Confidential
Revision History
Revision Date Description
A 5th Dec 2007 Review of Rev C Circuit
th
B 17 Jan 2008 More details of Rev C Circuit review
th
C1 10 July 2008 C0 4th March 2008: Include feedback from review of this
document. C1 after further review of actions and effect
of removing optics
This document is maintained on a SVN source control system and is under Revision
control. The Revision Number is marked on every page, along with the date of the
entire document. The Revision Numbering comprises an Alphabetic Letter (A, B, C, D,
etc) for all major rewrites, and a letter for edits of sections of this document (0, 1, 2, 3,
etc). Where an update is made that does not involve reissue of the entire document,
then the Revision History sets out which pages are affected.
Page 2 Deep Life Ltd - For when equipment really must work
Confidential
Table of Contents
1 PURPOSE AND SCOPE .................................................................................. 4
2.3 Functionality...................................................................................................................... 4
2.10 Pages 8 and 11: Audio Codec 1/2, FPGA1/2 banks 6, 7, 8, Fibre interface................ 7
2.14 Page 15, 16 and 17: Scrubbers’, Legs & Arms, Gloves and Torso Heaters power
supplies ........................................................................................................................................ 8
Page 3 Deep Life Ltd - For when equipment really must work
Confidential
2.2 Revision
The circuit reviewed carries a date stamp 17th September 2007, and is marked Revision C.
2.3 Functionality
The Umbilical terminator provides the following functions:
1. Multiplexing and demultiplexing of data up and down umbilical media.
2. Support for a media interface board, normally a Optical Micro-Mux, to a
corresponding Micro-MUX board at the other end of the umbilical.
3. RS485 bidirectional data transfer to a corresponding MUX board at the other end of
the umbilical.
4. Framing protocol to pack and unpack the data
5. Digitally programmable and monitored power control for lighting, cameras, heating
and rebreather
6. Data routing hub with port to rebreather, head up display or PFD, using RS485 and
optical links in a redundant configuration
7. USB controller
8. Digital / analogue audio system interface for microphone and speaker between
diver and topside.
Page 4 Deep Life Ltd - For when equipment really must work
Confidential
9. Safety monitors: flood sensor, diver emergency sensor, helmet closure sensor
Page 5 Deep Life Ltd - For when equipment really must work
Confidential
Umbilical power supply is provided through 2x24V_IN and 2 ground terminals. There is only
one current sense on page 2. Power contacts are paralleled but there is no means to check
that both contacts are present. Diagnostics and self test functions may be substantially
improved with independent current sensors per power contact.
Action: Consider adding 3 main power current sensors to have sensor per pin.
Action: Input under voltage and converter output under/over voltage comparators shall be
added supplying FPGA and ARM microcontroller with power failed signals to allow them to
enter power saving mode. It also needs to be checked that power saving mode achieves
required 50mA maximum power consumption level for both halves of UT device.
Page 6 Deep Life Ltd - For when equipment really must work
Confidential
allows using single 12.288 MHz clock source and thus extra 48MHz clock source is not
required for the second half of UT.
LPC2478 ARM microcontroller shall use one USB port to connect to USB HUB for diver
side UT version and use second USB port for direct external connection to PC for top side
UT version to provide dual redundancy for the segment between PC and UT.
Objections are raised on this proposal by Verification, claiming it would be too difficult to
verify the software code, and a completely code-less system should be maintained. In this
case, the ARM processor will act only as a USB port: this is what is used now.
Action: Update schematics with USB transceiver reworks.
Action: Check whether any pullups or pulldowns are necessary on HELMET_CLOSED
and CHICKEN_SWITCH nets.
Action: Consider whether to replace FPGA2 with LPC2478 ARM microcontroller. Note: this
was done and was rejected – the current architecture appears to be the safest and avoids
all software.
Action: Add 48MHz clock oscillator.
Page 7 Deep Life Ltd - For when equipment really must work
Confidential
2.11 Page 12: USB HUB and clock oscillators
Main clock source for FPGAs shall be 48MHz as mentioned in 2.9.
Mentioned in 2.9 USB ID related reworks may affect this page.
2.14 Page 15, 16 and 17: Scrubbers’, Legs & Arms, Gloves and
Torso Heaters power supplies
Same comments as in 2.12. It may need more transistors in shut down control network if
they shall be controlled from either FPGA.
For heaters’ power supply it may make sense to consider using whole 24V amplitude
applied to the heaters with sigma-delta controller implemented inside FPGA replacing this
DC/DC converters with MOSFET switches.
Action: Actions from 2.12 with corresponding reference numbers.
Action: Consider alternative heaters control mechanism.
Page 8 Deep Life Ltd - For when equipment really must work
Confidential
2.17 Page 20: Audio amplifiers
Linear output must be buffered by AD797 to avoid audio performance degradation in the
link to spectrum correction equipment. At the moment signal is supplied unbuffered.
AD620 amplifiers are not specified for audio applications and have a large noise level.
Amplification ratio is also far from optimal. With MSM2C microphone for -22dB version the
output voltage is 1.6mV RMS assuming 2×10-2 sound pressure. To interface with WM8786
G=1000 shall be used.
Action: Buffer linear outputs and replace input amplifier with AD797 or similar amplifier
correcting amplification ratio.
Page 9 Deep Life Ltd - For when equipment really must work