SMART analyzers and sensors Each SMART pH sensor comes Data stored in the sensor includes:
eliminate one of the largest with factory calibration > Slope
problems with measuring pH – embedded in the sensor’s
> Reference Offset
field calibration. Traditional memory. Simply connect the
calibration methods require haul- sensor to a Rosemount Analytical > Glass Impedance
ing buffers and rinse solutions SMART analyzer and automatical- > Reference Impedance
from the lab to the installation ly upload the latest settings. > Time Stamp
point. Now with Rosemount With SMART, you’ll always get no > Sensor Serial Number
Analytical SMART technology, muss, no fuss calibration.
> Manufactured Date
calibration is truly plug and play.
Calibration solutions and equipment must be Buffers and equipment remain in lab – take only
taken to process location the calibrated sensors to process location
Difficult to schedule calibrations and record data Calibrate in advance – store until needed
Multiple analyzers, each requiring different SMART and standard sensors can be used on
sensor models. older Rosemount Analytical instrument models
1055, Xmt, 54, 54e, 81, 3081, 4081, 5081 and
newer models 56, 1056, 1057 and 6081.
2
SMART ANALY TICAL INSTRUMENTS SMART pH SENSORS
WITH MULTI-PARAMETER CAPABILITIES READY FOR ANY JOB
Model 56 Advanced
Dual-Input Analyzer
WIRELESS TRANSMITTER
Model 6081 features these
SMART capabilities:
Rugged Sensors
> Quick Start automatic recognition of
SMART pH sensor to facilitate startup The TUpH family of
sensors is your choice
> Compatible with both conventional for coating, high
pH and ORP sensors with and without solids content
integrated preamplifier applications of
a viscous
> Automatic calibration upon live nature with
Model 6081 Wireless connection to Rosemount Analytical the potential for
pH Transmitter SMART pH sensors with upload of plugging.
stored calibration data
3
SENSOR DIAGNOSTICS
REAL-TIME MONITORING KEEPS YOU INFORMED
pH probes require careful monitoring for proper > Faults and Warnings – set points for faults and
functioning and to give the user a good understand- warnings can be programmed from the host or at
ing of the process effects on the probe. the measurement point.
> View live diagnostics – glass impedance is used to > pH slope reflects the pH sensitivity of the glass
evaluate sensor condition and performance which electrode.
can indicate coating and exposure to high temper-
> mV offset is the cumulative error of the reference
ature. Reference impedance and mV input can
cell. High offsets are indicative of coating or
indicate coating, poisoning and high temperature.
poisoning conditions in the process.
Sensor data transferred to analyzer Sensor calibration time and method Sensor calibration diagnostics
BENCHTOP CALIBRATOR
IDEAL FOR REMOTE CALIBRATION OF pH SENSORS
pH calibration is one of the most the calibration information has push pin connectors for quick
difficult procedures to accurately been uploaded into the process easy connectivity. The system can
perform due to factors such as analyzer, the pH measurement calibrate SMART or non-SMART
extreme environmental temp- can be used to monitor or control enabled sensors.
eratures; individual sensor the process. Calibrating pH
For more information refer to PDS
performance issues; buffer sensors in a lab area, instead of
71-BTC.
temperatures; and operator tech- out in the plant can:
nique. The BenchTop calibrator
> Save time
allows the user to control the
environment during pH sensor > Reduce calibration errors
calibration ensuring an accurate > Limit the amount of calibration
calibration every time. solution used
Now maintenance personnel can The BenchTop calibrator uses the
calibrate all their pH sensors in a dual input Model 1056 SMART
controlled environment, then take analyzer mounted in a corrosion
the sensors out into the plant for resistant stand and pre-wired
insertion into the process. Once with both a Variopol cable and
4
USE SMART SENSORS IN THE CONFIGURATION
THAT BEST SUITS YOUR NEEDS
The SMART Sensor System The available calibration methods > Manual Entry – slope and offset
using SMART Sensors and Models > Factory Reset of stored
Automatic upload of factory 56, 1056, 1057 or wireless Model calibration data only
calibration data to the analyzer 6081 analyzer are:
Historical readings, or trending,
allows immediate live process allows technicians to predict
measurements. Slope, offset, > Auto Buffer – two point
appropriate maintenance frequency
reference impedance, glass > Manual Buffer – two point
and estimate probe life for specific
impedance and associated time > Standardize – one point probe in a specific process.
stamp are all uploaded.
SMART-capable analyzers are compatible with both SMART and non-SMART sensors
5
MORE ANALY TICAL SOLUTIONS FROM
EMERSON PROCESS MANAGEMENT
Emerson is the world’s largest provider of gas chromatography, process gas, combustion and environmental analysis solutions.
Emerson's Rosemount Analytical Liquid Division provides technologies and services for the analysis of liquid processes. For a wide range of applications,
Emerson provides more than 60 years of expertise in high-precision analytical sensors, instrumentation and services. For information, call 800.854.8257.
Emerson Process Management, Rosemount Analytical, ENDURANCE and PUR-Sense are marks of Emerson Process Management group of companies. All
other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure its accuracy, they are not to
be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
© Rosemount Analytical Inc. 2011. All rights reserved. Printed in the U.S.A.
www.raihome.com
Online ordering available.
91-6038 10.11