You are on page 1of 3

Relay

Relay
Solutions
Solutions
BR 930 SERIES

Siemens.com/mobility

QBCA1 Relay
A single wound dc biased ac immune contactor

General data
Contact Arrangement: 2HF 4B, 2HF 4F 4B
2HF 2F 4B, 2HF 2F 2B
Nominal Rated Voltage: 12V, 24V and 50V dc
Approximate Weight: 1.7 kg

Note: Refer to the following data sheets:


• 7-1-1 for general information and contact
ratings.
• 7-2-1 for dimensions.
• 8.2 for tools.
• 8.3 for plugboard and connector details.

Refer overleaf for speci c data.


B18558/1 Variant

Description
Originally designed to comply with BR speci cation 943. Other versions have since been added to the range.
The relay is identical to the QBA1 except that the four standard contacts in the ‘C’ stack are replaced by two heavy
duty contacts and the four contacts in the ‘B’ stack are replaced by magnetic blowouts for the heavy duty contacts.
The rating of the heavy duty front (HF) contacts is speci ed as follows:

1. They must close the circuit to a dc or single phase a.c. 110 V point machine with a performance to BS581 and
carry a current for a minimum of 10 seconds on a 50% dutycycle.

2. They must break a current of 30 amps in the foregoing conditions when the points are stalled a
minimum of 500 times during the service life of the relay.

3. The must effectively open the circuit with a current of 100 amps dc and a circuit emf of 130 V but need not
remain fully serviceable thereafter.

4. They must not weld when operated in a circuit of prospective current of not less than 200 amps and a circuit
emf of 130 V dc
Each heavy duty contact terminal is connected to two plugboard connectors in parallel,
A5 D5 each connector should be wired with two wires in parallel to handle the heavy currents
involved. To ensure efficient operation of the magnetic blowouts the connection
polarity shown below must be observed for dc operation.
A6 D6
Other speci c requirements for the relay are as follows:
A7 D7 1. The relay will operate when the positive
C1 C3
is applied to R1 negative to R2.

A8 D8 2. The relay will not operate when up to 20


times normal working voltage is applied
C2 C4
with the opposite polarity.
4 Back Contact Arrangement + ~

3. The application of up to 20 times nor- SUPPLY LOAD

A5 A7 mal voltage of either polarity must not - ~


change the characteristics of the relay
by more than 10%. C7 C5
A6 A8 4. The power consumption shall not
exceed 3 W.
2 Back Contact Arrangement C8 C6
5. The application of up to 1000 V, 50 Hz
shall not operate the relay.
These arrangements can be used to Polarities shown must be Plugboard Connectors
give detection of a welded heavy duty All of the speci ed characteristics observed when using a
dc supply Connectors external to
contact. apply with a coil temperature of 20°C. the Plugboard

Contact layout viewed from rear


A B C D A B C D A B C D A B C D
1 Supply 1 Supply Supply Supply
2 + 2
F + F F + F F +

3 Load 3 Load Load Load


4 - 4
F - F - F -

5 Load 5 Load Load Load


6
B + B 6
B + B B + B B +

7 Supply 7 Supply Supply Supply


8
B - B 8
B - B B - B B -

R1 coil + coil - R2 coil + coil - coil + coil - coil + coil -

R3 R4

2HF 4B 2HF 4F 4B 2HF 2F 4B 2HF 2F 2B

Packaging EMC Compliance


Q-Relays are packed in a carton holding ten relays; Q-Relays comply with the relevant emission
the same container is used for quantities of four requirements of EN 55014. It is considered that these
to nine relays. Quantities less than four are packed relays have inherent immunity to in-service electro-
individually in cardboard boxes, as are all train- magnetic disturbance.
carried relays. Each container has a bar-coded label A Technical Certi cate for EU Directive on EMC
affixed to the outside, stating details of the packaged (89/336/EEC) has been obtained.
relay(s) and the quantity therein.
Technical data
MAX FULL REQD No. OF
SIEMENS Part No. CONTACT RATED VOLTAGE COIL RES WDG SPEC MIN REL
PIN CODE OP. PLUGBOARD CONNECTORS REMARKS
(PAD No.) ARRANGEMENT (V dc) (OHMS) 1/108/- (V dc)
(V dc) J4137/3

B18548/1 172
2HF 4B 50 920 5 40 7.5 J4138/234 18 BRB Spec 943
(085/001515) BCFHK

B18548/2 170
2HF 4B 24 208 6 19.2 3.6 J4138/240 18 BRB Spec 943
(085/001505) BCEJK

B18548/3 2HF 2F 4B 50 XBCEK 920 5 40 7.5 J4138/239 22

B18548/4 2HF 2F 4B 24 XDEHJ 208 6 19.2 3.6 J4138/349 22

B18548/5 2HF 2F 2B 12 ADHKS 150 177 9.6 1.8 J4138/403 18

M25068
B18548/6 2HF 4F 4B 50 BEGHJ 940 188 40 7.5 J4138/465 26
Equivalent

M25069
B18548/7 2HF 4F 4B 24 BEFHJ 195 194 19.2 3.6 J4138/466 26
Equivalent

M25070
B18548/8 2 HF 4F 4B 12 ACBKS 55 192 9.6 1.8 J4138/435 26
Equivalent

B18548/9
2 HF 2F 4B 24 170 BCEJK 208 6 19.2 3.6 J4138/240 22 BRB Spec 943
(085/000961)

Un-drilled plugboard
Part No. E7218/1

Representation of Relay,
Plugboard and Retaining clip
(Clip Part No. J4136/1)

Siemens Ltd
Infrastructure & Cities Sector
Mobility and Logistics Division
Rail Automation Printed in the United Kingdom The information within this document
PO Box 79 contains general descriptions of the
Pew Hill Data Sheet 7-2-8
technical options available, which do not
Chippenham always have to be present in individual cases.
X342/55/000027 Revision 06
Wiltshire SN15 1JD The required features should therefore be
UK speci ed in each individual case at the time
www.siemens.com/rail-automation of closing the contract.