FISA TEHNICA PRODUS TECHNICAL PRODUCT DATASHEET


Clasa beton proiectata : BCR 3.5 Designed concrete class: BCR 3.5
Ciment utilizat : I42.5R Cement: I42.5R
Granula maxima : 31.5 Max size of aggregates : 31.5
Raport maxim A/C: 0.45 Max W/C Ratio: 0.45
Aditivi utilizati: antrenor de aer Admixtures used: air-entraining
Aditiv antrenor de aer (cat este necesar) pentru 4.5% aer Air-entraining admixture: (as required) for 4.5% air
Clasa de consistenta: S2(T3) Consistency range : S2(T3)
Valoare consistenta [mm]: 50-90mm Slump Value [mm]: 50-90mm
Agregate utilizate : de balastiera Aggregates: natural aggregates
Densitate aparenta in stare proaspata [kg/mc] 2300-2340 Fresh apparent density [kg/mc]: 2300-2340
Mod vibrare : ENERGIC Vibration mode: ENERGIC
Tip Transport: Autobetoniera Transport Type: Mixer Truck
CARACTERISTICI FIZICO-MECANICE PHYSICO-MECHANICAL PROPERTIES
Durata de transport: Transport Time:
** va tine cont de perioada anului, temperatura exterioara, cerinte specifice ale santierului **will take into account the time of year, air temperature, specific site requirements
max. 35 min 10°C > T < 30°C max. 35 min 10°C > T < 30°C
max. 50 min T< 10°C max. 50 min T< 10°C
Rezistenta la incovoiere: Flexural Strenght:
- la varsta de 3 zile : min. 1.8 N/mmp - at age of 3 days : min. 1.8 N/mmp
- la varsta de 7 zile : min. 2.6 N/mmp - at age of 7 days : min. 2.6 N/mmp
- la varsta de 28 zile : min. 3.5 N/mmp - at age of 28 days : min. 3.5 N/mmp
Rezistenta la compresiune: Compressive Strenght:
- la varsta de 3 zile : min. 15 N/mmp - at age of 3 days : min. 15 N/mmp
- la varsta de 7 zile : min. 23 N/mmp - at age of 7 days : min. 23 N/mmp
- la varsta de 28 zile : min. 30 N/mmp - at age of 28 days : min. 30 N/mmp
DOMENII DE UTILIZARE APPLICATIONS

Aplicatii la interior si exterior, in elemente expuse la inghet-dezghet, in medii cu agresivitate chimica Indoor and outdoor applications, in elements subjected to freezing-and-thawing cycles,
moderata si cu solicitare intensa la uzura; environments exposed to moderate chemical aggression and high wear applications;

Betoane utilizate in straturile de rezistenta si uzura ale strazilor cu o banda de circulatie si alei Concrete platforms used in layers and wear resistance of the streets with one lane roads and
carosabile; alleys;
Locuri de stationare, platforme de parcare si portuare; Stationary places, platforms and port parking;
Drumuri si strazi cu trafic usor; Roads and streets with light traffic;
Garaje & parkinguri. Garages & parking places.
Se poate pune in opera cu pompa: NU Can be discharged by pump: NO
Se poate finisa mecanizat
DA Power trowel can be used: YES
(elicopterizare):
RECOMANDARI RECOMMENDATIONS

In perioada de timp friguros la temperaturi ale aerului mai mici de + 5°C nu se recomanda turnarea During the cold weather at air temperatures below + 5°C it is not recommend to pour concrete for
betoanelor rutiere. roads.

Pentru perioada de timp calduros se recomanda prepararea mixului cu aditiv intarzietor de priza In hot periods present mix design is to be done with Retarder Accelerator Admixture Type, in a
intr-un dozaj recomandat de producatorul de aditiv si testat in prealabil in laborator. dosage recommended by admixture supplier and tested at concrete plant laboratory.

Conform : NE 014-2002 According with : NE 014-2002


Fisa Tehnica Beton Clasa BcR 4 Technical Datasheet Concrete Type BcR 4

FISA TEHNICA PRODUS TECHNICAL PRODUCT DATASHEET


Clasa beton proiectata : BCR 4 Designed concrete class: BCR 4
Ciment utilizat : I42.5R Cement: I42.5R
Granula maxima : 31.5 Max size of aggregates : 31.5
Raport maxim A/C: 0.45 Max W/C Ratio: 0.45
Aditivi utilizati: antrenor de aer Admixtures used: air-entraining
Aditiv antrenor de aer (cat este necesar) pentru 4.5% aer Air-entraining admixture: (as required) for 4.5% air
Clasa de consistenta: S2(T3) Consistency range : S2(T3)
Valoare consistenta [mm]: 50-90mm Slump Value [mm]: 50-90mm
Agregate utilizate : de balastiera Aggregates: natural aggregates
Densitate aparenta in stare proaspata [kg/mc] 2300-2340 Fresh apparent density [kg/mc]: 2300-2340
Mod vibrare : ENERGIC Vibration mode: ENERGIC
Tip Transport: Autobetoniera Transport Type: Mixer Truck
CARACTERISTICI FIZICO-MECANICE PHYSICO-MECHANICAL PROPERTIES
Durata de transport: Transport Time:
** va tine cont de perioada anului, temperatura exterioara, cerinte specifice ale santierului **will take into account the time of year, air temperature, specific site requirements
max. 35 min 10°C > T < 30°C max. 35 min 10°C > T < 30°C
max. 50 min T< 10°C max. 50 min T< 10°C
Rezistenta la incovoiere: Flexural Strenght:
- la varsta de 3 zile : min. 2 N/mmp - at age of 3 days : min. 2 N/mmp
- la varsta de 7 zile : min. 3 N/mmp - at age of 7 days : min. 3 N/mmp
- la varsta de 28 zile : min. 4 N/mmp - at age of 28 days : min. 4 N/mmp
Rezistenta la compresiune: Compressive Strenght:
- la varsta de 3 zile : min. 17.5 N/mmp - at age of 3 days : min. 17.5 N/mmp
- la varsta de 7 zile : min. 26 N/mmp - at age of 7 days : min. 26 N/mmp
- la varsta de 28 zile : min. 35 N/mmp - at age of 28 days : min. 35 N/mmp
DOMENII DE UTILIZARE APPLICATIONS

Aplicatii la interior si exterior, in elemente expuse la inghet-dezghet, in medii cu agresivitate chimica Indoor and outdoor applications, in elements subjected to freezing-and-thawing cycles,
moderata si cu solicitare intensa la uzura; environments exposed to moderate chemical aggression and high wear applications;

Betoane utilizate in straturile de rezistenta si uzura ale strazilor cu doua benzi de circulatie si alei Concrete platforms used in layers and wear resistance of the streets opperating with two traffic
carosabile; lanes and alleys;
Drumuri si platforme industriale, platforme de parcare si portuare; Roads or platforms in industrial sites, platforms and port parking;
Drumuri si strazi cu trafic usor sau mediu; Roads and streets with medium or light traffic;
Garaje & parkinguri. Garages & parking places.
Se poate pune in opera cu pompa: NU Can be discharged by pump: NO
Se poate finisa mecanizat
DA Power trowel can be used: YES
(elicopterizare):
RECOMANDARI RECOMMENDATIONS

In perioada de timp friguros la temperaturi ale aerului mai mici de + 5°C nu se recomanda turnarea During the cold weather at air temperatures below + 5°C it is not recommend to pour concrete for
betoanelor rutiere. roads.

Pentru perioada de timp calduros se recomanda prepararea mixului cu aditiv intarzietor de priza In hot periods present mix design is to be done with Retarder Accelerator Admixture Type, in a
intr-un dozaj recomandat de producatorul de aditiv si testat in prealabil in laborator. dosage recommended by admixture supplier and tested at concrete plant laboratory.

Conform : NE 014-2002 According with : NE 014-2002


Fisa Tehnica Beton Clasa BcR 4.5 Technical Datasheet Concrete Type BcR 4.5

FISA TEHNICA PRODUS TECHNICAL PRODUCT DATASHEET


Clasa beton proiectata : BCR 4.5 Designed concrete class: BCR 4.5
Ciment utilizat : I42.5R Cement: I42.5R
Granula maxima : 31.5 Max size of aggregates : 31.5
Raport maxim A/C: 0.45 Max W/C Ratio: 0.45
Aditivi utilizati: antrenor de aer Admixtures used: air-entraining
Aditiv antrenor de aer (cat este necesar) pentru 4.5% aer Air-entraining admixture: (as required) for 4.5% air
Clasa de consistenta: S2(T3) Consistency range : S2(T3)
Valoare consistenta [mm]: 50-90mm Slump Value [mm]: 50-90mm
Agregate utilizate : nisip natural + agregate concasate Aggregates: natural sand + crushed aggregates
Densitate aparenta in stare proaspata [kg/mc] 2300-2340 Fresh apparent density [kg/mc]: 2300-2340
Mod vibrare : ENERGIC Vibration mode: ENERGIC
Tip Transport: Autobetoniera Transport Type: Mixer Truck
CARACTERISTICI FIZICO-MECANICE PHYSICO-MECHANICAL PROPERTIES
Durata de transport: Transport Time:
** va tine cont de perioada anului, temperatura exterioara, cerinte specifice ale santierului **will take into account the time of year, air temperature, specific site requirements
max. 35 min 10°C > T < 30°C max. 35 min 10°C > T < 30°C
max. 50 min T< 10°C max. 50 min T< 10°C
Rezistenta la incovoiere: Flexural Strenght:
- la varsta de 3 zile : min. 2.3 N/mmp - at age of 3 days : min. 2.3 N/mmp
- la varsta de 7 zile : min. 3.4 N/mmp - at age of 7 days : min. 3.4 N/mmp
- la varsta de 28 zile : min. 4.5 N/mmp - at age of 28 days : min. 4.5 N/mmp
Rezistenta la compresiune: Compressive Strenght:
- la varsta de 3 zile : min. 20 N/mmp - at age of 3 days : min. 20 N/mmp
- la varsta de 7 zile : min. 30 N/mmp - at age of 7 days : min. 30 N/mmp
- la varsta de 28 zile : min. 40 N/mmp - at age of 28 days : min. 40 N/mmp
DOMENII DE UTILIZARE APPLICATIONS

Aplicatii la interior si exterior, in elemente expuse la inghet-dezghet, in medii cu agresivitate chimica Indoor and outdoor applications, in elements subjected to freezing-and-thawing cycles,
moderata si cu solicitare intensa la uzura; environments exposed to moderate chemical aggression and high wear applications;

Autostrazi, drumuri si strazi cu trafic mediu, greu sau foarte greu; Highways, roads and streets with medium or heavy traffic or very hard roads;

Drumuri si platforme industriale cu trafic greu; Roads or platforms in industrial sites with heavy traffic;

Drumuri de exploatare cu doua benzi de circulatie cu trafic greu sau foarte greu; Service roads with two traffic lanes with heavy or very hard traffic;

Piste, cai de rulare si platforme pentru aeroporturi interne sau internationale. Runways, taxiways and platforms for domestic or international airports.
Se poate pune in opera cu pompa: NU Can be discharged by pump: NO
Se poate finisa mecanizat
DA Power trowel can be used: YES
(elicopterizare):
RECOMANDARI RECOMMENDATIONS

In perioada de timp friguros la temperaturi ale aerului mai mici de + 5°C nu se recomanda turnarea During the cold weather at air temperatures below + 5°C it is not recommend to pour concrete for
betoanelor rutiere. roads.

Pentru perioada de timp calduros se recomanda prepararea mixului cu aditiv intarzietor de priza In hot periods present mix design is to be done with Retarder Accelerator Admixture Type, in a
intr-un dozaj recomandat de producatorul de aditiv si testat in prealabil in laborator. dosage recommended by admixture supplier and tested at concrete plant laboratory.

Conform : NE 014-2002 According with : NE 014-2002


Fisa Tehnica Beton Clasa BcR 5 Technical Datasheet Concrete Type BcR 5

FISA TEHNICA PRODUS TECHNICAL PRODUCT DATASHEET


Clasa beton proiectata : BCR 5 Designed concrete class: BCR 5
Ciment utilizat : I42.5R Cement: I42.5R
Granula maxima : 31.5 Max size of aggregates : 31.5
Raport maxim A/C: 0.45 Max W/C Ratio: 0.45
Aditivi utilizati: antrenor de aer Admixtures used: air-entraining
Aditiv antrenor de aer (cat este necesar) pentru 4.5% aer Air-entraining admixture: (as required) for 4.5% air
Clasa de consistenta: S2(T3) Consistency range : S2(T3)
Valoare consistenta [mm]: 50-90mm Slump Value [mm]: 50-90mm
Agregate utilizate : nisip natural + cribluri Aggregates: natural sand + crushed aggregates
Densitate aparenta in stare proaspata [kg/mc] 2300-2340 Fresh apparent density [kg/mc]: 2300-2340
Mod vibrare : ENERGIC Vibration mode: ENERGIC
Tip Transport: Autobetoniera Transport Type: Mixer Truck
CARACTERISTICI FIZICO-MECANICE PHYSICO-MECHANICAL PROPERTIES
Durata de transport: Transport Time:
** va tine cont de perioada anului, temperatura exterioara, cerinte specifice ale santierului **will take into account the time of year, air temperature, specific site requirements
max. 35 min 10°C > T < 30°C max. 35 min 10°C > T < 30°C
max. 50 min T< 10°C max. 50 min T< 10°C
Rezistenta la incovoiere: Flexural Strenght:
- la varsta de 3 zile : min. 2.5 N/mmp - at age of 3 days : min. 2.5 N/mmp
- la varsta de 7 zile : min. 3.8 N/mmp - at age of 7 days : min. 3.8 N/mmp
- la varsta de 28 zile : min. 5.0 N/mmp - at age of 28 days : min. 5.0 N/mmp
Rezistenta la compresiune: Compressive Strenght:
- la varsta de 3 zile : min. 22.5 N/mmp - at age of 3 days : min. 22.5 N/mmp
- la varsta de 7 zile : min. 33.8 N/mmp - at age of 7 days : min. 33.8 N/mmp
- la varsta de 28 zile : min. 45 N/mmp - at age of 28 days : min. 45 N/mmp
DOMENII DE UTILIZARE APPLICATIONS

Aplicatii la interior si exterior, in elemente expuse la inghet-dezghet, in medii cu agresivitate chimica Indoor and outdoor applications, in elements subjected to freezing-and-thawing cycles,
moderata si cu solicitare intensa la uzura; environments exposed to moderate chemical aggression and high wear applications;

Autostrazi, drumuri si strazi cu trafic greu sau foarte greu; Highways, roads and streets with heavy traffic or very hard roads;

Drumuri si platforme industriale cu trafic greu sau foarte greu; Roads or platforms in industrial sites with heavy traffic or very hard roads;

Drumuri de exploatare cu doua benzi de circulatie cu trafic greu sau foarte greu; Service roads with two traffic lanes with heavy or very hard traffic;

Piste, cai de rulare si platforme pentru aeroporturi interne sau internationale. Runways, taxiways and platforms for domestic or international airports.
Se poate pune in opera cu pompa: NU Can be discharged by pump: NO
Se poate finisa mecanizat
DA Power trowel can be used: YES
(elicopterizare):
RECOMANDARI RECOMMENDATIONS

In perioada de timp friguros la temperaturi ale aerului mai mici de + 5°C nu se recomanda turnarea During the cold weather at air temperatures below + 5°C it is not recommend to pour concrete for
betoanelor rutiere. roads.

Pentru perioada de timp calduros se recomanda prepararea mixului cu aditiv intarzietor de priza In hot periods present mix design is to be done with Retarder Accelerator Admixture Type, in a
intr-un dozaj recomandat de producatorul de aditiv si testat in prealabil in laborator. dosage recommended by admixture supplier and tested at concrete plant laboratory.

Conform : NE 014-2002 According with : NE 014-2002