TIPO
NIVEL C-04 C-05 C-13 C-03 PL - 01 PL - 02 PL - 03 PL - 11 PL - 12
DIRECCIÓN GENERAL
EJES EJE1/EJE F EJE2/EJE F, EJE3/EJE F EJE 2/ EJE E,EJE 3/ EJE E EJE2/EJE D, EJE 3 / EJED EJE1 / EJE D EJE5 / EJE D EJE5 / EJE F EJE1 / EJE E EJE5 / EJE E
DE INFRAESTRUCTURA
bxt C-04( 0.25x0.50X0.50) C-05(0.25x0.50) C-13(0.25x0.50) C-03 (0.25x0.50) PL-01(0.25X1.25x1.50) PL-02(0.25X1.50x0.50) PL-03 (0.25X1.50x0.50) PL-11(0.25X1.00) PL-12(0.25X0.80)
PRIMER DIRECTOR GENERAL DE INFRAESTRUCTURA:
Ø 14 Ø 5/8" 10 Ø 3/4"+2 Ø 5/8" 12 Ø 5/8" 16 Ø 3/4"+2 Ø 5/8" 40Ø 5/8" 26Ø 5/8" 30Ø 5/8" 18Ø 5/8" 16Ø 5/8"
PISO
2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15
4 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25 3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25 3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25
3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25 3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25
Ing. Juan Carlos Sánchez Lazo
4 Ø 1/2" : 1@.05, c/extremo Rto. @ .20 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20
c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .15
3 Ø 3/8" 1@.05, c/extremo Rto. @ .20 2 Ø 3/8" 1@.05, c/extremo Rto. @ .20 2 Ø 3/8" 1@.05, c/extremo Rto. @ .20 DIRECTOR DE ESTUDIOS:
EXPEDE
I NTETÉCNC
I ODELPP
I VA
I BLE
PLANO LLAVE
PROLONG
. AV. CAYET
C-05 C-13 C-03
ANO HERE
bxt C-04 PL-04 C-04 C-04 PL - 11 PL - 12
DIA
SEGUNDO C-03(0.25x0.50)
Ø C -05(0.25x0.50) CL-04(0.25x0.50X50)
PISO C-04 (0.25x0.50X50) C-13(0.25x0.50) C-04(0.25x0.50X50) CL-04(0.25x0.50X50) PL-11(0.25X1.00) PL-12(0.25X0.80)
B-G
14 Ø 5/8" 10 Ø 3/4"+2 Ø 5/8" 12 Ø 5/8" 16 Ø 3/4"+2 Ø 5/8" 24Ø 5/8" 14 Ø 5/8" 14 Ø 5/8" 18Ø 5/8" 16Ø 5/8"
2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 3 Ø 3/8" 1@.05, 5@.10, 2@.15 c/extremo Rto. @ .25 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15 3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25 3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25
2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20
c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .15
1 Ø 3/8" 1@.05, c/extremo Rto. @ .20
EQUIPO TECNICO
Bach. ARQ° ELIZABETH PEREZ ALVAREZ
Bach. ING° MILCA PALACIN GRIJALVA
Bach. Ing. Sanit. JAIME ALEXANDER ROJAS LAZO
CADISTA MARIA SORIANO VILLACORTA
EVALUADOR:
CORTE
SC: 1/25
ESPECIALIDAD:
ESTRUCTURA
bxt C-08 C-02 C-08 C-08
SEGUNDO
Ø C-08 (0.25x0.50X50) C-02(0.25x0.50) C-08(0.25x0.50X50) C-08 (0.25x0.50X50)
PISO NOMBRE DEL PLANO:
14 Ø 5/8" 8 Ø 5/8" 14 Ø 5/8" 14 Ø 5/8"
2 Ø 3/8" 1@.05, 7@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 7@.10, 2@.15
c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25
CIMENTACION
CARACTERÍSTICA (S):
CORTE
SC: 1/25 CUADRO DE COLUMNAS Y
PLACAS
LÁMINA:
16005-CIM-3-002
bxt PL-7(0.25X0.50X1.75) C-02(0.25x0.50) PL-8(0.25X1.25X1.75) PL-9(0.25X0.50X1.25) C-01(0.25x0.50) C-02 (0.25x0.50) C-19(0.25x0.50) C-13(0.25x0.50) C-02(0.25x0.50)
PRIMER
Ø 34Ø 5/8" 8 Ø 5/8" 40Ø 5/8" 22 Ø 5/8" 10 Ø 5/8" 8 Ø 5/8" 4 Ø 3/4"+8 Ø 5/8" 12 Ø 5/8" 8 Ø 5/8"
DIRECCIÓN GENERAL
PISO
3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25 4 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25 3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25
DE INFRAESTRUCTURA
2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" : 1@.05, c/extremo Rto. @ .20 2 Ø 1/2 : 1@.05, c/extremo Rto. @ .20 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, c/extremo Rto. 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15
c/extremo Rto. @ .25 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20 c/extremo Rto. @ .25 c/extremo Rto. @ .25 @ .10 c/extremo Rto. @ .25 c/extremo Rto. @ .25 DIRECTOR GENERAL DE INFRAESTRUCTURA:
3 Ø 3/8" 1@.05, c/extremo Rto. @ .20 3 Ø 3/8" 1@.05, c/extremo Rto. @ .20 2 Ø 3/8" 1@.05, c/extremo Rto. @ .20
DIRECTOR DE ESTUDIOS:
CÓDG
I OSNP
I:
CUADRO DE COLUMNAS BLOQUE 04 350209
TIPO
NIVEL C-16 PL-14
EJE K/EJE 8, EJE K / EJE 11 PLANO LLAVE
EJE M/EJE 8, EJE M / EJE 11
ejes EJE L/EJE 8, EJE L / EJE 11
PROLONG
PRIMER
bxt C-15 C-02 C-01 PL - 9 C-02 C-02 C-19 C-02 C-02 PISO
Ø 6 Ø 5/8" 12 Ø 5/8"
. AV. CAYET
SEGUNDO C-15(0.25x0.50X50) PL-9(0.25X0.50X1.25)
Ø C-02(0.25x0.50) C-01(0.25x0.50) C-02( 0.25x0.50) C-02(0.25x0.50) C-19(0.25x0.50) C-02(0.25x0.50) C-02 (0.25x0.50) 1 Ø 3/8" 1@.05,7@.10, 2@.15
22 Ø 5/8" 1 Ø 3/8" 1@.05, 5@.10, 2@.15
ANO HERE
PISO 12 Ø 5/8"
c/extremo Rto. @ .25
8 Ø 5/8" 10 Ø 5/8" 8 Ø 5/8" 8 Ø 5/8" 4 Ø 3/4"+8 Ø 5/8" 8 Ø 5/8" 8 Ø 5/8" c/extremo Rto. @ .25
3 Ø 3/8" 1@.05, 5@.10, 2@.15 c/extremo Rto. @ .25 4 Ø 3/8" : 1@.05, c/extremo Rto. @ .20
DIA
2 Ø 3/8" 1@.05, 7@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, c/extremo Rto. 2 Ø 3/8" 1@.05, 5@.10, 2@.15 2 Ø 3/8" 1@.05, 5@.10, 2@.15
c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25
2 Ø 1/2" : 1@.05, c/extremo Rto. @ .20
c/extremo Rto. @ .25 c/extremo Rto. @ .25 @ .10 c/extremo Rto. @ .25 c/extremo Rto. @ .25
B-G
2 Ø 3/8" 1@.05, c/extremo Rto. @ .20
CORTE
RESPONSABLES DEL PROYECTO:
CORTE SC: 1/25 COORDINADOR DEL PROYECTO:
Arqº YULINA VENEGAS LOPEZ CAP 9595
SC: 1/25
RESPONSABLE DEL DISEÑO ARQUITECTONICO:
Arqº JOSE TURPO RAMOS CAP 9381
RESPONSABLE DEL DISEÑO ESTRUCTURAL:
Ingº JAIME FLORES QUINCHO CIP 111819
EQUIPO TECNICO
Bach. ARQ° ELIZABETH PEREZ ALVAREZ
CORTE Bach. ING° MILCA PALACIN GRIJALVA
Bach. Ing. Sanit. JAIME ALEXANDER ROJAS LAZO
SC: 1/25 CADISTA MARIA SORIANO VILLACORTA
TIPO
NIVEL C-02 C-02 C-14 PL - 10 C-15
ejes EJE6/EJE H, EJE11/EJE H EJE 8/EJE H EJE 6 / EJE J EJE 11 / EJE J
EJE 8 / EJE J
EJE6/EJE I, EJE 11/EJE I EJE 8/EJE I
bxt C-02(0.25x0.50) C-02(0.25x0.50) C-14( 0.25x0.50X50) PL-10(0.25X0.50X1.50) C-15( 0.25x0.50X50)
PRIMER
Ø 8 Ø 5/8" 8 Ø 5/8" 12 Ø 5/8" 3 4Ø 5/8" 12 Ø 5/8"
PISO COORDINADOR DE EVALUACIÓN:
3 Ø 3/8" 1@.05, 6@.10, 2@.15 c/extremo Rto. @ .25
2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 3/8" 1@.05, 6@.10, 2@.15 2 Ø 1/2" : 1@.05, c/extremo Rto. @ .15 2 Ø 3/8" 1@.05, 6@.10, 2@.15
c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25 3 Ø 3/8" 1@.05, c/extremo Rto. @ .20 c/extremo Rto. @ .25
TIPO
CORTE NIVEL C-16 C-16 C-18 PL-14 PL-14
SC: 1/25 ejes EJE O/ EJE 7, EJE O/ EJE 10 EJE N/ EJE 4 EJE N/ EJE 7 EJE O/ EJE 4 EJE N/ EJE 10
bxt C-16 (0.25x0.40) C-16( 0.25x0.40) C-18 (0.25x0.70) PL-14 (0.25x0.50X0.50) PL-14 ( 0.25x0.50x0.50)
PRIMER
Ø 6 Ø 5/8" 6 Ø 5/8" 10 Ø 5/8" 12 Ø 5/8" 12 Ø 5/8"
PISO
1 Ø 3/8" 1@.05,6@.10, 2@.15 1 Ø 3/8" 1@.05,7@.10, 2@.15
1 Ø 3/8" 1@.05, 6@.10, 2@.15 1 Ø 3/8" 1@.05, 7@.10, 2@.15 1 Ø 3/8" 1@.05, 7@.10, 2@.15
c/extremo Rto. @ .25 c/extremo Rto. @ .25 ESPECIALIDAD:
c/extremo Rto. @ .25 c/extremo Rto. @ .25 c/extremo Rto. @ .25
4 Ø 3/8" : 1@.05, c/extremo Rto. @ .20 4 Ø 3/8" : 1@.05, c/extremo Rto. @ .20
ESTRUCTURA
CORTE
SC: 1/25
CUADRO DE COLUMNAS Y
PLACAS
CORTE
SC: 1/25 LÁMINA:
16005-CIM-3-003
PROLONG
C-16
C-16
. AV. CAYET
ANO HERE
PL-10 C-15
C-14
DIA
B-G
- FACTOR DE ZONA (ZONA2): Z=0.45 - FACTOR DE ZONA (ZONA2): Z=0.45 - FACTOR DE ZONA (ZONA2): Z=0.45
- FACTOR DE USO E IMPORTANCIA U = 1.5 - FACTOR DE USO E IMPORTANCIA U = 1.5 - FACTOR DE USO E IMPORTANCIA U = 1.5
- FACTOR DE SUELO (TIPO S3): S=1.1 Tp(s)=1.0 s. - FACTOR DE SUELO (TIPO S3): S=1.1 Tp(s)=1.0 s. - FACTOR DE SUELO (TIPO S3): S=1.1 Tp(s)=1.0 s.
NPT= +0.45m - COEFICIENTE DE AMPLIFICACION SISMICA: C = 2.5 - COEFICIENTE DE AMPLIFICACION SISMICA: C = 2.5 - COEFICIENTE DE AMPLIFICACION SISMICA: C = 2.5
NFC= -1.68m - FACTOR DE REDUCCION EN EJE "X" : R = 7 - FACTOR DE REDUCCION EN EJE "X" : R = 7 - FACTOR DE REDUCCION EN EJE "X" : R = 7
DROP e =0.65 m - FACTOR DE REDUCCION EN EJE "Y" : R = 7 - FACTOR DE REDUCCION EN EJE "Y" : R = 7 - FACTOR DE REDUCCION EN EJE "Y" : R = 7 RESPONSABLES DEL PROYECTO:
COORDINADOR DEL PROYECTO:
C-02 NPT= +0.45m C-02 TIPO A2 (Edificación Esencial: Comisaria) Arqº YULINA VENEGAS LOPEZ CAP 9595
NFC= -1.68m
TIPO A2 (Edificación Esencial: Comisaria) TIPO A2 (Edificación Esencial: Comisaria) RESPONSABLE DEL DISEÑO ARQUITECTONICO:
C-02 Arqº JOSE TURPO RAMOS CAP 9381
Sentido X: SISTEMA DUAL
RESPONSABLE DEL DISEÑO ESTRUCTURAL:
Sentido Y: SISTEMA DUAL Sentido X: SISTEMA DUAL Sentido X: SISTEMA DUAL Ingº JAIME FLORES QUINCHO CIP 111819
Sentido Y: SISTEMA DUAL Sentido Y: SISTEMA DUAL
RESPONSABLE DE INSTALACIONES SANITARIAS
PARAMETROS PARA DESPLAZAMIENTO LATERAL Ingº LUIS A. DE LA CRUZ MARTINEZ CIP 137691
DROP e =0.65 m
EQUIPO TECNICO
Bach. ARQ° ELIZABETH PEREZ ALVAREZ
DROP e =0.65 m Bach. ING° MILCA PALACIN GRIJALVA
DROP e =0.65 m Bach. Ing. Sanit. JAIME ALEXANDER ROJAS LAZO
CADISTA MARIA SORIANO VILLACORTA
C-19 C-13 C-02
LOSA DE CIMENTACION e = 0.40 m
C-04 C-05 C-05 PL-03 NPT= +0.45m
NFC= -1.68m
COORDINADOR DEL PROYECTO:
- FACTOR DE ZONA (ZONA2): Z=0.45
- FACTOR DE USO E IMPORTANCIA U = 1.5
LOSA DE CIMENTACION e = 0.40 m - FACTOR DE SUELO (TIPO S3): S=1.1 Tp(s)=1.0 s. NPT + 0.45
- COEFICIENTE DE AMPLIFICACION SISMICA: C = 2.5 NFP + 0.40 NFP + 0.40 NPT + 0.45
- FACTOR DE REDUCCION EN EJE "X" : R = 7
- FACTOR DE REDUCCION EN EJE "Y" : R = 7 AFIRMADO AFIRMADO
RELLENO CON MATERAIL DE PRESTAMO COMPACTADO NTN RELLENO CON MATERAIL DE PRESTAMO COMPACTADO NTN
DROP e =0.65 m DROP e =0.65 m
DROP e =0.65 m
AL 95% DE MDS DEL ENSAYO DE PROCTOR MODIFICADO
ESPECIALISTA:
AL 95% DE MDS DEL ENSAYO DE PROCTOR MODIFICADO
BLOQUE 01 C-01
TIPO A2 (Edificación Esencial: Comisaria)
CORTE DE TERRENO Y RELLENO CON MATERIAL DE PRESTAMO CORTE DE TERRENO Y RELLENO CON MATERIAL DE PRESTAMO
NPT= +0.45m COMPACTADO AL 95% DE MDS DEL ENSAYO DE PROCTOR MODIFICADO COMPACTADO AL 95% DE MDS DEL ENSAYO DE PROCTOR MODIFICADO
NFC= -1.68m C-13 C-13 PL-12 PL-9 C-02
PL-11 Sentido X: SISTEMA DUAL Ø 5/8"@0.25 Ø 5/8"@0.125
DROP e =0.65 m
Sentido Y: SISTEMA DUAL
DROP e =0.65 m
LOSA DE CIMENTACION e = 0.40 m
DROP e =0.65 m EVALUADOR:
DROP e =0.65 m
PL-02 PL-07 C-02 PL-08
PL-01 PL-15
C-03 C-03 NPT= +0.45m C-08 PL-04
NFC= -1.68m C-02
LOSA DE CIMENTACION e = 0.40 m
ESPECIALIDAD:
AFIRMADO
sobrecimiento f'c 175 kg/cm2
NPT + 0.45
sobrecimiento
f'c 175 kg/cm2
Ø 3/8"@0.20
ESTRUCTURA
NTN
RELLENO CON MATERAIL DE PRESTAMO COMPACTADO
NPT + 0.15
AL 95% DE MDS DEL ENSAYO DE PROCTOR MODIFICADO Afirmado