CARRIER GRADE PERFORMANCE UTILITY GRADE RELIABILITY LOWEST TOTAL COST OF OWNERSHIP

Product Catalog

Our Company
RuggedCom designs and manufactures rugged communications equipment for harsh environments. Founded by people with strong backgrounds in electric utility and industrial automation, we at RuggedCom have a first hand understanding of the needs and issues faced by our customers. This is reflected in RuggedComs industry leadership in pioneering technologies and products which offered the worlds first IEC 61850-3 compliant Ethernet switch suitable for electric utility substation environments, the worlds first IEEE 1613 Class 2 error free communications devices, the worlds fastest network fault recovery, and the worlds first fully managed IP67 rated Ethernet switch. Other industry specific innovations have made our products the product of choice for high-reliability, high-availability, mission critical communications networks deployed in harsh environments around the world. Our corporate headquarters are located in Concord, Ontario, Canada with regional offices worldwide. RuggedCom sales representatives and distributors can be found in over 25 countries around the world to provide knowledgeable and timely support.

Our Products
RuggedCom products provide a level of ruggedness and reliability that have set the standard for rugged communications networks deployed in harsh environments. RuggedCom products offer extreme temperature (-40C to +85C) immunity, IP67 rated ingress pollution protection allowing immersion in water, Zero-Packet-Loss technology for immunity to high levels of electromagnetic interference, and enhanced rapid spanning tree (eRSTP) performance for ultra high-speed network fault recovery. RuggedCom products can be found in mission critical networks used in: substation automation; smart, self-healing, power grids or Smart Grid systems; intelligent transportation systems for traffic management and railway control systems; and in process control and manufacturing automation systems used across multiple industrial sectors. RuggedCom products are at their best when the environment around them is at its worst. Our faith in our product reliability is demonstrated by providing a standard 5 year warranty on all RuggedCom products.

RuggedCom Product Catalogue

Software

RuggedRated for Reliability in Harsh Environments


EMI Immunity per IEEE 1613 & IEC 61850-3 Zero-packet-loss under EMI stress (KEMA tested) IEEE 1613 Class 2 performance (KEMA tested) Extended Temperature: -40 to 85C(no fans) High reliability: MTBF > 1,000,000 hours High availability: >99.9999% Dual Redundant Power Supplies Integrated Cyber Security Features NERC CIP Precision Time Sync: <1s Support for Protection & Control applications Support for: AMI, DA, DMS, EMS, SCADA & IT Exceeds NEMA TS 2 Long Haul Fiber Support Fast Network Fault Recovery (<5ms with eRSTP) Integrated Power Supplies (Optional Dual Redundancy) Advanced Layer 2/3 Networking IP66 / 67 Rated Products (Waterproof/Dustproof) High EMI Immunity exceeds IEC 61000-6-2 and IEC 61800-3 Heavy Duty Construction Resilient to Vibrations and Shock IDS capability Integrated Router/Firewall/VPN Stateful Firewall with NAT Full IPSEC Virtual Private Networking

OpenHouse

Professional Services
Consulting Training Support
Highly Skilled Consultants Network Design & Implementation Professional Trainers Full Set of Training Courses 24x7x365 Technical Action Center Highly Skilled Multilingual Customer Support

RuggedCom Precision Time Solution


IEEE 1588 version 2 precision timing IEEE 1588 to IRIG-B conversion GPS clock input supporting Grandmaster Clock mode Transparent Clock Mode and Multiple clock source inputs

www.RuggedCom.com

Electric Power

Transportation

Utility Grade Products for the Substation Environment


RuggedCom has the Industrys most complete basket of Ethernet networking devices designed specifically for the substation environment. Trends in electric utility automation, specifically substation automation, have converged upon a common communications architecture with the goal of having interoperability between a variety of Intelligent Electronic Devices found in the substation. The resulting standard that emerged is known as the Utility Communications Architecture 2.0 (UCA2.0) and is now becoming an international standard as IEC 61850. The following network architecture illustrates the range of products available in the context of an IEC 61850 substation. Other network architecture such as ring or star topologies, or a hybrid topology, are also easily accommodated.
SCADA WAN

Intelligent Transportation Systems


RuggedCom offers a variety of rugged communications solutions for the transportation industry. Our products are used in:
Intelligent Transportation Systems (ITS) for projects
implementing Advanced Traffic Management Systems in accordance with NTCIP requiring C2F and C2C communications. applications utilizing EN 50121-4 compliant Rail Ethernet networks installed in wayside cabinets for control, signaling and video monitoring applications. Center-to-field (C2F) Communications: A traffic signal management system communicating with traffic signal controllers at intersections, monitoring devices, passenger information signs on transit vehicles, transit stations and stops. Center-to-Center (C2C) Communications: Two or more traffic signal management systems exchanging information to achieve coordinated operation of traffic signals managed by the different systems and to enable personnel at one center to monitor the status of signals operated from another center.

NERC CIP Cyber Security IEC 61850-8-1 Station Bus


RuggedRouter Cyber Security Appliance RuggedSwitch Ethernet Switches
Ethernet Switch RuggedSwitch - RSG2100

Ethernet Switch RuggedSwitch - RS900

Ethernet Switch RuggedSwitch - RS900

RuggedServer Serial Device Servers RuggedMC Media Converters

100/1000 Mbps Fault Tolerant Fiber Optical Ethernet Ring

IEC 61850-9-2 Process Bus

RuggedSwitch Ethernet Switches

Serial Device Server RuggedServer - RS400

Merging Unit(s)
C

52

A B

Power System
IED = Intelligent Electronic Device

Applications

Industrial

Military

Industrial Ethernet Solutions


Industrial Ethernet on the plant floor has gained mass acceptance across multiple industries. Designed to create a real-time seamless flow of information between the plant floor and the back office, Industrial Ethernet networks are also becoming an integral part of real-time control systems for process control and discrete manufacturing applications. Originally designed to be used in mission critical applications, RuggedComs substation hardened Ethernet Switches offer the industrys highest levels of:
Reliability MTBF > 500,000 Hrs Ruggedness Operating Temperature (-40C to +85C) Immunity Zero-Packet-Loss technology for high EMI Performance Gigabit performance with eRSTP for ultra network fault recovery. Security IEEE 802.1x port based network access control
coupled with Radius password management
Corporate LAN

Cyber Security Features


RuggedCom has the most complete line of substation hardened communication devices with built in cyber security features necessary to comply with the North American Electric Reliability Council (NERC) Critical Infrastructure Protection (CIP) requirements. RuggedCom has been monitoring the developments of the various industry specific security standards including NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS, to ensure all RuggedCom products contain features necessary to comply with the identified requirements. By combining the security features the RuggedSwitch products with that of the RuggedRouter SCADA cyber security appliance, our customers establish an electronic security perimeter around their critical infrastructure preventing the disruption of mission critical applications by accidental or malicious acts.

environments.

high speed (5ms/hop)

Command and Control

Factory Floor
Plant Level Control Level
Router, VPN, Firewall RuggedRouter - RX1000
RuggedSwitch M2200 Ethernet Switch

Ethernet LAN
RuggedSwitch M2100 Ethernet Switch RuggedSwitch M2100 Ethernet Switch

RuggedSwitch RSG2100

RuggedSwitch RSG2200

Device Level

Ethernet LAN

IOU IOU IOU

IOU

IOU IOU IOU

IOU

RuggedSwitch RS900

RuggedSwitch RS969

RuggedMC RMC40

RuggedSwitch RS900G

RuggedMC RMC30

RuggedServer RS400
IOU

RuggedSwitch M969 Ethernet Switch

IOU

IOU IOU

PLCs

Remote I/O

Sensors

DCS

www.RuggedCom.com

Table of Contents

RuggedCom Software
ROS: Rugged Operating System ....................................................................................................................................................... 8 ROX: Rugged Operating System on Linux ....................................................................................................................................... 9 RuggedNMS: Network Management Software .............................................................................................................................. 10 RuggedExplorer: Provision and Configuration Tool ........................................................................................................................11 RuggedPING: High Accuracy Graphical Ping Tool .........................................................................................................................11 RuggedDirector: Serial Port Director ...............................................................................................................................................11 CrossBow: Secure Access Management ....................................................................................................................................... 12 eLAN: Substation Automation Solutions ........................................................................................................................................ 13 ReFlex: HMI-SCADA: Monitoring and Control for Distribution Systems ........................................................................................ 14 OpenHouse: Engineering Asset Management Software................................................................................................................ 15

RuggedMC Media Converters


RMC: Ethernet Media Converter (Copper to Fiber) ........................................................................................................................... 16 RMC20: Serial Media Converter (Copper to Fiber) ........................................................................................................................... 16 RMC40: 4 Port Unmanaged Ethernet Switch and Speed/Media Converter ..................................................................................... 16 RMC41: 2 Port Ethernet Media and Speed Converter ...................................................................................................................... 16

RuggedSwitch Hardened Ethernet Switches


i800, i801, i802 & i803: Compact Managed Industrial Ethernet Switches with Fiber Optics ............................................................ 17 RS900: 9 Port Managed Ethernet Switch with Fiber Optical Uplink Ports ........................................................................................ 18 RS900G: 10 Port Managed Ethernet Switch with Gigabit Uplink Ports ............................................................................................ 18 RS940G: 8 Port Managed Gigabit Ethernet Switch .......................................................................................................................... 18 RS1600: 16 Port Managed Fiber Optical Ethernet Switches............................................................................................................. 19 RS1600F: 16 Port Managed Fiber Optical Ethernet Switches .......................................................................................................... 19 RS1600T: 16 Port Managed Fiber Optical Ethernet Switches ........................................................................................................... 19 RS8000: 8 Port Managed Fiber Optical Ethernet Switch .................................................................................................................. 20 RS8000T: 8 Port Managed Fiber Optical Ethernet Switch ................................................................................................................ 20 RS8000H: 8 Port Managed Fiber Optical Ethernet Switch ............................................................................................................... 20 RS8000A: 8 Port Managed Fiber Optical Ethernet Switch................................................................................................................ 20 RS969: IP66/IP67 Rated 10 Port Managed Ethernet Switch with Gigabit Uplink Ports ................................................................... 23 M969: MIL-STD and IP66/IP67 Rated 10 Port Managed Ethernet Switch with Fiber Uplink Ports .................................................. 23 M2100: 19 Port Modular Managed Ethernet Switch with Gigabit Uplink Ports ................................................................................. 24 M2200: 9 Port Managed Gigabit Ethernet Switch ............................................................................................................................. 24 RSG2100: 19 Port Modular Managed Ethernet Switch with Gigabit Uplink Ports ............................................................................ 26 RSG2100P: 32 Port Managed Ethernet Switch with Integrated Power over Ethernet ...................................................................... 26 RSG2200: 9 Port Managed Gigabit Ethernet Switch ........................................................................................................................ 28 RSG2288: Modular Managed Gigabit Switch with IEEE 1588 v2 and IRIG-B .................................................................................. 28 RSG2300: 32 Port Managed Ethernet Switch with 4 Modular Gigabit Uplink Ports ......................................................................... 30 RSG2300P: 32 Port Managed Ethernet Switch with Integrated Power over Ethernet ...................................................................... 30 RuggedVDSL: RS900L, RS910L, RS920L & RS930L ................................................................................................................... 32

Table of Contents

RuggedAIR: Industrial Hardened Wireless LAN Devices


RS900W: Wireless Ethernet with integrated 8 Port Managed Switch ............................................................................................... 34 RS910W: Wireless Device Server with 2 Serial and/or 2 Ethernet Ports .......................................................................................... 34 RS920W: Wireless Serial Device Server with Ethernet over VDSL Interface................................................................................... 34 RS930W: Wireless Ethernet with integrated 6 Port Managed Switch and Ethernet over VDSL Interface ....................................... 34

RuggedServer: Serial Device Servers


RS910: Serial Device Server with up to 3 Ports Managed Ethernet Switch ..................................................................................... 36 RS400: Serial Device Server with Integrated Fully Managed Ethernet Switch ................................................................................. 36 RS401: Serial Device Server with Integrated 4 Port Managed Ethernet Switch ............................................................................... 36 RS416: Serial Device Server with Integrated 4 port Managed Ethernet Switch with IEEE 1588 v2 and IRIG-B Conversion .......... 38 RS416P: Serial Device Server with Integrated 4 Port Managed Ethernet Switch............................................................................. 38

RuggedBackbone: Integrated Router and Switch


RX1500: Rugged and Modular Hot-Swappable Layer 3 Switch and Router, with optional redundant power supply ....................... 40 RX1501: Rugged and Modular Hot-Swappable Layer 3 Switch and Router ..................................................................................... 40 RX1510: Modular and Hot-Swappable Layer 3 Switch and Router with Optional Redundant Power Supply ................................... 42 RX1511: Compact and Modular Layer 3 Switch and Router, ideal for Pole Mount Applications ....................................................... 42 RX1512: Compact and Modular Layer 3 Switch and Router with Fixed DC Power Supply............................................................... 42 RX5000: Multi-Service Platform ........................................................................................................................................................ 44 MX5000: MIL-STD Multi-Service Platform ........................................................................................................................................ 46 RuggedEnclosure ........................................................................................................................................................................... 48

Cellular Modules
RuggedCell EVDO for RX1000 ...................................................................................................................................................... 49 RuggedCell HSPA for RX1000 ....................................................................................................................................................... 49

RuggedRouter: Cyber Security Appliances


RX1000: Industrially Hardened Cyber Security Appliance ................................................................................................................ 50 RX1000P: Industrially Hardened Cyber Security Appliance ............................................................................................................. 50 RX1100: Advanced Cyber Security Appliance................................................................................................................................... 50 RX1100P: Advanced Cyber Security Appliance ................................................................................................................................ 50

RuggedPower:
RP100: Single Port 802.3at Power over Ethernet Injector ................................................................................................................ 52 RP110: Serial 802.3at Power over Ethernet Injector ......................................................................................................................... 52

RuggedMAX: Wireless WiMax Broadband Technology


WiN5100: Vehicular Subscriber Unit .................................................................................................................................................. 54 WiN5200: Outdoor Subscriber Unit ................................................................................................................................................... 54 WiN7000: High Power Base Station .................................................................................................................................................. 55 WiN7200: Outdoor Base Station ........................................................................................................................................................ 55

www.RuggedCom.com

ROS Features

Cyber security Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and high reliability is of paramount importance. Key ROS features that address security issues at the local area network level include:
1. Passwords - Multi-level user passwords secures switch against unauthorized configuration 2. SSH/SSL - Extends capability of password protection to add 128-bit encryption of passwords and data as they cross the network 3. Enable/Disable Ports - Capability to disable ports so that traffic can not pass 4. 802.1Q VLAN - Provides the ability to logically segregate traffic between predefined ports on switches 5. MAC Based Port Security - The ability to secure ports on a switch so only specific Devices/MAC addresses can communicate via that port 6. 802.1x Port Based Network Access Control - The ability to lock down ports on a switch so that only authorized clients can communicate via this port 7. RADIUS - authentication service using MD5 harsh and providing centralized password management 8. SNMPv3 - encrypted authentication access security and data encryption (CBC-DES with 56- bit encryption key)

Quality of Service (IEEE 802.1p) Some networking applications such as real-time control or VoIP (voice over IP) require predictable arrival times for Ethernet frames. Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. ROS supports Class of Service in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and r e d ucing jitter to allow such demanding applications to operate correctly. VLAN (IEEE 802.1q) Virtual local area networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. Link Aggregation(802.3ad) The link aggregation feature provides the ability to aggregate several Ethernet ports into one logical link (port trunk) with higher bandwidth. IGMP Snooping ROS uses IGMP snooping (Internet Group Management Protocol v1&v2) to intelligently forward or filter multicast traffic streams (e.g. MPEG video) to or from hosts on the network. SNTP SNTP automatically synchronizes the internal clock of all ROS devices on the network. This allows for correlation of time stamped event s for troubleshooting. SCADA

The ROS cyber security features are included to help address the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS. eRSTP RuggedCom eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are pruned to prevent loops. eRSTP yields worst-case fault recovery of 5ms times the bridge diameter and allows rings of up to 160 switches. SNMP (Simple Network Management Protocol) SNMP provides a standardized method for network management stations the ability to interrogate devices from different vendors. SNMP versions supported by ROS are v1, v2c, and v3. 1 eRSTP fault recovery times may be approximated as follows:
1,000 Mbps, fault recovery performance is <5ms/hop For 1,000 Mbps, fault recovery performance is For
<5ms/hop + 20ms

ROS contains features that optimize network performance and simplify switch management based on the unique requirements found in SCADA and industrial automation applications. Port Based Network Access Control ROS supports the IEEE 802.1x standard that defines a mechanism for port-based network access control which provides a means of authenticating and authorizing devices attached to LAN ports.

ROX Features

Port Statistics and RMON ROS provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures.

GOOSE Tunnels The IEC61850 Generic Object Oriented Substation Event (GOOSE) protocol uses Layer 2 multicast frames to distribute its messages and hence, is incapable of operating outside of a switched Ethernet Network. The GOOSE tunnel feature provides a capability to bridge GOOSE frames over a WAN. The RuggedRouter is the only network router on the market that provides intrinsic support for GOOSE Messages. IEEE1588 standard on the PTP card Enables the IEEE 1588 functionality on RuggedComs Precision Time Protocol (PTP) card. This feature compliments the GPS and IRIG-B support. Link Backup (Dial-On-Demand/Dial-Backup/DisasterRecovery over configured interfaces) Automatic failover for wide area networks. This feature provides the ability to designate trunks in main backup relationship, raising the backup trunk on failure of the main trunk and lowering it after recovery. The main links can be TE1or DDS while the backup link is a modem. Many profiles of dialed numbers can exist (each serving as a distinct backup link) Alert System (email/trap alerts) A system that generates alerts, displaying them locally and/ or forward them via email messages and SNMP Traps/ Informs. Active alerts are locally displayed and can be cleared manually. Multiple forwarders can be configured, a configurable filter level controls alert forwarding to each forwarder. Web Help Menus A context sensitive help link has been provided from each web management menu. Following the link loads help for that page. Support DHCP on bridged mode ADSL Customers needing to assign their public interface address from their carrier via DHCP can now do so.

Port Configuration and Status ROS allows individual ports to be hard configured for speed, duplex, auto-negotiation, flow control and more. Loss of Link Management Some intelligent electronic devices (IEDs) have dual fiber optic ports with automatic failover to a backup port should the primary fail. Event Logging and Alarms ROS records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others. Port Mirroring ROS can be configured to duplicate all traffic on one port to a designated mirror port. HTML Web Browser and Telnet User Interface ROS provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via Telnet. Configuration via ASCII Text File All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP or Xmodem. Command Line Interface (CLI) A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades.

www.RuggedCom.com

RuggedNMS Network Management Software

Features
Software

RuggedNMS
RuggedNMS-SW - ____ Size

Key Features
Centralized management and monitoring of network and networked devices to achieve desired level of network availability performance and operational efficiency Common User Interface across the RuggedCom product line Scalable and distributed architecture that can support very large networks Greater network visibility to enable proactive corrective actions and improved capacity utilization Web based UI with graphical network view with highly versatile and configurable auto discovery and polling subsystem

Server Computer
Appliance Min. Server Spec. Dual Pentium server based LINUX or Windows XP desktop computer with a fixed configuration Intel Core 2 Quad-Core CPU 2.4 GHz or higher , 4 GB RAM, 500 GB

RUGGEDNMS-SW - _____ Size PS: Power Supply Supports up to 128 nodes 128 Supports up to 256 nodes 256 1024 Supports up to 1024 nodes MAX Supports over 1024 nodes
Notes: 1. Node is any device with an IP address 2. Software includes 1 year support 3. RuggedNMS is supported on both Debian Linux & Windows XP platforms 4. A 20 node demo version is available for both Debian Linux & Windows XP platforms
Switch Switch

Remote Location
SNMP Agent
Web Server

SNMP Agent

HTTP

Switch

SNMP Agent
Polling Engine Database
T-1 Link

Switch

SNMP Agent
Router

Switch

Central Office

SNMP Agent

Router

SNMP Agent

SNMP Agent

Remote Site
Switch

RTU

Workstation Accessing RuggedNMS via Web Browser

RuggedNMS Server

Router T-1 Link

Switch

IED

Central Office
Router Switch Switch T-1 Link

Switch WorkStation

Remote Site
Switch

RTU

Switch

Workstation Accessing RuggedNMS via Web Browser

Router

Switch

IED

Switch WorkStation

Workstation Accessing RuggedNMS via Web Browser

10

RuggedExplorer, RuggedPING & RuggedDirector

RuggedExplorer is RuggedComs powerful tool to easily provision and configure new and existing ROS based devices. RuggedExplore can run on any LAN based MS Windows PC eliminating the need to connect a serial cable to any of the devices. It built-in file transfer capabilities allow users to easily upload and download files and firmware from one convenient console. Features and Benefits: Discover and Configure RuggedCom ROS devices on
Allows users to detect and configure IP addresses on
non-provisioned or provisioned devices Fast, accurate device discovery Intuitive GUI interface displays all ROS devices and visually identifies duplicate IP addresses Automatically discovers new devices added to the network Availiable configuration parameters Address Contact Name IP Network Mask Default Gateway System Name Location your LAN

RuggedPING is Ruggedcoms new high accuracy graphical ping tool. This handy utility can send ICMP echo message and process. Incoming responses with a granularity of 1ms. Network adminstrators will be able to perform RSTP performance testing, ping sweeps to automatically discovery device and capature outage duration for device with RuggedPING. Features and Benefits: Allows users to test the recovery time of their networks Provides up to 1ms accuracy on Ethernet Switching
Gives detailed reports of network outages Discovers and probes the responsiveness of multiple very quick and effective network analysis tool A Configurable Parameters Include Device detection parameters Device response parameters Contact Name sweep time Ping Time out period sweep retries Ping Intervals Ping
devices simultaneously equipment response times

RuggedDirector is RuggedComs serial port redirection application designed to extend the life and reach of applications written for serial communications. With RuggedDirector, serial port communications are no longer limited by serial protocol cable length requirements or physical port counts that restrict the design and flexibility of networks and the ability to manage them. Using RuggedDirector, the application communications destined for host serial ports are mapped to the host LAN ports for transport across a TCP/IP network to RuggedCom serial servers. This allows the host to be located centrally for easier management and maintenance and provides access to many more serial devices. The redirection is done seamlessly and with no modification required to the host application providing extended life to both the application and the serial devices that it communicates with. RuggedDirector saves time and cost allowing legacy serial devices and applications to communicate over LAN connections without modification to hardware or software. RuggedDirector is a complimentary software package designed to work with RuggedCom serial device servers.

Features and Benefits: Redirect serial port traffic over the network extending the life and
Eliminate physical port restriction with up to 128 virtual serial ports Intuitive Windows based GUI to get up and running quickly Monitor real-time status and log traffic for quick problem resolution Load and save configuration profiles for backup and migration Re-use existing applications without modifications
range of serial devices

www.RuggedCom.com

11

RUGGED Solutions

Managed, Secure Remote Access Solutions CrossBow is a proven Secure Access Management solution designed to provide NERC CIP compliant access to Intelligent Electronic Devices. The CrossBow Station Access Controller complements the product family by providing a solution at the substation for managing local IED access, while maintaining stringent security methodologies in line with NERC CIP compliance and industry best practices. This allows the CrossBow product to further enhance productivity gains for administrators and users while achieving full NERC compliance in managing, securing and reporting on remote access. When used in combination, the CrossBow Secure Access Manager and Station Access Controller form an integrated, comprehensive solution with a seamless configuration environment. CrossBow Station Access Controller The CrossBow Station Access Controller complements the product family by providing a solution at the substation for managing local IED access, while maintaining stringent security methodologies in line with NERC CIP compliance and industry best practices. This allows the CrossBow product to further enhance productivity gains for administrators and users while achieving full NERC compliance in managing, securing and reporting on remote access. System Architecture CrossBow allows an IED maintenance application to remotely communicate with its associated IEDs, as if the user were directly connected to the IED with a serial cable or network connection. The Station Access Controller expands the solution by positioning a hardened controller directly in the substation for managing users who are physically present in the substation. Users can now log into the CrossBow central authority from within the substation, maintaining consistent security administration in adherence with NERC CIP. Alternately, the Station Access Controller provides for a secure, Emergency Mode, where the network connection to the enterprise has been lost. In this mode, security is still maintained in adherence with NERC CIP, while providing the local user full functionality, and complete logging of activity.

Features and Benefits: Complete solution for both local, substation access and
Automatic configuration for all Station Access Controllers through Simple, user-friendly GUI, granting transparent access to IEDs Preserves investment in legacy gateway devices and Strong (2-factor) authentication using existing methodologies (e.g. RSA SecurID) Meets NERC standards for cybersecurity Individual user accounts Audit logs
communication infrastructure from virtually any software application the central Access Manager enterprise-wide administration

CrossBow Secure Access Manager

Active Directory Control

RSA Authentication Server

Modems

Network

CrossBow Station Access Controller

Gateway

Modem/ Port Switch

Relay

Relay

RTU

Electronic Security Perimeter

12

RUGGED Solutions

eLAN Modular Linux-based Servers The modularity and flexibility of our eLAN architecture allows RuggedCom to easily deliver systems containing the exact functionality for a specific requirement. Users can select any of the wide range of eLAN applications, including 40+ protocols. If required, our development staff can be contracted to develop custom functionality. Substation Communications Server The eLAN SCS typically resides in the substation and has a direct connection to all IEDs. It provides a single point of access to these devices, over a Wide Area Network (WAN) or modem connection. The strength of the eLAN SCS lies in its ability to support multiple, concurrent host interfaces; each getting the specific data it needs. For example, from a particular relay, SCADA data may be sent to the EMS, using a SCADA protocol; a different subset of data may go to a historian, such as PI or eDNA, using OPC, and fault files may be automatically extracted and distributed to interested users. eLANUniversal DNP Gateway The eLAN UDG is based on the robust, flexible Linux architecture, and is available on a variety of diskless hardware platforms, and I/O configurations. The eLAN Configurator allows rapid configuration and deployment of UDG systems. The eLAN Universal DNP Gateway Application Guide provides additional details on applying the UDG in different real-world configurations. The eLAN Universal DNP Gateway (UDG) is an off-theshelf solution to a wide range of applications in systems using DNP 3.0, including:
Data concentrator Serial to Ethernet (TCP/IP or UDP/IP) conversion Device proxy server Front end processor / sub master acceleration Poll Multi-master support DNP Router Encryption, using SSL Authentication, using PKI

eLAN Front End Processor The eLAN Front-End Processor (FEP) is based on the field-proven TIE (Telemetry Integration Environment) module, which was originally developed as the telemetry front end for a major EMS vendor and is currently installed in over 50 utilities worldwide. The eLAN FEP provides protocol mediation capability in a vendor-neutral configuration, allowing users of a wide range of EMS systems to offload many of the tasks of managing communications with their field devices. eLAN FEPs are frequently deployed to provide capabilities not available in native front ends, such as IP network support, security, or simply as a cost effective way to add additional ports. The eLAN FEP may be easily upgraded to provide full enterprise application integration through the addition of open interfaces such as OLE for Process Control (OPC) and ODBC. These interfaces allow other applications, such as historians or enterprise databases, to access data from field devices without requiring an interface directly to the EMS.
EMS / SCADA Reflex HMI

Relay Engineering Access


WAN

RTU DFR eLAN Substation Communication Server Historian Meter

www.RuggedCom.com

13

RUGGED Solutions

Monitoring and Control for Distribution Systems RuggedComs Reflex is a monitoring and control application purpose built for distribution networks, allowing the creation of systems that cover the spectrum from single user HMI to mobile distribution management to enterprise level SCADA. Utilities now have a cost-effective visualization facility to monitor, remotely control and report on their networks. Rapid Development Reflexs web and database-centric architecture allows for ultimate flexibility in getting projects developed quickly and cost effectively. Electric utility specific templates and graphic elements allow for rapid design and deployment. Many device types such as the 5800 Series of controls and IntelliRupters from S&C, along with SEL relays and Schneider power quality meters are supported out-of-the-box and are quickly configurable. Cost Effective Client Access With a web-launched Client architecture customers dont have to choose only a select few to have the system on their computer. Any desktop, laptop or tablet capable of running Java or a web browser can have access to information. Mobility Reflexs web-launched architecture also makes it easier than ever to support field personnel who need to securely monitor and control devices. No client software installation is required, just connect to the Reflex server like any other user. IT Friendly Reflex is based entirely on modern, cross-platform technology, such as web (HTTP+SSL), SQL databases, and Java. This insures that your investment is not boxed in to a specific database or operating system. Ease of Use The Reflex client is a simple point and click interface, allowing desktop or mobile users to quickly access devices and information summaries. For administrators, the Reflex Designer has a drag-and-drop designer interface with templates of pre-built, utility specific graphics. Changes made in Designer are immediately reflected in all Client views.

Scalability Reflex is based on modern software architecture and systems: Java, web servers, databases and protocols. Combined with advanced features like load-balancing clustering and client re-targeting, its scalability is exceptional. Data throughput on RuggedComs eLAN Front End Processors is proven at several utilities, handling systems that scale to many hundred thousand data points. From a single user HMI application to enterprise-wide SCADA that spans service territories via corporate WANs to the base for a future Distribution Management System, Reflex is designed to expand to virtually any customers requirements. Security The Reflex was built with security in mind from the ground up. Communication channels are encrypted using SSL technology. SCADA projects use advanced role-based authentication, and can integrate seamlessly with corporate network security using Microsoft Active Directory.t. Features and Benefits: Complete solution for both local, substation access and
Automatic configuration for all Station Access Controllers through Simple, user-friendly GUI, granting transparent access to IEDs Preserves investment in legacy gateway devices and Strong (2-factor) authentication using existing methodologies (e.g. RSA SecurID) Meets NERC standards for cybersecurity Individual user accounts Audit logs
Switch Control

enterprise-wide administration the central Access Manager

from virtually any software application communication infrastructure

Power Meter

Automation Network

Relay

Visualization, Logic & Reporting

Reflex Server

Database

Connect to any number of databases

Web-Launched Clients

Access projects anywhere with an unlimited number of clients

Web-Launched Designers
Design projects concurrently with multiple designers

14

RUGGED Solutions

OpenHouse
RuggedComs OpenHouse is an enterprise asset management application, specifically designed to address the historical data needs of the operations, engineering, maintenance and planning departments of an electric utility. OpenHouse represents the next logical step in addressing the complete needs of a utility seeking to archive and present field information to many users with varying requirements. This enterprise-wide information resource streamlines what is now an intricate mixture of interfaces and legacy applications that are difficult to enhance and expensive to maintain. Long term storage, analysis, and presentation of substation and feeder information is the primary goal of the OpenHouse solution. Combined with RuggedComs eLAN automation solutions and professional services, the system provides an easy to deploy, robust platform for data archiving and decision support. Based on the proven PI System, from OSIsoft , and SQL Server relational database from Microsoft, OpenHouse provides a cost effective solution to address current needs as well as a scaleable architecture to meet future requirements. In bringing together RuggedComs product and service expertise in substation integration and automation with OSIsofts performance management capabilities we are focused on improving returns and addressing requirements in the areas of:
Asset management Condition based maintenance SCADA historian Virtual SCADA system
Enterprise
Planning Maintenance Engineering

OpenHouse

WAN

Station

Reflex HMI

eLAN Substation Communication Server

Relays

DFR

DFRs

RTUs

Meters

Features and Benefits: Simple, integrated view of major assets Event-driven, real time information Real time notification of changing conditions Rich graphical presentation through thin-client Collect data from multiple sources and databases Integration with Enterprise systems from SAP and Microsoft

www.RuggedCom.com

15

RuggedMC Ethernet Media Converters

Features
Order Code

RuggedMC RMC
RMC - __ - __ PS-CT

RuggedMC RMC20
RMC20 - ___ PS

RuggedMC RMC40
RMC40 - __ - ____ PS - P3P4

RuggedMC RMC41
RMC41 - __ - ____ PS - P2

Port Options
Number of Ports 1 10BaseT-to-10Base FL, 1 100BaseTX-to-100BaseFX RJ45 10FL ST, 100FX MTRJ, 100FX LC Protocol Independent: 1 RS485, RS422 or RS232, RS232 to RS485/422 N/A ST Option: 2 10/100TX +1- 100FX Port, 2 10/100 TX Ports + 2 100 FX Port, 4 10/100 TX Port. RJ45 100FX ST/SC/MTRJ, 100FX SC/LC Option: 2 10/100TX +1- 100FX Port, 2 10/100 TX Ports + 2 100 FX Port, 4 10/100 TX Port. RJ45 100FX ST/SC/MTRJ, 100FX SC/LC

RJ Connector Fiber Optic Connectivity

Fiber Mode
Multimode Singlemode 2km 15km N/A 5km 2km Up to 90km 2km Up to 90km

Power Supply
Power Range Power Consumption 24VDC: 18-36 VDC, 48VDC: 36-59 VDC, AC/DC: 88-300VDC & 85-264VAC 5W(Max) 2W(Max) 5W(Max) 5W(Max)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 2.3 x 4.3 x 3.7 DIN rail or Panel Mounted 0.68kg IP40 (1mm) 21 AWG galvanized steel enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

2-Ethernet Ports with Optional Dual Fiber Optics T1 10/100TX port + 1 100FX port (SC/ST) Long haul optics allow distances from 20km to 90km TFLMM = 10BaseT to 10FL MM, 850nm, 2km, ST TFLSM = 10BaseT to 10FL SM, 1310nm, 15km, SFF ST TXFXMM = 100BaseTX to 100FX MM, 1300nm, 2km, SFF MTRJ TXFXSM = 100BaseTX to 100FX SM, 1310nm, 15km, SFF LC

RMC 41:

CT: Conversion Type (RMC)

RMC 41:

00 = None TX = 1 x 10/100BaseTX (1) MJ = 1 X 100BaseFX - MM 1300nm, MTRJ MC = 1 x 100BaseFX -MM 1300nm, SC MT = 1 x 100BaseFX - MM 1300nm, ST L2 = 1 x 100BaseFX - SM 1310nm, LC, 20km L5 = 1 x 100BaseFX - SM 1310nm, LC, 50km L9 = 1 x 100BaseFX - SM 1310nm, LC, 90km C2 = 1 x 100BaseFX - SM 1310nm, SC, 20km (2) C5 = 1 x 100BaseFX - SM 1310nm, SC, 50km (2) C9 = 1 x 100BaseFX - SM 1310nm, SC, 90km (2)

DIN rail mounting is standard For Panel mounting, order P/N 41-12-006

Mounting Options

16

RuggedSwitch i800, i801, i802, i803

Features
Encryption

RuggedSwitch i800/i800NC
128-bit/56-bit Encryption

RuggedSwitch i801/i801NC

RuggedSwitch i802/i802NC

RuggedSwitch i803/i803NC

Port Options
Number of Ports 8-10/100Tx 8-10/100Tx + 1-1000LX or 1-10/100/1000Tx 6-10/100Tx + 1-100FX or 2-100FX or 2-1000LX or 2-10/100/1000Tx 4-10/100Tx + 1-100FX + (2-1000LX or 2-100FX)

Port Types Fiber Optic Connectivity

RJ45, Fiber ports, Copper ports, Serial ports LC

Fiber Mode
Multimode Singlemode Up to 2km Up to 20km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches.

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 0.4A 9W(Max) 1A@30VDC

Switch Properties
ROS Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, SNTP,Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad),

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 4.5 x 2 x 3.5 DIN Rail 1kg IP40 (1mm) Cast Aluminum Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-4kV(Enclosure Contact), +/-8kV(Enclosure Air) 10 V/m Single Ports +/-2kV, D.C. Power Ports +/-1kV @ 2.5kHz Signal Ports +/- 1kV line-to-earth, D.C Power ports +/- 0.5kV line-to-earth/line. 10V@0.5-80 MHz IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

www.RuggedCom.com

17

RuggedSwitch Managed Ethernet Switches


i803 - ____ - ___ - _____ M T MOD i801 - ____ - ___ - ___ - _____ M T P9 MOD M: Management Option = Managed with ROS M = Unmanaged U T: Temperature Option = -20 to +60C T = -40 to +85C U P9: i 801 Port 9 Options 1CG01 = 10/100/1000Base TX 1FG01 = 1000SX Multilmode LC 850nm 500m 1FG03 = 1000LX Singlemode LC 1310nm 10km P78: i 802 Port 7&8 Options 1FX11 = 1x 100FX Multimode LC 1310nm, 2km 1FX06 = 1x 100FX Singlemode LC 1310nm, 20km FX11 = 2x 100FX Multimode LC 1310nm, 2km i802 - ____ - ___ - ____ - _____ M T P7P8 MOD i803 - ____ - ___- ___- ____ - _____ M T P5 P6P7 MOD
FX06 = 2x 100FX Singlemode LC 1310nm, 20km FG01 = 2x 1000SX Multilmode LC 850nm 500m FG03 = 2x 1000LX Singlemode LC 1310nm 10km CG01 = 2x 10/100/1000TX

P5: i 803 Port 5 100FX Fiber Optic Options 1FX11 = 1x 100FX Multimode LC 1310nm, 2km 1FX06 = 1x 100FX Singlemode LC 1310nm, 20km P6P7: i 803 Port 6&7 Fiber Optic Options FX11 = 2x 100FX Multimode LC 1310nm, 2km FX06 = 2x 100FX Singlemode LC 1310nm, 20km FG01 = 2x 1000SX Multilmode LC 850nm 500m FG03 = 2x 1000LX Singlemode LC 1310nm 10km
= None XX = Conformal Coating C01

MOD: Manufacturing Modifications

RS900 - ____ - ___- ___- ____ - ____ - _____ PS M P7 P8 P9 MOD


RS900: 6-10/100Base TX

RS940G - ____ - ___- _______ - _____ PS M P7P8 MOD


RS940G: 6-10/100/1000Base TX

RS900G - ____ - ___- _______ - _____ PS M P9P10 MOD


RS900G: 8-10/100Base TX

PS: Power Supply = 24 VDC (10-36 VDC) 24 = 48 VDC (36-72 VDC) 48 = 85-264VAC or 88-300VDC, 0.1A HI M: Mounting Option = DIN Rail D = Panel Mount P = None N P7, P8, P9: Port 7-9 Options* = No port 00 = 10/100TX (if selected, port 7&8 must both be TX) TX 100FX 1x = 1 x 100FX - Multimode 1300nm, MTRJ connector MJ = 1 x 100FX - Multimode 1300nm, SC connector MC = 1 x 100FX - Multimode 1300nm, ST connector MT = 1 x 100FX - Multimode 1300nm, LC connector ML = 1 x 100FX - Singlemode 1310nm, ST connector, Standard 20km T2 = 1 x 100FX - Singlemode 1310nm, LC connector, Standard 20km L2 = 1 x 100FX - Singlemode 1310nm, LC connector, Intermediate L5
= 1 x 100FX - Singlemode 1310nm, LC connector, Long Reach 90km L9 = 1 x 100FX - Singlemode 1310nm, SC connector, Standard 20km C2 = 1 x 100FX - Singlemode 1310nm, SC connector, Intermediate C5
Reach 50km = 1 x 100FX - Singlemode 1310nm, SC connector, Long Reach 90km C9 Reach 50km

P7P8: Transceiver Options XXXX = None = Dual 10/100/1000TX RJ45 2TX 2SFP = Dual 1000X SFP (Mini-GBIC). Order SFP Optics Separately 2LCMM = Dual 1000SX Multimode LC 850nm 500m 2LC10 = Dual 1000LX Singlemode LC 1310nm 10km 2LC25 = Dual 1000LX Singlemode LC 1310nm 25km 2SC10 = Dual 1000LX Singlemode SC 1310nm 10km 2SC25 = Dual 1000LX Singlemode SC 1310nm 25km P9P10 Transceiver Options(2) 2SFP = Dual 1000X SFP (Mini-GBIC). Order SFP Optics Separately 2LCMM = Dual 1000SX Multimode LC 850nm 500m 2LC10 = Dual 1000LX Singlemode LC 1310nm 10km 2LC25 = Dual 1000LX Singlemode LC 1310nm 25km 2SC10 = Dual 1000LX Singlemode SC 1310nm 10km 2SC25 = Dual 1000LX Singlemode SC 1310nm 25km SFP (Mini-GBIC) Transceiver Options(1)(2) 25-10-0111 = 1000SX SFP, Multimode, LC, 850nm, 500m (1)(3) 25-10-0100 = 1000LX SFP, Singlemode, LC, 1310nm, 10 km (1) 25-10-0101 = 1000LX SFP, Singlemode, LC, 1310nm, 25 km (1) 25-10-0109 = 1000LX SFP, Singlemode, LC, 1550nm, 70 km (1)(3)
= None XX = Conformal Coating C01

MOD: Manufacturing Modifications

Notes * If P7 and P8 are selected, they must have the same connector type. 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 Should you not find an appropriate fiber optic option listed here, please consult RuggedCom for other options. 3 These tranceivers have an operating temperature range of -20 to +85C. All other tranceivers have an operating temperature range of -40 to +85C.

18

RuggedSwitch RS900, RS900G, RS940G

Features
Encryption

RuggedSwitch RS900/RS900NC
128-bit/56-bit Encryption

RuggedSwitch RS900G/RS900GNC

RuggedSwitch RS940G/RS940GNC

Port Options
Number of Ports 6-10/100BaseTX ports, option for 3 additional Fiber or Copper port RJ45, Fiber Ports, Copper Ports Multimode: ST/SC/LC/MTRJ, Single mode: ST/SC/LC Multimode : LC, LC-SFP, Single mode: SC, LC, LC-SFP 2-Fiber Optical Gigabit Ethernet Ports, 8-Fast EthernetPorts(10/100BaseTX) 6-10/100/1000BaseTX Triple Speed, Optional 2-Gigabit fiber 1000LX, Optional 2 - 10/100/1000BaseTX

Port Type Fiber Optic Connectivity

Fiber Mode
Multimode Singlemode Up to 2km Diff Range: 20/50/90km Up to 500m Diff Range: 10/25/70km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption 24VDC: 10-36 VDC, 48VDC: 36-72 VDC, AC/DC: 88-300VDC & 85-264VAC 10W Max 10W Max 18W Max

Switch Properties
ROS Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON, TACACS+ (encrypted) SSH/SSL (128 bit encryption), MAC based port security, (802.1x), RADIUS Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 2.6" x 7.4" x 5.0" DIN rail or Panel Mounted 1.2kg IP40 (1mm) 20 AWG galvanized steel enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

www.RuggedCom.com

19

RuggedSwitch RS1600, RS1600F, RS1600T

Features
Encryption

RS1600 / RS1600NC
128-bit/56-bit Encryption

RS1600F / 1600FNC

RS1600T / RS1600TNC

16 Port Managed Fiber Optical Ethernet Switches Port Options


Number of Ports Port Type Fiber Optic Connectivity 12-10BaseFL + 2-100BaseFX(Opt: 2-10/100BaseTX) RJ45, Fiber Ports, Copper Ports 10FL ST, 100FX MTRJ, 100FX LC 16-100BaseFX 14-10/100BaseTX + 2-100BaseFX

Fiber Mode
Multimode Singlemode Up to 2km (ST & MTRJ) Up to 15km (LC)

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-59 VDC, AC/DC: 88-300VDC & 85-264VAC 30W 1A@30VDC 34W 21W

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 17.25" x 1.74" x 10.26" 19 Rack Mount, DIN rail or Panel Mounted 2.3 ~ 3.6kg IP40 (1mm) 18 AWG galvanized steel enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

20

RuggedSwitch RS8000, RS8000T, RS8000H, RS8000A

Features
Encryption

RS8000/RS8000NC
128-bit/56-bit Encryption

RS8000T/RS8000TNC

RS8000H/RS8000HNC

RS8000A/RS8000ANC

8 Port Managed Fiber Optical Ethernet Switch Port Options


Number of Ports Port Types Fiber Optic Connectivity 8-100BaseFx RJ45, Fiber ports, Copper ports 10FL ST, 100FX ST/SC/MTRJ, 100FX ST/SC/LC 6-10/100BaseTx + 2-100BaseFX(MTRJ/LC) 4-10/100BaseTx + 4-100BaseFX(SC/ST) 2-10/100BaseTx + 2-10BaseFL + 4-100BaseFX

Fiber Mode
Multimode Singlemode Up to 2km Diff Range: 20/50/90km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery 1 of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-59 VDC, AC/DC: 88-300VDC & 85-264VAC 20W 1A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, SNTP,Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 9.8 x 2.43 x 7.81 DIN Rail or Panel Mount 2.25kg IP40 (1mm) 18AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m Single Ports +/-4kV, A.C./D.C. Power Ports +/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

www.RuggedCom.com

21

RuggedSwitch RS1600, RS8000

RS1600 - ____ - ____- ___- ___ - ___ - _____ PS1 PS2 FO MS RJ MOD RS1600F - ____ - ____- _____- ____ - ____ - _____ PS1 PS2 MMX SMX MS MOD

RS1600T - ____ - ____- ___- ____ - _____ PS1 PS2 FO MS MOD

PS1 (Power Supply 1 Rating) = 24VDC (10-36 VDC) 24 = 48VDC (36-59 VDC) 48 = (88VDC-300VDC / 85VAC-264VAC) HI PS2 (Redundant Power Supply 2 Rating) = NONE (No redundant power supply) 0 = 24VDC (10-36 VDC) 24 = 48VDC (36-59 VDC) 48 = (88VDC-300VDC / 85VAC-264VAC) HI MMx (# Multimode 100BaseFX Fiber Ports) MMx = 1310nm, MM, 2km via SFF MTRJ connectors
(x = 0, 4, 8, 12, 16 )*

RJ (RJ45 Uplink Ports Option) Blank = No RJ45 Uplink Ports = RJ45 Uplink Ports option RJ Valid Order Code Examples RS1600-24-0-MM-UM RS1600-HI-48-SM-MS-RJ RS1600F-24-0-MM16-SM0-UM RS1600F-HI-48-MM8-SM8-MS RS1600F-HI-0-MM0-SM16-MS RS1600T-24-0-MM-UM RS1600T-HI-48-SM-MS RS1600T-HI-HI-0-UM 1600T FO (Fiber Options for 100BaseFX Ports) = 1310nm, MM, 2km via SFF MTRJ connectors MM = 1310nm, SM, 15km via SFF LC connectors SM = No Fiber Ports 0
XX = None C01 = Conformal Coating
*Total MM and SM ports must equal 16 *MM= Multimode *SM= SingleModermal Coating

SMx (# Singlemode 100BaseFX Fiber Ports) SMx = 1310nm, SM, 15km via SFF LC connectors
(x = 0, 4, 8, 12, 16 )*

1600 FO (Fiber Options for 100BaseFX Ports) = 1310nm, MM, 2km via SFF MTRJ connectors MM = 1310nm, SM, 15km via SFF LC connectors SM MS (Managed Switch Functions) = Unmanaged UM = Managed Switch option MS

MOD: Manufacturing Modifications

RS8000 - ____ - ___- ___ - _____ PS FO MS MOD RS8000A - ____ - ___- ___ - _____ PS FO MS MOD PS (Power Supply) = 24VDC (10-36 VDC) 24 = 48VDC (36-59 VDC) 48 = (88VDC-300VDC / 85VAC-264VAC) HI RS8000-FO (Fiber Options) = 1300nm, MM, 2km via SFF MTRJ connectors MM SM-X = 1310nm, SM, 15km via SFF LC connectors 4 or 8 SM Fiber Ports) (X= RS8000A-FO (Fiber Options for 100BaseFX Ports Only) = 1300nm, MM, 2km via SFF MTRJ connectors MM = 1310nm, SM, 15km via SFF LC connectors SM RS8000H-FO (Fiber Options) MMSC = 1300nm, MM, 2km via SC connectors MMST = 1300nm, MM, 2km via ST connectors SMSC = 1310nm, SM, 20km via SC connectors SMST = 1310nm, SM, 20km via ST connectors

RS8000H - ____ - ___ - _____ PS FO MOD RS8000T - ____ - ___ - _____ PS FO MOD RS8000T-FO (Fiber Options) = 1300nm, MM, 2km via SFF MTRJ connectors MM = 1310nm, SM, 15km via SFF LC connectors SM = No Fiber Ports 0 MS (Managed Switch Functions) = Unmanaged UM = Managed Switch option MS
= None XX = Conformal Coating* C01
*MM= Multimode *SM= SingleModermal Coating

MOD: Manufaturing Modifications

22

IP66/67 RuggedSwitch RS969, M969

Features

IP66/IP67 Rated 10 Port Managed Ethernet Switch with Gigabit Uplink Ports 128-bit/56-bit Encryption

RuggedSwitch RS969 / RS969NC

RuggedSwitch M969 / M969NC

MIL-STD and IP66/IP67 Rated 10 Port Managed Ethernet Switch with Fiber Uplink Ports

Encryption

Port Options
Number of Ports Connectors Fiber Connector 8 Fast Ethernet Ports (10/100BaseTX), 2 Fiber Optical Ethernet Ports (100BaseX and 1000BaseX) IP66/IP67 Rated M12 D-code connectors & IP66/IP67 Rated shrouded RJ45 style connectors IP66/IP67 LC

Fiber Mode
Multimode Singlemode Up to 500m Up to 25km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-59 VDC, AC/DC: 88-300VDC & 85-264VAC 10W 1A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 7.0 x 8.25 x 3.4/3.75 DIN rail or Panel Mounted 2.5kg IP66/IP67 Cast Aluminum

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 Traffic Control Equipment (pending) Hazardous Locations: Class 1, Div 2 MIL-STD 901D - Shock (Hard Mounted) MIL-STD 167 - Vibration MIL-STD 461 - EMI MIL-STD 1399 - Magnetic Field MIL-STD 810 - Temperature and Humidity

www.RuggedCom.com

23

Military Standard Ethernet Switches

Features
Encryption

19 Port Modular Managed Ethernet Switch with Gigabit Uplink Ports 128-bit/56-bit Encryption

MIL-STD RuggedSwitch M2100/M2100NC

MIL-STD RuggedSwitch M2200/M2200NC


9 Port Managed Gigabit Ethernet Switch

Port Options
Number of Ports Port Type Fiber Connectors Up to 3 Gigabit Ethernet ports, up to 16 Fast Ethernet ports (Copper and/or Fiber) RJ45, Fiber Ports, Copper Ports 10FL ST, 100FX ST/LC, 100FX ST/LC, 1000SX LC, 1000LX LC 1000SX LC, 1000LX LC Up to 9 Gigabit Ethernet ports (Copper and/or Fiber)

Fiber Mode
Multimode Singlemode Up to 500m Diff Range:20/50/90km Diff Range:10/25km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 1.2A 48VDC: 36-59 VDC, 0.6A AC/DC: 88-300VDC & 85-264VAC 28W Max Voltage: 250VAC, 125VDC, Max Current: 2A@250VAC, 2A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 18.3 x 1.74 x 12.4 Panel Mount 5.2kg IP40 (1mm) 18 AWG Galvanized Steel Enclosure 4.8kg

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 Traffic Control Equipment (pending) Hazardous Locations: Class 1, Div 2 MIL-STD 901D - Shock (Hard Mounted) MIL-STD 167 - Vibration MIL-STD 461 - EMI MIL-STD 1399 - Magnetic Field MIL-STD 810 - Temperature and Humidity

24

RuggedSwitch M2100, M2200, M969, RS969

M2100 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10

M2100

M2200 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ Main Mount PS1 PS2 S1 S2 S3 S4 S5
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6

M2200

Main: Ethernet and Power Connectors = Ethernet on rear; LED panel on top; power connector on rear B = Ethernet on front; LED panel on top; power connector on rear T = Ethernet on rear; LED panel on front; power connector on rear R = Ethernet on front; LED panel on front; power connector on rear F Mount: Mounting Options = Panel Mount Kit DP = 19 Rack Mount Kit 2 RM = No Mounting Option 00 PS1 and PS2: Power Supply 1 and 2 = 24VDC (10-36VDC), screw terminal block 24 = 48VDC (36-59VDC), screw terminal block 48 = 88-300VDC or 85-264VAC, screw terminal block HI = No Power Supply (PS2 Only) XX M2100 S1, S2, S3, S4, S7, S8, S9 and S10: Ethernet Modules for Slots 1, 2, 3, 4, 7, 8, 9 and 10 XXXX = Empty TX02 = 2 x 10/100Tx Micro-D FL01 = 2 x 10FL - Multimode, 850nm, ST FX01 = 2 x 100FX - Multimode, 1310nm, ST FX11 = 2 x 100FX Multimode, 1310nm, LC FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km

M2100 S5: Gigabit Ethernet Modules for slot 5 M2200 S1, S2, S3, S4: Gigabit Ethernet Modules for Slots 1, 2, 3 & 4 XXXX = Empty CG02 = 2 x 10/100/1000Tx Micro-D FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km M2100 S6: Gigabit Ethernet Modules for slot 6 M2200 S5: Gigabit Ethernet Modules for slot 5 XXXX = Empty X CG02 = 1 x 10/100/1000Tx Micro-D 1 FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m 1 FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km 1 FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km 1
Notes: 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 The unit is not rated for vibration and shock, MIL-STD-901D, while configured with the rack mount kit.

RS969 - _______ - ____ - ____ - ____ - ____ - _____ MODEL PS1 PS2 P9 P10 MOD MODEL: Ethernet and Power Connectors = 8 M12 D-Code Ethernet ports and Mini-Change power Mini M23 = 8 M12 D-Code Ethernet ports and M23 power RJ45 = 8 RJ45 IP67 Ethernet ports and M23 power PS1: Power Supply 1 = 24VDC (10 - 36VDC) 24 = 48VDC (36 - 59VDC) 48 = 88-300VDC or 85-264VAC HI PS2: Power Supply 2 (requires M23 Connector) = None 0 = 24VDC (9 - 36VDC) 24 = 48TH (36 - 59VDC) 48 = 88-300VDC or 85-264VAC HI

M969 - _______ - ____ - ____ - ____ - ____ MODEL PS1 PS2 P9 P10 P9/P10: Port 9 & 10 IP67 Rated Fiber Optical Ports* XXXXX = None 1FG01 = 1000SX Multimode, LC, 850, 500m 1FG03 = 1000LX Singlemode, LC, 1310nm, 10km 1FG05 = 1000LX Singlemode, LC, 1310nm, 25km 1FX11 = 100FX Multimode, 1300nm, LC 1FX06 = 100FX Singlemode, 1300 nm, LC connectors, 20km 1FX08 = 100FX Singlemode, 1300 nm, LC connectors, 50km 1FX10 = 100FX Singlemode, 1300 nm, LC connectors, 90km
= None XX = Conformal Coating C01

MOD: Manufacturing Modifications

*Note: if 2 ports are selected, they must be the same option.

www.RuggedCom.com

25

RuggedSwitch Managed Ethernet Switches

Features
Encryption

RuggedSwitch RSG2100/RSG2100NC
128-bit/56-bit Encryption

19 Port Modular Managed Ethernet Switch with Gigabit Uplink Ports

RuggedSwitch RSG2100P/RSG2100PNC

19 Port Managed Ethernet Switch with Integrated Power over Ethernet

Port Options
Number of Ports Up to 16 Fast Ethernet ports (Copper and/or Fiber) Up to 3 Gigabit Ethernet ports (Copper and/or Fiber) 2 port modules for tremendous flexibility RJ45, Fiber Ports, Copper Ports 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC, 1000SX LC, 1000LX SC/LC 4-10/100BaseTx 802.3af (PoE) ports, Up to 3 Gigabit Ethernet ports - copper and/or fiber, Up to 12 Fast Ethernet ports - copper and/or fiber, Many fiber and connector options

Port Type Fiber Optic Connectivity

Fiber Mode
Multimode Singlemode Up to 500m 100M to 90km, 500M to 70km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range 24VDC: 10-36 VDC, 1.2A 48VDC: 36-72 VDC, 0.6A Hi Voltage: AC/DC: 88-300VDC or 85-264VAC 28W Max Voltage: 250VAC, 125VDC, Max Current: 2A@250VAC, 2A@30VDC 24VDC: 10-36 VDC, 1.2A 48VDC: 36-59 VDC, 0.6A Hi Voltage: AC/DC: 88-300VDC or 85-264VAC PoE Power Supply: 48VDC: 36-59VDC

Power Consumption Critical Alarm Relay

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 18.3 x 1.74 x 12.4 19 Rack Mount, DIN rail or Panel Mounted 5.2kg IP40 (1mm) 18 AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

26

RuggedSwitch RSG2100, RSG2100P

RSG2100 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 MOD
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10

RSG2100P - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 S7 S8 MOD
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10

Main: Ethernet and Power Connectors = Ethernet on rear; LED panel on front; power connector on rear R = Ethernet on front; LED panel on front; power connector on rear F = Ethernet on rear; LED panel on top; power connector on rear B = Ethernet on front; LED panel on top; power connector on rear T Mount: Mounting Options = 19 Rack Mount Kit RM = DIN and Panel Mount Kit DP = 19 Rack, DIN, and Panel Mount Kit RD = No Mounting Option 00 PS1 and PS2: Power Supply 1 and 2(5) = 24VDC (10-36VDC), screw terminal block 24 = 48VDC (36-72VDC), screw terminal block 48 = 88-300VDC or 85-264VAC, screw terminal block HI = 24VDC (10-36VDC), pluggable terminal block 24P = 48VDC (36-72VDC), pluggable terminal block 48P = 88-300VDC or 85-264VAC, pluggable terminal block HIP = No Power Supply (PS2 Only) XX S1, S2, S3, S4, S7, S8, S9 and S10: Ethernet Modules for Slots 1, 2, 3, 4, 7, 8, 9 and 10 XXXX = Empty TX01 = 2 x 10/100Tx RJ45 FL01 = 2 x 10FL - Multimode, 850nm, ST FX01 = 2 x 100FX - Multimode, 1300nm, ST FX02 = 2 x 100FX - Multimode, 1300nm, SC FX11 = 2 x 100FX Multimode, 1300nm, LC FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FX07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km S5: Gigabit Ethernet Modules for slot 5 XXXX = Empty CG01 = 2 x 10/100/1000Tx RJ45 FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km

FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km FG50 = 2 x 1000LX SFP - Blank (no optical transceiver) FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m (3) FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km (3) FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km (3) FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2)(3) FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver) FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km (4) FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km (4) FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km (2)(4)

S6: Gigabit Ethernet Modules for slot 6 XXXXX = Empty 1CG01 = 1 x 10/100/1000Tx RJ45 1FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m 1FG02 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 10km 1FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km 1FG04 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 25km 1FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km 1FG50 = 1 x 1000SX SFP - Blank (no optical transceiver) 1FG51 = 1 x 1000SX SFP - Multimode, 850nm,LC, 500m (3) 1FG52 = 1 x 1000LX SFP - Singlemode, 1310nm, LC,10km (3) 1FG53 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km (3) 1FG54 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2)(3) 1FG70 = 1 x 1000LX GBIC - Blank (no optical transceiver) 1FG71 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km (4) 1FG72 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km (4) 1FG73 = 1 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km (2)(4)
= None XX = Conformal Coating C01
Notes: 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 These transceivers have an operating temperature range of -20 C to +85C. All other transceivers have an operating temperature range of -40C to +85C 3 SFP plugable optics that consist of a blank cage (FG50 for dual, 1FG50 for single) plus specified fiber optic interface(s) installed 4 GBIC plugable optics that consist of a blank cage (FG70 for dual, 1FG70 for single) plus specified fiber optic interface(s) installed 5 Power Supply 1 and 2 must be either both screw terminal block or both pluggable terminal block

MOD: Manufacturing Modifications

www.RuggedCom.com

27

RuggedSwitch Managed Ethernet Switches

Features

RuggedSwitch RSG2200/ RS2200NC 9 Port Managed Gigabit


Ethernet Switch

RuggedSwitch RSG2288/ RS2288NC Modular Managed Gigabit


Switch with IEEE 1588 v2 and IRIG-B

RuggedSwitch RSG2300/ RS2300NC 32 Port Managed Ethernet


Switch with 4 Modular Gigabit Uplink Ports

Encryption

128-bit/56-bit Encryption

Port Options
Number of Ports Up to 9 Gigabit Ethernet ports (Copper and/or Fiber) Up to 9-100FX Fiber Fast Ethernet ports. RJ45, Fiber Ports, Copper Ports 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC, 1000SX LC, 1000LX SC/LC Up to 9 Gigabit Ethernet ports (Copper and/or Fiber) Up to 9-100FX Fiber Fast Ethernet ports. 24-10/100TX copper ports, Optional: Up to 4-1000LX Gigabit Ethernet ports (Copper and/or Fiber) and Up to 8-100FX Fiber Fast Ethernet ports

Port Type Fiber Optic Connectivity

Fiber Mode
Multimode Singlemode Up to 500m 100M to 90km, 500M to 70km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-72 VDC, AC/DC: 88-300VDC & 85-264VAC 28W 28W 32W

Max Voltage: 250VAC, 125VDC Max Current: 2A@250VAC, 2A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 18.3 x 1.74 x 12.4 19 Rack Mount, DIN rail or Panel Mounted 4.8kg IP40 (1mm) 18 AWG Galvanized Steel Enclosure 4.8kg 5.2kg

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

28

RuggedSwitch RSG2200, RSG2288, RSG2300


RSG2200 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 MOD RSG2288 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 MOD
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6

RSG2300 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 MOD

Main: Ethernet and Power Connectors = Ethernet on rear; LED panel on front; power connector on rear R = Ethernet on front; LED panel on front; power connector on rear F = Ethernet on rear; LED panel on top; power connector on rear B = Ethernet on front; LED panel on top; power connector on rear T Mount: Mounting Options = 19 Rack Mount Kit RM = DIN and Panel Mount Kit DP = 19 Rack, DIN, and Panel Mount Kit RD = No Mounting Option 00 PS1 and PS2: Power Supply 1 and 25 = 24VDC (10-36VDC), screw terminal block 24 = 48VDC (36-72VDC), screw terminal block 48 = 88-300VDC or 85-264VAC, screw terminal block HI = 24VDC (9-36VDC), pluggable terminal block 24P = 48VDC (36-72VDC), pluggable terminal block 48P = 88-300VDC or 85-264VAC, pluggable terminal block HIP = No Power Supply (PS2 Only) XX RSG2200/RSG2288 S1, S2, S3, S4: Gigabit Ethernet Modules for Slots 1, 2, 3, and 4 RSG2300 S3 & S4: 100FX/Gigabit Ethernet Modules for Slots 3 & 4 XXXX = Empty CG01 = 2 x 10/100/1000Tx RJ45 FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km FG50 = 2 x 1000LX SFP - Blank (no optical transceiver) FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2) FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver) FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km (2) FXA01 = 2 x 100FX - Multimode, 1300nm, ST FXA02 = 2 x 100FX - Multimode, 1300nm, SC FXA11 = 2 x 100FX Multimode, 1300nm, LC FXA03 = 2 x 100FX - Multimode, 1300nm, MTRJ FXA04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FXA05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FXA06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FXA07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FXA08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FXA09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FXA10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km RSG2300 S1, and S2: Ethernet Modules for Slots 1 and 2 XXXX = Empty TX01 = 2 x 10/100Tx RJ45 FL01 = 2 x 10FL - Multimode, 850nm, ST FX01 = 2 x 100FX - Multimode, 1300nm, ST FX02 = 2 x 100FX - Multimode, 1300nm, SC

FX11 = 2 x 100FX Multimode, 1300nm, LC FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FX07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km
RS2200/RSG228 S5: Gigabit Ethernet Modules for Slot 5 XXXXX = Empty 1CG01 = 1 x 10/100/1000Tx RJ45 1FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m 1FG02 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 10km 1FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km 1FG04 = 1 x 1000LX - Singlemode, 1310nm, SC connectors, 25km 1FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km 1FG50 = 1 x 1000LX SFP - Blank (no optical transceiver) 1FG51 = 1 x 1000SX SFP - Multimode, 850nm, LC, 500m (3) 1FG52 = 1 x 1000LX SFP - Singlemode, 1310nm, LC,10km (3) 1FG53 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km (3) 1FG54 = 1 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2) (3) 1FG70 = 1 x 1000LX GBIC - Blank (no optical transceiver) 1FG71 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km (4) 1FG72 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km (4) 1FG73 = 1 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km (2)(4) 1FXA01 = 1 x 100FX - Multimode, 1300nm, ST 1FXA02 = 1 x 100FX - Multimode, 1300nm, SC 1FXA11 = 1 x 100FX Multimode, 1300nm, LC 1FXA03 = 1 x 100FX - Multimode, 1300nm, MTRJ 1FXA04 = 1 x 100FX - Singlemode, 1310nm, ST, 20km 1FXA05 = 1 x 100FX - Singlemode, 1310nm, SC, 20km 1FXA06 = 1 x 100FX - Singlemode, 1310nm, LC, 20km 1FXA07 = 1 x 100FX - Singlemode, 1310nm, SC, 50km 1FXA08 = 1 x 100FX - Singlemode, 1310nm, LC, 50km 1FXA09 = 1 x 100FX - Singlemode, 1310nm, SC, 90km 1FXA10 = 1 x 100FX - Singlemode, 1310nm, LC, 90km RSG2288 S6: RSG2288 Modules for Slot 6 XXX = Empty PTP1 = Precision Time Protocol (PTP) Source Card: Inputs - GPS,
IRIG-B, Outputs - IRIG-B AM and TTL

MOD: Manufacturing Modifications = None XX = Conformal Coating C01


Accessories/Options 41-11-0011 - Cable support bracket (one) 43-10-0007 - Power cable (North America three prong connector -> beau) Notes: 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 These transceivers have an operating temperature range of -20 C to +85C. All other transceivers have an operating temperature range of -40C to +85C 3 Base unit comes standard with 24 10/100TX RJ45 ports 4 SFP plugable optics that consist of a blank cage (FG50 for dual, 1FG50 for single) plus specified fiber optic interface(s) installed 5 GBIC plugable optics that consist of a blank cage (FG70 for dual, 1FG70 for single) plus specified fiber optic interface(s) installed 6 Power Supply 1 and 2 must be either both screw terminal block or both pluggable terminal block

www.RuggedCom.com

29

RuggedSwitch Managed Ethernet Switches

Features
Encryption

RuggedSwitch RSG2300P
128-bit Encryption

32 Port Managed Ethernet Switch with Integrated Power over Ethernet

RuggedSwitch RSG2300PNC
56-bit Encryption

32 Port Managed Ethernet Switch with Integrated Power over Ethernet

Port Options
Number of Ports 4-10/100BaseTx 802.3af (PoE) ports, Up to 4 Gigabit Ethernet ports - copper and/or fiber, Up to 24 Fast Ethernet ports - copper and/or fiber,Many fiber and connector options RJ45, Fiber Ports, Copper Ports 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC, 1000SX LC, 1000LX SC/LC 4-10/100BaseTx 802.3af (PoE) ports, Up to 4 Gigabit Ethernet ports - copper and/or fiber, Up to 24 Fast Ethernet ports - copper and/or fiber,Many fiber and connector options

Port Type Fiber Optic Connectivity

Fiber Mode
Multimode Singlemode Up to 500m 100M to 90km, 500M to 70km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 1.2A 48VDC: 36-72 VDC, 0.6A Hi Voltage: AC/DC: 88-300VDC or 85-264VAC PoE Power Supply: 48VDC: 36-59VDC 32W Max Voltage: 250VAC, 125VDC, Max Current: 2A@250VAC, 2A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 18.3 x 1.74 x 12.4 19 Rack Mount, DIN rail or Panel Mounted 5.2kg IP40 (1mm) 18 AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

30

RuggedSwitch RSG2300P, RSG2300PNC

RSG2300P - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 MOD

RSG2300PNC - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 MOD

= Ethernet on rear; LED panel on front; power connector on rear R = Ethernet on front; LED panel on front; power connector on rear F = Ethernet on rear; LED panel on top; power connector on rear B = Ethernet on front; LED panel on top; power connector on rear T

Main: Ethernet and Power Connectors

Mount: Mounting Options = 19 Rack Mount Kit RM = DIN and Panel Mount Kit DP = 19 Rack, DIN, and Panel Mount Kit RD = No Mounting Option 00 PS1: Unit Power Supply = 24VDC (10-36VDC), screw terminal block 24 = 48VDC (36-59VDC), screw terminal block 48 = 88-300VDC or 85-265VAC, screw terminal block HI = 24VDC (10-36VDC), pluggable terminal block 24P = 48VDC (36-59VDC), pluggable terminal block 48P = 88-300VDC or 85-265VAC, pluggable terminal block HIP PS2: PoE Power Supply 48PoE = 48VDC (36-59VDC) PoE Power Supply S1:Ethernet Modules for Slot 1 XXXX = Empty PX01 = 2 additional 10/100 Base Tx PoE ports FL01 = 2 x 10FL - Multimode, 850nm, ST FX01 = 2 x 100FX - Multimode, 1300nm, ST FX02 = 2 x 100FX - Multimode, 1300nm, SC FX11 = 2 x 100FX - Multimode, 1300nm, LC FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ FX04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FX06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FX07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FX08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km The RSG2100P comes standard with 4-10/100BaseTX 802.3af (PoE) compliant Ethernet ports S2: PoE Module for Slot 2 PX01 = 2 x 10/100 BaseTx PoE ports

S3 and S4: 100FX/Gigabit Ethernet Modules for Slots 3 and 4 XXXX = Empty CG01 = 2 x 10/100/1000Tx RJ45 FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km FG03 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 10km FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km FG50 = 2 x 1000LX SFP - Blank (no optical transceiver) FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m (4) FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km (4) FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km (4) FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km (2)(4) FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver) FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km (5) FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km (5) FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km (2)(5) FXA01 = 2 x 100FX - Multimode, 1300nm, ST FXA02 = 2 x 100FX - Multimode, 1300nm, SC FXA11 = 2 x 100FX Multimode, 1300nm, LC FXA03 = 2 x 100FX - Multimode, 1300nm, MTRJ FXA04 = 2 x 100FX - Singlemode, 1310nm, ST, 20km FXA05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km FXA06 = 2 x 100FX - Singlemode, 1310nm, LC, 20km FXA07 = 2 x 100FX - Singlemode, 1310nm, SC, 50km FXA08 = 2 x 100FX - Singlemode, 1310nm, LC, 50km FXA09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km FXA10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km
= None XX = Conformal Coating C01
Notes: 1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices. 2 These transceivers have an operating temperature range of -20 C to +85C. All other transceivers have an operating temperature range of -40C to +85C 3 Base unit comes standard with 24 10/100TX RJ45 ports 4 SFP plugable optics that consist of a blank cage (FG50 for dual, 1FG50 for single) plus specified fiber optic interface(s) installed 5 GBIC plugable optics that consist of a blank cage (FG70 for dual, 1FG70 for single) plus specified fiber optic interface(s) installed

MOD: Manufaturing Modifications

www.RuggedCom.com

31

RuggedVDSL EoVDSL Ethernet Switches

Features
Encryption

RS900L / RS900LNC
128-bit/56-bit Encryption

RS910L / RS910LNC

RS920L / RS920LNC

RS930L / RS930LNC

Port Options
Number of Ports 6 (10/100BaseTX), Add 2 (10/100BaseTX or 100BaseFX), EoVDSL Interface Up to 1 (EoVDSL) interface, Up to 2 Serial and/or 2 Fast Ethernet Ports. Up to 2 (EoVDSL interface) Up to 2 RS485/422/232 Serial Ports(DB9 or RJ45) Up to 6 Fast Ethernet ports (10/100BaseTX) Up to 2 EoVDSL interface

Ethernet over VDSL Serial Connectors Port Types Fiber Optic Connectivity

RJ11, Symmetric data rates up to 35Mbps, Asymmetric data rates up to 40Mbps RS485/RS422/RS232 Serial Ports (DB9 or RJ45) & Serial Fiber Interface (ST) available RJ45, Fiber ports, Copper ports, Serial ports 10FL ST, 100FX ST/SC/MTRJ, 100FX ST/SC/LC

Fiber Mode
Ethernet over VDSL Multimode Singlemode 5km Up to 2km Diff Range: 20/50/90km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery 1 of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-59 VDC, AC/DC: 88-300VDC & 85-264VAC 10W 1A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad) SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 2.6 x 7.4 x 5.0 DIN Rail or Panel Mount 1.2kg IP40 (1mm) 20AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m Single Ports +/-4kV, A.C./D.C. Power Ports +/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

32

RuggedVDSL RS900L, RS910L, RS920L, RS930L

RS900L - ____ - ___- ___- ____ - ____ - _____ PS M P7 P8 VV MOD RS910L - ____ - ___ - ___ - ___ - ____ - _____ PS M S E VV MOD

RS920L - ____ - ___ - ___ - ____ - ____ - _____ PS M S VV1 VV2 MOD RS930L - ____ - ___ - ____ - ____ - _____ PS M VV1 VV2 MOD

PS: Power Supply = 24 VDC (10-36VDC) 24 = 48 VDC (36-72VDC) 48 = 87-264VAC or 88-300VDC HI M: Mounting Option = DIN Rail D = Panel Mount P = None N RS900L P7, P8: Additional Ethernet Ports = None XX = 1 x 10/100BaseTX (if selected, P7 & P8 must both be TX) TX = Multimode 1300nm, MTRJ connector MJ = Multimode 1300nm, SC connector MC = Multimode 1300nm, ST connector MT = Multimode 1300nm, LC connector ML = Singlemode 1310nm, ST connector, Standard 20km T2 = Singlemode 1310nm, LC connector, Standard 20km L2 = Singlemode 1310nm, LC connector, Intermediate Reach 50km L5 = Singlemode 1310nm, LC connector, Long Reach 90km L9 = Singlemode 1310nm, SC connector, Standard 20km C2 = Singlemode 1310nm, SC connector, Intermediate Reach 50km C5 = Singlemode 1310nm, SC connector, Long Reach 90km C9 RS910L E: Additional Ethernet Ports XXXX = No Ethernet Ports TX01 = 2 x 10/100TX RJ45 FL01 = 2 x 10FL - Multimode, 850 nm, ST connectors FX01 = 2 x 100FX - Multimode, 1300 nm, ST connectors FX02 = 2 x 100FX - Multimode, 1300 nm, SC connectors FX03 = 2 x 100FX - Multimode, 1300 nm, MTRJ connectors FX11 = 2 x 100FX - Multi mode, 1300nm, LC connectors FX04 = 2 x 100FX - Singlemode, 1300 nm, ST connectors, 20km FX05 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 20km FX06 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 20km FX07 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 50km FX08 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 50km FX09 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 90km

RS910L/RS920L S: Serial Port Options = None XX = 2 x RS232/422/485 DB9 S1 = 2 x RS232/422/485 RJ45 S2 = 2 x Fiber 850nm ST S3 RS900L/RS910L VV: VDSL Interface = Standard reach (<2.5km) V1 = Long Reach (5km) Master / CO V2 = Long Reach (5km) / CPE V3 RS920L/RS930L VV1, VV2: VDSL Interface = Standard reach (<2.5km) V1 = Long Reach (5km) Master / CO V2 = Long Reach (5km) / CPE V3 Power Cables 43-10-0008 - Bare-wire 43-10-0007 - with lugs
= None XX = Conformal Coating C01

MOD: Manufacturing Modifications

www.RuggedCom.com

33

RuggedAIR Wireless LAN Devices

Features
Encryption

RS900W / RS900WNC
128-bit/56-bit Encryption

RS910W / RS910WNC

RS920W / RS920WNC

RS930W / RS930WNC

Port Options
Number of Ports 6 Fast Ethernet ports (10/100BaseTX) Optional 2 (10/100BaseTX or 100BaseFX) 2 Fast Ethernet ports (10/100BaseTX or 100BaseFX), 2 Serial ports, (Db9 or RJ45) 1 Ethernet over VDSL (EoVDSL) interface 2 RS485/RS422/RS232 Serial Ports (DB9 or RJ45) 1 Ethernet over VDSL (EoVDSL) interface 6 Fast Ethernet Ports (10/100BaseTX)

Port Types Connectors Ethernet over VDSL Fiber Optic Connectivity

RJ45, Fiber ports, Copper ports, Serial Ports. EoVDSL RS485/RS422/RS232,(DB9 or RJ45), ST One EoVDSL port, RJ11 connector, Symmetrical data rates up to 50Mbps Multimode : MRTJ/ST/SC/LC , Singlemode: LC/SC/ST

Fiber Mode
Ethernet over VDSL Multimode Singlemode N/A Up to 2km Diff Range: 20/50/90km N/A Up to 5km Up to 5km

Wireless Specifications
Antenna type Operating channels/ frequencyrange Data rates Modulation Technology Transmit Power Receiver Sensitivity Removable, Upgradable 3dBi Antenna with R-SMA (male) connector 11 channels, 2.400 - 2.4720 GHz (US, Canada) 13 channels, 2.400 - 2.4835 GHz (ETSI) 14 channels, 2.400 - 2.4970 GHz (Japan) IEEE 802.11b: 11/5.5/2/1 Mbps IEEE 802.11g: 54/48/36/24/18/12/9/6 Mbps IEEE 802.11b: DSSS over CCK (11/5 Mbps), DQPSK (2 Mbps), DBPSK (1 Mbps) IEEE 802.11g: OFDM over 64QAM, 16QAM, QPSK, BPSK IEEE 802.11b: 20dBm nominal @ 11 Mbps IEEE 802.11g: 16dBm nominal @ 54 Mbps IEEE 802.11b: -88dBm @ 11 Mbps with 8% FER IEEE 802.11g: -74dBm @ 54 Mbps with 10% FER

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery 1 of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-72 VDC, Universal high-voltage range: 88-300VDC & 85-264VAC 10W Form-c failsafe contact relay: 1A@30VDC

Switch Properties
ROS Features Management Tool Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad) SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

34

Physical
Dimension Mount Weight Ingress Protection Enclosure 2.6 x 7.4 x 5.0 DIN Rail or Panel Mount 1.2kg IP40 (1mm) 20AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m Single Ports +/-4kV, A.C./D.C. Power Ports +/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

RS900W - ____ - ___- ___- ____ - ____ - _____ PS M P7 P8 WW MOD


Base unit includes 802.11i wireless interface and 6 10/100BaseTx Ethernet ports

RS920W - ____ - ___ - ___ - ____ - _____ PS M S VV MOD RS930W - ____ - ___ - ____ - ____ - _____ PS M VV WW MOD
Base Unit includes 802.11 wireless interface and 10/100BaseTx Ethernet ports

RS910W - ____ - ___ - ___ - ___ - ____ - _____ PS M S E WW MOD

PS: Power Supply = 24VDC (10-36VDC) 24 = 48VDC (36-72VDC) 48 = 85-264VAC or 88-300VDC HI M: Mounting Option = DIN Rail D = Panel Mount P = None N RS900W P7, P8: Additional Ethernet Ports = None XX = 1 x 10/100BaseTX (if selected, P7 & P8 must both be TX) TX = 1 x 100BaseFX Multimode, MTRJ connector MJ = 1 x 100BaseFX Multimode, SC connector MC = 1 x 100BaseFX Multimode, ST connector MT = 1 x 100BaseFX Multimode, LC connector ML = 1 x 100BaseFX Singlemode, ST connector, 20km T2 = 1 x 100BaseFX Singlemode, LC connector, 20km L2 = 1 x 100BaseFX Singlemode LC connector, 50km L5 = 1 x 100BaseFX Singlemode LC connector, 90km L9 = 1 x 100BaseFX Singlemode SC connector, 20km C2 = 1 x 100BaseFX Singlemode SC connector, 50km C5 = 1 x 100BaseFX Singlemode SC connector, 90km C9 RS910W/RS920W S: Serial Port Options = None XX = 2 x RS232/422/485 DB9 S1 = 2 x RS232/422/485 RJ45 S2 = 2 x Fiber 850nm ST S3 RS910W E: Ethernet Ports Options XXXX = No Ethernet ports TX01 = 2 x 10/100Tx RJ45

FL01 = 2 x 10FL - Multimode, 850 nm, ST connectors FX01 = 2 x 100FX - Multimode, 1300 nm, ST connectors FX02 = 2 x 100FX - Multimode, 1300 nm, SC connectors FX03 = 2 x 100FX - Multimode, 1300 nm, MTRJ connectors FX11 = 2 x 100FX - Multi mode, 1300nm, LC connectors FX04 = 2 x 100FX - Singlemode, 1300 nm, ST connectors, 20km FX05 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 20km FX06 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 20km FX07 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 50km FX08 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 50km FX09 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 90km FX10 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 90km

RS920W/RS930W VV: VDSL Interface = Standard reach (<2.5km) V1 = Long Reach (5km) Master / CO V2 = long Reach (5km) /CPE V3 WW: Wireless Options = 802.11 - US (North America) W1 = 802.11 - EU (European Union) W2 = 802.11 - CH (China)(Coming soon) W3 = 802.11 - AU (Australia) W4 = 802.11 - IN (India) W6
= None XX = Conformal Coating C01

MOD: Manufaturing Modifications

Power Cables 43-10-0008 - Bare-wire 43-10-0007 - with lugs

www.RuggedCom.com

35

RuggedServer Serial Device Servers

Features
Encryption

RS910/RS910NC
128-bit/56-bit Encryption

RS400/RS400NC

RS401/RS401NC

RMC30

Port Options
Number of Ports Up to 3 fast Ethernet ports (Copper and/ or fiber). Integrated Switch. Integrated Ethernet switchUp to 4 ports Integrated Ethernet switch Up to 4 ports 2-Port Serial-to-Ethernet Converter

Port Type Fiber Optic Connectivity

RJ45, Fiber Port, Copper Port, Serial port 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC

Fiber Mode
Multimode Singlemode Up to 100m 100M to 90km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay 24VDC: 10-36 VDC, 48VDC: 36-59 VDC, High Voltage AC/DC: 88-300VDC & 85-264VAC 10W 8W 8W 2W

Form-C failsafe contact relay: 1A@30VDC

Switch Properties
ROS Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 2.6 x 7.4x 5.0 DIN rail or Panel Mounted 1.2kg IP40 (1mm) 20 AWG Galvanized Steel Enclosure 18 AWG Galvanized Steel Enclosure 21 AWG galvanized steel enclosure 2.2kg 2.2kg 0.68kg 7.96 x 1.74x 11.47 6.76 x 3.5x 7.42 2.3 x 4.3x 3.7

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

36

RuggedServer RS910, RS400, RS401, RMC30

RS910 - ____ - ___- ___- ____ - ____ - _____ PS M S E1 E2 MOD RS400 - ____ - ___ - _____ - ___ - ____ - _____ PS M E1E2 SP MP MOD RS401 - ____ - ___- _____- ____ - ____ - _____ PS M E1E2 SP MP MOD PS: Power Supply = 24 VDC (10-36 VDC) 24 = 48 VDC (36-59 VDC) 48 = 85-264VAC or 88-300VDC HI M: Mounting options = Din Rail D = Panel Mounting P = None N RS910 S: Serial Port Options = None XX = 2 x RS232/422/485 DB9 S1 = 2 x RS232/422/485 RJ45 S2 = 2 x Fiber 850nm ST S3 RS910 E1: Ethernet Ports Options XXXX = No Ethernet ports TX01 = 2 x 10/100TX RJ45 FL01 = 2 x 10FL - Multimode, 850 nm, ST connectors FX01 = 2 x 100FX - Multimode, 1300 nm, ST connectors FX02 = 2 x 100FX - Multimode, 1300 nm, SC connectors FX03 = 2 x 100FX - Multimode, 1300 nm, MTRJ connectors FX11 = 2 x 100FX - Multi mode, 1300nm, LC connectors FX04 = 2 x 100FX - Singlemode, 1300 nm, ST connectors, 20km FX05 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 20km FX06 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 20km FX07 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 50km FX08 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 50km FX09 = 2 x 100FX - Singlemode, 1300 nm, SC connectors, 90km FX10 = 2 x 100FX - Singlemode, 1300 nm, LC connectors, 90km RS910 E2: Ethernet Ports Options = No port XX = 1 x 100BaseTX - RJ45 connector TX = 1 x 100BaseFX - Multimode, MTRJ connector MJ = 1 x 100BaseFX - Multimode, SC connector MC = 1 x 100BaseFX - Multimode, ST connector MT = 1 x 100BaseFX - Multimode, LC connector ML = 1 x 100BaseFX - Singlemode, ST connector, 20km T2 = 1 x 100BaseFX - Singlemode, LC connector, 20km L2 = 1 x 100BaseFX - Singlemode, LC connector, 50km L5 = 1 x 100BaseFX - Singlemode, LC connector, 90km L9 = 1 x 100BaseFX - Singlemode, SC connector, 20km C2 = 1 x 100BaseFX - Singlemode, SC connector, 50km C5 = 1 x 100BaseFX - Singlemode, SC connector, 90km C9 RS400/RS401 E1E2: Additional Ethernet Ports 1 & 2 Options (1) = 10/100BaseTX RJ45 TX = 10FL Multimode ST, 820nm, 2km FL = 100FX Multimode MTRJ MJ = 100FX Multimode SC MC = 100FX Multimode ST MT = 100FX Multimode LC ML = 100FX Singlemode ST, Standard 20km T2 = 100FX Singlemode LC, Standard 20km L2 = 100FX Singlemode LC, Intermediate Reach 50km L5 = 100FX Singlemode LC, Long Reach 90km L9 = 100FX Singlemode SC, Standard 20km C2 = 100FX Singlemode SC, Intermediate Reach 50km C5 = 100FX Singlemode SC, Long Reach 90km C9 RS400/RS401 SP (Serial Port Options) = 4 x RS232 via DB9 2 = 4 x RS485 via 3 POS screw terminals. 4 = 4 x RS232/RS422/RS485 via DB9 3D = 4 x RS232/RS422/RS485 via RJ45 3R RS400/RS401 MP (Modem Port Options) Blank = No Modem = V.90 (56Kbps) Modem M MOD: Manufacturing Modifications = None XX = Conformal Coating C01

www.RuggedCom.com

37

RuggedServer Serial Device Servers

Features
Encryption

RS416/RS416NC
128-bit/56-bit Encryption

RS416P/RS416PNC

Port Options
Number of Ports Serial Ports Port Type Fiber Optic Connectivity Up to 4 Fast Ethernet Ports, 10/100TX RJ 45, 10 FL Multimode, 100 FX Multimode, IEEE 1588 Optional 2 Fast Ethernet Ports, 10/100TX RJ 45, 10 FL Multimode, 100 FX Multimode

Up to 16 Serial Ports, Software Selectable RS232/RS422/RS485, Db9 or RJ 45 connectors RJ45, Fiber Ports, Copper Ports 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC, 1000SX LC, 1000LX SC/LC

Fiber Mode
Multimode Singlemode Up to 100m 100M to 90km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP. Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range 24VDC: 10-36 VDC, 1.2A 48VDC: 36-59 VDC, 0.6A Hi Voltage: AC/DC: 88-300VDC or 85-264VAC (max) 15W 2A@30VDC 24VDC: 10-36 VDC, 1.2A 48VDC: 36-59 VDC, 0.6A Hi Voltage: AC/DC: 88-300VDC or 85-264VAC (max) PoE Power Supply: 48VDC: 36-59VDC

Power Consumption Critical Alarm Relay

Switch Properties
ROS Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SS (128 bit encryption), MAC base port security, (802.1x), Radius Centralized password management, VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 18.3 x 1.74 x 12.4 19 Rack Mount, DIN rail or Panel Mounted 5.2kg IP40 (1mm) 18 AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

38

RuggedServer RS416, RS416P

RS416 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 MOD
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 RS416

RS416P - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 MOD
Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 RS416P

Main: Ethernet and Power Connectors = Ethernet on rear; LED panel on front; power connector on rear R = Ethernet on front; LED panel on front; power connector on rear F = Ethernet on rear; LED panel on top; power connector on rear B = Ethernet on front; LED panel on top; power connector on rear T Mount: Mounting Options = 19 Rack Mount Kit RM = DIN and Panel Mount Kit DP = 19 Rack, DIN, and Panel Mount Kit RD = No Mounting Option 00 RS416 PS1 and PS2: Power Supply 1 and 2 RS416P PS1: Unit Power Supply = 24VDC (10-36VDC), screw terminal block 24 = 48VDC (36-59VDC), screw terminal block 48 = 88-300VDC or 85-264VAC, screw terminal block HI = 24VDC (10-36VDC), pluggable terminal block 24P = 48VDC (36-59VDC), pluggable terminal block 48P = 88-300VDC or 85-264VAC, pluggable terminal block HIP = No Power Supply (PS2 Only) XX RS416P PS2: PoE Power Supply 48PoE = 48VDC (36-59VDC) PoE Power Supply S1, S2, S3, S4: Serial Port Modules for Slots 1, 2, 3, and 4 2 = Empty (S2,S3,S4 Only) XX = 4 x RS232/RS422/RS485 via DB9 3D = 4 x RS232/RS422/RS485 via RJ45 3R = 4 x Fiber Serial Interface (ST Connector) FS = 4 x RS232/RS422/RS485 & IRIG-B via DB9 1 ID = 4 x RS232/RS422/RS485 & IRIG-B via RJ45 1 IR

RS416 S5, S6: Ethernet Modules for Slots 5 and 6 (2) RS416P S5: Ethernet Modules for Slots 5 XXXX = Empty (S6 Only) PX01 = 2 additional 10/100 BaseTx PoE Ports (RS416P) TX01 = 2 x 10/100Tx RJ45 FL01 = 2 x 10FL - Multimode, 850nm, ST FX01 = 2 x 100FX - Multimode, 1300nm, ST FX02 = 2 x 100FX - Multimode, 1300nm, SC FX11 = 2 x 100FX Multimode, 1300nm, LC FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ FX04 = 2 x 100FX - Singlemode, 1300nm, ST, 20km FX05 = 2 x 100FX - Singlemode, 1300nm, SC, 20km FX06 = 2 x 100FX - Singlemode, 1300nm, LC, 20km FX07 = 2 x 100FX - Singlemode, 1300nm, SC, 50km FX08 = 2 x 100FX - Singlemode, 1300nm, LC, 50km FX09 = 2 x 100FX - Singlemode, 1300nm, SC, 90km FX10 = 2 x 100FX - Singlemode, 1300nm, LC, 90km IRIG = 1 x IRIG-B in, BNC, 1 x IRIG-B out, BNC (S5 only) RS416P S6: PoE Ethernet Modules for Slots 6 PX01 =2 10/100 BaseTx PoE Ports
= None XX = Conformal Coating C01
Notes: 1. When IR or ID are ordered the IRIG module must be ordered for slot 5 2. IEEE 1588 Hardware Assist and Internal clock capable units are only available on units sold with the IRIG module

MOD: Manufacturing Modifications

www.RuggedCom.com

39

RuggedBackbone RX1500, RX1501

Features Port Options


Number of Ports

RX1500

Industrially Hardened Layer 3 Switch and Router

RX1501

Industrially Hardened Layer 3 Switch and Router

Up to 16 ports 100FX, Up to 24-ports 10/100TX, Up to 8 ports Gigabit Ethernet, Up to 4 T1/E1 ports Up to 18 RS232/422/485 Serial,All modules are field replaceable

Up to 4 10/100/1000 Base Tx ports or 36-10/100 Tx ports Up to 24 100FX or 4-optical Gigabit ports, Up to 30 RS232/422/485 Serial, Up to 4 T1/E1 ports

Serial Ports Port Type Fiber Optic Connectivity

Up to 16 Serial Ports, Software Selectable RS232/RS422/RS485, Db9 or RJ 45 connectors RJ45, Fiber ports, Copper ports, Serial ports, Pluggable Optics (SFP) 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC, 1000SX LC, 1000LX SC/LC

Fiber Mode
Multimode Singlemode Up to 2km Diff Range: 20/50/90km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay Lo Voltage: 9-72 VDC Hi Voltage: AC/DC: 88-300VDC or 85-264VAC 40W Max 5A@30VDC, 8A@250VAC

Switch Properties
ROXII Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1Q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), Broadcast Storm Filtering, SNTP, Modbus TCP. Simple plug and play operation, Port Rate Limiting, Port Mirroring, BGPv4, OSPFv2, RIP v1/2 Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SSL (128 bit encryption), MAC base port security, (802.1x), VLAN (802.1Q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 17.36 x 1.74 x 11.9 19 Rack Mount, DIN rail or Panel Mounted 5.2kg IP40 (1mm) Aluminum steel enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

40

RX1500 - ___ - _____ - ____ - ____ - ____ - ____ - ____ - ____ - ____ - _____ ST MNT PM1 PM2 SFT LM1 LM2 LM3 LM4 MOD
PM1 LM1 LM2 LM3 LM4 PM2

RX1500

RX1501 - ___ - _____ - ____ - ____ - ____ - ____ - ____ - ____ - ____ - ____ - _____ ST MNT PM1 SFT LM1 LM2 LM3 LM4 LM5 LM6 MOD
PM1 LM1 LM2 LM3 LM4 LM5 LM6

RX1501

ST: Switch Type Hardware = Layer 2 Switch L2 = Layer 3 Switch L3 Mount: Mounting Options = 19 Rack Mount Kit RM = No Mounting Option 00 PM1 and PM2: Power Modules = 88-300 VDC or 85-264VAC, screw terminal block HI = 88-300 VDC or 85-264VAC, pluggable terminal block HIP XXP = No Power Supply (PM2 only) SFT: Software L2SE = Layer 2 Standard Edition L3SE = Layer 3 Standard Edition

100BaseFX modules with 4 Ports 4FX11 = 4 x 100FX - Multimode, 1300nm, LC connectors, 2km 4FX03 = 4 x 100FX - Multimode, 1300nm, MTRJ connectors, 2km 4FX06 = 4 x 100FX - Singlemode, 1300nm, LC connectors, 20km 4FX08 = 4 x 100FX - Singlemode, 1300nm, LC connectors, 50km 4FX10 = 4 x 100FX - Singlemode, 1300nm, LC connectors, 90km Gigabit Ethernet Modules modules with 2 Ports 1 FG01 = 2 x 1000SX Multimode, 850 nm, LC, 500m FG02 = 2 x 1000LX Singlemode 1300 nm, SC, 10km FG03 = 2 x 1000LX Singlemode 1300 nm, LC, 10km FG04 = 2 x 1000LX Singlemode 1300 nm, SC, 25km FG05 = 2 x 1000LX Singlemode 1300 nm, LC, 25km FG50 = 2 x 1000LX SFP Blank(no optical transceiver) FG51 = 2 x 1000SX SFP Multimode, 850 nm, LC, 500m FG52 = 2 x 1000LX SFP Singlemode, 1310 nm, LC, 10km FG53 = 2 x 1000LX SFP Singlemode, 1310 nm, LC, 25km FG54 = 2 x 1000LX SFP Singlemode, 1550 nm, LC, 70km WAN Port Options 2 = Single T1/E1 via RJ45 (Channelized/Unchannelized) TC1 = Dual T1/E1 via RJ45 (Channelized/Unchannelized) TC2 = Quad T1/E1 via RJ45 (Channelized/Unchannelized) TC4 = Single E1 75 Ohms via BNC (Channelized/Unchannelized) E01 = Dual E1 75 Ohms via BNC (Channelized/Unchannelized) E02 MOD: Hardware Modifications = None XX = With Conformal Coating C01
Notes: 1. On the RX1501 these modules may only be selected for LM1 and LM2. 2. Only one T1/E1 module may be used per router.

LM1 through LM6 Line Modules


Blank Module = Blank Module XX Copper Ethernet Modules 6TX01 = 6 x 10/100TX RJ45 CG01 = 2x 10/100/1000TX RJ45 1 100BaseFX modules with 2 Ports 1 FX01 = 2 x 100FX - Multimode, 1300nm, ST connectors, 2km FX02 = 2 x 100FX - Multimode, 1300nm, SC connectors, 2km FX11 = 2 x 100FX - Multimode, 1300nm, LC connectors, 2km FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ connectors, 2km FX04 = 2 x 100FX - Singlemode, 1300nm, ST connectors, 20km FX05 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 20km FX06 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 20km FX07 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 50km FX08 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 50km FX09 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 90km FX10 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 90km

www.RuggedCom.com

41

RuggedBackbone RX1510, RX1511, RX1512

Features

Hardened Ethernet Switch and Router with Optional Redundant Power Supply

RX1510

RX1511

Hardened Ethernet Switch and Router Ideal for Pole & DIN Rail Mounting

RX1512

Hardened Ethernet Switch and Router Ideal for Pole & DIN Rail Mounting

Compact, Modular, Field Hot-Swappable Layer 3 Switching and Routing Platform with Integrated Cyber Security Appliance Functions

Port Options
Number of Ports Up to 24 10/100BaseTx, Up to 8 Gigabit Ports, Up to 4 T1/E1 ports, Up to 18 RS232/422/485, Up to 16 100BaseFx Ports RJ45, Fiber Port, Copper Port, Serial port 100FX ST/SC/LC/MTRJ, 1000SX LC, 1000LX SC/LC Up to 12 10/100TX or 8-100FX ports, Up to 4 Giga Ethernet Ports, Single/Dual/Quad T1/E1 modules Up to 12 10/100TX or 8-100FX ports, Up to 4 Gigabit Ethernet Ports,Single/Dual/Quad T1/E1 modules

Port Type Fiber Optic Connectivity

Fiber Mode
Multimode Singlemode Up to 2km 100FX 2km to 90km, Gigabit 500m to 70km

RuggedCom eRSTP
eRSTP Features eRSTP implements both STP and RSTP Worst-case fault recovery of 5ms times bridge diameter and allows rings of up to 160 switches

Power Supply
Power Range Power Consumption Critical Alarm Relay Low Voltage: 12-60 VDC High Voltage AC/DC: 88-300VDC & 85-264VAC 40W Max Max Voltage: 5A@30VDC, Max Current: 8A@250VAC Fixed Power Supply: Input voltage range of 9-72 VDC Fully integrated power supply

Switch Properties
ROXII Features Frame Relay Support Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1Q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), SNTP, Modbus TCP Broadcast Storm Filtering, SNTP, Modbus TCP.Simple plug and play operation, Port Rate Limiting, Port Mirroring, BGPv4, OSPFv2, RIP ISO and ITU compliant, network certified, ANSI T1.617 Annex D, Q.933 or LMI Local Signaling Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SSL (128 bit encryption), MAC base port security, (802.1x), VLAN (802.1Q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery (802.3ad)

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 9.36 x 8.16 x 4.83 DIN rail or Panel Mounted 10.3lbs IP40 (1mm) Alumnium enclosure 5lbs 5.95 x 7.66 x 4.83 4.4 x 7.31 x 4.83

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) Hazardous Locations: Class 1, Div 2

42

RX1510 - ___ - _____ - ____ - ____ - ____ - ____ - ____ - ____ - ____ - _____ ST MNT PM1 PM2 SFT LM1 LM2 LM3 LM4 MOD
RX1510 LM1 LM2 LM3 LM4 PM1 PM2

RX1511 - ___ - _____ - ____ - ____ - ____ - ____ - _____ ST MNT PM1 SFT LM1 LM2 MOD
RX1511 LM1 LM2 PM1

RX1512 - ___ - _____ - ____ - ____ - ____ - ____ - _____ ST MNT PS SFT LM1 LM2 MOD
RX1512 LM1 LM2

ST: Switch Type = 8 Gigabit Layer 2 Switch Fabric L2 = 8 Gigabit Layer 3 Switch Fabric L3 MNT: Mounting Options = DIN Rail Mounting DIN = No Mounting Option 00 PM1 and PM2: Power Modules = 88-300 VDC or 85-264VAC, screw terminal block HI = 88-300 VDC or 85-264VAC, pluggable terminal block HIP XXP = No Power Supply (PM2 only) PS: Fixed Power Supply (RX1512) = 9-72VDC, screw terminal block DC SFT: Software L2SE = Layer 2 Standard Edition L3SE = Layer 3 Standard Edition

100BaseFX modules with 4 Ports 4FX11 = 4 x 100FX - Multimode, 1300nm, LC connectors, 2km 4FX03 = 4 x 100FX - Multimode, 1300nm, MTRJ connectors, 2km 4FX06 = 4 x 100FX - Singlemode, 1300nm, LC connectors, 20km 4FX08 = 4 x 100FX - Singlemode, 1300nm, LC connectors, 50km 4FX10 = 4 x 100FX - Singlemode, 1300nm, LC connectors, 90km Gigabit Ethernet Modules modules with 2 Ports FG01 = 2 x 1000SX Multimode, 850 nm, LC, 500m FG02 = 2 x 1000LX Singlemode 1300 nm, SC, 10km FG03 = 2 x 1000LX Singlemode 1300 nm, LC, 10km FG04 = 2 x 1000LX Singlemode 1300 nm, SC, 25km FG05 = 2 x 1000LX Singlemode 1300 nm, LC, 25km FG50 = 2 x 1000LX SFP Blank(no optical transceiver) FG51 = 2 x 1000SX SFP Multimode, 850 nm, LC, 500m FG52 = 2 x 1000LX SFP Singlemode, 1310 nm, LC, 10km FG53 = 2 x 1000LX SFP Singlemode, 1310 nm, LC, 25km FG54 = 2 x 1000LX SFP Singlemode, 1550 nm, LC, 70km WAN Port Options 1 = Single T1/E1 via RJ45 (Channelized/Unchannelized) TC1 = Dual T1/E1 via RJ45 (Channelized/Unchannelized) TC2 = Quad T1/E1 via RJ45 (Channelized/Unchannelized) TC4 = Single E1 75 Ohms via BNC (Channelized/Unchannelized) E01 = Dual E1 75 Ohms via BNC (Channelized/Unchannelized) E02 MOD: Hardware Modifications None XX= CO1 = With Conformal Coating
Notes: 1. Only one T1/E1 module may be used per unit.

LM1 through LM4: Line Modules


Blank Module = Blank Module XX 10/100BaseTX and 10/100/1000BaseTX modules 6TX01 = 6 x 10/100TX RJ45 CG01 = 2x 10/100/1000TX RJ45 100BaseFX modules with 2 Ports FX01 = 2 x 100FX - Multimode, 1300nm, ST connectors, 2km FX02 = 2 x 100FX - Multimode, 1300nm, SC connectors, 2km FX11 = 2 x 100FX - Multimode, 1300nm, LC connectors, 2km FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ connectors, 2km FX04 = 2 x 100FX - Singlemode, 1300nm, ST connectors, 20km FX05 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 20km FX06 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 20km FX07 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 50km FX08 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 50km FX09 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 90km FX10 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 90km

www.RuggedCom.com

43

RuggedBackbone RX5000

Features Port Options


Number of Ports Serial Connectors Port Type Fiber Optic Connectivity

RX5000

Industrially Hardened Layer 3 Switch and Router

Up to 96 10/100TX ports, Up to 48 100FX optical ports, Up to 2 Gigabit Ethernet ports RS485/RS422/RS232 RJ45, Fiber port, Copper port 100FX ST/SC/LC/MTRJ, 1000SX LC, 1000LX SC/LC

Fiber Mode
Multimode Singlemode Up to 2km Diff Range: 20/50/90km

Power Supply
Power Range Power Consumption Critical Alarm Relay Hi Voltage: AC/DC: 88-300VDC or 85-264VAC 100W Max Max Current 2A@250VAC, 2A@30VDC

Switch Properties
ROXII Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1Q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), Broadcast Storm Filtering, SNTP, Modbus TCP. Simple plug and play operation, Port Rate Limiting, Port Mirroring, BGPv4, OSPFv2, RIP v1/2 Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SSL (128 bit encryption), MAC base port security, (802.1x), VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 17.36 x 6.9 x 11.89 19 Rack Mount, Panel Mounted Dependent on module selection IP40 (1mm) 18 AWG galvanized steel enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) Hazardous Locations: Class 1, Div 2

44

RX5000 - _____ - ______ - ____ - ____ - ___ - ___ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main MNT PM1 PM2 SM CM SFT L1 L2 L3 L4 L5 L6 MOD

PM1

L1

L2

L3

CM

SM

L4

L5

L6

PM2

MAIN: Ethernet and Power Connectors = Rack Front Mount, Interfaces and LEDs on Front F = Rack Rear Mount, no interfaces/LEDs on Front Panel R = Rack Rear Mount, Front panel with Power Terminal Blocks R2 MNT: Mounting Options = Panel Mount Kit PM = 19 Rack Mount Kit RM = No Mounting Option 00 PM1 and PM2: Power Modules 1 and 2 Power Modules for MAIN type: F and R* = 88-300VDC or 85-264VAC, screw terminal block HI = Blank Module (PM2 only) XX Power Modules for MAIN type: R2 = 88-300VDC or 85-264VAC, supports Terminal Block on Front HIF = Blank Module (PM2 only) XX SM: Switch Module: Layer 2 /8 Gigabit Throughput Switch Module Options SM01 = with no uplink ports SM02 = with 2x 10/100/1000TX RJ45 ports SM04 = with 2x 1000SX Multimode, 850nm, LC, 500m SM05 = with 2x 1000LX Singlemode, 1310nm, SC, 10km SM06 = with 2x 1000LX Singlemode, 1310nm, LC, 10km SM07 = with 2x 1000LX Singlemode, 1310nm, SC, 25km SM08 = with 2x 1000LX Singlemode, 1310nm, LC, 25km SM09 = with 2x 1000LX SFP Blank ( no transceivers ) Layer 3 /8 Gigabit Throughput Switch Module Options SM31 = with no uplink ports SM32 = with 2x 10/100/1000TX RJ45 ports SM34 = with 2x 1000SX Multimode, 850nm, LC, 500m SM35 = with 2x 1000LX Singlemode, 1310nm, SC, 10km SM36 = with 2x 1000LX Singlemode, 1310nm, LC, 10km SM37 = with 2x 1000LX Singlemode, 1310nm, SC, 25km SM38 = with 2x 1000LX Singlemode, 1310nm, LC, 25km SM39 = with 2x 1000LX SFP Blank (no transceivers) CM: Control Module CM01: Control Module SFT: Software L2SE = Layer 2 Standard Edition L3SE = Layer 3 Standard Edition

L1 through L6: Line Modules


= Blank Module XX

Blank Module

10/100 BaseTX 16 Ports 16TX01 = 16x 10/100TX RJ45 100FX modules with 8 Ports 8FX01 = 8x 100FX Multimode, 1310nm, ST, 2km 8FX02 = 8x 100FX Multimode, 1310nm, SC, 2km 8FX11 = 8x 100FX Multimode, 1310nm, LC, 2km 8FX03 = 8x 100FX Multimode, 1310nm, MTRJ, 2km 8FX04 = 8x 100FX Singlemode, 1310nm, ST, 20km 8FX05 = 8x 100FX Singlemode, 1310nm, SC, 20km 8FX06 = 8x 100FX Singlemode, 1310nm, LC, 20km 8FX07 = 8x 100FX Singlemode, 1310nm, SC, 50km 8FX08 = 8x 100FX Singlemode, 1310nm, LC, 50km 8FX09 = 8x 100FX Singlemode, 1310nm, SC, 90km 8FX10 = 8x 100FX Singlemode, 1310nm, LC, 90km 100FX modules with 4 Ports 4FX01 = 4x 100FX Multimode, 1310nm, ST, 2km 4FX02 = 4x 100FX Multimode, 1310nm, SC, 2km 4FX11 = 4x 100FX Multimode, 1310nm, LC, 2km 4FX03 = 4x 100FX Multimode, 1310nm, MTRJ, 2km 4FX04 = 4x 100FX Singlemode, 1310nm, ST, 20km 4FX05 = 4x 100FX Singlemode, 1310nm, SC, 20km 4FX06 = 4x 100FX Singlemode, 1310nm, LC, 20km 4FX07 = 4x 100FX Singlemode, 1310nm, SC, 50km 4FX08 = 4x 100FX Singlemode, 1310nm, LC, 50km 4FX09 = 4x 100FX Singlemode, 1310nm, SC, 90km 4FX10 = 4x 100FX Singlemode, 1310nm, LC, 90km Gigabit Ethernet Modules with 4 Ports 4CG01 = 4x 10/100/1000TX RJ45 4FG01 = 4x 1000SX Multimode, 850nm, LC, 500m 4FG02 = 4x 1000LX Singlemode, 1310nm, SC, 10km 4FG03 = 4x 1000LX Singlemode, 1310nm, LC, 10km 4FG04 = 4x 1000LX Singlemode, 1310nm, SC, 25km 4FG05 = 4x 1000LX Singlemode, 1310nm, LC, 25km 4FG50 = 4x 1000LX SFP Blank (no transceivers) MOD: Hardware Modifications = No Hardware modifications XX = Conformal Coating C01
* PM1 may not be blank

Any of the modules , Power, Control, Switch or Line Modules, may be ordered as individual parts. RX5000PN - ____ - _____ PT MOD PT: Individual part To be Ordered Part may be chosen from Main, MNT or any module from the RX5000 order codes page. The

www.RuggedCom.com

45

RuggedBackbone MX5000

Features Port Options


Number of Ports Port Type Fiber Optic Connectivity

MX5000 / RuggedBackbone with RuggedEnclosure MX5000RE


MIL-STD Industrially Hardened Layer 3 Switch and Router

Up to 96 10/100TX + 2 10/100TX copper ports, Up to 48 100FX optical ports, Up to 2 Gigabit Ethernet ports RJ45, Fiber port, Copper port 100FX ST/SC/LC/MTRJ, 1000SX LC, 1000LX SC/LC

Fiber Mode
Multimode Singlemode Up to 2km Diff Range: 20/50/90km

Power Supply
Power Range Power Consumption Critical Alarm Relay Hi Voltage: AC/DC: 88-300VDC or 85-264VAC 100W Max Max Current 2A@250VAC, 2A@30VDC

Switch Properties
ROXII Features Management Cyber Security Features STP Details QoS(802.1p), VLAN(802.1Q), GVRP, GMRP, IGMP Snooping, Link aggregation (802.3ad), Broadcast Storm Filtering, SNTP, Modbus TCP. Simple plug and play operation, Port Rate Limiting, Port Mirroring, BGPv4, OSPFv2, RIP v1/2 Web, Telnet, CLI, SNMP v1/v2c/v3, RMON SSH/SSL (128 bit encryption), MAC base port security, (802.1x), VLAN (802.1q), SNMP v3 MSTP 802.1Q-2005(802.1s), RSTP (802.1w) and eRSTP network fault recovery

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 17.36 x 6.9 x 11.89 19 Rack Mount, Panel Mounted Dependent on module selection IP40 (1mm) 18 AWG galvanized steel enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge MIL-STD Testing EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line MIL-STD 901D Shock, MIL-STD 167 Vibration, MIL-STD 461 EMI, MIL-STD 1399 Magnetic Field IEEE 1613 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic)

46

MX5000 - _____ - ______ - ____ - ____ - ___ - ___ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main MNT PM1 PM2 SM CM SFT L1 L2 L3 L4 L5 L6 MOD

PM1

L1

L2

L3

CM

SM

L4

L5

L6

PM2

MAIN: Ethernet and Power Connectors = Front Panel Blank, no interfaces/LEDs 1 MR MR1 = Front panel with Fan Controller and Power Terminal Blocks MR2 = Front Panel with Power Terminal Blocks MNT: Mounting Options = Panel Mount Kit PM = 19 Rack Mount Kit RM = No Mounting Option 00

SFT: Software L2SE = Layer 2 Standard Edition L3SE = Layer 3 Standard Edition Blank Module = Blank Module XX

L1 through L6: Line Modules

PM1 and PM2: Power Modules 1 and 2*


Power Modules for MAIN type: MR, MR2 = 88- 300VDC or 85 - 264VAC, screw terminal block1 MHI = Blank Module XX Power Modules for MAIN type: MR1 and MR2 MHIF = 88- 300VDC or 85 - 264VAC,
= Blank Module XX
supports Terminal Block on Front

10/100 BaseTX 8 Ports M8TX02 = 8x 10/100 BaseTX MicroD Ports 100FX modules with 8 Ports M8FX01 = 8x 100FX Multimode, 1310nm, ST, 2km M8FX11 = 8x 100FX Multimode, 1310nm, LC, 2km M8FX04 = 8x 100FX Singlemode, 1310nm, ST, 20km M8FX06 = 8x 100FX Singlemode, 1310nm, LC, 20km M8FX08 = 8x 100FX Singlemode, 1310nm, LC, 50km M8FX10 = 8x 100FX Singlemode, 1310nm, LC, 90km 100FX modules with 4 Ports M4FX01 = 4x 100FX Multimode, 1310nm, ST, 2km M4FX11 = 4x 100FX Multimode, 1310nm, LC, 2km M4FX04 = 4x 100FX Singlemode, 1310nm, ST, 20km M4FX06 = 4x 100FX Singlemode, 1310nm, LC, 20km M4FX08 = 4x 100FX Singlemode, 1310nm, LC, 50km M4FX10 = 4x 100FX Singlemode, 1310nm, LC, 90km Gigabit Ethernet Modules with 4 Ports M4CG02 = 4x 10/100/1000TX microD M4FG01 = 4x 1000SX Multimode, 850nm, LC, 500m M4FG03 = 4x 1000LX Singlemode, 1310nm, LC, 10km M4FG05 = 4x 1000LX Singlemode, 1310nm, LC, 25km MOD: Hardware Modifications = No Hardware modifications XX = Conformal Coating C01
* PM1 must not be blank ComingSoon 1 Consult Factory for availibility

SM: Switch Module Layer 2 /8 Gigabit Throughput Switch Module Options MSM01 = with No Ports on Switch Module MSM04 = with 2x 1000SX Multimode, 850nm, LC, 500m MSM06 = with 2x 1000LX Singlemode, 1310nm, LC, 10km MSM08 = with 2x 1000LX Singlemode, 1310nm, LC, 25km Layer 3 /8 Gigabit Throughput Switch Module Options MSM31 = with No Ports on Switch Module MSM34 = with 2x 1000SX Multimode, 850nm, LC, 500m MSM36 = with 2x 1000LX Singlemode, 1310nm, LC, 10km MSM38 = with 2x 1000LX Singlemode, 1310nm, LC, 25km CM: Control Module MCM01: Control Module

Any of the modules , Power, Control, Switch or Line Modules, may be ordered as individual parts. MX5000PN - ____ PT PT: Individual part To be Ordered Part may be chosen from Main, MNT or any module from the MX5000 order codes page. The

www.RuggedCom.com

47

RuggedEnclosure

Features Key Features

RuggedBackbone with RuggedEnclosure MX5000RE

Tough Aluminum enclosure to absorb shock and vibration, EMI glass allows internal visibility of electronics. Welded 6061-T4 3/16 aluminum construction Welded 6061-T6 1/2 aluminium mounting brackets with three 1/2 mounting holes withstandMIL 901D hard mounting (IP 65) Ample room for on front panel application specific labels. Configurable patch panel allows up to 64 MIL grade circular connectors for both copper and fiber media Hard mounted brackets fits standard 19 rack mount equipment. Dual internal MIL grade high reliability fans minimize internal temperature gradient with no outside air exchange Integrated cable management for strain relief, Extrusion fins inside and outside for optimal heat transfer

Enhanced Protection through the RuggedEnclosure The RuggedEnclosure is a tough aluminum enclosure built to improve the MX5000s already impressive shock and vibration performance and even further reduce, the already low, electronic emissions from the MX5000. The RuggedEnclosure uses EMI Glass and provides a patch panel with EMI gaskets to keep emissions at a minimum. This hard mounted enclosure when coupled with the MX5000 continues RuggedComs tradition of pioneering advanced networking solutions specifically for the harsh environments found in Military applications. Full descriptions of both the RuggedEnclosure and the RuggedBackbone MX5000 are available on their respective data sheets.

Order your RuggedBackbone MX5000 pre-installed and cabled within the RuggedEnclosure for the industrys most complete MIL-STD Ethernet switch offering.

48

RuggedCELL EVDO for RX1000 The cellular modem option for the RuggedRouter , enables RuggedCell users to extend network boundaries, reaching remote sites with broadband throughputs and built in quality ofservice. The router is equipped with a cellular modem, allowing users to operate on a number of approved cellular networks. The cellular modem allows connections to be made over cellular radio data link using the Point- to Point Protocol (PPP). Overall Features Optional card for RuggedRouter RX 1x00 Series IS-95A, 1xRTT, 1xEV-DO REV 0, 1xEV-DO REV A RuggedRated reliability and protection Performance Data Speed: up to 3.1 mb/s downstream, 1.8 mb/s upstream Frequency Bands: Dual Band 800/1900 MHz Receive Diversity Support Radio parameters Output power: Up to 25 dBm Sensitivity: < -107 dBm Rx Antenna Parameters Antenna: 5.1 dBi (Cellular band), 4.15 dBi (PCS band) Antenna Connectors: (2x) 50 ohm SMA female

RuggedCELL HSPA for RX1000 The cellular modem option for the RuggedRouter , enables RuggedCell users to extend network boundaries, reaching remote sites with broadband throughputs and built in quality ofservice. The router is equipped with a cellular modem, allowing users to operate on a number of approved cellular networks. The cellular modem allows connections to be made over cellular radio data link using the Point- to Point Protocol (PPP) PPP. Overall Features Optional card for RuggedRouter RX 1x00 Series HSUPA, HSDPA, UMTS, EDGE, GPRS, GSM RuggedRated reliability and protection Performance Data Speed2: up to 7.2 mb/s downstream, 2 mb/s upstream Frequency Bands: GSM/GPRS: 850/900/1800/1900 MHz WCDMA/HSDPA/HSUPA: 800/850/1900/2100 MHz Receive Diversity Support Radio parameters Output power: Up to 32 dBm Sensitivity: < -106 dBm Rx Antenna Parameters Antenna Gain: 5 dBi (Cellular band), 4 dBi (PCS band) Max Antenna Connectors: (2x) 50 ohm SMA female

www.RuggedCom.com

49

RuggedRouter Cyber Security Appliances

Features Port Options


Number of Ports

RX1000
Ethernet options (Up to 4 ports): 10/100BaseTX, 100BaseF, Cellular Modem (GSM-EDGE, EVDO, HSPA), WAN Port Options (Up to 8 ports): (T1/ E1, DSL, T3 DS3, 56 Kbps DDS)

RX1000P
Ethernet options (Up to 4 ports): 10/100BaseTX, 100BaseFX, 4-10/100BaseTX 802.3af (PoE) compliant ports, Cellular Modem (GSM-EDGE, HSPA, EVDO), Multiple WAN Ports: (8-T1/E1, DSL, T3 DS3, 56 Kbps DDS)

RX1100
Ethernet options (Up to 4 ports): 10/100BaseTX, 100BaseFX, Cellular Modem (GSM-EDGE, HSPA, EVDO), WAN Port Options (Up to 8 ports): (T1/ E1, DSL, T3 DS3, 56 Kbps DDS),

Serial Ports Fiber Optic Connectivity Precision Timing Protocol

4 or 8 ports , Software selectable RS232/RS422/RS485, RJ45 connector 10FL ST, 100FX ST/SC/LC/MTRJ, 100FX ST/SC/LC Built-in GPS, Antenna Input NTP Server and Client IRIG-B (user selectable)

Fiber Mode
Multimode Singlemode Up to 2km 20km to 90km

Power Supply
Power Range 24VDC: 10-36 VDC, 48VDC: 36-72 VDC High Voltage AC/DC: 88-300VDC & 85-264VAC (Max) 25W (Max) 1A@30VDC 24VDC: 10-36 VDC, 48VDC: 36-72 VDC High Voltage AC/DC: 88-300VDC & 85-264VAC (Max), PoE Power Supply48VDC: 36-59VDC 0.6A 24VDC: 10-36 VDC, 48VDC: 36-72 VDC High Voltage AC/DC: 88-300VDC & 85-264VAC (Max)

Power Consumption Critical Alarm Relay

Router Properties
Management Protocols Frame Relay Support Cyber Security Features Web, Telnet, CLI, SNMP v1/v2c/v3, RMON Frame Relay RFC 1490FC 1294, PPP RFC 1661/1332/1321/1334, PAP, CHAP Authentication, PPPoE over DSL IP: Routing, VRRP, OSPF, RIP, DHCPAgent(Option 82 Capable),Traffic prioritization, NTP Server, IP Multicast Routing ISO and ITU compliant, network certified ANSI T1.617 Annex D, Q.933 or LMI Local Signaling Integrated Router/Firewall/VPN Stateful Firewall with NAT, Full IPSec VPN, VPN 3DES, AES128, AES256 support RADIUS centralized password Intrusion Detection Services (IDS), RuggedCom Gauntlet for NERC CIP Cyber Security compliance, RADIUS centralized password

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 1.74 x 17.25 x 11.9 19 Rack Mount, DIN rail or Panel Mounted 4.5kg IP40 (1mm) 18 AWG Galvanized Steel Enclosure

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems)

50

RuggedRouter RX1000, RX1000P, RX1100

RX1000 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 MOD
S1 S2 S3 S4 S5 S6

RX1000P - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 MOD
S1
P

S3 S4

S5 S6

S2

RX1100 - _____ - ______ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - _____ Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 MOD
S1 S2 S3 S4 S5 S6

Main: Ethernet and Power Connectors = Ethernet on rear; LED panel on front; power connector on rear R = Ethernet on front; LED panel on front; power connector on rear F = Ethernet on rear; LED panel on top; power connector on rear B = Ethernet on front; LED panel on top; power connector on rear T Mount: Mounting Options = 19 Rack Mount Kit RM = DIN and Panel Mount Kit DP = 19 Rack, DIN, and Panel Mount Kit RD = No Mounting Option 00 RX1000/RX1100 PS1,PS2: Power Supply 1 and Redundant Power Supply RX1000P PS1: Power Supply 1 = 24VDC (10-36VDC), screw terminal block 24 = 48VDC (36-59VDC), screw terminal block 48 = 88-300VDC or 85-264VAC, screw terminal block HI = 24VDC (9-36VDC), pluggable terminal block 24P = 48VDC (36-59VDC), pluggable terminal block 48P = 88-300VDC or 85-264VAC, pluggable terminal block HIP = No Power Supply (PS2 Only) XX RX1000P-PS2: RX1000P PoE Power Supply 48PoE = 48VDC (36-59VDC) PoE Power Supply S1: Modules for Slot 1 = Empty XX W10 = Cellular Modem (GSM-EDGE) (5)(6) S2: Modules for Slot 2 = Empty XX = V90 Modem M1 = RS232 External Modem Interface M2 RX1000P S3: RX1000P Ethernet Modules for Slot 3 PX01 = 2x 10/100 Base TX PoE Ports RX1000P S4: Ethernet Module for Slot 3 RX1000/RX1100 S3,S4: Ethernet Modules for Slots 3 and 4 (2)(3) XXXX = Empty TX01 = 2 x 10/100Tx RJ45 FX01 = 2 x 100FX - Multimode, 1300nm, ST connectors

FX02 = 2 x 100FX - Multimode, 1300nm, SC connectors FX11 = 2 x 100FX - Multimode, 1300nm, LC connectors FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ connectors FX04 = 2 x 100FX - Singlemode, 1300nm, ST connectors, 20km FX05 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 20km FX06 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 20km FX07 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 50km FX08 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 50km FX09 = 2 x 100FX - Singlemode, 1300nm, SC connectors, 90km FX10 = 2 x 100FX - Singlemode, 1300nm, LC connectors, 90km

S5 and S6: RX1000 Modules for Slots 5 and 6 (4) XXX = Empty = Single T1/E1 Channelized/Unchannelized TC1 = Dual T1/E1 Channelized/Unchannelized TC2 = Quad T1/E1 Channelized/Unchannelized TC4 DS3 = Clear Channel T3 DS3 card = DSL D01 = 56 kBbps DDS DSU/CSU D02 = Precision Time Protocol (PTP) Card: GPS, NTP, IRIG-B, TS1
= 4 x RS232/RS422/RS485 via RJ45 S01 = Synchronous Dual Serial Card Dual Serial DB25 Interface (9) S02 W11 = Cellular Modem GSM/EDGE/HSPA (6)(7) W20 = Cellular Modem EVDO rev A Verizon US (6)(8)
IEEE 1588 Time Synchronization (1)

MOD: Hardware Modifications = No Hardware Modifications XX = Conformal Coating C01


Notes: 1 Only one (1) GPS card can be configured per router; see PTP card datasheet for more information. 2 One Ethernet module must be ordered with each router. 3 S3 must be populated before S4 4 S5 must be populated before S6 5 This module has an operating temperature rage of -30C to 50C 6 Only one cellular modem can be installed on the RuggedRouter 7 Supported operating temperature range is pending final testing and excludes carrier provided SIM. Please contact your regional sales manager for information on carrier approval for this option. 8 This modules supported operating temperature range is pending final testing 9 Consult factory for availibility

www.RuggedCom.com

51

RuggedPower Power Injector

Features
Application

RP100
Capable of supplying up to 50W of power at 48VDC, with a wide selection of input voltage (Rugged PoE injector)

RP110
Capable of supplying up to 40W of power at 48VDC, with a wide selection of input supply voltages

Industrial Design
Ports eliminates need for crossover cables Dual voltage Inputs Configuration free, plug and play operation LED indicators for link, activity, and speeds LED aids in field trouble-shooting Panel or DIN mounting Lightweight Cast Aluminum Enclosure

Port Options
Number of Ports Port Types 2 X 10/100 Tx Port, Standard 802.3 at PoE Copper Port 1 RS485/RS422 port and 1 independent RS232 port, 1 IEEE 802.3at compliant output, 1 IRIG-B Output

Power Supply
Input voltages of 10-60 VDC and 88-300 VDC or 85-264 VAC for worldwide operability Integrated power supply eliminates need for an external power transformer Screw down terminal blocks ensure reliable maintenance free connections, CSA/UL 60950 safety approved to +85 C

Approvals
ISO: Designed and manufactured using a ISO9001:2000 certified quality program CE Making Emissions: FCC Part 15 (Class A), En55022 (CISPR22 Class A) Safety: cCSAus (Compliant with CSA C22.2 No. 60950, Ul60950, EN60950

Temperature Range
Max Operating Range Relative Humidity -40 ~ +85C (No Fans) 5% ~ 95%

Physical
Dimension Mount Weight Ingress Protection Enclosure 4.625 x 2.225 x 3.75 Panel or DIN mounting 2.2lbs / 1.0kg IP40 (1mm) Lightweight Cast Aluminum

EMI Test
EN 61000-4-2 ESD EN 61000-4-3 RFI EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 RFI EMI Immunity and Environmental compliance +/-8kV(Enclosure Contact), +/-15kV(Enclosure Air) 20 V/m A.C./D.C Power Ports +/-4kV, Signal ports+/-4kV @ 2.5kHz Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line, D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line, A.C. Power ports +/4kV line-to-earth, +/- 2kV line-to-line 10V@0.5-80 MHz IEEE 1613 (Electrical Utility Substations) IEEE 61800-3 Industrial (Variable Speed Drive Systems) NEMA TS-2 (Traffic Control Equipment) IEC 61850-3 (Electrical Utility Substations) IEC 61000-6-2 Industrial (Generic)

52

RuggedPower RP100, RP110

RP100 - _____ - _____ - _____ PS PD MOD PS: Power Supply 88-300VDC or 85-264VAC HI= 10-60 VDC LO= PD: Power Delivery = Standard 802.3at AT = RuggedMax Power Delivery (RuggedMax devices only) RM MOD: Manufacturing Modifications = None XX = Conformal Coating C01 Mounting Options rail mounting is standard DIN Panel mounting, order P/N 41-12-0006 For

RP110 - _____ - _____ - _____ PS PD MOD PS: Power Supply 88-300VDC or 85-264VAC HI= 10-60 VDC LO= PD: Power Delivery = Standard 802.3at AT = RuggedMax Power Delivery (RuggedMax devices only) RM MOD: Manufacturing Modifications = None XX = Conformal Coating C01 Mounting Options rail mounting is standard DIN Panel mounting, order P/N 41-12-0006 For

www.RuggedCom.com

53

RuggedMAX WiMAX Broadband Technology

Features
Number of Antennas

WiMAX Vehicular Subscriber Unit Profile (MIMO) 2

WiN5100

WiN5200

WiMAX Subscriber Unit

Radio and Modem


Frequency WiN5114: 1350 MHz to 1525 MHz WiN5118: 1800 MHz to 1830 MHz WiN5125: 2496 MHz to 2690 MHz WiN5135: 3300 MHz to 3800 MHz TDD IEEE802.16-2005 (16e OFDMA) Wave 2 Profile (MIMO) 3.5, 5, 7,10 MHz External RF ports 0.25 MHz 23 dBm +/-1dB maximum QPSK, 16QAM, 64QAM 24 dBm +/-1dB for 64QAM 5\6 3.5, 5, 7, 10 MHz Integrated Dual Slant Antenna WiN5214: 1350 MHz to 1525 MHz WiN5218: 1800 MHz to 1830 MHz WiN5235: 3300 MHz to 3800 MHz WiN5235: 3300 MHz to 3800 MHz

Operation Mode Radio Access Method Compatibility Channel Bandwidth Antenna Support Frequency Resolution Output Power (Average) Modulation

Power Supply
Power Source Power Consumption 10-30VDC car power 8W Typical 48VDC from the indoor

Data Communication
Ethernet Port Ethernet Standard Traffic Classification Max User Throughput 10/100 Mbps, Half/Full, Duplex with Auto Nego IEEE 802.3 CSMA/CD DSCP/IP TOS field, IP Protocol/Next Header field, IP masked Source Address, IP Destination Address, Protocol source port range, Protocol destination port range, Source MAC address (SA mode), Destination MAC address (SA mode), VLAN ID (SA mode), Ethertype (SA mode) DL: 26Mbps, UL: 10Mbps

Configuration and Management


Local Management Remote Management SNMP Agent Authentication Software Upgrade Remote Configuration Telnet, SNMPv2 & Web Browser SNMPv2 over wireless via the base station SNMP ver 2 client: MIB II (RFC 1213), Private Win-Max MIBs EAP-TTLS:Device: X509 digital certificate, User: MS-CHAP FTP FTP

Mechanical, Electrical & Environmental


Dimensions Weight Operating Temperature Operating Humidity 226 x 92 x 89 mm 1.5 kg -40C to +75C 5% - 95% Non-Condensing 224 x 92 x 61 mm

54

Features
Number of Antennas

High Power WiMAX Base Station 2

WiN7000

WiN7200

WiMAX Base Station

Radio and Modem


Frequency WiN7025: 2496 MHz to 2690 MHz WiN7035: 3400 MHz to 3600 MHz WiN7013: 1350 MHz to 1400 MHz WiN7015: 1400 MHz to 1520 MHz WiN7018: 1800 MHz to 1830 MHz TDD IEEE802.16-2005(16e OFDMA) WiMAX Forum Wave 2 Profile 3.5, 5, 7,10 MHz 2x2, STC/MIMO-SM 0.25 MHz Convolution Code and Turbo Code 2 X 36 dBm QPSK, 16QAM, 64QAM 2 X 27 dBm WiN7225 2496 MHz to 2690 MHz WiN7235 3400 MHz to 3600 MHz WiN7237 3600 MHz to 3720 MHz

Operation Mode Radio Access Method Compatibility Channel Bandwidth Antenna Support Frequency Resolution FEC Output Power (Average) Modulation

Power Supply
Power Source Power Consumption 85 - 265 VAC 120 Watt max 30 Watt max

Data Communication
Ethernet Port Ethernet Standard FFT 10/100BaseT Half / full Duplex IEEE 802.3 CSMA/CD IEEE 802.3 CSMA/CD 512/1024 FFT points

Configuration and Management


Local Management Remote Management SNMP Agent Authentication Software Upgrade Remote Configuration Web GUI Management SNMP SNMP Agent SNMP ver 2 client: MIB II EAP TLS/TTLS(MD5, MS-CHAPv2) Device: X.509 digital certificate FTP FTP

Mechanical, Electrical & Environmental


Dimensions Weight Operating Temperature Operating Humidity 60 cm X 27cm X 10 cm <4Kg -40C to +55C 5% - 95% Non Condensing -40C to +65C 24cm x 20cm x 4cm

www.RuggedCom.com

55

56

Rugged Communications Networking Solutions for Harsh Environments

RuggedCom Inc. 300 Applewood Crescent Concord, Ontario, Canada L4K 5C7 Tel: +1 (905) 856-5288 Fax: +1 (905) 482-2156 Toll Free: 1 (888) 264-0006 www.RuggedCom.com RuggedInfo@RuggedCom.com

2010 RuggedCom Inc. RuggedSwitch is a trademark of RuggedCom Inc. Ethernet is a trademark of the Xerox Corporation. All specifications in this document are subject to change without notice. Rev 1g