Professional Documents
Culture Documents
SYSVRF
VRF systems | 31
&RQWLQXRXVGHYHORSPHQWLQWKHʾHOGRIPDQDJHPHQW
In modern air-conditioning systems the demand for
automation and control systems integrated with other
infrastructure building systems is continuously increasing.
These are exactly the principles on the basic of the
development of the control systems of Systemair.
In addition to the traditional control systems of air
conditioning, the user deals with different possibilities of
The most comfortable temperature control that can solve the various needs of the building
An important advantage of the multi-zone air-conditioning management such as the possibility of control via
is a smooth and rapid achievement of a comfortable personal computer and Internet network connection.
WHPSHUDWXUHDVZHOODVPDLQWDLQLQJWKHVSHFLʾHG
parameters accurate to ± 0,5 °C. Such high performance Simplicity of design
was achieved thanks to an accurate control of the Systemair provides full integration and coordination of
UHIULJHUDQWʿRZDQGWKHPHFKDQLVPRIUHGLVWULEXWLRQRI DOOHOHPHQWVRIDPXOWL]RQHV\VWHPJUHDWO\VLPSOLʾHV
refrigerant between the several units, implemented with the task of the designer. The selection process can be
the help of electronic expansion valves. performed in maximum short period of time by using a
simple and complete selection and designing software.
+LJKHQHUJ\HIʾFLHQF\
7KHHIʾFLHQF\RIPXOWL]RQHV\VWHPVLVYHU\KLJKEHFDXVH
each time the electric power is consumed as much as
necessary to carry out user requirements.
If the indoor units work only in a few areas of the building,
then the power consumption is reduced proportionally by
FKDQJLQJWKHUHIULJHUDQWʿRZ
Low noise
Low noise of both outdoor and indoor units makes the job
a multizone system virtually inconspicuous.
VRF systems | 33
SYSVRF lineup
In 2014 Systemair has launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of
work lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the
high standards set by the industry.
7KURXJKWKHXVHRIPRGHUQWHFKQRORJLHVDQGLPSOHPHQWDWLRQRIWKHLURZQGHYHORSPHQWKDVVLJQLʾFDQWO\LPSURYHGHQHUJ\
HIʾFLHQF\ DQG GHFUHDVHG WKH QRLVH OHYHO ZLWK FRPSDFW GLPHQVLRQV LQFUHDVHG HDVH RI LQVWDOODWLRQ DQG PDLQWHQDQFH
greatly expanded the range of application from light commercial to large commercial spaces.
1,5-5,6 kW 3,6-14,0 kW
SYSVRF Indoor units
2,2-5,6 kW 2,8-14,0 kW
2,2-14,0 kW 7,1-28,0 kW
Dimensions
H
A
Model 120 140 160
A 900 900 900
B B 600 600 600
C 348 348 348
D 320 320 320
E 400 400 400
E
D
F
C
Technical features
Model Indoor unit SYSVRF 120 AIR EVO HP Q 140 AIR EVO HP R 160 AIR EVO HP R
Art. no. 314089 314092 314094
Power Supply V/Ph/Hz 220-240/1/50 380-415/3/50
Cooling capacity kW 12,3 14,0 15,5
Power Input kW 3,25 3,95 4,52
EER 3,78 3,54 3,43
Heating capacity kW 13,2 15,4 17,0
Power Input kW 3,47 4,16 4,77
COP 3,80 3,70 3,56
Max. current A 36 12
Quantity pcs 1
Compressor
Power Input W 3.010 3.010 4.240
Inverter Rotary
Refrigerant oil ml 870+630 870+630 1.400+250
$LUʿRZ m3/h 6.000
Sound pressure level dB(A) 57
Type R410A
Refrigerant
Refrigerant charge kg 3,3 3,9 3,9
Dimension LxWxH mm 900x320x1.327
Packing LxWxH mm 1.030x435x1.456
Net/gross weight kg 95/106 95/106 102/113
Liquid pipe mm (in) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 15,9 (5/8”)
Max qty. indoor units connection pcs 6 6 7
Operating ambient temp. range °C Cooling -15 ... +48 / Heating -15 ... +27
Nominal conditions
Piping Lenght
Dimensions
SYSVRF 252/280 AIR EVO HP R SYSVRF 335/400/450/500 AIR EVO HP R
1250
1615
1615
960
765
765
VRF Heat Pump | 37
Technical features
252 AIR 280 AIR 335 AIR 400 AIR 450 AIR 500 AIR
Model Indoor unit SYSVRF
EVO HP R EVO HP R EVO HP R EVO HP R EVO HP R EVO HP R
Art. no. 314078 314079 314080 314081 314082 314083
Power Supply V/Ph/Hz 380-415/3/50
Cooling capacity kW 25,2 28,0 33,5 40,0 45,0 50,0
Power Input kW 5,88 7,20 9,05 12,31 14,02 15,20
EER 4,29 3,89 3,7 3,25 3,21 3,29
Heating capacity kW 27,0 31,5 37,5 45,0 50,0 56,0
Power Input kW 6,15 7,61 8,99 11,19 12,79 14,25
COP 4,39 4,14 4,17 4,02 3,91 3,93
Max. current A 20,8 22,1 23,7 31,8 32,8 35,4
Quantity pcs 1
Compressor
Capacity W 31.590 31.590 11.800 31.590 31.590 31.590
Inverter Scroll
Refrigerant oil ml 500 500 500 500 500 500
Quantity pcs - - 1 1 1 1
Compressor
Capacity W - - 17.100 13.390 13.390 20.900
Fixed Scroll
Refrigerant oil ml - - 500 500 500 500
$LUʿRZ m3/h 11.500 15.100 15.600 15.600 15.600
Sound pressure level dB(A) 57 59 60 61
Type R410A
Refrigerant
Refrigerant charge kg 9 11 13 16
Dimension (LxWxH) mm 960x765x1.615 1.250x765x1.615
Packing (LxWxH) mm 1.025x830x1.790 1.305x825x1.790
Net/gross weight kg 198/213 266/288 280/300 300/320
Liquid pipe mm (in) 12,7 (1/2”) 15,9 (5/8”) 19,1 (3/4”)
Piping dimension Gas pipe mm (in) 25,4 (1”) 31,8 (1 1/4”) 31,8 (1 1/4”)
Oil balance pipe mm (in) 6,35 (1/4”)
Operating ambient temp. range °C Cooling -5 ... +48 / Heating -20 ... +24
Nominal conditions
Piping Lenght
0D[LPXPSLSLQJWKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW
branch) equivalent lenght.
:KHQWKHIDUWKHVWSLSHOHQJWKLVPRUHWKDQPLWQHHGVWRPHHWVSHFLʾFFRQGLWLRQVDFFRUGLQJWRWKHLQVWDOODWLRQSDUWRIWKHWHFKQLFDOPDQXDO
** Level difference: less or equal to 50m is standard; more than 50m is available to be customized.
38 | VRF Heat Pump combination
SYSVRF JOINT
56/63 SYSVRF 560 AIR EVO HP R SYSVRF 280 AIR EVO HP R x2 33
OUT 02 HP
SYSVRF JOINT
100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 59
OUT 02 HP
VRF Heat Pump combination | 39
Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty
SYSVRF JOINT
120/135 SYSVRF 1200 AIR EVO HP R SYSVRF 400 AIR EVO HP R x3 64
OUT 03 HP
SYSVRF JOINT
150/168 SYSVRF 1500 AIR EVO HP R SYSVRF 500 AIR EVO HP R x3 64
OUT 03 HP
SYSVRF JOINT
200/224 SYSVRF 2000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x 4 64
OUT 04 HP
40 | VRF Heat Recovery
Dimensions
SYSVRF 252/280/335/400/450 AIR EVO HR R
1250
1615
765
VRF Heat Recovery | 41
Technical features
252 AIR EVO 280 AIR EVO 335 AIR EVO 400 AIR EVO 450 AIR EVO
Model Indoor unit SYSVRF
HR R HR R HR R HR R HR R
Art. no. 314084 314085 314086 314087 314088
Power Supply V/Ph/Hz 380-415/3/50, 380-415/3/60
Cooling capacity kW 25,2 28,0 33,5 40,0 45,0
Power Input kW 5,73 6,67 8,07 11,30 13,24
EER 4,40 4,20 4,15 3,54 3,40
Heating capacity kW 27,0 31,5 37,5 45,0 50,0
Power Input kW 6,00 7,33 8,72 11,19 12,79
COP 4,50 4,30 4,30 4,02 3,91
Max. current A 20,8 22,1 22,8 31,8 32,8
Quantity pcs 1 1 1 2 2
Compressor
Capacity W 31.590 31.590 31.590 31.590+11.800
Inverter Scroll
Refrigerant oil ml 500 500 500 500+500
$LUʿRZ m3/h 12.000 12.000 13.000 15.000 15.000
Sound pressure level dB(A) 57 58 60 60
Type R410A
Refrigerant
Refrigerant charge kg 10 10 10 14
Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615
Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790
Net/gross weight kg 255/273 303/322
Liquid pipe mm (in) 9,5 (3/8”) 12,7 (1/2”) 12,7 (1/2”) 15,9 (5/8”) 15,9 (5/8”)
Low pressure gas pipe mm (in) 22,2 (7/8”) 22,2 (7/8”) 25,4 (1”) 28,6 (1 1/8”) 28,6 (1 1/8”)
Piping dimension High pressure gas pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”)
Oil balance pipe mm (in) 19,1 (3/4”) 19,1 (3/4”) 19,1 (3/4”) 22,2 (7/8”) 22,2 (7/8”)
Gas balance pipe mm (in) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”) 6,0 (1/4”)
Operating ambient temp. range °C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24
Nominal conditions
Piping Lenght
0D[LPXPSLSLQJWKHIDUWKHVW,'8IURPWKHʾUVWLQGRRUXQLW
branch) equivalent lenght.
:KHQWKHIDUWKHVWSLSHOHQJWKLVPRUHWKDQPLWQHHGVWRPHHWVSHFLʾFFRQGLWLRQVDFFRUGLQJWRWKHLQVWDOODWLRQSDUWRIWKHWHFKQLFDOPDQXDO
** Level difference: less or equal to 50m is standard; more than 50m is available to be customized.
42 | VRF Heat Recovery switch module
Technical features
SYSVRF JOINT
56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 33
OUT 02 HR
SYSVRF JOINT
80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 46
OUT 02 HR
SYSVRF JOINT
90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 53
OUT 02 HR
VRF Heat Recovery combination | 45
Cooling/ Max.
Recommended Outdoor
Design Heating Model indoor
combination branch
capacity kW unit qty
SYSVRF JOINT
120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 64
OUT 03 HR
SYSVRF JOINT
135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 64
OUT 03 HR
SYSVRF JOINT
180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 64
OUT 04 HR
46 | VRF Wall indoor units
)URQWSDQHORIPRGHUQGHVLJQWKDWʾWVLQWRDQ\
interior decor.
Even and smooth air distribution due to auto swing
function.
Multi-refrigerant outlet pipe method: left/right/rear,
more flexible for installation.
Washable air filter, easy for insertion and removal.
Built-in electronic expansion valve (EXV) ensuring
SUHFLVHʿRZFRQWURO
Infrared receiver and remote SYSCONTROL RM 02 Infrared remote Wired
control controller
with address setting function as standard equipment.
SYSCONTROL SYSCONTROL
RM 02 WC 90
(standard) (optional)
Accessories/option
Dimensions
B
A
C
Technical features
Model Indoor unit SYSVRF WALL 15 Q WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q
Art. no. 314123 314124 314125 314126 314127 314128
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 1,5 2,2 2,8 3,6 4,5 5,6
Power Input W 28 45
Current A 0,14 0,20 0,33
Heating capacity kW 1,7 2,4 3,2 4,0 5,0 6,3
Power Input W 28 45
Current A 0,14 0,20
$LUʿRZKLPHGORZ m3/h 525/480/430 590/520/480 860/755/830 925/860/755
Sound pressure level (hi/med/low) dB(A) 35/32/29 40/38/34
Dimension (LxWxH) mm 915x230x290 1.072x230x315
Packing (LxWxH) mm 1.020x315x390 1.180x315x415
Net/gross weight kg 13/16,5 15,1/18,8
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (1/4”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16,5
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28
Nominal conditions
Dimensions
Hook
647 (panel)
Main body
523
570
260
Nut
50
Ceiling 600 Panel
545
570
647 (panel)
VRF Compact Cassette indoor units | 49
Technical features
CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI
Model Indoor unit SYSVRF
22 Q 28 Q 36 Q 45 Q 56 Q
CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI CASSETTE MINI
Model Panel unit SYSPANEL
VRF VRF VRF VRF VRF
Art. no. Indoor unit 314095 314096 314097 314098 314099
Art. no. Panel unit 313324 313324 313324 313324 313324
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 2,2 2,8 3,6 4,5 5,6
Power Input W 48 48 56
Current A 0,175 0,21
Heating capacity kW 2,4 3,2 4,0 5,0 6,0
Power Input W 48 56
Current A 0,175 0,21
$LUʿRZKLPHGORZ m3/h 522/414/313 610/521/409
Sound pressure level (hi/med/low) dB(A) 35,8/33,4/23,4 41,5/35,6/28,8
Dimension (LxWxH) mm 570x570x260
Unit Packing (LxWxH) mm 675x675x285
Net/gross weight kg 17,5/22 19/23,5
Dimension (LxWxH) mm 647x675x50
Panel Packing (LxWxH) mm 705x705x113
Net/gross weight kg 3/5
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3,8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 25
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28
Nominal conditions
Dimensions
950
780 105 Φ32 Drain pipe
A outter diameter 70
≥20
55
950
680
840
146
Ceiling 46
Panel
Main body
B 840
Φ75 New air
supply orifice 904
Technical features
Nominal conditions
Accessories/option
Wired
controller
Wired controller SYSCONTROL WC 90 with address
SYSCONTROL
setting function for heat pump system. WC 120
Wired controller SYSCONTROL WC 120 for heat (optional)
recovery system.
Dimensions
995
906,5 1670
35 1542,3
198,2
39,5 724,5 630,5 235
401 371 112,5
69,5
133,5
98
175
144
184,5
255,2
207
200
655
675
SYSVRF CEILING 90 Q
1284,5
1194,5
547 515
198,2
39,5
37
133,5
98
175 200
655
VRF Ceiling/Floor indoor units | 53
Technical features
1.379x
Packing (LxWxH) mm 1.089x296x744 1.764x329x760
296x744
Net/gross weight kg 26/32 28/34 34,5/41 54/59
Refrigerant R410A
Liquid pipe mm (in) 6,4 (1/4”) 9,5 (3/8”)
Piping dimension
Gas pipe mm (in) 12,7 (1/2”) 15,9 (5/8”)
Drain piping mm 16
Operating ambient temp. range °C Cooling +17...+32 / Heating +10...+28
Nominal conditions
Accessories/option
Infrared controller SYSCONTROL RM 02 with address Wired controller SYSCONTROL WC 120 for heat
setting function for heat pump system. recovery system.
E mm 65 65 65 65 65
F mm 493 493 493 713 713
F G G mm 35 35 35 35 35
A H mm 119 119 119 119 119
E
DUCT DUCT DUCT DUCT
Indoor unit SYSVRF
71 Q 90 Q 112 Q 140 Q
A mm 920 1.140 1.140 1.200
B mm 270 270 270 300
C mm 635 775 775 865
D mm 570 710 710 800
D E mm 65 65 65 80
C
F mm 713 933 933 993
G mm 35 35 35 40
H mm 179 179 179 204
VRF Duct indoor units | 55
Technical features
Fan performance
SYSVRF DUCT 22/28/36 Q SYSVRF DUCT 45/56 Q SYSVRF DUCT 71 Q
80 80 80
70 70 70
60 Super high 60 60
speed
High
50 speed 50 Super high 50 Super high
External static pressure (Pa)
speed speed
Medium
40 speed 40 High
40 High
speed speed
30 Low
30 Medium
30 Medium
speed speed speed
20 20 Low
20 Low
speed speed
10 10 10
200 400 600 800 420 600 800 1000 1200 630 800 1000 1200 1400
280
Air flow (m 3/h) Air flow (m 3/h) Air flow (m 3/h)
90 180 180
80 160 160
High High
60 120 speed 120 speed
High
speed
50 100 100
Medium Medium
speed speed
Medium
40 speed 80 80
Low Low
speed speed
Low
30 speed 60 60
20 40 40
10 20 20
770800 1000 1200 1400 1000 1400 1800 2200 10601000 1400 1800 2200
1020
Air flow (m 3/h) Air flow (m 3/h) Air flow (m 3/h)
Nominal conditions
Accessories/option Wired
controller
SYSCONTROL
Infrared remote SYSCONTROL RM 02 with address WC 120
(optional)
setting function for heat pump system.
Wired controller SYSCONTROL WC 120 for heat
recovery system.
Dimensions
214
56
82
82
85
249
270
420
420
Plastic
cover
Plastic
cover
Electrical 68 24
control box 46 Electrical
control box
378
343
50
VRF Duct HP indoor units | 57
Technical features
Model Indoor unit SYSVRF DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q
Art. no. 314129 314130 314131 314132 314133
Power Supply V/Ph/Hz 220-240/1/50
Cooling capacity kW 7,1 11,2 14,0 20,0 28,0
Power Input W 263 524 724 1.516 1.516
Current A 1,1 2,3 2,7 6,6 6,6
Heating capacity kW 8,0 12,5 16,0 22,5 31,5
Power Input W 263 524 724 1.516 1.516
Current A 1,1 2,3 2,7 6,6 6,6
1.510/ 2.117/ 2.988/ 4.268/ 4.400/
$LUʿRZKLPHGORZ m3/h
1.399/1.236 1.950/1.644 2.670/2.229 3.780/3.200 3.700/3.200
Sound pressure level (hi/med/low) dB(A) 48/46/44 52/49/47 53/50/48 59/55/52 59/55/52
External static pressure Pa 40 (30~196) 50 (30~196) 50 (30~196) 140 (50~250) 160 (50~250)
Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470 1.356x763x470
Packing (LxWxH) mm 1.090x768x440 1.090x768x440 1.436x768x450 1.509x964x570 1.509x964x570
Net/gross weight kg 45/50 50,6/56 68/70 115/129 115/129
Refrigerant R410A
Liquid pipe mm (in) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) 9,5 (3/8”) (x2) 9,5 (3/8”) (x2)
Piping dimension
Gas pipe mm (in) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) 15,9 (5/8”) (x2) 15,9 (5/8”) (x2)
Drain piping mm 32 32 32 32 32
Operating ambient temp. range °C Cooling +17…+32 / Heating +10…+28
Fan performance
SYSVRF DUCT HP 71 Q SYSVRF DUCT HP 112 Q
P(Pa)
P(Pa)
300
300
280
280
260
260
240
240
220
220
200 200
180 180
160
160
High speed High speed
140 140
120 120
Midium speed
100
Midium speed 100
80 80
60
Low speed Low speed
60
40 40
20 20
0
0
800 1000 1200 1400 1600 1800 2000
400 600 800 1000 1200 1400 1600 1800 2000 2200
Q(m3/h)
3
Q( /h)
P(Pa)
Low speed
160 160 Low speed 160
High speed
140 140 140
80 80
80
Low speed 60
60 60
40 40
40
20 20
20
0 0
0
2000 2500 3000 3500 4000 4500 5000 5500 6000 2000 2500 3000 3500 4000 4500 5000 5500 6000
400 600 800 1000 1200 1400 1600 1800 2000
Q(m3/h) Q(m3/h) Q(m3/h)
Nominal conditions
&URVVʿRZKHDWH[FKDQJHUPDGHRIVSHFLDOSDSHUIRU
HQKDQFHGKHDWH[FKDQHJHIʾFLHQF\
Main structure made of galvanized steel sheet.
+LJKHIʾFLHQWFHQWULIXJDOIDQDVVXUHVORZSRZHU
consumption. SYSVRF HRV 500/1000 Q
equipment.
Dimensions
W2
C Wire
Door control
box
Air exhaust By-pass Air return
vent system vent
W1 1400
L1 G
350
326
540
Air supply
W2 500 678 Air exhaust
vent vent
H 270 388
1370
N Ɗ Ɗ
1650
N2 111 170
VRF Heat Recovery Ventilation | 59
Technical features
Model Indoor unit SYSVRF HRV 500 Q HRV 1000 Q HRV 2000 R
Art. no. 314134 314135 314136
Power supply V/Ph/Hz 220-240/1/50 380/3/50
$LUʿRZUDWH+0/ m3/h 500/500/375 1.000/1.000/750 2.000
External static pressure (H/M/L) Pa 80/68/45 100/85/58 170
Power consumption W 120 360 450
(QWKDOS\H[FKDQJHHIʾFLHQF\
% 50/50/55 50/50/55 50
Cooling (H/M/L)
(QWKDOS\H[FKDQJHHIʾFLHQF\
% 60/60/65 60/60/65 60
Heating (H/M/L)
7HPSHUDWXUHH[FKDQJHHIʾFLHQF\+0/ % 65/65/70 65/65/70 65
Fan performance
SYSVRF HRV 500 Q
Air flow (m3/h)
Nominal conditions
Connection diagram
SYSVRF
outdoor unit
Technical features
Model Indoor unit SYSVRF SYSCONTROL AHU 5HP SYSCONTROL AHU 10HP SYSCONTROL AHU 20HP
Art. no. 314188 314189 314190
Power supply V/Ph/Hz 220-240/1/50, 208-230/1/60
AHU capacity kW 9-20 20-33 40-56
Dimensions (LxWxH) mm 375x350x150
Packing (LxWxH) mm 490x240x420
Piping diameters in/out mm 8/8 12,7/12,7 15,9/15,9
IP-class IP X0 IP X0 IP X0
VRF connection to AHU | 61
SYSVRF selection
and designing software
Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF.
Main tasks:
Calculation of the heat loads and selection of the
necessary cooling /heating capacity, type and location
of outdoor and indoor units.
Calculation of the refrigerant piping diameters and
the required additional amount of refrigerant.
Selection of an optimal set of piping joints.
Building Management System.
Correction of the performance of indoor units.
Automatic check of the circuit for compliance
requirements and limits on the maximum length of
refrigerant pipelines and indoor-outdoor elevations.
&RQFOXVLRQRISURMHFWGRFXPHQWDWLRQVSHFLʾFDWLRQ
([FHODGHWDLOHGVSHFLʾFDWLRQZLWKWKHGUDZLQJV
(Word), and print out of all documents.
62 | VRF control systems
SYSCONTROL systems
Remote control for indoor units
Centralized controllers
SYSCONTROL
BMS CWC 03
SYSCONTROL
SYSCONTROL CWC 03
CWC 08
SYSCONTROL
CWC 03
S SCO RO
SYSCONTROL
CWC 02
The central management console (SYSCONTROL CWC 03) can be connected to one gateway Modbus SYSCONTROL CWC 11
(Art. no. 314143). Each group can contain a maximum of 64 indoor units.
Modbus
BMS
SYSCONTROL CWC 11
SYSCONTROL
CWC 03
Up to 64 indoor units can be directly connected to one gateway Lonworks SYSCONTROL CWC 64 (Art. no. 314144).
LonWorks
BMS
SYSCONTROL CWC 64
64 | VRF piping joint
Outdoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series
SYSVRF JOINT OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series
Indoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 2P 314149 290x105x100 0,4 &DSDFLW\RIFRQQHFWHGLQGRRUXQLWVN:
SYSVRF JOINT IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units 92-135kW
SYSVRF JOINT IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units > 135kW
VRF piping joint | 65
Outdoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT OUT 02 HR 314155 272×167×232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 03 HR 314156 472×157×312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series
SYSVRF JOINT OUT 04 HR 314184 745×160×335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series
Indoor unit
Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use
SYSVRF JOINT IN 01 3P 314157 257×127×107 0,8 &DSDFLW\RIFRQQHFWHGLQGRRUXQLWVN:
SYSVRF JOINT IN 02 3P 314158 287×137×107 0,9 Capacity of connected indoor units 16,6-33kW
SYSVRF JOINT IN 03 3P 314159 297×167×177 1,4 Capacity of connected indoor units 33-66kW
SYSVRF JOINT IN 04 3P 314160 372×197×187 2,3 Capacity of connected indoor units 66-92kW
SYSVRF JOINT IN 05 3P 314185 432×222×227 3,3 Capacity of connected indoor units > 92kW
Notes
www.systemair.com