You are on page 1of 1

R.C.

C SLAB

1182
R.C.C SLAB

1182

1182
R.C.C SLAB

1419

1419
F.L F.L

414

414
R.C.C SLAB
G.L G.L G.L

768
ROOF LEVEL

EARTH
FILLING

#3@6" .

3'-6"
414 414 414
4079 4079 4079 4079
1810 1810

#3@8"
.
HANGING BEAM
HANGING BEAM

BEAM :1 BEAM :1 BATH BATH BATH BATH


5'X7' 5'X7' 5'X7' 5'X7'
ROOM ROOM ROOM ROOM
10'X12' 10'X12' 10'X12' 10'X12'

UP UP

2202

2202
TERRACE TERRACE TERRACE TERRACE

LAP LEN.
TYP

3'-6"
1ST FLOOR SEE SCHEDULE
UP UP

ROOM ROOM ROOM ROOM


COLUMN :1 COLUMN :1

PASSAGE WIDE 5'-9"

PASSAGE WIDE 5'-9"


BEAM :1 BEAM :1 10'X12' 10'X12' 10'X12' 10'X12'

#3@6".
BATH BATH

.
3+3-#4

3+3-#4

HANGING BEAM HANGING BEAM 5'X7' 5'X7'


BATH BATH
5'X7' 5'X7'

Projection Wide-312'
HANGING BEAM

HANGING BEAM

HANGING BEAM

HANGING BEAM

HANGING BEAM

HANGING BEAM

HANGING BEAM

HANGING BEAM
SIDE PASSAGE 15' WIDE
BATH BATH BATH BATH

3'-6"
5'X7' 5'X7' 5'X7' 5'X7'
BEAM :1 BEAM :2 BEAM :3 BEAM :1 BEAM :2 BEAM :3 ROOM ROOM ROOM ROOM

2202

2202
10'X12' 10'X12' 10'X12' 10'X12'
#4@ 4" C/C A A

TERRACE TERRACE TERRACE TERRACE

#3@8"
.
BEAM :1 BEAM :1

9695

9695

9695

9695
HANGING BEAM HANGING BEAM

PASSAGE WIDE 5'-9"

PASSAGE WIDE 5'-9"


ROOM ROOM
BASEMENT GROUND FLOOR ROOM 10'X12' ROOM 10'X12'
10'X12' 10'X12'
HALL HALL BATH BATH
5'X7'
BATH BATH
5'X7'
5'X7' 5'X7'
RAMP UP TO
GROUND FLOOR

384

2202

2202
BATH BATH
BATH BATH
5'X7' 5'X7'
5'X7' 5'X7'
ROOM ROOM ROOM ROOM

PER ARCH.
10'X12' 10'X12' 10'X12' 10'X12'
SEE SCHEDULE

AS
R.L

Projection Wide-321'
BEAM :1 BEAM :1

PER SITE
HANGING BEAM HANGING BEAM TERRACE TERRACE

LAP LEN.
AS
TERRACE TERRACE

TYP
E.G.L

AS PER SITE
#3@6"
.
ROOM ROOM ROOM ROOM
10'X10'-3" 10'X10'-3" BATH 10'X10'-3" 10'X10'-3" BATH
BATH 5'X7' BATH 5'X7'
Reception
5'X7' 5'X7'

5'-0"
C C
#4@ 4" C/C #4@ 4" C/C #4@ 4" C/C
DN DN
3-#4 #4@ 4" C/C

T
Lounge+Stair hall Lounge+Stair hall
BEAM :1 BEAM :1 UP UP

t
36'-10"X8'-4" 36'-10"X8'-4"
P.C.C. (1:4:8)

4"
HANGING BEAM 1
7'-58 XxY 89

"
#3@ 8.5 C/C (TYP.) COLUMN ELEVATION
#3@ 8.5 C/C
#3@ 8.5 C/C
#3@ 8.5 C/C

RAMP UP TO
GROUND FLOOR

G.T ROAD

ADDITIONAL TOP STEEL

ADDITIONAL TOP STEEL ADDITIONAL TOP STEEL


TOP STEEL+
ADDITIONAL TOP STEEL TOP STEEL TOP STEEL+ TOP STEEL TOP STEEL+
(FULL LENGTH) ADDITIONAL TOP STEEL (FULL LENGTH) ADDITIONAL TOP STEEL Detailing Detailing

COL. TIES
Dimension Dimension
L/4 L/3 L/3 L/3 L/3
Hook
A or G

CONT. ALL COLUMN TIES CONT. ALL COLUMN TIES


Stirrups Stirrups Stirrups Stirrups Stirrups Stirrups Stirrups
@75 C/C FOR < 375 WIDE COLUMNS. @75 C/C FOR < 375 WIDE COLUMNS.
As Per Section As Per Section As Per Section As Per Section As Per Section As Per Section As Per Section BEAM BARS BEAM BARS @100 C/C FOR > 375 WIDE COLUMNS.
(TYP.) @100 C/C FOR > 375 WIDE COLUMNS. (TYP.) db D .

db D .

J
.
.

b
L/8 L/8 L/8 L/8 L/8

A or G
BOTM. STEEL BOTM. STEEL
BOTM. STEEL (FULL LENGTH+ BOTM. STEEL (FULL LENGTH+ BOTM. STEEL

12d
(FULL LENGTH) ADDITIONAL TOP STEEL) (FULL LENGTH) ADDITIONAL TOP STEEL) (FULL LENGTH) 4d b
or

2½" Min.
1 TYPICAL BEAM ELEVATION
BEAM TIES BEAM TIES BEAM TIES BEAM TIES

D
90° 180°

D
ADDITIONAL TOP STEEL

COL. TIES
ADDITIONAL TOP STEEL ADDITIONAL TOP STEEL
TOP STEEL+

COL. TIES
ADDITIONAL TOP STEEL TOP STEEL
(FULL LENGTH)
TOP STEEL+
ADDITIONAL TOP STEEL
TOP STEEL
(FULL LENGTH)
TOP STEEL+
ADDITIONAL TOP STEEL
2.0 D 2.0 D 2.0 D 2.0 D
12d for #6, #7, #8
L/4 L/3 L/3 L/3 L/3 b
6d for #3, #4, #5
b
Stirrups Stirrups Stirrups Stirrups Stirrups Stirrups Stirrups or 2½ in. minimum
As Per Section As Per Section As Per Section As Per Section As Per Section As Per Section As Per Section

A or G
.

A or G
L/8 BOTM. STEEL ADDITIONAL L/8 L/8 BOTM. STEEL ADDITIONAL L/8 L/8
(FULL LENGTH) BOTM. STEEL (FULL LENGTH) BOTM. STEEL
TYP. BEAM/COL. CONNECTION TYP. BEAM/COL. CONNECTION
.

.
INTERMED. CONNECTION AT ROOF LEVEL

H
.

2 TYPICAL BEAM ELEVATION INTERMEDIATE CONNECTION

H
D D D

Dimension
Detailing
A or G

b
6d
or
2½"
Dimension

Dimension
Detailing

Detailing

min.

10d
b
COL. TIES

CONT. ALL COLUMN TIES


CONT. ALL COLUMN TIES
d d

b b d

b
(1) - WORK THIS DRAWING WITH ALL OTHER RELEVENT DRAWINGS. @75 C/C FOR < 375 WIDE COLUMNS. D D
@75 C/C FOR < 375 WIDE COLUMNS. @100 C/C FOR > 375 WIDE COLUMNS. . .

(2) - FOR DIMENSIONS & FLOOR LEVELS REFER TO ARCHITECTURAL DRAWINGS. @100 C/C FOR > 375 WIDE COLUMNS.
(3) - IN CASE OF ANY DOUBT/CONFUSION IN STRUCTURAL DRAWINGS, 90° 135°
PLEASE ASK BEFORE EXECUTION OF WORK. BEAM TIES 135-DEG SEISMIC

D
BEAM TIES STIRRUP AND TIE HOOKS
D

(4) - USE PORTLAND CEMENT CONCRETE AS UNDER STIRRUP/TIE HOOKS


(a) - FOR ALL STRUCTURAL MEMBERS EXCEPT COLUMNS USE MINIMUM MIX(1:2:4)

COL. TIES
WITH 3000 PSI. CYLINDER STRENGTH AT 28 DAYS. 2.0 D
COL. TIES

2.0 D
(b) - FOR ALL COLUMNS USE MINIMUM MIX (1:1½:3) WITH 3750 PSI. Stirrups and tie 135 deg Stirrup-tie
hook dimensions, in. hook dimensions, in.
CYLINDER STRENGTH AT 28 DAYS.
(5) - USE GRADE-60 STEEL REINFORCING BARS WITH MIN. TENSILE YIELD STRENGTH Bar D 90-deg hooks 135-deg hooks 135-deg hooks
TYP. BEAM/COL. CONNECTION TYP. BEAM/COL. CONNECTION
OF FY = 60,000 PSI AS PER ASTM SPECIFICATIONS. Size (in.)
H
INTERMEDIATE CONNECTION AT EDGE CORNER CONNECTION AT ROOF LEVEL A or G, A or G,
H
approx A or G, in. approx
(6) - ALL LAP LENGTH SHOULD BE 50-DIA OF BARS UP TO #5 BAR
AND 60-DIA FOR #6 AND ABOVE. #3 1½ 4 4 2½ 5 3½

(7) - FOLLOWING ARE CLEAR CONCRETE COVERS TO BARS, TYP. BEAM/COL. CONNECTION #4 2 4½ 4½
3
3 6½ 4½

3
#6 4½ 12 7 4 4½ 10 4 6½
(I) - SLAB TOP AND BOTTOM----------------------- 3/4" JOINTS DETAIL
(II) - BEAMS -------------TOP AND BOTTOM 1½" & SIDES 1"
RECOMENDED END HOOKS, ALL GRADES
(III) - COLUMNS ------------------------------- 1½"
Finished

bend
(IV) - FOOTINGS ------------------------------- 2"
Bar diameter 180-deg hooks 90-deg hooks
Size D,in.
(V) - RETAINING WALL & WATER STRUCTURE -----2" A or G, in. J, in. A or G, in.

(8) - USE #3@12"c/c AS DISTRIBUTION STEEL FOR BINDING ALL TOP BARS IN SLABS. #3 2¼ 5 3 6

#4 3 6 4 8
(9) - THE CONSTRUCTION WORK MUST BE SUPERVISED BY QUALIFIED CIVIL ENGINEER.
#6 4½ 8 6 12
(10) - SAFTY OF ADJACENT BUILDINGS DURING CONSTRUCTION
#8 6 11 8 16
WORK MUST BE ASSURED TO AVOID ANY DAMAGES.
(11) - DEVELOPMENT LENGTH SHOULD BE 18-DIA OF BAR.
(12) - USE ELECTROMECHANICAL VIBRATOR FOR COMPACTION OF CONCRETE. TYP. BEAM/COLUMN
HOOKS DETAIL
(13) - PROVIDE CAMBER(RAISE THE SHUTTERING) IN SLABS/BEAMS OF (SPAN/240) OR AS MANTIONED IN DWG.

You might also like