Maximum 64 indoor unit connection.
Indoor unit combination total capacity index from 50%
to 130%.
Centralized control, BMS connection and web access
potential.
Continous heating output during defrost operation
thanks to the innovative double heat exchanger.

Dimensions
SYSVRF 252/280/335/400/450 AIR EVO HR R

1250
1615

765
VRF Heat Recovery | 41

Technical features

252 AIR EVO 280 AIR EVO 335 AIR EVO 400 AIR EVO 450 AIR EVO
Model Indoor unit SYSVRF
HR R HR R HR R HR R HR R
Art. no. 314084 314085 314086 314087 314088
Power Supply V/Ph/Hz 380-415/3/50, 380-415/3/60
Cooling capacity kW 25,2 28,0 33,5 40,0 45,0
Power Input kW 5,73 6,67 8,07 11,30 13,24
EER 4,40 4,20 4,15 3,54 3,40
Heating capacity kW 27,0 31,5 37,5 45,0 50,0
Power Input kW 6,00 7,33 8,72 11,19 12,79
COP 4,50 4,30 4,30 4,02 3,91
Max. current A 20,8 22,1 22,8 31,8 32,8
Quantity pcs 1 1 1 2 2
Compressor
Capacity W 31.590 31.590 31.590 31.590+11.800
Inverter Scroll
Refrigerant oil ml 500 500 500 500+500
$LUʿRZ m3/h 12.000 12.000 13.000 15.000 15.000
Sound pressure level dB(A) 57 58 60 60
Type R410A
Refrigerant
Refrigerant charge kg 10 10 10 14
Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615
Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790
Net/gross weight kg 255/273 303/322
Liquid pipe mm (in) 9,5 (3/8”) 12,7 (1/2”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)
Low pressure gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”) 28,6 (1 1/8”) 28,6 (1 1/8”)
Piping dimension High pressure gas pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”)
Oil balance pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Gas balance pipe mm (in) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”)
Operating ambient temp. range °C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 7,5 m 0m
Heating mode 20°C DB, 15°C WB 7°C 7,5 m 0m

The sound pressure value may vary depending on ambient conditions.

Piping Lenght

Maximum piping equivalent lenght.

0D[LPXPSLSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW
branch) equivalent lenght.

Maximum outdoor unit-indoor unit drop height.

Maximum indoor unit to indoor unit drop height.

Outdoor units SYSVRF 252 to 1800 AIR EVO HR R Permitted value


Total piping lenght (actual) 1.000 m
Actual lenght 175 m
Maximum piping
Piping lenght Aquivavent lenght 200 m
3LSLQJ WKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLWEUDQFK 
40 m/90 m*
equivalent lenght

Outdoor unit-indoor Outdoor unit up 110 m


Drop height unit drop height Outdoor unit down 50 m/70 m**
Indoor unit to indoor unit drop height 30 m

:KHQWKHIDUWKHVWSLSHOHQJWKLVPRUHWKDQPLWQHHGVWRPHHWVSHFLʾFFRQGLWLRQVDFFRUGLQJWRWKHLQVWDOODWLRQSDUWRIWKHWHFKQLFDOPDQXDO
** Level difference: less or equal to 50m is standard; more than 50m is available to be customized.
42 | VRF Heat Recovery switch module

Mode Switch module


for VRF Heat Recovery systems
SYSVRF BOX HR
Features SYSVRF BOX 02 HR SYSVRF BOX 06 HR

Simultaneous heating and cooling in a single refrigerant


system thanks to the combination of SYSVRF HR
outdoor units and the SYSVRF BOX modules.
SYSVRF BOX HR is available in 3 different modules with
2, 4 or 6 outlets and combination up to 24 indoor units SYSVRF BOX 04 HR
from a single module.
SYSVRF BOX 02-1 HR and 04-1 HR can connect only
 RQHLQGRRUXQLWDQGWKH\DUHVSHFLʾFDOO\GHVLJQHGIRU
the combination with SYSCONTROL AHU and Systemair
air handling units.
Compact and light design, it can be installed in narrow Independent sub-cooling circuit for each SYSVRF BOX
space. HR module.

Heating Heating Heating Off Cooling Cooling

Dimensions SYSVRF BOX

SYSVRF BOX SYSVRF BOX SYSVRF BOX


02 HR 04 HR 06 HR
A 630 960 960
B 600 600 600
C 225 225 225
D 490 820 820
E 300 300 300
VRF Heat Recovery switch module | 43

Technical features

SYSVRF BOX SYSVRF BOX SYSVRF BOX


Model
02 HR 04 HR 06 HR
Art. no. 314161 314162 314186
Power Supply V/Ph/Hz 220-240/1/50
Max indoor unit groups 2 4 6
Max number of each group indoor units 4 4 4
Max number of all downstream indoor units 4x2=8 4x4=16 4x6=24
Max capacity of each group indoor units kW 16 16 16
Total capacity of all downstream indoor units kW   
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)
Connect to outdoor unit High pressureg gas pipe mm (in) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Piping connections Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”)
Connect to indoor unit
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”)
Dimension (LxWxH) mm 630x225x600 960x225x600 960x225x600
Packing (LxWxH) mm 725x325x685 1.055x325x685 1.055x325x685
Net/gross weight kg 19,5/27 31/40 35/44,5

SYSVRF BOX SYSVRF BOX


Model
02-1 HR 04-1 HR
Art. no. 313550 313551
Power Supply V/Ph/Hz 220-240/1/50
Max number of indoor unit 1 1
Max capacity of indoor unit kW 20-28 40-56
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Connect to outdoor unit High pressure gas pipe mm (in) 19,1 (3/4”) 22,2 (5/8”)
Piping
Low pressure gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”)
connections
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”)
Connect to indoor unit
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”)
Dimension (LxWxH) mm 630x225x600 960x225x600
Packing (LxWxH) mm 725x325x685 1.055x325x685
Net/gross weight kg 19,5/27 31/40

Piping connections SYSVRF BOX

SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR

Liquid pipe 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)


Outdoor unit High pressure pipe 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Low pressure pipe 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Liquid pipe 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”)
Indoor unit
Gas pipe 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”)
44 | VRF Heat Recovery combination

Outdoor unit combination SYSVRF AIR EVO HR


Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

25,2/27 SYSVRF 252 AIR EVO HR R SYSVRF 252 AIR EVO HR R - 13

28/31,5 SYSVRF 280 AIR EVO HR R SYSVRF 280 AIR EVO HR R - 16

33,5/37,5 SYSVRF 335 AIR EVO HR R SYSVRF 335 AIR EVO HR R - 20

40/45 SYSVRF 400 AIR EVO HR R SYSVRF 400 AIR EVO HR R - 23

45/50 SYSVRF 450 AIR EVO HR R SYSVRF 450 AIR EVO HR R - 26

SYSVRF 252 AIR EVO HR R SYSVRF JOINT


53,2/58,5 SYSVRF 532 AIR EVO HR R 29
+ SYSVRF 280 AIR EVO HR R OUT 02 HR

SYSVRF JOINT
56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 33
OUT 02 HR

SYSVRF 280 AIR EVO HR R SYSVRF JOINT


61,5/69 SYSVRF 615 AIR EVO HR R 36
+ SYSVRF 335 AIR EVO HR R OUT 02 HR

SYSVRF 280 AIR EVO HR R SYSVRF JOINT


68/76,5 SYSVRF 680 AIR EVO HR R 39
+ SYSVRF 400 AIR EVO HR R OUT 02 HR

SYSVRF 280 AIR EVO HR R SYSVRF JOINT


73/81,5 SYSVRF 730 AIR EVO HR R 43
+ SYSVRF 450 AIR EVO HR R OUT 02 HR

SYSVRF JOINT
80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 46
OUT 02 HR

SYSVRF 400 AIR EVO HR R SYSVRF JOINT


85/95 SYSVRF 850 AIR EVO HR R 50
+ SYSVRF 450 AIR EVO HR R OUT 02 HR

SYSVRF JOINT
90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 53
OUT 02 HR
VRF Heat Recovery combination | 45

Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty

SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT


96/108 SYSVRF 960 AIR EVO HR R 56
+ SYSVRF 400 AIR EVO HR R OUT 03 HR

SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT


101/113 SYSVRF 1010 AIR EVO HR R 59
+ SYSVRF 450 AIR EVO HR R OUT 03 HR

SYSVRF 280 AIR EVO HR R


SYSVRF JOINT
106,5/119 SYSVRF 1065 AIR EVO HR R + SYSVRF 335 AIR EVO HR R 63
OUT 03 HR
+ SYSVRF 450 AIR EVO HR R
SYSVRF 280 AIR EVO HR R
SYSVRF JOINT
113/126,5 SYSVRF 1130 AIR EVO HR R + SYSVRF 400 AIR EVO HR R 64
OUT 03 HR
+ SYSVRF 450 AIR EVO HR R

SYSVRF JOINT
120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 64
OUT 03 HR

SYSVRF 400 AIR EVO HR R x2 SYSVRF JOINT


125/140 SYSVRF 1250 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R OUT 03 HR

SYSVRF 400 AIR EVO HR R + SYSVRF JOINT


130/145 SYSVRF 1300 AIR EVO HR R 64
SYSVRF 450 AIR EVO HR R x2 OUT 03 HR

SYSVRF JOINT
135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 64
OUT 03 HR

SYSVRF 252 AIR EVO HR R+


SYSVRF JOINT
143,2/158,5 SYSVRF 1432 AIR EVO HR R SYSVRF 280 AIR EVO HR R + 64
OUT 04 HR
SYSVRF 450 AIR EVO HR R x2

SYSVRF 280 AIR EVO HR R x2 SYSVRF JOINT


146/163 SYSVRF 1460 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R x2 OUT 04 HR

SYSVRF 280 AIR EVO HR R +


SYSVRF JOINT
151,5/169 SYSVRF 1515 AIR EVO HR R SYSVRF 335 AIR EVO HR R + 64
OUT 04 HR
SYSVRF 450 AIR EVO HR R x2
SYSVRF 280 AIR EVO HR R +
SYSVRF JOINT
158/176,5 SYSVRF 1580 AIR EVO HR R SYSVRF 400 AIR EVO HR R + 64
OUT 04 HR
SYSVRF 450 AIR EVO HR R x2

SYSVRF 400 AIR EVO HR R x3 SYSVRF JOINT


165/185 SYSVRF 1650 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R OUT 04 HR

SYSVRF 400 AIR EVO HR R x2 SYSVRF JOINT


170/190 SYSVRF 1700 AIR EVO HR R 64
+ SYSVRF 450 AIR EVO HR R x2 OUT 04 HR

SYSVRF 400 AIR EVO HR R + SYSVRF JOINT


175/195 SYSVRF 1750 AIR EVO HR R 64
SYSVRF 450 AIR EVO HR R x3 OUT 04 HR

SYSVRF JOINT
180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 64
OUT 04 HR
46 | VRF Wall indoor units

Wall-Mounted Indoor Units


SYSVRF WALL
Features

 )URQWSDQHORIPRGHUQGHVLJQWKDWʾWVLQWRDQ\
interior decor.
Even and smooth air distribution due to auto swing
function.
Multi-refrigerant outlet pipe method: left/right/rear,
more flexible for installation.
Washable air filter, easy for insertion and removal.
Built-in electronic expansion valve (EXV) ensuring
 SUHFLVHʿRZFRQWURO
Infrared receiver and remote SYSCONTROL RM 02 Infrared remote Wired
control controller
with address setting function as standard equipment.
SYSCONTROL SYSCONTROL
RM 02 WC 90
(standard) (optional)
Accessories/option

Wired controller SYSCONTROL WC 90 with address Wired


controller
setting function for heat pump system.
SYSCONTROL
Wired controller SYSCONTROL WC 120 for heat WC 120
(optional)
recovery system.

Dimensions
B

A
C

Indoor unit SYSVRF WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q


A mm 915 1.072
B mm 290 315
C mm 230 230
VRF Wall indoor units | 47

Technical features

Model Indoor unit SYSVRF WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q
Art. no. 314123 314124 314125 314126 314127 314128
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 1,5 2,2 2,8 3,6 4,5 5,6
Power Input W 28 45
Current A 0,14 0,20 0,33
Heating capacity kW 1,7 2,4 3,2 4,0 5,0 6,3
Power Input W 28 45
Current A 0,14 0,20
$LUʿRZ KLPHGORZ m3/h 525/480/430 590/520/480 860/755/830 925/860/755
Sound pressure level (hi/med/low) dB(A) 35/32/29 40/38/34
Dimension (LxWxH) mm 915x230x290 1.072x230x315
Packing (LxWxH) mm 1.020x315x390 1.180x315x415
Net/gross weight kg 13/16,5 15,1/18,8
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16,5
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


48 | VRF Compact Cassette indoor units

Compact Cassette Indoor Units


SYSVRF CASSETTE MINI
Features

New grille SYSPANEL CASSETTE MINI VRF with 360°


 DLUGLVFKDUJHSURYLGLQJVWURQJFLUFXODWLQJDLUʿRZ
to cool or heat every corner of the room.
Compact casing making it match perfectly with
ambient decoration.
Advanced 3D spiral fan design reducing the air
resistance and operation noise.
Integrated drain pump with a head of 500 mm.
Fresh air hole and reserved ports for duct connection.
Built-in electronic expansion valve (EXV) ensuring
 SUHFLVHʿRZFRQWURO
Infrared receiver and remote SYSCONTROL RM 02 Infrared remote Wired
control controller
with address setting function as standard equipment.
SYSCONTROL SYSCONTROL
RM 02 WC 90
(standard) (optional)
Accessories/option

Wired controller SYSCONTROL WC 90 with address Wired


controller
setting function for heat pump system.
SYSCONTROL
Wired controller SYSCONTROL WC 120 for heat WC 120
recovery system. (optional)

Dimensions

Connecting points of refrigerant pipe (gas/liquid side)


Drain point
60

Hook
647 (panel)

Main body
523
570

260

Nut

50
Ceiling 600 Panel
545
570

647 (panel)
VRF Compact Cassette indoor units | 49

Technical features

CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI
Model Indoor unit SYSVRF
22 Q 28 Q 36 Q 45 Q 56 Q
CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI
Model Panel unit SYSPANEL
VRF VRF VRF VRF VRF
Art. no. Indoor unit 314095 314096 314097 314098 314099
Art. no. Panel unit 313324 313324 313324 313324 313324
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6
Power Input W 48 48 56
Current A 0,175 0,21
Heating capacity kW 2,4 3,2 4,0 5,0 6,0
Power Input W 48 56
Current A 0,175 0,21
$LUʿRZ KLPHGORZ m3/h 522/414/313 610/521/409
Sound pressure level (hi/med/low) dB(A) 35,8/33,4/23,4 41,5/35,6/28,8
Dimension (LxWxH) mm 570x570x260
Unit Packing (LxWxH) mm 675x675x285
Net/gross weight kg 17,5/22 19/23,5
Dimension (LxWxH) mm 647x675x50
Panel Packing (LxWxH) mm 705x705x113
Net/gross weight kg 3/5
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3,8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 25
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


50 | VRF Cassette indoor units

Standard Cassette Indoor Units


SYSVRF CASSETTE
Features

New grille SYSPANEL CASSETTE EVO with 360° air


 GLVFKDUJHSURYLGLQJVWURQJFLUFXODWLQJDLUʿRZWRFRRO
or heat every corner of the room.
Ultra-thin casing for easy installation into a shallow
ceiling.
Advanced 3D spiral fan design reducing the air
resistance and operation noise.
Integrated drain pump with a head of 750 mm.
Fresh air hole and reserved ports for duct connection.
Built-in electronic expansion valve (EXV) ensuring
 SUHFLVHʿRZFRQWURO
Infrared receiver and remote SYSCONTROL RM 02 Infrared remote Wired
control controller
with address setting function as standard equipment.
SYSCONTROL SYSCONTROL
RM 02 WC 90
(standard) (optional)
Accessories/option

Wired controller SYSCONTROL WC 90 with address Wired


controller
setting function for heat pump system.
SYSCONTROL
Wired controller SYSCONTROL WC 120 for heat WC 120
recovery system. (optional)

Dimensions

950
780 105 Φ32 Drain pipe
A outter diameter 70

≥20
55
950
680

840

146

Ceiling 46
Panel
Main body
B 840
Φ75 New air
supply orifice 904

CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE


Indoor unit SYSVRF
28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
A mm 230 230 300
B mm 170 170 190
VRF Cassette indoor units | 51

Technical features

CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE


Model Indoor unit SYSVRF
28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE CASSETTE
Model Panel unit SYSPANEL
EVO EVO EVO EVO EVO EVO EVO EVO
Art. no. Indoor unit 314100 314101 313325 314102 314103 314104 314105 314106
Art. no. Panel unit 314034 314034 314034 314034 314034 314034 314034 314034
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 80 90 75 82 160 170
Current A 0,40 0,50 0,70 0,80
Heating capacity kW 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,0
Power Input W 80 90 75 82 160 170
Current A 0,40 0,50 0,70 0,80
1.800/
1.157/
$LUʿRZ KLPHGORZ m3/h 847/766/640 864/755/658 1.540/1.300/1.120 1.500/
955/749
1.280
Sound pressure level (hi/med/low) dB(A) 42/38/35 45/42/39 48/45/43 50/47/44
Dimension (LxWxH) mm 840x840x230 840x840x300
Unit Packing (LxWxH) mm 955x955x247 955x955x317
Net/gross weight kg 24/28 26/30 32/37
Dimension (LxWxH) mm 950x950x46
Panel Packing (LxWxH) mm 1.000x1.000x60
Net/gross weight kg 6/8
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 32
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


52 | VRF Ceiling/Floor indoor units

Ceiling and Floor Indoor Units


SYSVRF CEILING
Features

Flexible vertical or horizontal installation, even into a


corner of the ceiling. Infrared remote
control
Even and smooth air distribution due to auto horizontal SYSCONTROL
RM 02
and auto vertical swing function.
(standard)
 :LGHDQJOHDLUʿRZ
Low noise operation.
 :DVKDEOHDLUʾOWHUHDV\IRULQVHUWLRQDQGUHPRYDO
Built-in electronic expansion valve (EXV) ensuring
 SUHFLVHʿRZFRQWURO Wired
controller
Infrared receiver and remote SYSCONTROL RM 02
SYSCONTROL
with address setting function as standard equipment. WC 90
(optional)

Accessories/option
Wired
controller
Wired controller SYSCONTROL WC 90 with address
SYSCONTROL
setting function for heat pump system. WC 120
Wired controller SYSCONTROL WC 120 for heat (optional)

recovery system.

Dimensions

SYSVRF CEILING 36/45/56/71 Q SYSVRF CEILING 112/140 Q

995

906,5 1670
35 1542,3
198,2
39,5 724,5 630,5 235
401 371 112,5
69,5
133,5
98

175

144
184,5
255,2
207

200

655

675

SYSVRF CEILING 90 Q

1284,5
1194,5
547 515
198,2
39,5
37
133,5
98

175 200
655
VRF Ceiling/Floor indoor units | 53

Technical features

CEILING CEILING CEILING CEILING CEILING CEILING CEILING


Model Indoor unit SYSVRF
36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
Art. no. 314116 314117 314118 314119 314120 314121 314122
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 49 120 122 125 130 182
Current A 0,55 0,57 0,60 0,83
Heating capacity kW 4,0 5,0 6,3 8,0 10,0 12,5 15,5
Power Input W 49 120 122 125 130 182
Current A 0,55 0,57 0,60 0,83
650/ 1.200/
$LUʿRZ KLPHGORZ m /h
3
800/600/500 1.980/1.860/1.730
570/500 900/700
Sound pressure level (hi/med/low) dB(A) 40/38/36 43/41/38 45/43/40 47/45/42
1.280x
Dimension (LxWxH) mm 990x206x660 1.670x244x680
206x660

1.379x
Packing (LxWxH) mm 1.089x296x744 1.764x329x760
296x744
Net/gross weight kg 26/32 28/34 34,5/41 54/59
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


54 | VRF Duct indoor units

Medium Static Pressure Duct Indoor Units


SYSVRF DUCT
Features

External static pressure up to 100 Pa.


 :DVKDEOHDLUʾOWHUSODFHGLQDQDOXPLQXPIUDPHZKLFK
is removable downward from the bottom.
 )UHVKDLUKROHDLULQOHWRXWOHWʿDQJHDUHVWDQGDUGIRU
easy duct connection.
Air inlet from back as standard and from bottom as
 RSWLRQDOZLWKWKHVDPHʿDQJHSODWH
Integrated drain pump with a head of 750 mm.
Wired Infrared
 (OHFWURQLFH[SDQVLRQYDOYH (;9 ʾ[HGLQVLGHRIWKH controller remote control
indoor unit. SYSCONTROL SYSCONTROL
WC 90 RM 02
Standard functional port such as remote on/off free (standard) (optional)
contact.
Display board with infrared receiver as standard
Wired
equipment. controller
Wired controller SYSCONTROL WC 90 with address SYSCONTROL
WC 120
setting function as standard equipment. (optional)

Accessories/option

Infrared controller SYSCONTROL RM 02 with address Wired controller SYSCONTROL WC 120 for heat
setting function for heat pump system. recovery system.

DUCT DUCT DUCT DUCT DUCT


Dimensions Indoor unit SYSVRF
22 Q 28 Q 36 Q 45 Q 56 Q
A mm 700 700 700 920 920
B mm 210 210 210 210 210
H

C mm 635 635 635 635 635


D mm 570 570 570 570 570
I

E mm 65 65 65 65 65
F mm 493 493 493 713 713
F G G mm 35 35 35 35 35
A H mm 119 119 119 119 119
E
DUCT DUCT DUCT DUCT
Indoor unit SYSVRF
71 Q 90 Q 112 Q 140 Q
A mm 920 1.140 1.140 1.200
B mm 270 270 270 300
C mm 635 775 775 865
D mm 570 710 710 800
D E mm 65 65 65 80

C
F mm 713 933 933 993
G mm 35 35 35 40
H mm 179 179 179 204
VRF Duct indoor units | 55

Technical features

DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT DUCT


Model Indoor unit SYSVRF
22 Q 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q
Art. no. 314107 314108 314109 314110 314111 314112 314113 314114 314115
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0
Power Input W 59 57 61 92 149 200 313 274
Current A 0,28 0,50 0,70 1,00 1,80
Heating capacity kW 2,6 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,5
Power Input W 59 57 61 92 149 200 313 274
Current A 0,28 0,50 0,70 1,16 1,65 1,80
1400/ 2010/ 2030/
1207/
$LUʿRZ KLPHGORZ m3/h 570/410/320 958/667/583 1018/ 1552/ 1539/
905/821
861 1389 1250
42/ 45/ 47/ 50/ 50/
Sound pressure level (hi/med/low) dB(A) 40/35/32 43/38,9/36
38/36 40/36 39,8/37 41,9/38 43,2/39
20 40 40
External static pressure Pa 10 (10~30)
(10~50) (10~80) (10~100)
Ǹ Ǹ
Dimension (LxWxH) mm ǸǸ ǸǸ ǸǸ
Ǹ Ǹ
Ǹ Ǹ
Packing (LxWxH) mm ǸǸ ǸǸ ǸǸ
Ǹ Ǹ
Net/gross weight kg 21,5/26 22/27 27/32 30/34 40/48 49/58
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 32
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28

Fan performance
SYSVRF DUCT 22/28/36 Q SYSVRF DUCT 45/56 Q SYSVRF DUCT 71 Q
80 80 80

70 70 70

60 Super high 60 60
speed

High
50 speed 50 Super high 50 Super high
External static pressure (Pa)

External static pressure (Pa)

External static pressure (Pa)

speed speed

Medium
40 speed 40 High
40 High
speed speed

30 Low
30 Medium
30 Medium
speed speed speed

20 20 Low
20 Low
speed speed

10 10 10

200 400 600 800 420 600 800 1000 1200 630 800 1000 1200 1400
280
Air flow (m 3/h) Air flow (m 3/h) Air flow (m 3/h)

SYSVRF DUCT 90 Q SYSVRF DUCT 112 Q SYSVRF DUCT 140 Q


110 220 220

100 200 200

90 180 180

80 160 160

Super high Super high Super high


70 speed 140 speed 140 speed
External static pressure (Pa)

External static pressure (Pa)

External static pressure (Pa)

High High
60 120 speed 120 speed
High
speed
50 100 100
Medium Medium
speed speed
Medium
40 speed 80 80
Low Low
speed speed
Low
30 speed 60 60

20 40 40

10 20 20

770800 1000 1200 1400 1000 1400 1800 2200 10601000 1400 1800 2200
1020
Air flow (m 3/h) Air flow (m 3/h) Air flow (m 3/h)

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C 8m 0m

The sound pressure value may vary depending on ambient conditions.


56 | VRF Duct HP indoor units

High Static Pressure Duct Indoor Units


SYSVRF DUCT HP
Features

External static pressure up to 250 Pa.


 :DVKDEOHDLUʾOWHUSODFHGLQDQDOXPLQXPIUDPHZKLFK
is removable downward from the bottom. Easy access
both in rear and bottom.
 )UHVKDLUKROHDLULQOHWRXWOHWʿDQJHDUHVWDQGDUGIRU
easy duct connection.
 (OHFWURQLFH[SDQVLRQYDOYH (;9 ʾ[HGLQVLGHRIWKH
indoor unit.
Display board with infrared receiver as standard Wired Infrared
equipment. controller remote control
SYSCONTROL SYSCONTROL
Wired controller SYSCONTROL WC 90 with address WC 90 RM 02
setting function as standard equipment. (standard) (optional)

Accessories/option Wired
controller
SYSCONTROL
Infrared remote SYSCONTROL RM 02 with address WC 120
(optional)
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.

Dimensions

SYSVRF DUCT HP 71/112 Q SYSVRF DUCT HP 140 Q


952
856 135 930 88
86
29

214
56
82

82
85

249

270
420
420

Plastic
cover
Plastic
cover
Electrical 68 24
control box 46 Electrical
control box

SYSVRF DUCT HP 200/280 Q


936 200
1121 75
60
96

378
343

50
VRF Duct HP indoor units | 57

Technical features

Model Indoor unit SYSVRF DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q
Art. no. 314129 314130 314131 314132 314133
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 7,1 11,2 14,0 20,0 28,0
Power Input W 263 524 724 1.516 1.516
Current A 1,1 2,3 2,7 6,6 6,6
Heating capacity kW 8,0 12,5 16,0 22,5 31,5
Power Input W 263 524 724 1.516 1.516
Current A 1,1 2,3 2,7 6,6 6,6
1.510/ 2.117/ 2.988/ 4.268/ 4.400/
$LUʿRZ KLPHGORZ m3/h
1.399/1.236 1.950/1.644 2.670/2.229 3.780/3.200 3.700/3.200
Sound pressure level (hi/med/low) dB(A) 48/46/44 52/49/47 53/50/48 59/55/52 59/55/52
External static pressure Pa 40 (30~196) 50 (30~196) 50 (30~196) 140 (50~250) 160 (50~250)
Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470 1.356x763x470
Packing (LxWxH) mm 1.090x768x440 1.090x768x440 1.436x768x450 1.509x964x570 1.509x964x570
Net/gross weight kg 45/50 50,6/56 68/70 115/129 115/129
Refrigerant R410A
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) (x2) 9,5 (3/8”) (x2)
Piping dimension
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) (x2) 15,9 (5/8”) (x2)
Drain piping mm 32 32 32 32 32
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28

Fan performance
SYSVRF DUCT HP 71 Q SYSVRF DUCT HP 112 Q
P(Pa)
P(Pa)

300
300
280
280
260
260
240
240

220
220

200 200

180 180

160
160
High speed High speed
140 140

120 120
Midium speed
100
Midium speed 100

80 80

60
Low speed Low speed
60

40 40

20 20
0
0
800 1000 1200 1400 1600 1800 2000
400 600 800 1000 1200 1400 1600 1800 2000 2200
Q(m3/h)
3
Q( /h)

SYSVRF DUCT HP 140 Q SYSVRF DUCT HP 200 Q SYSVRF DUCT HP 280 Q


P(Pa)
P(Pa)

P(Pa)

300 300 300

280 280 280

260 260 260

240 240 High speed 240 High speed


220 220 220

200 200 200


Midium speed Midium speed
180 180 180

Low speed
160 160 Low speed 160
High speed
140 140 140

120 120 120

100 Midium speed 100 100

80 80
80
Low speed 60
60 60

40 40
40

20 20
20

0 0
0
2000 2500 3000 3500 4000 4500 5000 5500 6000 2000 2500 3000 3500 4000 4500 5000 5500 6000
400 600 800 1000 1200 1400 1600 1800 2000
Q(m3/h) Q(m3/h) Q(m3/h)

Nominal conditions

Indoor unit Outdoor unit Piping lenght Level difference


Cooling mode 27°C DB, 19°C WB 35°C DB 8m 0m
Heating mode 20°C DB, 15°C WB 7°C DB 8m 0m

The sound pressure value may vary depending on ambient conditions.


58 | VRF Heat Recovery Ventilation

Heat Recovery Ventilation Units


SYSVRF HRV
Features

 &URVVʿRZKHDWH[FKDQJHUPDGHRIVSHFLDOSDSHUIRU
 HQKDQFHGKHDWH[FKDQHJHIʾFLHQF\
Main structure made of galvanized steel sheet.
 +LJKHIʾFLHQWFHQWULIXJDOIDQDVVXUHVORZSRZHU
consumption. SYSVRF HRV 500/1000 Q

3 fan speeds available for sizes 500 m3/h and 1000


m3/h, 1 speed for size 2000 m3/h.
 7HPSHUDWXUHH[FKDQJHHIʾFLHQF\DERYH
 &RPSDFWGHVLJQDQGʿH[LEOHLQVWDOODWLRQLQWKHIDOVHFHLOLQJ
Different operating modes available: heat exchange,
bypass, auto, exhaust/supply mode. SYSVRF HRV 2000 R
Insulation material guarantees quiet operation and
thermal insulation. Wired
7KDQNVWRWKHʿH[LEOHFRQWUROWKH+59XQLWFDQEH controller
SYSCONTROL
interlocked to the operation of the VRF indoor units. WC 27
Wired controller SYSCONTROL WC 27 as standard (standard)

equipment.

Dimensions

SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 R


L W 75
1550
Wire N2
N Door control H
box

W2
C Wire
Door control
box
Air exhaust By-pass Air return
vent system vent

W1 1400

Fresh Air supply


air inlet vent

L1 G
350

326

540

Model SYSVRF HRV 500 Q SYSVRF HRV 1000 Q


L 824 1.116 700

L1 754 1.045 250


1600
W 904 1.134
W1 960 1.190
20

Air supply
W2 500 678 Air exhaust
vent vent

H 270 388
1370

C 107 85 Fresh Air return


air inlet vent
G 19 19 50 50

N Ɗ Ɗ
1650
N2 111 170
VRF Heat Recovery Ventilation | 59

Technical features

Model Indoor unit SYSVRF HRV 500 Q HRV 1000 Q HRV 2000 R
Art. no. 314134 314135 314136
Power supply V/Ph/Hz 220-240/1/50 380/3/50
$LUʿRZUDWH +0/ m3/h 500/500/375 1.000/1.000/750 2.000
External static pressure (H/M/L) Pa 80/68/45 100/85/58 170
Power consumption W 120 360 450
(QWKDOS\H[FKDQJHHIʾFLHQF\
% 50/50/55 50/50/55 50
Cooling (H/M/L)
(QWKDOS\H[FKDQJHHIʾFLHQF\
% 60/60/65 60/60/65 60
Heating (H/M/L)
7HPSHUDWXUHH[FKDQJHHIʾFLHQF\ +0/ % 65/65/70 65/65/70 65

Sound pressure level (H/M/L) dB(A) 35/34/28 40/39/33 53

Dimensions (LxWxH) mm 1.038x1.026x270 1.286x1.256x388 1.650x1.470x540


Unit weight kg 41 79 182
Duct connection dimensions mm ʡ ʡ 346x326
Ambient condition °C -7…+43/ max 80% RH

Fan performance
SYSVRF HRV 500 Q
Air flow (m3/h)

External static pressure (Pa)

SYSVRF HRV 1000 Q


Air flow (m3/h)

External static pressure (Pa)

SYSVRF HRV 2000 Q


Air flow (m3/h)

External static pressure (Pa)

Nominal conditions

Exhaust air Fresh air


Cooling mode 27°C DB, 19,5°C WB 35°C DB, 28°C WB
Heating mode 21°C DB, 13°C WB 5°C DB, 2°C WB

The sound pressure value may vary depending on ambient conditions.


60 | VRF connection to AHU

Connection of SYSVRF AHU


SYSCONTROL AHU
Features

The SYSCONTROL AHU 5HP, 10HP and 20HP can be used


to connect the SYSVRF outdoor units to an external DX
AHU with capacity from 7 kW to 73 kW.

Nominal capacity in cooling 14kW (5HP), 28kW (10HP)


and 56kW (20HP).
Modulating cooling/heating capacity thanks to the
built-in Electronic Expansion Valve (EXV) controlled
by the superheat degree of the AHU.
The SYSCONTROL AHU kit includes four temperature
sensors, one for the air intake of the AHU and three for
a precise monitoring of the DX evaporator coil.
For indoor installation in horizontal or vertical position.
Failure alarm codes on the PCB for quick service checking.
Environment friendly R410A refrigerant.
Connection to Systemair network monitoring system.

Connection diagram

SYSVRF indoor units

SYSVRF
outdoor unit

SYSCONTROL AHU SYSTEMAIR Air Handling Unit

Technical features

Model Indoor unit SYSVRF SYSCONTROL AHU 5HP SYSCONTROL AHU 10HP SYSCONTROL AHU 20HP
Art. no. 314188 314189 314190
Power supply V/Ph/Hz 220-240/1/50, 208-230/1/60
AHU capacity kW 9-20 20-33 40-56
Dimensions (LxWxH) mm 375x350x150
Packing (LxWxH) mm 490x240x420
Piping diameters in/out mm 8/8 12,7/12,7 15,9/15,9
IP-class IP X0 IP X0 IP X0
VRF connection to AHU | 61

SYSVRF selection
and designing software
Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF.

Main tasks:
Calculation of the heat loads and selection of the
necessary cooling /heating capacity, type and location
of outdoor and indoor units.
Calculation of the refrigerant piping diameters and
the required additional amount of refrigerant.
Selection of an optimal set of piping joints.
Building Management System.
Correction of the performance of indoor units.
Automatic check of the circuit for compliance
requirements and limits on the maximum length of
refrigerant pipelines and indoor-outdoor elevations.
&RQFOXVLRQRISURMHFWGRFXPHQWDWLRQVSHFLʾFDWLRQ
([FHO DGHWDLOHGVSHFLʾFDWLRQZLWKWKHGUDZLQJV
(Word), and print out of all documents.
62 | VRF control systems

SYSCONTROL systems
Remote control for indoor units

Wireless infrared remote control SYSCONTROL RM 02


Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner,
temperature setting , fan speed selection (high/medium/low/auto), 24h on/off
WLPHU785%2PRGH(&2PRGHDLUʿRZVZLQJDGMXVWPHQWGLVSOD\EDFNOLJKWEXWWRQ
FOLLOW ME functions, keyboard locking function, 26 °C button.
Standard equipment for SYSVRF WALL, CASSETTE, CEILING. For 2-pipe and 3-pipe
SYSVRF. (Art. no. 314138).

Wired controller SYSCONTROL WC 90


Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner,
temperature setting, fan speed selection (high/medium,low/auto), real 24h on/off
timer, swing button.
Standard equipment for SYSVRF DUCT, DUCT HP. Designed for 2-pipe SYSVRF HP with
automatic cooling/heating changeover. It can be used for 3-pipe SYSVRF HR with
manual cooling/heating changeover. (Art. no. 314139).

Wired controller SYSCONTROL WC 120


Main functions: on/off, cool/heat/auto/dry/fan mode of the air conditioner,
temperature setting , fan speed selection (high/medium/low/auto), 24h on/off timer,
DLUʿRZVZLQJDGMXVWPHQWDLUʾOWHUIXQFWLRQNH\ERDUGORFNLQJEXWWRQ
2SWLRQDO HTXLSPHQW IRU DOO VHULHV RI 6<695) LQGRRU XQLWV 6SHFLʾFDOO\ GHVLJQHG IRU
3-pipe SYSVRF HR systems with automatic cooling/heating changeover and adjustable
dead band. It can be used in 2-pipe SYSVRF HP systems. (Art. no. 314182).

Centralized controllers

Centralized controller SYSCONTROL CWC 03 HP/HR


Monitors and manages 64 indoor units. Main functions: on/off, setting modes
(including the lock mode), change temperature settings, fan speed selection, query
function and error code of indoor units LCD with backlight. Provides the ability to
connect to a PC via a converter RS485/RS232.
(Art. no. 314140) CWC 03 HP for 2-pipe SYSVRF HP.
(Art. no. 314183) CWC 03 HR for 3-pipe SYSVRF HR.

Centralized controller SYSCONTROL CWC 09


Monitors and manages 64 indoor units. Perform the same functions of the central
control SYSCONTROL CWC 03, with the possibility of drawing up management program
for the week. LCD with backlight it doesn't have the port for the connection to a PC.
(Art. no. 314141).

Centralized monitoring of outdoor units SYSCONTROL CWC 02


Monitors up to 32 outdoor units which may be included in the 8 different VRF air
conditioning systems. When using a powermeter tra performs the accounting function
of electricity consumed. Ability to connect to a PC via a converter RS485/RS232. (Art.
no. 314142).
VRF control systems | 63

Intelligent Network Management System


Systemair multi-zone system can be integrated into a comprehensive building management system (BMS) thanks to the
Bacnet, Modbus or LonWorks gateway via SYSCONTROL CWC 08/CWC 11/CWC 64, respectively.
With the implementation of these gateway it is possible to use different control schemes: individual, group, network.
To one gateway Bacnet SYSCONTROL CWC 08 (Art. no. 314145) can be connected to up to 4 remote central control
(SYSCONTROL CWC 02 /SYSCONTROL CWC 03). Each group can contain a maximum of 64 indoor units/32 outdoor units.
Bacnet

SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120

SYSCONTROL
BMS CWC 03

SYSCONTROL
SYSCONTROL CWC 03
CWC 08

SYSCONTROL
CWC 03

S SCO RO
SYSCONTROL
CWC 02

The central management console (SYSCONTROL CWC 03) can be connected to one gateway Modbus SYSCONTROL CWC 11
(Art. no. 314143). Each group can contain a maximum of 64 indoor units.

Modbus

BMS

SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120

SYSCONTROL CWC 11
SYSCONTROL
CWC 03

Up to 64 indoor units can be directly connected to one gateway Lonworks SYSCONTROL CWC 64 (Art. no. 314144).

LonWorks

BMS

SYSCONTROL RM 02 SYSCONTROL WC 90/WC 120

SYSCONTROL CWC 64
64 | VRF piping joint

Piping joints for 2-pipe refrigerant system


SYSVRF JOINT

Outdoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series

Indoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 2P 314149 290x105x100 0,4 &DSDFLW\RIFRQQHFWHGLQGRRUXQLWVN:
SYSVRF JOINT IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units 92-135kW
SYSVRF JOINT IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units > 135kW
VRF piping joint | 65

Piping joints for 3-pipe refrigerant system


SYSVRF JOINT

Outdoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HR 314155 272×167×232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 03 HR 314156 472×157×312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 04 HR 314184 745×160×335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series

Indoor unit

Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 3P 314157 257×127×107 0,8 &DSDFLW\RIFRQQHFWHGLQGRRUXQLWVN:
SYSVRF JOINT IN 02 3P 314158 287×137×107 0,9 Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 3P 314159 297×167×177 1,4 Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 3P 314160 372×197×187 2,3 Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 3P 314185 432×222×227 3,3 Capacity of connected indoor units > 92kW
Notes
www.systemair.com