You are on page 1of 6

A structured

approach
to facades

systemkat_07_VERS-E.indd 1 06.09.2007 17:22:19 Uhr


Advantages of
ventilated facades
Building physics
Rain protector / humidity /
dew protector Thermal insulation-Cold Sound insulation

Thermal insulation-Heat Thermal expansion Fire safety / lighting arrester

Versatile facade design Alignment and levelling Large tolerances

www.eurofox.com

www.eurofoxengineering.com www.eurofox.com 3

systemkat_07_VERS-E.indd 3 06.09.2007 17:22:28 Uhr


Service package
EUROFOX project specific assesment with installation drawing
We can create a “project specific” assessment for your scheme – including static calculations.
We can provide an installation plan and a EUROFOX components schedule.

EUROFOX static analysis


■ Primary fixing dimensions in accordance with local authority regulations and
local pull out testing (primary fixing)
■ Verification of flexible points (dynamic load / pressure) and fixed points
(deadload, cladding and windloads)
■ Verification of profiles

Verification of sliding points GP - S V 40


Verification of anchor points 1x FP - M /2 V 40

STATICAL ANALYSIS
(horizontal loads only)
k

input data W1,2 = 0,1307 cm�


Dzul = 1,60 kN n= 1 d = 1,85 cm
Verification in section 4: Wb,4 = 0,0417 cm� Wt,4 = 0,1667 cm�
Szul = 0,80 kN m= 2 f = 3,69 cm
a

d = 1,85 cm h 1 = 6,00 cm e1 = 2,60 cm


system: Zweifeldtr‰ger
Nr.: 0 Felder: 2
� zul � W 1, 2 f
tension: H zul,1 = � � 0,89 kN 80% � v , zul
profile length L= 3,00 m �f � 0 , 75 � d
G zul,4 = 2
� 0,54 kN 34%
2
� d � e1 � � �
� � 3�� d �
a

cantilever length k= 0,435 m


� zul � W 1 , 2 �
H zul,2 = � 1,19 kN 60% �W �h � �W �
site: Example of static effective span a= 1,065 m �d � 0 , 75 � � b,4 1 � � t ,4 �
k

unit spacing b= 0,60 m


f
H zul,D = � n � D zul � 1,07 kN 67%
�f � d� verification by the permissible bolt / rivet shear force: bolts / rivets
2
loading: �= H/G= 3,954 v = 0,1667 x= 0,500
wind load acc. To ÷N B 4014 / T1 �� = 3,954 e = 3,00 cm 0,500
vorh H s = 0,71 kN � min H s,zul = 0,89 kN 80%
HS / G = j=

facade element HPL 6 mm

terrain categories GF I c druck = 1,000 wd = 0,81 kN/m� S zul


G zul,S = � 0,32 kN 56,9%
q0= 0,81 kN/m� c sog = 1,375 ws = 1,11 kN/m�
compression: e1 = 2,6 cm t = 0,25 cm �e � v � j � � �2 � x 2
vorh H s = | 0,712 kN | w= 1,11 kN/m�
��= e 1 � 12
max
� 36,0
max H= 0,71 kN t
support structure MTA_v-100
vorh H d = | 0,518 kN |
� = 1,15 A4 = 1,50 cm� verification by the permissible dowel force: 1 dowel

� � A4 f = 3,69 cm 0,0000
wall weight g= 0,10 kN/m� G= 0,180 kN Hd ,zul, 4 = zul
� 13,04 kN 4% Dzul = 1,60 kN w=

company Mustermontage material: Al Mg Si 0,5 F25 fyk = 25,0 kN/cm�
G zul,D = n � D zul 0,27 kN
Mustergasse 1 �zul = 10,0 kN/cm� Hd ,zul, N = Szul * m = 1,60 kN 32% � 67,7%
2
2700 Mustervillage �zul = 6,0 kN/cm� �( f � d) �
�v,zul = 14,6 kN/cm� � � �1 � w� � 1
� f �
vorh H d = 0,52 kN � min H d,zul = 1,60 kN 32%
date: 05.09.2007

vorh G = 0,18 kN � min G zul = 0,27 kN 67,7%

Eurofox - dimensioning Eurofox - dimensioning


05.09.2007 05.09.2007

results:
system: vertical supporting profile number of spans: 2
wind load: moment and deflection diagram
horizontal: wind: facadeweight:
centre distance: 0,60 m 1,00 m
-0,06
-0,06

-0,06

Verification of anchor profiles L 40/60/1,8

M zul = 0,137 kNm vertical:


0,00

0,00

0,00
0,00

0,00

W o = 0,305 cm�
W u = 1,373 cm� 0,00

E*I = 3,9760 kNm� 0,03 0,03


44 cm 107 cm 0 cm 44 cm
0 cm
system:
107 cm 0 cm

span: 2x 1,065 m
cantilever: k= 0,435 m
0,585 0,690
load: wind: 1,00 kN/m� 0,000
0,541 0,493
M Feld = 0,035 kNm � M zul = 0,137 kNm 25% facadeweight: 0,10 kN/m�

column: wind load: facade load: moment and deflection diagram

M St¸tz = 0,067 kNm � M zul = 0,137 kNm 49%


0,00
0,00

0,00

0,00

0,00

0,00

serviceability: 0,0027 0,00 0,00 0,00

0,6 0,6 0,6 0,6


4
max f= 0,128 *b * w * L / (E * I) = 0,77 mm
44 cm 107 cm 107 cm 0 cm
0 cm 44 cm

facade load:

0,000 0,000
0,000 0,000 0,000

0,0027

0,00 kN/m 0,00 kN/m 0,00 kN/m 0,00 kN/m profile: L-40/60/1,8 stress ratio: 65,17%

44 cm 107 cm 107 cm 0 cm 44 cm
support system: MacFox 40 load: H: 0,64 kN
V: 0,18 kN

EUROFOX installation training


■ We can provide your installation personnel with on-site instruction

www.eurofox.com

4 Changes reserved.

systemkat_07_VERS-E.indd 4 06.09.2007 17:22:29 Uhr


EUROFOX installation plans

www.eurofox.com

www.eurofoxengineering.com www.eurofox.com 5

systemkat_07_VERS-E.indd 5 06.09.2007 17:22:41 Uhr


Project-Checklist
Info from Date

Project name Project address

Area m2 New building Renovation

Facade Element
Metal Ceramic Fabricate
Compound/ACM Brick Dimension mm
HPL Render Weight kg/m2
Fibrecement Thickness mm

Fixing method EUROFOX-system


Visible Invisible Panel
Rivets Mechanical Portrait
Screws Adhesive Landscape

Project data
Building Height m1 Windloads Other
Storey Height m1 General kN/m2
Window Height m1 Special kN/m2

Wall condition
Concrete Other Certified pullout of anchor kN
Brick Insulation mm
Steel Cavity depth mm

CAD-Plans
View of claddings Plan view Arrangement of sheets Details

Client/Architect Installation company Dates


Name Name Planning

Address Address Offer

E-Mail E-Mail Installation

To provide you with an offer please complete and submit a project checklist, ideally accompanied with elevation and plan AutoCAD drawings, indicating your proposed
cladding requirements. This will allow us to prepare a project specific cladding solution, including static calculations, setting out information and overlay drawings for the
system and panels.

12 Changes reserved.

systemkat_07_VERS-E.indd 12 06.09.2007 17:22:52 Uhr


EUROFOX Engineering LTD
Unit 10 Blenheim Court
Brownfields - Welwyn Garden City
HERTS AL7 1AD
Tel: +44 (0)1707 333396, Fax: +44 (0)1707 333343
info@eurofoxengineering.com
Internet: www.eurofoxengineering.com

EUROFOX Vertriebsges.m.b.H.
A-2700 Wiener Neustadt, Eichbüchlergasse 18
Tel.: +43 (0)2622 69001-0, FAX: +43 (0)2622 69001-69
E-Mail: eurofox@eurofox.com