Cu/PVC (NYA) Cu/PVC-f (NYAF) Cu/PVC-f (NYAF) Cu/PVC-f (NYAF) Cu/PVC/PVC (NYM) Cu/PVC/PVC (NYY)
450/750 V 300/500 V 450/750 V 0.6/1 kV 300/500 V 0.6/1 kV
16 17 18 20 22 24
Cu/PVC/PVC-f (NYMHY) Cu/PVC/PVC-f (NYMHY) Cu/PVC/PVC-f (NYYHY) Cu/MICA/LSHF/LSHF Screen Cable Telephone Wire
300/300 V 300/500 V 0.6/1 kV Fire Resistant Cable
25 26 27 28 29 30
Speaker Wire Monster Cu/PVC/PVC-f (NYZ) Microphone Cable Coaxial Cable Our Projects List
300/300 V
2 3
INTRODUCTION
In the spirit of our tagline Finest Cables for Your World With our headquarter located in Jakarta and Since our establishment in 1978, PT. Although cable is an interbusiness product that most users
– We believe that both your home and workplace are the manufacturing facilities in Gunung Putri, Bogor – Federal Mardhika Citramandiri has taken are not aware of its actual use, it is very close to our daily
two most important worlds of your life. We are committed Indonesia; we’re focused in manufacturing for building pride to be an innovative company with high lives such as battery recharging, empower the computer
and deliver music through sound system.
for providing the best quality cable to accompany your or home wiring, low-voltage electric applications, adaptability, flexibility and responsiveness
everyday activities and protect you and your family from telecommunication, electronics, data and signal cables – to produce high quality prevision cables
So it’s important to have quality cables that will affect your
the danger of electricity failure. – providing a wide range of complete & reliable cable that meet the demands of World-Class safety and life’s performance. Gradually, the public will
solutions for domestic premises, office buildings, industries and exclusive customers. be more aware of the role of quality cables, especially in
By using the finest quality material and through the industries and high-technology customized cables such Indonesia - a rapidly growing country.
process of strict quality control, Federal Kabel provide the as satellite and cinema audio system cables.
best quality cable consistently with the lowest electrical
resistance. Therefore, our cables are beneficial to lower the
use of electrical power and reduce your electricity bills.
4 5
Federal Kabel Catalogue
FINEST
QUALITY
Apindo Certificate
Association of Indonesian Entrepreneurs
TUV Certificate
ISO 9001 : 2008
6 7
We guarantee that our cable is
made of 99.99% pure copper
conductor with conductor sized
Manufacturing precisely as printed on the cable.
Processes
Ensuring topnotch quality, Federal Kabel goes through rigorous process in achieving premium
standard from Drawing, Annealing, Tinning, Bunching, Braiding, Tapping, Extrusion and
Laboratory testing :
Federal Quality
Management System
This is the key factor that defines Federal Kabel as a
long-lasting brand which is consistently producing Throughout the longer life span of
world-class reliable products that our customers your cable,
can fully trusts.
Supported by higher quality insulation
material and amazing tolerance to high
Quality Assurance temperature, Federal Kabel gives you :
With comprehensive quality manual that covers standard and testing procedures, we apply stringent quality
control not only on incoming material and outgoing finished goods, but also on each step of the manufacturing
processes. Comfort with higher safety standard
8
Federal Kabel Catalogue Federal Kabel Catalogue
SPECIFICATION SPECIFICATION
SNI 04-6629.3 SNI 04-6629.3
60227 IEC 01 60227 IEC 06
APPLICATION APPLICATION
Single core insulated conductor, without sheath, for Single core insulated conductor, without sheath, for
permanent installation in conduit or exposed wiring in dry general purposes. Suitable for fixed protected installation, or
location and in switch board and control panel. on, lighting or control gear for rated voltages up to 300/500 V.
Installation in surface mounted or embedded conduits, or
similar closed systems.
1- Conductor : Annealed copper wire Test Voltage : 2.5 kV / 5 Min 1- Conductor : Annealed bunched copper wire Test Voltage : 2.5 kV / 5 Min
2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C 2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C
Flame Retardant : IEC 60332-1 Flame Retardant : IEC 60332-1
Min. Tensile Strength : 12.75 N/mm2 Min. Tensile Strength : 10.25 N/mm2
Dimension and Weight Electrical Properties Dimension and Weight Electrical Properties
Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short Circuit Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short Circuit
Section Diameter Diameter Weight Carrying Current Section Diameter Diameter Weight Carrying Current
Area (100m) Capacity Area (100m) Capacity
Conductor Insulation at 30°C 1 Sec Conductor Insulation at 30°C 1 Sec
1.5 1.40 0.70 2.80 2.10 11.90 50 24 0.17 0.5 16 x 0.20 0.64 2.20 0.95 37.10 65 6 0.06
2.5 1.80 0.80 3.40 3.20 7.14 50 32 0.29 0.75 24 x 0.20 0.66 2.45 1.25 24.70 58 12 0.09
4 2.26 0.80 3.85 4.70 4.47 50 43 0.46 1 32 x 0.20 0.67 2.65 1.55 18.50 53 19 0.12
10 11
Federal Kabel Catalogue Federal Kabel Catalogue
SPECIFICATION SPECIFICATION
SNI 04-6629.3 SNI IEC 60502-1
60227 IEC 02
APPLICATION APPLICATION
Single core insulated conductor, without sheath, for Single core insulated conductor, without sheath, for
general purposes. Suitable for fixed protected installation, or general purposes. Suitable for fixed protected installation, or
on, lighting or control gear for rated voltages up to 450/750 V. on, lighting or control gear for rated voltages up to 0.6/1 kV.
Installation in surface mounted or embedded conduits, or Installation in surface mounted or embedded conduits, or
similar closed systems. similar closed systems.
1- Conductor : Annealed bunched copper wire Test Voltage : 2.5 kV / 5 Min 1- Conductor : Annealed bunched copper wire Test Voltage : 3.5 kV / 5 Min
2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C 2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 105°C
Flame Retardant : IEC 60332-1 Flame Retardant : IEC 60332-1
Min. Tensile Strength : 10.25 N/mm2 Min. Tensile Strength : 10.25 N/mm2
Dimension and Weight Electrical Properties Dimension and Weight Electrical Properties
Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short Circuit Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short Circuit
Section Diameter Diameter Weight Carrying Current Section Diameter Diameter Weight Carrying Current
Area (100m) Capacity Area (100m) Capacity
Conductor Insulation at 30°C 1 Sec Conductor Insulation 1 Sec
at 30°C
mm 2
N x mm mm mm Kg Max. Min. A kA mm2 N x mm mm mm Kg Max. Min. A kA
Ω/km M.Ω.km Ω/km M.Ω.km
1.5 30 x 0.25 0.78 3.15 2.20 12.40 50 24 0.17 1.5 30 x 0.25 0.85 3.30 2.30 12.10 50 24 0.17
2.5 50 x 0.25 0.85 3.75 3.35 7.20 46 32 0.29 2.5 50 x 0.25 0.90 3.85 3.45 7.41 46 32 0.29
4 57 x 0.30 0.90 4.43 5.15 4.40 40 42 0.46 4 57 x 0.30 1.08 4.80 5.50 4.61 40 42 0.46
6 85 x 0.30 1.15 5.50 7.80 3.00 36 53 0.69 6 85 x 0.30 1.15 5.50 7.75 3.08 36 53 0.69
10 80 x 0.40 1.20 6.53 12.00 1.88 32 72 1.16 10 80 x 0.40 1.20 6.53 12.05 1.83 32 72 1.16
16 7 x 18/0.40 1.20 8.28 18.85 1.15 23 97 1.84 16 7 x 18/0.40 1.20 8.28 18.85 1.15 23 97 1.84
25 7 x 28/0.40 1.28 9.90 28.50 0.70 23 128 2.88 25 7 x 28/0.40 1.35 10.05 28.70 0.73 23 128 2.88
35 7 x 40/0.40 1.32 11.40 39.50 0.55 20 156 4.03 35 7 x 40/0.40 1.35 11.47 39.50 0.52 20 156 4.03
50 7 x 57/0.40 1.47 13.40 55.30 0.38 20 195 5.75 50 7 x 57/0.40 1.55 13.57 55.90 0.38 20 195 5.75
70 7 x 80/0.40 1.62 15.04 75.50 0.27 20 243 8.05 70 7 x 80/0.40 1.62 15.04 75.50 0.27 20 243 8.05
12 13
Federal Kabel Catalogue Federal Kabel Catalogue
SPECIFICATION SPECIFICATION
SNI 04-6629.4 SNI IEC 60502-1
60227 IEC 10
APPLICATION APPLICATION
Multicore insulated conductor, with sheath, for general Power cable indoors and outdoors or burried in the ground, for
purposes. Suitable for fixed protected installation in outdoor power stations, industry and switchgear as well as for urban
or indoor applications. Standard cable for plaster, brickwork & supply networks, where mechanical damages are not to be
immovable concrete. expected.
1- Conductor : Annealed copper wire Test Voltage : 2 kV / 5 Min 1- Conductor : Annealed copper wire Test Voltage : 3.5 kV / 5 Min
2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C 2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 105°C
3- Outer Sheath : PVC (Polyvinyl Chloride) Flame Retardant : IEC 60332-1 3- Outer Sheath : PVC (Polyvinyl Chloride) Flame Retardant : IEC 60332-1
Min. Tensile Strength : 12.75 N/mm2 Min. Tensile Strength : 12.75 N/mm2
Dimension and Weight Electrical Properties Dimension and Weight Electrical Properties
No. of Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short No. of Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short
Cores Section Diameter Diameter Weight Carrying Circuit Cores Section Diameter Diameter Weight Carrying Circuit
Area (100m) Capacity Current Area (100m) Capacity Current
at 30°C at 30°C
Insulation Sheath Conductor Insulation 1 Sec Insulation Sheath Conductor Insulation 1 Sec
1.5 1.40 0.70 1.40 9.20 12.20 12.10 50 19 0.17 1.5 1.40 0.80 1.80 11.00 17.20 12.10 62 21 0.17
2 2.5 1.80 0.80 1.40 10.40 17.10 7.28 50 25 0.29 2 2.5 1.80 0.90 1.80 12.40 22.70 7.28 57 29 0.29
4 2.26 0.85 1.40 11.52 23.30 4.56 50 34 0.46 4 2.26 1.00 1.80 14.12 32.10 4.56 52 38 0.46
1.5 1.40 0.70 1.40 9.65 14.50 12.10 50 19 0.17 1.5 1.40 0.80 1.80 11.86 20.20 12.10 62 18 0.17
3 2.5 1.80 0.80 1.40 10.90 20.00 7.28 50 25 0.29 3 2.5 1.80 0.90 1.80 12.95 26.10 7.28 57 25 0.29
4 2.26 0.85 1.40 12.15 26.70 4.56 50 34 0.46 4 2.26 1.00 1.80 14.80 35.80 4.56 52 34 0.46
1.5 1.40 0.70 1.40 10.35 17.10 12.10 50 19 0.17 1.5 1.40 0.80 1.80 12.65 23.40 12.10 62 18 0.17
4 2.5 1.80 0.80 1.40 11.80 24.00 7.28 50 25 0.29 4 2.5 1.80 0.90 1.80 14.10 31.00 7.28 57 25 0.29
4 2.26 0.85 1.40 13.15 34.15 4.56 50 34 0.46 4 2.26 1.00 1.80 15.88 42.00 4.56 52 34 0.46
14 15
Federal Kabel Catalogue Federal Kabel Catalogue
Cu/PVC-f (NYAF)
Cu/PVC/PVC-f (NYMHY) 300/300 V Cu/PVC/PVC-f (NYMHY) 300/500 V
SPECIFICATION SPECIFICATION
SNI 04-6629.5 SNI 04-6629.5
60227 IEC 52 60227 IEC 53
APPLICATION APPLICATION
For connecting electrical appliances, devices and instruments Permanent installation in conduit under plaster or useful for
to the power supply network. Can be used for cooking and use in dry or damp locations for medium duties in domestic
heating appliances provided that the cable does not come in premises, kitchens, offices, washing machines, refrigerators,
contact with the hot parts. etc. Can be used for cooking and heating appliances provided
that the cable does not come in contact with the hot parts.
1- Conductor : Annealed bunched copper wire Test Voltage : 2 kV / 5 Min 1- Conductor : Annealed bunched copper wire Test Voltage : 2 kV / 5 Min
2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C 2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C
3- Outer Sheath : PVC (Polyvinyl Chloride) Flame Retardant : IEC 60332-1 3- Outer Sheath : PVC (Polyvinyl Chloride) Flame Retardant : IEC 60332-1
Min. Tensile Strength : 10.25 N/mm2 Min. Tensile Strength : 10.25 N/mm2
Dimension and Weight Electrical Properties Dimension and Weight Electrical Properties
No. of Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short No. of Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short
Cores Section Diameter Diameter Weight Carrying Circuit Cores Section Diameter Diameter Weight Carrying Circuit
Area (100m) Capacity Current Area (100m) Capacity Current
at 30°C at 30°C
Insulation Sheath Conductor Insulation 1 Sec Insulation Sheath Conductor Insulation 1 Sec
0.5 16 x 0.20 0.53 0.70 5.40 4.00 39.00 60 2.5 0.06 0.75 24 x 0.20 0.65 0.85 6.60 6.00 26.00 58 12 0.09
0.5 16 x 0.20 0.53 0.70 3.40 x 5.40 3.00 39.00 60 2.5 0.06 2 1 32 x 0.20 0.67 0.85 7.00 7.00 19.50 53 15 0.12
2
0.75 24 x 0.20 0.58 0.70 6.00 5.15 26.40 58 7 0.09 1.5 30 x 0.25 0.78 0.85 8.00 9.25 13.00 50 18 0.17
0.75 24 x 0.20 0.58 0.70 3.70 x 6.00 3.85 26.40 58 7 0.09 2.5 50 x 0.25 0.85 1.05 9.60 13.85 7.90 50 25 0.29
3 0.5 16 x 0.20 0.53 0.70 5.70 4.70 39.00 60 2.5 0.06 0.75 24 x 0.20 0.65 0.85 7.00 7.15 26.00 58 12 0.09
16 17
Federal Kabel Catalogue Federal Kabel Catalogue
Cu/PVC-f (NYAF)
Cu/PVC/PVC-f (NYYHY) 0.6/1 kV
Dimension and Weight Electrical Properties
No. of Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short
Cores Section Diameter Diameter Weight Carrying Circuit
Area (100m) Capacity Current
SPECIFICATION at 30°C
Insulation Sheath Conductor Insulation 1 Sec
SNI IEC 60502-1
Max. Min.
mm2 N x mm mm mm Kg A kA
Ω/km M.Ω.km
Dimension and Weight Electrical Properties 6 2.5 50 x 0.25 0.80 1.80 16.10 41.40 7.41 50 29 0.29
No. of Cross Conductor Thickness Overall Cable DC Resistance at 20°C Current Short 4.0 50 x 0.25 1.00 1.80 19.50 62.65 4.61 50 38 0.46
Cores Section Diameter Diameter Weight Carrying Circuit
Area (100m) Capacity Current 1.5 30 x 0.25 0.80 1.80 14.60 33.80 12.10 50 21 0.17
at 30°C 7 2.5 50 x 0.25 0.80 1.80 16.10 44.75 7.41 50 29 0.29
Insulation Sheath Conductor Insulation 1 Sec
Max. Min. 4.0 57 x 0.30 1.00 1.80 19.50 68.10 4.61 50 38 0.46
mm2 N x mm mm mm Kg A kA
Ω/km M.Ω.km
2.5 50 x 0.25 0.80 1.80 12.50 23.30 7.41 50 29 0.29 Available Colors
4 57 x 0.30 1.00 1.80 14.85 34.20 4.61 50 38 0.46
18 19
Federal Kabel Catalogue Federal Kabel Catalogue
No. of Cross Conductor Thickness Overall Cable Current Rating Voltage Drop
Cores Section Diameter Diameter Weight
Area (100m)
SPECIFICATION Insulation Sheath
Acc. to IEC 60331
mm2 N x mm mm mm Kg A Mv / A / m
1- Conductor : Annealed bunched copper wire Test Voltage : 3.5 kV / 5 Min 2.5 7 x 0.67 0.7 1.80 12.15 23.85 32 16
2- Shield Tape : Mica Tape Max. Operating Temperature : 90°C
4 7 x 0.85 0.7 1.80 13.30 30.95 42 10
3- Insulation : LSHF (Low Smoke Halogen Free) Flame Resistant : IEC 60331
4-Outer Sheath : LSHF (Low Smoke Halogen Free) Flame Retardant : IEC 60332 3 6 7 x 1.04 0.7 1.80 14.55 39.60 54 6.8
Smoke Emission : IEC 61304
Halogen Content : IEC 60754 10 7 x 1.35 0.7 1.80 16.55 56.50 75 4.0
Min. Tensile Strength : 12.75 N/mm2 16 7 x 1.70 0.7 1.80 18.80 79.60 100 2.5
Dimension and Weight Electrical Properties 1.5 7 x 0.53 0.7 1.80 12.00 22.10 23 27
No. of Cross Conductor Thickness Overall Cable Current Rating Voltage Drop 2.5 7 x 0.67 0.7 1.80 13.05 27.90 32 16
Cores Section Diameter Diameter Weight
4 7 x 0.85 0.7 1.80 14.35 36.65 42 10
Area (100m)
4 6 7 x 1.04 0.7 1.80 15.70 47.50 54 6.8
Insulation Sheath
10 7 x 1.35 0.7 1.80 17.95 68.60 75 4.0
mm2 N x mm mm mm Kg A Mv / A / m
16 7 x 1.70 0.7 1.80 20.50 97.65 100 2.5
1.5 7 x 0.53 0.7 1.80 6.60 6.25 25 27
25 7 x 2.14 0.9 1.80 24.65 147.55 127 1.65
2.5 7 x 0.67 0.7 1.80 7.00 7.60 33 16
20 21
Federal Kabel Catalogue Federal Kabel Catalogue
No. of Cross Conductor Thickness Braided Overall Cable DC Resistance at 20°C Current
Cores Section Diameter Shield Diameter Weight Carrying
Area (100m) Capacity
SPECIFICATION Insulation Sheath Conductor Insulation at 30°C
Construction General Characteristics 6 1 32 x 0.20 0.50 1.00 8 x 0.12/24 9.30 16.00 19.50 53 15
22 23
Federal Kabel Catalogue Federal Kabel Catalogue
Cu/PVC-f (NYAF)
TELEPHONE WIRE SPEAKER WIRE
SPECIFICATION SPECIFICATION
Conductor Acc. to Conductor Acc. to
IEC 60228 IEC 60228
APPLICATION APPLICATION
Mainly used for interconnection of indoor telephone Mainly used as the electrical connection between loudspeakers
equipment. Can also be used for interconnection of other and audio amplifiers, where setup requires installations behind
communication, control equipment or low-level signalling a wall or ceiling.
applications.
1- Conductor : Annealed plain copper wire Test Voltage : 800 V / 1 Min 1- Conductor : Annealed bunched copper wire Test Voltage : 800 V / 1 Min
2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C 2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C
3-Shield Tape : Mylar Tape *(M type) Insulation : JIS K 6723 3-Shield Tape : Paper Tape Insulation : JIS K 6723
4-Outer Sheath : PVC (Polyvinyl Chloride) Min. Tensile Strength : 10.25 N/mm2 4-Outer Sheath : PVC (Polyvinyl Chloride) Min. Tensile Strength : 8.00 N/mm2
Type Conductor Thickness Overall Cable DC Resistance at 20°C No. of Size Cross Section Conductor Thickness Overall Cable Weight
Diameter Diameter Weight Cores Area Diameter Diameter (100m)
Insulation Sheath (100m) Conductor Insulation Insulation Sheath
1 x 2C (M) 0.60 0.32 0.70 4.00 1.85 65 100 20 AWG 0.50 31 x 0.14 0.55 0.80 5.70 3.50
1 x 3C (M) 0.60 0.32 0.70 4.20 2.30 65 100 18 AWG 0.82 53 x 0.14 0.55 0.80 6.25 4.45
1 x 4C (M) 0.60 0.32 0.70 4.60 2.85 65 100 2 16 AWG 1.31 85 x 0.14 0.55 0.80 6.90 5.90
1 x 6C 0.60 0.32 0.85 5.40 4.10 65 100 14 AWG 2.00 4 x 32 / 0.14 0.60 0.90 8.75 8.85
1 x 8C 0.60 0.32 0.95 6.00 5.25 65 100 12 AWG 3.34 7 x 31 / 0.14 0.65 1.15 10.40 13.55
1 x 10C 0.60 0.32 1.00 6.60 6.45 65 100 20 AWG 0.50 31 x 0.14 0.55 0.80 6.60 5.65
1 x 12C 0.60 0.32 1.20 7.40 8.05 65 100 18 AWG 0.82 53 x 0.14 0.55 0.80 7.20 7.35
1 x 15C 0.60 0.32 1.20 8.00 9.50 65 100 4 16 AWG 1.31 85 x 0.14 0.55 0.80 7.95 9.80
1 x 20C 0.60 0.32 1.20 8.80 11.90 65 100 14 AWG 2.00 4 x 32 / 0.14 0.60 0.90 10.15 15.00
2 x 2C (M) 0.60 0.32 0.90 5.80 3.55 65 100 12 AWG 3.34 7 x 31 / 0.14 0.65 1.15 12.05 23.05
24 25
Federal Kabel Catalogue Federal Kabel Catalogue
SPECIFICATION SPECIFICATION
Conductor Acc. to SNI 04.6629-5
IEC 60228 60227 IEC 41
APPLICATION APPLICATION
Mainly used as the electrical connection between loudspeakers Mainly used as the electrical connection between loudspeakers
and audio amplifiers. Tinned to prevent corrosion and enhances and audio amplifiers. Also commonly used to connect light,
signals. portable general appliances.
1- Conductor : Tinned bunched copper wire Test Voltage : 800 V / 1 Min 1- Conductor : Annealed bunched copper wire Test Voltage : 2 kV / 5 Min
2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C 2- Insulation : PVC (Polyvinyl Chloride) Max. Operating Temperature : 70°C
Insulation : JIS K 6723 Min. Tensile Strength : 10.25 N/mm2
Min. Tensile Strength : 8.00 N/mm2
AWG Series Dimension and Weight AWG Series Dimension and Weight
Type Cross Section Conductor Thickness Overall Cable Weight Type Cross Section Conductor Thickness Overall Cable Weight
Area Diameter Diameter (100m) Area Diameter Diameter (100m)
2 x 24 AWG 0.20 18 x 0.12 1.00 2.60 x 5.20 1.65 2 x 25 AWG 0.15 10 x 0.14 0.80 2.20 x 4.40 1.35
2 x 22 AWG 0.33 29 x 0.12 1.00 2.75 x 5.50 2.00 2 x 23 AWG 0.26 21 x 0.14 1.00 2.70 x 5.40 2.05
2 x 20 AWG 0.52 2 x 23 / 0.12 1.00 3.35 x 6.70 3.00 2 x 21 AWG 0.40 26 x 0.14 1.00 2.85 x 5.70 2.45
2 x 18 AWG 0.80 3 x 23 / 0.12 1.20 3.85 x 7.70 4.05 2 x 19 AWG 0.65 32 x 0.14 1.00 3.05 x 6.10 3.10
2 x 16 AWG 1.31 4 x 29 / 0.12 1.40 4.60 x 9.20 6.10 2 x 17 AWG 1.00 32 x 0.20 1.00 3.30 x 6.60 4.00
2 x 14 AWG 2.00 6 x 29 / 0.12 1.60 5.45 x 10.90 8.65 2 x 16 AWG 1.33 27 x 0.25 1.00 3.55 x 7.10 4.80
Available Colors
Transparent
26 27
Federal Kabel Catalogue Federal Kabel Catalogue
Cu/PVC-f (NYAF)
MICROPHONE CABLE COAXIAL CABLE
SPECIFICATION SPECIFICATION
Conductor Acc. to Conductor Acc. to
IEC 60228 IEC 60228
APPLICATION APPLICATION
Designed to connect microphones, focusing on ruggedness, Coaxial cable is used as a transmission line for frequency
flexibility, flex-life and interference immunity to deliver clearer signals, computer network connections, digital audio, internal
sound signal. wiring of TV, radio receivers, VTR, Tape Recorders and other
equipments.
1- Conductor : Annealed bunched copper wire Max. Operating Temperature : 70°C 1- Conductor : Annealed plain copper wire Test Voltage : 1 kV / 1 Min
2- Insulation : PVC (Polyvinyl Chloride) Conductor : IEC 60228 2- Insulation : PE (Polyethylene) Max. Operating Temperature : 70°C
3- Shield Tape : Paper Tape (P-type) Insulation : JIS K 6723 3- Shield Tape : Aluminium Tape (-A type) Insulation : JIS K 6723
4- Shield Braid : Annealed plain copper wire Min. Tensile Strength : 8.00 N/mm2 4- Shield Braid : Annealed plain copper wire Min. Tensile Strength : 10.25 N/mm2
: Tinned Copper Wire (T-type) 5- Outer Sheath : PVC (Polyvinyl Chloride)
5- Outer Sheath : PVC (Polyvinyl Chloride)
Dimension and Weight Electrical Properties Dimension and Weight Electrical Properties
Type Cross Conductor Thickness Braided Overall Cable DC Resistance at 20°C Type Cross Conductor Thickness Braided Overall Cable DC Resistance at 20°C Wave
Section Diameter Shield Diameter Weight Section Diameter Shield Diameter Weight Impedance
Area Insulation Sheath (100m) Conductor Insulation Area Insulation Sheath (100m) Conductor Insulation
Twin 25 AWG 0.16 14 x 0.12 0.55 0.55 43 x 0.10 3.00 x 6.00 2.70 112.00 100 3C–2V 0.20 1 x 0.50 1.30 0.90 7 x 0.12/16 5.40 4.10 91.4 100 75
Mono 23 AWG 0.23 20 x 0.12 0.55 2.00 50 x 0.10 5.90 4.35 84.93 100 5C–2V 0.50 1 x 0.80 2.05 1.00 7 x 0.12/24 7.40 7.10 36.0 100 75
Stereo 23 AWG 0.23 20 x 0.12 0.55 1.10 7 x 0.10/16 6.00 4.70 84.93 100 RG 58 0.50 19 x 0.18 0.95 0.90 7 x 0.12/16 5.10 3.85 36.0 100 50
Stereo 22 AWG (PT) 0.31 39 x 0.10 0.55 1.05 8 x 0.10/16 6.00 5.10 50.60 100 RG 59 0.30 1 x 0.60 1.55 0.95 7 x 0.12/16 5.95 4.65 65.0 100 75
28 29
Federal Kabel’s trusted product quality has been very well accepted & proven
OUR PROJECTS LIST throughout the Asia, Middle East, Australia, America & Europe.
EUROPE
SINGAPORE
INDONESIA
With more than 100 dealers –
“we ensure that our customers AUSTRALIA
can easily get in touch with our
products anytime, anywhere.”
30 31