You are on page 1of 3

ELECTRICAL INTEGRITY

HRT2MDB PROTOCOL CONVERTER


Hart over 4-20mA to Modbus RTU RS-232 or RS-485 protocol converter.

DESCRIPTION

The HRT2MDB Protocol Converter allows the connection of


smart ield instruments that use HART protocol over 4-20mA
to monitor and control equipments that use Modbus RTU
protocol.

The device periodically adquires the four dynamic variables


or up to eight of the device variables of the HART instrument
and provides them through the Modbus RTU protocol to the
master equipment.

In addition, the device can operate as a HART modem,


allowing direct connection from the PC or Notebook to the
HART instrument. In this way, coniguration or maintenance
tasks don’t require a dedicated handheld device.

FEATURES

OPERATION MODES
The HRT2MDB provides two modes of operation: HART Concentrator and HART Modem.

- HART Concentrator:

Operating as HART Concentrador, the device


periodically adquires (1 sec) the four dynamic
variables or up to eight device variables from
any smart instrument compatible with the
HART protocol over 4-20 mA (low meters,
pressure transmiters, level, position, tempera-
ture).

The adquired data are saved as Modbus registers


to be polled by the master Modbus system (RTU,
PLC, PC, radio linked to SCADA system).

- HART Modem: HRT2MDB protocol converter operation modes.

Operating as HART modem, the device allows the direct connection of the HART instrument through the
serial port of the PC or Notebook for its maintenance. Using the PACTware® coniguration software or similar
application, without the need of a handheld device.

Gie S.A. | www.giemdp.com.ar | January 2011 http://hartmodbus.giemdp.com.ar


ELECTRICAL INTEGRITY

FEATURES

CONFIGURATION SOFTWARE
The HRT2MDB provides a Windows™ application
for the quick and easy coniguration of all the
parameters.

- HART Configuration
- Instrument address.
- Poll: dynamic or device variables.
- Quantity of device variables to poll.
- Code of the device variables to poll.
- Modbus Configuration
- Communication: address, baud rate, parity, stop
bits.
- Floating registers format: standard LSW or
swapped MSW.
- Default value for the loating registers.

The application also allows to monitor the polled


variables, with its unit codes, the data of the
Converter configuration software.
converter and the HART instrument status.

MODBUS PORT
+
POWER
-
The port handles standard Modbus RTU protocol serial
9-30V
HART INSTRUMENT
channel.
COM
El conversor de protocolo puede proveerse con puerto
HRT2MDB Rs serie RS-232 o RS-485.
HIN

Standard option.
HART PORT

+ The port uses the standard HART protocol over 4-20mA


POWER
9-30V - loop current, with FSK Bell 1200-2200 bps modulation.
HART INSTRUMENT

COM The HRT2MDB can be provided with an integrated sense


HRT2MDB
HIN
resistor (250 Ohms, 3W, 1%).

Integrated sense resistor option. The HRT2MDB can be requested with an isolated power
HART INSTRUMENT source of 24V@24mA for the HART instrument or loop
HIN
COM current excitation.
HRT2MDB Rs
HIN
POWER SUPPLY
Isolated 24V@24mA power source option.
The HRT2MDB accepts a wide range of input voltage,
HART Port options. from 9 to 30Vdc.
GIE S.A.
Te/Fax: (+54-223) 482-2308
Galicia 52 – Mar del Plata – Argentina
Gie S.A. | www.giemdp.com.ar | January 2011 www.giemdp.com.ar
http://hartmodbus.giemdp.com.ar
ELECTRICAL INTEGRITY

SPECIFICATIONS ORDERING INFORMATION

Power Supply 9-30 Vdc HRT2MD


T2MDB-RS
RS232
232
Standard converter with RS232 Modbus Port.
Current 100mA @9Vdc
250mA @9Vdc (H24V Option) HRT2MD
T2MDB-RS
RS485
485
Standard converter with RS485 Modbus Port.
Protections Overvoltage: MOV 30V
Overcurrent: 1A Fuse HRT2MD
2MDB-RS232-250
S232-250 / HRT2MD
2MDB-RS485-25
S485-250
Converter with integrated sense resistor.
Temperature -40°C - 85°C
Range HRT2MD
T2MDB-RS
RS232-H24
232-H24V / HRT2MD
T2MDB-R
-RS485-
485-H24
24V

Relative 5% - 95% (non-condensing) Converter with isolated power source of 24V@24mA.


Humidity HRT2MD
T2MDB-RS
RS232-250-H24
232-250-H24V / HRT2MD
H T2MDB-R
-RS485-250-
485-250-H24
24V

Modbus Port ESD protection: >15KV Converter with integrated sense resistor and isolated
(RS232 or R-485) power source of 24V@24mA.
Each order is provided with one configuration / modem
Hart Port Isolation: 3KVdc serial cable (DB9 - MiniDin4) and a CD with manuals and
Overvoltage: TVS 24V PC configuration software.

Indicators 4 dual leds, port status ELECTROMAGNETIC COMPATIBILITY


and TX/RX traffic

IEC 61000-6-4 Radiated electromagnetic field emisions.


Power Supply Isolation: 3KVdc (Acording to CISPR 16-2-3)
24V@24mA Overvoltage: TVS 24V
(H24V Option) Shortcircuit: 42mA continuous IEC 61000-6-2 Radiated electromagnetic field immunity.
(Acording to IEC 61000-4-3)

DIMENSIONS

Gie S.A. | www.giemdp.com.ar | January 2011 http://hartmodbus.giemdp.com.ar

You might also like