Project : DESIGN IV Project : Design IV Project : DESIGN IV

CALCULATION AND Doc. No : 05 - 42 15 005 - BG Doc. No. : 08 - 42 15 005 - BL


CALCULATION AND Doc. No : 07 - 42 15 005 - FI requirement Pump data Choosen(TAIKO PUMP)
SPECIFICATION OF BILGE TECHNICAL SPECIFICATION OF BALLAST SYSTEM SPECIFICATION OF FIRE System
Rev. No : Rev. No. : Rev. No : Q(m3/h) H(m) Type Q(m3/h) H(m) Power(kw)
SYSTEM MAIN SYSTEM
Page : 01 Page :1 Page : 01 BG (Bilge) 138.5 33.7 VS-150 140 35 22
BL(Ballast) 187.86 35.45 VS-200 190 40 37
1. LIST OF CODE/ REFERENCES USED 1. LIST OF CODE / REFERENCE USED 1. LIST OF CODE/ REFERENCES USED FI (Fire Mai 140 85.1 VS-150B 95 88 60
- LR Rules and Regulation a. Lloyd Rules and Regulation 2012 ( Part 5, chapter 13, section 11 ) - Lloyd Rules and Regulation 2012 VS-250B 190 90 110
- Roy L Harrington, Marine Engineering b. Roy L. Harrington, Marine Engineering - SOLAS 2009, Chapter II-2, Construction - Fire Protection, fire detection, and fire extinction
- Pompa dan Kompresor Ir. Sularso, MSME c. Machinery Outfitting Design Manual Vol. I - Pompa dan Kompresor Ir. Sularso, MSME
Pump Pump Minimum Spec Pump data Choosen(TAIKO PUMP)
2. CALCULATION ALGORITHM 2. CALCULATION ALGORITHM 2. CALCULATION ALGORITHM Numb Name Q(m3/h) H(m) Q(m3/h) H(m) Power(kw)
- Calculation of main bilge line a. Calculation volume displacement - Calculation of Fire Main Pipe 1 BG 138.5 33.7 140 35 22
- Calculation of branch bilge suction b. Calculation Displacement - Calculation of Fire Main Pump Capacity 2 BG 138.5 33.7 140 35 22
- Calculation capacity of bilge pump c. Calculation capacity of ballast pump - Calculation of Fire Main Pump Head 3 BL 187.86 35.45 190 40 37
- Calculation head of bilge pump d. Calculation of the main pipe diameter ballast - Head calculation in Engine Room installation 4 BL 187.86 35.45 190 40 37
- Calculation of head in suction line e. Calculation of head ballast pump - Head calculation of suction pipe 5 FI 140 85.1 95 88 60
- Calculation of head in discharge line - Calculation instalation at engine room - Head calculation of discharge pipe 6 FI 140 85.1 95 88 60
- Calculation of head losses - Calculation of head at the suction pipe - Head calculation of major and minor losses Total 238
- Calculation bilge pump spesification - Calculation of head at the discharge pipe - Calculation of Emergency Fire Pump Pump Pump Minimum Spec Pump data Choosen(TAIKO PUMP)
- Calculation bilge well volume - Calculation of head losses Numb Name Q(m3/h) H(m) Q(m3/h) H(m) Power(kw)
3. INPUT DESIGN PARAMETER 1 BG+BL 187.86 35.45 190 40 37
3. INPUT DESIGN PARAMETER 3. INPUT PARAMETER DESIGN - Calculation of Fire Main Pump 2 BG+BL 187.86 33.7 190 40 37
- Calculation of main bilge line a. Calculation volume displacement Qbg = Capacity of Bilge Pump 3 FI 140 85.1 95 88 60
B : Greatest moulded breadth of ship, in metres L = Length of ship - Calculation of Fire Main Pipe 4 FI 140 85.1 95 88 60
D : Moulded depth to bulkhead deck, in metres B = Breadth of ship Qf = Capacity of Fire Main Pump Total 194
L : Rule length of ship T = Draft v = Fluid velocity in fire main pipe Pump Pump Minimum Spec Pump data Choosen(SILI PUMP)
- Calculation of branch bilge suction Cb = coefficient block - Head Calculation of Fire Main Pump Numb Name Q(m3/h) H(m) Q(m3/h) H(m) Power(kw)
C : Length of compartement, in metres b. Calculation Displacement - Calculation in Engine Room Installation 1 BG+FI 140 85.1 VS-250B 190 110
B : Greatest moulded breadth of ship, in metres ▼ = volume displacement hs : head statis pump 2 BG+FI 140 85.1 VS-150B 95 88
D : Moulded depth to bulkhead deck, in metres ρ = massa jenis air laut hp : head by pressure 3 BL 187.86 35.45 190 40 37
- Calculation capacity of bilge pump c. Calculation capacity of ballast pump hv : head by velocity 4 BL 187.86 35.45 190 40 37
dm : Rule internal diameter of main bilge line, in mm V = volume sea water for ballast - Calculation in suction line Total 272
- Calculation head of bilge pump t = time to empty ballast tank major los: head because length of sunction line Pump Pump Minimum Spec Pump data Choosen(TAIKO PUMP)
- Calculation of head in suction line d. Calculation main pipe of ballast minor los: head because accesoris in sunction line Numb Name Q(m3/h) H(m) Q(m3/h) H(m) Power(kw)
ν : Viscocity Q = capacity ballast pump - Calculation in discharge line 1 BL+FI 187.86 85.1 190 90 110
Rn : Reynold Number v = velocity major los: head because length of discharge line 2 BL+FI 187.86 85.1 190 90 110
λ : Friction losses e. Calculation of Ballast Pump minor los: head because accesoris in discharge line 3 BG 138.5 33.7 140 35 22
major losses : head because length of suction line e.1. Calculation instalation at engine room - Calculation of total head pump 4 BG 138.5 33.7 140 35 22
minor losses : head because accesoris in suction line hs = head statis pump hz : head statis pump Total 264
- Calculation of head in discharge line hp = head difference of pressure hp : head by pressure Pump Pump Minimum Spec Pump data Choosen(TAIKO PUMP)
ν : viskositas hv = head difference of velocity hl1 : suction head Numb Name Q(m3/h) H(m) Total 0 Power(kw)
Rn : Reynold Number e.2. Calculation head at suction pipe (hl1) hl2 : discharge head 1 BG+BL+FI 187.86 85.1 190 90 110
λ : friction losses ν = viskocity - Determine The Specification of Fire Main Pump 2 BG+BL 187.86 33.7 190 40 37
mayor losses : head because length of discharge line Rn = reynould number - Calculation of Emergency Fire Pumo 3 FI 140 85.1 95 88 60
minor losses : head because accesoris in discharge line λ = friction losses Qf = Capacity of Fire Main Pump Total 207
- Calculation of head losses major loss = head suction sidedue to pipe length Pump Pump Minimum Spec Pump data Choosen(TAIKO PUMP)
hz : static head minor loss = head because there are accessories to the suction pipe 4. OUTPUT DESIGN PARAMETER Numb Name Q(m3/h) H(m) Q(m3/h) H(m) Power(kw)
hp : head by pressure e.3. Calculation of head at the discharge pipe (Hl2) - Fire main pump capacity 1 BG+BL+FI 187.86 85.1 190 90 110
hl1 : suction head ν = viskosity - Fire main pipe diameter 2 BG+BL+FI 187.86 85.1 190 90 110
hl2 : discharge head Rn = reynould number - Fire main pipe specification Total 220
- Calculation bilge pump spesification λ = friction loss - Emergency fire pump capacity
- Calculation bilge well volume major loss = head suction sidedue to pipe length
minor loss = head because there are accessories to the discharge pipe 5. DETAIL CALCULATION
4. OUTPUT DESIGN PARAMETER Project : Design IV a. Calculation of Fire Pump Capacity
According SOLAS Chapter II-2 Regulation 10 part 2.2 abouut fire
- Diameter of main bilge line Doc. No. : 08 - 42 15 005 - BL pump, mention that the total capacity of fire pump not to be less
TECHNICAL SPECIFICATION OF BALLAST SYSTEM
- Diameter of branch bilge suction Rev. No. : than 4/3 from capacity bilge pump, so capacity fire pump is :
- Capacity of bilge pump Page :2 Qf = 4/3 Qbg
- Head of bilge pump = 4/3 ( 92.16Where,
) Q bg is = 92.16 m³/h
- Head in suction line f. Calculation of total head losses (Hl) = 122.88 m³/h
- Head in discharge line hs = static head pump = 0.03 m³/s SOLAS 2009, Chapter II, Regulation 10 Part 2.2
- Head losses hp = head differential pressure
- Calculation of bilge pump specification hl1 = head in the suction pipe
- Calculation bilge well volume Hl2 = head in the discharge pipe Project : DESIGN IV
CALCULATION AND
Doc. No : 07 - 42 15 005 - FI
SPECIFICATION OF FIRE
Project : DESIGN IV 4. OUTPUT PARAMETER DESIGN Rev. No :
CALCULATION AND MAIN SYSTEM
Doc. No : 05 - 42 15 005 - BG a. Calculation volume displacement Page : 02
SPECIFICATION OF BILGE
Rev. No : ▼ = volume displacement Number of fire main pump for cargo ship with 1000 gross tonnage or above is at least 2 pumps
SYSTEM
Page : 02 b. Calculation Displacement SOLAS 2009 : Chapter II, Section 2, Regulation 10, 2.2.2
Δ = displacement
5. CALCULATION DETAIL c. Calculation capacity of ballast pump b. Calculation of Fire Main Pipe Diameter
Q = capacity ballast pump Qf = A x v
a. Calculation of main bilge line d. Calculation diameter main pipe ballast = 1/4 x π x D² x vf
dm = mm LR 2011 Rules and Regulation, part 5, chapter 13.5 dH = diameter main pipe of ballast D² = 4 x Qf
e. Calculation of ballast pump π x vf
(4x
Where : - Calculation instalation at engine room =
(0,03
3,14 )x
L = Lpp Where,96% Lwl = 105.6 m hs = static head pump
3)
= 110 m 97% Lwl = 106.7 m hp = head differential pressure = 0.014 m
B = 18 m so, L used is 97%Lwl hv = head differential of velocity D= 0.120 m
D = 7.2 m - Calculation head at suction pipe (hl1) = 120 mm
Internal diameter of main bilge pipe is not ot be less than 50 mm hl1 = head at suction pipe
dm = - Calculation head di at discharge pipe (hl2) Then for fire main pipe, it will be use stell galvanized pipe according to JIS G 3452 Standart
= 1.68√106.7(18+7.964) + 25 hl2 = head at discharge pipe Inside diameter (dm) = 126.6 mm
= 112.11 mm f. Calculation total head losses (Hl) thickness = 6.6 mm
Hl = total head losses Outside diameter = 139.8 mm
Then for bilge main pipe, it will be use carbon stell galvanized pipe according to JIS Standart Nominal pipe size = 125A mm schedule - 40
Inside diameter (dm) = 126.6 mm 5. CALCULATION DETAILS Min. thickness (L.R Regulation) = 4.5 mm (LR 2011 Rules and Regulation,
thickness = 6.6 mm Lpp : 110 m L/ B = 6.111 part 5, chapter 12, table 12.2.4)
Outside diameter = 139.8 mm Lwl : 113.3 m B / L= 0.164
Nominal pipe size = 125A schedule - 40 Bmld : 18.0 m T/ L= 0.065
minimum thickness (L.R Regulation) = 4.5 mm (LR 2011 Rules and Regulation, Hmld : 9.2 m Lcb = 0.64 c. Calculation of Fire Main Pump Head
part 5, chapter 12, table 12.2.4) T : 7.20 m Head Statis Pump
b. Calculation of main bilge branch pipe Vs : 16.0 Knot Hz = Distance from pump to navigation room
db = mm : 8.230 m/s = 22 m
LR 2011 Rules and Regulation, part 5, chapter 13.6
ρ : 1.025 ton / m3 (density of sea water) SOLAS 2012, Chapter II Part C, Regulation 10 Part 2.1.6
Where : υ : 0.00000119 m2 / s (viscosity of sea water) Head because different of pr= 25 m
C = Length each Compartemen g : 9.81 m / s2 Head because different velocity
= 21.00 m Route : Tanjung Perak - Benchamas Terminal Thailand hv = (v2dis - v2suc0 m (v dis = v suc)
B= 18 m
D= 7.2 m Calculation at Suction Pipe (hl1)
head cause friction at suction pipe
db = Reynold number (Rn) :
= 2.15 √18.2 (18 + 7.964) + 25 viscocity 0.822 cst at 30o 0.000000822 m2/s
= 74.46 mm Rn = v . D / υ
Rn = 0.00013 Kind of flow characTurbulen
Then for bilge branch pipe, it will be use carbon stell galvanized pipe according to JIS Standart Use formula = 0,02+0,0005/D
Inside diameter (db) = 75.9 mm then cold be known the fricti0.02+0.0 0.02
thickness = 6.6 mm Length of pipe ( L ) 18 m
Outside diameter = 89.1 mm Project : Design IV a. Major losses (hf) =
Nominal pipe size = 80A mm schedule - 40 Doc. No. : 08 - 42 15 005 - BL λxLxv2 / 0.00155 m
TECHNICAL SPECIFICATION OF BALLAST SYSTEM
minimal thickness (L.R Regulation) = 4.5 mm (LR 2011 Rules and Regulation, Rev. No. :
part 5, chapter 12, table 12.2.4) Page :3 b. Minor losses (head cause piping accessories)
c. Calculation capacity of bilge pump No Type N k nxk
Q= 5,75 x ( dm²) a. Calculation of Volume displacement (▼) 1 gate valv 1 0.86 0.86
m3/s LR 2011 Rules and Regulation, part 5, chapter 13.6
10³ ▼ = L X B X T X Cb 2 SDNRV 3 1.23 3.69
where : = 110 x 18 x 7.2 x 0.64 3 Conjuncti 2 1.14 2.28
dm : inside diameter of bilge main pipe = 9397.555 m3 4 Strainer 4 1.14 4.56
: 126.60 mm Total 6.83
So, Q5.75
: x (126.60 2) b. Calculation of displacement ( ∆ ) Minor Losses (hl) = k total x v2 / (2g)
10³ ∆ = ▼x ρ = 6.83 x 3 ² / (2 x 9.8)
: 92.16 m3/h = 9397.55 x 1.025 = 3.136 m
: 0.026 m3/s = 9632.494 Ton
1.535975 m3/min Project : DESIGN IV
CALCULATION AND
Weight of ballast water (WB): Doc. No : 07 - 42 15 005 - FI
SPECIFICATION OF FIRE
Tanki Balast 1 terletak antara frame 139 - 155
MAIN SYSTEM Rev. No :
Project : DESIGN IV WL Area (m2 ) FS FS x A Page : 03
CALCULATION AND
Doc. No : 05 - 42 15 005 - BG 0 14.4537 1 14.4537 volume = 1/3 x Σ x h
SPECIFICATION OF BILGE
SYSTEM Rev. No : 0.6 25.4422 4 101.7688 = 61.38064 Calculation at Dischsrge Pipe (hl2)
Page : 03 1.2 37.2291 1 37.2291 Reynold number (Rn) :
Σ= 153.4516 Viscosity = 0.822 cst on 40 oC ### m2/s
d. Calculation head of bilge pump karena balass tank dibagi star bord dan port side maka volume ballas tank = 122.7613 m3 Rn = (Vs x ds) / n
- Calculation instalation in E/R = (3 x (0.2021))/0.0000008
H = Hs + HP + HV + total Head-loss (Pompa dan Kompresor Ir. Sularso, MSME hal 28) Tanki Balast 2 terletak antara frame 118 - 139 = ###
WL Area (m2 ) FS FS x A then the flturbulen use the formula = 0.0239
where 0 64.4473 1 64.4473 volume = 1/3 x Σ x h so that it can be seen friction losses (l)
Hs : distance from Suction Well to Overboard 0.6 79.9582 4 319.8328 = 193.2618 Mayor losses (hf) = f x L x v2 / ( D x 2g)
: 7.2 + 0.75 = 7.95 m 1.2 98.8743 1 98.8743 Pipe length (L) disc = 76.00 m
Hp : Different pressure in suction side and discharge side Σ= 483.1544
: ( Pdiscd - Psuct ) / ρg = ( 1 atm - 1 atm ) / 1,025 * 9,8 m karena balass tank dibagi star bord dan port side maka volume ballas tank = 386.5235 m3 Mayor los = 0.0224 x 110 x 3 2 / (0.204 x 2 x 9.8)
: 0 Because pressure in suction and discharge have same value = 6.602 m
Hv : Different flow velocity in suction side and discharge side Tanki Balast 3 terletak antara frame 97 - 118
: ( V2disch - V2suct ) / 2g = ( 3 m/s - 3 m/s ) / 2 * 9,8 m WL Area (m2 ) FS FS x A Minor losses (head because of the accessories that exist on the pipe)
: 0 m 0 92.9278 1 92.9278 volume = 1/3 x Σ x h No type N k nxk
0.6 108.2426 4 432.9704 = 259.649 1 Butterfly 1 0.86 0.86
- Calculation of head losses in suction line 1.2 123.2243 1 123.2243 2 SDNRV 2 1.23 2.46

Major lossesR:e = ( D x V ) / υ (Pompa dan Kompresor Ir.Sularso,MSME hal 28) Σ= 649.1225 3 Conjuncti 3 1.14 3.42
where : karena balass tank dibagi star bord dan port side maka volume ballas tank = 519.298 m3 Total 6.74
D : Inside diameter Main Pipe : 126.6 mm
V : flow Velocity : 3 m/s Tanki Balast 4 terletak antara frame 78 - 97 Minor Losses (hl) = k total x v2 / (2g)
u : 0.0000849/106 WL Area (m2 ) FS FS x A = 6.74 x 3 2 / (2 x 9.8)
: 8.49E-11 m2/s 0 84.6877 1 84.6877 volume = 1/3 x Σ x h = 3.095 m
Re: (0.151 x 3 ) / 8,49 x 10-11 if Re <2300,"laminer" 0.6 98.5356 4 394.1424 = 236.3939
: 4.47E+09 = turbulen if Re >2300,"turbulen" 1.2 112.1547 1 112.1547 Calculation of total head
Σ= 590.9848 Totales (Hl) = hs + hv + hp + hf1 + hl1 + hf2 + hl2
Major losses : λ x L x v^2 / (D x 2g) (Pompa dan Kompresor Ir.Sularso,MSME hal 28) karena balass tank dibagi star bord dan port side maka volume ballas tank = 472.7878 m3 = 25 + 0 + 27 + 0,0011+ 3.136 + 6.545 + 3.095
Where : = 64.500 m
λ : 0.02+0.0005/dm Tanki Balast 5 terletak antara frame 44 - 78
: 0.023949 WL Area (m2 ) FS FS x A Requirement of Pump
L : Length of Suction Side 0 20.4835 1 20.4835 volume = 1/3 x Σ x h Capacity ( = 122.88 m3/h
: 81 m 0.6 42.7553 4 171.0212 = 104.5277 Head = 64.50 m
v: 3 m/s 1.2 69.8146 1 69.8146 Main and stand by Fire pump specification
D: dm Σ= 261.3193 Merk : SILIPUMP (80CLH - 5.5)
: 126.60 mm karena balass tank dibagi star bord dan port side maka volume ballas tank = 209.0554 m3 Capacity : 150 m3/hr
Head : 65 m
Major losses ( hf ) : λ x L x v^2 / (D x 2g) Jadi total kapasitas Ballast tank (Vb) = 1710.426 m3 Rpm : 2900 RPM
: 0.023 x 68 x 32 / (0.126 x 2 x 9.8) Power : 45.0 kW
: 7.04 m Project : Design IV
Doc. No. : 08 - 42 15 005 - BL d. Emergency Fire Pump calculation
TECHNICAL SPECIFICATION OF BALLAST SYSTEM
Minor losses (hm) : head because accesoris in suction line Rev. No. : Main Fire pump capa150.00 m3/hr
No. Accesoris n k nxk Page :4 based on SOLAS reg 4 point 4.3.3.2.1
1 Elbow 90 o 5 0.7 3.5 Wb = Vb x ρ SW Capacity of emergency fire p 40% from required total capacity,
2 Butterfly valve 8 0.6 4.8 = 1710 x 1.025 So, total capacity for emerg 60 m3/hr
3 SDNRV 1 2 2 = 1753.187 Ton Based on data above, we could choose specification pump bellow :
4 T joint 3 1.8 5.4
5 Strainer 2 0.58 1.16 c. Calculation of capacity ballast pump Project : DESIGN IV
Σ 16.86 Volume is planned to be vacated in time = 7 hour
CALCULATION AND Doc. No : 07 - 42 15 005 - FI
SPECIFICATION OF FIRE
So this capacity is Rev. No :
MAIN SYSTEM
Q = V/ t Page : 04
= 1699/9
= 244.347 m3/hr = 0.068 m3/s Pump Head calculation
Pump statical head= 22 m
Project : DESIGN IV d. Calculation of diameter main pipe ballast Head cause differen= 25 m
CALCULATION AND
Doc. No : 05 - 42 15 005 - BG Q = Ax v Head cause different velocity
SPECIFICATION OF BILGE hv = (v2dis - v2suc)/2g =
SYSTEM Rev. No : 0 m (v dis = v suc)
Page : 04 which : - Calculation of head losses in suction line
A = area of pipe = π x D²/4 head cause friction at suction pipe
Minor losses : (Σ n.k) x v² /2g v = velocity ( 2 - 4) m/s, we use = 3 m/dt Reynold number (Rn) :
: 15,46 x 3² /(2x9.8) viscocity 0.822 cst at 30o 0.000000822 m2/s
: 7.74 m Q = Ax v Rn = v . D / υ
= π x dH2 / 4 x v Rn = 0.00013 Kind of flow characTurbulen
So, Head Loss in Suction Line dH = Q  4 Use formula = 0,02+0,0005/D
H = Major Head Loss + Minor Head Loss  v then cold be known the fricti0.02+0.0 0.02
= 14.78 m = ((0,048 x 4)/(3,14 x 3))^0.5 Length of pipe ( L ) 12.24 m
= 0.1698 m a. Major losses (hf) =
- Calculation of head losses in discharge line 0 = 169.77 mm λxLxv2 / 0.88808 m
Major losses (hf) : λ x L x v^2 / (D x 2g)
Major losses : λ x L x v^2 / (D x 2g) b. Minor losses (head cause piping accessories)
Where : : 0.023 x 10 x 3^2 / (0.202 x 2x9.8) Pipe the selected type of carbon steel galvanized, Schedule No.40 , JIS Standard : No Type N k nxk
λ : 0.02+0.0005/dm : 0.84 m Type = JIS G 3452 1 gate valv 1 0.86 0.86
: 0.0239 Nominal Pipe Size = 200 A 2 SDNRV 1 1.23 1.23
L : Length of Discharge Side Inside diameter = 199.9 mm 3 Strainer 1 1.14 1.14
: 10.0 Thickness = 8.2 mm Total 2.09
v: 3 Outside diameter = 216.3 mm
D: dm Minor losses = k total x v2 / (2g)
: 126.6 Project : Design IV Minor los2.09 x 3^2 / (2x9.8)
Doc. No. : 08 - 42 15 005 - BL 0.96 m
TECHNICAL SPECIFICATION OF BALLAST SYSTEM
Minor losses : head because accesoris in discharge line Rev. No. :
No. Accesoris n k nxk Page :5 Head Calculation at discharging pipe (hl 2)
1 Butterfly valve 1 0.6 0.6 Reynold number
2 T Joint 1 1.8 1.8 e. Calculation of ballast pump viscocity υ(Rn) :
= 0.822 t 30oC = 8E-07 m2/s
3 SDNRV 2 2 4 e.1. Calculation installation at engine room Rn = v . D / υ v = 3.0 m/s
Σ: 6.4 Head static (Hs) = T + 0.75 Rn = 462044
Hs = 7.95 m flow characteristic turbulen
minor losses : (Σ n.k) x v² /2g Head pressure (Hp) = (Pdis - Psuc)/γ
: 6.4 x 3² /(2x9.8) Hp = 0 m dimana : (1 atm - 1 atm) Then cold be known 0.02+0.0005/D
the fricti = 0.02395
: 2.94 m Head Velocity (Hv) due to the speed between the suction side and out the same then: Length of pipe ( L ) dischargi 174.00 m
Hv = (v2dis - v2suc)/2g Major losses (hf) = λxLxv2/(D x 2g) = 15.1146 m
So, Head Loss in Discharge Line = 0 m dimana : (v dis = v suc)
H = Major Head Loss + Minor Head Loss b. Minor losses (head cause piping accessories)
= 3.78 m e.2. Calculation of head losses at the suction pipe No Type N k nxk
Head due to friction in the suction pipe 1 Elbow 90 o 1 0.57 0.57
Reynold number (Rn) : 2 Butterfly 1 0.86 0.86
HEAD TOTAL = Hs + Hp + Hv + Σ head losses (suction and discharge) Viscosity = 0.822 cst on 30oC = 0.0000008 m2/s 3 SDNRV 1 1.23 1.23
= 7.784 + 0 + 0 + 14.40 + 3.78 ds = 199.9 mm 4 Conjuncti 1 1.14 1.14
= 26.50 m Rn = (Vs x ds) / n Total 3.8
= (3 x (0.2542))/0.0000008
e. Bilge Ballast Pump Spesification = 729562.0 ; then the flow is : turbulen Minor losses = k total x v2 / (2g)
Requirement of Pump use the formula = 0,02+0,0005/D Minor los 3.8 x 3^2 / (2x9.8)
Capacity ( = 92.16 m3/h so that it can be seen friction losses (l) = 0.0225 1.74 m
Head = 26.50 m Mayor losses (hf) = f x L x v 2 / ( D x 2g) HEAD TOTAL = Hs + Hp + Hv + Σ head losses (suction and discharge)
Pipe length (L) suction side is = 75 m = 53.08 m
Bilge Main Pump Spesification
Merk = SILI PUMP ( 100CLH - 15) Mayor losses (hf) = 0.0217 x 122 x 3 2 / (0.2979 x 2 x 9.8) Emergency Fire pump specification
Capacity = 100 m3/hr = 3.877 m Merk : SILIPUMP (50CLH-3.5)
Head = 30 m Minor losses (head because of the accessories that exist on the pipe) Type : centrifugal pump
Frekuenzi = 50 Hz No type N k nxk Capacity : 80 m3/hr
Rpm = 2900 rpm 1 SDNRV 1 1.23 1.23 Head : 62 m
Power = 15.0 kw 2 Butterfly valve 3 0.86 2.58 Rpm : 2900 RPM
material impeller and seal = copper 3 Gate Valve 1 1.15 1.15 Power : 22.0 kW
material shaft = stainless steel 4 elbow 90 1 0.75 0.75
material casing = copper 5 Filter 2 1.5 3
Project : DESIGN IV 7 Conjunction T 4 1.14 4.56
CALCULATION AND Doc. No : 05 - 42 15 005 - BG Total 13.27
SPECIFICATION OF BILGE
Rev. No :
SYSTEM
Page : 05 Minor Losses (hl) = k total x v2 / (2g)
= 16.5 x 3² / (2 x 9.8)
f. Calculation of bilge well volume = 6.093 m
Volume bilge well is not less than 0.15 m³ LR 2011 Rules and Regulation, part 5, chapter
13.7 Project : Design IV
Planning Bilge Well Dimension : Doc. No. : 08 - 42 15 005 - BL
TECHNICAL SPECIFICATION OF BALLAST SYSTEM
Length : 0.7 m Rev. No. :
Wide : 0.7 m Page :6
Height : 0.35 m
So, volume is : 0.1715 m³ e.3. Calculation of head at the discharge pipe
and, will be fitted : 16 bilge well Head due to friction in the suction pipe
Total Volume of Bilge Well : 2.744 m³ Reynold number (Rn) :
Viscosity = 0.822 cst on 40 oC = 0.00000082 m2/s
Rn = (Vs x ds) / n
= (3 x (0.02102))/0.0000008
= 729562.0 ; then the flow is : turbulen
use the formula = 0,02+0,0005/D
so that it can be seen friction losses (l) = 0.0225
Mayor losses (hf) = f x L x v 2 / ( D x 2g)
Pipe length (L) discharge side is = 10.000 m

Mayor losses (hf) = 0.0217 x 122 x 3 2 / (0.2979 x 2 x 9.8)


= 0.517 m

Minor losses (head because of the accessories that exist on the pipe)
No type N k nxk
1 Butterfly Valve 3 0.86 2.58
2 elbow 90 1 0.75 0.75
3 SDNRV 2 1.23 2.46
4 Conjunction T 4 1.14 4.56
Total 10.35

Minor Losses (hl) = k total x v2 / (2g)


= 6.93 x 32 / (2 x 9.8)
= 4.753 m

e.4. Calculation of total head


Total head losses (Hl) = hs + hv + hp + hf1 + hl1 + hf2 + hl2
= 8.71 + 0 + 0 + 5.222 + 6.424 + 5.222+ 3.182
= 23.19 m

f. Specification of Bilge Ballast Pump


Requirement of Pump
Capacity (Q) = 244.35 m3 /h
Head = 23.19 m

Merk = SILI PUMP ( 125CLH - 19)


Capacity = 280 m3/hr
Head = 25 m
Frequency = 50 Hz
Rpm = 2900 rpm
Power = 30.0 kw