You are on page 1of 8

Halton - Ecology-E

Electrostatic Precipitator with Automatic Cleaning


Ventilation is the critical factor to
consider when investigating the
feasibility of a new commercial
Key Features
kitchen site. New projects, new
designs to existing buildings, • New Generation ESP designed for dependable operation
and non-traditional sites often
require uncommon solutions • Reliable high frequency electronics do not use fragile ionizing
for kitchen ventilation problems. wires or insulators
Ecology-E may be your solution
to: • Specified efficiency is instant and constant

• Code requirements • Pressure drop is a constant 0.25” w.g., resulting in reduced


• Environmental standards fan horsepower
• Multi-story structures
• High installation costs • Constant resistance to airflow prevents fluctuations in system
• Limited roof top space air volume
• Historical/Architectural sites
• Multi-restaurant applications • Permanent aluminum collector cells never need replacing

• Built-in automatic cleaning and PLC controls


Halton has the equipment,
design flexibility and experience • Optional bonded carbon for gas/odor control
to solve the problems of each
site. • Optional custom blower/motor package

• Optional safety filter

Halton Ecology-E
Electronic Air Cleaning
Halton’s Ecology-E is a new generation electrostatic precipitator used to extract cooking effluents and odors
from commercial kitchen exhaust. Ecology-E is a reliable solution for minimizing the restaurants impact on
the surrounding environment. It’s available in side access units for use with central air handlers or as a stand
alone fan powered unit.

PRE-FILTER COLLECTOR CLEAN AIR


DIRTY AIR IONIZER

Dependable high frequency electronics, safe/no-short charging system, rugged ionizer electrodes and
improved automatic cleaning are just a few of the innovations developed to make Ecology-E the most
reliable ESP ever. High efficiency particle collection is delivered instantly and continuously. The extremely
low resistance to airflow means less fan horsepower is needed, compared to conventional media filtration,
and since resistance to airflow is constant, the system air volume is always maintained. Optional bonded
activated carbon can be added for odor control, making Ecology-E the IDEAL SOLUTION for ventilation or
exhaust air quality problems.

Reliability, high performance and low operating cost make Ecology-E an excellent choice for indoor air cleaning
or exhaust air pollution control.

Halton Ecology-E
Ecology-E Delivers
Performance
Ecology-E uses a 2-stage electronic collector for The versatile control system can be easily integrated
Particulate control. A high-density, low power first with existing process systems, adding another degree
stage charges each particle. The charged particles then of reliability in the overall system operation.
travel downstream into the second stage where they
are repelled from the air stream, captured, and retained The durable, all aluminum 2-stage electronic collectors
on collector plates. feature unitary construction and are designed to last the
The electronic collector uses an airfoil design that lifetime of the system. The integrated automatic wash
eliminates air-bypass, so all of the system air and system assures optimum performance and maximum
airborne particulate pass directly through the charging system reliability.
and collecting stages. This assures that all contaminated
air is treated.
Ecology-E delivers the rated efficiency instantly and
continuously. The high-density charging and collecting
zones produce an immediate and constant removal rate
regardless of particle size.

PowerClean
100 0.5

95 0.4
MIL
-ST
D-2
Resistance (in. w.g.)

82
Efficiency (%)

90 0.3

85 0.2
ce*
Value
stan
Resi
Ecology-E’s design features increased collector surface
80 0.1 area in a smaller package compared to conventional
systems, resulting in higher dirt holding capacities and
* Includes prefilters
and mist eliminators
reduced system footprint. This translates into extra
75 0 available floor space, up to 30% in some instances.
350 400 450 500 550 600 Ecology-E’s low resistance to airflow results in reduced
Airflow (fpm) fan horsepower and fan energy cost. Over time, this
reduction amounts to significant energy savings. Since
Ecology-E uses wash-in-place electronic collectors,
replacement filter cost, disposal cost and labor cost are
eliminated. When it comes to value, Ecology-E delivers.
Reliability High performance and reliability in a compact design,
Ecology-E uses a programmable logic controller (PLC) for and low operating cost make Ecology-E the ideal choice
system control and monitoring, in conjunction with high for today’s industrial air quality problems. Call us, and
frequency electronics, to deliver optimum performance we’ll help evaluate your application.
and assure the highest degree of reliability.

Halton Ecology-E
Ecology-E (HE) Components

System PLC Control

Detergent

Model HE-0604-W
(Metal mesh mist eliminators removed) System Accessories
High Voltage Power (solenoid valve, backflow preventer)

System Description System Accessories


Ecology-E Side Access Model (HE) is a factory packaged Each Ecology-E Model HE is furnished with the
system including side access housing with upstream following standard accessories.
and downstream flanges, integral wash system, pre Pressure gage ...............................................1 each
and post mist eliminators, electronic collectors, system Wash water strainer ......................................1 each
control, detergent dispenser, and accessories. The factory Ball valve .......................................................1 each
assembled system is designed for mating to air handlers Backflow preventer ........................................1 each
and ventilation systems or as a stand alone unit factory Solenoid valve ................................................1 each
furnished blower/motor package. Detergent .......................................................55 gal
The System PLC Control is programmed to start and
stop the system according to customer requirements.
Utilities
At a predetermined schedule, the Control also initiates Electrical: Standard: 120 Vac, 1 Ph, 60 Hz
a water/detergent wash cycle to clean away collected Optional: 208 - 230 Vac, 1 Ph, 50/60 Hz
contaminants. Spent wash water is drained from the Wash Water: (See Selection Table) gpm @ 50 psig
bottom drain pan, Ecology-E is forced dried and ready to
System Drain: Integral 3” FNPT
continue operations. Start, stop and wash functions can
also be initiated by manual push button. Options
Blower Transitions, plenums and steel channel support base
SafetyFilter
are furnished to the customers specifications.
Odor/Gas Phase Control: Bonded, activated carbon
panels are furnished to remove a broad range of
both base and acid gases. Panels are held in place
by gasketed, extruded aluminum tracks arranged in
a Vee bank configuration.
Blower: Custom blower/motor and motor starter
Base
Motor combinations are available in a variety of sizes
Starter
Transition
Activated and styles to meet system air volume and static
Carbon
ESP resistance requirements.

Halton Ecology-E
Ecology-E (HE) Size Selection Table
Air Volume (cfm) Dimension (in) Wash Cycle
Model Wt (lb)
95% Width Height Length Water (gpm) Detergent (gal)
HE-0202-W 1250 31.13 46.31 196 4.8 .48 2,700
HE0203-W 2000 41.86 46.31 196 7.2 .72 3,100
HE-0204-W 2500 54.38 46.31 196 9.6 .96 3,600
HE-0205-W 3500 65.13 46.31 196 12.0 1.20 4,000
HE-0206-W 4000 76.00 46.31 196 14.4 1.44 4,100
HE-0402-W 2500 31.13 70.19 224 9.6 .96 3,500
HE0403-W 4000 41.86 70.19 224 14.4 1.44 4,000
HE-0404-W 5500 54.38 70.19 224 19.2 1.92 4,600
HE-0405-W 6500 65.13 70.19 224 24.0 2.40 5,200
HE-0406-W 8000 76.00 70.19 224 28.8 2.88 5,700
HE-0407-W 9000 88.63 70.19 224 33.6 3.36 6,400
HE-0408-W 10,500 99.38 70.19 224 38.4 3.84 7,000
HE-0409-W 12,000 110.13 70.19 224 43.2 4.32 7,600
HE-0602-W 4000 31.13 94.04 240 14.4 1.44 4,600
HE-0603-W 6000 41.86 94.04 240 21.6 2.16 5,200
HE-0604-W 8000 54.38 94.04 240 28.8 2.88 6,100
HE-0605-W 10,000 65.13 94.04 240 36.0 3.60 6,800
HE-0606-W 12,000 76.00 94.04 240 43.2 4.32 7,300
HE-0607-W 14,000 88.63 94.04 240 50.4 5.04 8,300
HE-0608-W 16,000 99.38 94.04 240 57.6 5.76 8,800
HE-0609-W 18,000 110.13 94.04 240 64.8 6.48 9,500
HE-0610-W 20,000 122.69 94.04 240 72.0 7.20 10,200
HE-0802-W 5000 31.13 119.94 258 19.2 1.92 5,000
HE-0803-W 8000 41.86 119.94 258 28.8 2.88 5,700
HE-0804-W 11,000 54.38 119.94 258 38.4 3.84 6,700
HE-0805-W 13,000 65.13 119.94 258 48.0 4.80 7,450
HE-0806-W 16,000 76.00 119.94 258 57.6 5.76 8,000
HE-0807-W 18,000 88.63 119.94 258 67.2 6.72 9,100
HE-0808-W 21,000 99.38 119.94 258 76.8 7.68 9,650
HE-0809-W 24,000 110.13 119.94 258 86.4 8.64 10,500

(1) Based on 50 psi water pressure. Typical wash cycle is 4 mins.


(2) Total system net weight

Model Number Development Unit Selection Guide


Standard 1. From the Size Selection Table below, select the
Model HE with Air Volume and Dimensions that
HE 02 03 W meet the required efficiency and arrangement.
Side Access 2 ft. High 3 ft. Wide Wash 2. Two Model HE units of the same height may be
Nominal Nominal System arranged side-by-side to create a larger, multi-section
Optional Features unit. Specify one unit with left hand and one unit
with right hand access doors.
SF C B 3. Each Model HE is shipped complete with the Power
Safety Activated Blower/ Pack, System Control, Detergent Dispenser and
Filter Carbon Motor System Accessories as shown on Page 5.

Halton Ecology-E
Ecology-E (HE) Size Selection Table
General Control and High Voltage Power
The electrostatic precipitator (ESP) shall be the two Supplies
stage, dual voltage, plate type, sized to clean the airflow
The System Control shall be the programmable logic
capacities scheduled on the Contract Documents at an
(PLC) type, furnished in a NEMA 3R enclosure, pre
efficiency of (specify %) when tested per MIL-STD- 282,
programmed to sequence the ESP through wash cycles
DOP Smoke Penetration Method.
at a schedule to be determined with the Owner. Integral
electronic time clock with manual override shall be
Configuration provided.

The ESP shall be furnished in a side access housing, High voltage power supply, furnished in a NEMA 1
fabricated from 14 gage galvannealed steel, continuous enclosure, shall be the high frequency, solid state type,
welded, primed and painted. The housing shall be supplying a dual voltage and current output specified
furnished with gasketed, hinged access door, flanged by the ESP manufacturer. Power supply shall have a
inlet outlet collars and sloped bottom drain pan. The regulated input and output for line fluctuations of 10%
housing shall be tracked for and furnished with aluminum and shall have a current limiting shutdown and restart
pre and post mist eliminators. feature.

Ionizer-Collector Cells The face panel of the enclosures shall contain indicators
for electronic air cleaner control status (run, wash, etc.),
Ionizing-collecting cells shall be of industrial design individual power supply, primary circuit indicating light,
integrity and single unit construction. The cells shall be monitoring instrumentation, and on-off switch.
all aluminum construction except the ionizing electrode
shall be of the rigid stainless steel type. Repelling and
collecting plates shall be positively retained in place
Electrical Interlocks
using tie rod and tubular spacer design. High voltage All access to ESP and high voltage power packs shall
insulators shall be molded from structural, self-glazing contain electrical safety interlocks which de-energize the
ceramic; shall contain no appurtenances; shall be of primary power circuit prior to accessing high voltage.
radial and bilateral symmetry; and shall contain no high
voltage penetrations.
Optional
Built-in Cleaning System Blower/motor, motor starter, channel iron hang base
and odor control custom selected to meet individual
Detergent, wash and rinse water shall be applied by requirements.
oscillating copper manifolds containing brass spray
nozzles, located on both the air entering and air leaving
side of each cell tier. Complete, effective washing of
all ionizing-collector cell surfaces and all appurtenances
shall be provided. Drive motors, used to oscillate the
manifolds, shall be high torque, gear reduced, totally
enclosed fan cooled type, and be permanently lubricated.
Drive linkage shall be the rigid, positively fastened type
without tracks or sprockets. A detergent dispenser
assembly shall be provided and shall consist of a (specify
30, 55 or 100) gallon anticorrosive reservoir, positive
displacement pump, motor, and flow volume control
valve, Solenoid valve, strainer, backflow preventer, ball
valve, pressure gage and an initial supply of detergent Each Ecology-E Side Access system is ETL listed,
conforming to ANSI/UL STD 867 & UL STD 710.
shall be furnished by the ESP manufacturer.

Halton Ecology-E
U.S.
Halton Company
101 Industrial Drive,
Scottsville, KY 42164
Tel: (270) 237-5600
Fax: (270) 237-5700
Website: www.haltoncompany.com

Canada
Halton Indoor Climate Systems, Ltd.
1021 Brevik Place,
Mississauga, ON L4W 3R7
Tel: (905) 624-0301
Fax: (905) 624-5547
Website: www.haltoncanada.com

You might also like