You are on page 1of 1

Format No POT/01 Rev. No.

00

TEST REPORT
TEST REPORT ISSUED BY:LOCATION-01: VASAI LAB (TEST) SAMPLE TESTED BY/AT:LOCATION-01: VASAI LAB (TEST)
TEST REPORT NO. VST-6878-TR-292818
TEST REPORT DATE 26/04/2019

CUSTOMER NAME & ADDRESS: PROJECT SITE ADDRESS:


M/s Eximius Trading Pvt Ltd, Mahindra Project,
5 MG Road, 305 Tej House, Nandore Village, Near Oswal Heights,
Pune, Palghar (east)

QUANTITY: 3 Nos
DATE OF RECEIPT: 24/04/2019
CUSTOMER REF. NO & DATE: Letter Dated:24/04/2019
CONDITION OF SAMPLE ON RECEIPT: Satisfactory
SOURCE OF SAMPLE: Block-7, Gr. Floor 1 Rk
TEST METHOD: ASTM D7234-12

PULL OFF ADHESION STRENGTH TEST REPORT

Equipment ID : PosiTest Adhesion Tester (Sr. No: AT 11263)


Thickness of Bonding Layer(mm) : 10 Date Of Casting : 13/04/2019
Type of Substrate : RCC Column Date of Testing : 24/04/2019
Water Demand(%) :NA Age of Testing : 11 Days
Bonding Product :RCC Column with hacking + Gypsum
Sr. Location ID Mark Dolly Size Pull Off Adhesion Nature of Failure
No. (mm) Strength
(MPa)
1 RCC Column With Hacking + 50 0.98 Adhesive failure-Bond break between Gypsum
Gypsum and RCC
2 RCC Column With Hacking + 50 1.04 Adhesive failure-Bond break between Gypsum
Gypsum and RCC
3 RCC Column With Hacking + 50 1.05 Adhesive failure-Bond break between Gypsum
Gypsum and RCC
Average 1.02
Remarks: * Thickness of Bonding Layer(mm), Date Of Casting & Water Demand(%) is reported as per information given by customer.

NOTE:
-- Sample/s was/were not drawn by laboratory.
-- The Reported result/s is/are valid only to the sample submitted to the laboratory.
-- No part of the report, except in full, shall be reproduced without written consent of the laboratory.
-- The report is valid only when Global Lab hologram is available on the report.

******************End of Report******************

Authorized Signatory

Page 1 of 1