Technical Manual of AUX Air Conditioner

CONTENTS

Product Specification.………………..…………………...1

Refrigeration Diagram……………………………….…....3

Introductions of Installation………………….……………6

Remote Controller Introductions……………….……….13

Brief Introduction for Usage…………………..………….21

Wiring Diagram……………………………..……………..27

Troubleshooting Guide……………………………………31

Exploded Views & Parts List……………………………..48

I
Technical Manual of AUX Air Conditioner

Chapter 1 Product Specification


1.1 Photo of Product

Indoor Unit For KP

Outdoor Unit

Reminder: All views here are for reference only, Specifications are subject

to the physical product.


1
Technical Manual of AUX Air Conditioner

1.2 Outline

Indoor Unit

MODEL 9000BTU 12000BTU 18000BTU 24000BTU


W mm 680 750 880 1080
D mm 185 185 208 232

H mm 255 255 280 300

Dimensions

Outdoor Unit

MODEL 9000BTU 12000BTU 18000BTU 24000BTU


W mm 663 700 760 800

D mm 254 225 260 300

H mm 421 500 540 590

2
Technical Manual of AUX Air Conditioner

Chapter 2 Refrigeration Diagrams


2.1 Cooling Only

Cooling Mode

Cooling Cycle
Steam-gas of low pressure
Indoor heat exchanger Compressor
(Evaporation) (Compression)

Liquid of low pressure Gas of high pressure


(also a little gas) & temperature

Super cooled liquid


of high pressure
Capillary Outdoor heat exchanger
(Throttling) (Condensation)
3
Technical Manual of AUX Air Conditioner

2.2 Cooling & Heating


Cooling Mode

Cooling Cycle
Indoor heat exchanger Steam-gas of low pressure Compressor
(Evaporation) (Compression)

4-way valve
Liquid of low pressure
(Heat pump only)
(also a little gas)
Gas of high
pressure &
Super cooled liquid temperature
Capillary of high pressure Outdoor heat exchanger
(Throttling) (Condensation)

4
Technical Manual of AUX Air Conditioner

Heating Mode

Heating Cycle
Gas of high
Indoor heat exchanger Pressure & temperature Compressor
(Condensation) (Compression)

4-way valve
(Heat pump only)
Super cooled liquid of low pressure

Steam-gas of
low pressure
Super cooled liquid
of high pressure
Capillary Outdoor heat exchanger
(Throttling) (Evaporation)

5
Chapter 3 Instructions of Installation

SPLIT TYPE WALL MOUNTED AIR-CONDITIONER INSTALLATION INSTRUCTIONS


The Installation Instructions is used to Split type wall mounted air-conditioner installation .

6
The distance between indoor and outdoor unit should be 5 meters and pipe length can
go up to maximum 15 meters with additional refrigerant charge.

Max. Allowable Limit of Tubing Limit of Elevation Requires Amount


Tubing Length at Length(m) Difference H(m) of Additional
Shipment(m) Refrigerant (g/m)
CC 12000Btu CC 18000Btu

5 15 5 20 30

7
10
Technical Manual of AUX Room Air Conditioner

Expelling the air: humid air in the Outdoor unit


refrigerating system might cause trouble
of compressor.
Take off the cover from the stop valve
and T-branch valve.
Take off the auxiliary cover from the
T-branch valve.
Turn the stop valve rod anti-clock wise
to an angle of 90 degree, keep it open
for 8 seconds and close the valve. To indoor unit
Liquid side
Check whether there is air leakage at Vapor side Gas side
all connection parts of pipes.
Push the top rod of T-branch valve by Stop valve(open)
hexagon wrench to expel air.
Repeat the third and fifth steps. Cover
Open the stop and T-branch valve with
a hexagon wrench to make the unit
operate.
There is no leakage allowed, please
check all the piping connection parts. T-branch valve(open)
You must test the leakage, generally, Auxiliary cover Hexagon wrench
it can be tested by soap water.
If the A/C is filled with R410a, make sure to discharge air and moisture
remaining in the refrigerant system with a vacuum pump.
(For method of using a manifold valve, refer to its operation manual.)
1.completely tighten the flare nuts, A, B, C, D, connect the manifold valve charge
hose to a charge port of the low-pressure valve on the gas pipe side.
2.Connect the charge hose connection to the vacuum pump.
3.Fully open the handle Lo of the manifold valve.
4.Operate the vacuum pump to evacuate. After starting evacuation, slightly loose
the flare mut of the Lo valve on the gas pipe side and check that the air is entering
(Operation noise of the vacuum pump changes and a compound meter indicates
0 instead of minus.)
Refrigerant
5.After the evacuation is complete, fully Outdoor
Indoor
unit
close the handle Lo of the manifold valve unit A Gas side C
and stop the operation of the vacuum
Liquid side D
pump. Make evacuation for 15 minutes or
B
more and check that compound meter Packed valve Half union
5
indicates -76cmHg(-1 10 Pa).
Manifold valve
6.turn the stem of the packed valve B about
Compound meter Pressure gauge
45 counterclockwise for 6~7 seconds
-76cmHg
after the gas coming out, then tighten the
flare nut again. Make suer the pressure
display in the pressure indicator is a little
Handle Hi
higher than the atmosphere pressure.
Handle Lo
7.Remove the charge hose from the Low Charge hose
pressure charge hose. Charge hose Vacuum pump
8.Fully open the packed valve stems B
and A.
9.Securely tighten the cap of the packed
valve.
Low pressure valve

11
Technical Manual of AUX Room Air Conditioner

Unscrew the screw, take off the control panel cover from the unit.
Connect the cable to their terminals according to their number.
The grounded wire connection:
1.loosen the grounded screw of electrical shelf.
2.Connect the grounded wire with the grounded screw then setscrew in the mark
formerly.
Fix the cable to the terminal board with fastening piece.
Reinstall the cover with the screw.

NOTE: Terminal board

Don't reverse the power polarity. Cover

The wrong connection lead to the mal


function of some electrical parts.
Must fix the screwnail of the firmly wire, Grounded wire
More than 5mm

then drag the wire lightly, confirmation

Interconnection cord
Electrical Shelf

whether it's firmly. Fastener for cable


connection
Must changed if the wire slide, the self-drive
screw can't used to the electric connection.
If there is a connector, connect it directly.
Heat-pump type
Terminal board for outdoor unit Terminal board for outdoor unit

Temperature control wire connector Compressor signal wire connector


(only for heat pump type) (only for cooling pump type
6000W/7000W)

Compressor signal wire connector and


temperature control wire connector
(only for heat pump type 6000W/7000W) Note:
Explanation for the power cord without
plug (see below figure):

Brown= Live wire


and
Blue= Zero line
Yellow/Green= Grounded wire

Single wire Double wires

12
AIR-CONDITIONER REMOTE
CONTROLLER INSTRUCTIONS

SET TEMPERATURE( )
AUTO FAN
COOL HIGH
DRY MID
HEAT LOW

ON/OFF

SET

MODE CLEAN SPEED

SLEEP FRESH STRONG

SWING DUST FEELING

HEALTH FUNGUSPROOF SCREEN TIMER

Read this instructions carefully so that


you can use the air-conditioner safely and
correctly.
Take good care of the instructions so
that it can be referred to at any time.
13
Buttons description
LCD displays instruction
SET TEMPERATURE( ) TRANSMIT DIGITAL ON/OFF

AUTO FAN SET ROOM RUNNING


COOL HIGH MODE
DRY MID RUNNING
MODE SPEED
HEAT LOW
TIMER ON OFF
ON/OFF
TIMER FEELING
9 SET 1
ON/OFF display:
10 2 when the remote controller is
MODE CLEAN SPEED
11 3
the on state, the LCD will be
SLEEP FRESH STRONG displays otherwise will not be
12 4 display.
SWING DUST FEELING Digital display:
13 5
6
Under the state of normal
HEALTH FUNGUSPROOF SCREEN TIMER
working. It displays set
14 7
temperature, while the feeling
function is start. It will displays
15 8 room temperature, and under
the state of timer mode. It will
displays set timer.

1. ON/OFF button
You can start the air-conditioner by pressing this button and stop its
operation by pressing it again.
2. FRESH button
This button is invalidation.
3. SPEED button
You can select fan speed show as the follow:

Low Med High Auto

4. STRONG button
Only under the state of cooling or heating mode, press this button, the fan speed is
adjusted to strong auto-maticlly and the LCD displays high fan , the strong
function is started to reach the highest cooling or heating.

14
5. FEELING button
When it displays FEELING button:
Press this button can be used to set the feeling function. The LCD shows
the actual room temperature when the function set and it shows the setting
temperature when the function cancelled. This function is invalid when the
appliance at the Fan mode.
6. DUST button
This button is invalidation.
7. TIMER button
Setting the ON timer time
a. When remote controller is at off state, press TIMER button, the LCD displays
TIMER ON and the timer time, the range of setting time is 0.5h to 24h.
b. You can press the or button to adjust the timer time, each touch will
be set time to increase or reduce 0.5h before 10 hours ago, after ten hours will be
set time to increase or reduce 1h per pressing, to enables your required timer.
c. Press TIMER button again, to set the timer on function.
d. You can set another function to insure the suitable state after air conditioner turn
on (including mode, temperature, swing, fan speed and etc). The LCD will displays
all your setting and keep it, when the timer reach to the set time, the air conditioner
will be working according to your set automatically.
Setting the OFF timer time
a. When remote controller is at on state, press TIMER button, the LCD displays
TIMER OFF and the timer time, the range of setting time is 0.5h to 24h.
b. You can press the or button to adjust the timer time, each touch will
be set time to increase or reduce 0.5h before 10 hours ago, after ten hours will be
set time to increase or reduce 1h per pressing, to enables your required timer.
c. Press TIMER button again, to set the timer off function.

8. SCREEN button
You can let the LCD displays working or not by pressing this button.

9. or button
Press the + or - button,you can set the temperature range from 16 to
32 ,Display will change as you touch the button.
10. CLEAN button
a. When remote controller is at the off state, press clean button, the wind
guiding bars turn to initial postions for cooling, the A/C runs clean function
with max duration 35mins.The purpose of its function is to clean dust on evapo
rator and dry the inside water of evaporator and to prevent the evaporator going
moldy due to water deposition and boasting strange smell.
b. After setting clean function, press clean button again to cancel clean
function or press ON/OFF button to cancel clean function and start A/C.
c. The clean function will be no working after 35 minutes running working without
any operation.

15
Note: clean function can be set in parallel with time start function;
in this case , time start function will be executed after clean function.
11. MODE button
Which enables you to select different operation mode,after each pressing, the
operation mode will be changed. It shows in the following display.
AUTO COOL DRY HEAT FAN AUTO
Remark: cold wind type has no heating function.
12. SLEEP button
1.press the SLEEP button, the sleeping indicator light of indoor unit flashes on.
2.after the setting of sleeping mode, the cooling operation enables the set te
mperature to increase 1 after 1hour and another 1 automatically after 1 hour.
3.after the setting of sleeping mode, the heating operation enables the set
temperature to drop 2 after 1hour and another 2 automatically after 1 hour.
4.the air-conditioner runs in sleeping mode for 7 hours and stops automatically.
Remark: press the MODE or ON/OFF button, the remote controller clears
sleeping mode away.
13. SWING button
Press this button, the horizontal wind direction vanes can rotate automatically,
when you have the desired vertical wind direction, press it again, the horizontal
wind direction vanes will be stopped at the situation of your choice.
14. HEALTH button
Press this button, you can turn on or off the health function.
15. FUNGUSPROOF button
This A/C has special dry and anti-mold function which has yes or no
two selections. This function is controlled by the remote controller under cooling,
dry and auto (cooling and dry) modes, the horizontal wind guiding bars are at the
initial position for cooling. The A/C runs under heating mode(the cooling only A/C
only runs under fan mode), the internal fan runs for three minutes with weak wind
before stop. The purpose of this function is to dry the inside of the evaporator and
to prevent the evaporator from going mouldy due to water deposition and thus disp
ersing strange smell.
Note:
1.This function has not been set in the factory. You may freely set and cancel
this function. The setting method is: under off status of the A/C and the re
mote controller, point the remote controller toward the A/C and continuously
press FUNGUSPROOF pushbutton for one time, the buzzer keep beeps five
times again after five times beeps, indicating that this function is ready. In case
this function has been set, unless the whole A/C is powered off or the function is
manually cancelled, the A/C then has this function as a default;
2.To cancel the function: 1. Power off the whole A/C; 2. Under off status of
theA/C and the remote controller, point the remote controller toward the A/C
and continuously press FUNGUSPROOF pushbutton for one time, the buzzer
keep beeps three times again after five times beeps, indicating that this function
has been cancelled;
3.When this function is on, it is suggested not to restart the A/C before it is co
mpletely stop;
4.This function will not run in case of time stop or sleep stop.

16
Usage
Fix batteries

1.Slide open the cover according the direction indicated by arrowhead.


2.Put into two brand new batteries (7#), position the batteries to right electric
poles (+ -).
3.Put back the cover.

Automatic operation mode


1.Press the MODE button, select the automatic operation mode.
2.Press the SPEED button, you can select fan speed.You can select fan
speed from LOW, MID, HIGH, AUTO.
3.Press the ON/OFF button, the operation indicator is on, the air-conditioner
starts to operate the automatic mode.Press the button again, the air-conditioner
stops.
Cooling/Heating operation mode
(cold wind type has no heating function)
1.Press the MODE button, select the Cooling or Heating operation mode.
2.Press the or button, set the temperature, temperature can
be set at 1 difference range from 16-32 .
3.Press the SPEED button, you can select fan speed.You can select fan speed
from LOW, MID, HIGH, AUTO.
4.Press the ON/OFF button, the operation indicator is on, the air-conditioner starts
to operate the automatic mode.Press the button again, the air-conditioner stops.
Fan operation mode
1.Press the MODE button, select the Cooling or Heating operation mode.
2.Press the SPEED button, you can select fan speed.You can select fan speed
from LOW, MID, HIGH.
3.Press the ON/OFF button, the operation indicator is on, the air-conditioner
starts to operate the automatic mode.Press the button again, the air-conditio
ner stops.
Remark: In the circulation operation mode, to set the temperature is
noneffective.

Drying operation mode


1.Press the MODE button, select the Dry operation mode.
2.Press the or button, set the temperature, temperature can be set
at 1 difference range from 16-32 .
3.Press the SPEED button, you can select fan speed.You can select fan speed
from LOW, MID, HIGH, AUTO.
4.Press the ON/OFF button, the operation indicator is on, the air-conditioner starts
to operate the automatic mode.Press the button again, the air-conditioner stops.
17
Night Luminous Function of Remote Controller(Only the rem
ote controller with this function can be used)
For your convenient use of the remote controller in the darkness without any
lighting, this remote controller has blue background light and luminous pushbuttons.
Function at you press on any of the pushbutton, the background light will immediately
release soft light so that you are easy to operate the remote controller. If you do not
operate the controller within 10 seconds, the background light will automatically
disappear.
Note:
All the figures above are the displays after being initially electrified or
re-electrified after power off. In actual operations, the remote controller
screen displays related items only.
Attention
1.Aim the remote controller towards the receiver on the air-conditioner.
2.The remote controller should be within 8 meters away from the receiver.
3.No obstacles between the remote controller and receiver.
4.Do not drop or throw the remote controller.
5.Do not put the remote controller under the forceful sunrays or heating facilities
and other heating sources.
6.Use two 7# batteries, do not use the electric batteries.
7.Take the batteries out of remote controller before stop its using for long.
8.When the noise of transmitting signal can t be heard indoor unit or the transmission
symbol on the display screen doesn t flare, batteries need be replaced.
9.If reset phenomenon occurs on pressing the button of the remote controller, the
electric quantity is deficient and new batteries need to be substituted.
10.The waste battery should be disposed properly.

18
19
20
Chapter 5 Brief Introduction for Usage

21
22
23
24
25
26
Technical Manual of AUX Air Conditioner

Chapter 6 Wiring Diagram


6.1 Electric chart for 09/12/18K/12K(115V)(Non inverter)

Indoor unit

27
Technical Manual of AUX Air Conditioner

Outdoor unit

28
Technical Manual of AUX Air Conditioner

6.2 Electric chart for 24K(Non inverter)

Indoor unit

29
Technical Manual of AUX Air Conditioner

Outdoor unit

30
Technical Manual of AUX Air Conditioner

Chapter 7 Troubleshooting Guide

7.1 Error Code


No. Error Code Problem

1 E1 Temperature sensor of air intake fault

2 E2 Temperature sensor of outdoor coil fault

3 E3 Temperature sensor of indoor coil fault

4 E4 PG motor of indoor unit feedback fault

7.2 Troubleshooting Guide for 09-12K


1. The Foremost Inspecting Items
ŁThe input voltage must be within +10% tolerance of the rated Voltage. If it

is not the case, the air-conditioner will probably not work normally.

łCheck the connecting cord between indoor unit and outdoor unit to see if

it is properly connected. The connecting must be done according to the

wiring diagram, please also notice that even different models may have the

connecting cord of the same specification.

Please check if the marks at the connecting terminal and the marks on the

cord can match, otherwise, the air-conditioner will not work normally.

ŃIf the following phenomena are found, the problem is not from the

air-conditioner itself.
31
Technical Manual of AUX Air Conditioner

NO. Problems Causes


Since the air-conditioner is powered on, it
The motor is heard operating but the
will come to working condition as long as you
1 air-conditioner dose not work when
press the ON/OFF button of the remote
the indoor unit is powered on
control and the Signal is well received.
The compressor stops running but If you turn off the air-conditioner and restart it
the indoor fan motor keeps working immediately, it will return to normal in 3
2 when it is at cooling mode with the minutes, after that, the air-conditioner will
indoor temperature higher than set automatically adjust the indoor fan speed to
temperature. what you set.
The compressor works The air-conditioner will automatically control
3 discontinuously at dehumidifying the working of the compressor according to
mode. the inside temperature
The TIMER is set with the air-conditioner; it
The air-conditioner does not work will be in hold on condition. If the TIMER
4
while the LED display is on. setting is cancelled, the air-conditioner will
return to normal working condition
The compressor works
The compressor stops internally or the fan
discontinuously at cooling and
5 motor slows down to prevent the indoor heat
dehumidifying mode, and the indoor
exchanger from being frozen.
fan motor slows down.

32
Technical Manual of AUX Air Conditioner

2. No Power Display
ŁItems

a) Check if the input voltage is correct?

b) Check if the AC power supply connecting is correct?

c) Check if the output voltage of the manostat L7805 (IC2) is correct?

łTrouble shooting procedure

33
Technical Manual of AUX Air Conditioner

3. The Indoor Fan Motor Does Not Work


ŁItems

a) Check if the indoor fan motor is connected correctly to the connector (CN8)?

b) Check if the AC input voltage is correct?

c) Check if the IC of indoor fan motor is connected correctly to the connector

(CN2)?

d) Check if the capacity of indoor fan motor is connected correctly to the

connector (CN8)?

łTrouble shooting procedure

34
Technical Manual of AUX Air Conditioner

4. The Outdoor Unit Does Not Work


ŁItems

a) Check if the input voltage is correct?

b) Check if the wire connection of the outdoor connecting terminal is correct?

łTrouble shooting procedure

35
Technical Manual of AUX Air Conditioner

5. The Step Motor Does Not Work


ŁItems

a) Check if the input voltage is correct?

b) Check if the step motor controlling the up-down movement firmly

connected to Cn2?

łTrouble shooting procedure

36
Technical Manual of AUX Air Conditioner

6. Heating Mode Can Work, But No Hot Air Blow


ŁCheck if the set temperature is lower than the indoor temperature?

łCheck if the indoor PCB is connected to the terminal correctly?

37
Technical Manual of AUX Air Conditioner

7. Remote Control Can Not Work


Trouble shooting procedure

38
Technical Manual of AUX Air Conditioner

8. The Failure Analysis of the Main Parts

39
Technical Manual of AUX Air Conditioner

7.3 Troubleshooting Guide for 18-36K


1. The Foremost Inspecting Items
ŁThe input voltage must be within +10% tolerance of the rated Voltage. If it

is not the case, the air-conditioner will probably not work normally.

łCheck the connecting cord between indoor unit and outdoor unit to see if

it is properly connected. The connecting must be done according to the

wiring diagram, please also notice that even different models may have the

connecting cord of the same specification.

Please check if the marks at the connecting terminal and the marks on the

cord can match, otherwise, the air-conditioner will not work normally.

ŃIf the following phenomena are found, the problem is not from the

air-conditioner itself.

NO. Problems Causes


Since the air-conditioner is powered on, it will come to
The motor is heard operating but the
working condition as long as you press the ON/OFF
1 air-conditioner dose not work when the
button of the remote control and the signal is well
indoor unit is powered on
received.
The compressor stops running but the indoor If you turn off the air-conditioner and restart it
fan motor keeps working when it is at cooling immediately, it will return to normal in 3 minutes, after
2
mode with the indoor temperature higher that, the air-conditioner will automatically adjust the
than set temperature. indoor fan speed to what you set.
The air-conditioner will automatically control the
The compressor works discontinuously at
3 working of the compressor according to the inside
dehumidifying mode.
temperature
The TIMER is set with the air-conditioner; it will be in
The air-conditioner does not work while the
4 hold on condition. If the TIMER setting is cancelled, the
LED display is on.
air-conditioner will return to normal working condition.
The compressor works discontinuously at The compressor stops internally or the fan motor slows
5 cooling and dehumidifying mode, and the down to prevent the indoor heat exchanger from being
indoor fan motor slows down. frozen.
40
Technical Manual of AUX Air Conditioner

2. No Power Display
ŁItems

ķCheck if the input voltage is correct?

ĸCheck if the AC power supply connecting is correct?

ĹCheck if the output voltage of the manostat L7805(IC2)is correct?

łTrouble shooting procedure

41
Technical Manual of AUX Air Conditioner

3. The Indoor Fan Motor Does Not Work


ŁItems

ķCheck if the indoor fan motor is connected correctly to the connector(CN8)?

ĸCheck if the AC input voltage is correct?

Ĺ Check if the IC of indoor fan motor is connected correctly to the

connector(CN2)?

ĺCheck if the capacity of indoor fan motor is connected correctly to the

connector(CN8)?

łTrouble shooting procedure

42
Technical Manual of AUX Air Conditioner

4. The Outdoor Unit Does Not Work


ŁItems

ķCheck if the input voltage is correct?

ĸCheck if the wire connection of the outdoor connecting terminal is correct?

łTrouble shooting procedure

43
Technical Manual of AUX Air Conditioner

5. The Step Motor Does Not Work


ŁItems

ķCheck if the input voltage is correct?

ĸCheck if the step motor controlling the up-down movement firmly connected

to Cn2?

łTrouble shooting procedure

44
Technical Manual of AUX Air Conditioner

6. Heating Mode Can Work, But No Hot Air Blow


ŁCheck if the set temperature is lower than the indoor temperature?

łCheck if the indoor PCB is connected to the terminal correctly?

45
Technical Manual of AUX Air Conditioner

7. Remote Control Can Not Work


Trouble shooting procedure

46
Technical Manual of AUX Air Conditioner

8. The Failure Analysis of the Main Parts

47
Technical Manual of AUX Air Conditioner

Chapter 8 Exploded Views & Parts List


8.1 P
Indoor unit for PAC9041/P AC12041 041

48
Technical Manual of AUX Air Conditioner

Parts List of Indoor unit for PAC9041


Exploded
Chinese Name Name Pcs Remark
View No
1 䴶ᵓ Panel 1
2 ᰒ⼎♃ᵓ㒘ӊ Display board 1
3 ᰒ⼎♃ᑻ Indication lamp holder 1
4 䴭⬉䰸ᇬ఼ Electrostatic precipitator 1
5 ᴔ㦠㔥 Sterilization filter 1
6 䖛Ⓒ㔥㒘ӊ Filter 2
7 ЁḚ㶎䩝Ⲫ In box screw cap 3
8 ᇐ亢䮼 Horizontal air-blade 1
9 ЁḚⲪ Cover of medium frame 1
10 䴶ᵓवষ Panel clasper 1
11 䴶ᵓᬃᩥᴚ Stand bar 2
12 ЁḚ Medium frame 1
13 䩶ϱ㔥㔽 Wire mesh enclosure 1
14 䕈༫ sleeve 1
15 ℹ䖯⬉ᴎ Step motor 1
16 ᇐ亢ᶊ Air-vent holder 1
17 ᇐ亢৊⠛ Vertical air-blade 2
18 ᇐ亢৊⠛ᠬᵓ Bracket of airflow vanes 1
19 㪌থ఼㒘ӊ Evaporator assembly 1
20 䌃⌕亢৊ Cross flow fan 1
21 ⬉ᴎ Fan motor 1
22 ⬉ᴎय़Ⲫ Motor cover 1
23 䋳⾏ᄤ Negative ion 1
24 ᑩᑻ Chassis 1
25 ᣖᵓ㒘ӊ Mounting plate 1
26 㪌থ఼Ꮊᬃᶊ Left plastic-crutch for evaporator 1
27 ‵㛊䕈ᡓᑻ Bearing holder for indoor fan 1
28 ⬉᥻ⲦⲪ Cover of controller box 1
29 ⬉⑤㒓ᢅ᫔ Power supply clamp 1
30 ⬉⑤䖲᥹㒓य़ᵓ Connection cable clamp 1
31 ッᄤᵓ Terminal board 1
32 Џ᥻ᵓ Main PCB 1
33 ⬉᥻Ⲧ Controller box 1
34 বय़఼ Transformer 1
35 ⬉⑤㒓 Power supply 1
36 ⬉⑤䖲᥹㒓 Connection cable 1

49
Technical Manual of AUX Air Conditioner

8.2.1 Outdoor unit for PAC9041

50
Technical Manual of AUX Air Conditioner

Parts List of Outdoor unit for PAC9041


Exploded
Chinese Name Name Pcs Remarks
View No
 ⬉఼Ⲫᵓ Electric cover 

 েջᵓ Right side plate 

 ៾ℶ䯔 Gas valve assembly 

 ៾ℶ䯔  Liquid valve assembly 

 䯔ᵓ Valve plate 

 ᑩⲬ Chassis assembly 

 েᑩ㛮 right footing  

 ⋉㛮㶎ᷧ Pump bolt 

 Ꮊᑩ㛮 left footing 

 ‵㛊‫ޣ‬䳛ൿ rubber cushion 

 य़㓽ᴎ Compressor assembly 

 ໻ൿ೜ Big washer 

 ݁㾦㶎↡ Hexagonal nut 

 䴶ᵓ㔥㔽 Front net 

 䴶ᵓ Panel 

 ݁㾦㶎↡ Hexagonal nut 

 䕏ൟᔍㇻൿ೜ Light spring washer 

 ᅸ໪亢৊˄䕈⌕˅ Propeller fan 

 ᰃ໪亢৊⬉ᴎ Fan motor 

 ⬉ᴎᶊ Holder for fan motor 

 䱨亢ゟᵓ Partition plate 

 Ꮊջᬃᩥᵓ Left clapboard 

 乊Ⲫᵓ Top cover board 1
 ‫఼ޱދ‬㒘ӊ Condensor assembly 1
 
 ล᭭㔥㔽 Front net 1
 
Condenser inlet pipe 1
 ‫఼ޱދ‬䖯⇨ㅵ㒘ӊ
assembly  
 ಯ䗮䯔ㅵ䏃㒘ӊ 4-Ways valve pipe assembly 1 optional (for HP)
 
 ↯㒚ㅵㅵ䏃㒘ӊ Capillary assembly 1
 
 亢ᴎ⬉ᆍ Fan motor capacitor 

 ⬉ᆍᢅ᫔ Capacitor clamp 1
 
 य़㓽ᴎ⬉ᆍ Compressor capacitor 

 ⬉఼ᶊ Holder for E-parts  

 ッᄤᵓ Terminal board 

 ⬉⑤䖲᥹㒓य़ᵓ electricity cord clamp 


51
Technical Manual of AUX Air Conditioner

8.2.2 Outdoor unit for PAC12041

52
Technical Manual of AUX Air Conditioner

Parts List of Outdoor unit for PAC12041


Exploded
Chinese Name Name Pcs Remark
View No
 䴶ᵓ㔥㔽 Panel net 1

 䴶ᵓ Panel 1

 䕈⌕亢৊ Axial-flow fan 1

 亢৊⬉ᴎ Fan motor 1

 ⬉ᴎᶊ Motor bracket 1

 ‫఼ޱދ‬㒘ӊ Condenser assembly 1

 乊Ⲫᵓ Top cover 1

 䱨亢ゟᵓ Partition plate 1

 य़㓽ᴎ⬉ᆍ Compressor capacitor 1

 ⬉ᆍᢅ᫔ Capacitor clamp 1

 亢ᴎ⬉ᆍ Fan motor capacitor 1

 ⬉఼ᶊ Holder of electrical unit 1

 ッᄤᵓ Terminal board 1

 ᑩⲬ Chassis assembly 1

 ⬉఼Ⲫᵓ˄ᣪ᠟˅ Handle 1

 㚠䚼㔥㔽 Back net 1

 েջᵓ Right side plate 1

 ⎆䯔 Liquid valve 1

 ⇨䯔 Gas valve 1

 䯔ᵓ Valve plate 1

 य़㓽ᴎㅵ䏃㒘ӊ Compressor tubing assembly 1

 ‫఼ޱދ‬䖯⇨ㅵ㒘ӊ Air inlet tube of condenser 1

 य़㓽ᴎ Compressor 1

 ↯㒚ㅵ㒘ӊ Capillary 1

 Ꮊջᬃᩥᵓ Left side plate 1


53
Technical Manual of AUX Air Conditioner

8.3 Indoor unit for PAC18041 1

54
Technical Manual of AUX Air Conditioner

Parts List of Indoor unit for PAC18041


No ৡ⿄ Name Quantity Remark
1 䴶ᵓ Panel 1
2 䖛Ⓒ㔥㒘ӊ Filter 2
3 䴶ᵓवᠷ Panel clasper 3
4 ЁḚ Medium frame 1
5 ᇐ亢䮼 Horizontal airflow blade 1
6 ᇐ亢ᶊ Air-vent holder 2
7 ᇐ亢৊⠛䖲ᴚ Connecting rod for airflow vanes 1
8 ᇐ亢৊⠛ A Vertical airflow vanes A 7
9 ᇐ亢৊⠛ B Vertical airflow vanes B 7
10 ᇐ亢৊⠛ᠬᵓ Bracket of airflow vanes 1
11 䕈ᡓᬃᩥᑻ Bearing for indoor fan 1
12 䌃⌕亢৊ Cross-flow fan 1
13 㪌থ఼Ꮊᬃᶊ Left-hand propping holder for evaporator 1
14 㪌থ఼ᘏ៤ Evaporator assembly 1
15 ᑩᑻ chassis 1
16 ᑩᑻᎺᬃᩥ⊵≿ Foam of left chassis 1
17 ᣖᵓ㒘ӊ Mounting plate 1
18 ᑩᑻেᬃᩥ⊵≿ Foam of right chassis 1
19 ㅵ䏃य़ᵓ Pipe clamp 1
20 䋳⾏ᄤথ⫳఼ Negative ion 1
21 㪌থ఼েᬃᩥᵓ Right-hand propping holder for evaporator 1
22 ⬉ᴎय़Ⲫ Motor cover 1
23 ᅸ‫⬉ݙ‬ᴎ Indoor fan motor 1
24 ᇐ亢৊⠛ℹ䖯⬉ᴎ Step motor of airflow vanes 1
25 ⬉᥻Ⲧ Controller box 1
26 ᇐ亢৊⠛ Vertical airflow vanes 1
27 বय़఼ Transformer 1
28 ⬉⑤㒓ᢅ᫔ A Clamp of cable A 1
29 ⬉⑤㒓ᢅ᫔ B Clamp of cable B 1
30 ⏽ᑺӴᛳ఼ Room temperature sensor 1
31 PCB ᵓ Main PCB 1
32 ᇐ亢䮼ℹ䖯⬉ᴎ Step motor of airflow blade 1
33 Ⲭㅵ⏽ᑺӴᛳ఼ pipe temperature sensor 1
34 ッᄤᵓ Terminal board 1
35 ⬉᥻ⲦⲪ Cover of controller box 1
36 ⬉⑤㒓 Connection cable 1
37 ⬉⑤ᦦ༈ Power supply plug 1
38 㶎䩝Ⲫ Screw cover 1
39 ЁḚ᥹㒓Ⲫ Cover of medium frame 1
40 ᬃᩥᴚStand bar 1
41-42 ᰒ⼎♃ᵓ㒘ӊ Display light board assemblly 1
43 㺙佄䴶ᵓ Panel 1
Technical Manual of AUX Air Conditioner

Outdoor unit for PAC18041

56
Technical Manual of AUX Air Conditioner

Parts List of Outdoor unit for PAC18041


NO component Item Description Pcs Remark
 䴶ᵓ㔥㔽 3DQHOQHW  
 䴶ᵓ 3DQHO  
 䕈⌕亢৊ $[LDOIORZIDQ  

 亢৊⬉ᴎ )DQPRWRU  
 ⬉ᴎᶊ 0RWRUEUDFNHW  

 ‫఼ޱދ‬㒘ӊ &RQGHQVHUDVVHPEO\  

 乊Ⲫᵓ 7RSFRYHU  
 䱨亢ゟᵓ 3DUWLWLRQSODWH  

 
 य़㓽ᴎ⬉ᆍ &RPSUHVVRUFDSDFLWRU

 ⬉ᆍᢅ᫔ &DSDFLWRUFODPS  

 亢ᴎ⬉ᆍ )DQFDSDFLWRU  

 
 ⬉఼ᶊ +ROGHURIZLULQJXLQW

 ッᄤᵓ 7HUPLQDOERDUG  

 ᑩⲬ &KDVVLVDVVHPEO\  

 ⬉఼Ⲫᵓ˄ᣪ᠟˅ KDQGOH  

 㚠䚼㔥㔽 %DFNQHW  


 
 েջᵓ 5LJKWVLGHSODWH

 ⎆䯔 /LTXLGYDOYH  

 ⇨䯔 *DVYDOYH  


 䯔ᵓ 9DOYHSODWH  

 
 य़㓽ᴎㅵ䏃㒘ӊ &RPSUHVVRUWXELQJDVVHPEO\

 
 ‫఼ޱދ‬䖯⇨ㅵ㒘ӊ $LULQOHWWXEHRIFRQGHQVHU

 य़㓽ᴎ &RPSUHVVRU  

 ↯㒚ㅵ㒘ӊ &DSLOODU\DVVHPEO\  

 Ꮊջᬃᩥᵓ /HIWVLGHSODWH  

57
Technical Manual of AUX Air Conditioner

8.4 Indoor unit for PAC24041 1

58
Technical Manual of AUX Air Conditioner

Parts List of Indoor unit for PAC24041


No ৡ⿄ Name Quantity Remark
1 䴶ᵓ Panel 1
2 䖛Ⓒ㔥㒘ӊ Filter 2
3 䴶ᵓवᠷ Panel clasper 3
4 ЁḚ Medium frame 1
5 ᇐ亢䮼 Horizontal airflow blade 1
6 ᇐ亢ᶊ Air-vent holder 2
7 ᇐ亢৊⠛䖲ᴚ Connecting rod for airflow vanes 1
8 ᇐ亢৊⠛ A Vertical airflow vanes A 7
9 ᇐ亢৊⠛ B Vertical airflow vanes B 7
10 ᇐ亢৊⠛ᠬᵓ Bracket of airflow vanes 1
11 䕈ᡓᬃᩥᑻ Bearing for indoor fan 1
12 䌃⌕亢৊ Cross-flow fan 1
13 㪌থ఼Ꮊᬃᶊ Left-hand propping holder for evaporator 1
14 㪌থ఼ᘏ៤ Evaporator assembly 1
15 ᑩᑻ chassis 1
16 ᑩᑻᎺᬃᩥ⊵≿ Foam of left chassis 1
17 ᣖᵓ㒘ӊ Mounting plate 1
18 ᑩᑻেᬃᩥ⊵≿ Foam of right chassis 1
19 ㅵ䏃य़ᵓ Pipe clamp 1
20 䋳⾏ᄤথ⫳఼ Negative ion 1 optional
21 㪌থ఼েᬃᩥᵓ Right-hand propping holder for evaporator 1
22 ⬉ᴎय़Ⲫ Motor cover 1
23 ᅸ‫⬉ݙ‬ᴎ Indoor fan motor 1
24 ᇐ亢৊⠛ℹ䖯⬉ᴎ Step motor of airflow vanes 1
25 ⬉᥻Ⲧ Controller box 1
26 ᇐ亢৊⠛ Vertical airflow vanes 1
27 বय़఼ Transformer 1
28 ⬉⑤㒓ᢅ᫔ A Clamp of cable A 1
29 ⬉⑤㒓ᢅ᫔ B Clamp of cable B 1
30 ‫᥶⦃ݙ‬༈ Room temperature sensor 1
31 PCB ᵓ Main PCB 1
32 ᇐ亢䮼ℹ䖯⬉ᴎ Step motor of airflow blade 1
33 Ⲭㅵ᥶༈ pipe temperature sensor 1
34 ッᄤᵓ Terminal board 1
35 ⬉᥻ⲦⲪ Cover of controller box 1
36 ⬉⑤㒓 Connection cable 1
37 ⬉⑤ᦦ༈ Power supply plug 1
38 㶎䩝Ⲫ Screw cover 1
39 ЁḚ᥹㒓Ⲫ Cover of medium frame 1
40 ᬃᩥᴚ Stand bar 1
41 ᰒ⼎♃ᑻ Holder of display board 1
42 ᰒ⼎ሣ Display screen 1
43 䴶ᵓ Panel 1

59
Technical Manual of AUX Air Conditioner

Outdoor unit for PAC24041

60
Technical Manual of AUX Air Conditioner

Parts List of Outdoor unit for PAC24041


Exploded
Chinese Name Name Pcs Remark
View No
 Ꮊᬃᩥᵓ Left clapboard 

 䩶ϱ㔥㔽 Front net 

 ໻᠕༈㞾ᬏ㶎䩝 Big flat head self-drilling screw 

 乊Ⲫᵓ Top cover board 

 ໻䴶ᵓ Panel 

 ‫఼ޱދ‬ᘏ៤ Condensor assembly 

 েջᵓ Right side plate 

 ⬉ᆍᢅ᫔ Capacitor clamp 

 य़㓽ᴎ⬉ᆍ Compressor capacitor 

 ⬉ᴎ⬉ᆍ Fan motor capacitor 

 य़㒓Ⲫ Electric cover 

 ⬉఼ᶊ Holder for E-parts 

 Ѩԡッᄤᵓ Terminal board 

 䱨亢ゟᵓ Partition plate 

 य़㓽ᴎ㒘ӊ Compressor assembly 

 ↯㒚ㅵㅵ䏃㒘ӊ Capillary assembly 

 य़㓽ᴎㅵ䏃㒘ӊ Compressor pipe assenbly 

 ៾ℶ䯔㒘ӊ  Liquid valve assembly 

 ៾ℶ䯔㒘ӊ Gas valve assembly 

 ᑩⲬ㒘ӊ Chassis assembly 

कᄫῑߍえ݁㾦༈㞾ᬏ
 Phillips screw 
㶎䩝੠ᑇൿ೜㒘ড়ӊ 
 䯔ᵓ Valve plate 

䕈⌕亢᠛ Propeller fan 

 ⬉ᴎᶊ Holder for fan motor 

 ᅸ໪亢৊⬉ᴎ㒘ӊ Fan motor 

 कᄫῑⲬ༈㞾ᬏ㶎䩝 Phillips pan head self-drilling screw 


61