VOLTAS LIMITED

DDUGJY- JVVNL-BHARATPUR-RAJASTHAN
ALL BLOCK QUANTITY ABSTRACT FOR SUBCONTRACTOR ERECTION
Sl. Total BOQ
Item Description Units Rate
No. Quantity
1 HT LINES 33 KV

2 Conducting route survey as per approved route map and Km


107.0000
pegging of route with section point/double pole location
3 Trimming of tree branches and preparing route appraoches per Km
107.0000 350
for the proposed line
4 Supply and erection of 9.0 mtrs long.(400 Kg.) PCC Poles in
allignment including excavation of pit size 1.2x0.6x1.5 cum.
for 9 mtrs PCC poles in ground and back filling soil 0.0000
consolidating each deposit layer of 0.15 mtr. by watering and
ramming etc. in the length.
4.1 In normal soil 1518.0000 No. 750
4.2 In ordinary rock/Hard Soil which does not require drilling 300.0000 No. 900
4.3 In ordinary rock/Hard Soil which require drilling 1.0000 No. 1150
5 Supply and fixing of 33 KV double pole line structure set
(Galvanized) on 9mtrs PCC poles for cut point complete on
existing poles in all respect as required made from M.S.
channel 100x50 X6 mm ISMC [9.56 kg. per mtr] ISA M.S. 107.0000 no. 280
angle 65x65x6 ,M.S. Angle 50x50x6 mm and M.S. flat 50x6
mm [excluding cost of pole] weight(130.338 kgs.) Approx

6
Supply and fixing of 33 KV Cross Arm with Top Hamper with
clamps (Galvanized) made of MS Angle 75x75x6mm, clamp 1605.0000 set 55
50X10 mm, earth clamp 50X6 mm (wt.=23.486 approx)
7 Supply and fixing 33 KV porcelain Pin insulator with Pin on
pole complete including all accessories like hardware fittings 5136.0000 no. 25
etc.
8
Supply and erection of 45 KN. porcelain disc.insulators for 33
KV ( each unit consisting of 3 disc insulators & one B&S Type 642.0000 no. 50
hardware) on brackets complete including all acessories etc.
9 Supply and Drawing of overhead steel cored aluminum
337.0500 Km 2000
ACSR Dog conductor in all respect
10
Supply and erection of PG clamps (For Dog) made of
aluminum alloy as per IS:617-1994 (with latest amendments
if any). All ferrous metal part intended for outdoor use except
642.0000 set 8
those made of stainless steel shall be protected by hot dip
galvanizing in accordance with IS 2633-1986(latest amended)
com plete in all respect as required for ACSR conductor,
11 Supply and erection of GI stay sets (Galvanized) complete
with 20 mm dia ,2.4 mtrs long stay rod and 380 x380x4mm
anchor plate including stay clamps 14mm turn buckle and GI
stay wire size 7/8 SWG tightened through 33 KV stay
0.0000
insulator including excavation of pit size 1.1x1.1x1.85 cum.in
ground and refilling with proper watering & ramming etc., as
required complete in all respect.

11.1 In all types of soil 1734.0000 set 350


11.2 In ordinary rock/Hard Soil which does not require drilling 405.0000 set 500
11.3 In ordinary rock/Hard Soil which require drilling 1.0000 set 750
12 Supply and erection of G. I. stay wire of 7/8 SWG
21.4000 MT 0
(Galvanized)
13
Supply and erection of 6 SWG GI Wire for continuous
earthing of 33 KV Line hot dip (Galvanised) as per technical 17.3340 MT 5000
specification, approved drawings and scope of work.
14 Supply and erection of earthing rod sets for S/S made with
MS Rod (Galvanized ) 20 mm dia, 3 meter length along with
321.0000 set 180
G.I wire 8 SWG (approx. total length / weight, 50 meter/4.907
Kg. ) .
15 Supply and erection of Danger plate of size 200 X 250 mm
1819.0000 no. 8
complete in all respect
16 Supply and erection of M.S, Nuts & Bolts (Galvanized) of
1926.0000 Kg 0
assorted size
17 33 KV SUB STATION / 33 KV Bay / 11 KV Bay 0.0000 0
18 Grass cutting and surface dressing including removal of Sq.Mtr
unwanted/rubbish plants with roots from open ground /yard
5000.0000 6
and other Nigam premises with stacking of grass/plants at
desired place near the ground.
19 Levelling of ground up to 30 cm.depth. with tractor and T&P Sq.Mtr
required as per condition of ground including removal of
25000.0000 8
rubbish plants from ground & marking of boundary with lime
powder.(Including all lead & lifting)
20 Supply and Loading & unloading and erection, testing and
commissioning of 3.15 MVA 33/11KV Copper wound Power
5.0000 No. 18000
Transformer complete with first filling of transformer oil , OFF
circuit tap changer and all fittings
21 Supply and erection of outdoor 11 KV O/D VCB KIOSK
complete with accessories including use of special tools &
conducting all pre commissioning tests before energisation, 283.0000 No. 2500
filling oil etc. complete in all respect with erection& grouting of
structure (excluding civil works).
22 Supply and erection of outdoor 36 KV O/D VCB KIOSK
complete with accessories including use of special tools &
conducting all pre commissioning tests before energisation, 10.0000 No. 3000
filling oil etc. complete in all respect with erection& grouting of
structure (excluding civil works).
23 Supply and fixing of 33/11KV S/S structure (Galvanized) on
existing PCC Poles including necessary nut & bolts &
clamps etc. steel wt. 4087 Kg. made of MS Channel 100x50, 5.0000 set 16000
MS Flat 50x6 and MS Sheet as per approved design and
drawing.
24 Supply , Laying, Testing Termination of control Cable of size
4 X 4 SQ.MM. 1100 Volts PVC Insulated including supply and
installation of ferrules to design various cores of control 2.8598 km 9000
cables by terminal no. of identification including utilisation of
cable gland.
25
Supply and Drawing of overhead steel cored aluminum
ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete 29.2000 Km 2000
in all respect as per latest specification and drawing
26 Supply and fixing of earth mesh (Galvanized) at sub-station
as per approved map & design using MS Flat 50 x 6 mm &
MS rod 20 mm dia including laying of flat at the depth 0.65
0.0000
mtr & MS rod at 3 metre depth Welding & jointing at joints,
structures & equipments etc. in switch yard area of 35 M x 35
M as per drawing (Galvanized)
27 Supply and laying of M.S. Flat 50 X 6 mm (Galvanized) for
5.5000 MT 6000
earthing
28 Supply and erection of earthing rod sets for S/S made with
1129.0000 set 180
MS Rod (Galvanized ) 20 mm dia, 3 meter length
29 Supply and Installation of 11 /0.4 KV 25 KVA Al wound,
conventional outdoor type distribution transformers with all
5.0000 No. 1000
fittings and accessories and first filling of transformer oil
alongwith MCCB. Protection on LV side confirming
30 Supply, drawing and laying of Mesh using GS Wire 8 SWG
(Galvanized) on the guarding for crossing as per standard or
13.0400 MT 5000
required as per location including binding as per drawing for
road / P&T/ Power Line crossing.
31 Supply & installation of metering points on 11 KV outgoing
feeder at 33/11 KV S/S.The installation work to be carried out
0.0000 0
as per drawing/design,under the supervision of concern
Assistant Engineer
32 Mounting structure (Galvanized) 0.0000 0
33 The requisite steel members will be supplied by contractor
including the hardware.Contractor shall joint/weld the
members to form the mounting structure as per 283.0000 No. 700
drawing.Necessary tools,welding ,machines,lifting devics etc.
shall be arranged by contractor.
34 Civil works 0.0000 0
35 Erection of lattices in alignment including excavation and
concreting of structure foundation including cement, sand and
grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40
283.0000 No. 4000
mm size for ratio 1:5:10 and curing for period as required (21
days). Area of concreting will be as per the drawing.

37 Installation of Metering equipments: 0.0000 0


37.1 Supply and installation 11KV CT PT Set(200/5 Amp.) 283.0000 no. 600
37.11 Supply and Installation HT TVM with accuracy 0.5 S with
283.0000 no. 80
DLMS protocol (To be provided by Nigam)
37.2 Supply and installation MIP meter boxThe meter box will be
fixed firmly with sufficient strength at a place as per drawing.
283.0000 no. 80
The test terminal block(TTB) link type shall be provided by
contractor in the meter box.
37.21 The required cables from CTPT set to meter box laid down in
50 mm GI pipe with suitable bends & nipples, shall be
provided by contractor alongwith the consumable items such
as PVC tapes, petroleum jelly etc. The cable should be PVC
multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm
& tight connections shall be made by suitable connector e.g.
0.0000
at CTPT sets by using clamps and at meter/TTB by suitable
lugs etc. The CTPT sets so installed shall be earthed by
means of the MS Flat (size 50x6 mm) by joining it with the
nearest earthing available at the sub-station. Requisite
earthing material shall be made available by the contractor.

37.3 Commissioning of Metering Equipments:Installed meters


inside the box and metering equipments duly mounted on the
mounting structure will be powered up by connecting load in
the presence of the concerned Assistant Engineer who will
arrange the necessary shut down. The completion certificate 283.0000 No. 120
shall be furnised by contractor.be filled accordingly. Since the
work involves higher A.C. voltage level, the contractor shall
take full care regarding safety norms, so as to avoid any
accidental hazards.
37.31 Supply and fixing of GO double break without EB Isolator on
existing bracket complete in all respect as required including 0.0000 0
hardware etc.
37.32 33KV (with 18 x 24 KV Post Insulator ) 800 Amp. 20.0000 No. 1300
37.33 11KV ( with 9 x 12 KV Post Insulator ) 400 Amp. 283.0000 No. 1000
37.4 Supply and fixing of horn gap sets on existing brackets in all
respect as required including hardware nut & bolt & washer 0.0000 0
etc.
37.41 33KV ( with 12 x 24 KV Post Insulator ) 1 Set=3 Nos 10.0000 No. 400
37.42 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos 283.0000 no. 200
38 Supply and Fixing of 11 KV double pole line structure set
(Galvanized) on existing poles in all respect with clamps nut
and bolts as required made from M.S. channel 100x50 X6
5.0000 No. 200
mm ISMC [9.56 kg. per mtr] ISA M.S. angle 50x50x6 and M.S.
flat 50x6 mm weight(92.969 kgs.) Approx

38.1 Supply and fixing of 33 KV Sub-station type (30 KV 10 KA


Station class) (1 set=3 No.) lightening arrestors on the
10.0000 set 300
existing brackets in all respect as required including
hardware, nut , bolt & washers etc. For O&M works.
38.2 Supply and erection of PCC Poles in all types of soil &
allignment including excavation of pit size 1.2x0.6x1.5 cum.
for 9 mtrs and 1.2x0.6x1.35 cum for 8 mtrs PCC poles in
0.0000
ground and back filling soil consolidating each deposit layer of
0.15 mtr. by watering and ramming etc. in the length.

39 PCC Ploe 9.0 mtrs long.(400 Kg.) 0.0000 0


39.1 In normal soil 75.0000 No. 750
39.2 In ordinary rock/Hard Soil which does not require drilling 5.0000 No. 900
40 In ordinary rock/Hard Soil which require drilling 0.0000 No. 1150
41 PCC Ploe 9.0 mtrs long.(200 Kg.) 0.0000 0
42 In normal soil 526.0000 No. 650
42.1 In ordinary rock/Hard Soil which does not require drilling 0.0000 No. 800
42.11 In ordinary rock/Hard Soil which require drilling 0.0000 No. 1050
42.12 PCC Ploe 8.0 mtrs long.(200 Kg.) 0.0000 0
42.13 In normal soil 130.0000 No. 600
42.2 In ordinary rock/Hard Soil which does not require drilling 10.0000 No. 750
42.21 In ordinary rock/Hard Soil which require drilling 0.0000 No. 1000
42.23 Construction of 33/11KV Transformers plate form 2.4 x 2.4x cubic
2.0 Mtrs. Including excavation in all type of soil up to the meter.
depth of 900 mm, foundation concrete in C.C. - 1 : 5 :10 for
150 mm thickness, stone masonary in cement mortar of mix.
1:8 with top of the plate form finished with 100 mm layer of 57.6000 4000
C.C. 1:2:4 alongwith 2 Nos. M.S. Rails 90 Pounds of 2.4 Mtr.
length each, alongwith cement plaster - 20 mm thick of mix
ratio 1:6, on all the exposed surfaces of the plate form -
complete in all respect.
42.24 Constn. Of 11KV/ 36 KV VCB Kiosk Plate form 3.0 x 1.5 x cubic
1.5 Mtrs. Including excavation in all type of soil up to the meter.
depth of 900 mm, foundation concrete in C.C. - 1 : 5 :10 for
150 mm thickness, brick masonary in cement mortar of mix.
1:8 with top of the plate form finished with 100 mm layer of 1977.7500 4000
C.C. 1:2:4 including fixing of foundation bolts and cement
plaster - 20 mm thick of mix ratio 1:6, on all the exposed
surfaces of the plate form - complete in all respect.

42.3 Supply and fixing of 45 KN. porcelain disc.insulators for 33


KV ( each unit consisting of 3 disc insulators & one B&S
165.0000 no. 40
Type hardware) on brackets complete including all acessories
like hardware fitting etc.
42.31 Supply and installation of Fire Extinguishers 50.0000 No. 20
42.32 Supply and fixing of ,45KN. porcelain disc.insulators for 11
KV ( each unit consisting of disc insulators & one B&S Type
3311.0000 no. 25
hardware) on brackets complete including all acessories like
hardware fitting etc.
42.33 Supply and fixing of porcelain 33KV Pin Insulator with Pins
105.0000 no. 20
on pole complete in all respect
43 Supply and fixing of porcelain 11 KV Pin Insulator with Pins
834.0000 no. 10
on pole complete in all respect
44 Supply and fixing of PG clamps Dog to Dog on over
headlines/jumpers, etc. All ferrous metal part intended for
1953.0000 no. 8
outdoor use except those made of stainless steel shall be
protected by hot dip galvanising
45 Supply and fixing of Galvanized M.S, Nuts & Bolts of assorted
9288.0000 Kg 0
sizes as per requirement
46 Supply and fixing of 11 kV Danger plate of size 200 X 250
731.0000 no. 8
mm complete in all respect
47 HT LINES 11 KV 0.0000 0
48 Conducting route survey as per approved route map and Km
1215.0000
pegging of route with section point/double pole location
49 Trimming of tree branches and preparing route appraoches per Km
1215.0000 350
for the proposed line
50 Supply and erection of PCC Poles in allignment including
excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs 200 Kg in
ground and back filling soil consolidating each deposit layer of 0.0000 0
0.15 mtr. by watering and ramming etc. in the length.

51 In normal soil 17749.0000 No. 650


52 In ordinary rock/Hard Soil which does not require drilling 1696.0000 No. 800
53 ordinary rock / CC Road which require drilling 1.0000 No. 1050
54
Supply and fixing of 11 KV double pole line structure set
(Galvanized) on existing poles in all respect with clamps as
required made from M.S. channel 100x50 X6 mm ISMC [9.56 1215.0000 Set 200
kg. per mtr] ISA M.S. angle 50x50x6 and M.S. flat 50x6 mm
[excluding cost of pole/RS Joist] weight(93 kgs.) Approx
55 Supply and Drawing of overhead steel cored aluminum
4406.8200 Km 1250
ACSR Rabbit conductor in all respect
56
Supply and Drawing of overhead steel cored aluminum ACSR
101.5800 Km 900
WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor
57 Supply and fixing of 11KV Cross Arm with Top Hamper with
clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, 17015.0000 No. 40
earth clamp 50X6 mm (Galvanized)
57.1
Supply and fixing of GI stay set (Galvanized) complete (stay
rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 0.0000 0
mm dia turn buckle) including stay clamps, strain insulator
57.2 In normal soil 10390.0000 No. 350
57.3 In ordinary rock/Hard Soil which does not require drilling 1763.0000 No. 500
58 ordinary rock / CC Road which require drilling 1.0000 No. 750
59
Supply and fixing of earthing rod set for 11 KV lines made
3646.0000 Set 180
with MS rod (Galvanised) 20 mm dia, 3 meter length along
60
Supply and drawing of 11KV T&C Type porcelain disc.
Insulators (1 Disc insulator+ 1 Hardware) complete including
7099.0000 Set 25
all accessories like hardware fitting (as per latest
specifications and drawings adopted & approved by NIGAM)
61
Supply and fixing of 11 KV Porcelain Pin insulators with pins 56693.0000 No. 10
62 Supply and fixing of LT Porcelain Pin insulators with pins 677.0000 No. 8
62.1 Supply of PG clamps (For Rabbit) made of aluminum alloy
as per IS:617-1994 . All ferrous metal part intended for
outdoor use except those made of stainless steel shall be 12570.0000 set 8
protected by hot dip galvanizing in accordance with IS 2633-
1986
62.2 Supply of PG clamps (Weasel to Weasel) made of aluminum
alloy as per IS:617-1994 . All ferrous metal part intended for
outdoor use except those made of stainless steel shall be 193.0000 No. 8
protected by hot dip galvanizing in accordance with IS 2633-
1986(latest amended)
62.3
Supply and erection of 7/10 SWG GI Stay Wire (Galvanized) 121.5400 MT 0
63 Supply and erection of 8 SWG (4mm dia) GI Wire for
196.8900 MT 4800
continuous earthing of 11 KV Line hot dip (Galvanised)
64 Supply and erection of 11 KV Danger plate of size 200 X
19446.0000 No. 8
250 mm complete in all respect
65 Supply and fixing of Galvanized M.S, Nuts & Bolts of assorted
17746.0000 Kg 0
sizes as per requirement
66 DISTRIBUTION TRANSFORMER THREE PHASE (63 KVA
0.0000 0
and 40 KVA) and SINGLE PHASE (16 KVA)
67 Supply and erection of PCC Poles in all types of soil &
allignment including excavation of pit size 1.2x0.6x1.5 cum.
for 9 mtrs and 1.2x0.6x1.35 cum PCC poles in ground and
0.0000
back filling soil consolidating each deposit layer of 0.15 mtr.
by watering and ramming etc. in the length.

68 PCC Ploe 9.0 mtrs long.(400 Kg.) 0.0000 0


69 In normal soil 255.0000 No. 750
70 In ordinary rock/Hard Soil which does not require drilling 0.0000 No. 900
71 ordinary rock / CC Road which require drilling 0.0000 No. 1150
72 PCC Ploe 9.0 mtrs long.(200 Kg.) 0.0000 0
73 In normal soil 720.0000 No. 650
74 In ordinary rock/Hard Soil which does not require drilling 0.0000 No. 800
75 ordinary rock / CC Road which require drilling 0.0000 No. 1050
75.1 Supp & erection of XLPE Insulated ACSR Rabbit (For HT) 2.5500 Km 1250
75.2 Supply and Erection of LT XLPE Cable 4CX70 sq mm 9.0000 Km 10000
75.3 Supply & Installation of 11 /0.4 KV 63 KVA Al wound,
conventional outdoor type distribution transformers with all
fittings and accessories and first filling of transformer oil 196.0000 no. 1700
alongwith MCCB. Protection on LV side confirming to
technical specification
76 Supply & Installation of 11 /0.4 KV 40 KVA Al wound,
conventional outdoor type distribution transformers with all
fittings and accessories and first filling of transformer oil 164.0000 no. 1350
alongwith MCCB. Protection on LV side confirming to
technical specification
76.1
Supply & Installation of 6.35KV/240 V 16 KVA copper wound,
conventional outdoor type distribution transformers with all
255.0000 No. 650
fittings and accessories and first filling of transformer oil
alongwith MCCB. Protection on LV side confirming
76.2 Supply and erection of GS Stay Wire of Size 7/10 SWG
(Galvanized) tightened through 11 KV Strain insulator on
14.1885 MT 0
existing stay set & pole etc., as required complete in all
respect.
76.3 Supply and erection M.S. Flat 50 X 6 mm for mounting single
6.0180 MT 4000
phase transformer on poles.
77
Supply, erection and foundation of LT Supply Pillar Box of
200 Amp. capacity as per specification of Nigam . Each Base
should be grouted including excavation , bricks , sand,
cement masonary of size 4"X3"X10" and 3' in ground & 1.5'
above road level with muffing to support & mounting the Pillar
. The masonary will have 4"X4" opening 2" below ground level
two in rear side & one each in the remaining sides to facilitate
entry & exit of incoming & outgoing cables inside the pillar box 360.0000 no. 3200
shall be connected to DP Earth with 7/10 SWG Stay Wire &
Lugs duly bolted on the place meant for XLPE cables inside
the box shall be fixed with clamps making connections /
jumpers by Aluminium lugs / PG Clamps of required size on
LT Distribution mains on one end & with MCB / with isolator
on the other end. Lugs should be crimped with crimping tools
including cost of lugs, etc.
78 Supply & Drawing of overhead steel cored aluminium ACSR
WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor 8.6400 km 900
specification
79 Supply and fixing of 11KV ( with 9 x 12 KV Post Insulator )
400 Amp. GO double break without EB Isolator on existing
360.0000 no. 1000
bracket complete in all respect as required including hardware
etc.
80
Supply and Fixing of 11/0.4 KV SubStation structure set on
existing poles in all respect with clamps made from M.S.
channel 100x50 X6 mm and 75x40 mm, M.S. angle 50x50x6 360.0000 no. 300
and M.S. flat 50x6 mm and 50x8 mm weight(147.3 kgs.)
Approx (All galvanized as per relevant IS)
81 Supply and fixing of horn gap sets on existing brackets in all
respect as required including hardware nut & bolt & washer
255.0000 Set 125
etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 Nos

82 Supply and fixing of 6.35/0.24 KV substation structure for 16


KVA complete (galvanized as per IS) complete in all respect
made of MS Channel, MS angle and MS flat etc. including nut
255.0000 Set 80
,bolt,flat and spring washer (as per latest specification and
drawing adopted & approved by NIGAM) (36.054 Kg. + 2 Kg.
approx.)
83
Supply and fixing of earthing rod sets for S/S made with MS
Rod (Galvanized ) 20 mm dia, 3 meter length as per latest 1845.0000 set 180
specification and drawing adopted & approved by NIGAM.
84 Supply and fixing of 11 KV 100 Amp. Drop out cum isolator
with 5.0 Amp. fuse & 12 KV post insulators including nut, bolt
360.0000 no. 200
& washers as required as per technical specifications,
approved drawings and scope of work.
85
Supply and fixing of GI stay set complete (stay rod 20 mm
dia,20 X 2400 mm long,anchor plate ) (Galvanized) including
0.0000 0
stay clamps, strain insulator, as per latest specification and
drawings adopted & approved by the NIGAM.
86 In normal soil 510.0000 No. 350
87 In ordinary rock/Hard Soil which does not require blasting 0.0000 No. 500
88 ordinary rock / CC Road 0.0000 No. 750
89 Supply and fixing of GI stay set complete (stay rod 16 mm
dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn
buckle) (Galvanized) including stay clamps, strain insulator 0.0000 0
as per latest specification and drawings adopted & approved
by the NIGAM.
90 In normal soil 1080.0000 No. 350
91 In ordinary rock/Hard Soil which does not require drilling 360.0000 No. 500
92 ordinary rock / CC Road which require drilling 0.0000 No. 750
92.1
Supply and fixing of 11KV T&C Type porcelain disc.
Insulators (1 Disc insulator+ 1 Hardware) complete including
255.0000 No. 10
all accessories like hardware fitting (as per latest
specifications and drawings adopted & approved by NIGAM)
92.2
Supply and fixing of 11 KV Porcelain Pin insulators with pins 1335.0000 No. 10
92.3 Supply and fixing of Danger plate of size 200 X 250 mm
975.0000 No. 8
complete in all respect
93 Supply of PG clamps (For Rabbit) made of aluminum alloy as
per IS:617-1994. All ferrous metal part intended for outdoor
use except those made of stainless steel shall be protected
1020.0000 No. 8
by hot dip galvanizing in accordance with IS 2633-1986(latest
amended) com plete in all respect as required for ACSR
conductor,
93.1
Supply and fixing of PG clamps (Weasel to Weasel) made of
aluminum alloy as per IS:617-1994 etc. All ferrous metal part
intended for outdoor use except those made of stainless steel
1080.0000 no. 8
shall be protected by hot dip galvanizing in accordance with
IS 2633-1986(latest amended) com plete in all respect as
required for ACSR conductor,
93.2 Supply and fixing of Galvanized M.S, Nuts & Bolts of assorted
0.0000 Kg 0
sizes as per requirement
93.3 THREE PHASE AND SINGLE PHASE LT LINES 0.0000 0
94 Supply and erection of 8.0 Mtr.long (200 Kg.) PCC Poles in
all types of soil & allignment including excavation of pit size
1.2x0.6x1.35 cum for 8 mtrs PCC poles in ground and back 0.0000
filling soil consolidating each deposit layer of 0.15 mtr. by
watering and ramming etc. in the length.
95 In normal soil 7237.8058 No. 600
96 In ordinary rock/Hard Soil which does not require drilling 804.6796 No. 750
97 Hard Rock/ CC Road which require drilling 0.0000 No. 1000
98 Supply and erection of GS Stay Wire of Size 7/10 SWG
tightened through 11 KV Strain insulator on existing stay set 0.0000 MT 0
& pole etc., as required complete in all respect.
99 Supply and Laying of 3Cx25+1CX25 Sq. mm overhead
170.7700 Km 2800
ABC(Aerial bunched cable) with Bare Messenger
100 Supply and Laying of overhead ABC(Aerial bunched cable)
72.8700 KM 2200
1C X25 +1CX25 sqmm with Bare Messenger
101
Supply and fixing of GI stay set (Galvanized) complete (stay
rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 0.0000 0
mm dia turn buckle) including stay clamps, strain insulator
101.1 In normal soil 473.0874 Set 350
101.2 In ordinary rock/Hard Soil which does not require drilling 236.5437 Set 500
101.3 ordinary rock / CC Road which require drilling 0.0000 Set 750
102 Supply and fixing of Dead end (anchor) clamps for insulated
or bare messenger +one pole bracket + one Pole Bracket +
1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per 473.0874 Set 40
NFC Standard suitable for AB Cable Complete in all respect
(galvanized as per IS)
103 Supply and fixing of Suspension (anchor) clamps for
insulated or bare messenger +one pole bracket + one Pole
Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS 7096.3107 No. 40
Buckles as per NFC Standard suitable for AB Cable
Complete in all respect (galvanized as per IS)
104
Supply and fixing of LT insulation piercing connectors NFC
7096.3107 No. 16
Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2)
105 Supply and fixing of LT insulation piercing connectors NFC
473.0874 No. 16
type B ( main to main) (size 16-50 mm2)
105.1 BPL CONNECTION WITH SERVICE LINES 0.0000 0
105.2
Supply and fixing of ISI mark 2CX4 Sq.mm. 1100 Volt heavy
duty armoured PVC XLPE Cable of Aluminium conductor 18.4000 Km 1000
conforming to IS:7098 (Part-I) (latest amended).
105.3 Supply and Fixing of 9 watts , 250 V LED Lamp 736.0000 No. 2
106 Supply and fixing of Thermosetting Plastics e.g. Glass Fibre
reinforced polyster (Sheet Moulding Compound) Board with 736.0000 No. 20
all accessories
107 Supply and Fixing of (galvanized as per IS) 16 mm Dia, 2
Meter long MS type earthing . The other end will be
736.0000 No. 9
connected to the earth terminal provided at meter board.

108 Fixing of single phase rating 5-30 A, A.C. static static energy
meter having LCD display with moulded box (complete unit)
736.0000 No. 125
with 4 Nos. anchor fastners of rust proof type of size 6X50
mm. (To be provided by the Nigam)
109 Supply and fixing of single piano type ISI marked 250V/5A
switch with copper contact on existing Board including making 736.0000 No. 3
connections etc. as required.
110 Supply and fixing of 250V/5A ISI marked holder including
736.0000 No. 3
making connections etc. as required.
111 Supply and fixing of 1.5 sqmm copper multistrands PVC
1.4720 Km 0
insulated ISI marked cable for internal wiring.
112 Supply and fixing of 10 Amp. 240 Volts ISI mark MCB. 736.0000 No. 8
113 Supply and fixing of 1.33 m long, 50x50x6 mm size, M.S.
angle(galvanized as per IS) for support of service line at
184.0000 set 30
consumer end including one set (2Nos.) with flat and spring
washers(galvanized as per IS).
114 Supply and fixing of Galvanized M.S, Nuts & Bolts of assorted
0.1840 Kg 0
sizes as per requirement
115
Supply and fixing of 10 SWG (5mm dia) GI Wire for
continuous earthing hot dip (Galvanised) as per technical 0.1470 MT 25000
specification, approved drawings and scope of work.
116 INSTALLATION OF NEW AND REPLACEMENT OF
DEFECTIVE THREE AND SINGLE PHASE METERS, AND 0.0000 0
DT METERING
117 Fixing of single phase rating 5-30 A, A.C. static static energy
meter having LCD display with moulded box (complete unit)
46016.0000 No. 125
with 4 Nos. anchor fastners of rust proof type of size 6X50
mm. (To be provided by the Nigam)
118 Fixing of erection of Three Phase Static Energy Meter 10-60
A with LCD Display with metr Box (To be provided by the 1556.0000 No. 150
Nigam)
119 Supply & installation of metering points on 11 KV outgoing
feeder at 33/11 KV S/S.The installation work to be carried out
0.0000 0
as per drawing/design,under the supervision of concern
Assistant Engineer
120 Mounting structure (Galvanized) 0.0000 0
121 The requisite steel members will be supplied by contractor
including the hardware.Contractor shall joint/weld the
members to form the mounting structure as per 364.0000 no. 700
drawing.Necessary tools,welding ,machines,lifting devics etc.
shall be arranged by contractor.
122 Civil works 0.0000 0
123 Erection of lattices in alignment including excavation and
concreting of structure foundation including cement, sand and
grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40
364.0000 no. 4000
mm size for ratio 1:5:10 and curing for period as required (21
days). Area of concreting will be as per the drawing.

124 Installation of Metering equipments: 0.0000 0


125 Supply and installation 11KV CT PT Set(200/5 Amp.) 364.0000 no. 600
127 Installation HT TVM with accuracy 0.5 S with DLMS
364.0000 no. 80
protocol(To be provided by the Nigam)
127.1 Supply and installation MIP meter boxThe meter box will be
fixed firmly with sufficient strength at a place as per drawing.
364.0000 no. 80
The test terminal block(TTB) link type shall be provided by
contractor in the meter box.
127.11 The required cables from CTPT set to meter box laid down in
50 mm GI pipe with suitable bends & nipples, shall be
provided by contractor alongwith the consumable items such
as PVC tapes, petroleum jelly etc. The cable should be PVC
multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm
& tight connections shall be made by suitable connector e.g.
0.0000
at CTPT sets by using clamps and at meter/TTB by suitable
lugs etc. The CTPT sets so installed shall be earthed by
means of the MS Flat (size 50x6 mm) by joining it with the
nearest earthing available at the sub-station. Requisite
earthing material shall be made available by the contractor.

127.2 Commissioning of Metering Equipments:Installed meters


inside the box and metering equipments duly mounted on the
mounting structure will be powered up by connecting load in
the presence of the concerned Assistant Engineer who will
arrange the necessary shut down. The completion certificate 364.0000 no. 120
shall be furnised by contractor.be filled accordingly. Since the
work involves higher A.C. voltage level, the contractor shall
take full care regarding safety norms, so as to avoid any
accidental hazards.
127.21 Supply , Laying, Testing Termination of control Cable of size
4 X 4 SQ.MM. 1100 Volts PVC Insulated including supply and
installation of ferrules to design various cores of control 3.6400 Km. 9000
cables by terminal no. of identification including utilisation of
cable gland.
127.3 Supply of ISI mark 2CX4 Sq.mm. 1100 Volt heavy duty
armoured PVC XLPE Cable of Aluminium conductor 690.2400 Km. 1000
conforming to IS:7098 (Part-I) (latest amended).
127.31 Supply and laying of LT XLPE Cable (Armoured) 4C X16
23.3400 Km. 2000
Sq.mm
127.32 RETREIVAL OF MATERIAL 0.0000 0
127.33 Removal of 11kv Line O/H to O/H 0.0000
127.34 AAC/AAAC/ACSR Conductor 812.0000 Kms 1000
127.35 ENERGY METERS: 0.0000 0
128 1ph Static Energy Meter 10-40A with Moulded Box 25171.0000 Nos. 25
129 3ph Energy Meter 10-40A with Moulded Box 564.0000 Nos. 25
130 FOR SINGLE PH - 2CX4 SQ.MM 629.0000 Km 1000
131 FOR THREE PH - 4CX6 SQ.MM 14.0000 Km 2000
Total in Figures

Note :
1 Rates are inclusive of freight till 40 km radius from project stores
2 Rates are inclusive of all required labour compliances - PF/ ESIC etc as per Voltas
Compliance requirements. If Contractor is unable to do compliance, Voltas shall do
3 Rates are exclusive of Service Tax
4 Rates are exclusive of Hundi Charges on Total Invoice Value
5 Subcontractor need to ensure safety procedures are followed during installation of
materials as per Voltas Safety Policy. For every safety violation noted Rs. 500/- shall be