Page 1

Diesel engine D 2876 LE20x 23.07.03


Technical Data
preliminary

MVI

Engine type: four-stroke, direct-injection

Cylinders : 6 cylinder in line, wet replaceable cylinder liners

Aspiration : turbocharger, intercooler

Cooling : water circulation by centrifugal pump on engine

Lubrication: force-feed lubrication by gear pump, lubricating oil cooler


in cooling water circuit of engine

Injection: Bosch in-line pump with integrated, electromagnetic actuador

Generator: Bosch three-phase generator with rectifier and transistorized


governor, 28 V, 80 A

Starter motor: Bosch solenoid-operated starter, typ KB, 24 V, 5.4 kW

Bore : 128 mm Starter battery capacity 143 Ah (24V)

Stroke : 166 mm Filling capacities:


Engine lube oil for
Volume : 12.82 l - oil sump standard (min./max.) 34 / 40 l
- oil sump shallow (min./max.) 24 / 30 l
Compression ratio: 15.5:1 - oil sump for automatic refilling 34 / 40 l
(min./max.)

LE 201
Cooling water temperat LE 203 Inertia moments (SI-Unit):
/202
- under normal conditio 90 °C 100 °C - engine and vibration damper ---
- short period under - flywheel for
extreme conditions 95 °C 105 °C generator drive 1500 rpm 2.392 kgm2
- before start of generator drive 1800 rpm 2.392 kgm2
full load (min.) 40 °C 40 °C

Filling capacities:
- engine cooling water 13.3 l Steady-state speed accuracy (speed droop)
- cooling water for radiator - electronical governor 0-8%
with pipe system abt. 35 l

Negative pressure at air filter Exhaust gas back pressure


outlet, max. permissible (in a max. permissible 60 hPa
new condition/ after
30 / 60 hPa
usage)
Diesel engine D 2876 LE20x Page 2
23.07.03
Technical Data
preliminary

MVI
LE202 LE201 LE203
(COP) (PRP) (LTP)
speed rpm 1500 1500 1500
ISO net brake fuel stop rating kW 341 391 451
Mean effective pressure bar 21.3 24.4 28.1
Torque Nm 2171 2489 2871

ISO Standard rating ¹) kW 310 355 410


Mean effective pressure bar 19.3 22.2 25.6
Torque Nm 1973 2260 2610
Mean piston velocity m/s 8.30 8.30 8.30

Specific fuel consumption ¹)


100% load g/kWh 208 209 212
75% load g/kWh 207 207 208
50% load g/kWh 209 208 206
Lube oil consumpt. max. g/h 320 370 435

Air for combustion m³/h 1160 1300 1475

Exhaust gas heat ²) KW 244 279 328


Exhaust gas temp. after turbocharger °C 560 570 585
Exhaust gas mass flow kg/h 1490 1675 1900
Exhaust gas vol. flow ²) m³/h 3555 4040 4675

Jacket water heat ²) kW 127 140 157


Minimum cooling water circulation l/min 400 400 400

Intercooler heat rate kW 47 62 80


Intercooler heat temp. before cooler °C 150 175 200

Residual energy (radiation, etc.) kW 60 70 84

Cooling air requirements for


fan-cooled radiator m³/h 17280 17280 17280

Power input for fan kW 14 14 14


Noise pressure level at 1 m
distance
(incl. fan) dB(A) --- --- ---

Weight including cooling system


(dry) kg 1180 1180 1180

¹) The nominal ratings and the specific fuel consumption are based on DIN ISO 3046/1, reference conditions
according to 298 K ( 25° Celsius ) air temperature, 100 kPa ( 1000 mbar ) air pressure, 60 % relative air
humidity; deratings for site conditions to be taken into account. Definition of engine application to ISO 8528-1

²) Data are for engine with non-cooled exhaust manifold.

The power-related data are relative to ISO standard rating.

Technical data are subject to alterations.


Diesel engine D 2876 LE20x Page 3
23.07.03
Technical Data
preliminary

MVI
LE202 LE201 LE203
(COP) (PRP) (LTP)
speed rpm 1800 1800 1800
ISO net brake fuel stop rating kW 396 446 507
Mean effective pressure bar 20.6 23.2 26.4
Torque Nm 2101 2366 2690

ISO Standard rating ¹) kW 360 405 461


Mean effective pressure bar 18.7 21.1 24.0
Torque Nm 1910 2149 2446
Mean piston velocity m/s 9.96 9.96 9.96

Specific fuel consumption ¹)


100% load g/kWh 213 215 222
75% load g/kWh 211 211 211
50% load g/kWh 213 212 212
Lube oil consumpt. max. g/h 380 435 510

Air for combustion m³/h 1600 1720 1860

Exhaust gas heat ²) KW 288 328 386


Exhaust gas temp. after turbocharger °C 495 520 555
Exhaust gas mass flow kg/h 2020 2190 2370
Exhaust gas vol. flow ²) m³/h 4460 4965 5640

Jacket water heat ²) kW 124 150 174


Minimum cooling water circulation l/min 460 460 460

Intercooler heat rate kW 80 98 120


Intercooler heat temp. before cooler °C 175 195 220

Residual energy (radiation, etc.) kW 81 85 105

Cooling air requirements for


fan-cooled radiator m³/h 23760 23760 23760

Power input for fan kW 24 24 24


Noise pressure level at 1 m
distance
(incl. fan) dB(A) --- --- ---

Weight including cooling system


(dry) kg 1180 1180 1180

¹) The nominal ratings and the specific fuel consumption are based on DIN ISO 3046/1, reference conditions
according to 298 K ( 25° Celsius ) air temperature, 100 kPa ( 1000 mbar ) air pressure, 60 % relative air
humidity; deratings for site conditions to be taken into account. Definition of engine application to ISO 8528-1

²) Data are for engine with non-cooled exhaust manifold.

The power-related data are relative to ISO standard rating.

Technical data are subject to alterations.