FOOTING TYPES PLAN

[ Footing Bed Level ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10' Design specifications for foundation;


fc' = 2500 psi
4' 4' fy = 50000 psi (Main reinf.)
4'-9" 12'-6" 9'
12' 9'
12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fy = 50000 psi (Temp. & shri. reinf.)
5'
7' 6'
See " Structural Specifications and
K 7' F3 9' F5 9' F5 8' F8 6' F2 F2 F9 F7 F7 F3 Parameters" for more information.

12'-6" 7'
9' 9' 5'
7'
7' 11'

J 7' F3 9' F5 9' F5 8' F8 7' F3 F3 10' F9 11' F7 F7 F5 Government of Kachin State

13' 9' 9' 5'


7' 7'
Mohyin, Kachin State
I 7' F3 9' F5 9' F5 8' F8 7' F3 F3 F9 F7 F7 F5

12' 7'
5'
7'

H 7' F3 8' F8 7' F3 F3 F9 F5


COMPOUND OFFICE
19' 4-STOREYED R. C. BUILDING
12' 7' 18'

G 7' F3 9' F13 F13

12' 16' F15 F15


7'

120' F 7' F3 F3
10'
12' 7'
17'
7'

5'

E 5' F1 F3 7' 7' F10 F10 F3 Mohyin, Kachin State


10' 17' 18'
F11 20' F14 F14 F11
7'
5'

D 5' F1 F3 7' 7' F10 F10 F3


FOOTING TYPES PLAN
12' 8' 9'
11'

C 8' F4 9' F5 F5 F4

12' 17' F12 F12


8' 9' 3/64" = 1'

B 8' F4 9' F5 F5 F4 S.1


25.8.2015
12'-6" 7' 7' 7' 7'
10'

A 7' F3 7' F3 7' F3 7' F3 10' F6 F6 F3 F3 F3 F3

23'-3"

5' 6'

A' 5' F1 6' F2 F2 F1

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
FOOTING DETAILS ( F2 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 5 - K)

F2 ( 6' 0" x 6' 0" x 14" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
5
Parameters" for more information.
Type : C2a
Size : 14" x 14"
6'-0"
Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
6'-0"

K Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

BOTTOM STEEL ARRANGEMENT PLAN K-5


Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2'-0" )
2'-0"

B1b

1/4" = 1'
S.3
25.8.2015
C2a
7'-0"

14"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
6'-0"
hard broken brick, etc. and sand
SECTION X -X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F3 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 1-K )

F3 ( 7' 0" x 7' 0" x 14" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
1 See " Structural Specifications and
Parameters" for more information.
Type : C2a
7'-0" Size : 14" x 14"

Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
7'-0"

K Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

BOTTOM STEEL ARRANGEMENT PLAN 1-K


Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2' - 0" )
2' - 0"

B3b

1/4" = 1'
S.4
25.8.2015
C2a
7'-0"

14"
3"
Footing Bed Level ( - 7' - 0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
7'-0"
hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F4 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( I-11 )

F4 ( 8' 0" x 8' 0" x 14" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
1 fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
Type : C2a
8'-0"
Size : 14" x 14"

Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
8'-0"

C Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

BOTTOM STEEL ARRANGEMENT PLAN 1-C


Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2' - 0" )
2' - 0"

1/4" = 1'
S.5
25.8.2015
C2a
7'-0"

14"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
8'-0"
hard broken brick, etc. and sand
SECTION X -X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F5 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 2-K )

F5 ( 9' 0" x 9' 0" x 16" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
2
fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
9'-0"
Type : C2b
Size : 14" x 14"

Government of Kachin State

14"
14" Mohyin, Kachin State

X X
Main reinf. : 12 - 18d ,
Ties: 10d ( 1 hoop ) per set
9'-0"

K
See more details in columns schedule. COMPOUND OFFICE
4-STOREYED R. C. BUILDING

BOTTOM STEEL ARRANGEMENT PLAN 2-K


Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2'-0")
2'-0"

B3b B2

1/4" = 1'
S.6
25.8.2015
C2b
7'-0"

16"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
9'-0"
hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F6 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 5'-A )

F6 (10'-0"x 10'-0" x 18" )


Design specifications for foundation;
fc' = 2500 psi
5' fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
10'-0" Parameters" for more information.
Type : C2a
Size : 14" x 14"

Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
10'-0"

A Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

5'-A
BOTTOM STEEL ARRANGEMENT PLAN
Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2'-0" )
B1b
2'-0"

1/4" = 1'
S.7
25.8.2015
C2a
7'-0"

18"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
10'-0"
hard broken brick, etc. and sand
SECTION X -X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F2 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 8 - K)

F7( 11' 0" x 11' 0" x 22" )


Design specifications for foundation;
fc' = 2500 psi
8 fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)

11'-0"
See " Structural Specifications and
Parameters" for more information.
Type : C2a
Size : 14" x 14"

Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
11'-0"

K Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

8-K

Mohyin, Kachin State


BOTTOM STEEL ARRANGEMENT PLAN

Ground Floor Level ( + 2'-0")


FOOTING DETAILS
2'-0"
B2 B2

1/4" = 1'
C2b
S.8
25.8.2015
7'-0"

16"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
11'-0"
hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F2 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 4 - K)

F8( 5' 0" x 8' 0" x 18" )


Design specifications for foundation;
fc' = 2500 psi
4 fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
Type : C2a
Size : 14" x 14"
5'-0"
Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
8'-0"

K Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

4-K

Mohyin, Kachin State


BOTTOM STEEL ARRANGEMENT PLAN

Ground Floor Level ( + 2'-0")


FOOTING DETAILS

2'-0"
B2 B2

1/4" = 1'
C2b
S.9
25.8.2015
7'-0"

18"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
5'
hard broken brick, etc. and sand
SECTION X -X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F2 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 7 - K)

F9( 7' 0" x 10' 0" x 22" )


Design specifications for foundation;
fc' = 2500 psi
4 fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
Type : C2a
Size : 14" x 14"
7'-0"
Government of Kachin State

14"
14"
Mohyin, Kachin State

X X
Main reinf. : 8 - 18d ,
10'-0"

K Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

4-K

Mohyin, Kachin State


BOTTOM STEEL ARRANGEMENT PLAN

Ground Floor Level ( + 2'-0")


FOOTING DETAILS

2'-0"
B2 B2

1/4" = 1'
C2b
S.10
25.8.2015
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
7' chipping, broken concrete pieces,
hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F5 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 2,3-E )

F10 ( 7' 0" x 17' 0" x 22" )


Design specifications for foundation;
2 2
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)

17' See " Structural Specifications and


Parameters" for more information.
Type : C2b
Size : 14" x 14"

Government of Kachin State

14"
14" Mohyin, Kachin State
X X

E
7'

Main reinf. : 12 - 18d ,


Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

BOTTOM STEEL ARRANGEMENT PLAN

2-E 3-E
Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2'-0")
2'-0"

B1b B1b B1b

1/4" = 1'
S.11
25.8.2015
C2b C2b
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
17' hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F5 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 4-D,E )

2 F11 ( 7' 0" x 18' 0" x 22" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
7'
See " Structural Specifications and
Parameters" for more information.
Type : C2b
Size : 14" x 14"

Government of Kachin State

14"
E
14" Mohyin, Kachin State

Main reinf. : 12 - 18d ,


Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING
18'

4-D
X X

D
Mohyin, Kachin State

Ground Floor Level ( + 2'-0")


FOOTING DETAILS

2'-0"
B1b B1b

1/4" = 1'
BOTTOM STEEL ARRANGEMENT PLAN C2b
S.12
25.8.2015
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
7' chipping, broken concrete pieces,
hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F5 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 5-B,C )

5 F12 ( 11' 0" x 17' 0" x 22" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
11' fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
Type : C2b
Size : 14" x 14"

Government of Kachin State

14"
C
14" Mohyin, Kachin State

Main reinf. : 12 - 18d ,


Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING
17'

5-B
X X

B
Mohyin, Kachin State

Ground Floor Level ( + 2'-0")


FOOTING DETAILS

2'-0"
1/4" = 1'
C2b
BOTTOM STEEL ARRANGEMENT PLAN S.13
25.8.2015
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
11'
hard broken brick, etc. and sand
SECTION X -X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F5 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 2,3-G )

F13 ( 9' 0" x 19' 0" x 22" )


Design specifications for foundation;
2 2
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)

19' See " Structural Specifications and


Parameters" for more information.
Type : C2b
Size : 14" x 14"

Government of Kachin State

14"
14" Mohyin, Kachin State
X X

G
9'

Main reinf. : 12 - 18d ,


Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING

BOTTOM STEEL ARRANGEMENT PLAN

2-G 3-G
Mohyin, Kachin State

FOOTING DETAILS
Ground Floor Level ( + 2'-0")
2'-0"

B1b B1b B1b

1/4" = 1'
S.14
25.8.2015
C2b C2b
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
19' hard broken brick, etc. and sand
SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F5 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 5-D,E )

5 F14 ( 20' 0" x 10' 0" x 22" )


Design specifications for foundation;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
10' fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
Type : C2b
Size : 14" x 14"

Government of Kachin State

14"
E
14" Mohyin, Kachin State

Main reinf. : 12 - 18d ,


Ties: 10d ( 1 hoop ) per set

See more details in columns schedule. COMPOUND OFFICE


4-STOREYED R. C. BUILDING
20'

5-D
X X

D
Mohyin, Kachin State

Ground Floor Level ( + 2'-0")


B3a
FOOTING DETAILS

2'-0"
B1b

1/4" = 1'
C2b
BOTTOM STEEL ARRANGEMENT PLAN S.15
25.8.2015
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
10'
hard broken brick, etc. and sand
SECTION X -X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTING DETAILS ( F6 )

EXAMPLE OF FOOTING STEEL ARANGEMENT AT GRID ( 4,5-G,F )

F15 (18'-0"x 16'-0" x 22" )

Design specifications for foundation;


4 5 5'
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
18' fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
Parameters" for more information.
Type : C2a
G Size : 14" x 14"

Government of Kachin State

14"
14"
Mohyin, Kachin State

Main reinf. : 8 - 18d ,


Ties: 10d ( 1 hoop ) per set

COMPOUND OFFICE
16'

See more details in columns schedule.


4-STOREYED R. C. BUILDING

X X

F
4-F 5-F 5'-F
Mohyin, Kachin State

FOOTING DETAILS
BOTTOM STEEL ARRANGEMENT PLAN Ground Floor Level ( + 2'-0")
2'-0"

B1b

1/4" = 1'
S.16
25.8.2015
C2b C2b
7'-0"

22"
3"
Footing Bed Level ( - 7'-0" )
3" thick (1:4:8) lean concrete
Well-compacted soil using gravels,
chipping, broken concrete pieces,
18' hard broken brick, etc. and sand
SECTION X -X
Daw Nan Kay Zar Wint
U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


COLUMN TYPE PLAN
Between Footing Bed Level To Ground Floor Level ( + 2')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for columns;
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fy = 50000 psi (Main reinf.)
fy = 40000 psi (Ties)
K See " Structural Specifications and
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a Parameters" for more information.
12'-6"
J
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a Government of Kachin State
13'
I Mohyin, Kachin State
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a
12'
H
C2a C2a C2a C2a C2a C2a
COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

G
C2a C2b C2a C2a C2a C2a C2a C2a C2b C2a
12' C2c C2c
120' F
C2a C2a C2a C2a C2a C2a
12'
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a
E
C2a C2a
Mohyin, Kachin State
10'
D
C2a C2a C2a C2a C2a C2b C2b C2a C2a C2a C2a C2a
COLUMN
12'
TYPES PLAN
C
C2a C2a C2a C2a C2a C2a
12'
3/64" = 1'
B
C2c C2c C2a C2a C2c C2c S.17
25.8.2015
12'-6"
A
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a

23'-3"

A'
C1a C1a C1a C1a

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
COLUMN TYPE PLAN
Between Ground Floor (+2') To First Floor (+16')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for columns;
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fy = 50000 psi (Main reinf.)
fy = 40000 psi (Ties)
K See " Structural Specifications and
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a Parameters" for more information.
12'-6"
J
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a Government of Kachin State
13'
I Mohyin, Kachin State
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a
12'
H
C2a C2a C2a C2a C2a C2a
COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

G
C2a C2b C2a C2a C2a C2a C2a C2a C2b C2a
12' C2c C2c
120' F
C2a C2a C2a C2a C2a C2a
12'
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a
E
C2a C2a
Mohyin, Kachin State
10'
D
C2a C2a C2a C2a C2a C2b C2b C2a C2a C2a C2a C2a
COLUMN
12'
TYPES PLAN
C
C2a C2a C2a C2a C2a C2a
12'
3/64" = 1'
B
C2c C2c C2a C2a C2c C2c S.18
25.8.2015
12'-6"
A
C2a C2a C2a C2a C2a C2a C2a C2a C2a C2a

23'-3"

A'
C1a C1a C1a C1a

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
COLUMN TYPE PLAN
Between First Floor (+16') To Second Floor (+28')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for columns;
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' fy = 50000 psi (Main reinf.)
fy = 40000 psi (Ties)
K See " Structural Specifications and
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a Parameters" for more information.
12'-6"
J
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a Government of Kachin State
13'
I Mohyin, Kachin State
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
12'
H
C1a C1a C1a C1a C1a C1a
COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

G
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
12' C2a C2a
120' F
C1a C1a C1a C1a C1a C1a
12'
E
C1a C1a C1a C1a C1aC1a C1aC1a C1a C1a C1a C1a
Mohyin, Kachin State
10'
D
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
COLUMN
12'
TYPES PLAN
C
C1a C1a C1a C1a C1a C1a
12'
3/64" = 1'
B
C1a C1a C1a C1a C1a C1a S.19
25.8.2015
12'-6"
A
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
COLUMN TYPE PLAN
Between Second Floor (+28') To Third Floor(+39')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for columns;
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' fy = 50000 psi (Main reinf.)
fy = 40000 psi (Ties)
K See " Structural Specifications and
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a Parameters" for more information.
12'-6"
J
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a Government of Kachin State
13'
I Mohyin, Kachin State
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
12'
H
C1a C1a C1a C1a C1a C1a
COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

G
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
12' C2a C2a
120' F
C1a C1a C1a C1a C1a C1a
12'
E
C1a C1a C1a C1a C1aC1a C1aC1a C1a C1a C1a C1a
Mohyin, Kachin State
10'
D
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
COLUMN
12'
TYPES PLAN
C
C1a C1a C1a C1a C1a C1a
12'
3/64" = 1'
B
C1a C1a C1a C1a C1a C1a S.20
25.8.2015
12'-6"
A
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
COLUMN TYPE PLAN
Between Third Floor(+39') To Roof Level (+50')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for columns;
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' fy = 50000 psi (Main reinf.)
fy = 40000 psi (Ties)
K See " Structural Specifications and
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a Parameters" for more information.
12'-6"
J
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a Government of Kachin State
13'
I Mohyin, Kachin State
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
12'
H
C1a C1a C1a C1a C1a C1a
COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

G
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a
12' C1a C1a
120' F
C1a C1a C1a C1a C1a C1a
12'
E
C1a C1a C1a C1a C1aC1a C1aC1a C1a C1a C1a C1a
Mohyin, Kachin State
10'
D

COLUMN
12'
TYPES PLAN
C
C1a C1a C1a C1a C1a C1a
12'
3/64" = 1'
B
C1a C1a C1a C1a C1a C1a S.21
25.8.2015
12'-6"
A
C1a C1a C1a C1a C1a C1a C1a C1a C1a C1a

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
COLUMN TYPE PLAN
Between Roof Level (+50') To Roof Top Level

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for columns;
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' fy = 50000 psi (Main reinf.)
fy = 40000 psi (Ties)
K See " Structural Specifications and
C1a C1a C1a C1a Parameters" for more information.
12'-6"
C1a C1a C1a C1a
J
Government of Kachin State
13'
I Mohyin, Kachin State

12'
H

COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

12'
120' F

12'
E

Mohyin, Kachin State


10'
D

COLUMN
12'
TYPES PLAN
C

12'
3/64" = 1'
B
S.22
25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
GENERAL COLUMN STEEL ARRANGEMENT EXAMPLE OF COLUMN STEEL ARRANGEMENT AT GRID K-10
3-K 5'-D

Roof Floor Level ( + 39'-6" )

8d@6"c/c
clear height /6

Design specifications for columns;


Largest of
C1 or C2

l0
l0 = 21" Type : C1a
fc' = 2500 psi
C2
18"

Size : 12" x 12" fy = 50000 psi (Main reinf.)

8d@12"c/c
fy = 40000 psi (Ties)

Splice length (34d b)

12"
Clear height

See " Structural Specifications and

Splice length (34d b)


12"
Parameters" for more information.

8d@6"c/c
C1/C2

10'-4"
Main reinf. : 8 - 16d ,
C1/C2 Ties: 8d ( 1 hoop ) per set

8d@12"c/c
clear height /6

See more details in columns schedule.


Government of Kachin State
Largest of

special ties at bend


C1 or C2

l0
( 2 sets @3" c/c )
18"

l0 = 21"
2nd Floor Level ( + 27'-6" ) Mohyin, Kachin State

8d@6"c/c
clear height /6
Largest of
C1 or C2

l0
Type : C1a
18"

l0 = 21"
C1/C2 C1a Size : 12" x 12"

COMPOUND OFFICE
Splice length (34d b)

8d@12"c/c
C1/C2
4-STOREYED R. C. BUILDING
Clear height

12"
Splice length (34d b)
12"

8d@6"c/c
10'-4"
Main reinf. : 8 - 16d ,
Ties: 8d ( 1 hoop ) per set

8d@12"c/c
clear height /6

See more details in columns schedule.


Largest of
C1 or C2

l0
special ties at bend
18"

( 2 sets @3" c/c )

8d@6"c/c
special ties at bend
l0 = 21"
( 2 sets @3" c/c )
1st Floor Level ( + 15'-6" )
clear height /6

Mohyin, Kachin State


Largest of
C1 or C2

l0
C1/C2
10d@6"c/c
18"

l0 = 25"
C1/C2 Type : C2a
Splice length (34d b)

Size : 14" x 14"


COLUMN STEEL
ARRANGEMENT
10d@12"c/c
Clear height

C2a

14"
Splice length (34d )
b
14"
10d@6"c/c
12'-4"

Main reinf. : 8 - 18d , 3/64" = 1'


Ties: 10d ( 1 hoop ) per set
S.23
10d@12"c/c

See more details in columns schedule.


clear height /6

special ties at bend


25.8.2015
Largest of

special ties at bend


C1 or C2

l0
( 2 sets @3" c/c ) ( 2 sets @3" c/c )
18"

slope 1:6 l0 = 25"


clear height /6

Ground Floor Level ( + 1'-6" )


Largest of
C1 or C2

l0
18"

10d@6"c/c

Type : C2a
Size : 14" x 14"
C1/C2 C2a
Clear height

14"
C1/C2
7'-4"

14"

Main reinf. : 8 - 18d ,


clear height /6

Ties: 10d ( 1 hoop ) per set


Largest of
C1 or C2

l0
See more details in columns schedule.
3"
18"

Footing Bed Level ( - 7'-0" ) Daw Nan Kay Zar Wint


3" thick (1:4:8) lean concrete
Foundation U Lin Htet Han
Well-compacted soil using gravels,
chipping, broken concrete pieces,
9'-0"
hard broken brick, etc. and sand P PIONEER Structural Design Group
(3) C1 and C2 are dimensions of two sides of the column section. (5) Cut off or add column main reinforcement at floor level,
(2) l0 is the largest of: larger column dimension, clear height / 6 and 18". (4) Do not splice more than 50% of the total column longitudinal steel anywhere. and not at mid-height splices. Ph. 01-652831 ; 651165-2425
BEAM TYPE PLAN
At Ground Floor Level(+2')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'

4' 4' Design specifications for beams;


4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fc' = 2500 psi
fy = 50000 psi (Main reinf.)
K
B3b B2 B2 B1b B1b B2 B2 B3b fy = 40000 psi (Stirrups)
See " Structural Specifications and

B1b

B1b

B1b

B1b

B1b

B1b
12'-6" Parameters" for more information.
B1b B2 B2 B1b B1b B2 B2 B1b
J

Government of Kachin State

B1b

B1b

B1b

B1b

B1b

B1b
13'
B1b B1b B1b B1b B1b B1b B1b B1b
I
B1b Mohyin, Kachin State

B1b

B1b

B1b

B1b

B1b
12'
H
B1b

B1b

B1b

B1b

B1b

B1b
12' COMPOUND OFFICE
B1b B1b B1b B1b B1b B1b B1b B1b 4-STOREYED R. C. BUILDING
G
B2
B1b

B1b

B1b

B1b
12'
120' F

B2
B2

B2
B1b

B1b

B1b

B1b

B1b

B1b
12'
B1b B1b B1b B1b B1b B3a B1b B1b B1b B1b B1b
B1b B1b
E
B1b

B1b

B1b
B1b

B1b
B1b

B1b

B1b
10' Mohyin, Kachin State
B1b B1b B1b B1b B3a B1b B1b B1b B1b
D
B1b B1b
B1b

B1b

B1b

B1b

B1b

B1b
12' BEAM TYPES
C PLAN
B1b

B1b

B1b

B1b

B1b

B1b
12'
B 3/64" = 1'
S.24
B1b

B1b

B1b

B1b

B1b

B1b
12'-6" 25.8.2015
B1b B1b B1b B1b B1b B1b B1b B1b
A
B3b
B3b

B3b

B3b

23'-3"

A'
B1a B1a B1a

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
BEAM TYPES PLAN
At First Floor Level (+16')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'

Design specifications for beams;


4' 4'
fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9"
fy = 50000 psi (Main reinf.)
B3a B2 B2 B1b B1b B2 B2 B3a fy = 40000 psi (Stirrups)
K
See " Structural Specifications and

B1b

B1b
B1b

B1b

B1b

B1b

B1b
B1b

B2

B2
Parameters" for more information.

B1b
12'-6"

B1b
B1b B2 B2 B1b B1b B2 B2 B1b
J

Government of Kachin State

B1b
B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b
13'
B1b B1b B1b B1b B1b B1b B1b B1b
I
Mohyin, Kachin State

B1b
B1b

B1b

B1b

B1b

B1b
B3b

B3b
B3b

B3b
12'
B1b B1b B1b B1b B1b B1b B1b B1b
H

B3b

B3b
B1b
COMPOUND OFFICE
B1b

B1b

B1b

B1b

B1b
B3b

B3b
12'
B1b B1b B1b B1b B1b B1b B1b B1b 4-STOREYED R. C. BUILDING
G
B2
B3b

B1b

B3b
B1b

B3b

B1b

B1b

B1b

B3b

B1b
12'
120' F
B1b B1b B1b B1b B1b B1b B1b B1b

B2
B2
B3b

B3b
B3b

B3b
B1b
B1b

B1b

B1b

B1b

B1b
12'
B1b B1b B1b B1b B1b B3a B1b B1b B1b B1b B1b
B1b B1b
E
B1b

B1b

B1b

B1b
B1b

B1b
B1b
B1b

B1b

B1b
B1b

B1b

B1b
B1b
10' Mohyin, Kachin State
B1b B1b B1b B1b B3b B1b B1b B1b B1b
D
B1b B1b
B1b

B1b
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b
12' BEAM TYPES
B3b B3b B1b B1b B3b B1b B1b B3b B3b PLAN
C
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b
12'
B3b B3b B1b B1b B3b B1b B1b B3b B3b 3/64" = 1'
B

S.25
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b
B1b

B1b
12'-6" 25.8.2015
B1b B1b B1b B1b B3b B1b B1b B1b B1b
A
B3b
B3a

B3b

B3a

23'-3"

A'
B3a B3a B3a

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
BEAM TYPES PLAN
[ At Second Floor Level (+28') ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for beams;
4' fc' = 2500 psi
4'
fy = 50000 psi (Main reinf.)
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9"
fy = 40000 psi (Stirrups)
B3a B2 B2 B1b B1b B2 B2 B3a
K See " Structural Specifications and
Parameters" for more information.

B1b

B1b
B1b
B1b

B1b

B1b

B1b

B1b

B1b
B2

B2

B1b
12'-6"
B1b B2 B2 B1b B1b B2 B2 B1b
J
Government of Kachin State

B1b
B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b
13'
I
B1b B1b B1b B1b B1b B1b B1b B1b Mohyin, Kachin State

B1b
B1b

B1b

B1b

B1b

B1b
B3b

B3b
B3b

B3b
12'
B1b B1b B1b B1b B1b B1b B1b B1b
H
COMPOUND OFFICE
B3b

B3b
B1b
4-STOREYED R. C. BUILDING
B1b

B1b

B1b

B1b

B1b
B3b

B3b
12'
B1b B1b B1b B1b B1b B1b B1b B1b
G
B2
B3b

B3b
B1b
B3b

B3b
B1b

B1b

B1b

B1b

B1b
12'
120' F
B1b B1b B1b B1b B1b B1b B1b B1b

B2
B2
B3b

B3b
B3b

B3b
B1b
B1b

B1b

B1b

B1b
12'
B1b B1b B1b B1b B1b B3a B1b B1b B1b B1b B1b
E
Mohyin, Kachin State
B1b

B1b

B1b

B1b
B1b

B1b
B1b
B1b

B1b
B1b

B1b
10'
B1b B1b B1b B1b B3b B1b B1b B1b B1b
D
BEAM TYPES
B1b

B1b
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b
12' PLAN
B3b B3b B1b B1b B3b B1b B1b B3b B3b
C
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b
12'
3/64" = 1'
B3b B3b B1b B1b B3b B1b B1b B3b B3b
B S.26
25.8.2015
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b
B1b

12'-6" B1b

B1b B1b B1b B1b B3b B1b B1b B1b B1b


A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
BEAM TYPES PLAN
[ At Third Floor Level (+39') ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for beams;
4' fc' = 2500 psi
4'
fy = 50000 psi (Main reinf.)
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9"
fy = 40000 psi (Stirrups)
B3a B2 B2 B1b B1b B2 B2 B3a
K See " Structural Specifications and
Parameters" for more information.

B1b
B1b

B1b

B1b

B1b

B1b
B1b

B1b

B1b

B1b
B2

B2
12'-6"
B1b B2 B2 B1b B1b B2 B2 B1b
J
Government of Kachin State

B1b
B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b
13'
I
B1b B1b B1b B1b B1b B1b B1b B1b Mohyin, Kachin State

B1b
B1b

B1b

B1b

B1b

B1b
B3b

B3b
B3b

B3b
12'
B1b B1b B1b B1b B1b B1b B1b B1b
H
B3b COMPOUND OFFICE

B3b
B1b
4-STOREYED R. C. BUILDING
B1b

B1b

B1b

B1b

B1b
B3b

B3b
12'
B1b B1b B1b B1b B1b B1b B1b B1b
G
B2
B3b

B3b
B1b
B3b

B3b
B1b

B1b

B1b

B1b

B1b
12'
120' F
B1b B1b B1b B1b B1b B1b B1b B1b

B2
B2
B3b

B3b
B3b

B3b
B1b
B1b

B1b

B1b

B1b
12'
B1b B1b B1b B1b B1b B3a B1b B1b B1b B1b B1b
E
Mohyin, Kachin State
B1b

B1b

B1b

B1b
B1b

B1b
B1b
B1b

B1b
B1b

B1b
10'
B1b B1b B1b B1b B3b B1b B1b B1b B1b
D
BEAM TYPES
B1b

B1b
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b
12' PLAN
B3b B3b B1b B1b B3b B1b B1b B3b B3b
C
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b

B1b

B1b
12'
3/64" = 1'
B3b
B
B3b B3b B1b B1b B1b B1b B3b B3b
S.27
25.8.2015
B1b

B1b
B1b

B1b

B1b

B1b

B1b

B1b
B1b

B1b
12'-6"
B1b B1b B1b B1b B3b B1b B1b B1b B1b
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han

Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group

For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
BEAM TYPES PLAN
[ At Roof Level (+50') ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'

4' 4' Design specifications for beams;


4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fc' = 2500 psi
fy = 50000 psi (Main reinf.)
B2 B2 B2 B1a B1a B2 B2 B2
K fy = 40000 psi (Stirrups)
See " Structural Specifications and

B1a

B1a
B2

B2
B1a

B1a
B1a

B1a
B2

B2
12'-6" Parameters" for more information.
B3b B3b B2 B1a B1a B2 B3b B3b B1a
J

B1a

B1a

B1a
B1a
B1a B1a

B1a

B1a
B1a
B1a

B1a
B1a
B1a

B1a
13' Government of Kachin State

B2

B2
B1a B2 B2 B1a B1a B1a B1a B2 B2 B1a
I

Mohyin, Kachin State

B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
12'
B1a B1a B1a B1a
H

B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
12'
COMPOUND OFFICE
B1a B1a B1a B1a
G
B1a B1a B1a B1a B1a B1a 4-STOREYED R. C. BUILDING
B1a

B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
12'

B1a

B1a
B1a

B1a
120' F
B1a B1a B1a B1a B1a

B1a

B1a
B1a
B1a

B1a

B1a

B1a
B1a
B1a

B1a
B1a

B1a
B1a

B1a
12'
B1a B1a B1a B1a B1b B1a B1b B1a B1a B1a B1a
B1a B1a
E

B1a

B1a

B1a

B1a

B1a

B1a
B1a

B1a
B1a

B1a
B1a

B1a
B1a B1a B1a B1a B1a B1a
B1a

B1a
10'
B1a

B1a

B1a

B1a

B1a

B1a
B1a B1a B1a B1a B1a B1a B1a B1a B1a Mohyin, Kachin State
D
B1a B1a
B1a

B1a
B1a

B1a

B1a

B1a
B1a

B1a
12'
BEAM TYPES
B1a B1a
C
PLAN
B1a

B1a
B1a

B1a

B1a

B1a
B1a

B1a
12'
B1a B1a
B
3/64" = 1'
B1a

B1a
B1a

B1a

B1a

B1a
S.28
B1a

B1a
12'-6" B1a B1a B1a B1a B1a
25.8.2015

B1a
B1a

B1a

B1a
B1a

A
B1a B1a B1a B1a B1a B1a B1a B1a B1a

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
BEAM TYPES PLAN
[ At Roof Top Level ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for beams;
C1a
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
C1a B1a C1a C1a B1a C1a
K
See " Structural Specifications and

B1a

B1a

B1a

B1a
Parameters" for more information.
12'-6" C1a B1a C1a C1a B1a C1a

J
Government of Kachin State
13'
I Mohyin, Kachin State

12'
H

COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING
G

12'
120' F

12'
E

Mohyin, Kachin State


10'
D

BEAM TYPES
12'
PLAN
C

12'
3/64" = 1'
B
S.29
25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
BEAM TYPES PLAN
[ Landing Beam and Slab ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for beams;
C1a
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
B3a B3a
K
See " Structural Specifications and
S2 Parameters" for more information.

B3a

B3a
B3a

B3a
5'
12'-6" S2

J
B3a B3a
Government of Kachin State
13'
I Mohyin, Kachin State

12'
H

COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING
G
B3a
12'

B3a
B3a
S2 7'-6"
120' F
B3a

12'
E

Mohyin, Kachin State


10'
D

BEAM TYPES
12'
PLAN
C

12'
3/64" = 1'
B
S.30
25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
R. C. BEAMS DETAILS

EXAMPLE - 4 FOR TYPE B3b


LOCATION - Grid line 11 [ Second Floor Level (+27'-6") ]
Design specifications for beams;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
See " Structural Specifications and
3-20d 3-20d 3-20d 3-20d 3-20d Parameters" for more information.
2-20d 2-20d 2-20d 2-20d

Government of Kachin State

Mohyin, Kachin State


B3b F B3b G B3b H B3b

12'-0" 12'-0"

7'-8" 7'-8" COMPOUND OFFICE


4-STOREYED R. C. BUILDING

3-20d
1" Clear

X1 X2 2-20d
2-12d

4-8d hanger
1" Clear

X1 X2 stirrups 2-20d
(See Note) 3-20d
Mohyin, Kachin State
40" 40"
10d @ 4"
10d @ 3" 10d @ 3"

R. C. FLOOR BEAM DETAILS


2-12d 2-12d 2-12d 2-12d 2-12d

3-20d 3-20d 3-20d 3-20d 3-20d


3-20d 3-20d 3-20d 3-20d 3-20d

3/64" = 1'
S.31
25.8.2015

3-20d 3-20d
2-20d

4" 4"

20" 20"
2-12d 2-12d

2-20d 2-20d
3-20d 3-20d
10" 10"

Section X1-X1 Section X2-X2

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group


Note : 1. As an example, 22d means 22mm diameter bar.
2. Where secondary beam crosses the main beam, provide 4 hanger stirrups, 2 inside the main reinforcement of secondary beam and the rest about 2" outside of secondary beam surface, one on each side. Ph. 01-652831 ; 651165-2425
R. C. BEAMS DETAILS

EXAMPLE - 3 FOR TYPE B3a


LOCATION - Grid line 2 [ Second Floor Level (+27'-6") ]
Design specifications for beams;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
4-18d 3-18d See " Structural Specifications and
Parameters" for more information.
3-20d 3-20d 3-20d 3-20d

Government of Kachin State

Mohyin, Kachin State

B1b 4 B3a 5' B3a 6' B1a

12'-0" 24'-0" COMPOUND OFFICE


4-STOREYED R. C. BUILDING

X1 3-20d 3-20d
2-12d 2-12d

Mohyin, Kachin State


X1 3-20d 3-20d

40" 40" 40" 40" R. C. FLOOR BEAM DETAILS


10d @ 4" 10d @ 4"
10d @ 3" 10d @ 3" 10d @ 3" 10d @ 3"

2-12d 2-12d 2-12d 2-12d

3/64" = 1'
3-20d 3-20d 3-20d 3-20d
4-18d 3-18d S.32
25.8.2015

3-20d

4"

20"
2-12d

3-20d
10"

Section X1-X1
Daw Nan Kay Zar Wint
U Lin Htet Han

P PIONEER Structural Design Group


Note : 1. As an example, 22d means 22mm diameter bar.
2. Where secondary beam crosses the main beam, provide 4 hanger stirrups, 2 inside the main reinforcement of secondary beam and the rest about 2" outside of secondary beam surface, one on each side. Ph. 01-652831 ; 651165-2425
R. C. BEAMS DETAILS

EXAMPLE - 2 FOR TYPES B1b & B2


LOCATION - Grid line 4 [ Ground Floor Level (+1'-6") ]
Design specifications for beams;
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
4-18d 4-18d 4-18d 4-18d
See " Structural Specifications and
Parameters" for more information.

1 2 3 Government of Kachin State

B1b B1b B2
Mohyin, Kachin State
12'-6" 12'-0"

X1 4-18d X2 4-18d COMPOUND OFFICE


4-STOREYED R. C. BUILDING

X1 4-18d X2 4-18d

28" 28" 32" 32"


8d @ 4" 10d @ 5"
8d @ 3" 8d @ 3" 10d @ 3" 10d @ 3"

Mohyin, Kachin State

4-18d 4-18d
4-18d 4-18d
R. C. FLOOR BEAM DETAILS

3/64" = 1'
S.33
4-18d 4-18d 25.8.2015

14" 16"

4-18d
4-18d
10"
10"

Section X1-X1 Section X2-X2

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group


Note : 1. As an example, 22d means 22mm diameter bar.
2. Where secondary beam crosses the main beam, provide 4 hanger stirrups, 2 inside the main reinforcement of secondary beam and the rest about 2" outside of secondary beam surface, one on each side. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
At First Floor Level (+16')

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for slab;
4' 4' f ' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" f = 50000 psi (Main reinf.)
f = 50000 psi (Temp. shri. reinf.)
K See " Structural Specifications and
S1 S1
S1 S1
S1 S1 Parameters" for more information.
12'-6"
J
Government of Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
13'
I Mohyin, Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
12'
H

S1 S1 S1 S1 S1 S1 S1 S1 COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

S1 S1 S1 S1 S1 S1 S1 S1
12'
7'-6"
120' F

S1 S1 S1 S1 S1 S1 S1 S1
12'
E
S1 S1 S1 S1 S2
S2 S2
S1 S1 S1 S1 Mohyin, Kachin State
10'
D

S1 S1 S1 S1 S2 S1 S1 S1 S1 SLAB TYPES
12'
PLAN
C

S1 S1 S1 S1 S2 S1 S1 S1 S1
12'
3/64" = 1'
B
S.34
S1 S1 S1 S1 S2 S1 S1 S1 S1 25.8.2015
12'-6"
A

S1 S1 S1
23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Second Floor Level (+28') ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for slab;
4' 4' f ' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" f = 50000 psi (Main reinf.)
f = 50000 psi (Temp. shri. reinf.)
K See " Structural Specifications and
S1 S1
S1 S1
S1 S1 Parameters" for more information.
12'-6"
J
Government of Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
13'
I Mohyin, Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
12'
H

S1 S1 S1 S1 S1 S1 S1 S1 COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

S1 S1 S1 S1 S1 S1 S1 S1
12'
7'-6"
120' F

S1 S1 S1 S1 S1 S1 S1 S1
12'
E

S1 S1 S1 S1 S2
S2 S2
S1 S1 S1 S1 Mohyin, Kachin State
10'
D

S1 S1 S1 S1 S2 S1 S1 S1 S1 SLAB TYPES
12'
PLAN
C

S1 S1 S1 S1 S2 S1 S1 S1 S1
12'
3/64" = 1'
B
S.35
S1 S1 S1 S1 S2 S1 S1 S1 S1 25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Second Floor Level (+28') ]

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for slab;
f ' = 2500 psi
f = 50000 psi (Main reinf.)
f = 50000 psi (Temp. shri. reinf.)
K See " Structural Specifications and
S1 S1
S1 S1
S2 S1 S1
Parameters" for more information.
12'-6"
J
Government of Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
13'
I Mohyin, Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
12'
H

S1 S1 S1 S1 S1 S1 S1 S1 COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

S1 S1 S1 S1 S1 S1 S1 S1
12'
7'-6"
120' F

S1 S1 S1 S1 S1 S1 S1 S1
12'
E

S1 S1 S1 S1 S2
S2 S2
S1 S1 S1 S1 Mohyin, Kachin State
10'
D

S1 S1 S1 S1 S2 S1 S1 S1 S1 SLAB TYPES
12'
PLAN
C

S1 S1 S1 S1 S2 S1 S1 S1 S1
12'
3/64" = 1'
B
S.36
S1 S1 S1 S1 S2 S1 S1 S1 S1 25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Third Floor Level (+39') ]

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for slab;
f ' = 2500 psi
f = 50000 psi (Main reinf.)
f = 50000 psi (Temp. shri. reinf.)
K See " Structural Specifications and
S1 S1
S1 S1
S1 S1
Parameters" for more information.
12'-6"
J
Government of Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
13'
I Mohyin, Kachin State
S1 S1 S1 S1 S1 S1 S1 S1
12'
H

S1 S1 S1 S1 S1 S1 S1 S1 COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING

S1 S1 S1 S1 S1 S1 S1 S1
12'
7'-6"
120' F

S1 S1 S1 S1 S1 S1 S1 S1
12'
E

S1 S1 S1 S1 S2 S1 S1 S1 S1 Mohyin, Kachin State


10'
S2 S2

S1 S1 S1 S1 S2 S1 S1 S1 S1 SLAB TYPES
12'
PLAN
C

S1 S1 S1 S1 S2 S1 S1 S1 S1
12'
3/64" = 1'
B
S.37
S1 S1 S1 S1 S2 S1 S1 S1 S1 25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Roof Level (+50') ]

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'

4' 4' Design specifications for beams;


4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fc' = 2500 psi
6"
fy = 50000 psi (Main reinf.)
K
6"
fy = 40000 psi (Stirrups)
S3 S2 S3 S3 S2 See " Structural Specifications and
12'-6" 5'
S3 S2

Parameters" for more information.


J
S3
S3

S2 S2 S2

13' S2
Government of Kachin State

S2 S2
Mohyin, Kachin State
12' S2
S2

12' S2 S2 S2
S2

COMPOUND OFFICE
G 4-STOREYED R. C. BUILDING

12' S2 S2
S2 S2 S2 S2
S2
S2

120' F
S2
S2 S2

12'
S2 S2 S2

E
S2
S2 S2 S2 S2 S2

10' S2

S2 S2 S2 S2
S2

Mohyin, Kachin State


S2 S2

S2 S2

12'
SLAB TYPES
C
S2
PLAN
12' S2

B
3/64" = 1'

12'-6" S2
S2
S.38
S2 S2
S2
S2 S2 S2 S2 S2 S2 S2
25.8.2015
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Roof Top Level (+50') ]

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'


Design specifications for beams;
C1a
4' 4' fc' = 2500 psi
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
C1a B1a C1a C1a B1a C1a
K
S2 S2
See " Structural Specifications and

B1a

B1a

B1a

B1a
Parameters" for more information.
12'-6" C1a B1a C1a C1a B1a C1a

J
Government of Kachin State
13'
I Mohyin, Kachin State

12'
H

COMPOUND OFFICE
12' 4-STOREYED R. C. BUILDING
G

12'
120' F

12'
E

Mohyin, Kachin State


10'
D

SLAB TYPES
12'
PLAN
C

12'
3/64" = 1'
B
S.39
25.8.2015
12'-6"
A

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
EXAMPLE OF STAIR DETAILS

ST-1( First Floor Level To Second Floor Level )

K L M
Design specifications for slab;
f ' = 2500 psi
12'-0" 12'-0" f = 50000 psi (Main reinf.)
f = 50000 psi (Temp. shri. reinf.)
See " Structural Specifications and
10d@ 6" c/c 1 Parameters" for more information.
B1a B1a 0d
@
6"
7 10d@ 6" c/c c/c

Government of Kachin State


10d@ 6" c/c 10 10
d@ d@
6'-0"

6" 6"
c/c c /c 10 Mohyin, Kachin State
d@
6"
c/c
8 10d@ 6" c/c
10 10d@ 6" c/c
d@
6" COMPOUND OFFICE
B3a

B3a
c/c 4-STOREYED R. C. BUILDING
10d@ 6" c/c
12'-0"

1 1 1

6'-0" 12'-0"

9' Mohyin, Kachin State


1'-6"

9
B3a B3a
+15'-6" FIRST FLOOR LEVEL
UP STAIR DETAILS

STAIR PLAN

7'-0"
3/16" = 1'
K L M 4'-
10d@ 6" c/c
6" S.40
25.8.2015

12'-0" 12'-0" 10d@ 6" c/c

10d@6" c/c

10d@6" c/c 4'-


6"

7'-0"
B3a B3a 13 10d@ 6" c/c

61
2"
'-2 13
16 "
7
11"

+1'-6" GROUND FLOOR LEVEL


B3a

B3a

B3a
6'-0"

B3a B3a 18'-0"


8 SECTION ( Y-Y ) Daw Nan Kay Zar Wint
U Lin Htet Han
LANDING PLAN
P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


EXAMPLE OF STEEL ARRANGEMENT IN SLAB
( At Roof Floor Slab Level )
( For S3 )

Design specifications for slab;


f ' = 2500 psi
f = 50000 psi (Main reinf.)
E F G H E F G H f = 50000 psi (Temp. shri. reinf.)
See " Structural Specifications and
Parameters" for more information.

1 1
Government of Kachin State

X X
S2 S1 S2 S1 Mohyin, Kachin State
X X

2 2 COMPOUND OFFICE
4-STOREYED R. C. BUILDING

S2 S1 S2 S1

3 3
Mohyin, Kachin State

EXAMPLE OF STEEL
BOTTOM STEEL ARRANGEMENT PLAN TOP STEEL ARRANGEMENT PLAN
ARRANGEMENT IN SLAB

E F G H 3/64" = 1'
S.41
25.8.2015
2'-0" 2'-0" 2'-0"

4'-3" 4'-3"

10d @ 8" bothways


4"

5"
10d @ 8" bothways

SECTION X-X

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


EXAMPLE OF STEEL ARRANGEMENT IN SLAB
( At 2nd Floor Slab Level )
( For S1 and S2 )

K L M K L M Design specifications for slab;


f ' = 2500 psi
f = 50000 psi (Main reinf.)
f = 50000 psi (Temp. shri. reinf.)

Y
See " Structural Specifications and
Parameters" for more information.

11 11 Government of Kachin State

Mohyin, Kachin State


S1 S1 S1 S1

10d @ 8" bothways


10d @ 8" bothways COMPOUND OFFICE
4-STOREYED R. C. BUILDING
12 12

S1 S1
S1 S1

13 13 Mohyin, Kachin State

S2 S2 S2 S2
EXAMPLE OF STEEL
ARRANGEMENT IN SLAB
Y

3/64" = 1'
BOTTOM STEEL ARRANGEMENT PLAN TOP STEEL ARRANGEMENT PLAN

25.8.2015

13
11 12

12'-0" 12'-0" 5'-0"

4'-2" 4'-2" 4'-2" 4'-2"

10d @ 8" bothways 10d @ 8" bothways


4"

4"
10d @ 8" bothways 10d @ 8" bothways
Daw Nan Kay Zar Wint
U Lin Htet Han
SECTION X-X
P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


RETAINING WALL LOCATION PLAN

121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'

4' 4'
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" Design specifications for retaining wall;
fc' = 2500 psi
K
R. W. 2 R. W. 2 R. W. 2 R. W. 2 R. W. 2 R. W. 2 R. W. 2 R. W. 2 fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)

R. W. 2

R. W. 2
R. W. 2

R. W. 2
12'-6" See " Structural Specifications and
Parameters" for more information.
J

R. W. 2

R. W. 2
R. W. 2

R. W. 2
13'
Government of Kachin State
I

R. W. 2

R. W. 2

R. W. 2

R. W. 2
12' Mohyin, Kachin State

R. W. 2

R. W. 2
R. W. 2

R. W. 2
12'
COMPOUND OFFICE
G
4-STOREYED R. C. BUILDING
R. W. 2
R. W. 2

R. W. 2
R. W. 2

R. W. 2
12'

R. W. 2

R. W. 2
120' F
R. W. 2

R. W. 2
R. W. 2

R. W. 2
12'
R. W. 2 R. W. 2
E
R. W. 2 R. W. 2
R. W. 2

R. W. 2

R. W. 2

R. W. 2
10'
D Mohyin, Kachin State
R. W. 2 R. W. 2
R. W. 2

R. W. 2
12'
REATINING WALL
C

LOCATION PLAN
R. W. 2

R. W. 2
12'
B

3/64" = 1'
R. W. 2

R. W. 2
12'-6" S.43
25.8.2015
A
R. W. 2 R. W. 2 R. W. 2 R. W. 2 R. W. 2 R. W. 2
R. W. 1
R. W. 1

23'-3"

A'
R. W. 1 R. W. 1 R. W. 1

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Roof Level (+50') ]

121'
Design specifications for beams;
1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'
fc' = 2500 psi
fy = 50000 psi (Main reinf.)
4' 4' fy = 40000 psi (Stirrups)
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9"
See " Structural Specifications and
K
6"
Parameters" for more information.
6"

S3 S2 S3 S3 S2

12'-6" 5'
S3 S2

Government of Kachin State


J
S3
S3

S2 S2 S2

13' S2

Mohyin, Kachin State

S2 S2

12' S2
S2

H
COMPOUND OFFICE
4-STOREYED R. C. BUILDING

12' S2 S2 S2
S2

12' S2 S2
S2 S2 S2
S2
S2

120' F
S2
S2 S2

12'
S2 S2 S2

Mohyin, Kachin State


E
S2
S2 S2 S2 S2 S2

10' S2

S2 S2 S2
S2 S2 S2
S2

D
ROOF PLAN
S2 S2

12'
C
S2

3/64" = 1'
12' S2

S.46
B 25.8.2015

S2

12'-6" S2

S2
S2 S2 S2 S2 S2 S2 S2 S2 S2

23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
SLAB TYPES PLAN
[ At Roof Level (+50') ]
121'

1' 1 2 3 4 5 5' 6' 6 7 8 9 10 10'

4' 4'
4'-9" 12'-6" 12' 12' 8' 24' 8' 12' 12' 12'-6" 4'-9" Design specifications for beams;
fc' = 2500 psi
K
fy = 50000 psi (Main reinf.)
fy = 40000 psi (Stirrups)
12'-6" See " Structural Specifications and

Truss - 9

Truss - 7

Truss - 8

Truss - 8

Truss - 7

Truss - 9
Tr Tr
us u

-3

-3
s ss Parameters" for more information.

s
J -3 -3

us

us
Tr

Tr
13'
Government of Kachin State
Truss - 1
I

12' Truss - 1 Mohyin, Kachin State

H
Truss - 1
12'
Truss - 1 COMPOUND OFFICE
G
4-STOREYED R. C. BUILDING

12' Truss - 1
-3
ss

Tr

Truss - 7
120'

us
u
F
Tr

s
Truss - 1 Truss - 1

-3
Truss - 1 Truss - 1
12'
Truss - 1 Truss - 1

E Truss - 1 Truss - 1

Truss - 1 Truss - 1
10'
D
Truss - 1 Truss - 1
Truss - 1 Mohyin, Kachin State

Tr

-3
us

s
s

us
12'
-3
Tr
Truss - 5 ROOF TRUST
C
Truss - 1 Truss - 1 PLAN
Truss
12' - 4 Truss - 4

B
Truss - 6 Truss - 6
3/64" = 1'
12'-6" S.47
25.8.2015
-2

Tr
A
s

us
us

s
Tr

-2
Truss - 1

Truss - 1

Truss - 1

Truss - 1

Truss - 1

Truss - 1

Truss - 1

Truss - 1

Truss - 1

Truss - 1
23'-3"

A'

Daw Nan Kay Zar Wint


U Lin Htet Han
Note : those shown as are cut off at levels indicated, otherwise at the upper end of the column segment.
P PIONEER Structural Design Group
For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings. Ph. 01-652831 ; 651165-2425
TRUSS SECTION

2 3 4

12'-0" 12'-0" Government of Kachin State

Detail - B
Mohyin, Kachin State

( +57'10" )
TU1
TU1
Detail - D

TU 1
TU1 COMPOUND OFFICE
19'1
0" 4-STOREYED R. C. BUILDING

1 "TU1
TU1
TU1

6'-716
TU2

TU2
TU

2
TU
TU1
TU 1
2
TU2

TU2
TU

2
TU
2

TU 2
TU2

TU2
2 TU TU1
TU1 TU2 2 "3
TU
2'-11 4
TU2

TU2
36'-0" ( +50'- 6" )
TU1 TU1 TU1 TU1 TU1 TU1 TU1 TU1 TU1 TU1 ( +50'- 0" ) ROOF FLOOR LEVEL
Mohyin, Kachin State

Detail - A
Detail - C
TRUSS SECTION

Truss 1 1/4" = 1'


S.48
25.8.2015

For Detail A, B, C & D


see Page. no. 50

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION Design specifications for steel truss;
(Ref. from Pg. no 38) A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

Government of Kachin State

Mohyin, Kachin State

( +57'10" )
TU1

COMPOUND OFFICE
TU1 4-STOREYED R. C. BUILDING
3"
27'-
TU1

TU1
6'-741"
TU
2
TU2
TU 1

TU
TU

2
2 TU2
TU2

TU1 TU2
TU2

( +50'- 6" )
TU1 TU1 TU1 26'5" TU1 TU1 ( +50'- 0" ) ROOF FLOOR LEVEL
Mohyin, Kachin State

Truss 3
TRUSS SECTION

1/4" = 1'
S.49
25.8.2015

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 38)
2 3 4 5 6 7 8 9

12'-0" 12'-0" 12'-0" 24'-0" 12'-0" 12'-0" 12'-0"

15
7 "
20'-
715"
( +57'- 10" ) Design specifications for steel truss;
20'- 16 16

1"

A 36 steel

16 "
11 1
11

2
6'-8"
9'-

6'-8"
6'- 16

7'-
5'-28"

2
13 "
7
5'-2
3'-93"
8
4'-

"
fy = 36 ksi
3"

16"
2'-315
3'-6 9
16 "

( +50'- 6" )
( +50'- 0" ) ROOF FLOOR LEVEL fu = 58 ksi
Truss-4 (more detail see in pg.43) E 70 Electric Welding
FEXX= 70 ksi
2 3 4 5 6 7 8 9

12'-0" 12'-0" 12'-0" 24'-0" 12'-0" 12'-0" 12'-0"

Government of Kachin State


15
7 "
20'- 16
8'-5 5
16 "
( +57'- 10" )

6'- 13
16 "
2

2"
5'-
2'-6"

( +50'- 6" )
( +50'- 0" ) ROOF FLOOR LEVEL Mohyin, Kachin State
Truss-5 (more detail see in pg.44)
2 3 4 5 6 7 8 9

12'-0" 12'-0" 12'-0" 24'-0" 12'-0" 12'-0" 12'-0"


COMPOUND OFFICE
( +57'- 10" ) 4-STOREYED R. C. BUILDING
5"
12'-2 8

8"
3'-93
( +50'- 6" )
( +50'- 0" ) ROOF FLOOR LEVEL
Truss-6 (more detail see in pg.45)
B C D E F G H I

12'-0" 12'-0" 10'-0" 12'-0" 12'-0" 12'-0" 12'-0"

Mohyin, Kachin State


7
7 "
20'- 8
( +57'- 10" )

8'-
10 8
1"

2"
5'-
2"
3'-71

( +50'- 6" )
( +50'- 0" ) ROOF FLOOR LEVEL TRUSS SECTION
Truss-7 (more detail see in pg.46)
B C D E F G H I

12'-0" 12'-0" 10'-0" 12'-0" 12'-0" 12'-0" 12'-0"


3/64" = 1'
S.50
25.8.2015
15
7 "
8'-4 9
16 " ( +57'- 10" )
20'- 16 12'- 3
3 "
8
4"
6'-71

( +50'- 6" )
( +50'- 0" ) ROOF FLOOR LEVEL
Truss-8 (more detail see in pg.47)

B C D E F G H I

12'-0" 12'-0" 10'-0" 12'-0" 12'-0" 12'-0" 12'-0"

( +57'- 10" )
3
3 "
12'- 8

( +50'- 6" )
( +50'- 0" ) ROOF FLOOR LEVEL Daw Nan Kay Zar Wint
Truss-9 (more detail see in pg.48) U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 42)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

6 7 8 9
Government of Kachin State

Mohyin, Kachin State

12'-0" 12'-0" 12'-0"


COMPOUND OFFICE
4-STOREYED R. C. BUILDING

( +57'- 10" )
20'- 15
7
16 "

Mohyin, Kachin State

(+50'-0")ROOF
FLOOR LEVEL TRUSS SECTION
( +50'- 6" )

3/16" = 1'
S.51
25.8.2015

Truss 4

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 42)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

6 7 8 9 Government of Kachin State

Mohyin, Kachin State

12'-0" 12'-0" 12'-0" COMPOUND OFFICE


4-STOREYED R. C. BUILDING

( +57'- 10" )

Mohyin, Kachin State

2"
5'-
TRUSS SECTION
( +50'- 6" )
(+50'-0")ROOF
FLOOR LEVEL
3/16" = 1'
S.52
25.8.2015

Truss 5

For Detail E
see Page. no. 51

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 42)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

Government of Kachin State

6 7 8 9 Mohyin, Kachin State

12'-0" 12'-0" 12'-0" COMPOUND OFFICE


4-STOREYED R. C. BUILDING

( +57'- 10" )

Mohyin, Kachin State

8"
3'-93
TRUSS SECTION
( +50'- 6" )
(+50'-0")ROOF
FLOOR LEVEL 3/16" = 1'
S.53
25.8.2015

Truss 6

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 42)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi
F G H I

Government of Kachin State

12'-0" 12'-0" 12'-0" Mohyin, Kachin State

COMPOUND OFFICE
4-STOREYED R. C. BUILDING

( +57'- 10" )
8'-
10 8

Mohyin, Kachin State


1"

2"
5'- TRUSS SECTION
( +50'- 6" )
(+50'-0")ROOF
FLOOR LEVEL
3/16" = 1'
S.54
25.8.2015

Truss 7

For Detail F, G & H


see Page. no. 51

TU1 = 4"x2"x 81" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 42)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

B C D E
Government of Kachin State

Mohyin, Kachin State


12'-0" 12'-0" 10'-0"
COMPOUND OFFICE
4-STOREYED R. C. BUILDING

( +57'- 10" )
8'-4 9
16 "

15
7 " Mohyin, Kachin State
20'- 16
6'-74"
1

TRUSS SECTION

( +50'- 6" )
(+50'-0")ROOF
3/16" = 1'
FLOOR LEVEL
S.55
25.8.2015

Truss 8

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


TRUSS SECTION
(Ref. from Pg. no 42)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi
F G H I

Government of Kachin State

Mohyin, Kachin State


12'-0" 12'-0" 12'-0"
COMPOUND OFFICE
4-STOREYED R. C. BUILDING

( +57'- 10" )

Mohyin, Kachin State

TRUSS SECTION

( +50'- 6" )
(+50'-0")ROOF
3/16" = 1'
FLOOR LEVEL
S.56
25.8.2015

Truss 9

TU1 = 4"x2"x 18" Tube


Daw Nan Kay Zar Wint
TU2 = 3"x2"x 81" Tube U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


STEEL SCHEDULE

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

Government of Kachin State

DIMENSION Mohyin, Kachin State

TYPES SECTION (mm) REMARK


L B Thickness
(mm) (mm) (mm) COMPOUND OFFICE
4-STOREYED R. C. BUILDING

TU1 Tube 75 x 50 75 50 4

TU2 Tube 100 x 50 100 50 4

Mohyin, Kachin State

STEEL SCHEDULE

3/4" = 1'
S.57
25.8.2015

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


EXAMPLE OF CONNECTION DETAIL

Detail-A Detail-B
Ref. from page No. (39) Ref. from page No. (39)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
fu = 58 ksi
E 70 Electric Welding
FEXX= 70 ksi

TU1 Cleat Angle


25 x 25 x 50 x 4 mm Government of Kachin State
TU1

Mohyin, Kachin State


TU1
TU1

2-12mm Bolt & Nut


embedded length (12")

TU1
COMPOUND OFFICE
4-STOREYED R. C. BUILDING

Detail-C Detail-D Mohyin, Kachin State


Ref. from page No. (39) Ref. from page No. (39)

EXAMLE OF CONNECTION
DETAILS

Cleat Angle 1" = 1'


25 x 25 x 50 x 4 mm S.58
TU2

TU1 25.8.2015
Cleat Angle
25 x 25 x 50 x 4 mm
2
TU

TU1

2
TU
TU1 TU1

TU2

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


EXAMPLE OF CONNECTION DETAIL

Detail-E Detail-F
Ref. from page No. (44) Ref. from page No. (46)

Design specifications for steel truss;


A 36 steel
fy = 36 ksi
Cleat Angle fu = 58 ksi
25 x 25 x 50 x 4 mm Cleat Angle E 70 Electric Welding
25 x 25 x 50 x 4 mm FEXX= 70 ksi
TU1
TU1

TU1 Government of Kachin State


TU2
2

TU2
TU

Mohyin, Kachin State

TU
2

TU1
COMPOUND OFFICE
4-STOREYED R. C. BUILDING

Detail-G Detail-H Mohyin, Kachin State


Ref. from page No. (46) Ref. from page No. (46)

EXAMLE OF CONNECTION
DETAILS

Cleat Angle
25 x 25 x 50 x 4 mm
2
TU
TU1

1" = 1'
S.59
TU
2

TU1 25.8.2015
TU1

TU1 TU1

2
TU

TU
2
Cleat Angle

TU2
25 x 25 x 50 x 4 mm

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


FOOTINGS SCHEDULE

Size Min :
Type Bottom Main Steel Distribution Steel Remark
L (ft) B (ft) H (in.) Cover

F1 5 5 12 16mm@6"c/c Spacing ( Shorter Dir) 16mm@6"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis
Design specifications for foundation;
fc' = 2500 psi
F2 6 6 14 16mm@6"c/c Spacing ( Shorter Dir) 16mm@6"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis fy = 50000 psi (Main reinf.)
fy = 50000 psi (Temp. & shri. reinf.)
See " Structural Specifications and
F3 7 7 14 16mm@6"c/c Spacing ( Shorter Dir) 16mm@6"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis Parameters" for more information.

F4 8 8 14 18mm@4"c/c Spacing ( Shorter Dir) 18mm@4"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis
Government of KaChin State

F5 9 9 16 18mm@4.5"c/c Spacing ( Shorter Dir) 18mm@4.5"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis
Mohyin State

F6 10 10 18 18mm@4.5"c/c Spacing ( Shorter Dir) 18mm@4.5"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis

F7 11 11 22 20mm@5"c/c Spacing ( Shorter Dir) 20mm@5"c/c Spacing ( Longer Dir) 0'-2" Below Netural Axis COMPOUND OFFICE
4-STOREYED R. C. BUILDING

F8 5 8 18 18mm@4.5"c/c Spacing ( Shorter Dir) 18mm@4.5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA

F9 7 10 22 20mm@5"c/c Spacing ( Shorter Dir) 20mm@5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA

F10 7 17 22 20mm@5"c/c Spacing ( Shorter Dir) 20mm@5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA

Mohyin, Kachin State


F11 7 18 22 20mm@4.5"c/c Spacing ( Shorter Dir) 20mm@4.5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA

F12 11 17 22 20mm@4.5"c/c Spacing ( Shorter Dir) 20mm@4.5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA FOOTINGS SCHEDULE

F13 9 19 22 20mm@4"c/c Spacing ( Shorter Dir) 20mm@4"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA
1/4" = 1'
F14 20 10 22 20mm@5"c/c Spacing ( Shorter Dir) 20mm@5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA S.60
25.8.2015

F15 18 16 22 20mm@5"c/c Spacing ( Shorter Dir) 20mm@5"c/c Spacing ( Longer Dir) 0'-2" Below and Above NA

Note ( 1 ) Please use only sandy soil as backfill material, if have, all water from foundation holes must be first.
Note ( 2 ) At least 3" of Sand and Chipping layer must be applied on soils. After compacting, hardcore crushed stone is 1 foot under 5"
lean concrete.
Note ( 3 ) Concrete quality control is critical because, in design, concrete strength is the most important property to prevent shear failure
in footing.
Note ( 4 ) Combined and Mat footings must be provided both below and above Neutral axis. Daw Nan Kay Zar Wint
U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


R. C. COLUMNS SCHEDULE & SECTION

Tie Arrangement Details Design specifications for columns;


fc' = 2500 psi
Longitudinal (main)
fy = 50000 psi (Main reinf.)
Type Size , in. Reinforcement Remarks
fy = 40000 psi (Ties)
(no. - size)
Hoop/Crosstie Pieces See " Structural Specifications and
Tie Arrangement in Longitudinal Direction
per Set of Tie Parameters" for more information.

C1a 12" x 12" 8-16d 1 hoop A-8d@6" + x-8d@12" + B-8d@6" Square Col. Government of Kachin State

C1b 12" x 12" 8-18d 1 hoop A-8d@6" + x-8d@12" + B-8d@6" Square Col.
Mohyin, Kachin State

C2a 14" x 14" 8-18d 1 hoop A-10d@6" + x-10d@12" + B-10d@6" Square Col.

COMPOUND OFFICE
C2b 14" x 14" 12-18d 1 hoop A-10d@6" + x-10d@12" + B-10d@6" Square Col.
4-STOREYED R. C. BUILDING

C2c 14" x 14" 16-18d 2 hoops A-10d@6" + x-10d@12" + B-10d@6" Square Col.

Prop 10" x 10" 4-16d 1 hoop A-8d@6" + x-8d@12" + B-8d@6" Square Col.

Mohyin, Kachin State

R. C. COLUMN
Note: For example, (1) A-10d@6" + x-10d@12" + B-10d@6" means A spaces of 10 mm diameter ties at 6 in. c/c for a length of l0 at the base and B spaces of 10 mm diameter ties at 6 in. c/c for a length of l0 at the top of the
unsupported column length and the remaining length of the column is to be filled up with x spaces of 10 mm diameter ties at 12 in. c/c where x is the variable. SCHEDULE

(3) l0 is the largest of column dimensions, clear height / 6 and 18".


3/8" = 1'
S.61
25.8.2015

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group


For the correct position of columns with respect to grid lines, please consult the architect or refer to the latest architectural drawings.
Ph. 01-652831 ; 651165-2425
R. C. COLUMNS SECTION (by Type)

Design specifications for columns;


fc' = 2500 psi
fy = 50000 psi (Main reinf.)
Type : C1a Type : C1b
Type : C2a fy = 40000 psi (Ties)
Size : 12" x 12" Size : 12" x 12"
Size : 14" x 14" See " Structural Specifications and
Parameters" for more information.
12"

12"

14"
Government of Kachin State
12" 12"
14"
Mohyin, Kachin State
Main reinf. : 8 - 16d , Main reinf. : 8 - 18d ,
Ties: 8d ( 1 hoop ) per set Ties: 8d ( 1 hoop ) per set Main reinf. : 8 - 18d ,
Ties: 10d ( 1 hoop ) per set
See more details in columns schedule. See more details in columns schedule.
See more details in columns schedule.
COMPOUND OFFICE
4-STOREYED R. C. BUILDING

Mohyin, Kachin State

R. C. COLUMN
SECTION ( by Type )

Type : C2b
Type : C2c Type : Prop
Size : 14" x 14" 3/8" = 1'
Size : 14" x 14" Size : 10" x 10"
S.62
25.8.2015
14"

14"

10"
14" 10"
14"

Main reinf. : 12 - 18d ,


Main reinf. : 16 - 18d , Main reinf. : 4 - 16d ,
Ties: 10d ( 1 hoop ) per set
Ties: 10d ( 2 hoops ) per set Ties: 8d ( 1 hoop ) per set
See more details in columns schedule.
See more details in columns schedule. See more details in columns schedule.

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425


R.C. FLOOR BEAMS SCHEDULE

Top Reinforcement (No. & Size) Bottom Reinforcement (No. & Size) Mid Steel Stirrup Spacing (in.)
Type Size (No. & Remarks
Size)
Left Mid Right Left Mid Right Left Mid Right

B1a 10" x 14" 3-18d 3-18d 3-18d 3-18d 3-18d 3-18d - 8d @ 3" 8d @ 4" 8d @ 3"

B1b 10" x 14" 4-18d 4-18d 4-18d 4-18d 4-18d 4-18d - 8d @ 3" 8d @ 4" 8d @ 3"

B2 10" x 16" 4-18d 4-18d 4-18d 4-18d 4-18d 4-18d - 10d @ 3" 10d @ 5" 10d @ 3"

B3a 10" x 20" 3-20d 3-20d 3-20d 3-20d 3-20d 3-20d 2-12d 10d @ 3" 10d @ 4" 10d @ 3" Government of Kachin State

B3b 10" x 20" 5-20d 3-20d 5-20d 5-20d 5-20d 5-20d 2-12d 10d @ 3" 10d @ 4" 10d @ 3"
Mohyin, Kachin State

COMPOUND OFFICE
4-STOREYED R. C. BUILDING

EXAMPLE - 1 FOR TYPE B1a


LOCATION - Grid line 7 [ Ground Floor Level (+1'-6") ]

3-18d 3-18d 3-18d

Mohyin, Kachin State

2 3 4 R. C. BEAM
SCHEDULE
B1a B1a

12'-0" 12'-0" 3/64" = 1'


S.63
25.8.2015

3-18d X1 3-18d 3-18d

14"
3-18d X1 3-18d

3-18d
10"
28" 28" 28" 28"
8d @ 4" 8d @ 4"
8d @ 3" 8d @ 3" 8d @ 3" 8d @ 3"
Section X1-X1

Daw Nan Kay Zar Wint


3-18d 3-18d 3-18d U Lin Htet Han

P PIONEER Structural Design Group


Note : 1. As an example, 18d means 18mm diameter bar.
2. Where secondary beam crosses the main beam, provide 4 hanger stirrups, 2 inside the main reinforcement of secondary beam and the rest about 2" outside of secondary beam surface, one on each side. Ph. 01-652831 ; 651165-2425
SLABS & STAIRS SCHEDULE

SLABS SCHEDULE Design specifications for slab;


fc' = 2500 psi
fy = 50000 psi (Main reinf.)
Top Steel ( contd. edge ) Top Steel ( discontd. edge )
fy = 50000 psi (Temp. shri. reinf.)
Bottom Steel

Type Thickness
One-way/ Two-way/
Direction Remarks
See " Structural Specifications and
Cantilever Parameters" for more information.
Middle Strip Column Strip Middle Strip Column Strip Middle Strip Column Strip

Shorter 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c
Government of Kachin State
S1 4" Two-way
Longer 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c

Mohyin, Kachin State


Shorter 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c
S2 4" One-way
Longer 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c

Shorter 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c
COMPOUND OFFICE
S3 5" Two-way
4-STOREYED R. C. BUILDING
Longer 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c 10d @ 8" c/c

Note; No cutoff of top steel for all slabs exposed to weather

Mohyin, Kachin State

SLAB & STAIR


SCHEDULE
STAIRS SCHEDULE

Type Thickness One-way / Cantilever Top Steel ( contd. edge ) Bottom Steel Top Steel ( discontd. edge ) Distribution Steel Remarks
3/64" = 1'
S.64
25.8.2015
ST-1 6.5" Oneway 10d @ 6" c/c 10d @ 6" c/c 10d @ 6" c/c 10d @ 6" c/c

Daw Nan Kay Zar Wint


U Lin Htet Han

P PIONEER Structural Design Group

Ph. 01-652831 ; 651165-2425