You are on page 1of 52

SCHEDULE OF QUANT

Sl. No. Item Descripti

Supply, Installation, testing and commissioning of Lighti


erection, unpacking, assembly (including installation an
1 foundations or fixing to the wall or steel structures, alig
including all labor and materials complete as per specifi
engineering & safety practices.

1.1 250A Busbar Chamber with Cu strip for 4 No.s of Outgoin

1.2 160A Busbar Chamber with Cu strip for 6 No.s of Outgoin

1.3 AC/Power Distribution Board; I/C 125A TPN MCB , O/G- 2


SCHEDULE OF QUANT

Sl. No. Item Descripti

1.4 AC/Power Distribution Board; I/C 63A TPN MCB , O/G- 20

1.5 Lighting Distribution Board; I/C 100A TPN MCB , O/G- 16

1.6 Computer Socket Distribution Board; I/C 63A TPN MCB ,

2 Internal Lighting of Fire Station Building

Supply, installation, connecting, testing and commissioni


2.1 supports etc., including fixing of cable gland, lugs, includ
neccessories like mounting, fixing bolt, etc., as per appro
SCHEDULE OF QUANT

Sl. No. Item Descripti

Supply, installation, testing and commisioning of followin


2.2 all labour and material as per approved drawing specifica
engineering and safety practices

Supply, installation , testing and commissioning of 1x28W


fixture including all necessary supports etc,.Including fixi
2.3 and material, and necessaries like mounting, fixing bolts
specifications

Supply, installation , testing and commissioning of 2x28W


Fixture including all necessary supports etc,.Including fix
2.4
and material, and necessaries like mounting, fixing bolts
specifications
SCHEDULE OF QUANT

Sl. No. Item Descripti

Supply, installation , testing and commissioning of 200m


2.5 including all necessary supports etc,.Including fixing of ca
material, and necessaries like mounting, fixing bolts, etc.

Supply, installation , testing and commissioning of Bajaj 2


2.6 necessary supports etc,.Including fixing of cable glands, l
necessaries like mounting, fixing bolts, etc., as per appro

2.7 Supply Installation and tesing and Commissioning of 14 W


SCHEDULE OF QUANT

Sl. No. Item Descripti

3 Supply And Install Conduit type wirinng

Supply, installation, testing and commmisioning of ligh


wires following size as per specification approved draw
standard practices. Including supply of Modular Switch

3.1 10 sq. mm + 2.5. sqmm earthing stranded wire through


SCHEDULE OF QUANT

Sl. No. Item Descripti

3.2 4 sq. mm + 2.5. sqmm earthing stranded wire through 2

3.3 2.5 sq. mm + 1.5. sqmm earthing stranded wire through

3.4 2.5 sq. mm + 1.5 sqmm earthing stranded wire through


SCHEDULE OF QUANT

Sl. No. Item Descripti

3.5 1.5 sq. mm + 1.0. sqmm earthing stranded wire through

3.6 1.5 sq. mm + 1.0. sqmm earthing stranded wire through


SCHEDULE OF QUANT

Sl. No. Item Descripti

Supply installation, testing and commmisioning of type


and wires following size including supply of modular Sw
4
neccessory hardware, accessories as per specification a
engineering standard practices.

4.1 6 Sq mm Stranded wire through 25mm Conduit pipe for

4.2 2.5 Sq mm Stranded wire through 25mm Conduit pipe fo


SCHEDULE OF QUANT

Sl. No. Item Descripti

Computer Modular Sokect Arrangment; Supply, Installa


Computer Moudlar Socket Cluster using Fr-PVC Conduit
5 supply of Modular switch socket Cluster Boardwith 3 N
and Indicating lamp, including all necessary hardware, a
drawings and complying with all Engineering Standard

5.1 2.5 Sq mm Stranded wire through 25mm Conduit pipe fo


SCHEDULE OF QUANT

Sl. No. Item Descripti

6 Supply of Following of Sizes of cables as per specificatio

6.1 1100V, 4Cx 70 Sq. mm, Cu PVC Armoured cable

6.2 1100V, 3.5Cx 35 Sq. mm, Cu PVC Armoured cable


SCHEDULE OF QUANT

Sl. No. Item Descripti

Installation of Cables Horizontal and vertical laying of ca


the following overall diamteres in ready trays/ trenches
pipes including supply and fixing of aluminium strip num
7 and saddle bars MS Support etc. Clamping of 1C cables
cables by non magnetic materials., unpacking and inclu
per approved drawings specifications complying with a
practices.including all required Double compression Gla

LT CABLE LAYING(Upton +7Mtr elevation)


SCHEDULE OF QUANT

Sl. No. Item Descripti

7.1 above 16mm2 to 70mm2

7.2 above 70mm2

8 CONNECTIONS

Supply, Installation, testing and Commisioning of Conne


earth strip with following sizes including the supply of
and necessary hard ware for connection, all labor and m
standard engineering & safety practices. .
SCHEDULE OF QUANT

Sl. No. Item Descripti

8.1 16mm2 Single Core Aluminium Cable, PVC insulated


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

missioning of Lighting / Power Distribution board including


uding installation and wiring of loose parts, installation on
steel structures, aligning, leveling, grouting, testing etc.
mplete as per specifications complying with all standard

or 4 No.s of Outgoing holding 50Sq.mm Cu Cable

or 6 No.s of Outgoing holding 25Sq.mm Cu Cable

5A TPN MCB , O/G- 20A DP MCB- 6Nos.


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

A TPN MCB , O/G- 20A DP MCB- 4Nos.

TPN MCB , O/G- 16A SP MCB- 16Nos.

I/C 63A TPN MCB , O/G- 16A SP MCB- 12Nos.

ding

ng and commissioning of fans including supply of all neccessory


e gland, lugs, including all labour and materials, and
lt, etc., as per approved drawings,specification
ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

misioning of following rating of split AC Capcity of 2 Ton including


ed drawing specification and complying with all standard

missioning of 1x28W recess mounted decorative T5 Lighting


rts etc,.Including fixing of cable glands, lugs, including all labour
ounting, fixing bolts, etc., as per approved drawings &

missioning of 2x28W recess mounted decorative T5Lighitng


rts etc,.Including fixing of cable glands, lugs, including all labour
ounting, fixing bolts, etc., as per approved drawings &
ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

missioning of 200mm (8") Sweep type PVC body Exhaust fan


Including fixing of cable glands, lugs, including all labour and
ting, fixing bolts, etc., as per approved drawings & specifications

missioning of Bajaj 218 LHDLighting fixture including all


ng of cable glands, lugs, including all labour and material, and
s, etc., as per approved drawings & specifications

mmissioning of 14 W CFL light f including all necessory support


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

nng

mmisioning of light point wiring using FR-PVC conduit and


tion approved drawings and complying with all engineering
of Modular Switch and Socket with Boards

anded wire through 25 mm conduit for primary point wiring


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

nded wire through 25 mm conduit for primary point wiring

anded wire through 25 mm conduit for primary point wiring

anded wire through 25 mm conduit for Secondry point wiring


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

anded wire through 25 mm conduit for primary point wiring

anded wire through 25 mm conduit for Secondry point wiring


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

mmisioning of type socket point wiring using FR-PVC conduit


upply of modular Switch sockets withSwitch Board including all
s per specification approved drawings and complying with all

m Conduit pipe for Primary point wiring

mm Conduit pipe for Primary point wiring


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

ent; Supply, Installation, testing and commissioning of


sing Fr-PVC Conduit and wires for following size including
ster Boardwith 3 Nos. of Socket Outlet, with a Modular switch
cessary hardware, accessories as per specification approved
gineering Standard Practices.

mm Conduit pipe for Primary point wiring


ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

s as per specification and approved drawings

ured cable

moured cable
ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

vertical laying of cables of different voltage grade and types of


ady trays/ trenches/ supported on structure/pull through
aluminium strip number tags, supply and fixing of GI saddles
mping of 1C cables by non magnetic materials. Clamping of 1C
unpacking and including all labor and materials complete as
s complying with all standard engineering & safety
ble compression Glands and Lugs for termination

ation)
ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

mmisioning of Connection from individual equipment to the


uding the supply of lugs, conductors connecting to the GI strip
tion, all labor and materials complete complying with all
tices. .
ULE OF QUANTITIES FOR INTERNAL LIGHTING ELECTRIC

Item Description

e, PVC insulated
ING ELECTRICAL WORKS

Unit Qty. Remarks

Nos. 1

Nos. 1

Nos. 1
ING ELECTRICAL WORKS

Unit Qty. Remarks

Nos. 2

Nos. 2

Nos. 1

Nos. 27
ING ELECTRICAL WORKS

Unit Qty. Remarks

Nos. 8

Nos. 25

Nos. 10
ING ELECTRICAL WORKS

Unit Qty. Remarks

Nos. 4

Nos. 28

Nos. 40
ING ELECTRICAL WORKS

Unit Qty. Remarks

Wiring should be 10 sq.mm


Nos. 2 Stranded wire for R, Y & B and
2.5Sq.mm for Earthing
ING ELECTRICAL WORKS

Unit Qty. Remarks

Wiring should be 4 sq.mm Stranded


Nos. 2 wire for Ph & neutral and 2.5Sq.mm
for Earthing

Wiring should be 2.5 sq.mm


Nos. 25 Stranded wire for Ph & neutral and
1.5Sq.mm for Earthing

Wiring should be 2.5 sq.mm


Nos. 20 Stranded wire for Ph & neutral and
1.5Sq.mm for Earthing
ING ELECTRICAL WORKS

Unit Qty. Remarks

Wiring should be 1.5 sq.mm


Nos. 100 Stranded wire for Ph & neutral and
1.0Sq.mm for Earthing

Wiring should be 1.5 sq.mm


Nos. 45 Stranded wire for Ph & neutral and
1.0Sq.mm for Earthing
ING ELECTRICAL WORKS

Unit Qty. Remarks

Wiring should be 6 sq.mm Stranded


Nos. 15 wire for Ph & neutral and 2.5Sq.mm
for Earthing

Wiring should be 2.5 sq.mm


Nos. 20 Stranded wire for Ph & neutral and
1.5Sq.mm for Earthing
ING ELECTRICAL WORKS

Unit Qty. Remarks

Wiring should be 2.5 sq.mm


Nos. 20 Stranded wire for Ph & neutral and
1.5Sq.mm for Earthing
ING ELECTRICAL WORKS

Unit Qty. Remarks

Mtrs. 35

Mtrs. 100
ING ELECTRICAL WORKS

Unit Qty. Remarks


ING ELECTRICAL WORKS

Unit Qty. Remarks

Mtrs. 135

Mtrs. 80
ING ELECTRICAL WORKS

Unit Qty. Remarks

Mtrs. 125
Remarks
Remarks
Remarks
Remarks
Remarks

should be 10 sq.mm
wire for R, Y & B and
q.mm for Earthing
Remarks

uld be 4 sq.mm Stranded


& neutral and 2.5Sq.mm
for Earthing

should be 2.5 sq.mm


ire for Ph & neutral and
q.mm for Earthing

should be 2.5 sq.mm


ire for Ph & neutral and
q.mm for Earthing
Remarks

should be 1.5 sq.mm


ire for Ph & neutral and
q.mm for Earthing

should be 1.5 sq.mm


ire for Ph & neutral and
q.mm for Earthing
Remarks

uld be 6 sq.mm Stranded


& neutral and 2.5Sq.mm
for Earthing

should be 2.5 sq.mm


ire for Ph & neutral and
q.mm for Earthing
Remarks

should be 2.5 sq.mm


ire for Ph & neutral and
q.mm for Earthing
Remarks
Remarks