Annexure-A Rev-03

AC BOM for 33 kV Project - 100MW BHADLA


Erection of 33 kV Switchyard
BLOCK P-8 BLOCK P-9
Sr no. Description Specification UOM TOTAL QTY
(QTY) (QTY) unit price total Amount
33kV Yard (MCR END)
MCT: - 33kV, Ratio 600/1-1A for Stand By metering
1 Indoor type Metering cubicle MPT: - 33kV, for Stand By Tariff Metering. Set 2 2 4 10000 20000
2 TARIFF METER TARIFF METER: - 33kV, 600/1A, ABT Meters, Indoor type Set 2 2 4 5000 10000
3 Aux transformer 100kVA, 33/0.415kV Aux. transformer Nos 1 1 2 5000 5000
4 Indoor Type Main ACDB cum Ups DB 415 V, 3ph, 4 W, ACDB (Indoor) - for complete AC power distribution Nos 1 1 2 5000 5000
5 Heat-Shrinkable Indoor Termination kits 33 KV, 3C x 300 mm2 Aluminium Armoured XLPE Earth Grade cable from Nos 2 2 4 10000 20000
Auxiliary Trafo to VCB 0
6 Heat-Shrinkable Indoor Termination kits for 33 KV, 3C x 300 mm2 Aluminium Armoured XLPE Earth Grade cable Nos 8 8 16 5000 40000
from main Outgoing to Metering cubicle 0
7 300 Sqmm Al Cable 19/33 KV, 2R,3C x 300 mm2 Aluminium Armoured XLPE Earth Grade Cable Mtr. 60 60 120 70 4200
from Main Outgoing to Metering Cubicle 0
19/33 KV, 3C x 300 mm2 Aluminium Armoured XLPE Earth Grade Cable 0
8 300 Sqmm Al Cable from Auxiliary Trafo to VCB Mtr. 40 40 80 70 2800
9 185 Sqmm Al Cable 1.1kv KV, 3.5C x 185 mm2 Aluminium Armoured XLPE Grade Cable from Mtr. 40 40 80 50 2000
Auxiliary Trafo to Main LT ACDB
10 35 Sqmm Al Cable 1100 V, XLPE insulated, armoured, Aluminium cable - 3.5 core x 35 mm2 Mtr. 20 20 40 40 800
from Main ACDB to Battery & Battery Charger

11 LT Control Cables (2.5 Sqmm, 4 Sqmm and 6 sqmm /or as Required with 3 Core, 4 Core, 7
Core, 10 Core cables) for Control wiring i.e… Metering CTs, PTs, Protection
CTs, PTs, Breakers, Control and Relay Panel, Isolator, Battery charger, Lot 1 1 2 50000 50000
Isolator, Yard Lighting, ABT Meter etc..
Note: Metering CTs, PTs wiring should be armoured 4C X 4 sqmm copper
Multistrand Cable only.

L.T cable,12C x 2.5 sq.mm Cu. Arm. 1.1kV Cable Multistrand


L.T cable,4C x 2.5 sq.mm Cu. Arm. 1.1kV Cable Multistrand
L.T cable,3C x 2.5 sq.mm Cu. Arm. 1.1kV Cable Multistrand
L.T cable,3C x 6 sq.mm Al. Arm. 1.1kV Cable Multistrand
L.T cable,4C x 4 sq.mm Cu.. Uarm. 1.1kV Cable Multistrand PVC
12 33kV VCB PANEL BOARD 33kV Indoor 10no. VCB Panel Board SET 1 1 2 80000 80000
For Cable diffrential MCR END to PSS END with HDPE Pipe 0
13 FO CABLE Note: Which include cable jointing if required, terminations at both the ends, Mtr. 2,200 3,600 5,800 20 44000
supply & installation of require accessories. 0
14 Battery, battery charger & DCDB Battery Set 1 1 2 10000 10000
Battery Charger & DCDB with accessories 0
15 Consumable & miscellaneous Clamp & Connectors, Glands, Lugs, Ferrules, Ties, Tags, insulation tapes, Lot 1 1 2 10000 10000
Galvanized cable tray, coupler, G.I Pipes etc. 0
40 mm GI Pipes as per IS standards, GI Strip,Shield wire, MS Rods, Copper 0
16 Earth Mat Plates, Copper Strip, Riser Material, Flexible Copper Strips, Earth Pits Lot 1 1 2 50000 50000
including earthing materials like Charcoal, salt etc. 0
Chemical Earthing pits 0
17 Air Conditioner Air Conditioner for SCADA Room No 1 1 2 10000 10000
18 Illumination System 100W LED Light with Fixture for Outdoor Electrification of MCR No 6 6 12 1000 6000
Internal Electrification of exhaust fan, ceiling fan inside the MCR Lot 1 1 2 50000 50000
19 Safety Material Required Safety material for 33 KV Switchyard as per requirement Lot 1 1 2 20000 20000
a Fire Extingusher:
b Fire Extingusher:
c Fire Extingusher Ball
d Danger boards
e Fire Bucket stand
f First aid Box
g First-aid chart
h Rubber Hand gloves
i Rubber Mat
j Discharge Rod
18 Fire Alarm System Fire Alarm System for MCR Nos. 1 1 2 5000 5000
19 UPS 5kVA UPS Nos 1 1 2 5000 5000
20 Lightning Spike 3 Mtr. Long Lightning Spike for lightning Protection Nos 4 4 8 2000 8000
SCADA WORK
21 SCADA WORK SCADA Works and Data Communication to SLDC/Pooling Station & FO Job 1 1 2 30000 30000
Cable
PSS END WORK
23 Metering CT MCT: - 33kV, Ratio 600/1-1A for Main & Check metering No. 6 6 12 4000 24000
MCT: - 33kV, Ratio 600/1-1A for Stand By metering No. 6 6 12 4000 24000
24 Metering PT MPT: - 33kV, for Main & Check Tariff Metering. No. 6 6 12 3000 18000
MPT: - 33kV, for Stand By Tariff Metering. No. 6 6 12 3000 18000
25 Galvanized Str. Galvanized Structure for CT,PT, 4 Cable Support Str. Lot 1 1 2 70000 70000
26 ACSR Conductor ACSR Zebra Conductor Mtr. 80 80 160 80 6400
27 Cable Support Str. With Post Insulator Cable Support Str. With Post Insulator Set 2 2 4 5000 10000
28 Clamps & Connector Clamps & Connector Suitable for ACSR Zebra Lot 1 1 2 10000 10000
29 Metering system(RRVPNL) TARIFF METER: - 33kV, _ /1A, ABT Meters, Outdoor Type Set 2 2 4 10000 20000
30 Metering system(RRVPNL) TARIFF METER: - 33kV, _ /1A, ABT Meters, Outdoor Type Set 2 2 4 10000 20000
31 Consumable & miscellaneous Clamp & Connector Glands, Lugs, Ferrules, Ties, Tags, insulation tapes, Lot 1 1 2 10000 10000
Galvanized cable tray, coupler, G.I Pipes etc.)
32 Heat-Shrinkable Indoor / Outdoor Termination kits at for 33 KV, 3C x 185 mm2 Aluminium Armoured XLPE Earth Grade cable Lot 12 12 24 1000 12000
PSS end
AC BOM for 33 kV Project - 100MW (12.5MW BLOCK-P8 & P9) (BHADLA)
No of Inverter Transformer Yards- 8 Nos
1 3.125MW Inverter 3.125MW Central Inverter Nos 16 16 32 10000 160000
2 ICOG PANEL 33 kV, 630 A, 25 kA for 1sec, Outdoor VCB for each 12.5 MVA Traformers Nos 4 4 8 1000 4000
3 12.5 MVA Inverter Transformer 0.600-0.600-0.600-0.600/33 kV, OFF CKT TAP ± 7.5% & Z=6%, Copper Nos 4 4 8 200000 800000
wound ONAN Transformer
4 NIFPS NIFPS as per requirement Nos 4 4 8 10000 40000
5 UPS ( Outdoor) 2kVA UPS with Battery supply with 1 hrs backup with DB Nos 4 4 8 5000 20000
6 Aux transformer with DB 15kVA, 600/415V Aux. transformer with Distribution board Nos 4 4 8 5000 20000
HT, LT & Control Cables with Terminations
7 300 sqmm Al.cable 1C x 300 mm2, 1.9/3.3 kV,Al. Cable for Inverter to 12.5MVA Transformer Mtr. 8,640 8,640 17,280 20 172800
8 300mm2 AL cable 19/33KV, 3C x 300 mm2 Aluminium Armoured XLPE ( E) Grade Cable (to Mtr. 7,500 5,000 12,500 70 525000
be laid undergound) from 33kV Group yard to 33KV HT Panel(MCR)
33KV, 3C x 300 mm2 Aluminium Armoured XLPE Grade ( E) Cable from
9 300mm2 AL cable 33kV Transformer to 33kV ICOG Panel Mtr. 100 100 200 70 7000
10 16mm2 AL cable 1100 V, XLPE insulated, armoured, Aluminium cable - 4 core x 16mm2 from Mtr. 2,000 2,000 4,000 20 40000
ICR DB to ICR DB
LT Control Cables : (2.5 Sqmm, 4 Sqmm and 6 sqmm /or as Required with
11 Control Cables 3 Core, 4 Core, 7 Core, 10 Core cables) for Control wiring Lot. 1 1 2 30000 30000

L.T cable,12C x 2.5 sq.mm Cu. Arm. 1.1kV Cable Multistrand


L.T cable,3C x 2.5 sq.mm Cu. Arm. 1.1kV Cable Multistrand
L.T cable,4C x 2.5 sq.mm Cu. Arm. 1.1kV Cable Multistrand
L.T cable,3C x 6 sq.mm Al. Arm. 1.1kV Cable Multistrand
BLOCK P-8 BLOCK P-9
Sr no. Description Specification UOM TOTAL QTY
(QTY) (QTY)
12 Bi metalic. Lugs (300Sqmm) BI METEALIC .Lugs for Inverter & Transformer connections (for 1Cx300 Nos. 864 864 1,728 50 43200
sqmm Al cables)
13 Dealseal Dealseal for IDT transformer Nos. 144 144 288 50 7200
14 DC Glands (PVC) DC gland for Inverter & Transformer connections (for 1Cx300 sqmm Al Nos 432 432 864 50 21600
cables)
15 Heat-Shrinkable Termination kits for 33KV, 3 Core x 300 mm2 Aluminium Armoured XLPE cable Nos 20 20 40 1000 20000
16 Heat-Shrinkable Outdoor Straight-Joint kits for 33KV, 3 Core x 300 mm2 Aluminium Armoured XLPE cable Nos 6 6 12 1500 9000
Earthing & Miscellaneous
17 40 mm GI Pipes, GI Strip, Earthing Rods, Copper Plates, Copper Strip,
Riser Material, Flexible Copper Strips, Earth Pits including earthing materials Lot 4 4 8 50000 200000
like Charcoal and salt etc. or chemical Earthing
Earthing Materials 40 mm GI Pipes, GI Strip, Earthing Rods, Copper Plates, Copper Strip,
18 Riser Material, Flexible Copper Strips, Earth Pits including earthing materials Lot 4 4 8 10000 40000
Inverter Earthing like Charcoal and salt etc. with 1C x 70 sq. mm copper cable
19 Hot dipped GI Cable Trays & covers, Couplers, GI Pipes, Glands, Lugs, Lot 4 4 8 10000 40000
Consumables & Miscellaneous Ferrules, Ties, Cable Tags, Shield Wire, HS Sleeves etc.
20 Cable support Str in ICR yards (GI Painted) Lot 4 4 8 25000 100000
Cable support Str. in ICR yards 100Watt LED light Fixture 20 20 40 1000 20000
21 4.7Mtr. Pole with fixing arrangement & Hardware No 8 8 16 1000 8000
33kV yard Light Junction Box. 8 8 16 500 4000
Safety Materials
22 Safety Material Required Safety material for ICR yard as per requirement lot 1 1 2 20000 20000
Fire Extinguisher
Fire Extinguisher
Fire Extinguisher
Fire Extingusher Ball
Danger Board
Fire Bucket stand
Rubber Hand Gloves
First-AID box
First-aid chart
Fire blanket
Rubber Mat

Total 3082000
Consumables and Miscellaneous are added on Annexure-B 235000
Total amount wothout tax with consumables 3317000

NOTE: 1. Consumables and Miscellaneous are added on Annexure-B


2. Transformer dehydration shall be in erection contractors's scope of work.