You are on page 1of 1

10.

00
POLY CARBONATE ROOFING

1.68 1.66 1.66 1.66 1.66 1.68 2-2X6X¼ C-PURLINS

2X4 C-PURLINS GA 1.2


9MM RSB SAGROD 150MM THK.
2.00 2.00 CHB
RAFTER TRUSS DETAIL
Ø10@600
HOR. BARS
NATURAL GRADE LINE

Ø10@600
VERT. BARS

600
LDG
B
G
IN

250
12.00
S T 12.00

9.70 E XI 9.70 G-20mm GRAVEL 3-Ø10mm


BEDDING Ø10mm @300 CUT BARS
400

0.30 0.60

0.40 MTS.

0.30 0.30 2
S-2
WALL FOOTING DETAIL
SCALE 1:20M

2.50 5.50 2.00

10.00

1 ROOF FRAMING PLAN


S-2 SCALE 1:100M.

12 THK. EXPANSION JOINT 12 THK. EXPANSION JOINT 1 - 16 MM DIA. BAR 1 - 16 MM DIA. BAR
WITH MASTIC FILLER WITH MASTIC FILLER

CHB WALL CHB WALL

FOR SIZE AND SPACING FOR SIZE AND SPACING


0.40 MTS.

0.40 MTS.
(DOWEL)

(DOWEL)
OF HOR. & VERT. BARS OF HOR. & VERT. BARS
SEE CONSTRUCTION NOTES SEE CONSTRUCTION NOTES
1 - 16 MM DIA. BAR 1 - 16 MM DIA. BAR
CHB WALL CHB WALL

FOR SIZE AND SPACING FOR SIZE AND SPACING


OF HOR. & VERT. BARS OF HOR. & VERT. BARS
SEE CONSTRUCTION NOTES SEE CONSTRUCTION NOTES

CORNER WALL DETAIL CORNER WALL DETAIL OPENING OR END WALL OPENING OR END WALL

3
S-2
MASONRY WALL DETAIL
SCALE NTS

This drawing or prints is ENGINEER : DATE : OWNER : PROJECT TITLE : CADD BY: NO. REVISIONS DATE SHEET NO :
property of the architect and
such not be copied,
reproduced, and used as an
instrument for construction
or exhibited without their
PROPOSED HOUSE EXTENSION & DATE :
prior notice and
permission.All drawings are
not be returned upon
request.
PRC NO : TIN :
PERIMTER FENCE CHECKED BY : AS SHOWN S-1
RA 545 PTR NO : PLACE : ADDRESS: LOCATION : DESIGNED BY :