given
FCU = 300 kg/cm2 g c
= 1.5
Fy = 4200 kg/cm2 g s
= 1.15
Mu = 3 m.t
Qu = 9.5 t
d (depth) = 29.5 cm 34.5 cm
b (width) = 15 cm

design for moment


Ru = Mu/bd2 22.98190175237 kg/cm2 15 cm

m 0.0069511 >Umin and <Umax


As = m*b*d 3.07586992813004 cm2

f 16 mm use 2 f 16

design for shear


qu = Qu/bd = 21.4689265536723 kg/cm2
q u max = 2.2 fcu/gc 31.1126983722081 kg/cm2
quc = 0.75 fcu/gc 10.6066017177982 kg/cm2 fy = 2400 kg/cm2
S(spacing) = 15 cm
qus = qu-0.5quc= 16.1656256947732 kg/cm2 branches= 2 br
qus.S.b = AS.FY/gC As = 0.87 cm2
m = AS/bd 0.001969329401376
mmin = 4/fy 0.001666666666667 Umin<U use 7 6
kg/cm2

/m
f As As
6 0.28 0.28
8 0.50 0.50
10 0.79 0.79
12 1.13 1.13
14 1.54 1.54
16 2.01 2.01
18 2.54 2.55
20 3.14 3.14
22 3.80 3.80
24 4.52 4.53
26 5.31 5.31
Issue: Design Page
Design of Concrete Beam According to ECP 203-2007 Date: 12/24/2007
1 of 1
Designed by: Tamer El-Najjar
Project:
Checked by: Tamer El-Najjar ECP 203-2007

Material Properties: Limitations on Section (Depends only on material Properties):


FCU 300 c b /d c max /d a max /d m max
R max m min
R min
Fy, Fyst 4200 0.6216 0.4144 0.3315 0.0122 37.06 0.0015 5.37

*The compatibility of strain conditions used to determine cb/d (ECP 203-2007 (4-2-1-1))
*cmax/d calculated as 0.67 cb/d (ECP 203-2007 (4-2-1-2-c))
*amax/d calculated as 0.8 cmax/d (ECP 203-2007 (4-2-1-1-9))
*m max is calculated according to Equ.(4-5) (ECP 203-2007)
*R max is calculated according to Equ.(4-1) (ECP 203-2007)
*m min is calculated according to (ECP 203-2007 (4-2-1-2-i))
*R min is calculated according to Equ.(4-1) (ECP 203-2007)

Relation Between m and R:


m 0.000 0.001 0.002 0.004 0.006 0.008 0.010 0.012 0.014 0.016
Ru 0.00 3.60 7.11 13.81 20.12 26.03 31.54 36.66 41.38 45.69

*Equ.(4-1) & Equ.(4-2) of (ECP 203-2007) are used to establish the relation bet. m & R

R=ηs ×μ−0 . 5×
2
ηs
ηc
μ2 μ=
1± 1−2×
√ ηs
ηc

ηc

Relation Bet. m and R

50.00

45.00

40.00
1
35.00

30.00
R
25.00

20.00

15.00

10.00

5.00 1
0.00
0.0000 0.0020 0.0040 0.0060 0.0080 0.0100 0.0120 0.0140 0.0160 0.0180
m

Straining Actions at Critical Section : Section Dimensions :


Mu Qu M tu B(cm) t(cm) d' (cm)
25.54 25.54 0.00 100.00 60.00 5.00

*The critical section for shear is determined accoding to (ECP 203-2007 (4-2-2-1-1))

Results:
Ru m As required Diam. No. As choosen 60.00
8.44 0.0024 13.14 20 5 15.71 As 15.71

100.00
Issue: Design Page
Design of Concrete Beam According to ECP 203-2007 Date: 12/24/2007
1 of 1
Designed by: Tamer El-Najjar
Project:
Checked by: Tamer El-Najjar ECP 203-2007

Section Properties: Shear Stresses:


A shear A oh A0 ph te qu q tu
5500.00 4500.00 3825 280.000 16.07 4.64 0.00

Nominal Ultimate Shear Strength for Concrete (kg/cm2): qcu 10.61


The limit after whitch qtu must be considered (kg/cm2): 2.69

Maximum Allowble Shear Stress (kg/cm2): qumax 31.11


Shear Stresses which to be resisted by reinforcement: qsu 0.00

*The section properties Aoh, A0, ph, te is determined accoding to (ECP 203-2007 (4-2-3-2))
*qu,qtu is determined accoding to Equ.(4-13) & Equ.(4-47) (ECP 203-2007)
*qcu is determined accoding to Equ.(4-18) (ECP 203-2007 )
*qumax is determined accoding to Equ.(4-16) (ECP 203-2007 )
*The limit after whitch qtu must be considered is determined accoding to Equ.(4-17) (ECP 203-2007 )

Evaluation of Sec. Dimensions in Resisting Shear Stresses:


*The Section Dimensions are adequate because qu < Equ.(4-16) (ECP 203-2007)
*The Section Dimensions are adequate because Equ.(4-48) < Equ.(4-16) (ECP 203-2007)

Evaluation of the required shear reinforcement :

f cu f cu
qtu  0.19 kg/cm2 qtu  0.19 kg/cm2
c c

˱Ύ
ϘΒσκ Ϙϟ΍
΢ ϴϠ δΗ ΐ Ϡμ ϟΔΒδϧϰϧΩ΃ ΔϣϭΎ
ϘϤϟ΢ ϴ
ϠδΗ
qu  qcu ) 6 -1 -2 -2 -4(ΪϨΒϠ
ϟ q tu

ΔϣϭΎ
ϘϤϟ΢ ϴ
ϠδΗ
ΔϣϭΎ
ϘϤϟ΢ ϴ
ϠδΗ
qu  qcu (q u - q cu /2)
q tu
(q u - q cu /2)

*No need for using shear reinforcement, so use minimum stirrups

Rft. required to resist qsu :


m min
(%) 0.00100

m st
(%) 0.00000
No. of branches 5

f 6
Ast 1.41
Ast for one branch 0.28
Spacing bet. Ties (cm) #DIV/0!

Rft. required to resist qtu :


Astr #DIV/0!
Spacing bet. Ties (cm) #DIV/0!

Total Web Rft. :


Area of branch No. of branches f
Outside Branches (Astr + Ast/branch) #DIV/0! 2 #DIV/0!
Internal Branches Ast 0.28 3 6