You are on page 1of 13

Coiled Tubes

Material Specification HS-70TM


HS-70 CMTM
(Continuously milled tubing)

HS-70 WTM
(Butt welded tube sections)

PHYSICAL PROPERTIES

Minimum yield strength 70,000 psi


Minimum tensile strength 80,000 psi
Minimum Elongation 30%
Maximum Hardness 22C Rockwell

CHEMICAL COMPOSITION - %

Carbon 0.10 0.15 range


Manganese 060 0.90 range
Phosphorus 0.30 max
Sulfur 0.005 max
Silicon 0.30 0.50 range
Chromium 0.45 0.70 range
Copper 0.40 max
Nickel 0.25 max

STEEL ALLOY DESCRIPTION

A-606 type 4 modified

CONTACT INFO
Tenaris Coiled Tubes
8615 E. Sam Houston Pkwy N.
77044 Houston Texas USA
coiledtubesales@tenaris.com
(1) 281 458 2883 tel
(1) 281 458 2886 fax

HS-70 GRADE*
DIMENSIONS
(Inches)

NOMINAL
WEIGHT
Lbs. / ft.

O.D.
SPECIFIED

O.D.
(mm)

WALL
SPECIFIED

WALL
(mm)

WALL
MINIMUM

I.D.
CALCULATED

1.000

25.4

1.250

31.8

1.500

38.1

1.750

44.5

2.000

50.8

2.375

60.3

0.080
0.087
0.095
0.102
0.109
0.080
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

2.03
2.21
2.41
2.59
2.77
2.03
2.21
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.076
0.083
0.090
0.097
0.104
0.076
0.083
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.840
0.826
0.810
0.796
0.782
1.090
1.076
1.060
1.046
1.032
1.018
1.000
0.982
0.960
0.938
0.900
1.310
1.296
1.282
1.268
1.250
1.232
1.210
1.188
1.150
1.120
1.532
1.518
1.500
1.482
1.460
1.438
1.400
1.370
1.342
1.782
1.768
1.750
1.732
1.710
1.688
1.650
1.620
1.592
2.125
2.107
2.085
2.063
2.025
1.995
1.967

0.788
0.850
0.920
0.981
1.040
1.002
1.083
1.175
1.254
1.332
1.408
1.506
1.601
1.715
1.827
2.014
1.429
1.527
1.623
1.719
1.840
1.960
2.104
2.245
2.483
2.665
1.915
2.029
2.175
2.318
2.492
2.662
2.951
3.173
3.377
2.207
2.340
2.509
2.677
2.880
3.080
3.419
3.682
3.923
3.011
3.215
3.462
3.706
4.122
4.445
4.742

TUBE LOAD BODY


(Lbs.)

INTERNAL
PRESSURE (psi)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. Ibs.)

INTERNAL
CAPACITY
per 1000 ft.

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

GALLONS

BARRELS

16,200
17,500
18,900
20,100
21,400
20,600
22,300
24,100
25,800
27,400
28,900
30,900
32,900
35,200
37,500
41,400
29,400
31,400
33,300
35,300
37,800
40,300
43,200
46,100
51,000
54,700
39,300
41,700
44,700
47,600
51,200
54,700
60,600
65,200
69,400
45,300
48,100
51,500
55,000
59,200
63,300
70,200
75,600
80,600
61,900
66,000
71,100
76,100
84,700
91,300
97,400

18,500
20,000
21,600
23,000
24,400
23,500
25,400
27,600
29,400
31,300
33,100
35,300
37,600
40,300
42,900
47,300
33,500
35,800
38,100
40,300
43,200
46,000
49,400
52,700
58,300
62,600
45,000
47,600
51,100
54,400
58,500
62,500
69,300
74,500
79,300
51,800
54,900
58,900
62,800
67,600
72,300
80,300
86,400
92,100
70,700
75,500
81,300
87,000
96,800
104,300
111,300

9,400
10,300
11,100
11,900
12,700
7,600
8,300
9,000
9,600
10,300
11,000
11,800
12,600
13,500
14,400
16,100
7,500
8,100
8,600
9,200
9,900
10,600
11,300
12,100
13,600
14,600
7,400
7,900
8,600
9,100
9,800
10,500
11,700
12,600
13,600
6,500
6,900
7,500
8,000
8,600
9,200
10,300
11,100
12,000
6,300
6,700
7,300
7,800
8,700
9,400
10,200

10,500
11,400
12,300
13,300
14,200
8,400
9,200
9,900
10,700
11,400
12,200
13,100
14,000
15,000
16,000
17,900
8,300
9,000
9,600
10,200
11,000
11,700
12,600
13,500
15,100
16,200
8,200
8,800
9,500
10,100
10,900
11,600
13,100
14,000
15,100
7,200
7,700
8,300
8,900
9,500
10,200
11,500
12,300
13,300
7,000
7,500
8,100
8,600
9,700
10,500
11,300

0.221
0.239
0.257
0.275
0.293
0.280
0.304
0.328
0.351
0.374
0.397
0.426
0.451
0.482
0.512
0.568
0.399
0.428
0.456
0.484
0.520
0.552
0.590
0.629
0.699
0.746
0.538
0.572
0.614
0.652
0.699
0.745
0.831
0.888
0.953
0.619
0.659
0.709
0.753
0.807
0.861
0.962
1.029
1.106
0.850
0.904
0.970
1.035
1.158
1.241
1.335

0.565
0.546
0.528
0.510
0.493
0.947
0.923
0.899
0.876
0.853
0.830
0.801
0.776
0.745
0.715
0.659
1.368
1.340
1.311
1.283
1.247
1.215
1.177
1.139
1.068
1.021
1.867
1.834
1.791
1.753
1.706
1.660
1.575
1.517
1.453
2.522
2.483
2.433
2.389
2.334
2.280
2.180
2.112
2.036
3.580
3.527
3.460
3.395
3.272
3.189
3.095

319
341
362
382
401
522
561
598
633
668
700
741
775
815
853
919
893
949
1,003
1,055
1,120
1,175
1,242
1,305
1,416
1,486
1,407
1,483
1,579
1,660
1,759
1,854
2,024
2,132
2,250
1,879
1,985
2,116
2,230
2,368
2,501
2,741
2,897
3,067
3,072
3,243
3,452
3,655
4,025
4,266
4,533

344
370
395
420
443
555
599
642
683
724
764
813
856
907
956
1,044
947
1,011
1,074
1,135
1,211
1,278
1,358
1,436
1,577
1,668
1,492
1,579
1,689
1,784
1,901
2,014
2,221
2,356
2,506
1,979
2,097
2,245
2,375
2,534
2,690
2,975
3,163
3,372
3,229
3,421
3,656
3,886
4,313
4,595
4,913

28.79
27.84
26.77
25.85
24.95
48.47
47.24
45.84
44.64
43.45
42.28
40.80
39.34
37.60
35.90
33.05
70.02
68.53
67.06
65.60
63.75
61.93
59.74
57.58
53.96
51.18
95.76
94.02
91.80
89.61
86.97
84.37
79.97
76.58
73.48
129.56
127.53
124.95
122.39
119.30
116.25
111.08
107.08
103.41
184.24
181.13
177.37
173.64
167.31
162.38
157.86

0.69
0.66
0.64
0.62
0.59
1.15
1.12
1.09
1.06
1.03
1.01
0.97
0.94
0.90
0.85
0.79
1.67
1.63
1.60
1.56
1.52
1.47
1.42
1.37
1.28
1.22
2.28
2.24
2.19
2.13
2.07
2.01
1.90
1.82
1.75
3.08
3.04
2.97
2.91
2.84
2.77
2.64
2.55
2.46
4.39
4.31
4.22
4.13
3.98
3.87
3.76

*Selected coiled tubing data


(70 Kpsi Min. Yield Strength; 80 Kpsi Min. Tensile Strength; 30 % Min. Elongation; Loads calculated using nom. wall)

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS
40.80
40.80
40.80
40.80
40.80
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
230.14
230.14
230.14
230.14
230.14
230.14
230.14

BARRELS
0.97
0.97
0.97
0.97
0.97
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
5.48
5.48
5.48
5.48
5.48
5.48
5.48

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined
by user. All data is for new tubing at minimum strength. * Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). See individual size sheets for additional wall thicknesses. 2-5/8", 2-7/8", and other sizes not shown are also available.

HS-70 GRADE* METRIC VALUES


DIMENSIONS
(mm)

NOMINAL
WEIGHT
Kg/m

O.D.
SPECIFIED

O.D.
(inches)

WALL
SPECIFIED

WALL
(inches)

WALL
MINIMUM

I.D.
CALCULATED

25.4

1.000

31.8

1.250

38.1

1.500

44.5

1.750

50.8

2.000

60.3

2.375

2.03
2.21
2.41
2.59
2.77
2.03
2.21
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
2.41
2.59
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
2.77
2.95
3.18
3.40
3.68
3.96
4.45
4.83
5.18
3.18
3.40
3.68
3.96
4.45
4.83
5.18

0.080
0.087
0.095
0.102
0.109
0.080
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.125
0.134
0.145
0.156
0.175
0.190
0.204

1.93
2.11
2.29
2.46
2.64
1.93
2.11
2.29
2.46
2.64
2.82
3.05
3.25
3.51
3.76
4.24
2.29
2.46
2.64
2.82
3.05
3.25
3.51
3.76
4.24
4.57
2.64
2.82
3.05
3.25
3.51
3.76
4.24
4.57
4.95
2.64
2.82
3.05
3.25
3.51
3.76
4.24
4.57
4.95
3.05
3.25
3.51
3.76
4.24
4.57
4.95

21.3
21.0
20.6
20.2
19.9
27.7
27.3
26.9
26.6
26.2
25.9
25.4
24.9
24.4
23.8
22.9
33.3
32.9
32.6
32.2
31.8
31.3
30.7
30.2
29.2
28.4
38.9
38.6
38.1
37.6
37.1
36.5
35.6
34.8
34.1
45.3
44.9
44.5
44.0
43.4
42.9
41.9
41.1
40.4
54.0
53.5
53.0
52.4
51.4 6
50.7
50.0

1.17
1.26
1.37
1.46
1.55
1.49
1.61
1.75
1.86
1.98
2.09
2.24
2.38
2.55
2.72
2.99
2.12
2.27
2.41
2.55
2.73
2.91
3.13
3.34
3.69
3.96
2.85
3.02
3.23
3.45
3.70
3.96
4.39
4.72
5.02
3.28
3.48
3.73
3.98
4.28
4.58
5.08
5.47
5.83
4.47
4.78
5.14
5.51
.13
6.61
7.05

TUBE LOAD BODY


(Newtons)

INTERNAL
PRESSURE (kPa)

TUBING AREA
(sq. cm)

TORSIONAL
YIELD
(N-m)

INTERNAL
CAPACITY

EXTERNAL
DISPLACEMENT

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

W/ MIN.
WALL

INTERNAL
MIN

YIELD

ULTIMATE

LITERS / METER

LITERS / METER

72,100
77,800
84,100
89,400
95,200
91,600
99,200
107,200
114,800
121,900
128,500
137,400
146,300
156,600
166,800
184,100
130,800
139,700
148,100
157,000
168,100
179,300
192,200
205,100
226,800
243,300
174,800
185,500
198,800
211,700
227,700
243,300
269,500
290,000
308,700
201,500
213,900
229,100
244,600
263,300
281,600
312,200
336,300
358,500
275,300
293,600
316,300
338,500
376,700
406,100
433,200

82,300
89,000
96,100
102,300
108,500
104,500
113,000
122,800
130,800
139,200
147,200
157,000
167,200
179,300
190,800
210,400
149,000
159,200
169,500
179,300
192,200
204,600
219,700
234,400
259,300
278,400
200,200
211,700
227,300
242,000
260,200
278,000
308,200
331,400
352,700
230,400
244,200
262,000
279,300
300,700
321,600
357,200
384,300
409,700
314,500
335,800
361,600
387,000
430,600
463,900
495,100

64,800
71,000
76,500
82,100
87,600
52,400
57,200
62,100
66,200
71,000
75,800
80,000
86,900
93,100
99,300
111,000
51,700
55,800
59,300
63,400
67,600
73,100
77,900
83,400
93,800
100,700
51,000
54,500
57,900
62,700
67,600
72,400
80,700
86,900
93,800
44,800
47,600
51,000
55,200
59,300
63,400
71,000
76,500
82,700
42,700
46,200
50,300
53,800
60,000
64,800
70,300

72,400
78,600
84,800
91,700
97,900
57,900
63,400
68,300
73,800
78,600
84,100
88,900
96,500
103,400
110,300
123,400
57,200
62,100
66,200
70,300
74,500
80,700
86,900
93,100
104,100
111,700
56,500
60,700
64,100
69,600
75,200
80,000
90,300
96,500
104,100
49,600
53,100
56,500
61,400
65,500
70,300
79,300
84,800
91,700
47,600
51,700
55,800
59,300
66,900
72,400
77,900

1.42
1.54
1.66
1.78
1.89
1.81
1.96
2.12
2.27
2.42
2.56
2.75
2.91
3.11
3.31
3.67
2.57
2.76
2.94
3.12
3.35
3.56
3.81
4.06
4.51
4.82
3.47
3.69
3.96
4.21
4.51
4.81
5.36
5.73
6.15
4.00
4.25
4.57
4.86
5.21
5.56
6.20
6.64
7.13
5.48
5.83
6.26
6.68
7.47
8.01
8.62

3.64
3.52
3.41
3.29
3.18
6.11
5.95
5.80
5.65
5.50
5.35
5.17
5.01
4.81
4.61
4.25
8.83
8.64
8.46
8.28
8.05
7.84
7.59
7.35
6.89
6.59
12.05
11.83
11.55
11.31
11.01
10.71
10.16
9.79
9.37
16.27
16.02
15.70
15.41
15.06
14.71
14.06
13.63
13.13
23.10
22.75
22.32
21.90
21.11
20.57
19.97

430
460
490
520
540
710
760
810
860
910
950
1,010
1,050
1,110
1,160
1,250
1,210
1,290
1,360
1,430
1,520
1,590
1,680
1,770
1,920
2,020
1,910
2,010
2,140
2,250
2,390
2,510
2,740
2,890
3,050
2,550
2,690
2,870
3,020
3,210
3,390
3,720
3,930
4,160
4,120
4,400
4,680
4,960
5,460
5,780
6,150

470
500
540
570
600
750
810
870
930
980
1,040
1,100
1,160
1,230
1,300
1,420
1,280
1,370
1,460
1,540
1,640
1,730
1,840
1,950
2,140
2,260
2,020
2,140
2,290
2,420
2,580
2,730
3,010
3,190
3,400
2,680
2,840
3,050
3,220
3,440
3,650
4,030
4,290
4,570
4,380
4,640
4,960
5,270
5,850
6,230
6,660

0.36
0.35
0.33
0.32
0.31
0.60
0.59
0.57
0.55
0.54
0.53
0.51
0.49
0.47
0.45
0.41
0.87
0.85
0.83
0.81
0.79
0.77
0.74
0.72
0.67
0.64
1.19
1.17
1.14
1.11
1.08
1.05
0.99
0.95
0.91
1.61
1.58
1.55
1.52
1.48
1.44
1.38
1.33
1.28
2.29
2.25
2.20
2.16
2.08
2.02
1.96

0.51
0.51
0.51
0.51
0.51
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.55
1.55
1.55
1.55
1.55
1.55
1.55
1.55
1.55
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.86
2.86
2.86
2.86
2.86
2.86
2.86

*Selected coiled tubing data


(70 Kpsi Min. Yield Strength; 80 Kpsi Min. Tensile Strength; 30 % Min. Elongation; Loads calculated using nom. wall)

Test pressure value equals 90% of internal yield pressure rating. Maximum working pressure is a function of tube condition and is determined
by user. All data is for new tubing at minimum strength. *Available as continuously milled tubing (CM) or conventional butt-welded tubing
sections (W). See individual size sheets for additional wall thicknesses. 2-5/8", 2-7/8", and other sizes not shown are also available.

Coiled Tubing Data .75" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

0.75

0.080
0.087
0.095
0.102
0.109

0.076
0.083
0.090
0.097
0.104

0.590
0.576
0.560
0.546
0.532

TUBE BODY LOAD


(Lbs.)

NOMINAL
WEIGHT
(lbs / ft)

0.574
0.618
0.666
0.708
0.748

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

11,800
12,700
13,700
14,500
15,400

13,500
14,500
15,600
16,600
17,600

12,400
13,500
14,600
15,700
16,700

13,800
15,000
16,200
17,400
18,500

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

INTERNAL
CAPACITY
per 1000 ft.

TORSIONAL
YIELD
(ft. / Lbs.)

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

0.75

0.076
0.083
0.090
0.097
0.104

0.161
0.174
0.187
0.199
0.211

0.281
0.268
0.255
0.243
0.231

166
176
186
195
203

183
196
209
220
231

14.20
13.54
12.79
12.16
11.55

0.34
0.32
0.30
0.29
0.27

GALLONS

22.95
22.95
22.95
22.95
22.95

BARRELS

0.55
0.55
0.55
0.55
0.55

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.000

0.080
0.087
0.095
0.102
0.109

0.076
0.083
0.090
0.097
0.104

0.840
0.826
0.810
0.796
0.782

TUBE BODY LOAD


(Lbs.)

NOMINAL
WEIGHT
(lbs / ft)

0.788
0.850
0.920
0.981
1.040

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

16,200
17,500
18,900
20,100
21,400

18,500
20,000
21,600
23,000
24,400

9,400
10,300
11,100
11,900
12,700

10,500
11,400
12,300
13,300
14,200

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

INTERNAL
CAPACITY
per 1000 ft.

TORSIONAL
YIELD
(ft. / Lbs.)

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

1.000

0.076
0.083
0.090
0.097
0.104

0.221
0.239
0.257
0.275
0.293

0.565
0.546
0.528
0.510
0.493

319
341
362
382
401

344
370
395
420
443

28.79
27.84
26.77
25.85
24.95

0.69
0.66
0.64
0.62
0.59

40.80
40.80
40.80
40.80
40.80

0.97
0.97
0.97
0.97
0.97

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.25" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

l.250

0.080
0.087
0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175

0.076
0.083
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167

1.090
1.076
1.060
1.046
1.032
1.018
1.000
0.982
0.960
0.938
0.900

NOMINAL
WEIGHT
(lbs / ft)

1.002
1.083
1.175
1.254
1.332
1.408
1.506
1.601
1.715
1.827
2.014

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

20,600
22,300
24,100
25,800
27,400
28,900
30,900
32,900
35,200
37,500
41,400

23,500
25,400
27,600
29,400
31,300
33,100
35,300
37,600
40,300
42,900
47,300

7,600
8,300
9,000
9,600
10,300
11,000
11,800
12,600
13,500
14,400
16,100

8,400
9,200
9,900
10,700
11,400
12,200
13,100
14,000
15,000
16,000
17,900

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

l.250

0.076
0.083
0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167

0.280
0.304
0.328
0.351
0.374
0.397
0.426
0.451
0.482
0.512
0.568

0.947
0.923
0.899
0.876
0.853
0.830
0.801
0.776
0.745
0.715
0.659

522
561
598
633
668
700
741
775
815
853
919

555
599
642
683
724
764
813
856
907
956
1,044

48.47
47.24
45.84
44.64
43.45
42.28
40.80
39.34
37.60
35.90
33.05

1.15
1.12
1.09
1.06
1.03
1.01
0.97
0.94
0.90
0.85
0.79

GALLONS

63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75
63.75

BARRELS

1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52
1.52

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.50" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.500

0.095
0.102
0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180

1.310
1.296
1.282
1.268
1.250
1.232
1.210
1.188
1.150
1.120

NOMINAL
WEIGHT
(lbs / ft)

1.429
1.527
1.623
1.719
1.840
1.960
2.104
2.245
2.483
2.665

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

29,400
31,400
33,300
35,300
37,800
40,300
43,200
46,100
51,000
54,700

33,500
35,800
38,100
40,300
43,200
46,000
49,400
52,700
58,300
62,600

7,500
8,100
8,600
9,200
9,900
10,600
11,300
12,100
13,600
14,600

8,300
9,000
9,600
10,200
11,000
11,700
12,600
13,500
15,100
16,200

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

1.500

0.090
0.097
0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180

0.399
0.428
0.456
0.484
0.520
0.552
0.590
0.629
0.699
0.746

1.368
1.340
1.311
1.283
1.247
1.215
1.177
1.139
1.068
1.021

893
949
1,003
1,055
1,120
1,175
1,242
1,305
1,416
1,486

947
1,011
1,074
1,135
1,211
1,278
1,358
1,436
1,577
1,668

70.02
68.53
67.06
65.60
63.75
61.93
59.74
57.58
53.96
51.18

1.67
1.63
1.60
1.56
1.52
1.47
1.42
1.37
1.28
1.22

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80
91.80

BARRELS

2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19
2.19

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 1.75" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

1.750

0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.532
1.518
1.500
1.482
1.460
1.438
1.400
1.370
1.342

NOMINAL
WEIGHT
(lbs / ft)

1.915
2.029
2.175
2.318
2.492
2.662
2.951
3.173
3.377

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

39,300
41,700
44,700
47,600
51,200
54,700
60,600
65,200
69,400

45,000
47,600
51,100
54,400
58,500
62,500
69,300
74,500
79,300

7,400
7,900
8,600
9,100
9,800
10,500
11,700
12,600
13,600

8,200
8,800
9,500
10,100
10,900
11,600
13,100
14,000
15,100

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

1.750

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.538
0.572
0.614
0.652
0.699
0.745
0.831
0.888
0.953

1.867
1.834
1.791
1.753
1.706
1.660
1.575
1.517
1.453

1,407
1,483
1,579
1,660
1,759
1,854
2,024
2,132
2,250

1,492
1,579
1,689
1,784
1,901
2,014
2,221
2,356
2,506

95.76
94.02
91.80
89.61
86.97
84.37
79.97
76.58
73.48

BARRELS

2.28
2.24
2.19
2.13
2.07
2.01
1.90
1.82
1.75

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95
124.95

BARRELS

2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97
2.97

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.00" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.000

0.109
0.116
0.125
0.134
0.145
0.156
0.175
0.190
0.204

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

1.782
1.768
1.750
1.732
1.710
1.688
1.650
1.620
1.592

NOMINAL
WEIGHT
(lbs / ft)

2.207
2.340
2.509
2.677
2.880
3.080
3.419
3.682
3.923

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

45,300
48,100
51,500
55,000
59,200
63,300
70,200
75,600
80,600

51,800
54,900
58,900
62,800
67,600
72,300
80,300
86,400
92,100

6,500
6,900
7,500
8,000
8,600
9,200
10,300
11,100
12,000

7,200
7,700
8,300
8,900
9,500
10,200
11,500
12,300
13,300

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

2.000

0.104
0.111
0.120
0.128
0.138
0.148
0.167
0.180
0.195

0.619
0.659
0.709
0.753
0.807
0.861
0.962
1.029
1.106

2.522
2.483
2.433
2.389
2.334
2.280
2.180
2.112
2.036

1,879
1,985
2,116
2,230
2,368
2,501
2,741
2,897
3,067

1,979
2,097
2,245
2,375
2,534
2,690
2,975
3,163
3,372

129.56
127.53
124.95
122.39
119.30
116.25
111.08
107.08
103.41

3.08
3.04
2.97
2.91
2.84
2.77
2.64
2.55
2.46

EXTERNAL
DISPLACEMENT
per 1000 ft.
GALLONS

163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20
163.20

BARRELS

3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89
3.89

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.375" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.375

0.125
0.134
0.145
0.156
0.175
0.190
0.204
0.224

0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.214

2.125
2.107
2.085
2.063
2.025
1.995
1.967
1.927

NOMINAL
WEIGHT
(lbs / ft)

3.011
3.215
3.462
3.706
4.122
4.445
4.742
5.159

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

61,900
66,000
71,100
76,100
84,700
91,300
97,400
106,000

70,700
75,500
81,300
87,000
96,800
104,300
111,300
121,100

6,300
6,700
7,300
7,800
8,700
9,400
10,200
11,100

7,000
7,500
8,100
8,600
9,700
10,500
11,300
12,400

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.375

0.120
0.128
0.138
0.148
0.167
0.180
0.195
0.214

0.850
0.904
0.970
1.035
1.158
1.241
1.335
1.453

3.580
3.527
3.460
3.395
3.272
3.189
3.095
2.977

3,072
3,243
3,452
3,655
4,025
4,266
4,533
4,855

3,229
3,421
3,656
3,886
4,313
4,595
4,913
5,301

184.24
181.13
177.37
173.64
167.31
162.38
157.86
151.50

4.39
4.31
4.22
4.13
3.98
3.87
3.76
3.61

230.14
230.14
230.14
230.14
230.14
230.14
230.14
230.14

5.48
5.48
5.48
5.48
5.48
5.48
5.48
5.48

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.625" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.625

0.134
0.145
0.156
0.175
0.190
0.204
0.224
0.250

0.128
0.138
0.148
0.167
0.180
0.195
0.214
0.240

2.357
2.335
2.313
2.275
2.245
2.217
2.177
2.125

NOMINAL
WEIGHT
(lbs / ft)

3.574
3.850
4.124
4.590
4.953
5.288
5.758
6.357

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

73,400
79,100
84,700
94,300
101,700
108,600
118,300
130,600

83,900
90,400
96,800
107,800
116,300
124,100
135,200
149,200

6,100
6,600
7,000
7,900
8,500
9,200
10,100
11,300

6,800
7,300
7,800
8,800
9,500
10,300
11,200
12,500

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.625

0.128
0.138
0.148
0.167
0.180
0.195
0.214
0.240

1.004
1.078
1.152
1.290
1.383
1.489
1.621
1.798

4.408
4.334
4.260
4.122
4.029
3.923
3.791
3.614

4,024
4,289
4,546
5,018
5,328
5,672
6,088
6,624

4,223
4,517
4,807
5,343
5,699
6,101
6,594
7,242

226.66
222.45
218.28
211.17
205.63
200.54
193.36
184.24

5.40
5.30
5.20
5.03
4.90
4.77
4.60
4.39

281.14
281.14
281.14
281.14
281.14
281.14
281.14
281.14

6.69
6.69
6.69
6.69
6.69
6.69
6.69
6.69

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

Coiled Tubing Data 2.875" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

2.875

0.156
0.175
0.190
0.204
0.224
0.250
0.280
0.300

0.148
0.167
0.180
0.195
0.214
0.240
0.270
0.288

2.563
2.525
2.495
2.467
2.427
2.375
2.315
2.275

NOMINAL
WEIGHT
(lbs / ft)

4.541
5.059
5.462
5.834
6.358
7.026
7.779
8.271

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

93,300
103,900
112,200
119,800
130,600
144,300
159,800
169,900

106,600
118,800
128,200
136,900
149,200
164,900
182,600
194,200

6,400
7,300
7,800
8,400
9,200
10,300
11,600
12,300

7,200
8,100
8,700
9,400
10,300
11,500
12,900
13,700

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

2.875

0.148
0.167
0.180
0.195
0.214
0.240
0.270
0.288

1.268
1.421
1.524
1.642
1.789
1.987
2.210
2.341

5.224
5.071
4.968
4.850
4.703
4.505
4.282
4.151

5,536
6,122
6,508
6,939
7,463
8,142
8,872
9,283

5,825
6,483
6,922
7,418
8,029
8,835
9,722
10,233

268.01
260.12
253.98
248.31
240.32
230.14
218.66
211.17

6.38
6.19
6.05
5.91
5.72
5.48
5.21
5.03

337.24
337.24
337.24
337.24
337.24
337.24
337.24
337.24

8.03
8.03
8.03
8.03
8.03
8.03
8.03
8.03

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new tubing at specified minimum
strengths.

Coiled Tubing Data 3.5" O.D.


HS-70 CM* or HS-70 W**
DIMENSIONS
(Inches)
O.D.
SPECIFIED

WALL
SPECIFIED

WALL
MINIMUM

I.D.
CALCULATED

3.500

0.175
0.190
0.204
0.224
0.250
0.280
0.300

0.167
0.180
0.195
0.214
0.240
0.270
0.288

3.150
3.120
3.092
3.052
3.000
2.940
2.900

NOMINAL
WEIGHT
(lbs / ft)

6.230
6.733
7.199
7.857
8.699
9.653
10.278

TUBE BODY LOAD


(Lbs.)

INTERNAL PRESSURE
(psi)

YIELD
MINIMUM

TENSILE
MINIMUM

HYDRO TEST
90%

INTERNAL
YIELD MIN.

128,000
138,300
147,900
161,400
178,700
198,300
211,100

146,200
158,100
169,000
184,400
204,200
226,600
241,300

6,000
6,400
7,000
7,600
8,500
9,600
10,200

6,600
7,200
7,700
8,500
9,500
10,600
11,300

HS-70 CM* or HS-70 W**


DIMENSIONS
(Inches)

TUBING AREA
(sq. in.)

TORSIONAL
YIELD
(ft. / Lbs.)

INTERNAL
CAPACITY
per 1000 ft.

EXTERNAL
DISPLACEMENT
per 1000 ft.

O.D.
SPECIFIED

WALL
MINIMUM

W / WALL
MIN.

INTERNAL
MIN.

YIELD

ULTIMATE

GALLON

BARRELS

GALLONS

BARRELS

3.500

0.167
0.180
0.195
0.214
0.240
0.270
0.288

1.749
1.877
2.025
2.209
2.458
2.740
2.906

7.872
7.744
7.596
7.412
7.163
6.881
6.715

9,364
9,979
10,671
11,519
12,629
13,840
14,533

9,817
10,500
11,274
12,234
13,510
14,928
15,751

404.84
397.16
390.07
380.04
367.20
352.66
343.13

9.64
9.46
9.26
9.05
8.74
8.40
8.17

499.80
499.80
499.80
499.80
499.80
499.80
499.80

11.90
11.90
11.90
11.90
11.90
11.90
11.90

* Continuously milled tubing.


** Butt-welded tube sections.

HS-70 CM or HS-70 W

www.tenaris.com
October 2009. Tenaris. All rights reserved

Tube Body Load: Yield &


Tensile Minimums calculated on Specified Wall.
Hydrostatic Test Pressure:
All completed coiled tubing
strings shall be hydrostatic
pressure tested prior to
shipping. The hydrostatic
test pressure shall be lesser
of 90% of the theoretical
burst yield strength or
17,500 psi or 120,700 kPa

(unless specifically agreed


between purchaser and
manufacturer).
Internal Yield: Internal
Pressure to cause yielding
using Minimum Yield
Strength and Minimum
Wall Thickness.
Maximum Working Pressure is a function of tube
condition and is determined by the user.

Torque Values Calculated


Using Minimum Wall Thickness and Minimum Yield
Strength.
Other sizes/wall thickness
available on request.
Above data is for new
tubing at specified minimum strengths.

You might also like