You are on page 1of 13

Radware Alteon

Alteon Application Switch 24.1


Release Notes
November 9th, 2009
Radware Alteon: 24.1 Release Notes

TABLE OF CONTENTS

RELEASE SUMMARY ............................................................................................................................................................ 3


SUPPORTED PLATFORMS AND MODULES ............................................................................................................................ 3
MAINTENANCE FIXES .......................................................................................................................................................... 5
KNOWN LIMITATIONS ......................................................................................................................................................... 6
INSTALLING ALTEON APPLICATION SWITCH OPERATING SYSTEM 24.1.0.0 .......................................................................... 6
VERIFY SWITCH CONNECTIVITY ........................................................................................................................................................ 7
UPGRADING FROM VERSION 22.X/23.X TO 24.X ................................................................................................................. 7
UPGRADING FROM VERSION 21.0.4 OR LATER .................................................................................................................... 8
UPGRADING FROM A VERSION PRIOR TO 21.0.4 ............................................................................................................... 10
INSTALLATION CONSIDERATIONS ...................................................................................................................................... 12

Page 2
Radware Alteon: 24.1 Release Notes

Release Summary
Release Date: October, 2009
Objective: Software Minor release, addressing
 39 major software issues
 New Licensing Mechanism
 Rebranded to the Radware Alteon Brand “Alteon Application Switch” or AAS

Supported Platforms and Modules


Alteon Application Switch Operating System 24.1.0.0 is supported on the Alteon Application Switch
platforms, outlined in table below.

All Alteon Application Switch models now have an E5 variant that contains the following
enhancements:
 SP memory - E5 variants contain 256 MB of SP memory instead of the 128 MB present in base
models.
 RoHS compliance - E5 variants are compliant with the European Union Restriction of Hazardous
Substances (RoHS) directive.

Some E5 variants also have AC and DC power options available.

The E5 variant is indicated by the inclusion of an E in the model name.

This version is supported by the following platforms:


 AAS 2208 & 2208E
 AAS 2216 & 2216E
 AAS 2424 & 2424E
 AAS 2424-SSL & 2424-SSL E
 AAS 3408 & 3408E

Software base:
Name Type Description
AAS-24.1.0.0-3000-AlteonOS.img The image file used for upgrading the Alteon Application
Image
Switch 3408 through FTP or TFTP
AAS-24.1.0.0-3000-Serial.img Binary The image file used for upgrading the Alteon Application
Image Switch 3408 through a serial download.
AAS-24.1.0.0-2000-AlteonOS.img The image file used for upgrading the Alteon Application
Image
Switch 2000 Series through FTP or TFTP
AAS-24.1.0.0-2000-Serial.img Binary The image file used for upgrading the Alteon Application
Image Switch 2000 series through a serial download.
AAS-24.1.0.0-Boot.img Boot The image file used to update the boot kernel on Alteon
Image Application Switches running version 24.0.
The Management Information Base (MIB) files that
AAS-24.1.0.0-Mibs.zip MIB
support version 24.0.

Page 3
Radware Alteon: 24.1 Release Notes

File Name Size MD5 Checksum


AAS-24.1.0.0-2000-AlteonOS.img 3826973 d7cd325a214450af19fb20b26fe9fdad
AAS-24.1.0.0-2000-Serial.img 7387751 69eac41479128733957adedf53b74439
AAS-24.1.0.0-3000-AlteonOS.img 3808601 d0dae74ffd15d9e02574944ec632502f
AAS-24.1.0.0-3000-Serial.img 7369379 25e28cab1cd9db347e0c9b27dda772e3
AAS-24.1.0.0-Boot.img 3560778 6ee8b1ee9e3caa9c46c02d3351bc74b1
AAS-24.1.0.0-Mibs.zip 286366 3a41264bdfd31d13e1b8c2a6c9236de5

Note: Starting with version 24.1.0.0, Radware has integrated a new licensing mechanism. The switch
supports multiple tools to help make the transition as transparent as possible. Performing an upgrade will
not remove the previous Nortel Keys, and the downgrade process will recognize them automatically. For
more information, see the Alteon Application Switch Licensing Guide versions 25.1.0.0 and 24.1.0.0.

Note: Customers upgrading from 24.x train to 25.x train will have to contact the support directly in
order to obtain upgrade password.

Note: Radware recommends that customers upgrade their Alteon Application Switch Operating
System boot image to the software version currently running on the switch.

Note: ASEM 6.1.0.0 must be used with switches running Alteon Application Switch Operating
System 24.1.0.0. Attempting to manage switches running these software versions with older
management software can result in errors and mis-configuration of the switch.

Note: In order to maximize configuration compatibility during upgrade, Radware does not recommend
upgrading from discontinued releases like 23.x to a 25.x-based release. Please perform an interim
upgrade to a 24.x-based release before upgrading to a 25.x-based release.

Page 4
Radware Alteon: 24.1 Release Notes

Maintenance Fixes
The following is a cumulative list of bugs fixed since the release of version 24.1.0.0:.

ID Description
1 ALT00001092 Insert Cookie persistency does not work for operation disabled servers
2 ALT00003149 Dot3internalmactransit errors were fixed.i
ALT00009557
ALT00005911
ALT00021363
3 ALT00010291 OSPF: When changing the area type from transit to stub, the switch gets panic.
ALT00005308
4 ALT00021685 The session timeout is changed on a new session when it receives a re-transmitted SYN.
ALT00021303
ALT00004966
ALT00021684
5 ALT00011117 HTTP requests are looped back to the default gateway as the VIP is no longer reachable,
when VIP becomes deaf after config/apply.
6 ALT00021090 In IPv6 VRRP active-standby configuration, both Alteons take on the Master state.
7 ALT00001863 2424 23.2.2 - MSS of next hop is set to 0 and should not be.
8 ALT00006197 SFP G-BIC causes the MP CPU to reach 100% utilization.
1. The MP reaches 100% CPU utilization when an SFP is inserted into the unit, staying
at 100% for about 15 seconds.
2. The MP reaches 100% CPU utilization when resetting the unit and SFP G-BICs are
inserted, staying at 100% for about 30 seconds.
9 ALT00008541 SIP via header NAT issue: The original IP that is embedded in the branch subfield gets
NATed.
10 ALT00011850 Unable to add character string to real 257 if RIP does not exist.
11 ALT00021068 Static route is not added properly in routing table when deleting the gateway and adding
stat.
12 ALT00004511 LDAP SLB weighting of servers not working correctly.
13 ALT00010812 Adding/removing static route causes VIP ARP entry is removed out of ARP table.
14 ALT00008910 When the client IP is the same as the VIP in a VSR-configured AAS setup, and the IP
service is configured in the virtual server with the "nonat" option enabled, the client
sends the traffic to any IP (for example: telnet w.x.y.z) and then AAS receives a panic.
15 ALT00021117 UDP Server Fragmentation does not get processed by the server
16 ALT00003560 When the switch is defined with Jumbo frames enabled, performing packet capture in
God-mode (/mai/pk/cap) will result in a panic when a Jumbo frame is received.
17 ALT00003246 GSLB: VRRP backup returning remote VIP when queried and gmetric local used.
18 ALT00012375 Filter session mirroring VLAN ID is not the same on the backup device.
19 ALT00021088 Fixed data mover panic caused due to heavy VMA traffic.
20 ALT00002333 Rapid Spanning tree convergence takes much longer when trunk ports are configured.

Page 5
Radware Alteon: 24.1 Release Notes

21 ALT00009413 The device is rebooted a few times with the error message "Software Panic” when
running code from version 24.0.0.
22 ALT00011380 After a traffic hit, the Layer 7 pattern matching allow filter does not work.
23 ALT00004446 SW PANIC when applying HC content more than 125 characters for some services.
24 ALT00021081 SFP ERROR message is generated for the wrong port.
25 ALT00021157 Overflow server activation syslog for unrelated real server is generated.
26 ALT00001487 In an RTS, session could not establish after remove one ip address from multi-network's
server NIC
Note: The new command was added under /cfg/slb/adv/rtsiplkup. "Ip address" is
considered as the parameter in addition to mac address parameter
which will help in identifying the unique machine from which the packet has been
received.
27 ALT00021846 Panic (datamover) when running traffic according to case ALT00021088.
28 ALT00012911 GSLB Network Rule not working when Source IP (SIP) is used.
29 ALT00003753 When there is a high volume of DNS traffic, SP-CPU utilization goes above 90%.
30 ALT00005472 NAS sets session timer age to 0 on voice traffic after a failover.
31 ALT00001997 The SFO mirrored session remains on the new master with the maximum age after
failover.
32 ALT00021349 Panic when viewing port current configuration.
33 ALT00021472 BBI shows Virtual Server Stats incorrectly when /cfg/slb/adv/vstat e
34 ALT00006786 Secondary backup does not come up when backup overflows.
35 ALT00021105 Having two groups where one using bandwidth metrics and the other using a hash
metric, the hash metric does not work. This is a documentation issue, manual was
updated.
36 ALT00022823 IPinIP fragments are discarding by the device.
37 ALT00022824 L2TP traffic fragments silently discarded.
38 ALT00008791 Question: 25.0.0 Panic Dump Analysis related to multiple connections to management
ALT00022647 port.
39 ALT00004925 maxcon is not respected with SIP

Known Limitations
N/A

For other known issues, please refer to the software limitations section of the 24.0.0.0 Release Notes,
product Release Notes, and technical documentation available from the Alteon Technical Support web
site at: http://www.radwareAlteon.com.

Installing Alteon Application Switch Operating System 24.1.0.0

Page 6
Radware Alteon: 24.1 Release Notes

The following procedures outline how to install the Alteon Application Switch Operating System
24.1.0.0 image on the Alteon Application Switch:
 Upgrading from version 22.x/23.x to 24.x
 Upgrading from version 21.0.4 or greater
 Upgrading from a version prior to 21.0.4

A separate procedure is required for switches running versions of the Alteon Application Switch
Operating System earlier than 21.0.4 because the Alteon Application Switch Operating System 24.0.0.0
. image size exceeds 3 MB. Versions earlier than 21.0.4 cannot directly support software downloads
through TFTP of files larger than 3 MB.

The Alteon Application Switch supports software downloads using TFTP, FTP or a serial connection.
The procedures in this section describe a software download using TFTP or FTP. For information on
performing a serial download, refer to Appendix C - Performing a Serial Download of the Alteon
Application Switch Operating System Command Reference.

Verify switch connectivity


Before attempting a software download, ensure that the application switch has connectivity to the
software download server. By default, the data ports are used to connect to download servers.
If the management port is to be used to connect to an FTP or TFTP server, use the following command:
>> Main# /cfg/sys/mmgmt/tftp mgmt

To check switch connectivity to the software download server, use the –m option with the ping
command to contact the server. The following example illustrates a usage of this command:
>> Main# ping 120.1.1.51 -m
[host 120.1.1.51, max tries 5, delay 1000 msec]
120.1.1.51: #1 ok, RTT 2 msec.
120.1.1.51: #2 ok, RTT 1 msec.
120.1.1.51: #3 ok, RTT 1 msec.
120.1.1.51: #4 ok, RTT 1 msec.
120.1.1.51: #5 ok, RTT 1 msec.
Ping finished.

Upgrading from version 22.x/23.x to 24.x


The Alteon Application Switch Operating System running on image 22.x/23.x cannot be upgraded
directly to a 24.1.0.0 image. To achieve maximum configuration compatibility when upgrading from a
previous release of software to version 24.1.0.0, do the following:
1. Check the Alteon Application Switch image:
/info/sys/general
The Alteon Application Switch image details appear. If the switch image is 22.x, go to step 2.
Otherwise, go to step 3.

Page 7
Radware Alteon: 24.1 Release Notes

2. Upgrade the Switch image from 22.x to 23.x.


The Alteon Application Switch image is 23.x.
3. Upgrade the Switch image from 23.x to 24.x.
The Alteon Application Switch image is 24.x.

Upgrading from version 21.0.4 or later


If the version of Alteon Application Switch Operating System on the switch is 21.0.4 or later, follow
these instructions for upgrading the Alteon Application Switch:
1. Download the new Alteon Application Switch Operating System 24.0 image into the image2
slot.
>> Main# /boot/gtimg 2
Enter hostname or IP address of FTP/TFTP server: <IP
or server name>
Enter name of file on FTP/TFTP server: <image file
name>
Enter username for FTP server or hit return for TFTP
server: <username>
Enter password for username on FTP server: <password>

<software download begins>

2. .After the software download is complete, there is confirmation for using the new image and
switch reboot.
Image download complete (3931913 bytes).
Writing to flash...This takes about 60 seconds.
Please wait
Write complete (3931913 bytes), now verifying FLASH...
Verification of new image2 in FLASH successful.
image2 now contains Software Version 24.1.0.0
Switch is currently set to boot image1.
Do you want to change that to the new image2? [y/n]y
Next boot will use new image2.
Do you want to reboot the switch? [y/n] y
Reset will use software "image2" and the active config block.
>> Note that this will restart the Spanning Tree,
>> which will likely cause an interruption in network
service.

Confirm reset [y/n]: y

Note: Although a switch reboot is depicted in the above example, it is not necessary to reboot the
switch to store the software image. The switch does not use the new software image until the
switch is rebooted.

Page 8
Radware Alteon: 24.1 Release Notes

3. Download the new Alteon Application Switch Operating System 24.0 image into the image1
slot.
>> Main# /boot/gtimg 1
Enter hostname or IP address of FTP/TFTP server: <IP
or server name>
Enter name of file on FTP/TFTP server: <image file
name>
Enter username for FTP server or hit return for TFTP
server: <username>
Enter password for username on FTP server: <password>

<software download begins>

Note: When the Alteon Application Switch Operating System 24.0 (or later) images are mixed
with images prior to 24.0 in the flash (that is, one in image1 and the other in image2), it is
important to save the crash dump of the image that crashed before switching to the other image
should a failure occur. This is because Alteon Application Switch Operating System images later
than 22.0 use a different flash location for the crash dump.

4. After the software download is complete, there is confirmation for using the new image and
switch reboot.

Image download complete (3931913 bytes).


Writing to flash...This takes about 60 seconds.
Please wait
Write complete (3931913 bytes), now verifying
FLASH...
Verification of new image1 in FLASH successful.
image1 now contains Software Version 24.1.0.0
Switch is currently set to boot image2.
Do you want to change that to the new image1? [y/n] y

Next boot will use new image1.


Do you want to reboot the switch? [y/n] y
Reset will use software "image1" and the active
config block.

>> Note that this will restart the Spanning Tree,


>> which will likely cause an interruption in network
service.
Confirm reset [y/n]: y

Note: It is important to reboot the switch to use the new software image.

Page 9
Radware Alteon: 24.1 Release Notes

5. Upgrade the switch boot image. The switch boot image needs to match the new software image.
>> Main# /boot/gtimg boot
Enter hostname or IP address of FTP/TFTP server: <IP
or server name>
Enter name of file on FTP/TFTP server: <image file
name>
Enter username for FTP server or hit return for TFTP
server: <username>
Enter password for username on FTP server: <password>

<software download begins>

6. After the boot image download is complete, the new boot image is automatically applied to the
switch without rebooting.

Upgrading from a version prior to 21.0.4


To download Alteon Application Switch Operating System 24.1.0.0, first perform an intermediary
upgrade to Alteon Application Switch Operating System 21.0.4.0 (or a later version of 21.0.x) into the
image1 slot and then download Alteon Application Switch Operating System 24.1.0.0 into the image2
slot. After this is completed, the switch can be set to reboot from image2 in order to load Alteon
Application Switch Operating System 24.1.0.0

Note: As an alternative, perform a serial download of the Alteon Application Switch Operating System
24.1.0.0 binary image file directly into the image1 slot.

1. Download Alteon Application Switch Operating System 21.0.4 (or a later version of the 21.0.x
software) into the image1 slot.

Alteon Application Switch Operating System 21.0.4 or later software permits a software image
greater than 3 MB to be downloaded into the image2 slot only.

>> Main# /boot/gtimg 1


Enter hostname or IP address of TFTP server: <IP or server name>
Enter name of file on TFTP server: <21.0.4 or later file name>
<software download begins>
. . . . . . .

2. Select image1 for the next reboot and reset the switch.
>> Boot Options# image 1
>> Boot Options# reset

The switch should now boot with the Alteon Application Switch Operating System version
downloaded in step 1.

Page 10
Radware Alteon: 24.1 Release Notes

3. In the boot options menu, download the new Alteon Application Switch Operating System
24.1.0.0 image into the image2 slot.
>> Main# /boot/gtimg 2
Enter hostname or IP address of TFTP server: <IP or
server name>
Enter name of file on TFTP server: <image file name>
<software download begins>
. . . . . . .

4. Select image2 for the next reboot and reset the switch.
>> Boot Options# image 2
Next boot will use switch software image1
instead of image2
>> Boot Options# reset

5. Verify that Alteon Application Switch Operating System 24.1.0.0 has been properly installed
into image2.

6. Download the new Alteon Application Switch Operating System 24.1.0.0 image into the image1
slot.
>> Main# /boot/gtimg 1
Enter hostname or IP address of FTP/TFTP server: <IP
or server name>
Enter name of file on FTP/TFTP server: <image file name>
Enter username for FTP server or hit return for TFTP
server: <username>
Enter password for username on FTP server: <password>

<software download begins>

Note: When the Alteon Application Switch Operating System 24.1.0.0 (or later) images are
mixed with images prior to 24.1.0.0 in the flash (that is, one in image1 and the other in image2),
it is important to save the crash dump of the image that crashed before switching to the other
image should a failure occur. This is because Alteon Application Switch Operating System
images later than 22.0 use a different flash location for the crash dump.

Page 11
Radware Alteon: 24.1 Release Notes

7. When the software download completes, the switch will confirm that the new image is to be used
and asks whether the switch should be rebooted
Image download complete (3931913 bytes).
Writing to flash...This takes about 60 seconds.
Please wait
Write complete (3931913 bytes), now verifying
FLASH...
Verification of new image1 in FLASH successful.
image1 now contains Software Version 250
Switch is currently set to boot image2.
Do you want to change that to the new image1? [y/n]
y
Next boot will use new image1.
Do you want to reboot the switch? [y/n] y
Reset will use software "image1" and the active
config block.
>> Note that this will restart the Spanning Tree,
>> which will likely cause an interruption in network
service.
Confirm reset [y/n]: y

8. Upgrade the switch boot image to match the new software image.
>> Main# /boot/gtimg boot
Enter hostname or IP address of FTP/TFTP server: <IP
or server name>
Enter name of file on FTP/TFTP server: <image file
name>
Enter username for FTP server or hit return for TFTP
server: <username>
Enter password for username on FTP server: <password>
<software download begins>

9. When the boot image download completes, the new boot image is automatically applied to the
switch without the need for a reboot.

Installation Considerations
Radware recommends that you upgrade from software version 22.x to 23.x before you upgrade to
software version 24.0.0.0 This assures maximum configuration compatibility when upgrading from a
previous release of software to version 24.0.

The following should be considered when upgrading the switch software to version 24.0:

 Due to potential boot image incompatibilities, both the boot and software image should be
upgraded when upgrading to the current version of the Alteon Application Switch Operating
System.

Page 12
Radware Alteon: 24.1 Release Notes

Likewise, when downgrading to an earlier version of the software from the current version,
downgrade both the boot and software image.

 After upgrading to the current version of the Alteon Application Switch Operating System, any
ports in disabled VLANs will not link up.

© 2009 Radware, Ltd. All Rights Reserved. Radware and all other Radware product and service names are registered
trademarks of Radware in the U.S. and other countries. All other trademarks and names are the property of their respective
owners. Printed in the U.S.A.

i
Dot3internalmactransit errors were fixed and verified for many scenarios, but due to the many possible configurations,
Radware recommends testing the bug fix for your specific environment.

Page 13

You might also like