You are on page 1of 4

pH

in Fruit Processes

pH measurement in jam, jelly,


marmalade and fruit sauce.
Background
As jam, jelly, marmalade and fruit sauce require high and consistent
quality, it is important to control the pH value during the process. The
quality criteria greatly influence the flavor, color and consistency. The pH
value affects gelling behavior, flavor and shelf life of the product.
Generally, edible acids (e.g., citric acid) are added to lower the pH. The gel
formation by pectins takes place at a certain pH range depending on
soluble solids content (see Figure 1).

Solids

°Brix
80

75
Application
Process Analytics

70
liquid gelled pre-gelled
65

60

Figure 1: 55
Relationship of pH value, gel pH in
3.6 3.4 3.2 3.0 2.8 2.6
behaviour and sugar content. the gel
Therefore, the feed of edible acids is controlled by on-line Edible acids are added until the pH reaches the recommen-
pH measurement during the production of jam, jelly, ded value, normally 2.8 to 3.2 depending upon the product.
marmalade and fruit sauce. This procedure offers high safety During the cooking process, the pH value is continuously
as well as the possibility for automation of the process. controlled so that it can be adjusted by the addition of more
edible acids. If the pH value is too low (e.g. apple pectins 2.8),
the gel becomes hard and brittle and begins to form too
Process early. If a certain pH limit is exceeded, gelation is no longer
possible.
First, the basic materials (e.g. fruit and sugar) are blended
and pasteurized at 105 °C (220 °F). The process usually
contains 60 to 65 % sugar and sometimes fruit pieces. After Mettler-Toledo Solution
cooling down, the mass is transferred to the cooking-batch
where additives such as pectins, flavors and edible acids are Mettler-Toledo features three different measuring systems,
fed to the pre-mix in a closed vessel at 80 to 100 °C (176 to depending on measurement preferences and specific require-
212 °F) and 1.2 to 1.3 bar (18 to 19 psi) static pressure under ments. All Mettler-Toledo pH electrodes are compatible with
agitation. Temperature and pressure depend on the size of the the transmitter pH 2100 e.
vessel, place of installation, and product (see Figure 2).

2 3 4 5 6 7
A
1
B C C

E
F

D G G

A Product inlet E Product outlet 1 Horizontal food blender 5 Surface heat exchange
B Steam F De-aeration 2 Vacuum de-aeration unit 6 Buffer storage area
C Cooling G Cooling outlet 3 Scraped surface heater 7 Surface heat exchange
D Condensate 4 Holding tube

Figure 2:
Example of a continuous process-line for fruit production.

ApplicationNote METTLER TOLEDO

2
The first recommended system is the combined pH The InTrac 798, which allows electrode cleaning/
electrode InPro 3300 with a solid-state pH sensitive part sterilization/exchange without process interruption, also
(ISFET) for highly demanding processes in the food industry. protects the electrode form hot alkali during plant CIP
The non-glass technology eliminates the risk of broken glass procedures. The InTrac 798 is available with a choice of
in your process. Together with the hygienically designed approved commercial hygienic adapters from Mettler-Toledo
retractable housing InTrac 798 this electrode offers real-time (safety weld-in sockets DN25), Tuchenhagen-Varivent,
pH control of the food process without time-consuming TriClamp and Neumo.
grab-sample analysis.
Retractable housing InTrac® 798
pH non-glass electrode InPro® 3300  Safety: the hygienic design and
 Process safety: the sensor is virtually sterilizable flushing chamber prevent
unbreakable due to the non-glass design. any risk of contamination. EHEDG
 Hygienic design: EHEDG tested, compliance tested and 3-A compliant.
with 3-A sanitary standards, FDA compliant  Time and cost saving: access to
materials, fully sterilizable. electrode for cleaning and sterili-
 High-productivity and cost effective: zation without process interruption.
real-time control over the process without  Easy handling: fits to a wide variety
time-consuming grab-sample analysis. of hygienic fittings dedicated for food
 Rugged IP68 rated quick connect applications; uniform sensor length.
VarioPin (VP) connector.  Improved safety standard due to a
 Pressure resistance (PED) – new integrated electrode detection
compliant with regulations. system.

The non-glass pH electrode is an unbreakable break-


through for the food industry. The sensor is equipped with a Transmitter pH 2100 e
solid-state pH sensitive part (ISFET) and with a high tempe-  Operational safety and reliability
rature reference system with gel electrolyte, making the due to continuous sensor and
electrode practically maintenance-free. It is pressure-resistant transmitter diagnostics.
up to 6 bar at 130 °C (PED 97) and fully sterilizable, either  Easy installation and self-
in-situ or in an autoclave. The 45 ° design of the electrode end explanatory operation through
prevents air bubbles being trapped at the pH-sensitive tip. pictographic user interface and
Sensoface®.
Compliance with 3-A sanitary standards provides assurance  Loop autonomy and maintenance free pH measurement
that dairy products, food and other microbiologically due to integrated PID controller
sensitive products are protected from contamination. EHEDG  Flexibility with 4-wire installation or alternatively
tests attest that InPro 3300 electrodes fully comply with the 2-wire execution with HART® and/or Profibus®
criteria for hygienic design. and/or FF communication and EEx applications.
 Power feed for ISFET preamplifier already integrated
as standard.

ApplicationNote METTLER TOLEDO

3
The second system is a gel-filled InPro 3253 installed in Retractable housing InTrac® 777 e
an InTrac 777 e or in an InTrac 798 retractable housing. The  Safety:
InPro 3253 with built-in RTD and VP connector is pre- The patented immersion tube design
pressurized. The silver-ion trap prevents back-flow reference isolates the sensor on retraction and
cell contamination and diaphragm clogging. The InTrac guarantees complete separation of
housings allow electrode cleaning/sterilization/exchange the process from the outside environ-
without process interruption. ment. Safety interlocks prevent elec-
trode removal from housing while in
Combination pH electrode InPro® 3253 measuring position.
 The InPro 3253 electrode is filled with  Time and cost-saving:
liquid-reference electrolyte which is pre- The retractable design allows
pressurized to 4 bar (58 psi). electrode to be serviced and
 The electrode is provided with a patented calibrated without process
silver-ion trap to prevent diaphragm fouling interruption.
in sulfide-containing media.
 Equipped with an integrated RTD for The third alternative system is a gel-filled InPro 3253
automatic temperature compensation installed in an InFit 761-25 CIP stationary housing.
during calibration and process, which
ensures reliable measurements. Stationary housing InFit® 761-25 CIP
 The robust, autoclavable VarioPin (VP)  Steam-sterilizable & autoclavable for
connector to IP 68 guarantees maximum hygienic and CIP/SIP applications.
process safety and accurate electrode  Meets 3-A guidelines and EHEDG certifi-
connection and disconnection from the cation to ensure maximum cleanability.
cable for ease of replacement.  Exclusive O-ring positioning guarantees
 The internal over-pressure ensures gradual electrolyte perfect sealing, permitting full CIP pro-
outflow efficiently cleaning the diaphragm and cedures to be performed without any
preventing influx of process medium into the reference compromise of sterility.
electrolyte.  Specially designed smooth surfaces of the housing and
O-rings prevent the adherence of microorganisms.
 Recommended for use with Mettler-Toledo safety weld-
in sockets to provide the highest level of protection for
personnel, equipment and the environment.

Mettler-Toledo GmbH
Process Analytics INGOLD
Im Hackacker 15 Leading Process Analytics
CH-8902 Urdorf
Switzerland

.mtpro.com
www

Subject to technical changes.


© Mettler-Toledo GmbH, Process Analytics
Designed in Switzerland. 08 / 04

You might also like